565-20-201 Replace Fire Alarm System - IFC Drawings.pdf

PDF 34 MB Posted

Attached to
Z1QA--565-20-201 Replace Fire Alarm System (VA-23-00008530)
Solicitation number
36C24623B0002
Issued by

About this file

This document outlines a federal contract opportunity to replace the fire alarm system at a Department of Veterans Affairs medical center. The solicitation seeks bids to perform a site-wide replacement of existing fire alarm systems across the campus to provide a code-compliant, unified fire alarm platform in each building. The new system must be capable of minimal live voice paging and fully integrate with existing VA systems. The basis of design is a Siemens Desigo fire alarm system with graphics computer. Bids are due by the date specified in the solicitation number 36C24623B0002 from the Veterans Health Administration Veterans Integrated Service Network 6.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CO

CH

RA

N

AV

E.

FA

CI

LI

TY

D

R.

RAMSEY ST.

NORTH

FA

CI

RAMSEY ST.

CO

CH

RA

N

AV

E.

FUEL

PUMP

STATION

CRM EXF

GENERAL

GI001 COVER SHEET

GI002 SITE PLAN

FIRE ALARM:

BUILDING 1:

B1.FA101 BUILDING 1 BASEMENT FIRE ALARM PLAN - EXISTING

B1.FA102 BUILDING 1 BASEMENT FIRE ALARM PLAN - EXISTING

B1.FA103 BUILDING 1 FIRST FLOOR FIRE ALARM PLAN - EXISTING

B1.FA104 BUILDING 1 FIRST FLOOR FIRE ALARM PLAN - EXISTING

B1.FA105 BUILDING 1 SECOND FLOOR FIRE ALARM PLAN - EXISTING

B1.FA106 BUILDING 1 SECOND FLOOR FIRE ALARM PLAN - EXISTING

B1.FA107 BUILDING 1 THIRD FLOOR FIRE ALARM PLAN - EXISTING

B1.FA108 BUILDING 1 THIRD FLOOR FIRE ALARM PLAN - EXISTING

B1.FA109 BUILDING 1 FOURTH FLOOR FIRE ALARM PLAN - EXISTING

B1.FA110 BUILDING 1 FOURTH FLOOR FIRE ALARM PLAN - EXISTING

B1.FA111 BUILDING 1 FIFTH FLOOR FIRE ALARM PLAN - EXISTING

B1.FA112 BUILDING 1 FIFTH FLOOR FIRE ALARM PLAN - EXISTING

B1.FA113 BUILDING 1 PENTHOUSE FIRE ALARM PLAN - EXISTING

B1.FA114 BUILDING 1 PENTHOUSE FIRE ALARM PLAN - EXISTING

B1.FA115 BUILDING 1 BASEMENT FIRE ALARM PLAN - PROPOSED

B1.FA116 BUILDING 1 BASEMENT FIRE ALARM PLAN - PROPOSED

B1.FA117 BUILDING 1 FIRST FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA118 BUILDING 1 FIRST FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA119 BUILDING 1 SECOND FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA120 BUILDING 1 SECOND FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA121 BUILDING 1 THIRD FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA122 BUILDING 1 THIRD FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA123 BUILDING 1 FOURTH FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA124 BUILDING 1 FOURTH FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA125 BUILDING 1 FIFTH FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA126 BUILDING 1 FIFTH FLOOR FIRE ALARM PLAN - PROPOSED

B1.FA127 BUILDING 1 PENTHOUSE FIRE ALARM PLAN - PROPOSED

B1.FA128 BUILDING 1 PENTHOUSE FIRE ALARM PLAN - PROPOSED

B1.FA129 BUILDING 1 FIRE ALARM NOTES AND DIAGRAMS

B1.FA130 BUILDING 1 FIRE ALARM NOTES AND DIAGRAMS

B1.FA131 BUILDING 1 FIRE ALARM NOTES AND DIAGRAMS

BUILDING 3

B3.FA101 BUILDING 3 BASEMENT FIRE ALARM PLAN - EXISTING

B3.FA102 BUILDING 3 FIRST FLOOR FIRE ALARM PLAN - EXISTING

B3.FA103 BUILDING 3 SECOND FLOOR FIRE ALARM PLAN - EXISTING

B3.FA104 BUILDING 3 THIRD FLOOR FIRE ALARM PLAN - EXISTING

B3.FA105 BUILDING 3 FOURTH FLOOR FIRE ALARM PLAN - EXISTING

B3.FA106 BUILDING 3 BASEMENT FLOOR FIRE ALARM PLAN - PROPOSED

B3.FA107 BUILDING 3 FIRST FLOOR FIRE ALARM PLAN - PROPOSED

B3.FA108 BUILDING 3 SECOND FLOOR FIRE ALARM PLAN - PROPOSED

B3.FA109 BUILDING 3 THIRD FLOOR FIRE ALARM PLAN - PROPOSED

B3.FA110 BUILDING 3 FOURTH FLOOR FIRE ALARM PLAN - PROPOSED

B3.FA111 BUILDING 3 FIRE ALARM NOTES AND DIAGRAMS

BUILDING 4

B4.FA101 BUILDING 4 FIRE ALARM PLAN - EXISTING

B4.FA102 BUILDING 4 FIRE ALARM PLAN - PROPOSED

B4.FA103 BUILDING 4 FIRE ALARM NOTES AND DIAGRAMS

BUILDING 9

B9.FA101 BUILDING 9 FIRST FLOOR FIRE ALARM PLAN - EXISTING

B9.FA102 BUILDING 9 FIRST FLOOR FIRE ALARM PLAN - PROPOSED

B9.FA103 BUILDING 9 FIRE ALARM NOTES AND DIAGRAMS

BUILDING 10

B10.FA101 BUILDING 10 FIRE ALARM PLAN - EXISTING

B10.FA102 BUILDING 10 FIRE ALARM PLAN - PROPOSED

B10.FA103 BUILDING 10 FIRE ALARM NOTES AND DIAGRAMS

BUILDING 11

B11.FA101 BUILDING 11 FIRE ALARM PLAN - EXISTING

B11.FA102 BUILDING 11 FIRE ALARM PLAN - PROPOSED

BUILDING 21

B21.FA101 BUILDING 21 FIRST FLOOR FIRE ALARM PLAN - EXISTING

B21.FA102 BUILDING 21 FIRST FLOOR FIRE ALARM PLAN - PROPOSED

B21.FA103 BUILDING 21 NOTES AND DIAGRAMS

BUILDING 34

B34.FA101 BUILDING 34 FIRE ALARM PLAN - EXISTING

B34.FA102 BUILDING 34 FIRE ALARM PLAN - PROPOSED

BUILDING 35

B35.FA101 BUILDING 35 FIRE ALARM PLAN - EXISTING

B35.FA102 BUILDING 35 FIRE ALARM PLAN - PROPOSED

BUILDING 45

B45.FA101 BUILDING 45 FIRE ALARM PLAN - EXISTING

B45.FA102 BUILDING 45 FIRE ALARM PLAN - PROPOSED

B45.FA103 BUILDING 45 NOTES AND DIAGRAMS

BUILDING 46

B46.FA101 BUILDING 46 FIRE ALARM PLAN - EXISTING

B46.FA102 BUILDING 46 FIRE ALARM PLAN - PROPOSED

B46.FA103 BUILDING 46 NOTES AND DIAGRAMS

BUILDING 47

B47.FA101 BUILDING 47 FIRE ALARM PLAN - EXISTING

B47.FA102 BUILDING 47 FIRE ALARM PLAN - PROPOSED

B47.FA103 BUILDING 47 NOTES AND DIAGRAMS

BUILDING 48

B48.FA101 BUILDING 48 FIRE ALARM PLAN - EXISTING

B48.FA102 BUILDING 48 FIRE ALARM PLAN - PROPOSED

B48.FA103 BUILDING 48 NOTES AND DIAGRAMS

BUILDING 50

B50.FA101 BUILDING 50 FIRE ALARM PLAN - EXISTING

B50.FA102 BUILDING 50 FIRE ALARM PLAN - PROPOSED

B50.FA103 BUILDING 50 NOTES AND DIAGRAMS

BUILDING 57

B57.FA101 BUILDING 57 FIRE ALARM PLAN - EXISTING

B57.FA102 BUILDING 57 FIRE ALARM PLAN - PROPOSED

B57.FA103 BUILDING 57 NOTES AND DIAGRAMS

BUILDING 70

B70.FA101 BUILDING 70 FIRE ALARM PLAN - EXISTING

B70.FA102 BUILDING 70 FIRE ALARM PLAN - PROPOSED

B70.FA103 BUILDING 70 NOTES AND DIAGRAMS

BUILDING 71

B71.FA101 BUILDING 71 FIRE ALARM PLAN - EXISTING

B71.FA102 BUILDING 71 FIRE ALARM PLAN - PROPOSED

B71.FA103 BUILDING 71 NOTES AND DIAGRAMS

BUILDING 73

B73.FA101 BUILDING 73 FIRE ALARM PLAN - EXISTING

B73.FA102 BUILDING 73 FIRE ALARM PLAN - PROPOSED

B73.FA103 BUILDING 73 NOTES AND DIAGRAMS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

WEST POINT

ENGINEERING ARCHITECTURE

FAYETTEVILLE VAMC

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

PROJECT #565-20-201

REPLACE FIRE ALARM SYSTEM

U.S. Department of Veterans Affairs

WEST POINT ENGINEERS, LLC

ENGINEERING ARCHITECTURE

REPLACE FIRE ALARM SYSTEM

565-20-201

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMC

GI001

EXF

COVER SHEET ISSUED FOR

CONSTRUCTION

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 06-29-2022

CO

CH

RA

N

AV

E.

FA

CI

RAMSEY ST.

FA

CI

RAMSEY ST.

CO

CH

RA

N

AV

E.

P2

P3

P4

P5

P6

P7

P8

P9

P10

P13

P11

P12

P15

P14

P19

P18

P17

P20

P16 A WING B WING C WING D WING

8FO

8FO

FO,8V,4S,4A

2FO,8V,4S,4A

FO

FO

FO,V,S,A

V,S,A

2FO

FO

2FO

2V,S,A

4V,2S,2A

2V,S,A

2V,S,A

FO

FO

FO,V,S,A

FO

V,S,A

3V,S,A

FO

FO

P1

P20

P20

P20

P20

FO

2FO TO REMAIN UNSPLICED AND

COILED IN BOX FOR FUTURE

EXPANSION TO FISHER HOUSE

AND MRI BUILDINGS.

