STRUCTURE SUMMARY STRUCTURE NO. 3700-005S
PYRITE MINE BRIDGE INSPECTION DATE: 3/2/15
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... STEEL NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... TRUSS - THRU NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 2 STRUCT. TOTAL LENGTH: .. 53.0 FT (16.2 M)
DECK TYPE: ......................... WOOD OR TIMBER MAX. SPAN LENGTH: .......... 53.0 FT (16.2 M)
WEARING SURFACE: .......... OTHER DECK WIDTH: ...................... 12.0 FT (3.7 M)
ABUT. FOUNDATIONS: ........ UNKNOWN CURB TO CURB WIDTH: ..... 11.3 FT (3.4 M)
PIER FOUNDATION(S): ........ N/A YEAR BUILT:
ABUTMENT / PIER MAT'L: ... MASONRY YEAR RECONSTRUCTED: .. 1995
PROJ./PLAN REF. NO: ......... 10(1) / NONE SKEW ANGLE: ..................... 0 °
NPS ROAD CLASS: .............. 6 - RESTRICTED FRACTURE CRITICAL: ........ YES
STRUCTURE HISTORY: ...... 1995-FLOOR BEAMS, STRINGERS, AND DECK PLANKS REPLACED; TRUSS MEMBER
REPAIRED; STRUCTURAL STEEL PAINTED.
LOCATION
PRINCE WILLIAM FOREST PARK MILE POINT: ..................... 1.10 (KM PT 1.77)
STATE: ................................. VIRGINIA LOCATION: I-95 to Exit 150 (VA Route 619) W. Immed R into Park. L on Scenic Drive. R at fork after Parking FACILITY CARRIED: ............ PYRITE MINE ROAD
Area C. R on Pyrite Mine Road after Parking Area D.
FEATURE INTERSECTED: .. QUANTICO CREEK 1.1 miles to bridge. KEY REQUIRED.
STRUCTURE EVALUATION SUMMARY
This steel "pony" truss bridge is currently closed to vehicle traffic due to severe damage to the north truss sustained in 2006 when a tree fell onto the structure. The damage consists of a bent and cracked outer steel channel and support plate for the upper chord, with lateral and torsional distortion also evident. The bridge is currently posted for "No Motor Vehicles" at the west approach.
The recommendation for closure of the bridge to vehicle traffic was made in a letter from FHW A to the Park Superintendent dated March 21, 2007, and the recommendation remains in effect. After repairs to the damaged top chord are completed, FHW A will reinspect the bridge and reassess the load capacity of the structure.
Other problems with the bridge include two loose and bent diagonal truss bracing members; soil and debris accumulation on the deck surface, between the deck planks, and on the bearing areas; and an undermined tree on the east channel bank upstream of the bridge that could also strike and damage the bridge if it were to fall.
The bracing should be tightened as necessary, the timber curbs raised off of deck and the debris should be removed to prevent premature deterioration of the deck planks and structural steel members due to trapped moisture, and the undermined and fallen trees should be removed.
INSPECTION TEAM: G. GOODLIN, R. SILVESTRY
CONDITION ASSESSMENT:
GARY J. GOODLIN, FIELD TEAM LEADER 703-404-6253
REPORT REVIEW :
MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 7/23/15
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
STRUCTURE SUMMARY STRUCTURE NO. 3700-005S
STRUCTURE EVALUATION SUMMARY CONTINUED
It should also be noted that the channel flows against the east abutment, causing minor to moderate scour with undermining. This situation will likely continue to worsen until the channel is redirected away from the abutment. The channel should be redirected in the near future, and the areas of undermining should be repaired with grout.
Engineered riprap should then be placed along the east abutment and upstream wingwall to help prevent additional scour.
These corrective measures should be taken to help prevent the development of more serious or costly problems in the future.
