This technical specification document from the Indiana Department of Environmental Management (IDEM) Office of Water Quality (OWQ) outlines analytical requirements for laboratory services related to fish tissue analysis. The document details the general requirements for analysis parameters, detection levels, and analytical methods that must be followed according to Tasks 1-11 in Attachment H6, with specific reference to analytical methods in Attachment H7.

The specification establishes requirements for Method Detection Limits (MDLs), Contract Required Quantitation Limits (CRQLs), and analytical procedure modifications. MDLs must be determined according to 40 CFR Part 136, Appendix B, with contractors required to report the largest MDL value when using multiple instruments. CRQLs are calculated using laboratory reported MDLs or method MDLs multiplied by 3.18, though contractors may suggest higher CRQLs with proper documentation. Any modifications to analytical procedures must receive prior IDEM/OWQ approval and undergo a conditional approval process requiring detailed documentation including MDL determination, Initial Precision and Recovery determination, and side-by-side comparison runs.

View the file

Other files for this state and local contract opportunity

Other files attached to Laboratory Analytical Services for Fish TissuesBid Documents, newest first.
File Type Posted
81029 Pre-Proposal Conference Slides.pptx PPTX presentation
81029Addendum 1.docx DOCX document
81029AttA1 - IVOSB_08222023.docx DOCX document
81029AttB Professional-Services-Contract-Template.docx DOCX document
81029AttE - Business Proposal updated.docx DOCX document
81029AttF - Technical Proposal Template.doc DOC document
81029AttH1 - Technical Specifications.docx DOCX document
81029AttH3 - Technical Specifications - QA QC Criteria.doc DOC document
81029AttH7 - Technical Spec - Test Method References.docx DOCX document
81029AttI - Pre-proposal Network Form_08242021.docx DOCX document
81029AttJ - Attestation Form_09132022 (2).docx DOCX document
81029AttM IntenttoRespondForm.docx DOCX document
81029Addendum 2.docx DOCX document
81029AttA - MWBE_08222023.docx DOCX document
81029AttH2 - Technical Specifications - Definitions.doc DOC document
81029AttH6 - Technical Specifications - Tasks List1.docx DOCX document
81029AttB Professional-Services-Contract-Template.docx DOCX document
81029AttH1 - Technical Specifications.docx DOCX document
81029AttH3 - Technical Specifications - QA QC Criteria.doc DOC document
81029AttH7 - Technical Spec - Test Method References.docx DOCX document
81029AttM IntenttoRespondForm.docx DOCX document
81029 Pre-Proposal Conference Slides.pptx PPTX presentation
81029Addendum 1.docx DOCX document
81029AttG - QandA_.xlsx XLSX spreadsheet
81029AttH5 - Technical Specifications - Reporting.doc DOC document
81029AttI - Pre-proposal Network Form_08242021.docx DOCX document
81029AttK - Electronic Data Reporting Standards.doc DOC document
RFP Boilerplatev3updated.pdf PDF
81029AttA - MWBE_08222023.docx DOCX document
81029AttA1 - IVOSB_08222023.docx DOCX document
81029AttF - Technical Proposal Template.doc DOC document
81029AttG - QandA_.xlsx XLSX spreadsheet
81029AttH1 - Technical Specifications.docx DOCX document
81029AttH2 - Technical Specifications - Definitions.doc DOC document
81029AttJ - Attestation Form_09132022 (2).docx DOCX document
81029AttK - Electronic Data Reporting Standards.doc DOC document
RFP Boilerplate.pdf PDF
81029AttA - MWBE_08222023.docx DOCX document
81029AttC - Indiana Economic Impact Form (1).xls XLS spreadsheet
81029AttD - Cost Proposal Template.xlsx XLSX spreadsheet
81029AttE - Business Proposal.docx DOCX document
81029AttH - Reference Check.docx DOCX document
81029AttH3 - Technical Specifications - QA QC Criteria.doc DOC document
81029AttH4 - Tech Spec - Methods & Analytical Parameters.doc DOC document
81029AttH6 - Technical Specifications - Tasks List1.docx DOCX document
81029AttM IntenttoRespondForm.docx DOCX document
81029AttA1 - IVOSB_08222023.docx DOCX document
81029AttH5 - Technical Specifications - Reporting.doc DOC document
81029AttH7 - Technical Spec - Test Method References.docx DOCX document
81029AttI - Pre-proposal Network Form_08242021.docx DOCX document
Show all 50

