80KSC021R0029 J-I Pad 39B Outrigger Guidelines.pdf

PDF 278 KB Posted

Attached to
Mobile Launcher 1 (ML-1) Emergency Egress System (EES) Conveyance Federal contract opportunity
Solicitation number
80KSC021R0029
Issued by
National Aeronautics and Space Administration Kennedy Space Center

About this file

This file provides guidelines and drawings for outrigger pads to support a mobile launcher at Kennedy Space Center. It also describes a federal contract opportunity for installation of an emergency egress conveyance system on Mobile Launcher 1.

The opportunity solicitation is for implementation of all tasks to install a new conveyance system, including structural modifications, fabrication and installation of platforms, modification to existing structures, basket assemblies, a PLC-based safety control system, braking system, wire ropes, hoisting and control systems. The scope also includes testing, verification and validation of the new and modified installations. The solicitation number is 80KSC021R0029 and is issued by the National Aeronautics and Space Administration Kennedy Space Center for installation on Mobile Launcher 1. Requests for controlled documents require verification of vendor certification by the Defense Logistics Agency Joint Certification Program.

View the file

Other files for this federal contract opportunity

Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P.T.C.R. BUILDING

SUBSTRUCTURE INFLUENCE ZONE

(RED)

CRAWLER WAY - CATACOMBS

STRUCTURE (BLUE)

APRON SLAB (GREEN)

GENERAL NOTES:

1. ALL PADS SHALL HAVE ADEQUATE STIFFNESS TO DISTRIBUTE OUTRIGGER LOADS UNIFORMLY

ACROSS THE ENTIRE PAD AREA

2. PADS SHALL SIT FLAT ON CONCRETE SURFACE, STACK DISTRIBUTION PADS OVER COMPLIANT

MATERIAL SUCH AS PLYWOOD OR HARD RUBBER PAD TO ACCOMODATE SURFACE UNEVENNESS

3. MAINTIAN A MINIMUM 5'-0" CLEAR AREA AROUND OUTRIGGER PADS, UON

4. NO RESTRICTION ON OUTRIGGER LOADS <30 KIP, MINIMUM 2'X2' CRANE FEET AND 8'-0" c.c. SPACING

(USE OF MINIMUM DISTRIBUTION PAD RECOMMENDED)

5. GRATING SURFACES HAVE NOT BEEN EVALUATED, AVOID OUTRIGGER LOADING

6. FOR STEEL PADS, CONSIDER PLACING PLYWOOD SHEET BETWEEN FLOAT AND PLATE TO REDUCE

POTENTIAL FOR SLIDING

7. FOR OPERATIONS EXCEEDING THESE GENERAL GUIDELINES, SUBMIT DESIRED OPERATION TO

TOSC ANALYSIS FOR CASE-BY-CASE REVIEW

MAX OUTRIGGER REACTION

260 KIP

200 KIP

160 KIP

130 KIP

100 KIP

75 KIP

50 KIP

MIN DISTRIBUTION AREA

10'X10'

8'X8' 7'X7' 6'X6' 5'X5' 4'X4' 3'X3'

MAX OUTRIGGER REACTION

260 KIP

140 KIP

75 KIP

MIN DISTRIBUTION AREA

4'X4' 3'X3' 2'X2'

MAX OUTRIGGER REACTION

80 KIP

70 KIP

50 KIP

MIN DISTRIBUTION AREA

6'X6' 4'X4' 3'X3'

H.P.G. STORAGE BATTERY AREA

SUBSTRUCTURE INFLUENCE ZONE

(RED)

12'-0"

'-0

'-0

12'-0"

12'-0"

'-0

'-0

CRANE OUTRIGGER GUIDLINES PAD B SURFACE

7/18/2019 FOR PRELIMINARY USE

8/9/2019 INITIAL RELEASE

MAINTAIN A MINIMUM 12'-0" CLEAR AREA

AROND OUTRIGGER PADS IN

SUBSTRUCTURE INFLUENCE ZONES