565-20-201 Replace Fire Alarm System - IFC Drawings.pdf
PDF 34 MB Posted
- Solicitation number
- 36C24623B0002
About this file
This document outlines a federal contract opportunity to replace the fire alarm system at a Department of Veterans Affairs medical center. The solicitation seeks bids to perform a site-wide replacement of existing fire alarm systems across the campus to provide a code-compliant, unified fire alarm platform in each building. The new system must be capable of minimal live voice paging and fully integrate with existing VA systems. The basis of design is a Siemens Desigo fire alarm system with graphics computer. Bids are due by the date specified in the solicitation number 36C24623B0002 from the Veterans Health Administration Veterans Integrated Service Network 6.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 0-FA06-FA Upgrade Campus Network Layout 2007.pdf | ||
| 0-FA05-FA Upgrade Campus Fiber Layout 2007.pdf | ||
| 36C24623B0002.docx | DOCX document | |
| 565-20-201 Combined Specifications Final Submission Update.pdf | ||
| Attachment A - Itemized Schedule of Values Cost Breakdown.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CO
CH
RA
N
AV
E.
FA
CI
LI
TY
D
R.
RAMSEY ST.
NORTH
FA
CI
RAMSEY ST.
CO
CH
RA
N
AV
E.
FUEL
PUMP
STATION
CRM EXF
GENERAL
GI001 COVER SHEET
GI002 SITE PLAN
FIRE ALARM:
BUILDING 1:
B1.FA101 BUILDING 1 BASEMENT FIRE ALARM PLAN - EXISTING
B1.FA102 BUILDING 1 BASEMENT FIRE ALARM PLAN - EXISTING
B1.FA103 BUILDING 1 FIRST FLOOR FIRE ALARM PLAN - EXISTING
B1.FA104 BUILDING 1 FIRST FLOOR FIRE ALARM PLAN - EXISTING
B1.FA105 BUILDING 1 SECOND FLOOR FIRE ALARM PLAN - EXISTING
B1.FA106 BUILDING 1 SECOND FLOOR FIRE ALARM PLAN - EXISTING
B1.FA107 BUILDING 1 THIRD FLOOR FIRE ALARM PLAN - EXISTING
B1.FA108 BUILDING 1 THIRD FLOOR FIRE ALARM PLAN - EXISTING
B1.FA109 BUILDING 1 FOURTH FLOOR FIRE ALARM PLAN - EXISTING
B1.FA110 BUILDING 1 FOURTH FLOOR FIRE ALARM PLAN - EXISTING
B1.FA111 BUILDING 1 FIFTH FLOOR FIRE ALARM PLAN - EXISTING
B1.FA112 BUILDING 1 FIFTH FLOOR FIRE ALARM PLAN - EXISTING
B1.FA113 BUILDING 1 PENTHOUSE FIRE ALARM PLAN - EXISTING
B1.FA114 BUILDING 1 PENTHOUSE FIRE ALARM PLAN - EXISTING
B1.FA115 BUILDING 1 BASEMENT FIRE ALARM PLAN - PROPOSED
B1.FA116 BUILDING 1 BASEMENT FIRE ALARM PLAN - PROPOSED
B1.FA117 BUILDING 1 FIRST FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA118 BUILDING 1 FIRST FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA119 BUILDING 1 SECOND FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA120 BUILDING 1 SECOND FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA121 BUILDING 1 THIRD FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA122 BUILDING 1 THIRD FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA123 BUILDING 1 FOURTH FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA124 BUILDING 1 FOURTH FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA125 BUILDING 1 FIFTH FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA126 BUILDING 1 FIFTH FLOOR FIRE ALARM PLAN - PROPOSED
B1.FA127 BUILDING 1 PENTHOUSE FIRE ALARM PLAN - PROPOSED
B1.FA128 BUILDING 1 PENTHOUSE FIRE ALARM PLAN - PROPOSED
B1.FA129 BUILDING 1 FIRE ALARM NOTES AND DIAGRAMS
B1.FA130 BUILDING 1 FIRE ALARM NOTES AND DIAGRAMS
B1.FA131 BUILDING 1 FIRE ALARM NOTES AND DIAGRAMS
BUILDING 3
B3.FA101 BUILDING 3 BASEMENT FIRE ALARM PLAN - EXISTING
B3.FA102 BUILDING 3 FIRST FLOOR FIRE ALARM PLAN - EXISTING
B3.FA103 BUILDING 3 SECOND FLOOR FIRE ALARM PLAN - EXISTING
B3.FA104 BUILDING 3 THIRD FLOOR FIRE ALARM PLAN - EXISTING
B3.FA105 BUILDING 3 FOURTH FLOOR FIRE ALARM PLAN - EXISTING
B3.FA106 BUILDING 3 BASEMENT FLOOR FIRE ALARM PLAN - PROPOSED
B3.FA107 BUILDING 3 FIRST FLOOR FIRE ALARM PLAN - PROPOSED
B3.FA108 BUILDING 3 SECOND FLOOR FIRE ALARM PLAN - PROPOSED
B3.FA109 BUILDING 3 THIRD FLOOR FIRE ALARM PLAN - PROPOSED
B3.FA110 BUILDING 3 FOURTH FLOOR FIRE ALARM PLAN - PROPOSED
B3.FA111 BUILDING 3 FIRE ALARM NOTES AND DIAGRAMS
BUILDING 4
B4.FA101 BUILDING 4 FIRE ALARM PLAN - EXISTING
B4.FA102 BUILDING 4 FIRE ALARM PLAN - PROPOSED
B4.FA103 BUILDING 4 FIRE ALARM NOTES AND DIAGRAMS
BUILDING 9
B9.FA101 BUILDING 9 FIRST FLOOR FIRE ALARM PLAN - EXISTING
B9.FA102 BUILDING 9 FIRST FLOOR FIRE ALARM PLAN - PROPOSED
B9.FA103 BUILDING 9 FIRE ALARM NOTES AND DIAGRAMS
BUILDING 10
B10.FA101 BUILDING 10 FIRE ALARM PLAN - EXISTING
B10.FA102 BUILDING 10 FIRE ALARM PLAN - PROPOSED
B10.FA103 BUILDING 10 FIRE ALARM NOTES AND DIAGRAMS
BUILDING 11
B11.FA101 BUILDING 11 FIRE ALARM PLAN - EXISTING
B11.FA102 BUILDING 11 FIRE ALARM PLAN - PROPOSED
BUILDING 21
B21.FA101 BUILDING 21 FIRST FLOOR FIRE ALARM PLAN - EXISTING
B21.FA102 BUILDING 21 FIRST FLOOR FIRE ALARM PLAN - PROPOSED
B21.FA103 BUILDING 21 NOTES AND DIAGRAMS
BUILDING 34
B34.FA101 BUILDING 34 FIRE ALARM PLAN - EXISTING
B34.FA102 BUILDING 34 FIRE ALARM PLAN - PROPOSED
BUILDING 35
B35.FA101 BUILDING 35 FIRE ALARM PLAN - EXISTING
B35.FA102 BUILDING 35 FIRE ALARM PLAN - PROPOSED
BUILDING 45
B45.FA101 BUILDING 45 FIRE ALARM PLAN - EXISTING
B45.FA102 BUILDING 45 FIRE ALARM PLAN - PROPOSED
B45.FA103 BUILDING 45 NOTES AND DIAGRAMS
BUILDING 46
B46.FA101 BUILDING 46 FIRE ALARM PLAN - EXISTING
B46.FA102 BUILDING 46 FIRE ALARM PLAN - PROPOSED
B46.FA103 BUILDING 46 NOTES AND DIAGRAMS
BUILDING 47
B47.FA101 BUILDING 47 FIRE ALARM PLAN - EXISTING
B47.FA102 BUILDING 47 FIRE ALARM PLAN - PROPOSED
B47.FA103 BUILDING 47 NOTES AND DIAGRAMS
BUILDING 48
B48.FA101 BUILDING 48 FIRE ALARM PLAN - EXISTING
B48.FA102 BUILDING 48 FIRE ALARM PLAN - PROPOSED
B48.FA103 BUILDING 48 NOTES AND DIAGRAMS
BUILDING 50
B50.FA101 BUILDING 50 FIRE ALARM PLAN - EXISTING
B50.FA102 BUILDING 50 FIRE ALARM PLAN - PROPOSED
B50.FA103 BUILDING 50 NOTES AND DIAGRAMS
BUILDING 57
B57.FA101 BUILDING 57 FIRE ALARM PLAN - EXISTING
B57.FA102 BUILDING 57 FIRE ALARM PLAN - PROPOSED
B57.FA103 BUILDING 57 NOTES AND DIAGRAMS
BUILDING 70
B70.FA101 BUILDING 70 FIRE ALARM PLAN - EXISTING
B70.FA102 BUILDING 70 FIRE ALARM PLAN - PROPOSED
B70.FA103 BUILDING 70 NOTES AND DIAGRAMS
BUILDING 71
B71.FA101 BUILDING 71 FIRE ALARM PLAN - EXISTING
B71.FA102 BUILDING 71 FIRE ALARM PLAN - PROPOSED
B71.FA103 BUILDING 71 NOTES AND DIAGRAMS
BUILDING 73
B73.FA101 BUILDING 73 FIRE ALARM PLAN - EXISTING
B73.FA102 BUILDING 73 FIRE ALARM PLAN - PROPOSED
B73.FA103 BUILDING 73 NOTES AND DIAGRAMS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
WEST POINT
ENGINEERING ARCHITECTURE
FAYETTEVILLE VAMC
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
PROJECT #565-20-201
REPLACE FIRE ALARM SYSTEM
U.S. Department of Veterans Affairs
WEST POINT ENGINEERS, LLC
ENGINEERING ARCHITECTURE
REPLACE FIRE ALARM SYSTEM
565-20-201
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMC
GI001
EXF
COVER SHEET ISSUED FOR
CONSTRUCTION
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 06-29-2022
CO
CH
RA
N
AV
E.
FA
CI
RAMSEY ST.
FA
CI
RAMSEY ST.
CO
CH
RA
N
AV
E.
P2
P3
P4
P5
P6
P7
P8
P9
P10
P13
P11
P12
P15
P14
P19
P18
P17
P20
P16 A WING B WING C WING D WING
8FO
8FO
FO,8V,4S,4A
2FO,8V,4S,4A
FO
FO
FO,V,S,A
V,S,A
2FO
FO
2FO
2V,S,A
4V,2S,2A
2V,S,A
2V,S,A
FO
FO
FO,V,S,A
FO
V,S,A
3V,S,A
FO
FO
P1
P20
P20
P20
P20
FO
2FO TO REMAIN UNSPLICED AND
COILED IN BOX FOR FUTURE
EXPANSION TO FISHER HOUSE
AND MRI BUILDINGS.
