J-2_PAT006-Drawings.pdf
PDF 2 MB Posted
- Attached to
- Amendment0003
- Solicitation number
- 70Z082-18-B-PAT006-00
About this file
J-2 - Drawings
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C O
C O
C O
C O
C O
C O
C O
C O
C O
C O
C O
C O
C O
C O
BRUSH
TAXIWAY
PARKING APRON
CONC PARKING APRON
RIP-RAP
DENSE TREES
PARKING
DENSE TREES
DENSE TREES
CONC
VEH
IC
LE STORAGE
AREA
TANNER WILLIAMS ROAD
MARINER DRIVE
MARLIN STREET
TANNER WILLIAMS ROAD
DETENTION POND
MARLIN STREET
GREAT HOUSE DRIVE
BRUSH
TAXIWAY
PARKING APRON
CONC PARKING APRON
RIP-RAP
DENSE TREES
PARKING
DENSE TREES
DENSE TREES
CONC
VEH
IC
LE STORAGE
AREA
MARINER DRIVE
MARLIN STREET
TANNER WILLIAMS ROAD
DETENTION POND
MARLIN STREET
GREAT HOUSE DRIVE
W
IN
D S O C
S
IG
N
W
IN
D S O C
S
IG
N
C O N C
CONC
C O N C
CONC
C O U R T
TE
N N
IS
C T
TE
N N
IS
C T
TE
N N
IS
C T
TE
N N
IS
C T
P O O L
POOL
H O O P
H O O P
C O U R T
B A S K E
TB
A
LL V
O
LLE
Y B A
LL
C O U R T
TE
N N
IS
C T
TE
N N
IS
C T
TE
N N
IS
C T
TE
N N
IS
C T
P O O L
POOL
H O O P
H O O P
C O U R T
B A S K E
TB
A
LL V
O
LLE
Y B A
LL
O P E N
S
TO
R A G E
O P E N
S
TO
R A G E
D E N S E
TR
E E S
D E N S E
TR
E E S
D E N S E
TR
E E S
D E N S E
TR
E E S
B R U S H
B R U S H
B R U S H
D E N S E
TR
E E S
D E N S E
TR
E E S
B R U S H
D E N S E
TR
E E S
D E N S E
TR
E E S
D E N S E
TR
E E S
D E N S E
TR
E E S
D E N S E
TR
E E S
D E N S E
TR
E E S
B R U S H
B R U S H
B R U S H
D E N S E
TR
E E S
D E N S E
TR
E E S
B R U S H
D E N S E
TR
E E S
D E N S E
TR
E E S
TA
N K
C A N O P Y
B
LE
A C H E R S
TA
N K
TR
TR
TR
CANOPY
C
AN
O P Y
TA
N K
TA
N K
CANOPY
C
AN
O P Y
C
AN
O P Y
TA
N K
TR
CANOPY
CANOPY
CANOPY
CANOPY
CANOPY
CANOPY
TA
N K
TA
N K
C O N C
C O N C
TA
N K
TE
R R A C E
TE
R R A C E
C O N C
C O N C
H A N G A R
TA
N K
C A N O P Y
B
LE
A C H E R S
TA
N K
TR
TR
TR
CANOPY
C
AN
O P Y
TA
N K
TA
N K
CANOPY
C
AN
O P Y
C
AN
O P Y
TA
N K
TR
CANOPY
CANOPY
CANOPY
CANOPY
CANOPY
CANOPY
TA
N K
TA
N K
C O N C
C O N C
TA
N K
TE
R R A C E
TE
R R A C E
C O N C
C O N C
H A N G A R
TAN
N
ER
W
ILLIAM
S
R O
AD
TAN
N
ER
W
ILLIAM
S
R O
AD
FOSTER ROAD
TAN
N
ER
W
ILLIAM
S
R O
AD
TAN
N
ER
W
ILLIAM
S
R O
AD
FOSTER ROAD
C O N C
APPROX/LOC
C O N C
APPROX/LOC
A P P R O X
LO
C
A P P R O X
LO
C
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
RAMP
PARK
IN
G
C O N C
P A R K
IN
G
P A R K
IN
G
C O N C
P A R K
IN
G
PARKING
A S P H
P A R K
IN
G
A P R O N
U N P A V E D
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
PARKING
P A R K
IN
G
P A R K
IN
G
PAR
K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
RAMP
PARK
IN
G
C O N C
P A R K
IN
G
P A R K
IN
G
C O N C
P A R K
IN
G
PARKING
A S P H
P A R K
IN
G
A P R O N
U N P A V E D
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
P A R K
IN
G
PARKING
P A R K
IN
G
P A R K
IN
G
PAR
K
IN
G
R
IP
R A P
R
IP
R A P
R
IP
R A P
R
IP
R A P
R
IP
R A P
R
IP
R A P
R
IP
R A P
R
IP
R A P
R
IP
R A P
R
IP
R A P
A210
DISCIPLINE:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
F - FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T - TELECOMM
SHEET
NUMBER
WITHIN
SERIES:
SERIES NUMBER:
0 - GENERAL
1 - PLANS
2 - ELEVATIONS
3 - SECTIONS
4 - LARGE-SCALE VIEWS
5 - DETAILS
6 - SCHEDULES & DIAGRAMS
8 - USER DEFINED
9 - 3D REPRESENTATIONS
ANNOTATION CALLOUTS/DRAWING SYMBOLS
INTERIOR
ELEVATION
A101
SIM
SECTION
A101
Ref
A101
Ref
EXTERIOR
ELEVATION
PLAN NORTH
NORTH ARROW w/
TRUE NORTH
INDICATION
SPOT ELEVATION
Name Elevation
FLOOR LEVEL &
NAME
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SIM
PLAN, BLOW-
UP DETAIL
PLATE NUMBER
WHERE
SECTION/DETAIL IS
DRAWN
A# WINDOW TYPE "A" AND
MARK "#"
# SHEET KEYNOTE
SUPPLY
DUTWORK
RETURN
DUTWORK
EXHAUST
DUTWORK
EXHAUST FAN
(EF)
MAKE UP AIR
UNIT (MAU)
ATC BASE MAP
N.T.S.
NORTH
o
MISSISSIPPI
ALABAMA98
o
CENTER ENTRANCE
AVIATION TRAINING
U.S. COAST GUARD
o p p10
MOBILE
BAY
GULF OF MEXICO
MOBILE
MUNICIPAL
AIRPORT
TANNER
W
ILLIAMS RD.
p
FLORIDA
ALABAMA
PROJECT
LOCATIONLOCATION MAP
N.T.S.
NORTH
VIC INITY M AP
ROADCODY
ZIEGLER RD
ROAD
ROAD
OLD SHELL RD.
BOULEVARD
AIRPORT
N.T.S.
SCHILLINGER
TANNER
NORTH
MAIN G ATE ENTRANC E
U.S. CO AST GUARD
AVIATIO N TRAINING C ENTER
MUNIC IPAL AIRPORT
BATES FIELD
WILLIAMS
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DEPARTMENT OF HOMELAND SECURITY
UNITED STATES COAST GUARD
AVIATION TRAINING CENTER
8501 TANNER WILLIAMS ROAD
MOBILE, ALABAMA
PLOT SCALE: D SIZE
SHEET OF
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
As indicated
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
DESIGNED BY: EOH
EDITED BY: RAC
S18684280G-001
G-001
Cover Sheet
DRAWN BY: EOH
CHECKED BY: NCP
CDR P F Bosma
GENERAL
IN HOUSE
S18684280G-001
PROJECT NUMBER:684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
JAN 2018
ID DATE DESCRIPTION
3 01NOV 30% Deliverable 4 15NOV 90% Review 5 5DEC 100% Deliverable
Facilities Engineering Building
Main Entrance To Base
Project Location
DRAWING INDEX
SHT NO Drawing Title Sheet
G-001 Cover Sheet 1 M101 Existing HVAC Flr, Roof and ISO Plan 2 M102 HVAC Demolition Plan 3 M103 Proposed HVAC Plan 4 M601 HVAC Schedule 5 M602 DDC ARCH & AHU1 Control Diagrams 6 M603 AHU2 & MAU Sequence of Operation 7 E101 Existing HVAC Electrical Plan 8 E102 Proposed HVAC Electrical Plan 9 E601 Electrical Panel Schedule 10
SUMMARY OF WORK
SHEET NUMBERING SYSTEM
GENERAL ARCHITECTURAL SCOPE OF WORK:
1. Roofing contractor will be onsite before and during installation of Rooftop (RT) Make‐up Air Unit (MAU). The roofer will modify existing roof curb opening, install flashing and repair any damage due to installation. Upon completion roofer will install roof coating material.
GENERAL MECHANICAL SCOPE OF WORK
1. Remove the existing RT indirect fired MAU, ventilation blower, duct work, wiring and controls. Inspect and modify existing roof curbs to ensure it will accommodate the new air conditioned RT MAU. Provide and Install the new larger MAU.
2. Install new metal duct work from the new MAU and connect to the existing supply duct. Modify existing AHU1 and AHU2 ductwork for OA modulating damper.
3. Install new electrical circuit sized to support the new air conditioned MAU and new control wiring and sensors.
Ensure the new air conditioning unit is bonded to a ground connection point.
Strip Shop
Composite Repair Storage
Composite Repair
Hallway 1
Break Room
Office
Women
Paint Booth
Paint Mix Room
Men
HAZ Waste Storage
Mechanical Room
Chemical Storage
Hallway 3
Hallway 2
Paint Booth Room
AHU1 Composite Repair
AHU2 RM 5,6,7,8,11,15,16
MAU1 Paint Booth
MAU2 Paint Booth Rm & Mix Rm
MAU3 Storage Rooms
MAU4 Strip Shop
MAU-4
EF-2
MAU-2
MAU-1
AHU1CU-1
AHU2
CU-2
EF-4
EF-5
EF-6
EF-3
EF-1
Exhaust Air
Outside Air
Return Air
Supply Air
MAU-4
MAU-3
CU-1
CU-2
AHU2
AHU1
MAU-1 MAU-2
EF-2
EF-6
EF-5
EF-4
EF-3
EF-1
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DESIGNED BY:
DRAWN BY:
EDITED BY:
CHECKED BY:
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
SHEET OF
PLOT SCALE: D SIZE
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
1/8" = 1'-0"
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
EOH
RAC
S18684280M101
M101
Existing HVAC Flr, Roof and ISO Plan
EOH
NCP
CDR P F Bosma
MECHANICAL
IN HOUSE
S18684280M101
JAN 2018
1/8" = 1'-0" C1
EXISTING HVAC FLOOR AND ZONE PLAN
A1
EXISTING HVAC ISOMETERIC (3D) PLAN
1/8" = 1'-0" C4
EXISTING CEILING AND ROOF PLAN
ID DATE DESCRIPTION
2 25OCT 10% Deliverable 3 01NOV 30% Deliverable 4 15NOV 90% Review 5 20DEC 100% Deliverable
GENERAL NOTES DUCT COLOR LEGEND
ZONE NAME COLOR LEGEND
SCALE AND ORIENTATION
1. The contractor is to notify the COR if conditions differing from those stated are uncovered in the demolition process.
2. Coordinate architectural and structural dimensions prior to fabrication and assembly of any RT MAU.
3. Contractor will be working next to an active air field and shall keep the job free of debris and make daily cleanup to the satisfaction of the COR.
4. Contractor shall be responsible for the protection of all existing roof top components (gas line and lightning protection system, modified bitumen roofing) while performing the specified work.
5. Contractor shall field verify all dimensions in field prior construction. Notify engineer of any signifcant discrepancies on drawings.
6. Contractor shall make required adjustments to system components as necessitated by actual field conditions at no additional cost to government. Report any discrepancies between the drawings and actual field conditions to the COR before construction begins.