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 3700-005S
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
A226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
59.5 REPAIR DAMAGE TO TOP CHORD OF NORTH TRUSS. SPLICE IN NEW CHANNEL
MEMBERS OR REPLACE COMPETE CHANNEL MEMBERS. REPLACE TOP BATTEN
PLATE OVER DAMAGE AND LOWER BATTEN TIES AS NEEDED.
1 LS
60.9, 61.1 REDIRECT CHANNEL AWAY FROM EAST ABUTMENT TO ARREST SCOUR. REPAIR
UNDERMINING WITH GROUT, AND PLACE ENGINEERED RIPRAP ALONG EAST
ABUTMENT AND UPSTREAM WINGWALL.
50 CY
58.5,7, 60.3 REMOVE SOIL AND DEBRIS FROM DECK AND BEARING AREAS. RAISE TIMBER
CURB TO INCREASE REVEAL.
1 LS
61.2 REMOVE UNDERMINED TREE ON EAST UPSTREAM CHANNEL BANK AND FALLEN
TREES IN UPSTREAM AND DOWNSTREAM CHANNEL.
1 LS
59.5 TIGHTEN DIAGONAL MEMBER (U3-L2) AT MIDSPAN OF BOTH TRUSSES. 2 EA
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
PRELIM. REHABILITATION TOTAL:
PRELIM. RECONSTRUCTION TOTAL: ..
TOTAL ITEMIZED COSTS:
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates assume that the recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 3700-005S
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
N
58. DECK
ITEM REFERENCE AND REMARKS
OTHER
ALIGNMENT
DEFLECTION AND/OR VIBRATION
FASCIA(E)
DIAPHRAGMS AND BRACING
TRUSSES
FLOOR BEAMS AND STRINGERS
ARCH(ES) OR SLAB(S)
GIRDERS OR BEAMS
BEARING DEVICES
59. SUPERSTRUCTURE
OTHER
DEFLECTION AND/OR VIBRATION
UTILITIES
DRAINS AND DRAINAGE
PARAPETS AND/OR RAILINGS
CURBS, SIDEWALKS, AND MEDIAN
RIDEABILITY
WEARING SURFACE
EXPANSION JOINTS
DECK SLAB
ABUTMENTS
60. SUBSTRUCTURE
1.
10.
2.
3.
4.
5.
6.
7.
8.
9.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PAINT
11.
G N N G P N G N G
N G
N F G N F N
N
N
G
G
58.1,4 4"X12" (ACTUAL) DECK PLANKS ARE UNEVEN, PRODUCING
SLIGHTLY ROUGH RIDE.
58.5 MINOR CHECKING OF TIMBER CURBS THROUGHOUT. NORTH CURB
IS SLIGHTLY MISALIGNED WITH 1/4" OFFSET NEAR MIDSPAN. SEE
ALSO 58.7.
58.7 MINOR TO MODERATE DEBRIS AND SOIL ACCUMULATION ON DECK
AND BETWEEN DECK PLANKS HINDERS DRAINAGE; SOIL
ACCUMULATION IS PARTICULARLY HEAVY AT EAST END, WITH
MODERATE RUTTING.
TIMBER CURBS TRAP SOIL AND DEBRIS ON DECK.
59.5 TOP CHORD STEEL CHANNEL OF NORTH TRUSS, NEAR U2 (3'-6"
FROM U2-L2 VERTICAL TRUSS MEMBER) IS CRACKED ALONG WITH
SUPPORT PLATE. NOTICEABLE LATERAL AND TORSIONAL
DISTORTION AND TORSION OF THIS PRIMARY STRUCTURE
ELEMENT. CRACK IS 1/16" WIDE AT TOP OF WEB AND INCREASES
TO 3/16" AT BOTTOM OF WEB WITH BOTTOM FLANGE AND
ADJOINING BATTEN PLATE CRACKED THROUGH RIVET HOLE FOR A
WIDTH OF 5/16". MAJORITY OF BATTEN PLATE HAS CRACKS AT A
RIVET HOLE.