PHASING NOTES
BUILDINGS WILL BE BROUGHT ONLINE IN THE
FOLLOWING ORDER:
1. BUILDING 1 (FACP ONLY)
2. BUILDING 9
3. BUILDING 10
4. BUILDING 34
5. BUILDING 35
6. BUILDING 11
7. BUILDING 3
8. BUILDING 21
9. BUILDING 4
10. BUILDING 50
11. BUILDING 57
12. BUILDING 48
13. BUILDING 45
14. BUILDING 46
15. BUILDING 47
16. BUILDING 73
17. BUILDING 70
18. BUILDING 71
19. BUILDING 72
20. BUILDING 1
20.1. D-WING
20.2. C-WING
20.3. B-WING
20.4. A-WING
P1 PHASE ORDER NUMBER
GENERAL NOTES
1. BUILDING 1 NEW HEAD-END EQUIPMENT WILL
BE USED AS THE MAIN NETWORK NODE
WITHOUT ALTERING THE SYSTEM.
2. BUILDING 1 WILL BE BROKEN UP INTO
VERTICAL NOTIFICATION ZONES BASED ON
LOCATION OF FIRE AND SMOKE
COMPARTMENT SEPARATIONS ON LEVELS
ABOVE BASEMENT. REPLACEMENT SHALL
BEGIN FROM TOP FLOOR AND WORK DOWN
THE BUILDING WITH BASEMENT BEING LAST
FLOOR TO BE COMPLETED SO THAT
NOTIFICATION CAN BE FED FROM PROPER
ZONE ABOVE.
3. BUILDING 1 WILL BE REPLACED BY VERTICAL
EVACUATION ZONE ACCORDINGLY:
D WING
C WING
B WING
A WING
EXISTING UNDERGROUND
PATHWAY
NEW 2" UNDERGROUND
PATHWAY
NEW 2" CONDUIT
PATHWAY
WIRE LEGEND
FO = 12 STRAND FIBER OPTIC CABLE (SINGLE MODE)
A = 16/2 THWN (SLC)
V = 14/2 THWN (NAC, STROBE)
S = 16/2 THWN (SPEAKER)
*NETWORK AND CABLE ROUTING IS DIAGRAMMATIC IN
NATURE. CONTRACTOR MUST FIELD-VERIFY EXACT
WIRE ROUTING PRIOR TO INSTALLATION.
CRM EXF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
WEST POINT
ENGINEERING ARCHITECTURE
REPLACE FIRE ALARM SYSTEM
565-20-201
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMC
GI002
EXF
SITE PLAN - PHASING ORDER ISSUED FOR
CONSTRUCTION
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 06-29-2022
DENTAL LAB
B79H
TREATMENT
RM
B79F
TREATMENT
RM
B79E
TREATMENT
RM
B79B
CORRIDOR
B79I
TREATMENT
RM
B79D
TREATMENT
RM
B79C
CORRIDOR
B79A
CORRIDOR
B79
DENTAL SVC
MECH
B78
ELECTRICAL
B33
TELECOM
CLOSET
B32A
HOUSEKEEPING
STORAGE
B32
OFFICE
B30
RADIOLOGY
RM
B72
DENTAL X-RAY
B31
STORAGE
CLOSET
B29A
DOCTOR
OFFICE
B29
FEMALE
TOILET
B28 DOCTOR
OFFICE
B27
CHIEF
DENTAL
OFFICE
B26
FEC
SUPPLY
B62L
DENTAL SERVICE BREAK
RM
B62A
EXAM
B62K
CORRIDOR
B62
EXAM
B62J
EXAM
B62I
EXAM
B54L
B54I
OFFICE
B62F
EXAM
B62E
OFFICE
B62D
EXAM
B54H
EXAM
B54G
EXAM
UP
TREATMENT
RM
B54F
STORAGE
B62C
STORAGE
B62B
EXAM
B54E
TREATMENT RM
B54M CORRIDOR
B54
OFFICE
B54D
OFFICE
B54N
CORRIDOR
CAB-1
ELECTRICAL
B61-A
RECEPTION
B63
WAITING RM
B25
STAFF
TOILET
B61
HOUSEKEEPING
B24
EMS
DENTAL RESIDENT
OFFICE
B23
TRAINING /
LOCKER RM
B22
FEC
OFFICE
54P TREATMENT
RM
54C
SUPPLY
B31A
RADIOLOGY
RM
B73
ELEVATOR ELEVATOR
CORRIDOR
CAB-2
A WING
STAIR
B35
AEGD DIR
OFFICE
B36
OCCUPATIONAL
HEALTH
OFFICE
B37
ELECTRICAL
MALE TOILET
B38
LINEN
CHUTE
B85
SOILED LINEN
B39
CLEAN LINEN
B40
CRAMER
ASSOC
CHIEF OF
PHARMACY
OFFICE
B21
LOBBY
AUDIOLOGY /
CARDIOLOGY /
GASTROENTEROLOGY
WAITING
B41
TREATMENT
B79L
EXAM
B42A
ELECTRICAL
CLOSET
B41A
CORRIDOR
B34
EXAM
B79K
NURSE
OFFICE
B42B
CARDIOLOGY
CORRIDOR
B42
OFFICE
B42K
STAIR
B43
CORRIDOR
CB-2
PHARMACY
OFFICE
B44
STORAGE
CORRIDOR
CBB-1
PVA
OFFICE
B20 RECEPTION
B19
OFFICE
B54A
VACANT
B18B
SPEECH
THERAPY
WAITING
B18
OFFICE
B18A
ASSISTANT
CHIEF EMS
OFFICE
B17
ARMS
RM
B14C
OFFICE
B16
GATE
OFFICE
B15 POLICE
OFFICE
B14
HOLDING
CELL
B14B
CHIEF OF
POLICE
B13
POLICE
DISPATCH
OFFICE
B12
EMS
B11
POLICE
ADMINISTRATION
B14-A
CORRIDOR
CCB-1
PHARMACY
OFFICE
B45
EMS SUPPLY RM
B47
DENTAL
STORAGE
B46
CORRIDOR
CBB-4
ELEVATOR
POLICE
TRAINING
RM
B06
ELEVATOR
POLICE
OFFICE
B07
POLICE
DETECTIVE
B08
OPHTHALMOLOGY
EXAM
B09
B WING STAIR
B01
FEC ELEVATOR
MSA RM
RECEPTION
B42J
EMS
CHIEF
OFFICE
B02
COOLER
B05A
EXAM
B42C
FEC
EXAM
B42D
STORAGE
B42-I
CANTEEN
STORAGE
B04
CORRIDOR
CBB-4
CORRIDOR
B42
READING RM
B42H MORGUE
B05
EXAM
B42E
STAFF TOILET
B42F
EKG EXAM
B42G
TREATMENT
RM
B79G
FC
CANTEEN
RECEIVING
B04A
PIV
F E
E
S E
S E
C
S E
C S E
F E
S E
C
S E
C
S E
C
E
FATC
S E
S E
C
F E
S E
C
TS
E
TS
E
FC
P
E
FATC
S E
S E
C
E
S E
C
S E
C
F E
S E
C
S E
C
DH
E
DH
E
S E
E
S E
C
E
S E
D
S E
S E
C
S E
E
F E
S E
C
E
S E
C
S E
C
E
S E
C
S E
E
E
S E
C
S E
C
FATC
F E
S E
C
S E
C
E
S E
C
S E
C
S E
C
S E
C
S E
F E
S E
DH
E
DH
E
S E
E
F E
S E
C
S E S
E
C
S E
DH
DH
S
E
C
S E
E
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA102)
M
ATCHLIN
E (FA101)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA101
BUILDING 1 BASEMENT
SCALE:
BUILDING 1 BASEMENT FLOOR PLAN - EXISTING
1/8" = 1' 0"1
FIRE ALARM PLAN - EXISTING
DOCTOR
OFFICE
PRACTITIONER
OFFICE(SLEEP
DOSORDER
CLINIC)
0079-D
NURSE
NURSE
OFFICE
0079-F
I V RM
UNDER UNDER UNDER
STORE RM
0077-M
UNIT BASE AREA
0077-L
STAFF
TOILET
0077-I
ALPHA CLINIC
INFUSION
AREA
0063B
NURSING
ALPHA CLINIC
EXAM RM
RESPIRATORY
OFFICE
NURSING
OFFICE
UNDER
UNDER
CONSTRUCTION
CONSTRUCTION
UNDER
CONSTRUCTION
STAFF
TOILET
0057-A
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
UNDER CONSTRUCTION
CB-7
SPECIALITY
CLINIC
OFFICE
0079-H
OFFICE
0079-G
COPY RM
0079-1
UNDER
CONSTRUCTION
0077-O
PREP
RM
OO77G-1
OFFICE
0079-C
UNDER
CONSTRUCTION
0077-D
UNISEX
TOILET
0063D
CHECK IN
0063A
UNDER
UNDER CONSTRUCTION
CONSTRUCTION
OFFICE
0079-K FC
OFFICE
0079-M
DELTA
CLINIC
NURSES
OFFICE
0079-B
STORAGE
0063G
CORRIDOR
0063INFUSION CLINIC
ONCOLOGY CLINIC
OFFICE
0077Q
OFFICE WORK
RM
0077-K
ANTE
RM
0077-G EXAM
0063F
UNISEX
TOILET
0063E
STAFF
TOILET
0062-A
EMS
STORAGE
WAITING
NURSING
EXAM
RM
SOCIAL WORKER
OFFICE
DAV
OFFICE
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
UNDER
UNDER
CONSTRUCTION
0055-A
CONSTRUCTION
0055-B
EXAM
0063C
CORRIDOR
CB-10BCORRIDOR
CB-9
ONCOLOGY
OFFICE
CORRIDOR
CB-8
UNDER
CORRIDOR
CB-10
UNDER
CONSTRUCTION
0055-C
CONSTRUCTION
CB-10A
UNDER
CONSTRUCTION
0031-A
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
CB-5
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
0031B
UNDER
CONSTRUCTION
EMS
B11 CHECK IN
0079-K
PULMONARY/
RESPIRATORY
CARE
WAITING
0079-A
VAULT
0077-A1
UNDER
CONSTRUCTION
0077-B
VAULT
0077-A
PHARMACY
UNDER
CONSTRUCTION
0077-C
PHARMACY
WAITING
CB-11A
CORRIDOR
CB-11A
OPHTHALMOLOGY
EXAM
B09
CORRIDOR
CB-12
UP
STAIRS
B10
DN
LOUNGE
MALE LOCKER
80-B
COMMON
CLOSET
TB-1
FEMALE
LOCKER
80-C
FEMALE TOILET
0076-B
MALE
TOILET
0076-A DRESSING
RM
ELECTRICAL
CLOSET
EB-1
SPD
STORAGE
0074J
STORAGE
DECONTAMINATION
B081
