This architectural program document outlines requirements for facilities at the Attwater Prairie Chicken National Wildlife Refuge. The scope of work includes construction of new indoor and outdoor exhibit spaces totaling 2,530 square feet, with a $300,000 budget for exhibitry design, construction and installation. A 1,100 square foot biology laboratory is also required, along with administrative offices and conference rooms totaling 1,690 square feet. Additional needs comprise covered parking for staff and visitors, a 6,650 square foot maintenance shop renovation, and expansion of a 7,250 square foot equipment storage barn. The related federal contract opportunity is for design/build services for a maintenance facility and administration building at the Attwater Prairie Chicken NWR, issued by the U.S. Fish and Wildlife Service.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DISPLAY AREA
NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL
1250 Indoor Exhibit Display of birds/plants on the Refuge 1250
750 Outdoor Exhibit Area with Interpretive panels and space to congregate 750
300 Public Restrooms Outdoor accessible public restrooms 300
Subtotal 2300
Total Usable Space Apply 1.1 Circulation Factor 2530
Specific requirements:
FWS will provide an exhibitry budget for planning purposes.
DB shall contract with a reputable exhibitry consultant for design and construction and installation of the exhibits .
Exibits may not be limited to only the exhibit space.
Special Note: The outdoor exhibit area shall include a covered space of 750 square feet for people to congregate, access to outdoor restrooms and a bus loading and unloading area. The budget for the design, construction and installation of all materials, fixtures and features is $300,000(three hundred thousand dollars) for the both indoor and outdoor exhibitry.
BIOLOGY LABORATORY AREA
NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUB-TOTAL AREA TOTAL
400 Biology Laboratory Laboratory 400 440
150 Biologist Office Office 150 165
130 Asst. Biologist Office Office 130 143
120 Intern/GIS Office Office 120 132
200 Storage Specimen Storage 200 220
Subtotal 1000
Total Usable Space Apply 1.1 Circulation Factor 1100
ADMINISTRATIVE/VISITOR CENTER BUILDING
ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 1
Specific requirements:
Chemical resistant tops on built in casework for lab provide power in specimen storage for freezer
Specimen storage area needs to have 220 power for deep freezer, climate control to prevent freezer overheating and backup power in case of an outage
CONFERENCE ROOM AREA
NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL
237 Conference Room Meetings 450 585
94 Breakroom Lunch room 250 325
97 Information Technology Rm Computer Room 100 130
99 Storage 1 General Storage 100 130
97 Storage 2 General Storage 100 130
147 Restrooms 300 390
Subtotal 1,300
Total Usable Space Apply 1.3 Circulation Factor 1690
Specific requirements:
Phone/data in conf room and breakroom
Sink in breakroom
Stand alone backup cooling in IT room
ADMINISTRAIVE AREA
NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL
233 Refuge Manager's Office Office 175 227.5
229 Asst. Refuge Manager's Office Office 150 195
127 Admin. Office Office 150 195
ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 2
127 Copy/Mail Room Office 100 130
198 Friends' Office Office 150 195
100 Restrooms 1 100 130
90 Restrooms 2 90 117
Subtotal 915
Total Usable Space Apply 1.3 Circulation Factor 1190
Specific requirements: phone and data
Phone and data in all offices and mail room
3 data/phone ports in each office
COVERED PARKING
NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL
1500 Staff Parking 1 8 Staff Vehicles 1500 1500
1500 Staff Parking 2 8 Government Vehicles 1500 1500
Subtotal 3000
Total Usable Space No Circulation Factor included 3000
Specific requirements:
Furnish and Install Electric Vehicle Charging Stations for three (3) vehicles to be located under the covered staff parking areas
NON COVERED PARKING
NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL
15000 Visitor Parking Area Paved parking area for visitors 15000 15000
Subtotal 15000
Total Usable Space No Circulation Factor included 15000
Specific requirements:
COVERED PARKING
PUBLIC PARKING
ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 3
Furnish and Install Electric Vehicle two (2) Charging Stations in the VC/Admin Public Parking Area.
Provide 2 RV spaces
Net area is a recommendation. Actual size shall be determined by occupant load served.
NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL
6650 Maintenance Shop Existing Building - to be renovated 6650 6650
Replace HVAC Units Replace five HVAC units with three high efficiency units and relocate along NW side of building
Replace all exterior doors and door frames
(SE corner of the Maintenance shop building shown here)
Replace five air handlers Replace five air handlers (propane) with three high efficiency electric units in the NW corner of the building
Install interior access doors Install interior access doors to the current oil and pesticide storage rooms
Remove interior wall Remove interior wall between SW bays and wood shop
Install roll up doors (SW Corner) Install two full-height roll up doors in SW corner bays
Install roll up doors (SE Corner)
Install two full height roll-up doors in the SE corner bay (what is now the wood shop) to provide for pull-through access in West bays.
Remove old wash room Remove old wash room and relocate pressure washer into SE corner of building
Replace rollup doors Two full-height roll up doors to be moved to the SW end of the building and replaced with shorter doors. 6650
Total Usable Space No Circulation Factor included 6650
Specific requirements:
New HVAC system
Renovate toilet rooms and offices
Addition of a new rollup door
Replacement of existing vehicle lift and, pressure washer
ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 4
MAINTENANCE SHOP BUILDING
Replace exterior doors
New LED lighting
Replacement of all doors and windows
All rollup doors to be 16ft high except where shorter height is requested.
NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL
6250 Vehicle Storage Existing Building - to be renovated. 6250 6250
Add concrete apron around the equipment barn.
Refurbish “YCC” portion of equipment barn to include storage loft, insulate and add heat/air conditioning.
Add insulation, heat and air conditioning and a storage loft in
YCC portion of the equipment barn
1000 Storage
Add pesticide storage, eyewash station, outdoor wash rack with drainage containment and enclosed parking with power receptacles for three UTV’s to the east end of the equipment storage building. New covered addition for ATV/UTV Storage
1000 1000
Subtotal 7250
Total Usable Space No Circulation Factor included 7250
Specific requirements:
Insulation installation in YCC portion (+/- 1250 sf)
New HVAC stem in YCC portion
Addition of a storage loft
New eyewash/shower station
New air compressor and piping provide power and lighting for ATV/UTV Storage
New LED lighting
Special Note: See attached pictures further description of scope of work at the Equipment Storage Shed.
EQUIPMENT STORAGE BARN
NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL
3240 Storage
Existing Vehicle/Equipment Storage to be renovated. Add concrete floors, enclose the East two bays and install roll-up doors in the equipment shed
3240 3240
3360 Storage
Vehicle/Equipment Storage addition. Add an extension/addition to the equipment shed that provides enclosed parking for five
FWS vehicles, covered parking for four farm implements and a shade covering for the fuel pumps
3360 3360
Subtotal 6600
Total Usable Space No Circulation Factor included 6600
Specific requirements:
8 new 16' high rollup doors on addition
Extended roof line over fueling station
New concrete slab in last 2 bays of existing building
Replacement of existing vehicle lift and, pressure washer
New LED lighting/power provide pedestrian door to addition
2 new rollup doors in last 2 bays of existing building
Special Note: See attached pictures further description of scope of work at the Equipment Storage Shed
ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 5
EQUIPMENT STORAGE SHED