04 8 16268
SCALE: 1/8"=1'-0"
PLAN
N
O R
TH
ABBREVIATIONS
AHU Air Handling Unit AI Analog Input AO Analog Output BAS Building Automation System BI Binary Input BO Binary Output BTUH Brtish Thermal Units / Hour CFM Cubic Feet per Minute COR Contracting Officer Rep DA Discharge Air DDC Direct Digital Control DI Digital Input DO Digital Output DP(S) Differential Pressure (Sensor) DX Direct Expansion EAT Entering Air Temperature EC Equipment Controller ECM Electronically Commutated Motor EER Energy Efficiency Ratio EF Exhaust Fan ES End Switch FC Field Controller GUI Graphical User Interface I/O Input Output LAT Leaving Air Temperature LON Local Operating Network MUA Make-up Air Unit MO Manual Override NC Normally Closed NO Normally Open OA Outside Air OAT Outside Air Temperature OS Occupancy Sensor RA Return Air RH Relative Humidity RPM Revolutions Per Minute RTU Roof Top (Unit) SA Supply Air SAT Supply Air Temperature SFM Supply Fan (Motor) SP Static Pressure ST Starter SS Start Stop T Temperature or Thermostat VD Volume Damper
MAU-3
A1 M102
LH
LH
MAU-4
MAU-3
AHU1
AHU2
20,22,24
MAU-1
MAU-2
EF-6EF-5
EF-3
EF-4
EF-1
M102
32LH07
L5X5X7/16
W6X12
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DESIGNED BY:
DRAWN BY:
EDITED BY:
CHECKED BY:
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
SHEET OF
PLOT SCALE: D SIZE
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
As indicated
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
EOH
RAC
S18684280M102
M102
HVAC Demolition Plan
EOH
NCP
CDR P F Bosma
MECHANICAL
IN HOUSE
S18684280M102
JAN 2018
ID DATE DESCRIPTION
3 01NOV 30% Deliverable 4 15NOV 90% Review 5 5DEC 100% Deliverable
3/16" = 1'-0" C1
CEILING & ROOF DEMOLITION PLAN
1/4" = 1'-0"
M102
C1 A1 Section - Roof Paint Booth MAU & Frame
GENERAL DEMOLITION NOTES
SCALE AND ORIENTATION
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
SCALE: 3/16"=1'-0"
48 8
PLAN
N
O R
TH
SHEET KEYNOTES
1. Building will be occupied during construction.
Contractor is to coordinate demolition to not disturb owner/client daily tasks.
2. The drawings are intended to show the extent of demolition. The drawings are not to be construed as indicating all existing conditions.
Contractor is responsible to verify existing conditions and dimensions.
3. Refer to mechanical, electrical, drawings for demolition of respective equipment.
4. All demolition work shall be coordinated with new work. Plumbing (rooftop gas lines are not depicted on drawings).
5. Existing lightning protection components air terminals (rods), conductor (cable), mounting plates, etc, attached to the existing equipment to be removed and temporarily supported in order to demolish and re-install new equipment. For code issues consult w/COR
6. All demolished material not designated for salvage to be removed and disposed of off of ATC by contractor.
7. Plan for 5 percentage of existing membrane to be replaced due to new equipment dimensional difference from existing.
8. Comply with roofing manufacturers requirements for tie-in of new roof componets to existing. Current roof is warrantied under Garland Company, Inc
9. All wood material is to be pressure treated.
10. After award value engineering will be considered IAW contract clause.
1 Remove and salvage roof EF. Replace with new EF. Coordinate with mechanical schedule to confirm capacity.
2 Remove and salvage MAU. Coordinate disposition with COR
4 Remove and dispose of MAU and curb.
5 Existing metal frame to remain. New unit weight not to exceed 8,000 pound
3 This unit is controlled by paint booth control panel. Contractor to coordinate control wiring removal with existing Bananza Paint Booth controls
4 4
6 Replace EF. After contract award value engineering change proposal will be considered.
1/4" = 1'-0"
M102
C1 1 Section AHU-2 Ductwork
7 Connection point for new OA Damper
A3 M103
A1 M103
110'-0"
MAU-4
MAU-3
AHU1
AHU2
20,22,24
MAU-1
'-8
EF-1
EF-3
M103
EF-5
'-4
13'-2 15/16"
NEW CURB
EQUIPMENT
OR FAN
ENCLOSURE
NEW FIBER CANT
NEW MODIFIED
BITUMEN STRIP
FLASHING
NEW CURB
TAPERED
INSULATION
NEW MODIFIED
BITUMEN ROOF
EXISTING
ROOF
DECK
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DESIGNED BY:
DRAWN BY:
EDITED BY:
CHECKED BY:
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
SHEET OF
PLOT SCALE: D SIZE
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
As indicated
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
EOH
RAC
S18684280M103
M103
Proposed HVAC Plan
EOH
NCP
CDR P F Bosma
MECHANICAL
IN HOUSE
S18684280M103
JAN 2018
ID DATE DESCRIPTION
2 25OCT 10% Deliverable 3 01NOV 30% Deliverable 4 15NOV 90% Review 5 20DEC 100% Deliverable
3/16" = 1'-0" C1
CEILING AND ROOF PLAN
3/16" = 1'-0"
M103
C1 A3 Section - Proposed Paint Booth MAU
3/16" = 1'-0"
M103
C1 A1 Section Strip Shop MAU
GENERAL CONSTRUCTION NOTES
SCALE AND ORIENTATION
SCALE: 3/16"=1'-0"
48 8
PLAN
N
O R
TH
SHEET KEYNOTES
N.T.S.
Typical Existing Roof Curb
1. Owner will occupy the construction area of building 24/7 during demolition and/or new construction.
2. Contractor shall notify the contracting officer of existing conditions that necessitate altering framing or connections shown on the drawings.
3. Refer to architectural and electrical plans for additional information and requirements.
4. The contractor shall maintain the operation of the existing gas plumbing systems all system shut downs shall be coordinated with the contracting officer prior to any shut-downs.
5. Drawings are schematic in nature and are intended to specify basic design parameters.
contractor shall field verify existing conditions. contractor is responsible for the layout and installation of the systems in conformance with local codes and international plumbing and mechanical codes.
6. Existing roof is a modified bitumen roofing system on rigid insulation on metal deck.
Current roof is warrantied under Garland Company, Inc.