CART WASH
0081-C
UTILITY
RM
0080-C
OFFICE
0068-B
OFFICE
0074-A
SUPPLY
RM
0074-B
EXAM RM
LAU 5
0074-C
CORRIDOR
CB-15
WORK
RM
0074-H
WORK
RM
0074-G
WAITING
0074-I
CORRIDOR
CB-11A
OUT-PATIENT
DROP/
PRESCRIPTION
OFFICE
0077-P FISCAL
CASHIER
RESPIRATORY
CARE
OFFICE
OFFICE
WAITING RM
ONCOLOGY
OFFICE
STARBUCKS
HAC
FEMALE
TOILET
0030 UNDER
CONSTRUCTION
CB-6
UNDER
CONSTRUCTION
0032B
UNDER
CONSTRUCTION
UNDER
CONSTRUCTION
WOTKERS
COMPENSATION
PROGRAM
OFFICE
CANTEEN
STORAGE
0053-A
CART
STORAGE
0054A UNISEX
TOILET
UNDER
CONSTRUCTION
STAIR-6
S-206
MALE
TOILET
UNDER
CONSTRUCTION
CORRIDOR
CB-11A TELECOM
CLOSET
TB-2
EB-2
INFORMATION
OFFICE
ER
STORAGE
0027-A
FEC
CORRIDOR
CB-11A
EXAM RM
LAU 4
0074-D
EXAM RM
LAU 3
0074-E
EXAM RM
LAU 2
0074-F
0068-G
EXAM RM
LAU 1
0067 ELEVATOR ELEVATOR
NURSE
MGR
ASSISSTANT
OFFICE
ELEVATOR
MACHINE RM
STAFF
TOILET
TRIAGE
RM-2
BREAK RM
LOCKER
0026-A
STAFF
TOILET
0026-B
0028A WAITING
TRIAGE
RM-1
BAY-1
BAY-2
BAY-3
CORRIDOR STORAGE
0028-A
SPD
FC
STORAGE /
SUPPLY
0068-A DUMBWAITER BREAK RM
0024A
CORRIDOR CORRIDOR
CB-3
BAY 4
ISOLATION RM
STERILIZERS
FC
OFFICE
0068-C
NURSE MGR
OFFICE
HSKP
CLEAN UTILITY
0007-A
TOILET-1
0009-B
VESTIBULE
0009-A
ANTE
RM
ER CHECK IN
0006 NURSE STATION
AERATOR
CLEAN RM
0068-D ELEVATOR
MECH RM
0068-F
MECH
EMERGENCY RM
WAITING
EMERGENCY
GENERATOR
EB-2
COMPRESSOR
RM
0068-H
CORRIDOR
CB-1
DRY
UTILITY
PATIENT
SHOWER
TOILET-2
NOURISH
COUNTER
CORRIDOR
CB-2
BAY-4
ISOLATION
RM
0016A
BAY-6
MECH
MER-1
MECH /
ELECTRICAL
EB-1
MALE
TOILET
B0004
FEMALE
TOILET
DN HAC
MB-3 STAIR
S005
POLICE / SECURITY
RM
0002 EMERGENCY
ENTRANCE
BAY-10 ACUTE
RM
BAY-9
BAY-8
SUPPLY
TOILET 3
0011-A
BAY-7
OBSERVATION RM
CORRIDOR
CB-11A
OUTPATIENT
ENTRANCE
0028B
C O
R R
ID
O
R
U N
D
ER
C O
N
ST
R U
C
TI
O N
A
U N
D
ER
C O
N
ST
R U
C
TI
O N
-A
F E
S E
S E
S E
C
S E
S E
DH
E
DH
E
S E
C
S E
E S
E
C
S E
C
S E
C
E
S E
C
E
S E
C
E
E
E
E
E
E
S E
C S
E
C S E
C S E
C
H E
F E
F E
E
E
S E
S E
S E
S E
E
S E
C S
E
C
F E
E
C
E
S E
C
E
S E
E
E
E
S E
S E
CS
E
C
S E
C
S E
C
E
E S E
E
S E
S E
S E
C S
E
C
FEC
E
S E
C
S E
C
S E
C
S E
C
S E
C
DH
E
DH
E
S E
E
S E
S E
E
C
E
E
S E
S E
C
E
S E
C
F E
E
S E
S
ES
E
C
S E
C
E
S E
E
E
E
S E
S E
S E
S E
S E
E
DH
E
DH
E
S E
S E
C
E E
C
E
TS
E
WF
E
DH
E
DH
E
S E
C
ES
E
S E
S E
F E
FACP
N
AC
FATC
FATC
S
EH E H E
S E
E
E
E
E
E
S E
E
S E
E S
E
F E
S E
S E
EE
E
N
AC
NAC
S E
S E
S E
S E
S E
S E
S E
S E
S E
E
E
E
E
E
E S
E
S E
E
E
E
E
E
E
S E
C
S E
S E
E
E
FAA
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA102)
M
ATCHLIN
E (FA101)
MATCHLINE
MATCHLINE
MATCHLINE
MATCHLINE
U N
D
ER
C O
N
ST
R U
C
TI
O N
-B
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
C B-
A
M
EC
H U
N D
ER
C
O N
ST
R
U C
TI
O
N
-A
FE
C
U N
D
ER
C O
N
ST
R U
C
TI
O N
EB
-5
D O
G W
O O
D C
LI
N
IC
U N
D
ER
C O
N
ST
R U
C
TI
O N
C B-
U N
D
ER
C O
N
ST
R U
C
TI
O N
C B-
B
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
U N
D
ER
U N
D
ER
C O
N
ST
R U
C
TI
O N
C O
N
ST
R U
C
TI
O N
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
U N
D
ER
C O
N
ST
R U
C
TI
O N
M
AT
CH
LI
N E
M
AT
CH
LI
N E
M
AT
CH
LI
N E
M
AT
CH
LI
N E
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA102
BUILDING 1 BASEMENT
SCALE:
BUILDING 1 BASEMENT FLOOR PLAN - EXISTING
ST
O
R
AG
E
H O
U
SE
KE
EP
IN
G
OFFICE
OFFICE
OFFICE
TO BUILDING 03
OFFICE
HAS
BREAK RM
FILE RM
IT
CHIEF OF URGENT
CARE OFFICE
MALE TOILET
A116
ELECTRICAL
ELECTRICAL
CONFERENCE RM
CHIEF NURSE
GERIATRICS
AND EXTENDED
CARE
CHIEF NURSE
MEDICINE
NURSE
RECRUITER
OFFICE
DEPUTY
ASSOCIATE
DIR PATIENT
CARE SVC
SEC / RECPT
CHIEF NURSE
SURGERY
OFFICE
BREAK RM
CONFERENCE RM
145 MENS TOILET
143A
P AND R SUPER
LEAD HR SPLT
OPEN OFFICES
STORAGE
141A
STORAGE
137-B
CHIEF OF
CHAPLAIN SVC
FEMALE TOILET
EXAM RM 2
115-L
OPEN OFFICES PATIENT CARE
SERVICES STAFF
TBI CASE
MGR OFFICE
115-K
CHAPEL
EXAM RM 4
115-J
CHAPLAIN OFFICE
137-A
FEMALE
TOILET
135 TBI NURSE
PRACTITIONER
EXAM
115-M
STORAGE
137-C
MALE
TOILET
CAROLINA EXECUTIVE
CONFERENCE RM
ADVOCATE
OFFICE
ADVOCATE
OFFICE
LOBBY
OFFICE
VACANT
128 OFFICE
127 ELECTRICAL
128-A
PGM ADVOCATE
OFFICE
115-N
MECH
CORRIDOR
C1AN
ELECTRICAL
FEC
CORRIDOR
C1AS
ELECTRICAL
E133 TOILET
132-A
IRM CLOSET
190-B1
TELEPHONE
CLOSET
190-B CORRIDOR
ELEVATOR ELEVATOR
MECH
175A
VACANT
CHAPLAIN
OFFICE
177 HR ASST (P AND R)
OFFICE
CONFERENCE
RM
180 NURSING SVC
ADMIN OFFICE
181-A
SECRETARY
OFFICE
STAIR
175 OFFICE
UNISEX
TOILET
A117
STAIR
TOILET
190-A
ASSOCIATE
DIR OFFICE
(OPERATION)
190 ELEVATOR
ELEVATOR
COMMUNICATION OFFICE
OFFICE
DECEDENT
AFFAIRS
HEALTH
BENEFITS AND
TRAVEL OFFICE
ASSOCIATE DIR OF
NURSING
181-B
CORRIDOR
ADMIN OFFICE
HEALTH SYSTEMS
SPECIALIST FOR
OPERATION
STORAGE
102-A
STAIR
FEC ELEVATOR
TELECOM
CLOSET
OFFICE
112-A
STAIR
(OPERATION) LEAF
COORDR OFFICE
VACANT
PIV OFFICE
102 EEO OFFICE
106-A
CHIEF OFFICE
(CHIEF OF RM 184)
185 PIV OFFICE
OFFICE
112-B
VETERANS CANTEEN
SVC CONFESSION
OFFICE
EEO MGR OFFICE
STAFF
TOILET
112-D
EEO OFFICE
106 OFFICE
112-C
OFFICE
EMPLOYEE
AND LABOR
RELATION
SPECIALIST
112-E
E
E
E
E
E
E
E
E
E
E
S E
E E
E
C
E
E
S E
FATC
E
F E
E
E
E
E
E
D
E
E
NAC
E
E E
S E
S E
E E
E E
E
E
E
E
DH
E
S E
C
C
E
E
E
E
S E
C
S E
C
F E
E
S E
C
S E
C
S E
FACP
S E
E
D
E
S E
C S
E
C
C
E S
E
C S E
S E
S E
C
E
F E
S E
S E
DH
E
DH
E
S E S E S
E
C S
E
C
FA
C
P
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA104)
M
ATCHLIN
E (FA103)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA103
BUILDING 1 FIRST FLOOR
SCALE:
BUILDING 1 FIRST FLOOR PLAN - EXISTING
C
R R
ID
O
R C
1- 2B
ST
O
R
AG
E
C O
R R
ID
O
R
LO
C
KE
R
IMAGING SVC MGR OFFICE
1013-B
IMAGING SVC
SUPERVISOR
1013-A
EXAM RM 2
115-L
TBI CASE
MGR OFFICE
115-K
EXAM RM 4
115-J EXAM RM 5
115-I
PM AND RS
SERVICE
CHIEF
OFFICE
115-H
LOUVER WINDOW STORAGE
1043-C
HISTOLOGY
ENGG
STORAGE
CORRIDOR
EXAM RM 7
115-G
WORK RM
1046B
OFFICE
1046-A
LAB
1043-A
LAB
1043-B
WORK RM
BREAK RM
CONTRACT
SUPPLIES
1041A
FC
CHIEF
PATHOLOGIST
OFFICE
1040A
CORRIDOR
TBI NURSE
PRACTITIONER
EXAM
115-M
EXAM RM 8
115-F
MECH
MER 21
MICROBIOLOGY
HEMATOLOGY
LAB
PATHOLOGY
OFFICE
OFFICE
127 ELECTRICAL
128-A
PGM ADVOCATE
OFFICE
115-N RECEPTIONIST
115-C
STORAGE
115-B
DIGITAL IMAGING
OCT OCULAR
PHOTOGRAPHIC
STORAGE
115-E
EXAM
115-D
LOUVER WINDOW