PHASING NOTES

BUILDINGS WILL BE BROUGHT ONLINE IN THE

FOLLOWING ORDER:

1. BUILDING 1 (FACP ONLY)

2. BUILDING 9

3. BUILDING 10

4. BUILDING 34

5. BUILDING 35

6. BUILDING 11

7. BUILDING 3

8. BUILDING 21

9. BUILDING 4

10. BUILDING 50

11. BUILDING 57

12. BUILDING 48

13. BUILDING 45

14. BUILDING 46

15. BUILDING 47

16. BUILDING 73

17. BUILDING 70

18. BUILDING 71

19. BUILDING 72

20. BUILDING 1

20.1. D-WING

20.2. C-WING

20.3. B-WING

20.4. A-WING

P1 PHASE ORDER NUMBER

GENERAL NOTES

1. BUILDING 1 NEW HEAD-END EQUIPMENT WILL

BE USED AS THE MAIN NETWORK NODE

WITHOUT ALTERING THE SYSTEM.

2. BUILDING 1 WILL BE BROKEN UP INTO

VERTICAL NOTIFICATION ZONES BASED ON

LOCATION OF FIRE AND SMOKE

COMPARTMENT SEPARATIONS ON LEVELS

ABOVE BASEMENT. REPLACEMENT SHALL

BEGIN FROM TOP FLOOR AND WORK DOWN

THE BUILDING WITH BASEMENT BEING LAST

FLOOR TO BE COMPLETED SO THAT

NOTIFICATION CAN BE FED FROM PROPER

ZONE ABOVE.

3. BUILDING 1 WILL BE REPLACED BY VERTICAL

EVACUATION ZONE ACCORDINGLY:

D WING

C WING

B WING

A WING

EXISTING UNDERGROUND

PATHWAY

NEW 2" UNDERGROUND

PATHWAY

NEW 2" CONDUIT

PATHWAY

WIRE LEGEND

FO = 12 STRAND FIBER OPTIC CABLE (SINGLE MODE)

A = 16/2 THWN (SLC)

V = 14/2 THWN (NAC, STROBE)

S = 16/2 THWN (SPEAKER)

*NETWORK AND CABLE ROUTING IS DIAGRAMMATIC IN

NATURE. CONTRACTOR MUST FIELD-VERIFY EXACT

WIRE ROUTING PRIOR TO INSTALLATION.

CRM EXF

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

WEST POINT

ENGINEERING ARCHITECTURE

REPLACE FIRE ALARM SYSTEM

565-20-201

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMC

GI002

EXF

SITE PLAN - PHASING ORDER ISSUED FOR

CONSTRUCTION

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 06-29-2022

DENTAL LAB

B79H

TREATMENT

RM

B79F

TREATMENT

RM

B79E

TREATMENT

RM

B79B

CORRIDOR

B79I

TREATMENT

RM

B79D

TREATMENT

RM

B79C

CORRIDOR

B79A

CORRIDOR

B79

DENTAL SVC

MECH

B78

ELECTRICAL

B33

TELECOM

CLOSET

B32A

HOUSEKEEPING

STORAGE

B32

OFFICE

B30

RADIOLOGY

RM

B72

DENTAL X-RAY

B31

STORAGE

CLOSET

B29A

DOCTOR

OFFICE

B29

FEMALE

TOILET

B28 DOCTOR

OFFICE

B27

CHIEF

DENTAL

OFFICE

B26

FEC

SUPPLY

B62L

DENTAL SERVICE BREAK

RM

B62A

EXAM

B62K

CORRIDOR

B62

EXAM

B62J

EXAM

B62I

EXAM

B54L

B54I

OFFICE

B62F

EXAM

B62E

OFFICE

B62D

EXAM

B54H

EXAM

B54G

EXAM

UP

TREATMENT

RM

B54F

STORAGE

B62C

STORAGE

B62B

EXAM

B54E

TREATMENT RM

B54M CORRIDOR

B54

OFFICE

B54D

OFFICE

B54N

CORRIDOR

CAB-1

ELECTRICAL

B61-A

RECEPTION

B63

WAITING RM

B25

STAFF

TOILET

B61

HOUSEKEEPING

B24

EMS

DENTAL RESIDENT

OFFICE

B23

TRAINING /

LOCKER RM

B22

FEC

OFFICE

54P TREATMENT

RM

54C

SUPPLY

B31A

RADIOLOGY

RM

B73

ELEVATOR ELEVATOR

CORRIDOR

CAB-2

A WING

STAIR

B35

AEGD DIR

OFFICE

B36

OCCUPATIONAL

HEALTH

OFFICE

B37

ELECTRICAL

MALE TOILET

B38

LINEN

CHUTE

B85

SOILED LINEN

B39

CLEAN LINEN

B40

CRAMER

ASSOC

CHIEF OF

PHARMACY

OFFICE

B21

LOBBY

AUDIOLOGY /

CARDIOLOGY /

GASTROENTEROLOGY

WAITING

B41

TREATMENT

B79L

EXAM

B42A

ELECTRICAL

CLOSET

B41A

CORRIDOR

B34

EXAM

B79K

NURSE

OFFICE

B42B

CARDIOLOGY

CORRIDOR

B42

OFFICE

B42K

STAIR

B43

CORRIDOR

CB-2

PHARMACY

OFFICE

B44

STORAGE

CORRIDOR

CBB-1

PVA

OFFICE

B20 RECEPTION

B19

OFFICE

B54A

VACANT

B18B

SPEECH

THERAPY

WAITING

B18

OFFICE

B18A

ASSISTANT

CHIEF EMS

OFFICE

B17

ARMS

RM

B14C

OFFICE

B16

GATE

OFFICE

B15 POLICE

OFFICE

B14

HOLDING

CELL

B14B

CHIEF OF

POLICE

B13

POLICE

DISPATCH

OFFICE

B12

EMS

B11

POLICE

ADMINISTRATION

B14-A

CORRIDOR

CCB-1

PHARMACY

OFFICE

B45

EMS SUPPLY RM

B47

DENTAL

STORAGE

B46

CORRIDOR

CBB-4

ELEVATOR

POLICE

TRAINING

RM

B06

ELEVATOR

POLICE

OFFICE

B07

POLICE

DETECTIVE

B08

OPHTHALMOLOGY

EXAM

B09

B WING STAIR

B01

FEC ELEVATOR

MSA RM

RECEPTION

B42J

EMS

CHIEF

OFFICE

B02

COOLER

B05A

EXAM

B42C

FEC

EXAM

B42D

STORAGE

B42-I

CANTEEN

STORAGE

B04

CORRIDOR

CBB-4

CORRIDOR

B42

READING RM

B42H MORGUE

B05

EXAM

B42E

STAFF TOILET

B42F

EKG EXAM

B42G

TREATMENT

RM

B79G

FC

CANTEEN

RECEIVING

B04A

PIV

F E

E

S E

S E

C

S E

C S E

F E

S E

C

S E

C

S E

C

E

FATC

S E

S E

C

F E

S E

C

TS

E

TS

E

FC

P

E

FATC

S E

S E

C

E

S E

C

S E

C

F E

S E

C

S E

C

DH

E

DH

E

S E

E

S E

C

E

S E

D

S E

S E

C

S E

E

F E

S E

C

E

S E

C

S E

C

E

S E

C

S E

E

E

S E

C

S E

C

FATC

F E

S E

C

S E

C

E

S E

C

S E

C

S E

C

S E

C

S E

F E

S E

DH

E

DH

E

S E

E

F E

S E

C

S E S

E

C

S E

DH

DH

S

E

C

S E

E

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA102)

M

ATCHLIN

E (FA101)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA101

BUILDING 1 BASEMENT

SCALE:

BUILDING 1 BASEMENT FLOOR PLAN - EXISTING

1/8" = 1' 0"1

FIRE ALARM PLAN - EXISTING

DOCTOR

OFFICE

PRACTITIONER

OFFICE(SLEEP

DOSORDER

CLINIC)

