This document contains questions and answers regarding amendment 1 to federal contract number 70Z080-22-Q-P4502800 for CGC VALIANT annual availability work in fiscal year 2022. The answers provide details on requirements for tenting the flight deck area, guidelines for contractor personnel taking ultrasonic test shots and submitting reports, and confirmation that shore power and crane services will not be available to contractors. Contractors must follow Standard Specification 6310 and meet all applicable local, state, and environmental regulations as the cutter is homeported in Naval Base Mayport, Florida. The period of performance is from November 15, 2021 to December 13, 2021 and the point of contact is Kaity George who can be reached at kaity.george@uscg.mil.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

70Z080-22-Q-P4502800

Question:

Will tenting of the flight deck area be required?

Answer :

The contractor needs to reference and abide by SFLC STD SPEC 6310. Also, the cutter is homeported out of Naval Base Mayport, FL, so all local, state, and federal environmental requirements need to be met.

Will contractor personnel be permitted to take the UT shots and report?

Answer :

There are 50 ut shots in work item 09, there are 100 ut shots in work item 10, and there are 250 ut shots in work item 08, if they run out of ut shots, then they can submit a CFR for more.

Will shore power be available for contractor use?

Answer:

No

Will crane service be available for setting equipment?

Answer:

No