7. Reinstall lightning protection system once roof coating and equipment are installed.
8. Gas piping not shown in drawings.
1 New MAU IAW Schedule and Specifications
2 New EF 3 New curb in accordance with specifications and equipment manufacturers guidelines
4 Upon completion of work, roofer is to provide a cool white 10 mil polyurethane coating compatible with existing warranty.
5 Existing equipment rack to support new
MAU
1 1
6 BASE BID: Replace Gas Fire MAU with Gas Fire MAU IAW Schedule & Spec's
7 BASE BID: Install outside air motorized damper on top of existing return ductwork located on roof. Trane Model:
CSAA012UBG00
8 BASE BID: Provide manufacturers retrofit to allow for ~15% outside air to existing AHU (Balance with EF-5) Trane Model:
YSC060E4EMA1N
6 6
4 TYP4 TYP
4 TYP 4 TYP
5 9 BID OPTION 1 - PAINT BOOTH: Replace Gas Fired MAU with Gas Fired Air Condition MAU IAW equipment schedule
10 BID OPTION 2 - STRIP ROOM: Replace Gas Fired MAU with Gas Fired Air Condition MAU IAW equipment schedule
3/16" = 1'-0"
M103
C1 3 Alternative Damper
9. Contractor is to account for the transition between the new units and existing ductwork.
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DESIGNED BY:
DRAWN BY:
EDITED BY:
CHECKED BY:
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
SHEET OF
PLOT SCALE: D SIZE
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
EOH
RAC
S18684280M601
M601
HVAC Schedule
EOH
NCP
CDR P F Bosma
MECHANICAL
IN HOUSE
S18684280M601
JAN 2018
ID DATE DESCRIPTION
2 25OCT 10% Deliverable 3 01NOV 30% Deliverable 4 15NOV 90% Review 5 5DEC 100% Deliverable
Building Make-up Air
MARK REMARKS COOLING MBH EER
PRESSURE
DROP (FT HD.) Description EAT HEATING MBH HP CFM
VOLTAGE/
PH
MAU-1 Old 0.0 Btu/h - 1.00 in-wg Modular Outdoor Down Discharge Direct Fired Heater 29 °F 704000.0 Btu/h 10 12000 CFM 480/3 MAU-1 New 300000.0 Btu/h 11 1.00 in-wg Modular Outdoor Down Discharge Direct Fired Heater- Cooling 29 °F 800000.0 Btu/h 10 12000 CFM 480/3 MAU-3 Old 0.0 Btu/h Modular Outdoor Down Discharge Direct Fired Heater 29 °F 17500.0 Btu/h 1 1530 CFM 480/3 MAU-3 New 0.0 Btu/h Modular Outdoor Down Discharge Direct Fired Heater 29 °F 175000.0 Btu/h 1 1530 CFM 480/3 MAU-4 Old 0.0 Btu/h Modular Outdoor Down Discharge Direct Fired Heater 29 °F 350000.0 Btu/h 4200 CFM 480/3 MAU-4 New 144000.0 Btu/h 11 1.00 in-wg Modular Outdoor Down Discharge Direct Fired Heater- Cooling 29 °F 168000.0 Btu/h 2000 CFM 480/3
Existing Building Exhaust Air Unit
MARK CFM REMARKS
EF-1 4400 CFM Balance new CFM to 2200, Interlock with operation of MAU-4
EF-2 12600 CFM
EF-3 2140 CFM Interlock operation with new outdoor air damper installed in AHU-1 roof mounted return ductwork
EF-4 1600 CFM
EF-5 710 CFM Balance with AHU-2 new outdoor damper
EF-6 1350 CFM
HVAC Cooling Coils Mark CFM REMARKS
AHU1 2050 CFM Provide 100% outside air when EF-3 is on AHU2 1515 CFM Provide 50% outside air when EF-5 is on
SQ
B
POWERS
SQB
H
G
POWERS
XD
GENERAL NOTES:
REFER TO EQUIPMENT SCHEDULES AND PLAN DRAWINGS FOR SPECIFIC QUANTITIES AND LOCATIONS OF DEVICES AND
EQUIPMENT.
NEW ARCHITECTURE CONTROL DIAGRAM
ET
H
ER
NE
T B
AC
KB
ON
E
IN
ST
AL
LE
D
IN
C
ON
DU
IT
REMOTE
DIAL-UP
ACCESS
BANANZA
INTERNET
WORKSTATION
EC
MAU-4
ROOF PLAN
FACILTIES ENGINEERING BLDG S10
COMPOSITE BUILDING S18
MECHANICAL ROOM
EC
EF-1
ST
MAU-3
EC
AHU-1
EC
EF-3
EC
AHU-2
ST
MAU-2
EC
EF-5
ST
EF-6
ST
EF-4
EC
MAU-1
ST
EF-2
PAINT BOOTH ROOM
FIELD
CONTROLLERCONTROLLER
OL'S
B
A
M
M
L3L2L1
LEGEND Point Description I/O
OAT` Outside air temperature AI SAT Supply air temperature AI ----- Return air temperature AI T Space temperature AI DSP Duct static pressure AI ESS Exhaust fan start/stop BO EMO Exhaust fan Manual Override BI SSS Supply fan start/stop BO SFM Supply Fan Motor status BI ----- Enthalpy controller BI OVD Outside air Volume Dampers AO EVD Exhaust air Volume Dampers AO DX Air cooled condensing 2 stage BO/BO GH Gas Heat BO OS Occupancy Sensor BI ----- Differential Pressure Sensor ----- Freezestat ----- High limit static pressure switch ----- Supply air duct smoke detector ----- External shutdown cmmd frm BAS ----- System graphic
XFMR 2-XFMR 1- XFMR 3-
COMPONENT PANEL_
SPACE SENSORS
OA SA
CONTROL TRANSFORMERS MOUNTED IN COMPONENT PANEL.
MOTION SENSOR AND POWER SUPPLY WIRING DIAGRAM
100 VA100 VA 100 VA
NC
OAT SAT
LINE
PWR
120V
24VDC
RELAY COM
N.O.
N.C.
