47PG0118R0008_-_Amendment_01_-_3.6.2018.pdf
PDF 106 KB Posted
- Attached to
- GSA Region 6 Boiler Inspection Services
- Solicitation number
- 47PG0118R0008
About this file
Amendment 01
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
Hai H. Nguyen
Solicitation 47PG0118R0008 for GSA Region 6 Boiler and Pressure Vessel Inspection Services is hereby amended as follows:
1. Answers that were received in a timely manner by the question due date of March 5, 2018 at 5:00p.m. CST are attached to this amendment. The question and answer period is hereby closed.
2. The proposal due date remains unchanged at March 15, 2018 at 2:00p.m. CST.
3. All terms other terms and conditions remain unchanged.
General Services Administration Services Acquisition Branch (6P1QC) 2300 Main Street, 7NW Kansas City, MO 64108
See Block 6
47PG0118R0008
1 3
03/06/2018
02/27/2018
Solicitation 47PG0118R0008 Boiler Inspection Question/Answer
1. If there is an incumbent contractor, please provide the contract number?
a. GS06P17GXC0003
2. Has a similar bid already been awarded in the past? Can you provide some information on the prior award? Specifically, we are looking for contractor name and bid price.?
a. The prior award was $33,958.00. The Contractor was Argent Inspections Inc.
3. Who is responsible for testing the controls and the relief valves? The industry is heading in the direction that the inspector is not supposed to touch anything on the boiler so as to avoid liability. The procedure that is developing is for someone representing the client's staff should test the controls and pull the relief valve test lever while the inspector directs and observes.
a. The inspector will be accompanied by an O&M contract employee who can operate the valves under the director and observation of the inspector.
4. Will GSA accept a track record of proven performance in lieu of National Board certification?
a. No. Please see the Personal Qualifications section of the Combined
Synopsis/Solicitation
5. In order to determine how much time will be required to inspect each pressure vessel, please provide the drawing for each or table with service and dimensions.
a. No. This has not been needed for contractors who have bid and performed the work successfully in the past 15 years. I am unaware of any major changes to PV inspections in the past year that would require this information.
6. In order to determine how much time will be required to inspect each boiler, please provide the drawings for each or a table with manufacturer, type, capacity, WAWP, fuels fired, and overall dimensions.
a. No. See answer under question 5.
7. What are the entrance requirements for each building? On arrival, how long will it take for security, safety, and escort?
a. If the contractor has secured his inspectors’ security clearances as required, and the contractor’s inspectors arrive on the date and time he arranged for with the
GSA POC at each building, access to the building will simply be the inspector walking in the office at the location and letting the POC know the inspector is there. See Section IX of the solicitation for security requirements.
8. What restrictions will there be on electronic equipment? In particular, cell phones, cameras, ultrasonic thickness gauges, borescopes, laptop computers?
a. None- if the Contractor’s inspectors have their security clearances. See Section
IX of the solicitation for security requirements.