UPPER SUPPORT PLATE ADJACENT TO THIS DAMAGE AND U2-L2
VERTICAL MEMBER IS DISTRESSED WITH DEFORMATION OF
BOTTOM FLANGE AND A CRACK AT RIVET CONNECTION MEASURED
AT 1/8" WIDE. DAMAGE WAS CAUSED BY A FALLEN TREE THAT HIT
STRUCTURE IN 2006, AS PER PARK PERSONNEL.
59.5,7 STRUCTURAL STEEL WAS PAINTED IN 1995 AND REPAIRS WERE
MADE TO STEEL TRUSSES AND TO LATERAL BRACING. MINOR TO
MODERATE PITTING OF STEEL TRUSS MEMBERS IS VISIBLE IN
SOME LOCATIONS.
MINOR PACK RUSTING BETWEEN PLATE OF TOP CHORD. LOOSE
AND BENT DIAGONAL COUNTER (U3-L2) FOR BOTH TRUSSES.
BREASTWALLS OR COLUMNS1. F
PILE BENTS2. N
CAPS AND/OR BEARING SEATS3. F
BACKWALLS AND/OR BULKHEADS4. N
FOUNDATIONS5. N
WINGWALLS6. G
WEEP HOLES7. N
EXPANSION JOINTS8. N
EROSION AND/OR SCOUR9. F
SETTLEMENT OR DEFLECTION10. G
SLOPE PROTECTION11. N
OTHER 12. N
PIER(S)
N13. WALLS AND/OR COLUMNS
N14. PILE BENTS
N15. CAPS AND/OR BEARING SEATS
N16. FOUNDATIONS
N17. EROSION AND/OR SCOUR
N18. SETTLEMENT OR DEFLECTION
N19. OTHER
INSPECTION DATE: 3/2/15
STRUCTURE NO. 3700-005S FIELD INSPECTION REPORT
PYRITE MINE BRIDGE
ITEM REFERENCE AND REMARKS
AVERAGE CLEAR OPENING 8.
7. NORMAL VELOCITY
ADEQUACY OF OPENING 6.
5. OTHER
4. WATERWAY OBSTRUCTIONS
CHANNEL PROTECTION3.
EROSION AND/OR SCOUR2.
ALIGNMENT1.
61. CHANNEL 6
F F G G N
MED
SUFF
6 FT.
9. STREAM BED COMPOSITION :
SILT, ROCK, GRAVEL
222. APPROACHES 8
OTHER 9.
ALIGNMENT 8.
SIGNS7.
SETTLEMENT 6.
EROSION5.
SURFACING4.
APPROACH GUARDRAIL 3.
2. RELIEF JOINTS
APPROACH SLABS1. N
N N G G G N G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION5.
EROSION AND/OR SCOUR4.
FOUNDATION3.
WEEP HOLES2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDSD.
APPROACH GUARDRAILSC.
TRANSITIONSB.
BRIDGE RAILINGSA. N
N N N
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required.
60.1 MORTAR CRACKED OR MISSING FROM SOME MASONRY JOINTS.
APPROXIMATELY 1/16" WIDE VERTICAL CRACK IN WEST ABUTMENT
BREASTWALL. SEVERAL CRACKED STONES AT EAST ABUTMENT.
WATER LEVEL GAUGE AND STORAGE BOX AT UPSTREAM SIDE OF
EAST ABUTMENT.
60.3 MODERATE ACCUMULATION OF DEBRIS ON BEARING SEATS. VOID
IN WEST ABUTMENT BEARING SEAT CAP.
60.9 MINOR TO MODERATE SCOUR AT EAST ABUTMENT, UPSTREAM
SIDE; MODERATE AT ADJACENT WINGWALL (10' LONG X 2' WIDE X
1-1/2' DEEP). 9" VOID UNDER ABUTMENT IN ONE LOCATION. SEE
ALSO 61.1.
61.1 CHANNEL HAS SHIFTED AGAINST EAST ABUTMENT. 90 DEGREE
BEND IN CHANNEL UPSTREAM OF STRUCTURE.
