Device_Schedule_TEMPLATE-v2.xlsx
XLSX spreadsheet 70 KB Posted
- Attached to
- replace chiller Federal contract opportunity
- Solicitation number
- 47PJ0018Q0029
About this file
Device Schedule - reference document
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RESPONSE_TO_QUESTIONS.pdf | ||
| Amendment_0003.pdf | ||
| Solicitation_Amendment_47PJ0018Q0029_0002.pdf | ||
| PembinaChiller-amendment_0001.pdf | ||
| GSA_Data_Normalization_for_Building_Automation_Systems.pdf | ||
| Object_Naming_Submittal_TEMPLATE-v1.xlsx | XLSX spreadsheet | |
| GSA_R8_Open_Protocol_Implementation_Guide_-_BACnet_-_v1_0_0_FINAL.pdf | ||
| solicitation29-Pembina_chiller.pdf | ||
| GSA_PBS_Telecommunications_Distribution_Design_Guide.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BACnet Device Schedule
| BACnet Device Schedule | ||||||||||||||||||||
| BAS Contractor/Vendor | GSA IT/OFM Controls | |||||||||||||||||||
| Device Object Name | Description | Manufacturer | Model | HW MAC Address | Device Type | Net type | SW Version | FW Version | Location | Controlled Equipment | MS/TP Net(s) Supported | Host Controller | IP Address | Subnet Mask | Default Gateway | UDP Port | Device Instance | Network # | BBMD | MS/TP Add |
EXAMPLE BACnet Device Schedule
| BACnet Device Schedule | ||||||||||||||||||||
| BAS Contractor/Vendor | GSA IT/OFM Controls | |||||||||||||||||||
| Device Object Name | Description | Manufacturer | Model | HW MAC Address | Device Type | Net type | SW Version | FW Version | Location | Controlled Equipment | MS/TP Net(s) Supported | Host Controller | IP Address | Subnet Mask | Default Gateway | UDP Port | Device Instance | Network # | BBMD | MS/TP Add |
| CO0576_NODE03 | AHU1 THRU 4 VAV | SIEMENS | PXC00-E96.A | 7C:38:66:42:08:F1 | B-BC | BACnet/IP | 3.15 | 3.4 | Mech A124 | VAV terminal units | 8503 | NA | 192.168.177.21 | 255.255.255.0 | 192.168.217.1 | 47808 | 850300 | 8500 | No | 0 |
| CO0576_VAV209 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:BD:D8 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | CORRIDOR 8 002 | VAV-209 | NA | 850300 | NA | NA | NA | NA | 850301 | 8503 | NA | 1 |
| CO0576_VAV601 | VAV CLG | SIEMENS | 550-430PA | 7C:38:66:06:A8:B4 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | A130 | VAV-601 | NA | 850300 | NA | NA | NA | NA | 850302 | 8503 | NA | 2 |
| CO0576_VAV602 | VAV CLG | SIEMENS | 550-430PA | 7C:38:66:06:A8:9C | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | AUDITORIUM-A132 | VAV-602 | NA | 850300 | NA | NA | NA | NA | 850303 | 8503 | NA | 3 |
| CO0576_VAV603 | VAV CLG | SIEMENS | 550-430PA | 7C:38:66:06:A2:EA | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | A134-B | VAV-603 | NA | 850300 | NA | NA | NA | NA | 850304 | 8503 | NA | 4 |
| CO0576_VAV331 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:42:EA:34 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | SUPPLIES A238 | VAV-331 | NA | 850300 | NA | NA | NA | NA | 850305 | 8503 | NA | 5 |
| CO0576_VAV301 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:B7:B0 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | WRKSTNS A-01 | VAV-301 | NA | 850300 | NA | NA | NA | NA | 850306 | 8503 | NA | 6 |
| CO0576_VAV302 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:42:D5:B7 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | WRKSTNS A-01 | VAV-302 | NA | 850300 | NA | NA | NA | NA | 850307 | 8503 | NA | 7 |
| CO0576_VAV305 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:42:08:F1 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | WRKSTNS A-01 | VAV-305 | NA | 850300 | NA | NA | NA | NA | 850308 | 8503 | NA | 8 |
| CO0576_VAV304 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:BD:D8 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | WRKSTNS A-01 | VAV-304 | NA | 850300 | NA | NA | NA | NA | 850309 | 8503 | NA | 9 |
| CO0576_VAV224 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:A8:B4 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | WRKSTNS A-02 | VAV-224 | NA | 850300 | NA | NA | NA | NA | 850310 | 8503 | NA | 10 |
| CO0576_VAV215 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:A8:9C | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | A304 | VAV-215 | NA | 850300 | NA | NA | NA | NA | 850311 | 8503 | NA | 11 |
| CO0576_VAV213 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:A2:EA | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | SUPPLIES A332 | VAV-213 | NA | 850300 | NA | NA | NA | NA | 850312 | 8503 | NA | 12 |
| CO0576_VAV212 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:42:EA:34 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | OFFICE 180-A340 | VAV-212 | NA | 850300 | NA | NA | NA | NA | 850313 | 8503 | NA | 13 |