CONTROL OUT
+24V
MAN. SWITCH
COMMON
COMMON
DI 2
TO
ROOM
OS
MOTION SENSOR
OS
MOTION SENSOR
SFM
OVD
120V
PROOF
ON/OFF
DSP NC
EVD
120V
DAMPER & DAMPER MOTOR PROVIDED
BY OTHERS.
REPLAY LOCATED AT FAN STARTER
T EF
M/O
CS-1
NC
NO
RE-5
AE-1
PROOF
EXISTING TRANSFORMER LOCATED
ON/OFF R
CONTROLLER TRANSFORMER
FROM EXISTING
24 VAC
1 2
S1 S2
S3
S4 S5
S6
STARTER
AT CONTROLLER.
RELAY LOCATED AT FAN STARTER.
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DESIGNED BY:
DRAWN BY:
EDITED BY:
CHECKED BY:
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
SHEET OF
PLOT SCALE: D SIZE
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
As indicated
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
EOH
RAC
S18684280M602
M602
DDC ARCH & AHU1 Control Diagrams
EOH
NCP
CDR P F Bosma
MECHANICAL
IN HOUSE
S18684280M602
JAN 2018
ID DATE DESCRIPTION
4 15NOV 90% Review 5 5DEC 100% Deliverable
CONTROL DEVICE LEGEND
AHU-1 SEQUENCE OF OPERATION & CONTROL
AHU-1 Composite Repair
CONTROLLER
AHU Air Handling Unit AI Analog Input AO Analog Output BAS Building Automation System BI Binary Input BO Binary Output BTUH Brtish Thermal Units / Hour CFM Cubic Feet per Minute COR Contracting Officer Rep DA Discharge Air DDC Direct Digital Control DI Digital Input DO Digital Output DP(S) Differential Pressure (Sensor) DX Direct Expansion EAT Entering Air Temperature EC Equipment Controller ECM Electronically Commutated Motor EER Energy Efficiency Ratio EF Exhaust Fan ES End Switch FC Field Controller GUI Graphical User Interface I/O Input Output LAT Leaving Air Temperature LON Local Operating Network MUA Make-up Air Unit MO Manual Override NC Normally Closed NO Normally Open OA Outside Air OAT Outside Air Temperature OS Occupancy Sensor RA Return Air RH Relative Humidity RPM Revolutions Per Minute RTU Roof Top (Unit) SA Supply Air SAT Supply Air Temperature SFM Supply Fan (Motor) SP Static Pressure ST Starter SS Start Stop T Temperature or Thermostat VD Volume Damper
1. Building DDC provides system on-off signal based on time schedule.
2. Building DDC system shall signal unit operation upon receiving status on from room occupancy sensor.
3. In occupied mode EF3 and AHU1 fans shall run. Interlock EF3 to run only when AHU1 damper is open.
4. In normal occupied mode EF and OA volume dampers shall modulated for 300 CFM.
5. AHU1 EC shall cycle compressor and gas heat as required to maintain supply air temperature and RH setpoint.
6. In unoccupied mode EF3 and AHU1 volume dampers shall close. AHU1 fan shall cycle with compressor and gas burner to maintain average room setback temperature at 55 degree heating 80 degree cooling.
7. Unoccupied mode override may be achieved by signal from DDC system or manually from room occupancy sensor. Duration of override shall be 20 minutes.
8. EF3 manual override shall modulate volume dampers to supply fan CFM interlock with AHU1 volume damper.
POWERS
H
G
XD
SQ
B
0 10
POWERS
XD
H
G
XD
OL'S
B
A
M
M
L3L2L1
OL'S
B
A
M
M
L3L2L1
XFMR 2-XFMR 1- XFMR 3-
COMPONENT PANEL_
Move Space Sensor to Hallway
SA
CONTROL TRANSFORMERS MOUNTED IN COMPONENT PANEL.
MOTION SENSOR AND POWER SUPPLY WIRING DIAGRAM
100 VA100 VA 100 VA
LINE
PWR
120V
24VDC
RELAY COM
N.O.
N.C.
CONTROL OUT
+24V
MAN. SWITCH
COMMON
COMMON
DI 2
TO
ROOM
OS
MOTION SENSORS
OS
MOTION SENSOR
REPLAY LOCATED AT FAN STARTER
T
OS OS
ROOM ROOM
OA
OAT SAT
SFM
PROOF
ON/OFF
DSP
RAT
NC
OVD
120V
XFMR 2-XFMR 1- XFMR 3-
COMPONENT PANEL_
SPACE SENSORS
OA SA
CONTROL TRANSFORMERS MOUNTED IN COMPONENT PANEL.
MOTION SENSOR AND POWER SUPPLY WIRING DIAGRAM
100 VA100 VA 100 VA
OAT
BZ-50
120V
24VDC
RELAY COM
N.O.
N.C.
CONTROL OUT
+24V
MAN. SWITCH
COMMON
COMMON
DI 2
TO
ROOM
OS
MOTION SENSOR
MS
MOTION SENSOR
SFM
PROOF
ON/OFF DPS
DAMPER & DAMPER MOTOR PROVIDED
BY OTHERS.
REPLAY LOCATED AT FAN STARTER
SAT
CS-1
NC
NO
RE-5
AE-1
PROOF
EXISTING TRANSFORMER LOCATED
ON/OFF R
CONTROLLER TRANSFORMER
FROM EXISTING
24 VAC
1 2
S1 S2
S3
S4 S5
S6
STARTER
AT CONTROLLER.
RELAY LOCATED AT FAN STARTER.
LEGEND Point Description I/O
OAT` Outside air temperature AI SAT Supply air temperature AI RAT Return air temperature AI T Space temperature AI DSP Duct static pressure AI OVD Outside air Volume Dampers AO SSS Supply fan start/stop BO SFM Supply Fan Motor status BI ----- Enthalpy controller BI DX Air cooled condensing 2 stage BO/BO GH Gas Heat BO OS Occupancy Sensor BI ----- Differential Pressure Sensor ----- Freezestat ----- High limit static pressure switch ----- Supply air duct smoke detector ----- External shutdown cmmd frm BAS ----- System graphic
CS-1
NC
NO
RE-5
AE-1
PROOF
EXISTING TRANSFORMER LOCATED
ON/OFF R
CONTROLLER TRANSFORMER
FROM EXISTING
24 VAC
1 2
S1 S2
S3
S4 S5
S6
STARTER
AT CONTROLLER.