61.2 MINOR CHANNEL BANK EROSION; MODERATE ALONG EAST BANK,
UPSTREAM SIDE, WITH A LARGE TREE UNDERMINED. TREE COULD
FALL AND STRIKE STRUCTURE IN SAME MANNER AS OCCURRED IN
2006 (ALSO SEE 59.5 AND 61.4).
61.3 RIPRAP PRESENT AT DOWNSTREAM SIDE OF EAST ABUTMENT.
61.4 LARGE TREE IN UPSTREAM CHANNEL HAS BEEN REMOVED. LARGE
TREE TRUNK LAYING ALONG EAST BANK DOWNSTREAM OF BRIDGE
HAS BEEN REMOVED.
222.7,9 BRIDGE IS CURRENTLY POSTED FOR "NO MOTOR VEHICLES" AT
WEST APPROACH. FIBERGLASS OBJECT POLES IN TRAVEL LANE
HAVE BEEN REMOVED.
STRUCTURE LOAD RATING STRUCTURE NO. 3700-005S
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 8 7 13 12
HS 10 9 16 15
TYPE 3 9 8 15 13
TYPE 3S2 13 12 23 21
TYPE 3-3 17 15 28 25
DESIGN LOADING: UNKNOWN
CAPACITY MEETS OR EXCEEDS DESIGN LOAD
X CAPACITY IS LESS THAN DESIGN LOAD
X ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION: 12/79
LOAD RATING CONTROLLED BY: MOMENT CAPACITY OF STRINGERS
REMARKS: BRIDGE IS CURRENTLY CLOSED TO VEHICLE TRAFFIC. RATING IS VALID ONLY IF DAMAGED TOP CHORD
IS REPAIRED AS OUTLINED ON PAGE 3.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3700-005S
STRUCTURE IDENTIFICATION
(201) PARK: PRINCE WILLIAM FOREST PARK
(202) STRUCTURE NAME: .......... PYRITE MINE BRIDGE
(203) STRUCTURE KIND: ............ 1 - BRIDGE
(204) STRUCTURE NUMBER: ..... 3700-005S
(205) NPS REGION: .................... 2 - NATIONAL CAPITAL
(206) ROUTE CODE NUMBER: ... 406
(207) ROAD SECTION NO: .......... 005S
(208) NPS ROAD CLASS: ............ 6 - RESTRICTED
(209) WITHIN NPS BNDRY?: ....... YES
(210) OPERATING UNIT: ............. PARK
(211) PROJECT NO(S): ................ 10(1)
(212) DRAWING NUMBERS: ....... NONE
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE
(1) STATE:
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY/PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR: ..
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORICAL DESIGNATION: ..
513 - VIRGINIA (VA)
153 - PRINCE WILLIAM
161004060
QUANTICO CREEK
PYRITE MINE ROAD
3700005S0000000
I-95 to Exit 150 (VA Rout
99.99 FT (99.99 M)
1.10 (KM PT 1.77)
3 - FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
3 - STEEL
10 - TRUSS - THRU
53.0 FT (16.2 M)
53.0 FT (16.2 M)
0 - UNKNOWN
0 - UNKNOWN
6 - N/A
6 - N/A
8 - WOOD OR TIMBER
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 9 - OTHER
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 0 - UNKNOWN (41) LOAD RESTRICTION: ......... K - BRIDGE CLOSED
(66) INVENTORY RATING: ...... 9.6 TONS (8.7 METRIC TONS) (70) BRIDGE POSTING: .............. 0 - POSTING REQUIRED
(64) OPERATING RATING: ...... 16.0 TONS (14.5 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 3/15 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... YES
INSP. EVERY: 24 MONTHS - LAST INSP. : 3/15 (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3700-005S
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 38°34'37.10" (51) CURB TO CURB WIDTH: ........... 11.3 FT (3.4 M)