BLOOD BANK
UNISEX
BARIATRIC
TOILET
1052A
WOMENS
TOILET
1053A
CONFERENCE
RM
TBI CLINIC 115-A
PRIVACY
OFFICER
MALE TOILET
FEMALE TOILET
FEC
ELECTRICAL
LAB
WAITING/RECEPTION AREA
CORRIDOR
C1-10
BAY-4
1054D
BAY-5
1054E
BAY-6
1054F
OFFICE
MENS
TOILET
1050A
CORRIDOR
MENS
TOILET
1051A
CORRIDOR
C1-11
PHLEBOTOMY AREA
CORRIDOR
C1-13
PHLEBOTOMY
STORAGE
BAY-1
1054A
BAY-2
1054B
BAY-3
1054C
OFFICE
MALE
TOILET
1035-A
MALE
LOCKER
FEMALE
TOILET
1036-A
FEMALE
LOCKER
CORRIDOR
C1-1
TELEPHONE
CLOSET
TL-2
UP DN
OFFICE
DECEDENT
AFFAIRS
HEALTH
BENEFITS AND
TRAVEL OFFICE
TBI CLINIC WAITING
114 OFFICE
OFFICE
112-A
STAIR
HR OFFICE
112-K
RECEPTION OFFICE
HOUSEKEEPING
DRESSING
RM
1006-B
EXAM
TOILET
1006-A
DRESSING
RM
1006-C
OFFICE
1015A
IMAGING
WAITING
T-1-1
CHECK IN
ELEVATOR ELEVATOR
ELECTRICAL
E-1-1 EMS STORAGE
ELECTRICAL
E1-2
OFFICE
112-B
BIO-HAZARD
INFECTIOUS
WASTE
1011-B DRESSING
RM
1011-B1
EXAM
DRESSING
RM
1010-A
EXAM
CORRIDOR
TOILET
1010B
FC
CHIEF OFFICE
RADIOLOGY
1021-E
PATIENT REP
OFFICE
PATIENT CLOTHING
AND EFFECTS
RELEASE OF INFO OFFICE
OFFICE NUCLEAR
MEDICINE SECY
1021-F
X-RAY RM
DRESSING
RM
1007-B
DRESSING
RM
1007-A
UNISEX
TOILET
PATIENT PREP
1024A
WAITING
CONTROL
1024C
EXAM RM / MRI
MACH
STAFF
TOILET
112-D
OFFICE
112-C
CORRIDOR
1310 CONFERENCE RM
112-J
STORAGE
112-I
CORRIDOR
STORAGE
112-H ULTRASOUND
1012UNISEX TOILET
1011-A
WORK RM
1015-C
OFFICE
EMPLOYEE
AND LABOR
RELATION
SPECIALIST
112-E
FILE RM
112-F
EMPLOYEE
ANDLABOR
RELATIONS
SPECIALIST
112-G
OFFICE CORRIDOR
ULTRASOUND
EXAM RM
1012-A
ULTRASOUND
EXAM RM
1012-B
STORAGE
1015-B1
READING
RM
1015-A IMAGING
STORAGE
1017 CORRIDOR CT SCAN
BREAK RM
DRESSING
RM
1024B
CT SCAN
CONTROL
1022A
SEALED OFFICE
1015-B
VIEWING RM
1015-C
STAFF
RADIOLOGY
STAFF
RADIOLOGY
UNISEX
TOILET
SUPPLY
1029C
CT SCAN
WAITING
1022B
MECH
EQUIP
HOT LAB
1021-B
IV RM
1021-C
DRESSING
RM
1029A
MAMMOGRAPHY SUITE
SECY
RADIOLOGY SVC
CT
OFFICE
1014A
CT SCAN
1014B
CONTROL
RM
1014C
CT EQUIP RM
1014D CLOSET
1014E
DR IN WALL
CLOTHS
STORAGE
1019 CT STORAGE
UNISEX
TOILET
1029B
STAIR - 9
4-DUP
DN
TECH RM
1021-A NUCLEAR
MEDICINE
IMAGING RM
CONTROL
BULK HEAD
STORAGE
SUPPLY
1022-C
CORRIDOR
NUCLEAR
MEDICINE
IMAGING RM
1021A
STORAGE
1021-C1
NUCLEAR MEDICINE
WAITING
1021K
STAIR
S-106
LAB SECY
OFFICE
SUPPLY
IM
AGIN
G R M
S E
C
F E
E
E
S E
C
E
E
E
F E
S E S E
C DH
E
DH
E
S E
FA
C
P
S E
C
S E
C
S E E
E
S E
C S
E
C S
E
C
FEC
S EFA
C
P
S E
S E
S E
S E
S E
S E
C E
S E
S
EE
E
F E
E
S E
C S
E
C S
E
C
S E
C
S E
CS
E
C
S E
C S
E
C S
E
C
S E
C
E S
E
S E
E
S E E
S E S E
E
E
FEC
S E
C
S E
C
S E
C
S E
C
S E
C
S E
C
E
S E
C
E
S E S E
C
E
C
E
DH
E
DH
E
S E
C S
E
C
NAC
S E S
E
C
S E
S E
C
S E
C
DH
EDH
E
S E
DH
EDH
E
S E C
E
E E
E E
C
E
S E
S E
C
E
DH
E
DH
E
E
F E
E
S E
S E
C
E S
E
C
S E
C
S E
S E
S E
E
S E
C
S E
C
F E
TS
E
WF
E
S E
E
E
E
S E
S E
C
S E
C
S E
E
TS
E
WF
E
S E
S E
N
AC
S E
S E
FSC
U
S E
S E
C
FEC
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA104)
M
ATCHLIN
E (FA103)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA104
BUILDING 1 FIRST FLOOR
SCALE:
BUILDING 1 FIRST FLOOR PLAN - EXISTING
OFFICE
OFFICE
OFFICE
UNDER CONSTRUCTION
OFFICE
OFFICE
OFFICE
OFFICE
264 CORRIDOR
C2AE
OFFICE
OFFICE
263 OFFICE
PATIENT RM
ISOLATION
PATIENT
TOILET
286A
OFFICE
OFFICE
OFFICE
FC
OFFICE
OFFICE
ELECTRICAL
260 STAIR
ELEVATOR
CLASSROOM
STORAGE
ELEVATOR
MECH
STORAGE
SOILED
UTILITY
MEDICATION RM
STAIR
PATIENT RM
EQUIPMENT
STORAGE
CLEAN
UTILITY
PATIENT
TOILET
283A
CORRIDOR
C2A
STAFF
BREAK
TOILET
257A
TOILET
WAITING
RM
TOILET
255A
NURSE STATION
NOURISHMENT
MEDICATION
RM
NURSE WORK RM
PATIENT
TOILET
248A
PATIENT
TOILET
252A
PATIENT RM
PATIENT RM
248 PATIENT
TOILET
237A
PATIENT RM
PATIENT
TOILET
251A PATIENT
TOILET
236A
PATIENT RM
PATIENT
TOILET
250A
PATIENT
TOILET
249A
PATIENT RM
PATIENT RM
PATIENT
TOILET
235A
PATIENT RM
ISOLATION
PATIENT RM
ANTE RM
236B
CORRIDOR
2AC1
PATIENT
TOILET
238A
HOUSEKEEPING
ELECTRICAL
PATIENT RM
PATIENT
TOILET
6'-97
PATIENT RM
PATIENT
TOILET
242A
PATIENT RM
STORAGE
PATIENT
TOILET
241A
PUBLIC
TOILET
PATIENT RM
238 PATIENT
TOILET
233A
PATIENT
TOILET
234A
CORRIDOR
2BC4
PATIENT RM
PATIENT RM
FEC
TELECOM
ELECTRICAL
PATIENT
RM
PATIENT
TOILET
231A
PATIENT
TOILET
230A
PATIENT
RM
TELEMETRY
NURSE
STATION
PUBLIC
TOILET
227A
WAITING
SOILED
UTILITY
CLEAN
UTILITY
NOURISHMENT
MED RM
CORRIDOR
TELECOM
291 MECH
ELEVATOR
STORAGE
MECH
STAIR
ELEVATOR
ELEVATOR
NOURISHMENT
FOOD NUTRITION
201-A
PATIENT RM
BARIATRIC
CORRIDOR
2BC3
PATIENT RM
CORRIDOR
C2EE
PATIENT
TOILET
285A
PATIENT
TOILET
288A
FOOD NUTRITION
DIETICIANS
FOOD
PATIENT
TOILET
287A
FOOD NUTRITION
NUTRITION
ANTE RM
286B
PATIENT RM
TO
B
U
IL
D
IN
G
E
E
E F E
E
E
S E
FATC
S E
E
E
E
C
E
C
E
E
E
S E
E E
E
C
E
E S
E S E
C
S E
C
S E
C
F E
S E
DH
E
DH
E
E E
E
E S
E
S E
E
FATC
N
AC
E
NAC
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA106)
M
ATCHLIN
E (FA105)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA105
BUILDING 1 SECOND FLOOR
SCALE:
BUILDING 1 SECOND FLOOR PLAN - EXISTING
PATIENT RM
PATIENT RM
217B
CORRIDOR
PATIENT
TOILET
219A
PATIENT
TOILET
218A
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT
TOILET
217A
CORRIDOR
ANTE RM
PATIENT RM
PATIENT RM
TOILET
2310-A
WAITING
HALL
MALE
TOILET
FAMILY
CONSULT
FEMALE
TOILET
PATIENT
RM
PATIENT RM
PATIENT RM
PATIENT
TOILET
216A PATIENT RM
NURSE
STATION
RESP
WORK RM
CONFERENCE
RM
SOILED
UTILITY
CORRIDOR
C2.14
OFFICE
OFFICE
RECEPTION
ELECTRICAL
UNISEX
TOILET
DN
STAIR
#7
S.207
STORAGE
PATIENT
TOILET
215A
NOURISHMENT
MED RM
HAC
ELECTRICAL
ELECTRICAL
PATIENT RM
NUTRITION
TO D WING
PATIENT
TOILET
2301-A
PATIENT RM
PATIENT RM
2301-A ANTE
RM
LINEN
ICU
WAITING
UNISEX
TOILET
2321-A
CORRIDOR
C2.11
HSA
PHYSICIAN
WORK
2051 ANESTHESIA
WORK RM
STORAGE
CORRIDOR
C2.12
STORAGE
STAIR-6
S-206
PRE-OP
PRE-OP
PRE-OP
PRE-OP
PRE-OP
CORRIDOR
C2.1 ELECTRICAL
MECH
PATIENT RM
STAIR
STORAGE
SOILED
UTILITY
TOILET
222-A
SCRUB
DATA
CLOSET
T2.1
FC TELEPHONE
CLOSET
T2-2
CORRIDOR
C2.8
CORRIDOR
C2.13
UP DN
STORAGE
PATIENT
RM
TOILET
217-A
TOILET
216-A
PATIENT RM
CORRIDOR
MECH
CORRIDOR
C2.2
MALE
LOCKER
EQUIP
OR-4
ELEVATOR
P-5
ELECTRICAL
F2-1
ELEVATOR
P-6
STORAGE
HAC
PHASE
NURSE
MGR
OR-5
CO-ORDINATOR
OFFICE
FEMALE
LOCKER
PHASE
TOILET
220-A
INSTRUMENT
PROC.