RELAY LOCATED AT FAN STARTER.
LEGEND Point Description I/O
OAT` Outside air temperature AI SAT Supply air temperature AI ----- Return air temperature AI T Space temperature AI DSP Duct static pressure AI ESS Exhaust fan start/stop BO SSS Supply fan start/stop BO SFM Supply Fan Motor status BI ----- Enthalpy controller BI DX Air cooled condensing 2 stage BO/BO GH Gas Heat 2 stage BO/BO OS Occupancy Sensor BI ----- Differential Pressure Sensor ----- Freezestat ----- High limit static pressure switch ----- Supply air duct smoke detector ----- External shutdown cmmd frm BAS ----- System graphic
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DESIGNED BY:
DRAWN BY:
EDITED BY:
CHECKED BY:
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
SHEET OF
PLOT SCALE: D SIZE
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
As indicated
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
EOH
RAC
S18684280M603
M603
AHU2 & MAU Sequence of Operation
EOH
NCP
CDR P F Bosma
MECHANICAL
IN HOUSE
S18684280M603
JAN 2018
ID DATE DESCRIPTION
4 15NOV 90% Review 5 5DEC 100% Deliverable
AHU-2 SEQUENCE OF OPERATION & CONTROL
MAU-4 SEQUENCE OF OPERATION & CONTROL
1. Building DDC provides system on-off signal based on time schedule.
2. In occupied mode air handling unit fan shall run and AHU2 internal controls shall cycle compressor and gas heat as required to maintain supply air temperature setpoint.
Setback temperature at 55 degree heating 80 degree cooling
3. In normal occupied mode OVD shall be closed.
When EF5 is on OVD shall modualte to EF5 capacity.
4. DDC shall monitor Return air temperature, office 1 OS, office 2 OS and breakroom OS occupancy, and determine heating or cooling mode operation, and occupied/unoccupied setting.
5. Unoccupied mode override may be achieved by signal from base DDC system or manually at the room sensor. Duration of override shall be 1.5 hour.
AHU-2 Offices, Hallway, Break Room etc
MAU4 – Strip Room
1. Building DDC provides system on-off signal based on time schedule.
2. In occupied mode EF1 and MAU4 fan shall run. Interlock EF1 to run only when MAU4 Fan runs.
3. MAU4 internal controls shall cycle compressor and gas heat as required to maintain supply air temperature setpoint.
4. In unoccupied mode EF1 and MAU4 fan shall not run. Unoccupied mode setpoints will be 40 degree heating and 85 degree cooling.
5. Unoccupied mode override may be achieved by signal from base DDC system or manually from room occupancy sensor.
6. Duration of override shall be 30 minutes.
7. Building DDC system shall signal unit operation upon receiving status on from Room occupancy sensor.
OTHER SEQUENCE OF OPERATION & CONTROL
MAU1
1. All operations of MAU1 and EF2 are to be solely controlled by paint booth controller Bananza controller. 1-800.255.3416 www.bananza.com.
A Bananza panel controls the operation of the rooftop unit. Desired heating and cooling setpoints are programmed via the panel. Fan operation is determined by the position of the fan “ON-AUTO” switch.
MAU2 & EF6 – Paint Booth Rm & Paint Mix Rm
1. Building DDC provides system on-off signal based on time schedule.
MAU3 – Storage
2. Building DDC provides system on-off signal based on time schedule.
CONTROLLER
CONTROLLER
MDP
T3PP-1
T2LP-1
LP-1TS
PP-2
PP-1
MS EF-2
240V
MAU-4
DP LP-2 MS AHU-1
MS AHU-2
MS EF-4
MS MAU-2
MS EF-3
EF-3
EF-4
EF-1
EF-2
EF-6
EF-5
AHU1
AHU2
ST MAU-4ST EF-1
MS MAU-3
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DESIGNED BY:
DRAWN BY:
EDITED BY:
CHECKED BY:
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
SHEET OF
PLOT SCALE: D SIZE
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
3/16" = 1'-0"
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
EOH
RAC
S18684280E101
E101
Existing HVAC Electrical Plan
EOH
NCP
CDR P F Bosma
ELECTRICAL
IN HOUSE
S18684280E101
JAN 2018
ID DATE DESCRIPTION
4 15NOV 90% Review 5 5DEC 100% Deliverable
3/16" = 1'-0"
Electrical Demolition Plan
GENERAL ELECTRICAL NOTES
SCALE AND ORIENTATION
SCALE: 3/32"=1'-0"
816 16
SCALE: 3/16"=1'-0"
48 8
PLAN
N
O R
TH
SHEET KEYNOTES
1. Plan interruptions with COR in advance of requesting interruptions
2. The drawings are intended to show the extent of the demolition. They are not to be construed as indicating all existing conditions. The contractor is responsible to verify existing conditions and dimensions.