| CO0576_VAV210 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:B7:B0 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | PAYMENT PROCESSING A322 | VAV-210 | NA | 850300 | NA | NA | NA | NA | 850314 | 8503 | NA | 14 |
| CO0576_VAV214 | VAV WITH HWRHT | SIEMENS | 550-495PA | 7C:38:66:42:D5:B7 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | CORR B | VAV-214 | NA | 850300 | NA | NA | NA | NA | 850315 | 8503 | NA | 15 |
| CO0576_VAV211 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:42:08:F1 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | OFFICE 120-A324 | VAV-211 | NA | 850300 | NA | NA | NA | NA | 850316 | 8503 | NA | 16 |
| CO0576_VAV204 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:BD:D8 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | WRKSTNS B-02 | VAV-204 | NA | 850300 | NA | NA | NA | NA | 850317 | 8503 | NA | 17 |
| CO0576_VAV208 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:A8:B4 | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | 8404 | VAV-208 | NA | 850300 | NA | NA | NA | NA | 850318 | 8503 | NA | 18 |
| CO0576_VAV201 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:A8:9C | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | OFFICE A318 | VAV-201 | NA | 850300 | NA | NA | NA | NA | 850319 | 8503 | NA | 19 |
| CO0576_VAV217 | VAV WITH HWRHT | SIEMENS | 550-430PA | 7C:38:66:06:A2:EA | B-ASC | BACnet MS/TP | 2.1.5.15 | BU50 | CORR D | VAV-217 | NA | 850300 | NA | NA | NA | NA | 850320 | 8503 | NA | 20 |
| CO0576_JACE01 | DFC85 Local GUI | Tridium | JACE-8000 | 7C:38:66:42:EA:34 | B-BC | BACnet/IP | 4.2 | Qnx | Mech A124 | DFC85 BAS | NA | NA | 192.168.177.22 | 255.255.255.0 | 192.168.217.1 | 47808 | 859910 | 8500 | NA | NA |
Modbus Device Schedule
| Modbus Device Schedule | ||||||||||||||||
| Contractor/Vendor | GSA IT/OFM AMS | |||||||||||||||
| Device Name | Description | Manufacturer | Model | HW MAC Address | Device Type | SW Version | FW Version | Location | Controlled Equipment | RTU Net Supported | RTU Network | IP Address | Subnet Mask | Default Gateway | TCP Port | RTU Add |
EXAMPLE Modbus Device Schedule
| Modbus Device Schedule | ||||||||||||||||
| Contractor/Vendor | GSA IT/OFM AMS | |||||||||||||||
| Device Name | Description | Manufacturer | Model | HW MAC Address | Device Type | SW Version | FW Version | Location | Controlled Equipment | RTU Net Supported | RTU Network | IP Address | Subnet Mask | Default Gateway | TCP Port | RTU Add |
| CO0576_EL.MSB1_Meter | Main Elec Meter | Square D | ION8600 | 7C:38:66:06:A2:EA | Meter | 2.7.6 | ION5.2 | Elec A124-A | Advanced Metering | RTU-85-1 | NA | 192.168.177.4 | 255.255.255.0 | 192.168.177.1 | 502 | 0 |
| CO0576_DW.Main_Meter | Main DW Meter | Badger | M3000 | NA | Meter | US3.2 | 2.2.54 | Mech A124 | Advanced Metering | NA | RTU-85-1 | NA | NA | NA | NA | 1 |
| CO0576_NG.Main_Meter | Main Gas Meter | Rosemount | 8800D | NA | Meter | VOR | D1.1 | Outside N Wall | Advanced Metering | NA | RTU-85-1 | NA | NA | NA | NA | 2 |
| CO0576_TE.CHW_Meter | CHW BTU Meter | Onicon | System 10 | NA | Meter | BTU_1.1 | 10.2.5 | Mech A124-B | Advanced Metering | NA | RTU-85-1 | NA | NA | NA | NA | 3 |
HELP
| Tab/Section/Field | Description |
| BACnet Device Schedule | This tab is used to list BACnet device information |
| BAS Contractor/Vendor | This section is to be completed by the contractor/vendor |
| Device Object Name | This field should contain the GSA Data Normalization for Building Automation Systems standard-compliant Device Object Name that the contractor/vendor has determined is appropriate for the device |
| Description | This field should contain a description of the device that will be used in the Description device BACnet property - a BACnet client reading the Description property of the device should see this description |
| Manufacturer | This field should contain the name of the manufacturer of the device, and a BACnet client should be able to read this information in the device properties |
| Model | This field should contain the specific model of the device, and a BACnet client should be able to read this information in the device properties |
| HW MAC Address | This field is for IP-based devices only, and should contain the unique hardware MAC address of the specific device to be provided - this information may not be available until the project materials have been procured and delivered to the site - mark "TBD" until this information is available - it is absolutely required at least two (2) weeks prior to connecting the device to the GSA IP network |
| Device Type | This field should contain the BACnet standard device type that applies to the device: B-BC, B-AAC, B-ASC, B-SA, B-SS, B-AWS, B-OWS, B-OD, B-RTR, B-GW |