DUMB
WAITER
CLEAN
CORE
SCRUB
SUB STERILE
CORRIDOR
C2.6
HAC
MED
RM
CORRIDOR
C2.7 STAFF
TOILET
CORRIDOR
C2.9
SOILED
UTILITY
NOURISHMENT
PACU
CLEAN
UTILITY
UNISEX
TOILET
NURSE
STATION
PHASE 2
PHASE
CONFERENCE
RM
PATIENT
RM
TOILET
219-A
BREAK
RM
2008B
SUB
STERILE
CORRIDOR
C2.3
OR-1
OR-2
OR-3
STORAGE
STORAGE
PACU
NURSE
STATION
PACU
FAMILY
RM
PATIENT RM
MECH
MER.3
CORRIDOR
C2.5
SCRUB
SUB STERILE
CORRIDOR
C2.4
SCRUB
2020 PACU
PACU
PACU
ISOLATION
PACU
DICTATION
UP
STAIR-5
S-205
STORAGE
C O
R R
ID
O
R
E
E S
E
S E
E
S E
E S E
S E
S E
S E
C
S E
C
F E
S E
FEC
S E S E
DH
E
DH
E
C
E
C
E
E
FATC
N
AC
E
E
C
E
S E
C S
E
C
E
E
C
E
C
E
C
E
E
E
C
E
C
E
S E
F E
E
E
C
E
C
E
S E
C C
E C
E
C
E
C
E
F E
E E E
E
C
E
C
E
E
C
E
C
E
C
E
C
E
C
E
E
E
E
S E
RTS
RTS
RTS
RTS RTS
RTS
RTS
RTS
C
E
C
E
C
E
E
E
E
RTS
C
E
F E
TS
E
TS
E
TS
E
WF
E
WF
E
C
E
C
E
C
E
C
E
C
E
C
E
C
E
E
E
EE
E
E
E
F E
S E
CS
E
C S
E
C
S E
C
S E
C
E
E
FEC
FEC
S E
DH
E
DH
E
RTS
RTS
RTS
RTS
E
E
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA106)
M
ATCHLIN
E (FA105)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA106
BUILDING 1 SECOND FLOOR
SCALE:
BUILDING 1 SECOND FLOOR PLAN - EXISTING
KITCHEN
NOURISH
392-A
PATIENT RM
PATIENT
TOILET
374-A
PATIENT RM
374 PATIENT
TOILET
376-A
PATIENT RM
TOILET
372-A
PATIENT RM
PATIENT RM
PATIENT
TOILET
368-A
CORRIDOR
C300-C
PATIENT RM
PATIENT RM
367 PATIENT
TOILET
367-A
DICTATION
PATIENT RM
TOILET
363-A
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT
TOILET
359-A
PATIENT RM
PATIENT RM
PATIENT RM
360 PATIENT
TOILET
340-A
PATIENT RM
PATIENT RM
342 PATIENT RM
CORRIDOR
C300-B
PATIENT
TOILET
342-A
PATIENT RM
PATIENT TOILET
338-A
PATIENT RM
MED RM
NURSES STATION
MALE / FEMALE
TOILET
ELECTRICAL
KITCHEN
NOURISH
CORRIDOR
C300-A
CLEAN LINEN
SPD STORAGE
ANTE RM
367-B
PATIENT RM
ANTE RM
370-B
ELEVATOR LOBBY
FC STAIR
PATIENT
TOILET
380A
PATIENT
TOILET
381-A
SOILED
LINEN
HOPPER FC HOUSEKEEPING
CORRIDOR
BATH RM
337 NURSE MGR
FEC
ELECTRICAL
UNISEX TOILET
335-A
PATIENT
TOILET
370-A
ELEVATOR ELEVATOR PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT
TOILET
384-A
TELECOM
CLOSET
STAIR
WARD
STORAGE
CORRIDOR
C300-D
SHOWER
ELECTRICAL
378 OFFICE
392-C
DAY RM
PATIENT RM
CONFERENCE
RM
392-B
PA
TI
EN
T
TO
IL
ET
1- A
C O
U N
TE
R
D
ES
K
S E
S E
C
E
S E
S E
FEC
E
FACP
F E
S E
S E E
E
S E
S E
C
E
S E
S E S E
S E
C
E
S E
C
S E
S E F E
E DH
E
DH
E
S E
S E
E
S E
C
E
F E
S E
E
S ES
E
C
E
E
S E
S E
S E
C
S E
C
S E
FACP
FATC
NAC
E
S E
C
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA108)
M
ATCHLIN
E (FA107)
FIRE ALARM LEGEND
NFPA 170 VA DESCRIPTION
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
NOTIFICATION CIRCUIT POWER
BOOSTER, EXTENDER PANEL
N = UNIT NUMBER
RELEASING SERVICE CONTROL UNIT
TYPE - WET CHEMICAL
ELEVATOR STATUS/RECALL
FIRE ALARM ANNUNCIATOR
FIRE SUPPRESSION CONTROL UNIT
ADDRESSABLE OUTPUT MODULE
ADDRESSABLE INPUT MODULE
ADDRESSABLE DUAL INPUT MODULE
MANUAL FIRE ALARM BOX
WET CHEMICAL
DOOR HOLD OPEN
POST INDICATOR VALVE
FLOW SWITCH
TAMPER SWITCH
SMOKE DETECTOR
IN DUCT SMOKE DETECTOR *
DUCT SMOKE DETECTOR *
DUCT INDICATOR
HEAT DETECTOR
MANUAL PULL STATION
HALON PULL STATION
HORN STROBE - CEILING
HORN STROBE - WALL
SPEAKER STROBE - CEILING
SPEAKER STROBE - WALL
SPEAKER - CEILING
SPEAKER - WALL
STROBE - CEILING
STROBE - WALL
GONG
ADDRESSABLE CONTROL RELAY (AT
ACCESS CONTROL POWER SUPPLY
FOR MAGLOCK DOOR RELEASE)
FACP
FATC
NACn
RSFACU
WC
ESR
FAA
FSCU
AOM
AIM
AIM
WC
DH
PIV
WF
E
TS
S
S ID
S
RTS
H
F
HL
C
C
S C
S
E
CD
F G
CR
AC
NEW
EXISTING
N
E
DEVICE ABBREVIATIONS
DEMOLISHD
REPLACER
C
E CEILING
CANDELA
RATING
EXISTING
NOTIFICATION SYMBOL
LEGEND
*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR
AHU SHUTDOWN
ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE
ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE
DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR
ADJACENT TO THE CONTROLLERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA107
BUILDING 1 THIRD FLOOR
8' 0 4' 8' 16'
SCALE 1/8" = 1'-0"
PLAN
NORTH
SCALE:
BUILDING 1 THIRD FLOOR PLAN - EXISTING
392-A
PATIENT RM
TOILET
326-A
PATIENT
TOILET
340-A
PATIENT RM
340 PATIENT RM
PATIENT RM
PATIENT RM
342 PATIENT RM
TOILET
324-A
PATIENT RM
PATIENT
TOILET
342-A
PATIENT RM
PATIENT TOILET
338-A
PATIENT RM
PATIENT RM
HOUSEKEEPING
CORRIDOR
BATH RM
337 NURSE MGR
GERIATRIC
SVC OFFICE
334-A
PRACTITIONER
OFFICE
NURSE MGR
NURSE LOUNGE
TOILET
331-A PATIENT RM
FEC
ELECTRICAL
UNISEX TOILET
335-A
CORRIDOR
HOUSEKEEPING
TELECOM
CLOSET
STAIR
WARD
STORAGE
HOUSEKEEPING
LOCKERS
STAIR
301 ELEVATOR
TOILET
309-A
NOURISHMENT KITCHEN
ANTE RM
331-B
STAFF TOILET
330-A
SOILED UTILITY
CLEAN LINEN
311-C NURSES STATION
311B
CORRIDOR
C300-A
(MEDICAL SURGICAL WARD)
VESTIBULE
330-B
ELECTRICAL
TOILET
328-A
TOILET
322-A
PATIENT RM
STORAGE
MED RM
311-A
STAIR
ELEVATOR STORAGE
PATIENT RM
TELE MEDICINE
311-A
PATIENT RM
FC FC
WINDOW CAN'T SEE IN RM
OFFICE
392-C
MEDICINE ADMIN
OFFICER MED SVC
SVC
ELEVATOR TOILET
319-A
PATIENT RM
PATIENT RM
DAY RM
MEDICINE TELEHEALTH
LEAD CARE CO-ORDR
OFFICE
302-A
CORRIDOR
CHIEF MED SVC
304-B
SECY MED SVC
304-A
TOILET
313-A
PATIENT RM
CORRIDOR
C300-B
MED SVC OFFICE
303-A
PGM SPECIALIST
MED SVC
CONFERENCE
RM
392-B
PATIENT RM
TOILET
317-A
TO BLDG 3
TOILET
315-A
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
328 CORRIDOR
C300-C PATIENT RM
C O
U N
TE
R
D
ES
K
E
E DH
E
DH
E
S E
S E
E
S E
C
E
F E
S E
E
S ES
E
C
E
E
S E
S E
S E
C
S E
C
S E
FACP
FATC
NAC
E
S E
C
E
S E
C
S E
C
S E
C
F E
S E
E
DH
E
DH
E
S E
S E
C
S E
C S
E
C
S E
C
S E
C
S E
C
S E
C
S E
C
E
E
S E
S EFA
C
P
F E
F E
S E
E
E
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA108)
M
ATCHLIN
E (FA107)
FIRE ALARM LEGEND
NFPA 170 VA DESCRIPTION
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
NOTIFICATION CIRCUIT POWER
BOOSTER, EXTENDER PANEL
N = UNIT NUMBER
RELEASING SERVICE CONTROL UNIT
TYPE - WET CHEMICAL
ELEVATOR STATUS/RECALL
FIRE ALARM ANNUNCIATOR
FIRE SUPPRESSION CONTROL UNIT
ADDRESSABLE OUTPUT MODULE
ADDRESSABLE INPUT MODULE
ADDRESSABLE DUAL INPUT MODULE
