53373036 SPECS.pdf

PDF 2 MB Posted

Attached to
SECUIRTY GUARD BOOTHS
Solicitation number
SPMYM226Q5466
Issued by

About this file

This document is a Guard Booth Specifications file that establishes requirements for designing, manufacturing, and furnishing one fully assembled and portable guard booth. The booth must meet UL 752 Level 8 bullet resistant protection standards in all wall areas from finished ceiling to finished floor height, with the roof, fascia, overhang, soffit, and floor exempt from this requirement. Level 8 protection is designed to resist five shots from a 150-grain 7.62mm rifle with full metal copper jacketed military ball (.30 caliber) at velocities between 2750-3025 ft/sec. The minimum interior plan dimensions are 6'-0" wide by 8'-0" long with an 85" ceiling height. The exterior and interior must be constructed of UL 752 Level 8 bullet resistant armor plate steel and 16-gauge galvanized steel respectively, both painted Regal White. The roof uses all-steel construction with internal framing, galvanized steel roof deck, and internal insulation rated R-19, while the floor consists of 12-gauge galvanized steel plating.

The booth must include specific features and components: a 3' x 7' personnel door with stainless steel hinges and hydraulic closer; UL 752 Level 8 bullet resistant window systems with gray tinted laminated glass on all sides; one 20" deep shelf with storage drawer and one gunport per wall; electrical systems including a 125-amp load center, four duplex outlets, LED interior lighting with emergency backup, four exterior flood lights, and a GE Model No. AJEQ12DWJ air conditioning unit with 12,000 BTU cooling and 10,600 BTU heating. All electrical equipment must be UL Solutions approved. The manufacturer must have at least five years of continuous experience fabricating similar pre-engineered, fully assembled guard booths. Design must comply with 2021 International Building Code standards, 2022 AISC structural steel specifications, and 2025 AWS welding standards. Upon award, the vendor must submit final engineered drawings requiring PSNS C/106 and C/1121 concurrence.

View the file

Other files

File Type Posted
53373037 CDRL.pdf PDF
Solicitation SPMYM226Q5466.pdf PDF
53373036 CDRL.pdf PDF
53373037 SPECS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .