This architectural program document outlines requirements for facilities at the Attwater Prairie Chicken National Wildlife Refuge. The scope of work includes construction of new indoor and outdoor exhibit spaces totaling 2,530 square feet, with a $300,000 budget for exhibitry design, construction and installation. A 1,100 square foot biology laboratory is also required, along with administrative offices and conference rooms totaling 1,690 square feet. Additional needs comprise covered parking for staff and visitors, a 6,650 square foot maintenance shop renovation, and expansion of a 7,250 square foot equipment storage barn. The related federal contract opportunity is for design/build services for a maintenance facility and administration building at the Attwater Prairie Chicken NWR, issued by the U.S. Fish and Wildlife Service.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DISPLAY AREA

NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL

1250 Indoor Exhibit Display of birds/plants on the Refuge 1250

750 Outdoor Exhibit Area with Interpretive panels and space to congregate 750

300 Public Restrooms Outdoor accessible public restrooms 300

Subtotal 2300

Total Usable Space Apply 1.1 Circulation Factor 2530

Specific requirements:

FWS will provide an exhibitry budget for planning purposes.

DB shall contract with a reputable exhibitry consultant for design and construction and installation of the exhibits .

Exibits may not be limited to only the exhibit space.

Special Note: The outdoor exhibit area shall include a covered space of 750 square feet for people to congregate, access to outdoor restrooms and a bus loading and unloading area. The budget for the design, construction and installation of all materials, fixtures and features is $300,000(three hundred thousand dollars) for the both indoor and outdoor exhibitry.

BIOLOGY LABORATORY AREA

NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUB-TOTAL AREA TOTAL

400 Biology Laboratory Laboratory 400 440

150 Biologist Office Office 150 165

130 Asst. Biologist Office Office 130 143

120 Intern/GIS Office Office 120 132

200 Storage Specimen Storage 200 220

Subtotal 1000

Total Usable Space Apply 1.1 Circulation Factor 1100

ADMINISTRATIVE/VISITOR CENTER BUILDING

ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 1

Specific requirements:

Chemical resistant tops on built in casework for lab provide power in specimen storage for freezer

Specimen storage area needs to have 220 power for deep freezer, climate control to prevent freezer overheating and backup power in case of an outage

CONFERENCE ROOM AREA

NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL

237 Conference Room Meetings 450 585

94 Breakroom Lunch room 250 325

97 Information Technology Rm Computer Room 100 130

99 Storage 1 General Storage 100 130

97 Storage 2 General Storage 100 130

147 Restrooms 300 390

Subtotal 1,300

Total Usable Space Apply 1.3 Circulation Factor 1690

Specific requirements:

Phone/data in conf room and breakroom

Sink in breakroom

Stand alone backup cooling in IT room

ADMINISTRAIVE AREA

NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL

233 Refuge Manager's Office Office 175 227.5

229 Asst. Refuge Manager's Office Office 150 195

127 Admin. Office Office 150 195

ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 2

127 Copy/Mail Room Office 100 130

198 Friends' Office Office 150 195

100 Restrooms 1 100 130

90 Restrooms 2 90 117

Subtotal 915

Total Usable Space Apply 1.3 Circulation Factor 1190

Specific requirements: phone and data

Phone and data in all offices and mail room

3 data/phone ports in each office

COVERED PARKING

NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL

1500 Staff Parking 1 8 Staff Vehicles 1500 1500

1500 Staff Parking 2 8 Government Vehicles 1500 1500

Subtotal 3000

Total Usable Space No Circulation Factor included 3000

Specific requirements:

Furnish and Install Electric Vehicle Charging Stations for three (3) vehicles to be located under the covered staff parking areas

NON COVERED PARKING

NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL

15000 Visitor Parking Area Paved parking area for visitors 15000 15000

Subtotal 15000

Total Usable Space No Circulation Factor included 15000

Specific requirements:

COVERED PARKING

PUBLIC PARKING

ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 3

Furnish and Install Electric Vehicle two (2) Charging Stations in the VC/Admin Public Parking Area.

Provide 2 RV spaces

Net area is a recommendation. Actual size shall be determined by occupant load served.

NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL

6650 Maintenance Shop Existing Building - to be renovated 6650 6650

Replace HVAC Units Replace five HVAC units with three high efficiency units and relocate along NW side of building

Replace all exterior doors and door frames

(SE corner of the Maintenance shop building shown here)

Replace five air handlers Replace five air handlers (propane) with three high efficiency electric units in the NW corner of the building

Install interior access doors Install interior access doors to the current oil and pesticide storage rooms

Remove interior wall Remove interior wall between SW bays and wood shop

Install roll up doors (SW Corner) Install two full-height roll up doors in SW corner bays

Install roll up doors (SE Corner)

Install two full height roll-up doors in the SE corner bay (what is now the wood shop) to provide for pull-through access in West bays.

Remove old wash room Remove old wash room and relocate pressure washer into SE corner of building

Replace rollup doors Two full-height roll up doors to be moved to the SW end of the building and replaced with shorter doors. 6650

Total Usable Space No Circulation Factor included 6650

Specific requirements:

New HVAC system

Renovate toilet rooms and offices

Addition of a new rollup door

Replacement of existing vehicle lift and, pressure washer

ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 4

MAINTENANCE SHOP BUILDING

Replace exterior doors

New LED lighting

Replacement of all doors and windows

All rollup doors to be 16ft high except where shorter height is requested.

NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL

6250 Vehicle Storage Existing Building - to be renovated. 6250 6250

Add concrete apron around the equipment barn.

Refurbish “YCC” portion of equipment barn to include storage loft, insulate and add heat/air conditioning.

Add insulation, heat and air conditioning and a storage loft in

YCC portion of the equipment barn

1000 Storage

Add pesticide storage, eyewash station, outdoor wash rack with drainage containment and enclosed parking with power receptacles for three UTV’s to the east end of the equipment storage building. New covered addition for ATV/UTV Storage

1000 1000

Subtotal 7250

Total Usable Space No Circulation Factor included 7250

Specific requirements:

Insulation installation in YCC portion (+/- 1250 sf)

New HVAC stem in YCC portion

Addition of a storage loft

New eyewash/shower station

New air compressor and piping provide power and lighting for ATV/UTV Storage

New LED lighting

Special Note: See attached pictures further description of scope of work at the Equipment Storage Shed.

EQUIPMENT STORAGE BARN

NET AREA(SF) FUNCTION EXPANDED DESCRIPTION AREA SUBTOTAL AREA TOTAL

3240 Storage

Existing Vehicle/Equipment Storage to be renovated. Add concrete floors, enclose the East two bays and install roll-up doors in the equipment shed

3240 3240

3360 Storage

Vehicle/Equipment Storage addition. Add an extension/addition to the equipment shed that provides enclosed parking for five

FWS vehicles, covered parking for four farm implements and a shade covering for the fuel pumps

3360 3360

Subtotal 6600

Total Usable Space No Circulation Factor included 6600

Specific requirements:

8 new 16' high rollup doors on addition

Extended roof line over fueling station

New concrete slab in last 2 bays of existing building

Replacement of existing vehicle lift and, pressure washer

New LED lighting/power provide pedestrian door to addition

2 new rollup doors in last 2 bays of existing building

Special Note: See attached pictures further description of scope of work at the Equipment Storage Shed

ATTWATER PRAIRE CHICKEN NWR ARCHITECTURAL PROGRAM PAGE 5

EQUIPMENT STORAGE SHED

File details come from the government source that posted it. Updated .