0079-D

NURSE

NURSE

OFFICE

0079-F

I V RM

UNDER UNDER UNDER

STORE RM

0077-M

UNIT BASE AREA

0077-L

STAFF

TOILET

0077-I

ALPHA CLINIC

INFUSION

AREA

0063B

NURSING

ALPHA CLINIC

EXAM RM

RESPIRATORY

OFFICE

NURSING

OFFICE

UNDER

UNDER

CONSTRUCTION

CONSTRUCTION

UNDER

CONSTRUCTION

STAFF

TOILET

0057-A

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

UNDER CONSTRUCTION

CB-7

SPECIALITY

CLINIC

OFFICE

0079-H

OFFICE

0079-G

COPY RM

0079-1

UNDER

CONSTRUCTION

0077-O

PREP

RM

OO77G-1

OFFICE

0079-C

UNDER

CONSTRUCTION

0077-D

UNISEX

TOILET

0063D

CHECK IN

0063A

UNDER

UNDER CONSTRUCTION

CONSTRUCTION

OFFICE

0079-K FC

OFFICE

0079-M

DELTA

CLINIC

NURSES

OFFICE

0079-B

STORAGE

0063G

CORRIDOR

0063INFUSION CLINIC

ONCOLOGY CLINIC

OFFICE

0077Q

OFFICE WORK

RM

0077-K

ANTE

RM

0077-G EXAM

0063F

UNISEX

TOILET

0063E

STAFF

TOILET

0062-A

EMS

STORAGE

WAITING

NURSING

EXAM

RM

SOCIAL WORKER

OFFICE

DAV

OFFICE

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

UNDER

UNDER

CONSTRUCTION

0055-A

CONSTRUCTION

0055-B

EXAM

0063C

CORRIDOR

CB-10BCORRIDOR

CB-9

ONCOLOGY

OFFICE

CORRIDOR

CB-8

UNDER

CORRIDOR

CB-10

UNDER

CONSTRUCTION

0055-C

CONSTRUCTION

CB-10A

UNDER

CONSTRUCTION

0031-A

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

CB-5

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

0031B

UNDER

CONSTRUCTION

EMS

B11 CHECK IN

0079-K

PULMONARY/

RESPIRATORY

CARE

WAITING

0079-A

VAULT

0077-A1

UNDER

CONSTRUCTION

0077-B

VAULT

0077-A

PHARMACY

UNDER

CONSTRUCTION

0077-C

PHARMACY

WAITING

CB-11A

CORRIDOR

CB-11A

OPHTHALMOLOGY

EXAM

B09

CORRIDOR

CB-12

UP

STAIRS

B10

DN

LOUNGE

MALE LOCKER

80-B

COMMON

CLOSET

TB-1

FEMALE

LOCKER

80-C

FEMALE TOILET

0076-B

MALE

TOILET

0076-A DRESSING

RM

ELECTRICAL

CLOSET

EB-1

SPD

STORAGE

0074J

STORAGE

DECONTAMINATION

B081

CART WASH

0081-C

UTILITY

RM

0080-C

OFFICE

0068-B

OFFICE

0074-A

SUPPLY

RM

0074-B

EXAM RM

LAU 5

0074-C

CORRIDOR

CB-15

WORK

RM

0074-H

WORK

RM

0074-G

WAITING

0074-I

CORRIDOR

CB-11A

OUT-PATIENT

DROP/

PRESCRIPTION

OFFICE

0077-P FISCAL

CASHIER

RESPIRATORY

CARE

OFFICE

OFFICE

WAITING RM

ONCOLOGY

OFFICE

STARBUCKS

HAC

FEMALE

TOILET

0030 UNDER

CONSTRUCTION

CB-6

UNDER

CONSTRUCTION

0032B

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

WOTKERS

COMPENSATION

PROGRAM

OFFICE

CANTEEN

STORAGE

0053-A

CART

STORAGE

0054A UNISEX

TOILET

UNDER

CONSTRUCTION

STAIR-6

S-206

MALE

TOILET

UNDER

CONSTRUCTION

CORRIDOR

CB-11A TELECOM

CLOSET

TB-2

EB-2

INFORMATION

OFFICE

ER

STORAGE

0027-A

FEC

CORRIDOR

CB-11A

EXAM RM

LAU 4

0074-D

EXAM RM

LAU 3

0074-E

EXAM RM

LAU 2

0074-F

0068-G

EXAM RM

LAU 1

0067 ELEVATOR ELEVATOR

NURSE

MGR

ASSISSTANT

OFFICE

ELEVATOR

MACHINE RM

STAFF

TOILET

TRIAGE

RM-2

BREAK RM

LOCKER

0026-A

STAFF

TOILET

0026-B

0028A WAITING

TRIAGE

RM-1

BAY-1

BAY-2

BAY-3

CORRIDOR STORAGE

0028-A

SPD

FC

STORAGE /

SUPPLY

0068-A DUMBWAITER BREAK RM

0024A

CORRIDOR CORRIDOR

CB-3

BAY 4

ISOLATION RM

STERILIZERS

FC

OFFICE

0068-C

NURSE MGR

OFFICE

HSKP

CLEAN UTILITY

0007-A

TOILET-1

0009-B

VESTIBULE

0009-A

ANTE

RM

ER CHECK IN

0006 NURSE STATION

AERATOR

CLEAN RM

0068-D ELEVATOR

MECH RM

0068-F

MECH

EMERGENCY RM

WAITING

EMERGENCY

GENERATOR

EB-2

COMPRESSOR

RM

0068-H

CORRIDOR

CB-1

DRY

UTILITY

PATIENT

SHOWER

TOILET-2

NOURISH

COUNTER

CORRIDOR

CB-2

BAY-4

ISOLATION

RM

0016A

BAY-6

MECH

MER-1

MECH /

ELECTRICAL

EB-1

MALE

TOILET

B0004

FEMALE

TOILET

DN HAC

MB-3 STAIR

S005

POLICE / SECURITY

RM

0002 EMERGENCY

ENTRANCE

BAY-10 ACUTE

RM

BAY-9

BAY-8

SUPPLY

TOILET 3

0011-A

BAY-7

OBSERVATION RM

CORRIDOR

CB-11A

OUTPATIENT

ENTRANCE

0028B

C O

R R

ID

O

R

U N

D

ER

C O

N

ST

R U

C

TI

O N

A

U N

D

ER

C O

N

ST

R U

C

TI

O N

-A

F E

S E

S E

S E

C

S E

S E

DH

E

DH

E

S E

C

S E

E S

E

C

S E

C

S E

C

E

S E

C

E

S E

C

E

E

E

E

E

E

S E

C S

E

C S E

C S E

C

H E

F E

F E

E

E

S E

S E

S E

S E

E

S E

C S

E

C

F E

E

C

E

S E

C

E

S E

E

E

E

S E

S E

CS

E

C

S E

C

S E

C

E

E S E

E

S E

S E

S E

C S

E

C

FEC

E

S E

C

S E

C

S E

C

S E

C

S E

C

DH

E

DH

E

S E

E

S E

S E

E

C

E

E

S E

S E

C

E

S E

C

F E

E

S E

S

ES

E

C

S E

C

E

S E

E

E

E

S E

S E

S E

S E

S E

E

DH

E

DH

E

S E

S E

C

E E

C

E

TS

E

WF

E

DH

E

DH

E

S E

C

ES

E

S E

S E

F E

FACP

N

AC

FATC

FATC

S

EH E H E

S E

E

E

E

E

E

S E

E

S E

E S

E

F E

S E

S E

EE

E

N

AC

NAC

S E

S E

S E

S E

S E

S E

S E

S E

S E

E

E

E

E

E

E S

E

S E

E

E

E

E

E

E

S E

C

S E

S E

E

E

FAA

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA102)

M

ATCHLIN

E (FA101)

MATCHLINE

MATCHLINE

MATCHLINE

MATCHLINE

U N

D

ER

C O

N

ST

R U

C

TI

O N

-B

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

C B-

A

M

EC

H U

N D

ER

C

O N

ST

R

U C

TI

O

N

-A

FE

C

U N

D

ER

C O

N

ST

R U

C

TI

O N

EB

-5

D O

G W

O O

D C

LI

N

IC

U N

D

ER

C O

N

ST

R U

C

TI

O N

C B-

U N

D

ER

C O

N

ST

R U

C

TI

O N

C B-

B

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

U N

D

ER

U N

D

ER

C O

N

ST

R U

C

TI

O N

C O

N

ST

R U

C

TI

O N

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

U N

D

ER

C O

N

ST

R U

C

TI

O N

M

AT

CH

LI

N E

M

AT

CH

LI

N E

M

AT

CH

LI

N E

M

AT

CH

LI

N E

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA102

BUILDING 1 BASEMENT

SCALE:

BUILDING 1 BASEMENT FLOOR PLAN - EXISTING

ST

O

R

AG

E

H O

U

SE

KE

EP

IN

G

OFFICE

OFFICE

OFFICE

TO BUILDING 03

OFFICE

HAS

BREAK RM

FILE RM

IT

CHIEF OF URGENT

CARE OFFICE

MALE TOILET

A116

ELECTRICAL

ELECTRICAL

CONFERENCE RM

CHIEF NURSE

GERIATRICS

AND EXTENDED

CARE

CHIEF NURSE

MEDICINE

NURSE

RECRUITER

OFFICE

DEPUTY

ASSOCIATE

DIR PATIENT

CARE SVC

SEC / RECPT

CHIEF NURSE

SURGERY

OFFICE

BREAK RM

CONFERENCE RM

145 MENS TOILET

143A

P AND R SUPER

LEAD HR SPLT

OPEN OFFICES

STORAGE

141A

STORAGE

137-B

CHIEF OF

CHAPLAIN SVC

FEMALE TOILET

EXAM RM 2

115-L

OPEN OFFICES PATIENT CARE

SERVICES STAFF

TBI CASE

MGR OFFICE

115-K

CHAPEL

EXAM RM 4

115-J

CHAPLAIN OFFICE

137-A

FEMALE

TOILET

135 TBI NURSE

PRACTITIONER

EXAM

115-M

STORAGE

137-C

MALE

TOILET

CAROLINA EXECUTIVE

CONFERENCE RM

ADVOCATE

OFFICE

ADVOCATE

OFFICE

LOBBY

OFFICE

VACANT

128 OFFICE

127 ELECTRICAL

128-A

PGM ADVOCATE

OFFICE

115-N

MECH

CORRIDOR

C1AN

ELECTRICAL

FEC

CORRIDOR

C1AS

ELECTRICAL

E133 TOILET

132-A

IRM CLOSET

190-B1

TELEPHONE

CLOSET

190-B CORRIDOR

ELEVATOR ELEVATOR

MECH

175A

VACANT

CHAPLAIN

OFFICE

177 HR ASST (P AND R)

OFFICE

CONFERENCE

RM

180 NURSING SVC

ADMIN OFFICE

181-A

SECRETARY

OFFICE

STAIR

175 OFFICE

UNISEX

TOILET

A117

STAIR

TOILET

190-A

ASSOCIATE

DIR OFFICE

(OPERATION)

190 ELEVATOR

ELEVATOR

COMMUNICATION OFFICE

OFFICE

DECEDENT

AFFAIRS

HEALTH

BENEFITS AND

TRAVEL OFFICE

ASSOCIATE DIR OF

NURSING

181-B

CORRIDOR

ADMIN OFFICE

HEALTH SYSTEMS

SPECIALIST FOR

OPERATION

STORAGE

102-A

STAIR

FEC ELEVATOR

TELECOM

CLOSET

OFFICE

112-A

STAIR

(OPERATION) LEAF

COORDR OFFICE

VACANT

PIV OFFICE

102 EEO OFFICE

106-A

CHIEF OFFICE

(CHIEF OF RM 184)

185 PIV OFFICE

OFFICE

112-B

VETERANS CANTEEN

SVC CONFESSION

OFFICE

EEO MGR OFFICE

STAFF

TOILET

112-D

EEO OFFICE

106 OFFICE

112-C

OFFICE

EMPLOYEE

AND LABOR

RELATION

SPECIALIST

112-E

E

E

E

E

E

E

E

E

E

E

S E

E E

E

C

E

E

S E

FATC

E

F E

E

E

E

E

E

D

E

E

NAC

E

E E

S E

S E

E E

E E

E

E

E

E

DH

E

S E

C

C

E

E

E

E

S E

C

S E

C

F E

E

S E

C

S E

C

S E

FACP

S E

E

D

E

S E

C S

E

C

C

E S

E

C S E

S E

S E

C

E

F E

S E

S E

DH

E

DH

E

S E S E S

E

C S

E

C

FA

C

P

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA104)