1 Remove and dispose of motor starter 2 Replace motor starter
3 Remove mark time fan switch for paint mixing room
4 Remove restroom light and fan exhaust switch and replace with OS
5 Replace existing HVAC control panel with New
MDP
T3PP-1
T2LP-1
LP-1TS
PP-2
PP-1
MS EF-2
240V
MAU-4
DP LP-2 MS AHU-1
MS AHU-2
MS EF-4
MS MAU-2
MS EF-3
EF-3
EF-4
EF-1
EF-2
EF-6EF-5
AHU1
AHU2
ST MAU-4ST EF-1
E102 A3
A1
MAU-1
MS MAU-3
1' -1
/8
'-9
5/
8"
'-0
/8
1' -1
/8
1'-1 3/8" 9'-1 5/16" 12'-11 5/8" 1'-1 3/8"1/16" 5'-0 1/4" 0"1'-1 3/8" 16'-8 13/16" 5'-10 3/16" 7 5/8" 7'-9 3/16" 8'-3 7/16" 1'-1 3/8"1/8" 4'-11 7/8" 0"1'-1 3/8" 15'-3" 7 5/8" 7'-2 3/16" 8'-10 7/16" 1'-1 3/8"
(MS MAU-3) - (1)
3-#10, 1-#10, 1-#10
MAU-3
(MDP) - (8,10,12)
3-#10, 1-#10, 1-#10
(ST MAU-4) - (1)
3-#10, 1-#10, 1-#10
LP-1 DP LP-2
PP-1
ST MAU-4
ST EF-1
MS MAU-3
LP-1 / 75
kVA
PP-1 / 45
kVA
MS AHU-1
MS AHU-2
MS EF-4
MS MAU-2
MDP
T3PP-1T2LP-1
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DESIGNED BY:
DRAWN BY:
EDITED BY:
CHECKED BY:
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
SHEET OF
PLOT SCALE: D SIZE
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
As indicated
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
EOH
RAC
S18684280E102
E102
Proposed HVAC Electrical Plan
EOH
NCP
CDR P F Bosma
ELECTRICAL
IN HOUSE
S18684280E102
JAN 2018
ID DATE DESCRIPTION
4 15NOV 90% Review 5 5DEC 100% Deliverable
3/16" = 1'-0" B1
FIRST FLOOR PLAN
GENERAL ELECTRICAL NOTES
SCALE AND ORIENTATION
SCALE: 3/16"=1'-0"
48 8
SCALE: 3/8"=1'-0"
24 4
PLAN
N
O R
TH
SHEET KEYNOTES
3/8" = 1'-0"
E102
B1 A1 Mechanical Room West
3/8" = 1'-0"
E102
B1 A3 Mechanical Room North
MAU-3 - Reuse conduit and wiring . Delete starter if unit is packaged with start.
MAU-4 Depending on the way the selected system is wired make one and two runs to MDP. Provide appropriate as builds.
1 Replace old honeywell control panel with new control panel. Run new control wiring.
2 Replace motor starter 3 Remove mark time fan switch for paint mixing room 4 Remove restroom light and fan exhaust switch and replace with OS
DISCIPLINE/SHT NO
PROJECT NUMBER DRAWING NUMBER
APPROVING OFFICER DATE
PROJ ENGR CNSTR MGR COTR
AVIATION TRAINING CENTER
MOBILE AL
EOH NCP RAC
SHEET TITLE
SAM DESIGN P/N:
CAD FILE NAME:
Facilities Engineering Mobile/AL
Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil
U.S. COAST GUARD
U.S. COAST GUARD
8501 TANNER WILLIAMS ROAD
MOBILE AL 36608
FACILITIES ENGINEERING
ATC MOBILE
SCALE:
ISSUE
DESIGNED BY:
DRAWN BY:
EDITED BY:
CHECKED BY:
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
SHEET OF
PLOT SCALE: D SIZE
D :\E ng in ee rin g\
-R ep ai r_
M ec ha ni ca l &
H
VA
C S ys te m s_
C om po si te B ld g
(S
)\6
0-
D W
G -R ep ai r_ M ec ha ni ca l & H
VA
C
S ys te m s_ C om po si te
B ld g (S
).r vt
684280
Repair_Mechanical & HVAC Systems_Composite Bldg (S18)
EOH
RAC
S18684280E601
E601
Electrical Panel Schedule
EOH
NCP
CDR P F Bosma
ELECTRICAL
IN HOUSE
S18684280E601
JAN 2018
ID DATE DESCRIPTION
4 15NOV 90% Review 5 5DEC 100% Deliverable
Replace old "Strip Tank" breaker (7,9,11) and wiring with New MAU-4 Condensor2 power. Replace old "Old Degreaser" breaker (8,10,12) and wiring with New MAU-4 Condensor1 power.
Notes:
Legend:
Total Amps: 278 A 278 A 259 A Total Load: 76274 VA 76274 VA 71774 VA
41 -- -- -- 20000... 0 VA -- -- -- 42
39 -- -- -- 20000... 0 VA -- -- -- 40
37 T2LP-1 125 A 3 20000... 0 VA 3 200 A Spare - 0ld 100 HP compressor 38 35 Space -- -- 0 VA 6333... -- -- -- 36 33 Space -- -- 0 VA 6333... -- -- -- 34 31 Space -- -- 0 VA 6333... 3 50 A Compressor 50 HP 32
29 -- -- -- 0 VA 2777... -- -- -- 30
27 -- -- -- 0 VA 2777... -- -- -- 28
25 Spare - Old Strip Tank 40 A 3 0 VA 2777... 3 40 A ACCU-1 26 23 -- -- -- 2777... 1136... -- -- -- 24 21 -- -- -- 2777... 1136... -- -- -- 22
19 ACCU-1 40 A 3 2777... 1136... 3 20 A AHU2 20
17 -- -- -- 3040... 2400... -- -- -- 18 15 -- -- -- 3040... 2400... -- -- -- 16 13 Downdraft Table 15 HP Composite Repair 4 40 A 3 3040... 2400... 3 25 A Downdraft Table 10 HP Composite Repair 4 14 11 -- -- -- 1600... 4000... -- -- -- 12 9 -- -- -- 1600... 4000... -- -- -- 10 7 MAU4 - Condenser3 Power 20 A 3 1600... 4000... 3 20 A MAU4 - Condenser1 Power 8 5 -- -- -- 7753... 19958... -- -- -- 6 3 -- -- -- 12253... 19958... -- -- -- 4
1 T3PP-1 70 A 3 12253... 19958... 3 100 A DP 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating: 800 A Mounting: Surface Wires: 4 Mains Rating: 800 A
Supply From: 500 kVA, 0 V/12470 V, Three... Phases: 3 Mains Type:
Location: Mechanical Room 14 Volts: 480/277 Wye A.I.C. Rating:
Branch Panel: MDP
EF-2 motor starter (2,4,6) is in off poisition and wiring disconnected. Old dust collector circut 8,10, 12 is on on positio, however old dust collector is no longer present. Curcuit 1,3,5 probably new connection for new paint booth EF-2 adn MAU-1 fan. Circuit 7,9,11 old motor start was removed - trace to identify.
