STRUCTURE SUMMARY STRUCTURE NO. 5460-093P
COLLINS CREEK CULVERT INSPECTION DATE: 5/25/17
CULVERT IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ........ CONCRETE NO. OF BARRELS:
FOUNDATION: ....................... SPREAD FTG ON BEARING MAT'L BARREL LENGTH: ............... 53 FT (16 M)
STRUCT. TOTAL LENGTH: ... 22.5 FT (6.9 M) SKEW ANGLE: ..................... 0 °
MAX. SPAN LENGTH: ............ 7.2 FT (2.2 M) YEAR BUILT:
PROJ./PLAN REF. NO: .......... 000000000000 / NONE YEAR RECONSTRUCTED: .. N/A
NPS ROAD CLASS: ............... 1 - PRINCIPAL PARK ROAD
STRUCTURE HISTORY: ....... 2011 - STRUCTURE WIDENED, NEW EAST HEADWALL AND WINGWALLS, ROADWAY
REPAVED AND RESTRIPED.
LOCATION
GREAT SMOKY MOUNTAINS NATIONAL PARK MILE POINT: ..................... 29.58 (KM PT 47.60)
STATE: .................................. NORTH CAROLINA LOCATION: 10.7 MILES SOUTH OF NEWFOUND GAP; IMMEDIATELY SOUTH OF ENTRANCE ROAD FACILITY CARRIED: ............. NEWFOUND GAP ROAD
TO COLLINS CREEK PICNIC AREA.
FEATURE INTERSECTED: ... COLLINS CREEK
STRUCTURE EVALUATION SUMMARY
This triple barrel concrete culvert is in fair structural condition. The structure has been widened twice in its history.
Site-related problems include an accumulation of rocks and gravel in the north and center barrels; the accumulation effectively redirects the channel flow through the south barrel.
There is also moderate erosion behind the southwest wingwall, and along the south downstream channel bank with a fallen tree across the channel. The concrete apron is exposed up to 8" at the downstream end, and up to 3" at the upstream end; no undermining was noted, however.
Additional problems include widespread moderate scaling with exposed rebar on the floor of the two older portions of the barrels; spalling with exposed rebar on the top slab underside in the south barrel; and exposed form ties in the center barrel. In addition, culvert markers are not provided.
Corrective measures should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.
INSPECTION TEAM: R. SILVESTRY, L. ELLIS
CONDITION ASSESSMENT:
REINALDO SILVESTRY, FIELD TEAM LEADER 703-404-6251
REPORT REVIEW:
MARCUS MILLER, P.E., BRIDGE INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 10/4/17
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5460-093P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure exhibits severe deterioration, presents a safety hazard, or is designated a high priority due to age and/or condition.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
D226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
61.4, 62.5 REMOVE ROCK AND GRAVEL ACCUMULATION FROM NORTH AND CENTER
BARRELS.
1 LS
62.1 CLEAN AND SEAL EXPOSED REBAR ON TOP SLAB OF SOUTH BARREL, EXPOSED
FORM TIES IN CENTER BARREL AND EXPOSED REBAR ON FLOOR OF TWO OLDER
PORTIONS WITH APPROVED PROTECTIVE COATING.
7 SF
222.7 INSTALL REFLECTIVE OBJECT MARKERS. 4 EA
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
62.6 PLACE SCOUR COUNTERMEASURES ALONG SOUTHWEST
WINGWALL, DOWNSTREAM APRON, AND ALONG SOUTH
DOWNSTREAM CHANNEL BANK TO PREVENT FURTHER SCOUR
1 LS
CONTRACT COSTS FOR MOBILIZATION, TRAFFIC CONTROL, AND
DESIGN CONSTRUCTION ENGINEERING (APPROXIMATELY 70%
TOTAL REHAB COST) PLUS PARK LOCATION FACTOR.
1 LS
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 5460-093P
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or sec ion loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
STREAM BED COMPOSITION :9.
AVG. CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION 3.
EROSION AND/OR SCOUR 2.
ALIGNMENT 1.
61. CHANNEL 6
F F N F
4 FT.
HIGH
SUFF
N
ITEM REFERENCE AND REMARKS
62. CULVERT 6
PARAPETS AND/OR RAILINGS 9.
ADEQUACY OF COVER 8.
SETTLEMENT AND/OR DEFLECTION 7.
EROSION AND/OR SCOUR 6.
DEBRIS AND/OR SILT 5.
WINGWALLS 4.
HEADWALLS 3.
FOOTINGS 2.
BARREL(S)1.
ROADWAY SURFACE 10.
RIDEABILITY 11.
OTHER 12. (STRIPING)
F N G G F F G G N G G G
222. APPROACHES 7
OTHER 9.
ALIGNMENT 8.
SIGNS 7.
SETTLEMENT 6.
EROSION 5.
SURFACING 4.
APPROACH GUARDRAIL 3.
RELIEF JOINTS 2.
1. APPROACH SLABS
(STRIPING)
N N N G G G N G G
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION 5.
EROSION AND/OR SCOUR 4.
FOUNDATION 3.
WEEP HOLES 2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAILS C.
TRANSITIONS B.
BRIDGE RAILINGSA.
APPROACH GUARDRAIL ENDS D.
N N N N
GRAVEL, SAND, ROCK
61.1,2,4, STREAM FLOWS THROUGH SOUTH BARREL ONLY. HEAVY ROCK
62.5,6 AND GRAVEL ACCUMULATION IN NORTH AND CENTER BARRELS
FORCES FLOW THROUGH SOUTH BARREL. MODERATE EROSION
BEHIND SOUTHWEST WINGWALL. MODERATE EROSION ALONG
SOUTH DOWNSTREAM CHANNEL BANK HAS EXPOSED ROOTS OF
SEVERAL LARGE TREE STUMPS.
8" OF CONCRETE APRON EXPOSED AT DOWNSTREAM END OF
STRUCTURE; 3" EXPOSED AT UPSTREAM END. NO UNDERMINING
NOTED.
62.1 ORIGINAL STRUCTURE WAS ONCE WIDENED AND HAS BEEN
WIDENED AN ADDITIONAL 11' AT EAST END. OLDEST PORTION OF
STRUCTURE WALLS REMAIN IN GOOD CONDITION WITH ONLY
MINOR SCALING AT BOTTOM OF WALLS. BOTTOM OF BARREL
WALLS HAVE AREAS OF PREVIOUS PATCHING.
MINOR CRACKING WITH EFFLORESCENCE AND WATER LEAKAGE AT
CONSTRUCTION JOINTS. MINOR SPALL WITH EXPOSED REBAR ON
UNDERSIDE OF TOP SLAB, NEAR EAST END OF SOUTH BARREL.
FORM TIES REMAIN IN CENTER BARREL WALLS.
WIDESPREAD MODERATE SCALING OF CONCRETE FLOOR WITH
EXPOSED REBAR IN TWO OLDER PORTIONS OF STRUCTURE;
NEWEST PORTION HAS GROUTED STONE FLOOR.
62.3,4 MINOR VEGETATION GROWTH ON WEST HEADWALL. MODERATE
VEGETATION GROWTH ON WEST WINGWALLS.
222.7 NO REFLECTIVE OBJECT MARKERS PROVIDED.
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required. 3 OF 13
STRUCTURE LOAD RATING STRUCTURE NO. 5460-093P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 15 14 25 23
HS 27 24 45 41
TYPE 3 31 28 52 47
TYPE 3S2 49 44 82 74
TYPE 3-3 60 54 100 91
DESIGN LOADING: UNKNOWN
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: RATING IS BASED ON ENGINEERING JUDGEMENT IN ACCORDANCE WITH AASHTO MANUAL FOR BRIDGE
EVALUATION (MBE).
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5460-093P
STRUCTURE IDENTIFICATION
(201) PARK: GREAT SMOKY MOUNTAINS NATIONAL PARK (1) STATE: ....................................... 374 - NORTH CAROLINA (NC)
(202) STRUCTURE NAME: .......... COLLINS CREEK CULVERT (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............ 2 - CULVERT (3) COUNTY CODE: ........................ 173 - SWAIN
(204) STRUCTURE NUMBER: ..... 5460-093P (4) CITY/PLACE CODE:
(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... 10 (6) FEATURES INTERSECTED:....... COLLINS CREEK
(207) ROAD SECTION NO: .......... 093P (7) FACILITY CARRIED: .................. NEWFOUND GAP ROAD
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5460093P0000000
(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 10.7 MILES SOUTH OF NEWF
(210) OPERATING UNIT: ............. S. DIST. (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................ 000000000000 (11) MILE POINT: ............................. 29.58 (KM PT 47.60)
(212) DRAWING NUMBERS: ....... NONE (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
1 - CONCRETE
19 - CULVERT
7.2 FT (2.2 M)
22.5 FT (6.9 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
N - NOT APPLICABLE
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. N - NOT APPLICABLE
B) TYPE MEMBRANE: ................. N - NOT APPLICABLE
C) TYPE PROTECTION: .............. N - NOT APPLICABLE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 0 - UNKNOWN (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 27.0 TONS (24.5 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 45.1 TONS (40.9 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 5/17 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
APPENDIX STRUCTURE NO. 5460-093P
PHOTOGRAPHS STRUCTURE NO. 5460-093P
PHOTO #1 - LOOKING NORTH TOWARD NEWFOUND GAP
FLOW
PHOTO #2 - WEST (UPSTREAM) SIDE
PHOTO #3 - GENERAL TOPSIDE VIEW LOOKING SOUTH
PHOTO #4 - GENERAL VIEW OF CLEAR ZONE ON EAST SIDE; NOTE
LACK OF OBJECT MARKER
PHOTO #5 - GENERAL UNDERSIDE VIEW OF CENTER BARREL LOOKING
UPSTREAM; NOTE COBBLES ACCUMULATED ON BARREL FLOOR
PHOTO #6 - CRACKING AND EFFLORESCENCE ALONG CULVERT INSIDE
PERIMETER CONSTRUCTION JOINT; NORTH WALL OF NORTH BARRE
NEAR EAST END SHOWN
PHOTO #7 - SPALLING, CRACKING AND EFFLORESCENCE BUILDUP ON
AND ADJACENT TO CONSTRUCTION JOINTS; SOUTH WALL OF NORTH
BARREL SHOWN
PHOTO #8 - TYPICAL VEGETATION GROWN ALONG WINGWALLS;
SOUTHEAST SIDE SHOWN; NOTE DEBRIS IN BARREL CHANNEL
PHOTO #9 - VEGETATION AND SEDIMENT BUILD-UP ON UPSTREAM
(WEST) SIDE OF NORTH AND CENTER BARRELS
PHOTO #10 - EROSION AT END OF SOUTHWEST WINGWALL
PHOTO #11 - LOOKING UPSTREAM FROM ROADWAY OVER CULVERT
PHOTO #12 - LOOKING DOWNSTREAM FROM ROADWAY OVER
CULVERT