(17) LONGITUDE: ......................... 77°20 80.50" (52) DECK WIDTH: ............................ 12.0 FT (3.7 M)
(19) DETOUR LENGTH: ............... 10 MI (16 KM) (32) APPR. ROADWAY WIDTH: ........ 12.0 FT (3.7 M)
(28A) LANES ON STRUCT: .......... 01 (213) APPR. PAVEMENT WIDTH: ..... 12.0 FT (3.7 M)
(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 0.0 FT (0.0 M)
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 0.0 FT (0.0 M)
(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 10 (34) SKEW ANGLE: ............................ 0 °
(30) YEAR OF ADT: ...................... 2007 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 11 (47) TOTAL HORIZ. CLEARANCE: .... 11.3 FT (3.4 M)
(115) YEAR OF FUTURE ADT: ..... 2027 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)
(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 0 - N/A
(111) ABUT. OR PIER PROT: ....... 1 - NAV PROTECTION NOT REQUIRED MATERIAL: .............................. 0 - N/A
DESIGN TYPE: ........................ 0 - N/A
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 3.00 FT (0.91 M)
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... NNNN
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
U - Unknown foundation. Not ye
1 - MAINTENANCE
A - CRITICAL
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
1995-FLOOR BEAMS, STRINGERS, AND DECK PLANKS REPLACED; TRUSS MEMBER REPAIRED; STRUCTURAL STEEL PAINTED.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
APPENDIX STRUCTURE NO. 3700-005S
PHOTOGRAPHS STRUCTURE NO. 3700-005S
FLOW
PHOTO #1 - LOOKING EAST; NOTE FIBERGLASS OBJECT POLES IN
TRAVEL LANE HAVE BEEN REMOVED
PHOTO #2 - NORTH (UPSTREAM) SIDE
PHOTO #3 - GENERAL TOPSIDE VIEW OF STRUCTURE LOOKING EAST
PHOTO #4 - NORTH CURB IS SLIGHTLY MISALIGNED WITH 1/4" OFFSET
NEAR MIDSPAN
PHOTO #5 - CRACK IN TOP CHORD OF NORTH TRUSS, DUE TO TREE
IMPACT
PHOTO #6 - CLOSE UP OF CRACK IN TOP CHORD OF NORTH TRUSS
PHOTO #7 - VIEW OF TREE IMPACT DAMAGE TO NORTH TRUSS TOP
CHORD
PHOTO #8 - LOOSE AND BENT DIAGONAL COUNTER (U3-L2) FOR BOTH
TRUSSES; NORTH TRUSS SHOWN
PHOTO #9 - RUST BLOOMING AT PANEL POINT U2 OF SOUTH TRUSS,
CAUSING COVER PLATE TO BULGE BETWEEN RIVETS
PHOTO #10 - GAP IN FLOOR BEAM TO TRUSS CONNECTION DUE TO
LATERAL AND TORSIONAL DISTORTION
PHOTO #11 - BRIDGE IS CURRENTLY POSTED FOR "NO MOTOR
VEHICLES" AT WEST APPROACH
PHOTO #12 - GENERAL UNDERSIDE VIEW LOOKING WEST
PHOTO #13 - GENERAL VIEW OF EAST ABUTMENT
PHOTO #14 - WATER LEVEL GAUGE AT UPSTREAM SIDE OF EAST
ABUTMENT
PHOTO #15 - VOID IN WEST ABUTMENT
BEARING SEAT CAP
PHOTO #16 - APPROXIMATELY 1/16" WIDE
VERTICAL CRACK IN WEST ABUTMENT
BREASTWALL
PHOTO #17 - DEBRIS ACCUMULATION ON BEARING SEAT AT SOUTH
END OF WEST ABUTMENT
PHOTO #18 - EROSION OF EAST UPSTREAM CHANNEL BANK
PHOTO #19 - VIEW FROM BRIDGE LOOKING UPSTREAM
PHOTO #20 - VIEW FROM BRIDGE LOOKING DOWNSTREAM
File details come from the government source that posted it.