Notes:
Legend:
Total Amps: 93 A 93 A 56 A Total Load: 12253 VA 12253 VA 7753 VA
29 Space -- -- 0 VA 0 VA -- -- Space 30 27 Space -- -- 0 VA 0 VA -- -- Space 28 25 Space -- -- 0 VA 0 VA -- -- Space 26 23 Space -- -- 0 VA 0 VA -- -- Space 24 21 Space -- -- 0 VA 0 VA -- -- Space 22 19 Space -- -- 0 VA 0 VA -- -- Space 20 17 -- -- -- 665 VA 0 VA -- -- Space 18
15 -- -- -- 665 VA 0 VA -- -- -- 16
13 Dust Collector Chemical Storage 1 20 A 3 665 VA 0 VA 2 20 A Power To Disconnect For Washrack 14
11 -- -- -- 987 VA 0 VA -- -- -- 12
9 -- -- -- 987 VA 4500... -- -- -- 10
7 MS PB PUMP 5HP, 0 V/240 V, Three Phase, 3... 30 A 3 987 VA 4500... 3 45 A Dust Collector Strip Shop 2 8 5 -- -- -- 3051... 3051... -- -- -- 6 3 -- -- -- 3051... 3051... -- -- -- 4 1 Motor Paint Booth Room 17 60 A 3 3051... 3051... 3 45 A MS EF-2 240V, 0 V/240 V, Three Phase, 3 Wires,... 2
CKT Load Name Trip Poles A B C Poles Trip Load Name CKT
Notes:
Enclosure: Type 1 MCB Rating: 150 A Mounting: Surface Wires: 3 Mains Rating: 100 A
Supply From: T3PP-1 Phases: 3 Mains Type:
Location: Mechanical Room 14 Volts: 120/240 Delta A.I.C. Rating:
Branch Panel: PP-1
Circuit 5 and 7 not working needs repair.
Notes:
Legend:
Total Amps: 71 A 85 A 27 A Total Load: 7829 VA 9509 VA 3247 VA
17 -- -- -- 1167... 0 VA -- -- Space 18 15 -- -- -- 1167... 0 VA -- -- Space 16 13 Ventilator / Air Cleaners, 120 V/208 V, Three Phas... 20 A 3 1167... 0 VA -- -- -- 14 11 Space -- -- 0 VA 2080... -- -- -- 12 9 Space -- -- 0 VA 2080... 3 20 A Heat Table - Power Composite Repair 4 10
7 -- -- -- 200 VA 200 VA -- -- -- 8
5 Cord Reel - Power Composite Repair 4 20 A 2 0 VA 0 VA 2 30 A Cord Reel - Power Composite Repair 4 6
3 -- -- -- 5400... 863 VA -- -- -- 4
1 Oven - Power Composite Repair 4 50 A 2 5400... 863 VA 2 30 A Dryer 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 100 A
Supply From: TS Phases: 3 Mains Type:
Location: Composite Repair 4 Volts: 208Y/120 A.I.C. Rating:
Branch Panel: PP-2 old dust collector filtering system Circuit 8, 10, 12 should have been disconnected. Old filter system. circuit 19,21,22 reuse for MAU-4 Blower.
Notes:
Legend:
Total Amps: 72 A 72 A 72 A o Total Load: 19958 VA 19958 VA 19958 VA 29 Space -- -- 0 VA 0 VA -- -- Space 30 27 Space -- -- 0 VA 0 VA -- -- Space 28 25 Space -- -- 0 VA 0 VA -- -- Space 26
23 -- -- -- 480 VA 416 VA -- -- -- 24
21 -- -- -- 480 VA 416 VA -- -- -- 22
19 ST MAU-4, 277 V/480 V, Three Phase, 4 Wires,... 20 A 3 480 VA 416 VA 3 15 A MS EF-3 & 4, 277 V/480 V, Three Phase, 4 Wires,... 20
17 -- -- -- 0 VA 942 VA -- -- -- 18
15 -- -- -- 0 VA 942 VA -- -- -- 16
13 MS MAU-2, 277 V/480 V, Three Phase, 4 Wires,... 20 A 3 0 VA 942 VA 3 20 A Air Dryer Mechanical Room 14 14
11 -- -- -- 384 VA 665 VA -- -- -- 12
9 -- -- -- 384 VA 665 VA -- -- -- 10
7 ST EF-1, 277 V/480 V, Three Phase, 4 Wires, Wye 20 A 3 384 VA 665 VA 3 20 A Filter System Strip Shop 2 8 5 -- -- -- 16000... 1072... -- -- -- 6 3 -- -- -- 16000... 1072... -- -- -- 4 1 MS MAU-3 15 A 3 16000... 1072... 3 20 A MS AHU1 & AHU2, 277 V/480 V, Three Phase, 4... 2
CKT Load Name Trip Poles A B C Poles Trip Load Name CKT
Notes:
Enclosure: Type 1 MCB Rating:
Mounting: Surface Wires: 4 Mains Rating: 100 A
Supply From: MDP Phases: 3 Mains Type:
Location: Mechanical Room 14 Volts: 480/277 Wye A.I.C. Rating:
Branch Panel: DP
| Sheets |
| E101 - Existing HVAC Electrical Plan |
| E102 - Proposed HVAC Electrical Plan |
| E601 - Electrical Panel Schedule |
| G-001 - Cover Sheet |
| M101 - Existing HVAC Flr, Roof and ISO Plan |
| M102 - HVAC Demolition Plan |
| M103 - Proposed HVAC Plan |
| M601 - HVAC Schedule |
| M602 - DDC ARCH & AHU1 Control Diagrams |
| M603 - AHU2 & MAU Sequence of Operation |
| 2018-02-01T11:33:01-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T11:34:30-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T11:35:03-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T11:35:35-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T11:36:22-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T11:36:55-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T11:37:36-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T11:38:15-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T11:38:58-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T11:40:26-0600 | |
| HOUSEN.EVON.O.1026573064 |
| 2018-02-01T13:41:35-0600 | |
| CONFER.RONALD.A.1031942639 |
| 2018-02-02T12:24:23-0600 | |
| BOSMA.PETER.F.1009580642 |
File details come from the government source that posted it.