M

ATCHLIN

E (FA103)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA103

BUILDING 1 FIRST FLOOR

SCALE:

BUILDING 1 FIRST FLOOR PLAN - EXISTING

C

R R

ID

O

R C

1- 2B

ST

O

R

AG

E

C O

R R

ID

O

R

LO

C

KE

R

IMAGING SVC MGR OFFICE

1013-B

IMAGING SVC

SUPERVISOR

1013-A

EXAM RM 2

115-L

TBI CASE

MGR OFFICE

115-K

EXAM RM 4

115-J EXAM RM 5

115-I

PM AND RS

SERVICE

CHIEF

OFFICE

115-H

LOUVER WINDOW STORAGE

1043-C

HISTOLOGY

ENGG

STORAGE

CORRIDOR

EXAM RM 7

115-G

WORK RM

1046B

OFFICE

1046-A

LAB

1043-A

LAB

1043-B

WORK RM

BREAK RM

CONTRACT

SUPPLIES

1041A

FC

CHIEF

PATHOLOGIST

OFFICE

1040A

CORRIDOR

TBI NURSE

PRACTITIONER

EXAM

115-M

EXAM RM 8

115-F

MECH

MER 21

MICROBIOLOGY

HEMATOLOGY

LAB

PATHOLOGY

OFFICE

OFFICE

127 ELECTRICAL

128-A

PGM ADVOCATE

OFFICE

115-N RECEPTIONIST

115-C

STORAGE

115-B

DIGITAL IMAGING

OCT OCULAR

PHOTOGRAPHIC

STORAGE

115-E

EXAM

115-D

LOUVER WINDOW

BLOOD BANK

UNISEX

BARIATRIC

TOILET

1052A

WOMENS

TOILET

1053A

CONFERENCE

RM

TBI CLINIC 115-A

PRIVACY

OFFICER

MALE TOILET

FEMALE TOILET

FEC

ELECTRICAL

LAB

WAITING/RECEPTION AREA

CORRIDOR

C1-10

BAY-4

1054D

BAY-5

1054E

BAY-6

1054F

OFFICE

MENS

TOILET

1050A

CORRIDOR

MENS

TOILET

1051A

CORRIDOR

C1-11

PHLEBOTOMY AREA

CORRIDOR

C1-13

PHLEBOTOMY

STORAGE

BAY-1

1054A

BAY-2

1054B

BAY-3

1054C

OFFICE

MALE

TOILET

1035-A

MALE

LOCKER

FEMALE

TOILET

1036-A

FEMALE

LOCKER

CORRIDOR

C1-1

TELEPHONE

CLOSET

TL-2

UP DN

OFFICE

DECEDENT

AFFAIRS

HEALTH

BENEFITS AND

TRAVEL OFFICE

TBI CLINIC WAITING

114 OFFICE

OFFICE

112-A

STAIR

HR OFFICE

112-K

RECEPTION OFFICE

HOUSEKEEPING

DRESSING

RM

1006-B

EXAM

TOILET

1006-A

DRESSING

RM

1006-C

OFFICE

1015A

IMAGING

WAITING

T-1-1

CHECK IN

ELEVATOR ELEVATOR

ELECTRICAL

E-1-1 EMS STORAGE

ELECTRICAL

E1-2

OFFICE

112-B

BIO-HAZARD

INFECTIOUS

WASTE

1011-B DRESSING

RM

1011-B1

EXAM

DRESSING

RM

1010-A

EXAM

CORRIDOR

TOILET

1010B

FC

CHIEF OFFICE

RADIOLOGY

1021-E

PATIENT REP

OFFICE

PATIENT CLOTHING

AND EFFECTS

RELEASE OF INFO OFFICE

OFFICE NUCLEAR

MEDICINE SECY

1021-F

X-RAY RM

DRESSING

RM

1007-B

DRESSING

RM

1007-A

UNISEX

TOILET

PATIENT PREP

1024A

WAITING

CONTROL

1024C

EXAM RM / MRI

MACH

STAFF

TOILET

112-D

OFFICE

112-C

CORRIDOR

1310 CONFERENCE RM

112-J

STORAGE

112-I

CORRIDOR

STORAGE

112-H ULTRASOUND

1012UNISEX TOILET

1011-A

WORK RM

1015-C

OFFICE

EMPLOYEE

AND LABOR

RELATION

SPECIALIST

112-E

FILE RM

112-F

EMPLOYEE

ANDLABOR

RELATIONS

SPECIALIST

112-G

OFFICE CORRIDOR

ULTRASOUND

EXAM RM

1012-A

ULTRASOUND

EXAM RM

1012-B

STORAGE

1015-B1

READING

RM

1015-A IMAGING

STORAGE

1017 CORRIDOR CT SCAN

BREAK RM

DRESSING

RM

1024B

CT SCAN

CONTROL

1022A

SEALED OFFICE

1015-B

VIEWING RM

1015-C

STAFF

RADIOLOGY

STAFF

RADIOLOGY

UNISEX

TOILET

SUPPLY

1029C

CT SCAN

WAITING

1022B

MECH

EQUIP

HOT LAB

1021-B

IV RM

1021-C

DRESSING

RM

1029A

MAMMOGRAPHY SUITE

SECY

RADIOLOGY SVC

CT

OFFICE

1014A

CT SCAN

1014B

CONTROL

RM

1014C

CT EQUIP RM

1014D CLOSET

1014E

DR IN WALL

CLOTHS

STORAGE

1019 CT STORAGE

UNISEX

TOILET

1029B

STAIR - 9

4-DUP

DN

TECH RM

1021-A NUCLEAR

MEDICINE

IMAGING RM

CONTROL

BULK HEAD

STORAGE

SUPPLY

1022-C

CORRIDOR

NUCLEAR

MEDICINE

IMAGING RM

1021A

STORAGE

1021-C1

NUCLEAR MEDICINE

WAITING

1021K

STAIR

S-106

LAB SECY

OFFICE

SUPPLY

IM

AGIN

G R M

S E

C

F E

E

E

S E

C

E

E

E

F E

S E S E

C DH

E

DH

E

S E

FA

C

P

S E

C

S E

C

S E E

E

S E

C S

E

C S

E

C

FEC

S EFA

C

P

S E

S E

S E

S E

S E

S E

C E

S E

S

EE

E

F E

E

S E

C S

E

C S

E

C

S E

C

S E

CS

E

C

S E

C S

E

C S

E

C

S E

C

E S

E

S E

E

S E E

S E S E

E

E

FEC

S E

C

S E

C

S E

C

S E

C

S E

C

S E

C

E

S E

C

E

S E S E

C

E

C

E

DH

E

DH

E

S E

C S

E

C

NAC

S E S

E

C

S E

S E

C

S E

C

DH

EDH

E

S E

DH

EDH

E

S E C

E

E E

E E

C

E

S E

S E

C

E

DH

E

DH

E

E

F E

E

S E

S E

C

E S

E

C

S E

C

S E

S E

S E

E

S E

C

S E

C

F E

TS

E

WF

E

S E

E

E

E

S E

S E

C

S E

C

S E

E

TS

E

WF

E

S E

S E

N

AC

S E

S E

FSC

U

S E

S E

C

FEC

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA104)

M

ATCHLIN

E (FA103)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA104

BUILDING 1 FIRST FLOOR

SCALE:

BUILDING 1 FIRST FLOOR PLAN - EXISTING

OFFICE

OFFICE

OFFICE

UNDER CONSTRUCTION

OFFICE

OFFICE

OFFICE

OFFICE

264 CORRIDOR

C2AE

OFFICE

OFFICE

263 OFFICE

PATIENT RM

ISOLATION

PATIENT

TOILET

286A

OFFICE

OFFICE

OFFICE

FC

OFFICE

OFFICE

ELECTRICAL

260 STAIR

ELEVATOR

CLASSROOM

STORAGE

ELEVATOR

MECH

STORAGE

SOILED

UTILITY

MEDICATION RM

STAIR

PATIENT RM

EQUIPMENT

STORAGE

CLEAN

UTILITY

PATIENT

TOILET

283A

CORRIDOR

C2A

STAFF

BREAK

TOILET

257A

TOILET

WAITING

RM

TOILET

255A

NURSE STATION

NOURISHMENT

MEDICATION

RM

NURSE WORK RM

PATIENT

TOILET

248A

PATIENT

TOILET

252A

PATIENT RM

PATIENT RM

248 PATIENT

TOILET

237A

PATIENT RM

PATIENT

TOILET

251A PATIENT

TOILET

236A

PATIENT RM

PATIENT

TOILET

250A

PATIENT

TOILET

249A

PATIENT RM

PATIENT RM

PATIENT

TOILET

235A

PATIENT RM

ISOLATION

PATIENT RM

ANTE RM

236B

CORRIDOR

2AC1

PATIENT

TOILET

238A

HOUSEKEEPING

ELECTRICAL

PATIENT RM

PATIENT

TOILET

6'-97

PATIENT RM

PATIENT

TOILET

242A

PATIENT RM

STORAGE

PATIENT

TOILET

241A

PUBLIC

TOILET

PATIENT RM

238 PATIENT

TOILET

233A

PATIENT

TOILET

234A

CORRIDOR

2BC4

PATIENT RM

PATIENT RM

FEC

TELECOM

ELECTRICAL

PATIENT

RM

PATIENT

TOILET

231A

PATIENT

TOILET

230A

PATIENT

RM

TELEMETRY

NURSE

STATION

PUBLIC

TOILET

227A

WAITING

SOILED

UTILITY

CLEAN

UTILITY

NOURISHMENT

MED RM

CORRIDOR

TELECOM

291 MECH

ELEVATOR

STORAGE

MECH

STAIR

ELEVATOR

ELEVATOR

NOURISHMENT

FOOD NUTRITION

201-A

PATIENT RM

BARIATRIC

CORRIDOR

2BC3

PATIENT RM

CORRIDOR

C2EE

PATIENT

TOILET

285A

PATIENT

TOILET

288A

FOOD NUTRITION

DIETICIANS

FOOD

PATIENT

TOILET

287A

FOOD NUTRITION

NUTRITION

ANTE RM

286B

PATIENT RM

TO

B

U

IL

D

IN

G

E

E

E F E

E

E

S E

FATC

S E

E

E

E

C

E

C

E

E

E

S E

E E

E

C

E

E S

E S E

C

S E

C

S E

C

F E

S E

DH

E

DH

E

E E

E

E S

E

S E

E

FATC

N

AC

E

NAC

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA106)