MANUAL FIRE ALARM BOX
WET CHEMICAL
DOOR HOLD OPEN
POST INDICATOR VALVE
FLOW SWITCH
TAMPER SWITCH
SMOKE DETECTOR
IN DUCT SMOKE DETECTOR *
DUCT SMOKE DETECTOR *
DUCT INDICATOR
HEAT DETECTOR
MANUAL PULL STATION
HALON PULL STATION
HORN STROBE - CEILING
HORN STROBE - WALL
SPEAKER STROBE - CEILING
SPEAKER STROBE - WALL
SPEAKER - CEILING
SPEAKER - WALL
STROBE - CEILING
STROBE - WALL
GONG
ADDRESSABLE CONTROL RELAY (AT
ACCESS CONTROL POWER SUPPLY
FOR MAGLOCK DOOR RELEASE)
FACP
FATC
NACn
RSFACU
WC
ESR
FAA
FSCU
AOM
AIM
AIM
WC
DH
PIV
WF
E
TS
S
S ID
S
RTS
H
F
HL
C
C
S C
S
E
CD
F G
CR
AC
NEW
EXISTING
N
E
DEVICE ABBREVIATIONS
DEMOLISHD
REPLACER
C
E CEILING
CANDELA
RATING
EXISTING
NOTIFICATION SYMBOL
LEGEND
*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR
AHU SHUTDOWN
ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE
ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE
DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR
ADJACENT TO THE CONTROLLERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA108
BUILDING 1 THIRD FLOOR
8' 0 4' 8' 16'
SCALE 1/8" = 1'-0"
PLAN
NORTH
SCALE:
BUILDING 1 THIRD FLOOR PLAN - EXISTING
PATIENT
TOILET
471-A
PATIENT RM
PATIENT RM
FC
PATIENT
TOILET
473-A
OFFICE
PATIENT RM
PATIENT
TOILET
469-A
ELECTRICAL
CLOSET
CORRIDOR
C400-D
STORAGE
OFFICE
487 CORRIDOR
OFFICE
HEAD
NURSE
OFFICE
PATIENT RM
PATIENT RM
PATIENT
TOILET
467-A
CORRIDOR
C400-C
PATIENT RM
PATIENT RM
465-A
PATIENT RM
TOILET
462-B
PATIENT
TOILET
461-A
PATIENT RM
PATIENT RM
PATIENT
TOILET
459-A
PATIENT RM
PATIENT RM
PATIENT
TOILET
457-A
FC
CABINET BELOW
CORRIDOR
C400-B
PATIENT RM
4A DAY RM
ANTE RM
462-A
NURSE
CONFERENCE RM
456 ASSISTANT
CHIEF
OFFICE
447-A
DAYROOM KITCHENETTE
CHIEF
OFFICE
PATIENT RM
MED RM
CORRIDOR
C400-3
NURSE STATION
ELECTRICAL
STAFF TOILET
NOURISHMENT
KITCHEN
CLEAN LINEN
STORAGE
ELEVATOR LOBBY
463-4
SHAFT
PATIENT RM
ELEVATOR ELEVATOR PATIENT RM
PATIENT
TOILET
478-A
PATIENT RM
PATIENT
TOILET
479-A
SOILED
UTILITY
FC HOUSEKEEPING
ELECTRICAL
CLOSET
A434
CORRIDOR
CORRIDOR FEMALE
TOILET
OFFICE
INTERIOR
DESIGN
OFFICE
488-A
TELECOM
CLOSET
PATIENT RM
SHAFT
PATIENT
TOILET
482-A
COUNSELING RM
SHAFT
FP
PATIENT RM
LOCKERS
484-B
ADMIN
OFFICE
485-A TELECOM
CLOSET
DWGS
STORAGE
DECON
STORAGE
STAIR
OFFICE
STAIR WELL
STORAGE
OFFICE
OFFICE
PATIENT RM
OFFICE
MENS
TOILET
OFFICE
E
FA
TC
N
AC
S ES
E
C
E
RTS
S E
S E
C
RTS
E
S E
S E
S E
FATC
F E
S E
S E
C
S E
C
S E
C
S E
C
S E
C S
E
C
S E
S E
S E
S E
E
RTS
E
S E
S E S E
S E
E
S E
S E
S E S
E
C
F E E
DH
E
DH
E
S E S E
S ES E
S E
S E
C
S E
C
S E
C
S E
C
E
E
E
S E
S E
E
C
E
F G
E
S E
E
E
E
E
F E
S E
C
S E
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA110)
M
ATCHLIN
E (FA109)
FIRE ALARM LEGEND
NFPA 170 VA DESCRIPTION
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
NOTIFICATION CIRCUIT POWER
BOOSTER, EXTENDER PANEL
N = UNIT NUMBER
RELEASING SERVICE CONTROL UNIT
TYPE - WET CHEMICAL
ELEVATOR STATUS/RECALL
FIRE ALARM ANNUNCIATOR
FIRE SUPPRESSION CONTROL UNIT
ADDRESSABLE OUTPUT MODULE
ADDRESSABLE INPUT MODULE
ADDRESSABLE DUAL INPUT MODULE
MANUAL FIRE ALARM BOX
WET CHEMICAL
DOOR HOLD OPEN
POST INDICATOR VALVE
FLOW SWITCH
TAMPER SWITCH
SMOKE DETECTOR
IN DUCT SMOKE DETECTOR *
DUCT SMOKE DETECTOR *
DUCT INDICATOR
HEAT DETECTOR
MANUAL PULL STATION
HALON PULL STATION
HORN STROBE - CEILING
HORN STROBE - WALL
SPEAKER STROBE - CEILING
SPEAKER STROBE - WALL
SPEAKER - CEILING
SPEAKER - WALL
STROBE - CEILING
STROBE - WALL
GONG
ADDRESSABLE CONTROL RELAY (AT
ACCESS CONTROL POWER SUPPLY
FOR MAGLOCK DOOR RELEASE)
FACP
FATC
NACn
RSFACU
WC
ESR
FAA
FSCU
AOM
AIM
AIM
WC
DH
PIV
WF
E
TS
S
S ID
S
RTS
H
F
HL
C
C
S C
S
E
CD
F G
CR
AC
NEW
EXISTING
N
E
DEVICE ABBREVIATIONS
DEMOLISHD
REPLACER
C
E CEILING
CANDELA
RATING
EXISTING
NOTIFICATION SYMBOL
LEGEND
*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR
AHU SHUTDOWN
ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE
ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE
DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR
ADJACENT TO THE CONTROLLERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA109
BUILDING 1 FOURTH FLOOR
8' 0 4' 8' 16'
SCALE 1/8" = 1'-0"
PLAN
NORTH
SCALE:
BUILDING 1 FOURTH FLOOR PLAN - EXISTING
OFFICE
487 CORRIDOR
OFFICE
BATH RM
419A
SLEEP RM 5
PHYSICIAN
OFFICE
CABINET BELOW
SLEEP RM 4
BATH RM
420A
STORAGE
417A
4A DAY RM
SLEEP RM 3
ASSISTANT
CHIEF
OFFICE
447-A
DAYROOM KITCHENETTE
CHIEF
OFFICE
BATH RM
421A
SLEEP RM 2
EMS
BATH RM
421A
CLOSET
417B
SLEEP RM 1
ELECTRICAL
CLOSET
A434
CORRIDOR
CORRIDOR
BATH RM
421A
SOILED
UTILITY
417C
STAFF
TOILET
417D
FEMALE
TOILET
OFFICE
INTERIOR
DESIGN
OFFICE
SAFETY
MGR
OFFICE
BIOMED
SUPERVISOR
OFFICE
BIOMED
WORK RM
DIRTY
RM
ELECTRICAL
TESTING/LAB
488-A
STORAGE
DATA
CLOSET
RECEPTION
TELECOM
CLOSET
COUNSELING RM
SHAFT
FP
CORRIDOR
C4BSS
SHAFT
CORRIDOR
CONTROL
LOCKERS
484-B
ADMIN
OFFICE
485-A TELECOM
CLOSET
DWGS
STORAGE
DECON
STORAGE
CORRIDOR
C4EE
STORAGE
EOC FILE RM
FM SVC
ELEVATOR
PASSENGER
MENS
TOILET
HAC
OFFICE
STAIR WELL
STORAGE
OFFICE
SHAFT FEC
STAIR
SVC
ELEVATOR
STAIR
WOMENS
TOILET
SAFETY OFFICE
STORAGE
SLEEP RM 6
BATH RM
410A VISITOR
TOILET
408A
ROOF
CLEAN
SLEEP RM 7
411 BATH RM
411A
STORAGE
408B
SLEEP RM 8
BATH RM
412A
OFFICE
OFFICE
MENS
TOILET
OFFICE
SLEEP RM 9
BATH RM
413A
CLEAN
LINEN
408C
BATH RM
414A
SLEEP RM 10
OFFICE
FA
TC
N
AC
E E
DH
E
DH
E
S E S E
S ES E
S E
S E
C
S E
C
S E
C
S E
C
E
E
E
S E
S E
E
C
E
F G
E
S E
E
E
E
E
F E
S E
C
S E
C S
E
C
S E
C
S E
C
S E
C
S E
C
S E
C
S E
C
S E
S E S E
F E
E
FACP
E
E
E
E
E
S E
C
S E
C
S E
C
S E
C
F E
E
E
E
S E
S E
E
E
S E
TS
E
WF
E
FA
TC
N
AC
E
E
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA110)
M
ATCHLIN
E (FA109)
FIRE ALARM LEGEND
NFPA 170 VA DESCRIPTION
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
NOTIFICATION CIRCUIT POWER
BOOSTER, EXTENDER PANEL
N = UNIT NUMBER
RELEASING SERVICE CONTROL UNIT
TYPE - WET CHEMICAL
ELEVATOR STATUS/RECALL
FIRE ALARM ANNUNCIATOR
FIRE SUPPRESSION CONTROL UNIT
ADDRESSABLE OUTPUT MODULE
ADDRESSABLE INPUT MODULE
ADDRESSABLE DUAL INPUT MODULE
