This document is a laboratory report from Eurofins Reservoirs Environmental, Inc., addressed to Harness Environmental, concerning asbestos testing for the Edison Elementary School classrooms flooring project. The report details the analysis of four samples collected from the teachers' lounge and classroom 10, which include black mastic, tan tile, and beige adhesive materials. The samples were analyzed using Polarized Light Microscopy (PLM) on June 24, 2025, with the laboratory accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) and the American Industrial Hygiene Association (AIHA).
The analysis revealed varying levels of asbestos content, with one tan tile sample containing 96% chrysotile asbestos and another containing 100% chrysotile asbestos. The black mastic samples showed 4% and trace amounts of asbestos, while the beige adhesive samples contained no detectable asbestos. The laboratory recommends Transmission Electron Microscopy (TEM) analysis for organically bound materials if PLM results are less than 1%. The report emphasizes the confidential nature of the findings and provides detailed information about the sample locations, composition, and asbestos content, which will be crucial for the planned flooring abatement project at Edison Elementary School.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| S2026-1000 Edison Flooring Abatement RFP.pdf | ||
| Edison ES Flooring Plan 3-26-2024 History of floors.pdf | ||
| Addendum #2 - S2026-1000.pdf | ||
| Asbestos letter for Edison.pdf | ||
| Floor plan showing rooms to be abated.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
June 24, 2025
Sincerely, Jeanne Spencer President
Subcontractor Number:
Laboratory Report: RES 668101-1
Project #/P.O. #: Edison elementary
Project Description: Classrooms flooring
John Harness Harness Environmental 61 Navajo Cir Divide CO 808149688
Dear John, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP, LLC), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
RES 668101-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
by Jessica Parker
06/24/202506/24/202506/24/202506/24/2025
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
4955 Yarrow St, Suite 100, Arvada, CO 80002
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non- AAAA SubSubSubSub AsbestosAsbestosAsbestosAsbestos FibrousFibrousFibrousFibrous YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 668101 -668101 -668101 -668101 - FLOORING 9X9 vct-01-01FLOORING 9X9 vct-01-01FLOORING 9X9 vct-01-01FLOORING 9X9 vct-01-01 A Black mastic 4 NDNDNDND 0 100.0 B Tan tile 96 ChrysotileChrysotileChrysotileChrysotile 6666 0 94.0 668101 -668101 -668101 -668101 - FLOORING 9X9 vct-01-02FLOORING 9X9 vct-01-02FLOORING 9X9 vct-01-02FLOORING 9X9 vct-01-02 A Black mastic TR NDNDNDND 0 100.0 B Tan tile 100 ChrysotileChrysotileChrysotileChrysotile 6666 0 94.0 668101 -668101 -668101 -668101 - cbm-01-01cbm-01-01cbm-01-01cbm-01-01 A Beige adhesive 100 NDNDNDND 0 100.0 668101 -668101 -668101 -668101 - cbm-01-02cbm-01-02cbm-01-02cbm-01-02 A Beige adhesive 100 NDNDNDND 0 100.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Jessica Parker Analyst
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 668101-1
Harness Environmental Edison elementary Classrooms flooring June 23, 2025 EPA 600/R-93/116 - Short Report, Bulk Rush June 24, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
SUBMITTED BY INVOICE TO
Client Sample ID Number
RES Job #: 668101
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Company: Harness Environmental Company: Harness Environmental
Address: 61 Navajo Cir Address: 61 Navajo Cir
Divide, CO 80814-9688 Divide, CO 80814-9688
Project Number and/or P.O. #: Edison elementary Project Zip Code: 80907
Project Description/Location: Classrooms flooring
Contact: John Harness -1 PLM Rush *VERBALS* Phone: (719) 331-8640
Fax:
Cell: (719) 331-8640
Final Data Deliverable Email Address:
harnessenvironmental@yahoo.com
PLM / PCM / TEM DTL RUSH PRIORITY STANDARD Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
Mold Analysis RUSH PRIORITY STANDARD
Special Instructions:
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
1 FLOORING 9X9 vct-01-01 X 12000ft² B 06/23/25 00:00
2 FLOORING 9X9 vct-01-02 X 12000ft² B
3 cbm-01-01 X 56ft² B 06/23/25 12:00
4 cbm-01-02 X 56ft² B
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of Cash or Check. Failure to comply with payment terms may result in a 1.5% monthly interest surcharge.
Relinquished By:
John Harness Date/Time: 06/23/2025 17:33:38 Sample Condition: Acceptable
Received By:
Anna Shilo Date/Time: 06/23/2025 17:35:00 Carrier: Hand
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Client Sample ID Sample Location
FLOORING 9X9 vct-01-01 teachers lounge
FLOORING 9X9 vct-01-02 classroom 10 cbm-01-01 Teachers lounge cbm-01-02 Class 10
Harness Environmental Sample Locations
RES #: 668101
Project Number and/or P.O. #: Edison elementary
Project Description/Location: Classrooms flooring