M

ATCHLIN

E (FA105)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA105

BUILDING 1 SECOND FLOOR

SCALE:

BUILDING 1 SECOND FLOOR PLAN - EXISTING

PATIENT RM

PATIENT RM

217B

CORRIDOR

PATIENT

TOILET

219A

PATIENT

TOILET

218A

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT

TOILET

217A

CORRIDOR

ANTE RM

PATIENT RM

PATIENT RM

TOILET

2310-A

WAITING

HALL

MALE

TOILET

FAMILY

CONSULT

FEMALE

TOILET

PATIENT

RM

PATIENT RM

PATIENT RM

PATIENT

TOILET

216A PATIENT RM

NURSE

STATION

RESP

WORK RM

CONFERENCE

RM

SOILED

UTILITY

CORRIDOR

C2.14

OFFICE

OFFICE

RECEPTION

ELECTRICAL

UNISEX

TOILET

DN

STAIR

#7

S.207

STORAGE

PATIENT

TOILET

215A

NOURISHMENT

MED RM

HAC

ELECTRICAL

ELECTRICAL

PATIENT RM

NUTRITION

TO D WING

PATIENT

TOILET

2301-A

PATIENT RM

PATIENT RM

2301-A ANTE

RM

LINEN

ICU

WAITING

UNISEX

TOILET

2321-A

CORRIDOR

C2.11

HSA

PHYSICIAN

WORK

2051 ANESTHESIA

WORK RM

STORAGE

CORRIDOR

C2.12

STORAGE

STAIR-6

S-206

PRE-OP

PRE-OP

PRE-OP

PRE-OP

PRE-OP

CORRIDOR

C2.1 ELECTRICAL

MECH

PATIENT RM

STAIR

STORAGE

SOILED

UTILITY

TOILET

222-A

SCRUB

DATA

CLOSET

T2.1

FC TELEPHONE

CLOSET

T2-2

CORRIDOR

C2.8

CORRIDOR

C2.13

UP DN

STORAGE

PATIENT

RM

TOILET

217-A

TOILET

216-A

PATIENT RM

CORRIDOR

MECH

CORRIDOR

C2.2

MALE

LOCKER

EQUIP

OR-4

ELEVATOR

P-5

ELECTRICAL

F2-1

ELEVATOR

P-6

STORAGE

HAC

PHASE

NURSE

MGR

OR-5

CO-ORDINATOR

OFFICE

FEMALE

LOCKER

PHASE

TOILET

220-A

INSTRUMENT

PROC.

DUMB

WAITER

CLEAN

CORE

SCRUB

SUB STERILE

CORRIDOR

C2.6

HAC

MED

RM

CORRIDOR

C2.7 STAFF

TOILET

CORRIDOR

C2.9

SOILED

UTILITY

NOURISHMENT

PACU

CLEAN

UTILITY

UNISEX

TOILET

NURSE

STATION

PHASE 2

PHASE

CONFERENCE

RM

PATIENT

RM

TOILET

219-A

BREAK

RM

2008B

SUB

STERILE

CORRIDOR

C2.3

OR-1

OR-2

OR-3

STORAGE

STORAGE

PACU

NURSE

STATION

PACU

FAMILY

RM

PATIENT RM

MECH

MER.3

CORRIDOR

C2.5

SCRUB

SUB STERILE

CORRIDOR

C2.4

SCRUB

2020 PACU

PACU

PACU

ISOLATION

PACU

DICTATION

UP

STAIR-5

S-205

STORAGE

C O

R R

ID

O

R

E

E S

E

S E

E

S E

E S E

S E

S E

S E

C

S E

C

F E

S E

FEC

S E S E

DH

E

DH

E

C

E

C

E

E

FATC

N

AC

E

E

C

E

S E

C S

E

C

E

E

C

E

C

E

C

E

E

E

C

E

C

E

S E

F E

E

E

C

E

C

E

S E

C C

E C

E

C

E

C

E

F E

E E E

E

C

E

C

E

E

C

E

C

E

C

E

C

E

C

E

E

E

E

S E

RTS

RTS

RTS

RTS RTS

RTS

RTS

RTS

C

E

C

E

C

E

E

E

E

RTS

C

E

F E

TS

E

TS

E

TS

E

WF

E

WF

E

C

E

C

E

C

E

C

E

C

E

C

E

C

E

E

E

EE

E

E

E

F E

S E

CS

E

C S

E

C

S E

C

S E

C

E

E

FEC

FEC

S E

DH

E

DH

E

RTS

RTS

RTS

RTS

E

E

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA106)

M

ATCHLIN

E (FA105)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA106

BUILDING 1 SECOND FLOOR

SCALE:

BUILDING 1 SECOND FLOOR PLAN - EXISTING

KITCHEN

NOURISH

392-A

PATIENT RM

PATIENT

TOILET

374-A

PATIENT RM

374 PATIENT

TOILET

376-A

PATIENT RM

TOILET

372-A

PATIENT RM

PATIENT RM

PATIENT

TOILET

368-A

CORRIDOR

C300-C

PATIENT RM

PATIENT RM

367 PATIENT

TOILET

367-A

DICTATION

PATIENT RM

TOILET

363-A

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT

TOILET

359-A

PATIENT RM

PATIENT RM

PATIENT RM

360 PATIENT

TOILET

340-A

PATIENT RM

PATIENT RM

342 PATIENT RM

CORRIDOR

C300-B

PATIENT

TOILET

342-A

PATIENT RM

PATIENT TOILET

338-A

PATIENT RM

MED RM

NURSES STATION

MALE / FEMALE

TOILET

ELECTRICAL

KITCHEN

NOURISH

CORRIDOR

C300-A

CLEAN LINEN

SPD STORAGE

ANTE RM

367-B

PATIENT RM

ANTE RM

370-B

ELEVATOR LOBBY

FC STAIR

PATIENT

TOILET

380A

PATIENT

TOILET

381-A

SOILED

LINEN

HOPPER FC HOUSEKEEPING

CORRIDOR

BATH RM

337 NURSE MGR

FEC

ELECTRICAL

UNISEX TOILET

335-A

PATIENT

TOILET

370-A

ELEVATOR ELEVATOR PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT

TOILET

384-A

TELECOM

CLOSET

STAIR

WARD

STORAGE

CORRIDOR

C300-D

SHOWER

ELECTRICAL

378 OFFICE

392-C

DAY RM

PATIENT RM

CONFERENCE

RM

392-B

PA

TI

EN

T

TO

IL

ET

1- A

C O

U N

TE

R

D

ES

K

S E

S E

C

E

S E

S E

FEC

E

FACP

F E

S E

S E E

E

S E

S E

C

E

S E

S E S E

S E

C

E

S E

C

S E

S E F E

E DH

E

DH

E

S E

S E

E

S E

C

E

F E

S E

E

S ES

E

C

E

E

S E

S E

S E

C

S E

C

S E

FACP

FATC

NAC

E

S E

C

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA108)

M

ATCHLIN

E (FA107)

FIRE ALARM LEGEND

NFPA 170 VA DESCRIPTION

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

NOTIFICATION CIRCUIT POWER

BOOSTER, EXTENDER PANEL

N = UNIT NUMBER

RELEASING SERVICE CONTROL UNIT

TYPE - WET CHEMICAL

ELEVATOR STATUS/RECALL

FIRE ALARM ANNUNCIATOR

FIRE SUPPRESSION CONTROL UNIT

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

ADDRESSABLE DUAL INPUT MODULE

MANUAL FIRE ALARM BOX

WET CHEMICAL

DOOR HOLD OPEN

POST INDICATOR VALVE

FLOW SWITCH

TAMPER SWITCH

SMOKE DETECTOR

IN DUCT SMOKE DETECTOR *

DUCT SMOKE DETECTOR *

DUCT INDICATOR

HEAT DETECTOR

MANUAL PULL STATION

HALON PULL STATION

HORN STROBE - CEILING

HORN STROBE - WALL

SPEAKER STROBE - CEILING

SPEAKER STROBE - WALL

SPEAKER - CEILING

SPEAKER - WALL

STROBE - CEILING

STROBE - WALL

GONG

ADDRESSABLE CONTROL RELAY (AT

ACCESS CONTROL POWER SUPPLY

FOR MAGLOCK DOOR RELEASE)

FACP

FATC

NACn

RSFACU

WC

ESR

FAA

FSCU

AOM

AIM

AIM

WC

DH

PIV

WF

E

TS

S

S ID

S

RTS

H

F

HL

C

C

S C

S

E

CD

F G

CR

AC

NEW

EXISTING

N

E

DEVICE ABBREVIATIONS

DEMOLISHD

REPLACER

C

E CEILING

CANDELA

RATING

EXISTING

NOTIFICATION SYMBOL

LEGEND

*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR

AHU SHUTDOWN

ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE

ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE

DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR

ADJACENT TO THE CONTROLLERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA107

BUILDING 1 THIRD FLOOR

8' 0 4' 8' 16'

SCALE 1/8" = 1'-0"

PLAN

NORTH

SCALE:

BUILDING 1 THIRD FLOOR PLAN - EXISTING

392-A

PATIENT RM

TOILET

326-A

PATIENT

TOILET

340-A

PATIENT RM

340 PATIENT RM

PATIENT RM

PATIENT RM

342 PATIENT RM

TOILET

324-A

PATIENT RM

PATIENT

TOILET

342-A

PATIENT RM

PATIENT TOILET

338-A

PATIENT RM

PATIENT RM

HOUSEKEEPING

CORRIDOR

BATH RM

337 NURSE MGR

GERIATRIC

SVC OFFICE

334-A

PRACTITIONER

OFFICE

NURSE MGR

NURSE LOUNGE

TOILET

331-A PATIENT RM

FEC

ELECTRICAL

UNISEX TOILET

335-A

CORRIDOR

HOUSEKEEPING

TELECOM

CLOSET

STAIR

WARD

STORAGE

HOUSEKEEPING

LOCKERS

STAIR

301 ELEVATOR

TOILET

309-A

NOURISHMENT KITCHEN

ANTE RM

331-B

STAFF TOILET

330-A

SOILED UTILITY

CLEAN LINEN

311-C NURSES STATION

311B

CORRIDOR

C300-A

(MEDICAL SURGICAL WARD)