MANUAL FIRE ALARM BOX
WET CHEMICAL
DOOR HOLD OPEN
POST INDICATOR VALVE
FLOW SWITCH
TAMPER SWITCH
SMOKE DETECTOR
IN DUCT SMOKE DETECTOR *
DUCT SMOKE DETECTOR *
DUCT INDICATOR
HEAT DETECTOR
MANUAL PULL STATION
HALON PULL STATION
HORN STROBE - CEILING
HORN STROBE - WALL
SPEAKER STROBE - CEILING
SPEAKER STROBE - WALL
SPEAKER - CEILING
SPEAKER - WALL
STROBE - CEILING
STROBE - WALL
GONG
ADDRESSABLE CONTROL RELAY (AT
ACCESS CONTROL POWER SUPPLY
FOR MAGLOCK DOOR RELEASE)
FACP
FATC
NACn
RSFACU
WC
ESR
FAA
FSCU
AOM
AIM
AIM
WC
DH
PIV
WF
E
TS
S
S ID
S
RTS
H
F
HL
C
C
S C
S
E
CD
F G
CR
AC
NEW
EXISTING
N
E
DEVICE ABBREVIATIONS
DEMOLISHD
REPLACER
C
E CEILING
CANDELA
RATING
EXISTING
NOTIFICATION SYMBOL
LEGEND
*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR
AHU SHUTDOWN
ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE
ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE
DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR
ADJACENT TO THE CONTROLLERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA110
BUILDING 1 FOURTH FLOOR
8' 0 4' 8' 16'
SCALE 1/8" = 1'-0"
PLAN
NORTH
SCALE:
BUILDING 1 FOURTH FLOOR PLAN - EXISTING
TEAM RM
OFFICE
OFFICE
OFFICE
OFFICE
ELEVATOR MIC RM
ELEVATOR
SWITCHGEAR
DN CHUTE
FECMED.CART
STORAGE
NURSE STATION
LOCK DOWN UNIT
CRASH CART
STORAGE
BED RM-20
BATH-20
567A
BATH-19
566A
BED RM-19
CORRIDOR
C5-10
BED RM-15
BED RM-18
BATH-18
565A
BATH-17
564A
BED RM-17
BATH-16
563A
BED RM-16
BATH-15
562A
DAYRM
DINING RM
(LOCK DOWN
UNIT)
TELECOM RM
544-A
STAFF
TOILET-2
CORRIDOR
C5-9
CORRIDOR
C5BS
PATIENT RM
OFFICE
OFFICE
CORRIDOR
C5BN
DN
STORAGE
OFFICE
MALE
TOILET
OFFICE
STAIR
FEMALE TOILET
S E
S E
S E
S E
S E
S E
S E
S E
S E
S E
S E
E
E
E
E
C
H E H E
H E H E
S E
ES
R
E
F E
S E
TS
E
WF
E
E
C
E
C
FATC
NAC
S E
C
E
S E
C
S E
C
S E
E
E
E
S E
S E
F E
S E
S ES E
S E S E
S E
S E
S E
E
E
S E
C
S E
C
S E
C
E
S E
F EE
C
E
S E E
E
S E
C
E
E
S E
C S E
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA112)
M
ATCHLIN
E (FA111)
FIRE ALARM LEGEND
NFPA 170 VA DESCRIPTION
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
NOTIFICATION CIRCUIT POWER
BOOSTER, EXTENDER PANEL
N = UNIT NUMBER
RELEASING SERVICE CONTROL UNIT
TYPE - WET CHEMICAL
ELEVATOR STATUS/RECALL
FIRE ALARM ANNUNCIATOR
FIRE SUPPRESSION CONTROL UNIT
ADDRESSABLE OUTPUT MODULE
ADDRESSABLE INPUT MODULE
ADDRESSABLE DUAL INPUT MODULE
MANUAL FIRE ALARM BOX
WET CHEMICAL
DOOR HOLD OPEN
POST INDICATOR VALVE
FLOW SWITCH
TAMPER SWITCH
SMOKE DETECTOR
IN DUCT SMOKE DETECTOR *
DUCT SMOKE DETECTOR *
DUCT INDICATOR
HEAT DETECTOR
MANUAL PULL STATION
HALON PULL STATION
HORN STROBE - CEILING
HORN STROBE - WALL
SPEAKER STROBE - CEILING
SPEAKER STROBE - WALL
SPEAKER - CEILING
SPEAKER - WALL
STROBE - CEILING
STROBE - WALL
GONG
ADDRESSABLE CONTROL RELAY (AT
ACCESS CONTROL POWER SUPPLY
FOR MAGLOCK DOOR RELEASE)
FACP
FATC
NACn
RSFACU
WC
ESR
FAA
FSCU
AOM
AIM
AIM
WC
DH
PIV
WF
E
TS
S
S ID
S
RTS
H
F
HL
C
C
S C
S
E
CD
F G
CR
AC
NEW
EXISTING
N
E
DEVICE ABBREVIATIONS
DEMOLISHD
REPLACER
C
E CEILING
CANDELA
RATING
EXISTING
NOTIFICATION SYMBOL
LEGEND
*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR
AHU SHUTDOWN
ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE
ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE
DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR
ADJACENT TO THE CONTROLLERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA111
BUILDING 1 FIFTH FLOOR
8' 0 4' 8' 16'
SCALE 1/8" = 1'-0"
PLAN
NORTH
SCALE:
BUILDING 1 FIFTH FLOOR PLAN - EXISTING
BED RM-3
TEAM RM
BATH-2
511A
OFFICE
BATH-1
510A
OFFICE
OFFICE
OFFICE
FECMED.CART
STORAGE
NURSE STATION
LOCK DOWN UNIT
CRASH CART
STORAGE
BED RM-20
BATH-20
567A
BATH-19
566A
BED RM-19
CORRIDOR
C5-10
BED RM-15
BED RM-18
BATH-18
565A
BATH-17
564A
BED RM-17
BATH-16
563A
BED RM-16
563 BED RM-12
BATH-11
523A
BED RM-11
BATH-15
562A
BATH-12
524A
BATH-13
525A
BED RM-13
CORRIDOR
C5-4
BED RM-9
BED RM-10
BATH-10
522A
DAYRM
DINING RM
(LOCK DOWN
UNIT)
BATH-9
521A
TELECOM RM
544-A
STAFF
TOILET-2
CORRIDOR
C5-9
CORRIDOR
C5-8
CORRIDOR
C5BS
PATIENT RM
SOILED
UTILITY
541 HAC
PATIENT
STORAGE
STORAGE
RM-2
539-B
CORRIDOR
C5-7
CORRIDOR
C5-13
NOUR
INTERVIEW RM
GROUP RM
STATION
CRASH CART
ALCOVE
CORRIDOR
C5-5
BED RM-14
BATH-14
526A
ELECTRICAL
STORAGE RM-1
NURSE STATION
OPEN UNIT
DAYRM /
DINING RM
(OPEN UNIT)
FIRE EQUIP
OFFICE
OFFICE
CORRIDOR
C5BN
DN
PATIENTSTORAGE
OFFICE
RESIDENT OFFICE
BELONGINGS
STORAGE
CORRIDOR
C5EE
ELEVATOR
ELEVATOR
STAFF
TOILET-1
501A STAFF BREAK
RM AND
STAFF
LOCKER AREA
DICTATION
HEAD NURSE
OFFICE
MED SUPPLIES
CORRIDOR
C5-2
EXAM
CHASE
EXAM RM
TOILET
517A
MALE
TOILET
OFFICE
STAIR
STAIR
FEC ELEVATOR
BED RM-1
BATH-7
516A
STAIR
BED RM-7
BED RM-6
BATH-6
515A
FEMALE TOILET
552 BED RM-2
BATH-5
514A
BED RM-5
BATH-3
512A
BED RM-4
BATH-4
513A
BED RM-8
BATH-8
520A
LA
U
N D
R Y
2B
S E
C
E
S E
C
S E
C
S E
E
E
E
S E
S E
F E
S E
S ES E
S E S E
S E
S E
S E
E
E
S E
C
S E
C
S E
C
E
S E
F EE
C
E
S E E
E
S ES
E
C
E
E
S E
C S
E
C S E
S E
E E
E
S E
S E
S E
S E
S E
S E
S E
DH
E
DH
E
E E
E
S E
C
E
E
F E
S E
C
S E
S E
C
E
E
S E
S E
C
E E
S E S E
S E S E
S E
S E
C
E
E
E
E F E
E
FATC
S E
S E
C
E
S E
S E
C
S E
S E
C
S E
S E
C
S E
S E
C
S E
S E
C
E
E
E
KR
E
E
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA112)
M
ATCHLIN
E (FA111)
FIRE ALARM LEGEND
NFPA 170 VA DESCRIPTION
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
NOTIFICATION CIRCUIT POWER
BOOSTER, EXTENDER PANEL
N = UNIT NUMBER
RELEASING SERVICE CONTROL UNIT
TYPE - WET CHEMICAL
ELEVATOR STATUS/RECALL
FIRE ALARM ANNUNCIATOR
FIRE SUPPRESSION CONTROL UNIT
ADDRESSABLE OUTPUT MODULE
ADDRESSABLE INPUT MODULE
ADDRESSABLE DUAL INPUT MODULE
MANUAL FIRE ALARM BOX
WET CHEMICAL
DOOR HOLD OPEN
POST INDICATOR VALVE
FLOW SWITCH
TAMPER SWITCH
SMOKE DETECTOR
IN DUCT SMOKE DETECTOR *
DUCT SMOKE DETECTOR *
DUCT INDICATOR
HEAT DETECTOR
MANUAL PULL STATION
HALON PULL STATION
HORN STROBE - CEILING
HORN STROBE - WALL
SPEAKER STROBE - CEILING
SPEAKER STROBE - WALL
SPEAKER - CEILING
SPEAKER - WALL
STROBE - CEILING
STROBE - WALL
GONG
ADDRESSABLE CONTROL RELAY (AT
ACCESS CONTROL POWER SUPPLY
FOR MAGLOCK DOOR RELEASE)
FACP
FATC
NACn
RSFACU
WC
ESR
FAA
FSCU
AOM
AIM
AIM
WC
DH
PIV
WF
E
TS
S
S ID
S
RTS
H
F
HL
C
C
S C
S
E
CD
F G
CR
AC
NEW
EXISTING
N
E
DEVICE ABBREVIATIONS
DEMOLISHD
REPLACER
C
E CEILING
CANDELA
RATING
EXISTING
NOTIFICATION SYMBOL
LEGEND
*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR
AHU SHUTDOWN
ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE
ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE
DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR
ADJACENT TO THE CONTROLLERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA112
BUILDING 1 FIFTH FLOOR
8' 0 4' 8' 16'
SCALE 1/8" = 1'-0"
PLAN
NORTH
SCALE:
BUILDING 1 FIFTH FLOOR PLAN - EXISTING
MECH
S E
S E
E
E
C
TS
E
WF
E
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA114)
M
ATCHLIN
E (FA113)
FIRE ALARM LEGEND
NFPA 170 VA DESCRIPTION
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
NOTIFICATION CIRCUIT POWER
BOOSTER, EXTENDER PANEL
N = UNIT NUMBER
RELEASING SERVICE CONTROL UNIT
TYPE - WET CHEMICAL
ELEVATOR STATUS/RECALL
FIRE ALARM ANNUNCIATOR
FIRE SUPPRESSION CONTROL UNIT
ADDRESSABLE OUTPUT MODULE
ADDRESSABLE INPUT MODULE
ADDRESSABLE DUAL INPUT MODULE
MANUAL FIRE ALARM BOX
WET CHEMICAL
DOOR HOLD OPEN
POST INDICATOR VALVE
FLOW SWITCH
TAMPER SWITCH
SMOKE DETECTOR
IN DUCT SMOKE DETECTOR *
DUCT SMOKE DETECTOR *
DUCT INDICATOR
HEAT DETECTOR
MANUAL PULL STATION
HALON PULL STATION
HORN STROBE - CEILING
HORN STROBE - WALL
SPEAKER STROBE - CEILING
SPEAKER STROBE - WALL
SPEAKER - CEILING
SPEAKER - WALL
STROBE - CEILING
STROBE - WALL
GONG
ADDRESSABLE CONTROL RELAY (AT
ACCESS CONTROL POWER SUPPLY
FOR MAGLOCK DOOR RELEASE)
FACP
FATC
NACn
RSFACU
WC
ESR
FAA
FSCU
AOM
AIM
AIM
WC
DH
PIV
WF
E
TS
S
S ID
S
RTS
H
F
HL
C
C
S C
S
E
CD
F G
CR
AC
NEW
EXISTING
N
E
DEVICE ABBREVIATIONS
DEMOLISHD
REPLACER
C
E CEILING
CANDELA
RATING
EXISTING
NOTIFICATION SYMBOL
LEGEND
*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR
AHU SHUTDOWN
ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE
ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE
DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR
ADJACENT TO THE CONTROLLERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA113
BUILDING 1 PENTHOUSE FLOOR
8' 0 4' 8' 16'
SCALE 1/8" = 1'-0"
PLAN
NORTH
SCALE:
BUILDING 1 PENTHOUSE FLOOR PLAN - EXISTING
STAIR
ELEVATOR MACHINE RM
UP
MECH
SWITCH GEAR
DN
MECH PENT
S E
S E
S E
S E
S E
E
E
F E
E
C
E
C
TS
E
WF
E
TS
E
WF
E
ES E
H E
H E
ESR
E
RTS
S E
M
AT
CH
LI
N E
(F A1
M
AT
CH
LI
N E
(F A1
M
ATCHLIN
E (FA114)
M
ATCHLIN
E (FA113)
FIRE ALARM LEGEND
NFPA 170 VA DESCRIPTION
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
NOTIFICATION CIRCUIT POWER
BOOSTER, EXTENDER PANEL
N = UNIT NUMBER
RELEASING SERVICE CONTROL UNIT
TYPE - WET CHEMICAL
ELEVATOR STATUS/RECALL
FIRE ALARM ANNUNCIATOR
FIRE SUPPRESSION CONTROL UNIT
ADDRESSABLE OUTPUT MODULE
ADDRESSABLE INPUT MODULE
ADDRESSABLE DUAL INPUT MODULE
MANUAL FIRE ALARM BOX
WET CHEMICAL
DOOR HOLD OPEN
POST INDICATOR VALVE
FLOW SWITCH
TAMPER SWITCH
SMOKE DETECTOR
IN DUCT SMOKE DETECTOR *
DUCT SMOKE DETECTOR *
DUCT INDICATOR
HEAT DETECTOR
MANUAL PULL STATION
HALON PULL STATION
HORN STROBE - CEILING
HORN STROBE - WALL
SPEAKER STROBE - CEILING
SPEAKER STROBE - WALL
SPEAKER - CEILING
SPEAKER - WALL
STROBE - CEILING
STROBE - WALL
GONG
ADDRESSABLE CONTROL RELAY (AT
ACCESS CONTROL POWER SUPPLY
FOR MAGLOCK DOOR RELEASE)
FACP
FATC
NACn
RSFACU
WC
ESR
FAA
FSCU
AOM
AIM
AIM
WC
DH
PIV
WF
E
TS
S
S ID
S
RTS
H
F
HL
C
C
S C
S
E
CD
F G
CR
AC
NEW
EXISTING
N
E
DEVICE ABBREVIATIONS
DEMOLISHD
REPLACER
C
E CEILING
CANDELA
RATING
EXISTING
NOTIFICATION SYMBOL
LEGEND
*INCLUDE ADDRESSABLE CONTROL RELAY AT DUCT DETECTOR FOR
AHU SHUTDOWN
ALL ACCESS CONTROL DOOR RELEASE RELAYS THAT TIE TO THE
ACCESS CONTROL AND THE FIRE ALARM INTERLOCK FOR THE
DDC/UNIT SHUTDOWN RELAYS SHALL BE LOCATED ABOVE OR
ADJACENT TO THE CONTROLLERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FAYETTEVILLE
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
REPLACE FIRE ALARM SYSTEM
565-20-201
06-29-2022
2300 RAMSEY STREET, FAYETTEVILLE, NC 28301
FAYETTEVILLE VAMCWEST POINT
ENGINEERING ARCHITECTURE
REV 0 - ISSUED FOR CONSTRUCTION 05/30/2022 CRM EXF
BLDG 01
B1.FA114
BUILDING 1 PENTHOUSE FLOOR
8' 0 4' 8' 16'
SCALE 1/8" = 1'-0"
PLAN
NORTH
SCALE:
BUILDING 1 PENTHOUSE FLOOR PLAN - EXISTING
DENTAL LAB
B79H
TREATMENT
RM
B79F
TREATMENT
RM
B79E
TREATMENT
RM
B79B
CORRIDOR
B79I
TREATMENT
RM
B79D
TREATMENT
RM
B79C CORRIDOR
B79A
CORRIDOR
B79
DENTAL SVC
MECH
B78
ELEC.
B33
TELECOM
CLOSET
B32A
HK
STOR.
B32
OFFICE
B30
RADIOLOGY
RM
B72
DENTAL X-RAY
B31
CLOSET
B29A
DOCTOR
OFFICE
B29
FEMALE
TOILET
B28 DOCTOR
OFFICE
B27
CHIEF
DENTAL
OFFICE
B26
FEC
SUPPLY
B62L
DENTAL SERVICE
BREAK
RM
B62A
EXAM
B62K
CORRIDOR
B62
EXAM
B62J
EXAM
B62I
EXAM
B54L
B54I
OFFICE
B62F
EXAM
B62E
OFFICE
B62D
EXAM
B54H
EXAM
B54G
EXAM
UP
TREATMENT
RM
B54F
STORAGE
B62C
STORAGE
B62B
EXAM
B54E
TREATMENT RM
B54M CORRIDOR
B54
OFFICE
B54D
OFFICE
B54N
CORRIDOR
CAB-1
ELECTRICAL
B61-A
RECEPTION
B63 WAITING RM
B25
STAFF
TOILET
B61
HK
B24
EMS
DENTAL RESIDENT
OFFICE
B23
TRAINING /
LOCKER RM
B22
FEC
OFFICE
54P TREATMENT
RM
54C
SUPPLY
B31A
RADIOLOGY
RM
B73
ELEVATOR ELEVATOR
CORRIDOR
CAB-2
A WING
STAIR
B35
AEGD DIR
OFFICE
B36
OCCUPATIONAL
HEALTH
OFFICE
B37
ELECTRICAL
MALE TOILET
B38
LINEN
CHUTE
B85
SOILED LINEN
B39
CLEAN LINEN
B40
CRAMER
ASSOC
CHIEF OF
PHARMACY
OFFICE
B21
LOBBY
AUDIOLOGY /
CARDIOLOGY /
GASTROENTEROLOGY
WAITING
B41
TREATMENT
B79L
EXAM
B42A
ELECTRICAL
CLOSET
B41A
CORRIDOR
B34
EXAM
B79K
NURSE
OFFICE
B42B
CARDIOLOGY
CORRIDOR
B42
OFFICE
B42K
STAIR
B43
CORRIDOR
CB-2
PHARMACY
OFFICE
B44
STORAGE
CORRIDOR
CBB-1
PVA
OFFICE
B20 RECEPTION
B19
OFFICE
B54A
VACANT
B18B
SPEECH
THERAPY
WAITING
B18
OFFICE
B18A
ASSISTANT
CHIEF EMS
OFFICE
B17
ARMS
RM
B14C
OFFICE
B16
GATE
OFFICE
B15 POLICE
OFFICE
B14
HOLDING
CELL
B14B
CHIEF OF
POLICE
B13 POLICE
DISPATCH
OFFICE
B12
EMS
B11
POLICE
ADMINISTRATION
B14-A
CORRIDOR
CCB-1
PHARMACY
OFFICE
B45
EMS…