Laboratory Analytical Services for Fish TissuesBid Documents has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFP-25-81029

Attachment H4

Technical Specifications Methods and Analytical Parameters

A. General Requirements

Analysis will be performed for the parameters listed in the tables for Tasks 1 through 11 of Attachment H6 – Task Lists, to a detection level equal to or less than the one given in the table, and using the analytical methods referenced in Attachment H7- Test Method References. Contractors must meet parameter update requirements as specified in Attachment H1, Technical Requirements, Section A.3. All instrumental, sample preparatory, and QA/QC procedures must be met in accordance with the method and Technical Specifications. Any alterations of an analytical method, parameter list, or QA/QC item must be approved by the responsible IDEM/OWQ section.

B.

Method Detection Limits (MDL) MDLs must be determined in accordance with 40 CFR Part 136, Appendix B, at a frequency specified in the method or Attachment H3 – Quality Assurance/Quality Control Data Criteria, Table 1, whichever more frequent. If Contractors utilize multiple instruments for a procedure, Contractors shall report the largest MDL value for an analyte obtained from a group of instruments. Contractors must list the instrument identification number or some other form of identifier with the MDL value obtained from that instrument.

C.

Contract Required Quantitation Limits (CRQL) CRQLs are listed in Attachment H6 – Task Lists and utilize the higher value of laboratory reported MDLs or method MDLs times a factor of 3.18 as recommended in USEPA wastewater compliance guidance. Typically the values are rounded up after applying this multiplier.

The IDEM/OWQ realizes these CRQLs may present some difficulty in achieving for some parameters. IDEM/OWQ will take any suggested CRQL or reporting limit under advisement.

Contractors may suggest higher CRQLs. Contractors must provide the reporting limit they can achieve for each parameter the Contractor desires to increase. MDL studies must be provided in accordance with the appendices. Alternative CRQLs must be approved by IDEM/OWQ.

Alternative CRQLs must be submitted in paper and disk formats. Disk format must be an ASCII delimited file of the format:

Parameter name, Chem Abstracts No, method number, suggested CRQL, units

Contractors must report the actual detection or reporting limits used for an analytical procedure, in an analytical report. These limits can be the current operating or reporting limits for a Contractor’s facility, for a procedure. Do not report the CRQLs listed in the Task Lists in an analytical report, unless these are the detection limits. Contractors may use a single reporting limit for all instruments potentially utilized for an analytical method. Vendors must notify IDEM/OWQ of changes in reporting limits.

D.

Analytical Procedure Modifications Many analytical methods allow changes in separatory methods, columns, extraction techniques, and preconcentration procedures. The modification must provide analyte selectivity and detector response greater than or equal to the unmodified procedure.

Modifications outside of those specified in the method must be approved by IDEM/OWQ prior to utilization on IDEM/OWQ samples.

Modifications may be approved on a conditional basis until sufficient sample analyses are conducted (at least thirty (30) actual samples) under production conditions.

To receive conditional approval for a procedure modification the Vendor must provide the following:

1. Sample and QA/QC numbers, prep dates and times, analytical sequence, and names analyst(s) and/or technician(s).

2. MDL determination.

3. Initial Precision and Recovery (IPR) determination or (study)

4. Side by side comparison runs without modifications.

5. All sample preparation data.

6. Initial, intermediate, and final volumes for each step.

7. Instrumental conditions, column types, detectors, flow rates, or other operational parameters.

8. Raw data.

9. QA/QC showing accuracy and precision.

Permanent approval may be granted by IDEM/OWQ after reviewing results of production analytical runs with the modification(s).

RFP-25-81029

Technical Specifications H4

File details come from the government source that posted it. Updated .