VESTIBULE

330-B

ELECTRICAL

TOILET

328-A

TOILET

322-A

PATIENT RM

STORAGE

MED RM

311-A

STAIR

ELEVATOR STORAGE

PATIENT RM

TELE MEDICINE

311-A

PATIENT RM

FC FC

WINDOW CAN'T SEE IN RM

OFFICE

392-C

MEDICINE ADMIN

OFFICER MED SVC

SVC

ELEVATOR TOILET

319-A

PATIENT RM

PATIENT RM

DAY RM

MEDICINE TELEHEALTH

LEAD CARE CO-ORDR

OFFICE

302-A

CORRIDOR

CHIEF MED SVC

304-B

SECY MED SVC

304-A

TOILET

313-A

PATIENT RM

CORRIDOR

C300-B

MED SVC OFFICE

303-A

PGM SPECIALIST

MED SVC

CONFERENCE

RM

392-B

PATIENT RM

TOILET

317-A

TO BLDG 3

TOILET

315-A

PATIENT RM

PATIENT RM

PATIENT RM

PATIENT RM

328 CORRIDOR

C300-C PATIENT RM

C O

U N

TE

R

D

ES

K

E

E DH

E

DH

E

S E

S E

E

S E

C

E

F E

S E

E

S ES

E

C

E

E

S E

S E

S E

C

S E

C

S E

FACP

FATC

NAC

E

S E

C

E

S E

C

S E

C

S E

C

F E

S E

E

DH

E

DH

E

S E

S E

C

S E

C S

E

C

S E

C

S E

C

S E

C

S E

C

S E

C

E

E

S E

S EFA

C

P

F E

F E

S E

E

E

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA108)

M

ATCHLIN

E (FA107)

FIRE ALARM LEGEND

NFPA 170 VA DESCRIPTION

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

NOTIFICATION CIRCUIT POWER

BOOSTER, EXTENDER PANEL

N = UNIT NUMBER

RELEASING SERVICE CONTROL UNIT

TYPE - WET CHEMICAL

ELEVATOR STATUS/RECALL

FIRE ALARM ANNUNCIATOR

FIRE SUPPRESSION CONTROL UNIT

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

ADDRESSABLE DUAL INPUT MODULE

MANUAL FIRE ALARM BOX

WET CHEMICAL

DOOR HOLD OPEN

POST INDICATOR VALVE

FLOW SWITCH

TAMPER SWITCH

SMOKE DETECTOR

IN DUCT SMOKE DETECTOR *

DUCT SMOKE DETECTOR *

DUCT INDICATOR

HEAT DETECTOR

MANUAL PULL STATION

HALON PULL STATION

HORN STROBE - CEILING

HORN STROBE - WALL

SPEAKER STROBE - CEILING

SPEAKER STROBE - WALL

SPEAKER - CEILING

SPEAKER - WALL

STROBE - CEILING

STROBE - WALL

GONG

ADDRESSABLE CONTROL RELAY (AT

ACCESS CONTROL POWER SUPPLY

FOR MAGLOCK DOOR RELEASE)

FACP

FATC

NACn

RSFACU

WC

ESR

FAA

FSCU

AOM

AIM

AIM

WC

DH

PIV

WF

E

TS

S

S ID

S

RTS

H

F

HL

C

C

S C

S

E

CD

F G

CR

AC

NEW

EXISTING

N

E

DEVICE ABBREVIATIONS

DEMOLISHD

REPLACER

C

E CEILING

CANDELA

RATING

EXISTING

NOTIFICATION SYMBOL

LEGEND

*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR

AHU SHUTDOWN

ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE

ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE

DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR

ADJACENT TO THE CONTROLLERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA108

BUILDING 1 THIRD FLOOR

8' 0 4' 8' 16'

SCALE 1/8" = 1'-0"

PLAN

NORTH

SCALE:

BUILDING 1 THIRD FLOOR PLAN - EXISTING

PATIENT

TOILET

471-A

PATIENT RM

PATIENT RM

FC

PATIENT

TOILET

473-A

OFFICE

PATIENT RM

PATIENT

TOILET

469-A

ELECTRICAL

CLOSET

CORRIDOR

C400-D

STORAGE

OFFICE

487 CORRIDOR

OFFICE

HEAD

NURSE

OFFICE

PATIENT RM

PATIENT RM

PATIENT

TOILET

467-A

CORRIDOR

C400-C

PATIENT RM

PATIENT RM

465-A

PATIENT RM

TOILET

462-B

PATIENT

TOILET

461-A

PATIENT RM

PATIENT RM

PATIENT

TOILET

459-A

PATIENT RM

PATIENT RM

PATIENT

TOILET

457-A

FC

CABINET BELOW

CORRIDOR

C400-B

PATIENT RM

4A DAY RM

ANTE RM

462-A

NURSE

CONFERENCE RM

456 ASSISTANT

CHIEF

OFFICE

447-A

DAYROOM KITCHENETTE

CHIEF

OFFICE

PATIENT RM

MED RM

CORRIDOR

C400-3

NURSE STATION

ELECTRICAL

STAFF TOILET

NOURISHMENT

KITCHEN

CLEAN LINEN

STORAGE

ELEVATOR LOBBY

463-4

SHAFT

PATIENT RM

ELEVATOR ELEVATOR PATIENT RM

PATIENT

TOILET

478-A

PATIENT RM

PATIENT

TOILET

479-A

SOILED

UTILITY

FC HOUSEKEEPING

ELECTRICAL

CLOSET

A434

CORRIDOR

CORRIDOR FEMALE

TOILET

OFFICE

INTERIOR

DESIGN

OFFICE

488-A

TELECOM

CLOSET

PATIENT RM

SHAFT

PATIENT

TOILET

482-A

COUNSELING RM

SHAFT

FP

PATIENT RM

LOCKERS

484-B

ADMIN

OFFICE

485-A TELECOM

CLOSET

DWGS

STORAGE

DECON

STORAGE

STAIR

OFFICE

STAIR WELL

STORAGE

OFFICE

OFFICE

PATIENT RM

OFFICE

MENS

TOILET

OFFICE

E

FA

TC

N

AC

S ES

E

C

E

RTS

S E

S E

C

RTS

E

S E

S E

S E

FATC

F E

S E

S E

C

S E

C

S E

C

S E

C

S E

C S

E

C

S E

S E

S E

S E

E

RTS

E

S E

S E S E

S E

E

S E

S E

S E S

E

C

F E E

DH

E

DH

E

S E S E

S ES E

S E

S E

C

S E

C

S E

C

S E

C

E

E

E

S E

S E

E

C

E

F G

E

S E

E

E

E

E

F E

S E

C

S E

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA110)

M

ATCHLIN

E (FA109)

FIRE ALARM LEGEND

NFPA 170 VA DESCRIPTION

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

NOTIFICATION CIRCUIT POWER

BOOSTER, EXTENDER PANEL

N = UNIT NUMBER

RELEASING SERVICE CONTROL UNIT

TYPE - WET CHEMICAL

ELEVATOR STATUS/RECALL

FIRE ALARM ANNUNCIATOR

FIRE SUPPRESSION CONTROL UNIT

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

ADDRESSABLE DUAL INPUT MODULE

MANUAL FIRE ALARM BOX

WET CHEMICAL

DOOR HOLD OPEN

POST INDICATOR VALVE

FLOW SWITCH

TAMPER SWITCH

SMOKE DETECTOR

IN DUCT SMOKE DETECTOR *

DUCT SMOKE DETECTOR *

DUCT INDICATOR

HEAT DETECTOR

MANUAL PULL STATION

HALON PULL STATION

HORN STROBE - CEILING

HORN STROBE - WALL

SPEAKER STROBE - CEILING

SPEAKER STROBE - WALL

SPEAKER - CEILING

SPEAKER - WALL

STROBE - CEILING

STROBE - WALL

GONG

ADDRESSABLE CONTROL RELAY (AT

ACCESS CONTROL POWER SUPPLY

FOR MAGLOCK DOOR RELEASE)

FACP

FATC

NACn

RSFACU

WC

ESR

FAA

FSCU

AOM

AIM

AIM

WC

DH

PIV

WF

E

TS

S

S ID

S

RTS

H

F

HL

C

C

S C

S

E

CD

F G

CR

AC

NEW

EXISTING

N

E

DEVICE ABBREVIATIONS

DEMOLISHD

REPLACER

C

E CEILING

CANDELA

RATING

EXISTING

NOTIFICATION SYMBOL

LEGEND

*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR

AHU SHUTDOWN

ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE

ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE

DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR

ADJACENT TO THE CONTROLLERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA109

BUILDING 1 FOURTH FLOOR

8' 0 4' 8' 16'

SCALE 1/8" = 1'-0"

PLAN

NORTH

SCALE:

BUILDING 1 FOURTH FLOOR PLAN - EXISTING

OFFICE

487 CORRIDOR

OFFICE

BATH RM

419A

SLEEP RM 5

PHYSICIAN

OFFICE

CABINET BELOW

SLEEP RM 4

BATH RM

420A

STORAGE

417A

4A DAY RM

SLEEP RM 3

ASSISTANT

CHIEF

OFFICE

447-A

DAYROOM KITCHENETTE

CHIEF

OFFICE

BATH RM

421A

SLEEP RM 2

EMS

BATH RM

421A

CLOSET

417B

SLEEP RM 1

ELECTRICAL

CLOSET

A434

CORRIDOR

CORRIDOR

BATH RM

421A

SOILED

UTILITY

417C

STAFF

TOILET

417D

FEMALE

TOILET

OFFICE

INTERIOR

DESIGN

OFFICE

SAFETY

MGR

OFFICE

BIOMED

SUPERVISOR

OFFICE

BIOMED

WORK RM

DIRTY

RM

ELECTRICAL

TESTING/LAB

488-A

STORAGE

DATA

CLOSET

RECEPTION

TELECOM

CLOSET

COUNSELING RM

SHAFT

FP

CORRIDOR

C4BSS

SHAFT

CORRIDOR

CONTROL

LOCKERS

484-B

ADMIN

OFFICE

485-A TELECOM

CLOSET

DWGS

STORAGE

DECON

STORAGE

CORRIDOR

C4EE

STORAGE

EOC FILE RM

FM SVC

ELEVATOR

PASSENGER

MENS

TOILET

HAC

OFFICE

STAIR WELL

STORAGE

OFFICE

SHAFT FEC

STAIR

SVC

ELEVATOR

STAIR

WOMENS

TOILET

SAFETY OFFICE

STORAGE

SLEEP RM 6

BATH RM

410A VISITOR

TOILET

408A

ROOF

CLEAN

SLEEP RM 7

411 BATH RM

411A

STORAGE

408B

SLEEP RM 8

BATH RM

412A

OFFICE

OFFICE

MENS

TOILET

OFFICE

SLEEP RM 9

BATH RM

413A

CLEAN

LINEN

408C

BATH RM

414A

SLEEP RM 10

OFFICE

FA

TC

N

AC

E E

DH

E

DH

E

S E S E

S ES E

S E

S E

C

S E

C

S E

C

S E

C

E

E

E

S E

S E

E

C

E

F G

E

S E

E

E

E

E

F E

S E

C

S E

C S

E

C

S E

C

S E

C

S E

C

S E

C

S E

C

S E

C

S E

S E S E

F E

E

FACP

E

E

E

E

E

S E

C

S E

C

S E

C

S E

C

F E

E

E

E

S E

S E

E

E

S E

TS

E

WF

E

FA

TC

N

AC

E

E

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA110)