| Net type | This field should contain the type of BACnet network that the device will reside on: BACnet/IP or BACnet MS/TP |
| SW Version | This field should contain the actual application software version to be provided - this may not be available until the device is installed - mark "TBD" until the information is available |
| FW Version | This field should contain the firmware version of the device - for IP-based devices this information is required for approval prior to material procurement - for all other devices "TBD" may be used until the device is installed |
| Location | This field should contain the location of the device that will be used in the Location device BACnet property - a BACnet client reading the Location property of the device should see this location - it should not be ambiguous - should be a specific room number |
| Controlled Equipment | This field should describe the equipment that is controlled/monitored by the device |
| MS/TP Net(s) Supported | This field should list the BACnet MS/TP network(s) that the device serves as a B-RTR for - these networks should be uniquely-identified, and will be modified by GSA when Network Numbers are assigned - mark "NA" if the device is not an MS/TP router |
| Host Controller | If the device is an MS/TP device, this field should uniquely identify the B-RTR for this device - this will be modified by GSA when Device Instances are assigned |
| GSA IT/OFM Controls | This section is to be completed by GSA - leave this area blank |
| IP Address | This is the IP address assigned by GSA |
| Subnet Mask | This is the Subnet Mask assigned by GSA |
| Default Gateway | This is the Default Gateway assigned by GSA |
| UDP Port | This is the UDP port assigned by GSA |
| Device Instance | This is the Device Instance assigned by GSA |
| Network # | This is the Network Number assigned by GSA |
| BBMD | This field indicates whether the device should be configured as a BBMD |
| MS/TP Add | This is the MS/TP MAC address assigned by GSA |
| Section/Field | Description |
| Modbus Device Schedule | This tab is used to list Modbus device information |
| Contractor/Vendor | This section is to be completed by the contractor/vendor |
| Device Name | This field should contain the GSA Data Normalization for Building Automation Systems standard-compliant Device Object Name that the contractor/vendor has determined is appropriate for the device |
| Description | This field should contain a description of the device |
| Manufacturer | This field should contain the name of the manufacturer of the device |
| Model | This field should contain the specific model of the device |
| HW MAC Address | This field is for IP-based devices only, and should contain the unique hardware MAC address of the specific device to be provided - this information may not be available until the project materials have been procured and delivered to the site - mark "TBD" until this information is available - it is absolutely required at least two (2) weeks prior to connecting the device to the GSA IP network |
| Device Type | This field should contain a description of the device type, for example: meter, PLC, SCADA, VFD, etc. |
| SW Version | This field should contain the actual application software version to be provided - this may not be available until the device is installed - mark "TBD" until the information is available |
| FW Version | This field should contain the firmware version of the device - for IP-based devices this information is required for approval prior to material procurement - for all other devices "TBD" may be used until the device is installed |
| Location | This field should contain the location of the device - it should not be ambiguous - should be a specific room number |
| Controlled Equipment | This field should describe the equipment that is controlled/monitored by the device |
| RTU Net Supported | This field should list the Modbus RTU network that the device supports as a Modbus RTU-to-TCP converter - this network should be uniquely-identified, and the name will be modified by GSA when network configuration information is assigned - mark "NA" if the device is not a Modbus RTU-to-TCP converter |
| RTU Network | This field should identify the Modbus RTU network that the device resides on - if this device is an RTU-to-TCP converter, this field should be marked "NA" |
| GSA IT/OFM BAS/AMS | This section is to be completed by GSA - leave this area blank |
| IP Address | This is the IP address assigned by GSA |
| Subnet Mask | This is the Subnet Mask assigned by GSA |
| Default Gateway | This is the Default Gateway assigned by GSA |
| TCP Port | This is the TCP port assigned by GSA |
| RTU Add | This is the RTU address assigned by GSA |
File details come from the government source that posted it.