M

ATCHLIN

E (FA109)

FIRE ALARM LEGEND

NFPA 170 VA DESCRIPTION

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

NOTIFICATION CIRCUIT POWER

BOOSTER, EXTENDER PANEL

N = UNIT NUMBER

RELEASING SERVICE CONTROL UNIT

TYPE - WET CHEMICAL

ELEVATOR STATUS/RECALL

FIRE ALARM ANNUNCIATOR

FIRE SUPPRESSION CONTROL UNIT

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

ADDRESSABLE DUAL INPUT MODULE

MANUAL FIRE ALARM BOX

WET CHEMICAL

DOOR HOLD OPEN

POST INDICATOR VALVE

FLOW SWITCH

TAMPER SWITCH

SMOKE DETECTOR

IN DUCT SMOKE DETECTOR *

DUCT SMOKE DETECTOR *

DUCT INDICATOR

HEAT DETECTOR

MANUAL PULL STATION

HALON PULL STATION

HORN STROBE - CEILING

HORN STROBE - WALL

SPEAKER STROBE - CEILING

SPEAKER STROBE - WALL

SPEAKER - CEILING

SPEAKER - WALL

STROBE - CEILING

STROBE - WALL

GONG

ADDRESSABLE CONTROL RELAY (AT

ACCESS CONTROL POWER SUPPLY

FOR MAGLOCK DOOR RELEASE)

FACP

FATC

NACn

RSFACU

WC

ESR

FAA

FSCU

AOM

AIM

AIM

WC

DH

PIV

WF

E

TS

S

S ID

S

RTS

H

F

HL

C

C

S C

S

E

CD

F G

CR

AC

NEW

EXISTING

N

E

DEVICE ABBREVIATIONS

DEMOLISHD

REPLACER

C

E CEILING

CANDELA

RATING

EXISTING

NOTIFICATION SYMBOL

LEGEND

*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR

AHU SHUTDOWN

ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE

ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE

DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR

ADJACENT TO THE CONTROLLERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA110

BUILDING 1 FOURTH FLOOR

8' 0 4' 8' 16'

SCALE 1/8" = 1'-0"

PLAN

NORTH

SCALE:

BUILDING 1 FOURTH FLOOR PLAN - EXISTING

TEAM RM

OFFICE

OFFICE

OFFICE

OFFICE

ELEVATOR MIC RM

ELEVATOR

SWITCHGEAR

DN CHUTE

FECMED.CART

STORAGE

NURSE STATION

LOCK DOWN UNIT

CRASH CART

STORAGE

BED RM-20

BATH-20

567A

BATH-19

566A

BED RM-19

CORRIDOR

C5-10

BED RM-15

BED RM-18

BATH-18

565A

BATH-17

564A

BED RM-17

BATH-16

563A

BED RM-16

BATH-15

562A

DAYRM

DINING RM

(LOCK DOWN

UNIT)

TELECOM RM

544-A

STAFF

TOILET-2

CORRIDOR

C5-9

CORRIDOR

C5BS

PATIENT RM

OFFICE

OFFICE

CORRIDOR

C5BN

DN

STORAGE

OFFICE

MALE

TOILET

OFFICE

STAIR

FEMALE TOILET

S E

S E

S E

S E

S E

S E

S E

S E

S E

S E

S E

E

E

E

E

C

H E H E

H E H E

S E

ES

R

E

F E

S E

TS

E

WF

E

E

C

E

C

FATC

NAC

S E

C

E

S E

C

S E

C

S E

E

E

E

S E

S E

F E

S E

S ES E

S E S E

S E

S E

S E

E

E

S E

C

S E

C

S E

C

E

S E

F EE

C

E

S E E

E

S E

C

E

E

S E

C S E

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA112)

M

ATCHLIN

E (FA111)

FIRE ALARM LEGEND

NFPA 170 VA DESCRIPTION

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

NOTIFICATION CIRCUIT POWER

BOOSTER, EXTENDER PANEL

N = UNIT NUMBER

RELEASING SERVICE CONTROL UNIT

TYPE - WET CHEMICAL

ELEVATOR STATUS/RECALL

FIRE ALARM ANNUNCIATOR

FIRE SUPPRESSION CONTROL UNIT

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

ADDRESSABLE DUAL INPUT MODULE

MANUAL FIRE ALARM BOX

WET CHEMICAL

DOOR HOLD OPEN

POST INDICATOR VALVE

FLOW SWITCH

TAMPER SWITCH

SMOKE DETECTOR

IN DUCT SMOKE DETECTOR *

DUCT SMOKE DETECTOR *

DUCT INDICATOR

HEAT DETECTOR

MANUAL PULL STATION

HALON PULL STATION

HORN STROBE - CEILING

HORN STROBE - WALL

SPEAKER STROBE - CEILING

SPEAKER STROBE - WALL

SPEAKER - CEILING

SPEAKER - WALL

STROBE - CEILING

STROBE - WALL

GONG

ADDRESSABLE CONTROL RELAY (AT

ACCESS CONTROL POWER SUPPLY

FOR MAGLOCK DOOR RELEASE)

FACP

FATC

NACn

RSFACU

WC

ESR

FAA

FSCU

AOM

AIM

AIM

WC

DH

PIV

WF

E

TS

S

S ID

S

RTS

H

F

HL

C

C

S C

S

E

CD

F G

CR

AC

NEW

EXISTING

N

E

DEVICE ABBREVIATIONS

DEMOLISHD

REPLACER

C

E CEILING

CANDELA

RATING

EXISTING

NOTIFICATION SYMBOL

LEGEND

*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR

AHU SHUTDOWN

ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE

ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE

DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR

ADJACENT TO THE CONTROLLERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA111

BUILDING 1 FIFTH FLOOR

8' 0 4' 8' 16'

SCALE 1/8" = 1'-0"

PLAN

NORTH

SCALE:

BUILDING 1 FIFTH FLOOR PLAN - EXISTING

BED RM-3

TEAM RM

BATH-2

511A

OFFICE

BATH-1

510A

OFFICE

OFFICE

OFFICE

FECMED.CART

STORAGE

NURSE STATION

LOCK DOWN UNIT

CRASH CART

STORAGE

BED RM-20

BATH-20

567A

BATH-19

566A

BED RM-19

CORRIDOR

C5-10

BED RM-15

BED RM-18

BATH-18

565A

BATH-17

564A

BED RM-17

BATH-16

563A

BED RM-16

563 BED RM-12

BATH-11

523A

BED RM-11

BATH-15

562A

BATH-12

524A

BATH-13

525A

BED RM-13

CORRIDOR

C5-4

BED RM-9

BED RM-10

BATH-10

522A

DAYRM

DINING RM

(LOCK DOWN

UNIT)

BATH-9

521A

TELECOM RM

544-A

STAFF

TOILET-2

CORRIDOR

C5-9

CORRIDOR

C5-8

CORRIDOR

C5BS

PATIENT RM

SOILED

UTILITY

541 HAC

PATIENT

STORAGE

STORAGE

RM-2

539-B

CORRIDOR

C5-7

CORRIDOR

C5-13

NOUR

INTERVIEW RM

GROUP RM

STATION

CRASH CART

ALCOVE

CORRIDOR

C5-5

BED RM-14

BATH-14

526A

ELECTRICAL

STORAGE RM-1

NURSE STATION

OPEN UNIT

DAYRM /

DINING RM

(OPEN UNIT)

FIRE EQUIP

OFFICE

OFFICE

CORRIDOR

C5BN

DN

PATIENTSTORAGE

OFFICE

RESIDENT OFFICE

BELONGINGS

STORAGE

CORRIDOR

C5EE

ELEVATOR

ELEVATOR

STAFF

TOILET-1

501A STAFF BREAK

RM AND

STAFF

LOCKER AREA

DICTATION

HEAD NURSE

OFFICE

MED SUPPLIES

CORRIDOR

C5-2

EXAM

CHASE

EXAM RM

TOILET

517A

MALE

TOILET

OFFICE

STAIR

STAIR

FEC ELEVATOR

BED RM-1

BATH-7

516A

STAIR

BED RM-7

BED RM-6

BATH-6

515A

FEMALE TOILET

552 BED RM-2

BATH-5

514A

BED RM-5

BATH-3

512A

BED RM-4

BATH-4

513A

BED RM-8

BATH-8

520A

LA

U

N D

R Y

2B

S E

C

E

S E

C

S E

C

S E

E

E

E

S E

S E

F E

S E

S ES E

S E S E

S E

S E

S E

E

E

S E

C

S E

C

S E

C

E

S E

F EE

C

E

S E E

E

S ES

E

C

E

E

S E

C S

E

C S E

S E

E E

E

S E

S E

S E

S E

S E

S E

S E

DH

E

DH

E

E E

E

S E

C

E

E

F E

S E

C

S E

S E

C

E

E

S E

S E

C

E E

S E S E

S E S E

S E

S E

C

E

E

E

E F E

E

FATC

S E

S E

C

E

S E

S E

C

S E

S E

C

S E

S E

C

S E

S E

C

S E

S E

C

E

E

E

KR

E

E

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA112)

M

ATCHLIN

E (FA111)

FIRE ALARM LEGEND

NFPA 170 VA DESCRIPTION

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

NOTIFICATION CIRCUIT POWER

BOOSTER, EXTENDER PANEL

N = UNIT NUMBER

RELEASING SERVICE CONTROL UNIT

TYPE - WET CHEMICAL

ELEVATOR STATUS/RECALL

FIRE ALARM ANNUNCIATOR

FIRE SUPPRESSION CONTROL UNIT

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

ADDRESSABLE DUAL INPUT MODULE

MANUAL FIRE ALARM BOX

WET CHEMICAL

DOOR HOLD OPEN

POST INDICATOR VALVE

FLOW SWITCH

TAMPER SWITCH

SMOKE DETECTOR

IN DUCT SMOKE DETECTOR *

DUCT SMOKE DETECTOR *

DUCT INDICATOR

HEAT DETECTOR

MANUAL PULL STATION

HALON PULL STATION

HORN STROBE - CEILING

HORN STROBE - WALL

SPEAKER STROBE - CEILING

SPEAKER STROBE - WALL

SPEAKER - CEILING

SPEAKER - WALL

STROBE - CEILING

STROBE - WALL

GONG

ADDRESSABLE CONTROL RELAY (AT

ACCESS CONTROL POWER SUPPLY

FOR MAGLOCK DOOR RELEASE)

FACP

FATC

NACn

RSFACU

WC

ESR

FAA

FSCU

AOM

AIM

AIM

WC

DH

PIV

WF

E

TS

S

S ID

S

RTS

H

F

HL

C

C

S C

S

E

CD

F G

CR

AC

NEW

EXISTING

N

E

DEVICE ABBREVIATIONS

DEMOLISHD

REPLACER

C

E CEILING

CANDELA

RATING

EXISTING

NOTIFICATION SYMBOL

LEGEND

*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR

AHU SHUTDOWN

ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE

ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE

DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR

ADJACENT TO THE CONTROLLERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA112

BUILDING 1 FIFTH FLOOR

8' 0 4' 8' 16'

SCALE 1/8" = 1'-0"

PLAN

NORTH

SCALE:

BUILDING 1 FIFTH FLOOR PLAN - EXISTING

MECH

S E

S E

E

E

C

TS

E

WF

E

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA114)

M

ATCHLIN

E (FA113)

FIRE ALARM LEGEND

NFPA 170 VA DESCRIPTION

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

NOTIFICATION CIRCUIT POWER

BOOSTER, EXTENDER PANEL

N = UNIT NUMBER

RELEASING SERVICE CONTROL UNIT

TYPE - WET CHEMICAL

ELEVATOR STATUS/RECALL

FIRE ALARM ANNUNCIATOR

FIRE SUPPRESSION CONTROL UNIT

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

ADDRESSABLE DUAL INPUT MODULE

MANUAL FIRE ALARM BOX

WET CHEMICAL

DOOR HOLD OPEN

POST INDICATOR VALVE

FLOW SWITCH

TAMPER SWITCH

SMOKE DETECTOR

IN DUCT SMOKE DETECTOR *

DUCT SMOKE DETECTOR *

DUCT INDICATOR

HEAT DETECTOR

MANUAL PULL STATION

HALON PULL STATION

HORN STROBE - CEILING

HORN STROBE - WALL

SPEAKER STROBE - CEILING

SPEAKER STROBE - WALL

SPEAKER - CEILING

SPEAKER - WALL

STROBE - CEILING

STROBE - WALL

GONG

ADDRESSABLE CONTROL RELAY (AT

ACCESS CONTROL POWER SUPPLY

FOR MAGLOCK DOOR RELEASE)

FACP

FATC

NACn

RSFACU

WC

ESR

FAA

FSCU

AOM

AIM

AIM

WC

DH

PIV

WF

E

TS

S

S ID

S

RTS

H

F

HL

C

C

S C

S

E

CD

F G

CR

AC

NEW

EXISTING

N

E

DEVICE ABBREVIATIONS

DEMOLISHD

REPLACER

C

E CEILING

CANDELA

RATING

EXISTING

NOTIFICATION SYMBOL

LEGEND

*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR

AHU SHUTDOWN

ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE

ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE

DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR

ADJACENT TO THE CONTROLLERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA113

BUILDING 1 PENTHOUSE FLOOR

8' 0 4' 8' 16'

SCALE 1/8" = 1'-0"

PLAN

NORTH

SCALE:

BUILDING 1 PENTHOUSE FLOOR PLAN - EXISTING

STAIR

ELEVATOR MACHINE RM

UP

MECH

SWITCH GEAR

DN

MECH PENT

S E

S E

S E

S E

S E

E

E

F E

E

C

E

C

TS

E

WF

E

TS

E

WF

E

ES E

H E

H E

ESR

E

RTS

S E

M

AT

CH

LI

N E

(F A1

M

AT

CH

LI

N E

(F A1

M

ATCHLIN

E (FA114)

M

ATCHLIN

E (FA113)

FIRE ALARM LEGEND

NFPA 170 VA DESCRIPTION

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

NOTIFICATION CIRCUIT POWER

BOOSTER, EXTENDER PANEL

N = UNIT NUMBER

RELEASING SERVICE CONTROL UNIT

TYPE - WET CHEMICAL

ELEVATOR STATUS/RECALL

FIRE ALARM ANNUNCIATOR

FIRE SUPPRESSION CONTROL UNIT

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

ADDRESSABLE DUAL INPUT MODULE

MANUAL FIRE ALARM BOX

WET CHEMICAL

DOOR HOLD OPEN

POST INDICATOR VALVE

FLOW SWITCH

TAMPER SWITCH

SMOKE DETECTOR

IN DUCT SMOKE DETECTOR *

DUCT SMOKE DETECTOR *

DUCT INDICATOR

HEAT DETECTOR

MANUAL PULL STATION

HALON PULL STATION

HORN STROBE - CEILING

HORN STROBE - WALL

SPEAKER STROBE - CEILING

SPEAKER STROBE - WALL

SPEAKER - CEILING

SPEAKER - WALL

STROBE - CEILING

STROBE - WALL

GONG

ADDRESSABLE CONTROL RELAY (AT

ACCESS CONTROL POWER SUPPLY

FOR MAGLOCK DOOR RELEASE)

FACP

FATC

NACn

RSFACU

WC

ESR

FAA

FSCU

AOM

AIM

AIM

WC

DH

PIV

WF

E

TS

S

S ID

S

RTS

H

F

HL

C

C

S C

S

E

CD

F G

CR

AC

NEW

EXISTING

N

E

DEVICE ABBREVIATIONS

DEMOLISHD

REPLACER

C

E CEILING

CANDELA

RATING

EXISTING

NOTIFICATION SYMBOL

LEGEND

*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR

AHU SHUTDOWN

ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE

ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE

DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR

ADJACENT TO THE CONTROLLERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FAYETTEVILLE

VA MEDICAL

CENTER

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

REPLACE FIRE ALARM SYSTEM

565-20-201

06-29-2022

2300 RAMSEY STREET, FAYETTEVILLE, NC 28301

FAYETTEVILLE VAMCWEST POINT

ENGINEERING ARCHITECTURE

REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF

BLDG 01

B1.FA114

BUILDING 1 PENTHOUSE FLOOR

8' 0 4' 8' 16'

SCALE 1/8" = 1'-0"

PLAN

NORTH

SCALE:

BUILDING 1 PENTHOUSE FLOOR PLAN - EXISTING

DENTAL LAB

B79H

TREATMENT

RM

B79F

TREATMENT

RM

B79E

TREATMENT

RM

B79B

CORRIDOR

B79I

TREATMENT

RM

B79D

TREATMENT

RM

B79C CORRIDOR

B79A

CORRIDOR

B79

DENTAL SVC

MECH

B78

ELEC.

B33

TELECOM

CLOSET

B32A

HK

STOR.

B32

OFFICE

B30

RADIOLOGY

RM

B72

DENTAL X-RAY

B31

CLOSET

B29A

DOCTOR

OFFICE

B29

FEMALE

TOILET

B28 DOCTOR

OFFICE

B27

CHIEF

DENTAL

OFFICE

B26

FEC

SUPPLY

B62L

DENTAL SERVICE

BREAK

RM

B62A

EXAM

B62K

CORRIDOR

B62

EXAM

B62J

EXAM

B62I

EXAM

B54L

B54I

OFFICE

B62F

EXAM

B62E

OFFICE

B62D

EXAM

B54H

EXAM

B54G

EXAM

UP

TREATMENT

RM

B54F

STORAGE

B62C

STORAGE

B62B

EXAM

B54E

TREATMENT RM

B54M CORRIDOR

B54

OFFICE

B54D

OFFICE

B54N

CORRIDOR

CAB-1

ELECTRICAL

B61-A

RECEPTION

B63 WAITING RM

B25

STAFF

TOILET

B61

HK

B24

EMS

DENTAL RESIDENT

OFFICE

B23

TRAINING /

LOCKER RM

B22

FEC

OFFICE

54P TREATMENT

RM

54C

SUPPLY

B31A

RADIOLOGY

RM

B73

ELEVATOR ELEVATOR

CORRIDOR

CAB-2

A WING

STAIR

B35

AEGD DIR

OFFICE

B36

OCCUPATIONAL

HEALTH

OFFICE

B37

ELECTRICAL

MALE TOILET

B38

LINEN

CHUTE

B85

SOILED LINEN

B39

CLEAN LINEN

B40

CRAMER

ASSOC

CHIEF OF

PHARMACY

OFFICE

B21

LOBBY

AUDIOLOGY /

CARDIOLOGY /

GASTROENTEROLOGY

WAITING

B41

TREATMENT

B79L

EXAM

B42A

ELECTRICAL

CLOSET

B41A

CORRIDOR

B34

EXAM

B79K

NURSE

OFFICE

B42B

CARDIOLOGY

CORRIDOR

B42

OFFICE

B42K

STAIR

B43

CORRIDOR

CB-2

PHARMACY

OFFICE

B44

STORAGE

CORRIDOR

CBB-1

PVA

OFFICE

B20 RECEPTION

B19

OFFICE

B54A

VACANT

B18B

SPEECH

THERAPY

WAITING

B18

OFFICE

B18A

ASSISTANT

CHIEF EMS

OFFICE

B17

ARMS

RM

B14C

OFFICE

B16

GATE

OFFICE

B15 POLICE

OFFICE

B14

HOLDING

CELL

B14B

CHIEF OF

POLICE

B13 POLICE

DISPATCH

OFFICE

B12

EMS

B11

POLICE

ADMINISTRATION

B14-A

CORRIDOR

CCB-1

PHARMACY

OFFICE

B45

EMS…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .