36E77620R0004-015.pdf
PDF Posted
- Solicitation number
- 36E77620R0004
About this file
This notice provides details for the replacement of patient lift systems at the Minneapolis VA Medical Center. The Department of Veterans Affairs intends to solicit bids and award a firm-fixed-price design-build contract to replace 49 ceiling lifts in the SCI/D building and install 15 additional lifts in the ED building. The project delivery method will be design-build. The solicitation period is expected to begin on November 30, 2019, with a period of performance of approximately 275 calendar days from notice to proceed. The NAICS code is 236220 for commercial and institutional building construction, with a size standard of $36.5 million. The solicitation will be set aside for Service-Disabled Veteran-Owned Small Businesses. All questions must be submitted in writing by the specified date. The estimated value of construction is between $1 million and $2 million.
36E77620R0004 SOW - ATTACHMENT 1 - 2014.01.02 VA MPLS ED CD ISSUE DRAWINGS COMPLETE SET-2 - Part I.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36E77620R0004-0005000.docx | DOCX document | |
| 36E77620R0004-0005001.docx | DOCX document | |
| 36E77620R0004-0004012.docx | DOCX document | |
| 36E77620R0004-0004013.pdf | ||
| 36E77620R0004-0003001.docx | DOCX document | |
| 36E77620R0004-0003000.docx | DOCX document | |
| 36E77620R0004-0002000.docx | DOCX document | |
| 36E77620R0004-0002001.docx | DOCX document | |
| 36E77620R0004-0001000.docx | DOCX document | |
| 36E77620R0004-0001001.pdf | ||
| 36E77620R0004-014.docx | DOCX document | |
| 36E77620R0004-027.pdf | ||
| 36E77620R0004-018.docx | DOCX document | |
| 36E77620R0004-023.docx | DOCX document | |
| 36E77620R0004-024.docx | DOCX document | |
| 36E77620R0004-016.pdf | ||
| 36E77620R0004-013.docx | DOCX document | |
| 36E77620R0004-021.docx | DOCX document | |
| 36E77620R0004-017.zip | ZIP file | |
| 36E77620R0004-022.docx | DOCX document | |
| 36E77620R0004-026.pdf | ||
| 36E77620R0004-019.docx | DOCX document | |
| 36E77620R0004-020.docx | DOCX document | |
| 36E77620R0004-025.docx | DOCX document |
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOLOGY LEGEND
AS10
SHEET NO. SEQUENCE
DISCIPLINE
SHEET NUMBER
SHEET NUMBER
NORTH ARROW
1A A
GRID BUBBLES
NEW EXISTING
1 View Name 1/8" = 1'-0"
PLAN OR DETAIL NUMBER
DRAWING/DETAIL SCALE
PLAN OR DETAIL TITLE
PLAN OR DETAIL TITLE
0 4' 8' 16' 32' 48'
SCALE: 1/16" = 1'-0"
GRAPHIC SCALE
A3-01 A5-80
NEW DEMOLITION
INTERIOR ELEVATION REFERENCE
A3-01
NEW DEMOLITION
EXTERIOR ELEVATION REFERENCE
SHEET ON
WHICH
ELEVATION
IS DRAWN
SHEET ON
WHICH
ELEVATION
IS DRAWN
A101
SIM
SHEET ON WHICH
SECTION IS DRAWN
BUILDING SECTION NUMBER
ARROW & TAIL
INDICATE DIRECTION
OF SECTION
BUILDING SECTION REFERENCE
A101
SIM
SHEET ON WHICH
SECTION IS DRAWN
WALL SECTION NUMBER
ARROW & TAIL
INDICATE DIRECTION
OF SECTION
WALL SECTION REFERENCE
A101
SIM
SHEET ON WHICH
SECTION IS DRAWN
DEMOLITION SECTION NUMBER
ARROW & TAIL
INDICATE DIRECTION
OF SECTION
DEMOLITION SECTION REFERENCE
A101
SIM
SHEET ON WHICH
SECTION IS DRAWN
DETAIL SECTION NUMBER
TAIL INDICATES
DIRECTION OF
SECTION
WALL SECTION REFERENCE
A101
SIM
SHEET ON WHICH
SECTION IS DRAWN
DETAIL SECTION NUMBER
DETAIL CALLOUT REFERENCE
Room Name Room Name 0-0000
Room Name 0-0000
NET SF
OCC =
Room Name 0-0000
NET SF
ROOM NAME W/ ROOM NUMBER W/ AREA W/ OCCUPANCY LOAD
FINISH TAGS
DOOR TAG WINDOW TAG LOUVER TAG
D101A
WALL TAG CEILING TAGS
HEIGHT A.F.F.
CEILING TYPE
A3.2S NA 8'-0" AFF
LEVEL NAME
EL 0'-0"
SPOT ELEVATIONS LEVEL HEADS
EL: 8'-0" AFF
BORROWED LITE
TAG
L1W101A
BASE
FLOOR
WALL
MATCHLINE REFERENCE CENTERLINE TAG
REVISION CALLOUT
AND CLOUD
FLOW ARROW
REFERENCE
KEYNOTES
MATCHLINE SEE 1 / A101 CL
XXX
_ACM_Height
Depth
Model
Width
CASEWORK TAG
Ref
1R ef
Ref
1 R ef
PLAN
NORTH
PLAN
NORTH
PROJECT NORTH PROJECT NORTH
AND TRUE NORTH
A5-80
Ref
1R ef
Ref
1 R ef
NUMBER ON
SHEET
NUMBER ON
SHEET
BASE
FLOOR WALL
TRUE
NORTH
W1
FLUORESCENT LIGHT
(2'-0"x4'-0")
FLUORESCENT LIGHT
(2'-0"x2'-0")
REFLECTED CEILING PLAN SYMBOLS
L
CEILING MTD MICROPHONE
SECURITY CAMERA sc
PENDANT LIGHT
DOWNLIGHT
EXIT LIGHT
SPRINKLER HEADS
CONCEALED
SMOKE DETECTORS
SPEAKERS
FIRE ALARM/HORN/STROBE
RADIANT PANEL
STRIP LIGHTS
LINEAR DIFFUSER
RETURN/EXHAUST GRILLE
SUPPLY AIR DIFFUSER
PENDANT LIGHT
WALL WASH LIGHT
ACCESS PANEL (2'-0"x2'-0" UNO)
M
F
SD
S
RP
AP
CLOSED CIRCUIT CCTV
SPRINKLER HEADS
SEMI RECESSED
SPRINKLER HEADS
PENDANT
SPRINKLER HEADS
DELUGE
WOOD (FINISH)
PLYWOOD
FIBEROUS INSULATION
EXPANSION MATERIAL
WOOD BLOCKING
OR FRAMING
METAL
RIGID INSULATION
SHIM
GRADE
TERRAZZO
BRICK
STONE
EARTHWORK FILL
CONCRETE
CONCRETE
MASONRY UNIT
TILE (CERAMIC
OR QUARRY)
PLASTER, SAND,
GYPSUM BOARD,
PARTICLE BOARD
LEGEND OF MATERIALS
Drawing Title
Approved:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Dwg. of
Office of Facilities
Management
FULLY SPRINKLERED
GE
NE
RA
L
NO
TE
S:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED BY THE VARIOUS SUBCONTRACTORS. Approved:
Drawing Scale:
Plot Scale:
12" = 1'-0"
AS NOTED
Department of Veterans Affairs
TRUE
NORTH
PLAN NORTH
F
E
D
C
B
A on e-ei gh th in o ne fo ot
6" 6"
6" 6" on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot th re e in ch es o ne fo ot
1272-70-
1/ 2/
1:
:5
PM
C:
\U se rs\ cm cd an iel
\D oc um en ts\
1 A
RC
H
VA
M
PL
S
ED
C
EN
TR
AL
_C
Mc Da nie l.rv t 1/2
/20
:22
:54 P
M
GI02
DRAWING INDEX, GENERAL NOTES
AND SYMBOLS
VA MINNEAPOLIS ED
RENOVATION 13441
PR EB/TD01/02/2014
618-14-104
ONE VETERANS DRIVE
MINNEAPOLIS, MN 55417
2 73
CONSTRUCTION DRAWING INDEX
SHEET DRAWING NUMBER DRAWING NAME REV.
1 1272-70 GI01 PROJECT COVER SHEET
2 1272-70 GI02 DRAWING INDEX, GENERAL NOTES AND SYMBOLS
3 1272-70 GI03 ABBREVIATIONS
4 1272-70 GI04 WORK PHASE PLAN DIAGRAM
5 1272-70 AS01 LIFE SAFETY CODE NOTES
6 1272-70 AS02 FIRST FLOOR LIFE SAFETY PLAN
7 1272-70 AS03 FIRST FLOOR DEMOLITION PLAN
8 1272-70 AS04 FIRST FLOOR OVERALL PLAN
9 1272-70 AS05 FIRST FLOOR FINISHES AND WALL PROTECTION PLAN
10 1272-70 AS06 FIRST FLOOR FURNITURE AND EQUIPMENT PLAN
11 1272-70 AS07 FIRST FLOOR SIGNAGE PLAN
12 1272-70 AS08 FIRST FLOOR REFLECTED CEILING PLAN
13 1272-70 AS09 ENLARGED VESTIBULE PLANS ELEVATIONS AND SECTIONS
14 1272-70 AS10 ENLARGED DECONTAMINATION PLANS ELEVATIONS AND SECTIONS
15 1272-70 AS11 EXTERIOR DETAILS
16 1272-70 AS12 EXTERIOR DETAILS
17 1272-70 AS13 ENLARGED PLANS AND ELEVATIONS
18 1272-70 AS14 ENLARGED PLANS AND ELEVATIONS
19 1272-70 AS15 ENLARGED PLANS AND ELEVATIONS
20 1272-70 AS16 ENLARGED PLANS AND ELEVATIONS
21 1272-70 AS17 INTERIOR ELEVATIONS - TYPICAL MOUNTING HEIGHTS
22 1272-70 AS18 INTERIOR DETAILS, PARTITION TYPES
23 1272-70 AS19 INTERIOR DETAILS, PARTITIONS
24 1272-70 AS20 DOOR/OPENING & EQUIPMENT SCHEDULE
25 1272-70 AS21 DOOR TYPES, FRAME TYPES, DOOR AND MISC DETAILS
26 1272-70 AS22 INTERIOR DETAILS, CASEWORK SCHEDULE AND DETAILS
27 1272-70 AS23 INTERIOR DETAILS, CASEWORK DETAILS
28 1272-70 AS24 INTERIOR DETAILS, FINISHES AND WALL PROTECTION
29 1272-70 AS25 INTERIOR DETAILS, CEILINGS
30 1272-70 AS26 INTERIOR DETAILS, SIGNAGE
31 1272-70 AS27 ENLARGED PLANS AND ELEVATIONS ADD OPTIONS
32 1272-70 SS1 STRUCTURAL GENERAL NOTES
33 1272-70 SS2 FND. & FRAMING PLANS
34 1272-70 SS3 SECTIONS AND DETAILS
35 1272-70 M01 MECHANICAL TITLE SHEET
36 1272-70 PL01 BASEMENT INTERSTITIAL PLUMBING DEMOLITION PLAN
37 1272-70 PL02 FIRST FLOOR PLUMBING DEMOLITION PLAN
38 1272-70 PL03 FIRST FLOOR INTERSTITIAL PLUMBING DEMOLITION PLAN
39 1272-70 PL04 BASEMENT INTERSTITIAL PLUMBING PLAN
40 1272-70 PL05 FIRST FLOOR PLUMBING PLAN
41 1272-70 PL06 FIRST FLOOR INTERSTITIAL PLUMBING PLAN
42 1272-70 MG01 FIRST FLOOR MEDICAL GAS DEMOLITION PLAN
43 1272-70 MG02 FIRST FLOOR INTERSTITIAL MEDICAL GAS DEMOLITION PLAN
44 1272-70 MG03 FIRST FLOOR MEDICAL GAS PLAN
45 1272-70 MG04 FIRST FLOOR INTERSTITIAL MEDICAL GAS PLAN
46 1272-70 MH01 FIRST FLOOR MECHANICAL DEMOLITION PLAN
47 1272-70 MH02 FIRST FLOOR INTERSTITIAL MECHANICAL DEMOLITION PLAN
48 1272-70 MH03 FIRST FLOOR MECHANICAL PLAN
49 1272-70 MH04 FIRST FLOOR MECHANICAL PLAN (BID OPTION #8)
50 1272-70 MH05 FIRST FLOOR INTERSTITIAL MECHANICAL PLAN
51 1272-70 MH06 FIRST FLOOR INTERSTITIAL MECHANICAL PLAN (BID OPTION #8)
52 1272-70 MP01 FIRST FLOOR INTERSTITIAL MECHANICAL PIPING DEMOLITION PLAN
53 1272-70 MP02 FIRST FLOOR INTERSTITIAL MECHANICAL PIPING PLAN
54 1272-70 MP03 FIRST FLOOR INTERSTITIAL MECHANICAL PIPING PLAN (BID OPTION #8)
55 1272-70 M02 ENLARGED DECONTAMINATION ROOM PLANS
56 1272-70 M03 ENLARGED FIRST FLOOR MECHANICAL ROOM PLANS
57 1272-70 P01 PLUMBING WASTE AND VENT RISER DIAGRAM
58 1272-70 P02 PLUMBING DOMESTIC WATER RISER DIAGRAM
59 1272-70 M04 MECHANICAL DETAILS
60 1272-70 M05 MECHANICAL DETAILS
61 1272-70 M06 MECHANICAL SCHEDULES
62 1272-70 M07 MECHANICAL SCHEUDLES
63 1272-70 M08 MECHANICAL AND ELECTRICAL SCHEDULES
64 1272-70 ES01 ELECTRICAL TITLE SHEET
65 1272-70 ES02 FIRST FLOOR LIGHTING DEMOLITION PLAN
66 1272-70 ES03 FIRST FLOOR POWER AND SYSTEMS DEMOLITION PLAN
67 1272-70 ES04 FIRST FLOOR INTERSTITIAL ELECTRICAL PLAN
68 1272-70 ES05 FIRST FLOOR LIGHTING PLAN
69 1272-70 ES06 FIRST FLOOR POWER PLAN
70 1272-70 ES07 FIRST FLOOR SYSTEMS PLAN
71 1272-70 ES08 ELECTICAL SCHEDULES AND DETAILS
72 1272-70 ES09 ELECTRICAL SCHEDULES
73 1272-70 ES10 ELECTRICAL SCHEDULES
PROJECT GENERAL INFORMATION
1. ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE NOTES, SYMBOLS AND GENERAL INFORMATION ON THIS SHEET AND SHEET GI03 AND THE
SPECIFICATIONS.
2. ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITH OTHER DISCIPLINE DRAWINGS AND THE SPECIFICATIONS.
3. DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS ONLY. VERIFY ALL DIMENSIONS PRIOR TO WORK. VERIFY ALL DISCREPANCIES BETWEEN FIELD CONDITIONS AND THE CONTRACT DOCUMENTS. IN THE EVENT OF DISCREPANCY, NOTIFY COR AND OBTAIN RESOLUTION BEFORE PROCEEDING. FAILURE TO NOTIFY COR WILL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO PERFORM THE WORK AS INTENDED BY THE CONTRACT DOCUMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL WORK ARISING FROM SUCH FAILURE TO COORDINATE DISCREPANCIES TO THE SATISFACTION OF COR.
4. FLOOR PLANS AND INTERIOR ELEVATIONS INDICATE SPECIFIC INFORMATION, SEE TYPICAL PARTITION DETAILS, TYPICAL DOOR DETAILS, TYPICAL CASEWORK TYPES, TOP TYPES, SHELF TYPES, NOTES AND TYPICAL DETAILS FOR TYPICAL CONSTRUCTION UNLESS INDICATED OTHERWISE.
5. ALL SLEEVES, OPENINGS, PENETRATIONS, ETC. FOR CONDUIT, CABLE TRAYS, PIPES AND DUCTS, ETC. THROUGH RATED PARTITIONS AND FLOOR SLABS ARE TO BE FIRE STOPPED IN ACCORDANCE WITH THE FIRE RATED ASSEMBLY DESIGN, APPLICABLE CODES AND LOCAL FIRE AUTHORITY REQUIREMENTS.
6. NOTIFY THE COR IF A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS.
BATHROOMS
1. SINGLE STALL BATHROOM. PROVIDE LAV. BASIN, MIRROR, SDISP, TPH, PTC, TOILET, GB-1A, GB-1B, GB-1C, SND.
CASEWORK
1. CASEWORK TYPES, TOP TYPES, SHELF TYPES, NOTES AND TYPICAL DETAILS, SEE ROOM FINISHES SCHEDULE, CASEWORK TYPICAL NOTES AND DETAILS.
CEILINGS
1. CEILING HEIGHT SHALL BE 9'-0" IN ROOMS, CORRIDORS, PASSAGES, ETC. ABOVE FLOOR LEVEL UNLESS OTHERWISE NOTED. SEE ALSO ROOM FINISHES SCHEDULE.
2. SPRINKLER HEADS SHOWN ON THE RCP'S ARE THOSE OF DESIGN CONCERN. ALL AREAS ARE REQUIRED TO BE SPRINKLERED. SEE SPRINKLER DRAWINGS.
3. CUBICLE CURTAIN TRACKS (CCT) WHERE INDICATED. SEE INTERIOR CEILING DETAILS FOR DIMENSIONS AND CONSTRUCTION DETAILS.
4. SEE TYPICAL CASEWORK SOFFIT DETAILS UNLESS NOTED OTHERWISE.
A. GYPBOARD/ACT SOFFIT AT 7'-2" AFF. UNO. ABOVE CASEWORK, SEE INTERIOR/CABINET ELEVATION & DETAILS FOR GYPBOARD SOFFIT WIDTH AND DEPTH UNLESS
NOTED OTHERWISE.
B. BOTTOM OF PLAM FILLER AT 7'-2" AFF. UNLESS NOTED OTHERWISE.
5. SEE TYPICAL GYPBOARD SOFFIT DETAILS UNLESS NOTED OTHERWISE.
A. GYPBOARD/ACT SOFFIT AT 7'-2" AFF. UNLESS NOTED OTHERWISE. ALIGN SOFFIT FLUSH WITH ADJACENT PARTITIONS WHERE APPLICABLE.
B. GYPBOARD/ACT SOFFIT IN OPENING/ CORRIDOR AT 7'-2" AFF. UNLESS NOTED OTHERWISE.
COORDINATION
1. VERIFY AND COORDINATE THE FOLLOWING WITH THE RESPECTIVE TRADES:
A. VERIFY ALL NEW AND EXISTING CONDITIONS, SIZES AND LOCATIONS OF MECH AND/OR ELEC PENETRATIONS PRIOR TO COMMENCEMENT OF ANY WORK.
B. LOCATIONS FOR BACKING/BLOCKING REQUIRED FOR MOUNTING ARCH, MECH AND/OR ELEC EQUIPMENT
C. CUTTING AND PATCHING FOR WORK REQUIRED BY MECH AND/OR ELEC
D. SIZES AND LOCATIONS OF MECH AND/OR ELEC CURBS AND PADS
E. SIZE & LOCATION OF CEILING OPENING WITH PTS SUPPLIER.
DRAWINGS
1. DEMOLITION PLANS, DEMOLITION AND SALVAGED ITEMS NOTES. SEE DEMOLITION PLANS AND GENERAL NOTES.
2. LIFE SAFETY PLANS LOCATES FIRE AND SMOKE RATED PARTITION, SEE AS02.
3. GYPBOARD PARTITION TYPES, NOTES AND TYPICAL DETAILS, SEE AS18 & AS19.
4. DOOR AND DOOR AND BORROWED LIGHT FRAME TYPES, FRAME PROFILES, NOTES AND TYPICAL DETAILS, SEE ROOM OPENING SCHEDULE AS20 AND AS21. LOCATE
DOORS IN PARTITIONS ADJACENT TO PERPENDICULAR WALLS, SEE AS21.
5. CASEWORK TYPES, TOP TYPES, SHELF TYPES, NOTES AND TYPICAL DETAILS, SEE AS22.
6. FINISHES ARE INDICATED IN THE FINISH SCHEDULE AND/OR FINISH PLANS, SEE ROOM FINISH SCHEDULE AND INTERIOR FINISH PLANS.
7. TYPICAL MOUNTING HEIGHTS OF FITTING, FIXTURES AND ACCESSORIES, SEE DRAWING AS17.
8. CONCRETE CURBS AND PADS FOR EQUIPMENT. LOCATIONS MAY BE NOTED ON THE ARCHITECTURAL DRAWINGS. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATIONS AND SPECIFIC SIZE AND CONFIGURATION OF THEIR EQUIPMENT. SEE AS11 & AS12
9. CORNER GUARDS AND OTHER WALL PROTECTION ARE TYPES AS INDICATED ON THE DRAWINGS. SEE DRAWINGS LISTED BELOW
A. FOR CORNER GUARDS (CG) AND HANDRAILS (HR), SEE AS24.
EXISTING CONDITIONS
1. PROTECT AND PRESERVE ALL EXISTING ITEMS TO REMAIN AND REPAIR AND/OR REPLACE ANY ITEMS DAMAGED DURING THE COURSE OF THE WORK TO THE
SATISFACTION AND APPROVAL OF THE ARCHITECT WITHOUT ADDITIONAL COST TO THE OWNER.
2. WHERE WORK OCCURS IN AREAS WITH EXISTING FINISHES TO REMAIN, REFINISH DISTURBED AREAS TO MATCH EXISTING FINISHES AND MATERIALS UNLESS NOTED
OR DIRECTED.
3. WHERE EXISTING MASONRY WALLS ARE REMOVED OR NEW OPENINGS PROVIDED WITHIN EXISTING WALLS TO REMAIN, SAW CUTS SHALL BE USED FOR DEMOLITION
BETWEEN WALL SECTIONS SCHEDULED TO REMAIN AND WALL SECTIONS TO BE REMOVED.
4. FOR GENERAL DEMOLITION AND REPAIR NOTES, REFER TO DEMOLITION NOTES AND PLANS.
FITTING, FIXTURES, DEVICES AND ACCESSORIES
1. INSTALLATION OF FITTING, FIXTURES AND ACCESSORIES SHALL BE IN ACCORDANCE WITH TYPICAL MOUNTING HEIGHT SHEET UNLESS INDICATED OTHERWISE.
LIFE SAFETY
1. LIFE SAFETY PLANS LOCATE FIRE AND SMOKE RATED PARTITIONS, SEE ALSO FLOOR PLANS FOR PARTITION TYPES.
OWNER FURNISHED FURNITURE AND EQUIPMENT
1. FURNITURE AND EQUIPMENT SHOWN DASHED IS BY OTHERS. REFER TO FURNITURE AND EQUIPMENT CONSULTANT DRAWINGS AND INSTRUCTIONS FOR
INSTALLATION RESPONSIBILITIES.
2. THE FOLLOWING ABBREVIATIONS SHALL APPLY FOR CONTRACTOR FURNISHED/CONTRACTOR INSTALLED EQUIPMENT (CC) VA FURNISHED/CONTRACTOR INSTALLED
EQUIPMENT (VC) VA FURNISHED VA INSTALLED EQUIPMENT (VV).
3. PROVIDE ALL BLOCKING & ANCHORAGE AS NECESSARY FOR PROPER INSTALLATION OF ANY WALL MOUNTED ITEMS, SEE PARTITION BLOCKING DETAILS.
PARTITIONS
1. PLAN DIMENSIONS ARE TO OUTSIDE FACE OF PARTITIONS EXCLUDING DIRECTLY APPLIED FINISH MATERIAL SUCH AS CERAMIC TILE UNLESS NOTED OTHERWISE.
2. THE FACE OF EVERY PARTITION SHALL BE FLUSH WITHOUT OFFSETS. CHANGES IN PARTITION THICKNESS SHALL OCCUR AT CORNERS, PARTITION INTERSECTIONS OR OTHER FEATURES WHICH INTERRUPT THE PLANE OF THE PARTITION. FACE OF CORRIDOR PARTITIONS SHALL BE FLUSH FOR THE ENTIRE LENGTH OF THE CORRIDOR REGARDLESS OF CHANGES IN PARTITION THICKNESS, ALL ADJUSTMENTS SHALL BE MADE TO THE ROOM SIDE OF THE CORRIDOR PARTITION AND AT CORNERS.
3. FLOOR PLANS INDICATE GYPSUM BOARD PARTITION TYPES, SEE GYPSUM BOARD PARTITION NOTES AND DETAILS FOR HEIGHTS AND TYPICAL CONSTRUCTION UNLESS
INDICATED OTHERWISE. SEE AS18.
ROOM FINISHES
1. FINISHES ARE INDICATED IN THE ROOM FINISH SCHEDULE AND/OR FINISH PLANS.
ROOM OPENINGS
1. FLOOR PLANS INDICATE ROOM OPENING NUMBERS, SEE ROOM OPENING SCHEDULES FOR DOOR TYPE, FRAME TYPES, FRAME PROFILES, OPENING NOTES, AND TYPICAL
DETAILS.
2. LOCATE DOORS IN PARTITIONS ADJACENT TO PERPENDICULAR PARTITIONS IN ACCORDANCE WITH TYPICAL DETAIL UNLESS INDICATED OTHERWISE.
SPECIFICATION
1. SEE SPECIFICATION FOR FINISHES, MATERIALS, BUILDING ACCESSORIES, TOILET AND BATHROOM ACCESSORIES, TOILET PARTITIONS AND URINAL SCREENS, ETC
UNLESS NOTED OTHERWISE.
2. MATERIALS, PRODUCTS, SYSTEMS ETC IDENTIFIED ON THE DRAWINGS WITH EITHER "09260-11, 09510-1, ETC" OR "GYP-11, EXP-JT-21, ETC". REFER TO THE SPECIFICATION 09 0600 FOR BASIS OF DESIGN PRODUCT SELECTIONS AND OTHER REQUIREMENTS.
WALL BLOCKING AND ANCHORAGE
1. PROVIDE PLYWOOD WALL BLOCKING WHERE ARTWORK OR MBD AND TBD ARE SHOWN. EXTENT OF BLOCKING TO MATCH SIZE OF ARTWORK, MBD AND TBD. SEE
PARTITION BLOCKING DETAILS.
2. PROVIDE WALL BLOCKING FOR FITTINGS, FIXTURES AND ACCESSORIES IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS AND REQUIREMENTS. SEE
PARTITION BLOCKING DETAILS.
3. WALL MOUNTED LAVATORY BASIN BRACKET DETAILS, SEE TYPICAL PARTITION DETAILS.
WALL PROTECTION
1. CORNER GUARDS AND OTHER WALL PROTECTION ARE TYPES AS INDICATED ON THE DRAWINGS. SEE AS24 FOR DETAILS AND MOUNTING
No. Revisions Date
Drawing Title
Approved:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Dwg. of
Office of Facilities
Management
FULLY SPRINKLERED
GE
NE
RA
L
NO
TE
S:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED BY THE VARIOUS SUBCONTRACTORS. Approved:
Drawing Scale:
Plot Scale:
12" = 1'-0"
AS NOTED
Department of Veterans Affairs
TRUE
NORTH
PLAN NORTH
F
E
D
C
B
A on e-ei gh th in o ne fo ot
6" 6"
6" 6" on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot th re e in ch es o ne fo ot
1272-70-
1/ 2/
1:
:5
PM
C:
\U se rs\ cm cd an iel
\D oc um en ts\
1 A
RC
H
VA
M
PL
S
ED
C
EN
TR
AL
_C
Mc Da nie l.rv t 1/2
/20
:22
:57 P
M
GI03
ABBREVIATIONS VA MINNEAPOLIS ED
RENOVATION 13441
PR EB/TD01/02/2014
618-14-104
ONE VETERANS DRIVE
MINNEAPOLIS, MN 55417
3 73
A/C
A/C UNIT
A/E
AAMA
AB
ABC
ACI
ACS DR
ACS FLR
ACS PNL
ACST
ACT
AD
ADA
ADC
ADDL
ADDN
ADH
ADJ
ADMIN
AFF
AFG
AFS
AGC
AGGR
AHJ
AHR
AHU
AIA
AISC
ALT
ALT NO
ALUM
AMT
ANOD
ANSI
ANT
AP
APA
APPD
APPROX
AR
ARCH
ASB
ASI
ASKLR
ASPH
ASSN
ASTM
AT
ATCH
ATM
AUTO
AUX
AV
AVG
AW
AWI
AWPA
AWS
B PL
BAT
BD
BD FT
BEV
BHMA
BI FLD DR
BITUM
BKG
BLD
BLDG
BM
BOT
BRCG
BRDG
BRDG JST
BRG
BRG PL
BRKT
BRZ
BSMT
BTWN
BUR
C CONC
C TO C
CAB
CAC
CB
CBB
CCT
CCTV
CCW
CD
CEM
CEM PLAS
CER
CF
CF/CI
CF/OI
CFLG
CFMF
CG
CGSFU
CH
CHEM
CHFR
CHK
CI
CIP
CIR
CIRC
CJ
CL
CLDG
CLG
CLG HT
CLR
CM
CMU
CNR
CNTR
AIR CONDITION
AIR CONDITIONING UNIT
ARCHITECT/ENGINEER
AMERICAN ARCHITECTURAL MANUFACTURERS ASSN
ANCHOR BOLT
AGGREGATE BASE COURSE
AMERICAN CONCRETE INSTITUTE
ACCESS DOOR
ACCESS FLOOR
ACCESS PANEL
ACOUSTIC
ACOUSTICAL CEILING TILE
AREA DRAIN
AMERICANS WITH DISABILITIES ACT
AUTOMATIC DOOR CLOSER
ADDITIONAL
ADDITION
ADHESIVE
ADJACENT, ADJOINING, OR ADJUSTABLE
ADMINISTRATION
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ABOVE FINISHED SLAB
ASSOCIATED GENERAL CONTRACTORS
AGGREGATE
AUTHORITY HAVING JURISDICTION
ANCHOR
AIR HANDLING UNIT
AMERICAN INSTITUTE OF ARCHITECTS
AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALTERNATE
ALTERNATE NUMBER
ALUMINUM
AMOUNT
ANODIZE
AMERICAN NATIONAL STANDARDS INSTITUTE
ANTENNA
ACCESS PANEL
AMERICAN PLYWOOD ASSOCIATION
APPROVED
APPROXIMATE
AS REQUIRED
ARCHITECT
ASBESTOS
ARCHITECT'S SUPPLEMENTAL INSTRUCTION
AUTOMATIC SPRINKLER
ASPHALT
ASSOCIATION
AMERICAN SOCIETY FOR TESTING AND MATERIALS
ACOUSTICAL CEILING TILE
ATTACHMENT
AUTOMATIC TELLER MACHINE
AUTOMATIC
AUXILIARY
AUDIO VISUAL
AVERAGE
ACID WASTE
ARCHITECTURAL WOODWORKING INSTITUTE
AMERICAN WOOD PRESERVERS' ASSOCIATION
AMERICAN WELDING SOCIETY
BASE PLATE
BATTEN
BOARD
BOARD FEET (FOOT)
BEVEL
BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION
BIFOLDING DOORS
BITUMINOUS
BACKING
BUILD
BUILDING
BEAM OR BENCHMARK
BOTTOM
BRACING
BRIDGING
BRIDGING JOIST
BEARING
BEARING PLATE
BRACKET
BRONZE
BASEMENT
BETWEEN
BUILT-UP ROOFING
CAST CONCRETE
CENTER TO CENTER
CABINET
CEILING ATTENUATION CLASS
CATCH BASIN OR CORNER BEAD
CEMENTITIOUS (BACKER) BOARD
CUBICLE CURTAIN TRACK
CLOSED CIRCUIT TELEVISION
COUNTERCLOCKWISE
CONSTRUCTION DOCUMENTS OR CONTRACT DOCUMENTS
CEMENT
CEMENT PLASTER
CERAMIC
CONTRACTOR FURNISHED
CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CONTRACTOR FURNISHED/OWNER INSTALLED
COUNTERFLASHING
COLD-FORMED METAL FRAMING
CORNER GUARD
CERAMIC GLAZED STRUCTURAL FACING UNITS
COAT HOOK
CHEMICAL
CHAMFER
CHECK
CAST IRON
CAST-IN-PLACE
CIRCLE
CIRCULAR
CONSTRUCTION JOINT OR CONTROL JOINT
CENTER LINE
CLADDING
CEILING
CEILING HEIGHT
CLEAR
CONSTRUCTION MANAGEMENT
CONCRETE MASONRY UNIT
CORNER
COUNTER
CO
CO�
COL
COM
COMB
COMM
COMP
CONC
CONC FLR
COND
CONF
CONN
CONSTR
CONT
CONTR
COORD
CORR
CPM
CPRS
CPT
CR
CRS
CRSI
CSB
CSG
CSI
CSK
CSMT
CSWK
CT
CTG
CTR
CTRL
CTV
CU FT
CU IN
CU YD
CURT
CW
CYL
CYL L
D
DAT
DBL
DBL GLZ
DCS
DEG
DEL
DEMO
DEPT
DET
DF
DIA
DIAG
DIFF
DIM
DIR
DISP
DIST
DIV
DL
DOC
DR
DR CL
DR FR
DR OPNG
DS
DSGN
DW
DWG
E
EA
EFF
EFS
EIFS
EJ
EL
ELAST
ELEC
ELEC DR OP
ELEV
EMER
EMER SHR
ENCL
ENGR
ENVIR
EO
EPA
EPDM
EPO
EPS
EQ
EQL SP
EQUIP
EQUIV
ERD
ESC
ESMT
ESP
EST
ETC
EW
EWC
EWS
EXH
EXIST
EXP
EXP BT
EXST GR
EXT
EXT GR
F
FA
FAB
FAC
FACIL
FAS
FAS BD
FCO
FCTY
FD
FDC
FDTN
CARBON MONOXIDE
CARBON DIOXIDE
COLUMN
COMMON
COMBINATION, COMBINED
COMMUNICATION
COMPONENT
CONCRETE
CONCRETE FLOOR
CONDENSER OR CONDITION
CONFERENCE
CONNECT
CONSTRUCTION
CONTINUE
CONTRACTOR
COORDINATE
CORRIDOR
CRITICAL PATH METHOD
COMPRESSIBLE
CARPET MODULE TILE
CRASH RAIL
COLD ROLLED STEEL
CONCRETE REINFORCING STEEL INSTITUTE
CONCRETE SPLASH BLOCK
CASING
CONSTRUCTION SPECIFICATIONS INSTITUTE
COUNTER SUNK
CASEMENT
CASEWORK
CERAMIC TILE
COATING
CENTER
CONTROL
CABLE TELEVISION
CUBIC FEET
CUBIC INCH
CUBIC YARD
CURTAIN
CURTAINWALL
CYLINDER
CYLINDER LOCK
DEPTH OR PENNY (NAIL)
DATUM
DOUBLE
DOUBLE GLAZE
DIAPER CHANGING STATION
DEGREE
DELETE
DEMOLITION
DEPARTMENT
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIFFERENCE OR DIFFUSER
DIMENSION
DIRECTION
DISPENSER
DISTANCE
DIVIDE OR DIVISION
DEAD LOAD
DOCUMENT
DOOR, DRAIN, DRESSING ROOM, OR DRIVE
DOOR CLOSER
DOOR FRAME
DOOR OPENING
DOWNSPOUT
DESIGN
DISHWASHER
DRAWING
EAST
EACH
EFFICIENCY
EXTERIOR FINISH SYSTEM
EXTERIOR INSULATION AND FINISH SYSTEM
EXPANSION JOINT
ELEVATION
ELASTOMERIC
ELECTRIC
ELECTRIC DOOR OPENER
ELEVATOR
EMERGENCY
EMERGENCY SHOWER
ENCLOSURE
ENGINEER
ENVIRONMENT
ELECTRICAL OUTLET
ENVIRONMENTAL PROTECTION AGENCY
ETHYLENE PROPYLENE DIENE MONOMER
EMERGENCY POWER OFF
EXPANDED POLYSTYRENE BOARD (INSULATION)
EQUAL
EQUALLY SPACED
EQUIPMENT
EQUIVALENT
EXISTING ROOF DRAIN
ESCAPE OR ESCUTCHEON
EASEMENT
ESPECIALLY
ESTIMATE
AND SO FORTH OR ET CETERA
EACH WAY
ELECTRIC WATER COOLER
EYE WASH STATION
EXHAUST
EXISTING
EXPANSION OR EXPOSED
EXPANSION BOLT
EXISTING GRADE
EXTERIOR, EXTERNAL, OR EXTINGUISHER
EXTERIOR GRADE
FAHRENHEIT OR FEMALE
FIRE ALARM
FABRIC
FACTOR
FACILITY
FASCIA
FASCIA BOARD
FLOOR CLEANOUT
FACTORY
FLOOR DRAIN
FIRE DEPARTMENT CONNECTION
FOUNDATION
FE
FEC
FF
FF EL
FF&E
FGS
FHC
FHP
FIG
FIL
FIN
FIN FLR
FIN GR
FIN WD
FIXT
FL
FLASH
FLDG
FLEX
FLG
FLR
FLR FIN
FLR SK
FLUOR
FLUOR FIX
FM
FM-G
FO
FOC
FOF
FOM
FOS
FOUNT
FOW
FP
FR
FR SNK
FREQ
FRMG
FRP
FRZ
FS
FSTNR
FSTOP
FT
FTG
FTR
FURG
FURN
FUT
GA
GAL
GALV
GALV STL
GB
GC
GD
GDR
GEN
GFRC
GFRG
GFRP
GI
GL
GL BLK
GLU LAM
GR FL
GRAN
GRTG
GSB
GSM
GSU
GT
GUAR
GUT
GYB
GYP
GYP BD
GYP SHTG
H
HAZ MAT
HB
HC
HCWD
HDBD
HDO
HDR
HDW
HDWD
HEPA
HEX
HGR
HM
HMD
HMDF
HMF
HNDRL
HO
HORIZ
HOSP
HP
HQ
HR
HS
HSE
HSKPG
HST
HT
HVAC
HVY
HW
HYD
HYDR
IAQ
IBC
ID
ID NO
ILLUM
INCL
IND
INFO
INSUL
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FACE
FINISH FLOOR ELEVATION
FURNITURE, FIXTURE, AND EQUIPMENT
FOAM GASKET SEAL
FIRE HOSE CABINET
FULL HEIGHT PARTITION
FIGURE
FILLET
FINISH
FINISH FLOOR
FINISH GRADE
FINISH WOOD
FIXTURE
FLOORLINE
FLASHING
FOLDING
FLEXIBLE
FLOORING
FLOOR
FLOOR FINISH
FLOOR SINK
FLUORESCENT
FLUORESCENT FIXTURE
FACTORY MUTUAL
FACTORY MUTUAL GLOBAL
FINISHED OPENING
FACE OF CONCRETE OR FACE OF CURB
FACE OF FINISH
FACE OF MASONRY
FACE OF SLAB OR FACE OF STUD
FOUNTAIN
FACE OF WALL
FIRE PROTECTION OR FIREPROOF
FIRE RATING, FIRE RESISTANT, OR FRAME
FLUSHING RIM SINK
FREQUENCY
FRAMING
FIBERGLASS REINFORCED PLASTIC
FREEZER
FEDERAL SPECIFICATION
FASTENER
FIRE STOPPING
FEET OR FOOT
FOOTING
FIN TUBE RADIATION
FURRING
FURNISH OR FURNITURE
FUTURE
GAGE OR GYPSUM ASSOCIATION
GALLON
GALVANIC OR GALVANIZED
GALVANIZED STEEL
GRAB BAR
GENERAL CONTRACTOR
GUARD
GUARD RAIL
GENERAL OR GENERATOR
GLASS-FIBER-REINFORCED CONCRETE
GLASS-FIBER-REINFORCED GYPSUM
GLASS-FIBER-REINFORCED PLASTIC
GALVANIZED IRON
GLASS
GLASS BLOCK
GLUED LAMINATED WOOD
GROUND FLOOR
GRANITE
GRATING
GYPSUM SHEATHING BOARD
GALVANIZED SHEET METAL
GLAZED STRUCTURAL UNIT
GROUT
GUARANTEE
GUTTER
GYPSUM BOARD
GYPSUM
GYPSUM BOARD
GYPSUM SHEATHING BOARD
HIGH
HAZARDOUS MATERIALS
HOSE BIBB
HOLLOW CORE
HOLLOW CORE WOOD DOOR
HARDBOARD
HIGH DENSITY OVERLAY
HEADER
HARDWARE
HARDWOOD
HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HEXAGON
HANGER
HOLLOW METAL
HOLLOW METAL DOOR
HOLLOW METAL DOOR AND FRAME
HOLLOW METAL FRAME
HANDRAIL
HOLD OPEN
HORIZONTAL
HOSPITAL
HIGH PRESSURE
HEADQUARTERS
HANDRAIL
HEAT-STRENGTHENED (GLASS) OR HIGH STRENGTH
HOUSE
HOUSEKEEPING
HOIST
HEIGHT
HEATING, VENTILATING, AND AIR CONDITIONING
HEAVY
HOT WATER
HYDRANT
HYDRAULIC
INDOOR AIR QUALITY
INTERNATIONAL BUILDING CODE
INSIDE DIAMETER
IDENTIFICATION NUMBER
ILLUMINATION
INCLUDED
INDEPENDENT OR INDUSTRIAL
INFORMATION
INSULATION
INT
INTL
IVT
IWH
J
JAN
KD
KIT
KO
KPL
L
LAB
LAD
LAM
LAM GL
LAU
LAV
LBR
LBS
LD BRG
LDR
LED
LF
LIB
LIN
LIQ
LKR
LKR RM
LL
LMC
LMST
LRG
LRV
LT
LT GA
LT WT
LTG
LTNG
LVD
LVR
LWC
LWIC
LYR
MACH
MACH RM
MAINT
MAN
MATL
MATV
MAX
MBD
MCB
MD
ME
MEAS
MECH
MECH RM
MED
MEK
MEMB
MEMO
MEZZ
MF
MFD
MFG
MFR
MFR REC
MGT
MIC
MID
MIL STD
MIN
MIRR
MISC
MIT
MKR
ML
MLDG
MLWK
mm
MO
MOD
MOD BIT
MON
MOPR
MR
MS
MTD
MTG
MTL or MET
MULL
MW
MWP
N
NA
NAT
NATL
NC
NC
NCOMBL
NEC
NEG
NEMA
NEUT
NFC
NFPA
NIC
NO
NOM
NR
NRC
NRCA
NRP
NS
NUM
O/O O
OA
OC
OCC
OCT
OD
INTERIOR
INTERNATIONAL
IV TRACK
INSTANTANEOUS WATER HEATER
JUNCTION BOX
JANITOR
KILN DRIED OR KNOCKED DOWN
KITCHEN
KNOCKOUT
KICKPLATE
ANGLE
LABORATORY
LADDER
LAMINATE
LAMINATED GLASS
LAUNDRY
LAVATORY
LUMBER
POUND
LOAD-BEARING
LEADER
LIGHT EMITTING DIODE
LINEAR FEET (FOOT)
LIBRARY
LINEAR
LIQUID
LOCKER
LOCKER ROOM
LEAD LINED
LINEAR METAL CEILING
LIMESTONE
LARGE
LOUVERED ROOF VENT
LIGHT
LIGHT GAGE
LIGHTWEIGHT
LIGHTING
LIGHTNING
LOUVERED
LOUVER
LIGHTWEIGHT CONCRETE
LIGHTWEIGHT INSULATING CONCRETE
LAYER
MACHINE
MACHINE ROOM
MAINTENANCE
MANUAL
MATERIAL
MASTER ANTENNA TELEVISION SYSTEM
MAXIMUM
MARKERBOARD
METAL CORNER BEAD
DECK
MECHANICAL ENGINEER
MEASURE
MECHANICAL
MECHANICAL ROOM
MEDICAL, MEDIUM
METHYL ETHYL KETONE
MEMBRANE
MEMORANDUM
MEZZANINE
MILL FINISH
MANUFACTURED
MANUFACTURING
MANUFACTURER
MANUFACTURER'S RECOMMENDATION
MANAGEMENT
MICROPHONE
MIDDLE
MILITARY STANDARD
MINIMUM
MIRROR
MISCELLANEOUS
MITER
MARKER
METAL LATH
MOLDING (MOULDING)
MILLWORK
MILLIMETER
MASONRY OPENING
MODEL, MODIFY OR MODULE
MODIFIED BITUMEN
MONITOR
MOP RACK
MOISTURE RESISTANT
MOP SINK
MOUNTED
MOUNTING
METAL
MULLION
MICROWAVE
MEMBRANE WATERPROOFING
NORTH
NOT APPLICABLE
NATURAL
NATIONAL
NOISE CRITERIA
NURSE CALL
NONCOMBUSTIBLE
NATIONAL ELECTRICAL CODE
NEGATIVE
NATIONAL ELECTRICAL MANUFACTURERS ASSN
NEUTRAL
NATIONAL FIRE CODE
NATIONAL FIRE PROTECTION ASSOCIATION
NOT IN CONTRACT
NUMBER
NOMINAL
NOISE REDUCTION
NOISE REDUCTION COEFFICIENT
NATIONAL ROOFING CONTRACTORS ASSOCIATION
NONREMOVABLE
NARROW STILE
NUMERAL
OUT TO OUT
OXYGEN
OUTSIDE AIR OR OVERALL
ON CENTER
OCCUPY
OCTAGON
OUTSIDE DIAMETER, OUTSIDE DIMENSION
OF/CI
OFD
OFF
OF/OI
OH
OH DR
OPH
OPNG
OPP
OPR
OPT
OR
ORD
ORG
ORIG
ORN
OSHA
OUT
OZ
PAR
PARA
PART
PAT
PB
PBD
PC
PCA
PCC
PCCP
PCD
PCF
PCP
PED
PEN
PEND
PERF
PERIM
PERP
PHAR
PHOTO
PKG
PL
PL GL
PLAM
PLAS
PLBG
PLYWD
PMTL
PNEU
PNL
PO
POLY
PPC
PR
PRCST
PREFAB
PREFIN
PRELIM
PREP
PRESS
PREV
PRKG
PRMLD
PROJ
PROP
PSF
PSI
PT
PTC
PTN
PTS
PVC
PVG
PWR
QA
QC
QRY
QTR
QTY
QUAD
QUAL
R
RA
RAD
RB
RBM
RBR
RC
RCP
RCVR
RD
REC
RECD
RECPT
RECT
REF
REFR
REG
REINF
REP
REPL
REQ
REQD
RET
REV
RFG
RFI
RFP
RL
RLG
RM
RND
RO
ROW
RS
RSV
RT
RV
RVS
RWL
SA
SALV
OWNER FURNISHED/CONTRACTOR INSTALLED
OVERFLOW DRAIN
OFFICE
OWNER FURNISHED/OWNER INSTALLED
OVERHANG
OVERHEAD (COILING) DOOR
OPPOSITE HAND
OPENING
OPPOSITE
OPERABLE
OPTIONAL
OPERATING ROOM OR OUTSIDE RADIUS
ORDNANCE OR OVERFLOW ROOF DRAIN
ORGANIC
ORIGINAL
ORNAMENTAL
OCCUPATIONAL SAFETY AND HEALTH ADMINSTRATION
OUTLET
OUNCE
PARALLEL OR PARAPET
PARAGRAPH
PARTIAL
PATTERN
PUSHBUTTON
PARTICLEBOARD
PIECE, POLYCARBONATE OR PORTLAND CEMENT
PORTLAND CEMENT ASSOCIATION
PRECAST CONCRETE
CONCRETE PAVEMENT
PAPER CUP DISPENSER
POUNDS PER CUBIC FOOT
PORTLAND CEMENT PLASTER
PEDESTAL
PENETRATE
PENDANT
PERFORATED
PERIMETER
PERPENDICULAR
PHARMACY
PHOTOGRAPH
PACKAGE
PROPERTY LINE
PLATE GLASS
PLASTIC LAMINATE
PLASTER OR PLASTIC
PLUMBING
PLYWOOD
PAINTED METAL
PNEUMATIC
PANEL
POST OFFICE, PURCHASE ORDER
POLYETHYLENE (PLASTIC)
PERSONAL PROTECTION CONTAINER
PAIR
PRECAST
PREFABRICATE
PREFINISH
PRELIMINARY
PREPARATION
PRESSURE
PREVIOUS
PARKING
PREMOLDED
PROJECT
PROPERTY
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PAINT, PNEUMATIC TUBE, OR PRESSURE TREATED
PAPER TOWEL CABINET
PARTITION
PNEUMATIC TUBE STATION
POLYVINYL CHLORIDE (PLASTIC)
PAVING
POWER
QUALITY ASSURANCE
QUALITY CONTROL
QUARRY
QUARTER
QUANTITY
QUADRANT
QUALITY
RADIUS OR RISER
RETURN AIR
RADIATOR
RESILIENT BASE
REINFORCED BRICK MASONRY
RUBBER
REMOTE CONTROL
REFLECTED CEILING PLAN
RECEIVER
ROAD OR ROOF DRAIN
RECESSED
RECEIVED
RECEPTACLE
RECTANGLE
REFERENCE OR REFRIGERATOR
REFRACTORY, REFRIGERATION
REGISTER
REINFORCE
REPAIR
REPLACE
REQUIRE
REQUIRED
RETURN
REVISION
ROOFING
REQUEST FOR INFORMATION
REQUEST FOR PROPOSAL
ROOF LEADER
RAILING
ROOM
ROUND
ROUGH OPENING
RIGHT OF WAY
ROUGH SAWN
RESILIENT SHEET VINYL
RIGHT
ROOF VENT
REVERSE
RAIN WATER LEADER
SUPPLY AIR
SALVAGE
SAMP
SAN
SAT
SATC
SB
SBS
SBSTR
SC
SC
SCH
SCHED
SCHEM
SCP
SCRN
SCT
SCWD
SD
SDG
SDISP
SECT
SEG
SEL
SEP
SF
SFTWD
SGD
SGL
SHR
SHR HD
SHRD
SHT
SHTG
SHV
SIM
SJ
SJI
SK
SKLT
SLD WDW
SLDG
SLNT
SM
SMK
SND INS
SPEC
SPKLR
SPKR
SPLY
SPR
SQ
SQ IN
SQ YD
SS
SS
SST
ST
STC
STD
STIF
STL JST
STL LNTL
STL PL
STL RF DK
STL TB
STL TR
STNLS
STOR
STR
STRUCT
STRUCT STL
SUB
SURF
SUSP
SUSP CLG
SW
SWDR
SYM
SYNTH
SYS
T T&M
TBD
TECH
TEL
TEMP
THERM
THK
THRES
THRU
THRUOUT
TMPD
TMPD GL
TN
TO
TO FDN
TOB
TOM
TOP
TOS
TOW
TRANS
TRTD
TS
TSTAT
TV
TYP
U
UC
UGND
UL
ULT
UNFIN
UNO
UPS
UR
UTIL
UV
SAMPLE
SANITARY
SUSPENDED ACOUSTICAL TILE
SUSPENDED ACOUSTICAL TILE CEILING
SPLASH BLOCK
STYRENE BUTADIEN STYRENE
SUBSTRATE
SHADING COEFFICIENT OR SOLID CORE
SHARPS CONTAINER
SCHOOL
SCHEDULE
SCHEMATIC
SCUPPER
SCREEN
STRUCTURAL CLAY TILE
SOLID CORE WOOD DOOR
SMOKE DETECTOR
SIDING
SOAP DISPENSER
SECTION
SEGMENT
SELECT
SEPARATE
SQUARE FOOT (FEET)
SOFTWOOD
SLIDING GLASS DOOR
SINGLE
SHOWER
SHOWER HEAD
SHOWER DRAIN
SHEET
SHEATHING
SHELVING
SIMILAR
SCORED JOINT
STEEL JOIST INSTITUTE
SKETCH
SKYLIGHT
HORIZONTAL SLIDING WINDOW
SLIDING
SEALANT
SHEET METAL
SMOKE
SOUND INSULATION
SPECIFICATION
SPRINKLER
SPEAKER
SUPPLY
SINGLE PLY MEMBRANE ROOF SYSTEM
SQUARE
SQUARE INCH
SQUARE YARD
SOLID SURFACE (ARCH)
SANITARY SEWER OR SERVICE SINK (MECH)
STAINLESS STEEL
STAIRS OR STREET
SOUND TRANSMISSION CLASS
STANDARD
STIFFENER
STEEL JOIST
STEEL LINTEL
STEEL PLATE
STEEL ROOF DECK
STEEL TUBE
STEEL TRUSS
STAINLESS
STORAGE
STRINGERS
STRUCTURAL
STRUCTURAL STEEL
SUBSTITUTE
SURFACE
SUSPEND
SUSPENDED CEILING
SWITCH
SWING DOOR
SYMBOL
SYNTHETIC
SYSTEM
TREAD
TIME AND MATERIALS
TACKBOARD
TECHNICAL
TELEPHONE
TEMPERATURE OR TEMPORARY
THERMAL
THICKNESS
THRESHOLD
THROUGH
THROUGHOUT
TEMPERED
TEMPERED GLASS
TRUE NORTH
TOP OF ___
TOP OF FOUNDATION
TOP OF BEAM
TOP OF MASONRY
TOP OF PARAPET
TOP OF STEEL
TOP OF WALL
TRANSOM
TREATED
TUBE STEEL
THERMOSTAT
TELEVISION
TYPICAL
HEAT TRANSFER COEFFICIENT
UNDERCUT
UNDERGROUND
UNDERWRITERS LABORATORIES
ULTIMATE
UNFINISH
UNLESS OTHERWISE NOTED
UNINTERRUPTIBLE POWER SUPPLY
URINAL
UTILITY
ULTRAVIOLET
VAC
VAR
VD
VEH
VENT
VERT
VEST
VIC
VID
VIF
VNR
VOC
VOL
VR
VTR
W W W/ W/O
WBL
WC
WD
WDW
WF
WFR
WFS
WH
WHSE
WP
WPM
WR
WS
WSCT
WT
X BRACE
XPS
YD
VACUUM
VARIES
VOICE/DATA
VEHICLE
VENTILATION
VERTICAL
VESTIBULE
VICINITY
VIDEO
VERIFY IN FIELD
VENEER
VOLATILE ORGANIC COMPOUND
VOLUME
VAPOR RETARDER
VENT THROUGH ROOF
WIDE OR WEST
VINYL COATED WALL COVERING
WITH
WITHOUT
WOOD BLOCKING
WATER CLOSET
WOOD
WINDOW
WIDE FLANGE
WOOD FRAME
WOOD FURRING STRIPS
WATER HEATER
WAREHOUSE
WATERPROOFING
WATERPROOF MEMBRANE
WEATHER RESISTANT
WEATHERSTRIP
WAINSCOT
WEIGHT
CROSS BRACE
EXTRUDED POLYSTYRENE BOARD
YARD
ARCHITECTURAL ABBREVIATIONS
ENTRY
ENTRY
PHASE 1A - REMOVE
WALL & PATCH TO
MATCH EXISTING.
PROVIDE 2 DUPLEX
(TEMP) & DATA (TEMP)
& PANIC FOR TEMP.
DESK.
WAITING
PHASE 1
PHASE 1A - REMOVE
WALL & PATCH TO
MATCH EXISTING.
PHASE 1A - INSTALL
TEMP DOOR. PATCH
FINISHES TO MATCH
EXISTING.
1234567
9 10 11
13 14 15
TEMP.
TRIAGE
TEMP.
WAITING
Phase 1
PHASE 1A
INSTALL TEMP
SINK.
PHASE 1A
INSTALL TEMP
SINK.
PHASE 1A
INSTALL TEMP
SINK.
TEMP. DIRTY UTILITY
PHASE 1A - THIS RM.
WAS A TOILET AT ONE
TIME. SINK AND
TOILET HAVE BEEN
REMOVED. PROVIDE
AND INSTALL TEMP.
SINK AND TOILET.
PT
S
PHASE 1A - MAKE TWO
OFFICES OUT OF THE
FOUR. ADD WALLS TO
THE WEST SIDE AND
TEMP DOORS.
PHASE 1A - INSTALL
TEMP. WALL TO 7-FOOT
AFF. PAINT AND
INSTALL VINLY BASE.
PHASE 1A - REMOVE
CASEWORK, FRONT
AND BACK COUNTERS.
INSTALL A TEMPORARY
WALL AT THE FRONT
COUNTER SPACE. NO
TAPE. INSTALL WALL
TO UNDERSIDE OF
SUSPENDED CEILING.
MOVE EXISTING DOOR
TO WEST WALL. INFILL
DOOR OPEING.
INSTALL I/2 LOCKERS
SCHEDULED TO BE
INSTALLED IN THE NEW
LOCKER ROOMS.
WHEN NEW LOCKER
ROOMS ARE COMPLETE
REMOVE LOCKERS AND
INSTALL AT FINAL
LOCATION.
TEMP.
BREAK
ROOM
TEMP.
LOCKER
ROOM
INSTALL TEMP.
LOCKERS IN THIS
SPACE PRIOR TO
PHASE 2 START. WHEN
PHASE TWO LOCKER
ROOM IS COMPLETE
REINSTALL AT FINAL
LOCATION.
PT
S
2PHASE 1A - EXPAND IT
ROOM INTO
ELECTRICAL ROOM.
RELOCATE EXISTING
RACK AND
RETERMINATE AND
TEST CABLING TO
REMAIN.
TEMPORARILOY
RELOCATE RTLS
DEVICES AS REQUIRED
FOR ADEQUATE
COVERAGE DURING
CONSTRUCTION.
PHASE 1A -BUILD
TEMPORARY CLEAN
STORAGE FOR SPS.
REMOVE CARPET,
INSTALL TILE AND
BASE.
BALANCE HVAC
POSITIVE
4444 4
4444 4
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
DRILL
CORE
WCWCWCWC
WCWCWCWC
FF EE DD CC BB AA Z Y X W V
31.6
32.6
AA.1AA.8
31.7
AA.10
AA.11
AA.12
FF EE DD CC BB AA Z Y X W V
31.6
32.6
AA.1AA.8
31.7
AA.10
AA.11
AA.12
C1-1
C1-1
PTS
P
TS
PTS
P
TS
N
N
N
N
PTS
STAFFING
BOARD STAFFING
BOARD
ISOLATION
SUPPLIES
ISOLATION
SUPPLIES
PTS
STAFFING
BOARD STAFFING
BOARD
ISOLATION
SUPPLIES
ISOLATION
SUPPLIES
AMBULANCE
GARAGE
C1-151
CORRIDOR
C1-152
CORRIDOR
C1-153
CORRIDOR
CORRIDOR
C1-138
OUTPATIENT
LOBBYC1-3
AMBULANCE
GARAGE
C1-151
CORRIDOR
C1-152
CORRIDOR
C1-153
CORRIDOR
CORRIDOR
C1-138
OUTPATIENT
LOBBYC1-3
1V-112C
LINEN
CLOSET
1V-155
EXAM
1V-133
EXAM
1V-119
EXAM
1V-139
FAST
TRACK
1V-149
STORAGE
1V-100B
TOILET
1V-129
EXAM
C1-185
CORRIDOR
C1-184
CORRIDOR
C1-154
C1-182
CORRIDOR
C1-181
HALLWAY
C1-179
HALLWAY
C1-180
HALLWAY
C1-178
HALLWAY
C1-177
HALLWAY
C1-155
HALLWAY C1-174
HALLWAY
C1-176
HALLWAY
C1-159
HALLWAY
C1-175
HALLWAY
C1-158
HALLWAY
C1-157
HALLWAY
C1-156
HALLWAY
C1-165
HALLWAY
1V-128
EXAM
1V-109
EXAM
1V-110
EXAM
1V-127
EXAM -
BARIATRIC
1V-106
EXAM
1V-108
EXAM
1V-118
EXAM
1V-130
EXAM
1V-126
EXAM
1V-103
EXAM
1V-105
EXAM
1V-125
EXAM
1V-102
EXAM
1V-107
EXAM
1V-112B
SAFE EXAM
ALCOVE
1V-132
EXAM
1V-138
STORAGE
1V-116
EXAM -
ISOLATION
1V-111
EXAM -
BARIATRIC
1V-112
SAFE
EXAM
1V-100C
CHECK-IN/
POLICE
1V-150
HSKG
1V-147
ON
CALL
1V-146
OFFICE
1V-145
OFFICE
1V-144
OFFICE
1V-143
OFFICE
1V-142
OFFICE
1V-124
CENTRAL
SUPPLY
1V-113
TEAM
WORK
1V-114
TOILET -
BARIATRIC
1V-140A
TOILET
1V-140B
ANTE
1V-116B
ANTE
1V-116A
TOILET
1V-104
SOILED
1V-V02
DECONTAM
1V-V01
VESTIBULE
1V-100
WAITING
1V-101
BUSINESS
OFFICE
1V-131
TEAM
WORK
1V-115
TEAM
WORK
1V-141
SOILED
1V-134
TEAM
WORK
1V-153
PHYS WORK
AREA
1V-123
CLEAN
UTILITY
1V-154
CONF RM/
LOUNGE
1V-137
FAST
TRACK
1V-136
FAST
TRACK
1V-112A
TOILET
1V-121
TOILET
1V-120
TOILET
1V-135
CONSULTATION
1V-100A
TOILET
1V-140
EXAM -
ISOLATION
1V-117
TREATMENT
ROOM
1V-112C
LINEN
CLOSET
1V-155
EXAM
1V-133
EXAM
1V-119
EXAM
1V-139
FAST
TRACK
1V-149
STORAGE
1V-100B
TOILET
1V-129
EXAM
C1-185
CORRIDOR
C1-184
CORRIDOR
C1-154
C1-182
CORRIDOR
C1-181
HALLWAY
C1-179
HALLWAY
C1-180
HALLWAY
C1-178
HALLWAY
C1-177
HALLWAY
C1-155
HALLWAY C1-174
HALLWAY
C1-176
HALLWAY
C1-159
HALLWAY
C1-175
HALLWAY
C1-158
HALLWAY
C1-157
HALLWAY
C1-156
HALLWAY
C1-165
HALLWAY
1V-128
EXAM
1V-109
EXAM
1V-110
EXAM
1V-127
EXAM -
BARIATRIC
1V-106
EXAM
1V-108
EXAM
1V-118
EXAM
1V-130
EXAM
1V-126
EXAM
1V-103
EXAM
1V-105
EXAM
1V-125
EXAM
1V-102
EXAM
1V-107
EXAM
1V-112B
SAFE EXAM
ALCOVE
1V-132
EXAM
1V-138
STORAGE
1V-116
EXAM -
ISOLATION
1V-111
EXAM -
BARIATRIC
1V-112
SAFE
EXAM
1V-100C
CHECK-IN/
POLICE
1V-150
HSKG
1V-147
ON
CALL
1V-146
OFFICE
1V-145
OFFICE
1V-144
OFFICE
1V-143
OFFICE
1V-142
OFFICE
1V-124
CENTRAL
SUPPLY
1V-113
TEAM
WORK
1V-114
TOILET -
BARIATRIC
1V-140A
TOILET
1V-140B
ANTE
1V-116B
ANTE
1V-116A
TOILET
1V-104
SOILED
1V-V02
DECONTAM
1V-V01
VESTIBULE
1V-100
WAITING
1V-101
BUSINESS
OFFICE
1V-131
TEAM
WORK
1V-115
TEAM
WORK
1V-141
SOILED
1V-134
TEAM
WORK
1V-153
PHYS WORK
AREA
1V-123
CLEAN
UTILITY
1V-154
CONF RM/
LOUNGE
1V-137
FAST
TRACK
1V-136
FAST
TRACK
1V-112A
TOILET
1V-121
TOILET
1V-120
TOILET
1V-135
CONSULTATION
1V-100A
TOILET
1V-140
EXAM -
ISOLATION
1V-117
TREATMENT
ROOM
1V-149A
O2 STORAGE
1V-149A
O2 STORAGE
FF EE DD CC BB AA Z Y X W V
31.6
32.6
AA.1AA.8
31.7
AA.10
AA.11
AA.12
FF EE DD CC BB AA Z Y X W V
31.6
32.6
AA.1AA.8
31.7
AA.10
AA.11
AA.12
1T-108
C
1V-1461 Q A
1V-130
1V-128
1V-100D
C1-155
1R-138
1Q-123
1V-100E
1V-100C
1V-137 1V-138
1V-1341V-135
1V-102
1V-101
1V-1321V-133
1V-127
1V-129
1V-139
1V-140 1V-141
C1-174
1V-131
1V-142
1V-145
1R-110
1V-125
1V-119
1V-120
1V-107C
1V-107A
1V-105
1Q-117B
1V-100B
C
1V-100A
1V-100
1Q-117C
C1-153
Q
C
1V-106
V A
1V-103
1V-104
1V-124
1V-123
1V-122
1V-107
C1-165
1V-107B
1V-121
1V-108 1V-109
C1-152
1V-117
1V-151
C
1V-146A C1-171
C
C1-170
1V-113
1V-118 1V-112
1V-110 1V-111
1V-116
1V-115
1V-114
C1-180
1V-149
1V-150
1V-150A
1V-148 1V-147
C1-181
C1-176
C1-179
C1-178
C1-177
C1-176A
C1-183
T-
1T-106
1T-107
1S-1
1R-108
C
1R-109
C1-184A C1-185
T-
V F
V G
V H
1V-117A
R
1R-140
C1-138
C
C
C
C
C
1R-125
1R-124
1R-123
T-
T-
1R-139
C1-180
1T-108
C
1V-1461 Q A
1V-130
1V-128
1V-100D
C1-155
1R-138
1Q-123
1V-100E
1V-100C
1V-137 1V-138
1V-1341V-135
1V-102
1V-101
1V-1321V-133
1V-127
1V-129
1V-139
1V-140 1V-141
C1-174
1V-131
1V-142
1V-145
1R-110
1V-125
1V-119
1V-120
1V-107C
1V-107A
1V-105
1Q-117B
1V-100B
C
1V-100A
1V-100
1Q-117C
C1-153
Q
C
1V-106
V A
1V-103
1V-104
1V-124
1V-123
1V-122
1V-107
C1-165
1V-107B
1V-121
1V-108
1V-109
C1-152
1V-117
1V-151
C
1V-146A C1-171
C
C1-170
1V-113
1V-118 1V-112
1V-110 1V-111
1V-116
1V-115
1V-114
C1-180
1V-149
1V-150
1V-150A
1V-148 1V-147
C1-181
C1-176
C1-179
C1-178
C1-177
C1-176A
C1-183
T-
1T-106
1T-107
1S-1
1R-108
C
1R-109
C1-184A C1-185
T-
V F
V G
V H
1V-117A
R
1R-140
C1-138
C
C
C
C
C
1R-125
1R-124
1R-123
T-
T-
1R-139
C1-180
ENT
CHAIR
ENT
CHAIR
Drawing Title
Approved:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Dwg. of
Office of Facilities
Management
FULLY SPRINKLERED
GE
NE
RA
L
NO
TE
S:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED BY THE VARIOUS SUBCONTRACTORS. Approved:
Drawing Scale:
Plot Scale:
12" = 1'-0"
AS NOTED
Department of Veterans Affairs
TRUE
NORTH
PLAN NORTH
F
E
D
C
B
A on e-ei gh th in o ne fo ot
6" 6"
6" 6" on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot th re e in ch es o ne fo ot
1272-70-
1/ 2/
1:
:0
PM
C:
\U se rs\ cm cd an iel
\D oc um en ts\
1 A
RC
H
VA
M
PL
S
ED
C
EN
TR
AL
_C
Mc Da nie l.rv t 1/2
/20
:28
:07 P
M
GI04
WORK PHASE PLAN DIAGRAM VA MINNEAPOLIS ED
RENOVATION 13441
Checker Author01/02/2014
618-14-104
ONE VETERANS DRIVE
MINNEAPOLIS, MN 55417
4 73
1" = 20'-0"1 PHASING PLAN
No. Revisions Date
PHASE 1 PLAN DIAGRAM PHASE 2 PLAN DIAGRAM
EXISTING CONDITION PLAN DIAGRAM PHASE 1 & PHASE 2 PLAN DIAGRAM
CODE COMPLIANCE REVIEW - GENERAL
THE VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS
CODES, STANDARDS AND EXECUTIVE ORDERS
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON
THE TECHNICAL INFORMATION LIBRARY (TIL)
• INTERNATIONAL BUILDING CODE (IBC) - (SEE NOTES BELOW)
• NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• NFPA NATIONAL FIRE CODES WITH EXCEPTION OF NFPA 5000 AND NFPA 900
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
• VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• NATIONAL ELECTRICAL CODE (NEC)
• NATIONAL STANDARD PLUMBING CODE (NSPC)
• ASME BOILER AND PRESSURE VESSEL CODE
• ASME CODE FOR PRESSURE PIPING
• UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) INCLUDING VA SUPPLEMENT BARRIER FREE DESIGN
• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318)
• MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPAct)
• DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE
RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433,434 AND 435
• FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND TRANSPORTATION MANAGEMENT
• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA MASTER
CONSTRUCTION SPECIFICATION
• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE STANDARD 62.1-2004
• SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE STANDARD 15 -2007
• VA FIRE PROTECTION DESIGN MANUAL
PLUMBING FIXTURES:
IBC 2009 "TABLE 2902.1
RESIDENTIAL CARE, 161 OCCUPANTS.
WATER CLOSET 1 PER 10 (MALE/FEMALE), 17 MALE FIXTURES REQUIRED, 17 FEMALE FIXTURES REQUIRED, TOTAL 54 PROVIDED.
LAVATORIES 1 PER 10 (MALE/FEMALE), 17 MALE FIXTURES REQUIRED, 17 FEMALE FIXTURES REQUIRED, TOTAL 54 PROVIDED.
BATHTUB/SHOWER 1 PER 8 (MALE/FEMALE), 21 MALE FIXTURES REQUIRED, 21 FEMALE FIXTURES REQUIRED, TOTAL 52 PROVIDED.
DRINKING FOUNTAIN 1 PER 100, 2 REQUIRED, 2 PROVIDED VIA FILTERED WATER DISPENSING FRIDGE'S IN LOUNGES.
ONE SERVICE SINK REQUIRED. ONE PROVIDED ON SECOND AND THIRD FLOORS.
IBC 2009 2902.3.1 ACCESS TO FIXTURES: ACCESS TO THE REQUIRED FACILITIES SHALL BE FROM WITHIN THE BUILDING OR FROM THE EXTERIOR OF THE
BUILDING
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION.
THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY THE NFPA 101, THE REQUIREMENTS OF THE NFPA 101 OR THE DOCUMENT REFERENCED BY THE NFPA 101 SHALL BE USED EXCLUSIVELY (THIS
APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS - SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING
JURISDICTION FOR THE VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
CONCEALED SPACES AND DRAFTSTOPS:
NFPA 101 "8.6.10.1 ANY CONCEALED COMBUSTIBLE SPACE IN WHICH BUILDING MATERIALS HAVING A FLAME SPREAD INDEX GREATER THAN
CLASS A ARE EXPOSED SHALL BE DRAFT STOPPED AS FOLLOWS:
(1) EVERY EXTERIOR AND INTERIOR WALL AND PARTITION SHALL BE FIRESTOPPED AT EACH FLOOR LEVEL, AT THE STORY CEILING LEVEL AND
AT THE LEVEL OF SUPPORT FOR ROOFS
(2) EVERY UNOCCUPIED ATTIC SPACE SHALL BE DIVIDED BY DRAFTSTOPS INTO AREAS NOT TO EXCEED 3000 S.F.
(3) ANY UNCONCEALED SPACE BETWEEN THE CEILING AND THE FLOOR OR ROOF ABOVE SHALL BE DRAFTSTOPPED FOR THE FULL DEPTH OF THE SPACE ALONG THE LINE OF SUPPORT FOR THE FLOOR OR ROOF STRUCTURAL MEMBERS AND, IF NECESSARY, AT OTHER LOCATIONS TO FORM AREAS NOT TO EXCEED 1000S.F. FOR ANY SPACE BETWEEN THE CEILING AND THE FLOOR, AND 3000S.F. FOR ANY SPACE BETWEEN THE CEILING
AND THE ROOF."
INTERIOR WALL & CEILING FINISH:
NFPA 101 38.3.3.2.1 INTERIOR WALL AND CEILING FINISH MATERIAL COMPLYING WITH SECTION 10.2 SHALL BE CLASS A OR CLASS B IN EXITS AND
EXIT ACCESS CORRIDORS
NFPA 101 38.3.3.2.2 INTERIOR WALL AND CEILING FINISHES SHALL BE CLASS A, CLASS B, OR CLASS C IN AREAS OTHER THAN THOSE SPECIFIED IN 38.3.3.2.1
INTERIOR FLOOR FINISH:
NFPA 101 38.3.3.3.2 INTERIOR FLOOR FINISH IN EXIT ENCLOSURES SHALL BE CLASS I OR CLASS II
38.3.3.3.3 INTERIOR FLOOR FINISH SHALL COMPLY WITH 10.2.7.1 OR 10.2.7.2 AS APPLICABLE TABLE A.10.2.2 INTERIOR FINISH CLASSIFICATION LIMITATIONS NEW BUSINESS-FLOOR FINISH-NOT APPLICABLE
OCCUPANCY SPECIFIC CODE COMPLIANCE REVIEW
NEW HEALTH CARE OCCUPANCIES, NFPA 101 LIFE SAFETY CODE CHAPTER 18 and EXISTING HEALTH CARE OCCUPANCIES, NFPA 101 LIFE SAFETY
CODE CHAPTER 19.
Since this is considered a new construction/major renovation in an existing facility and code compliance can not be verified, the worst case code scenario must be utilized.
Occupancy Type per 18.1.1.1.5 and 19.1.1.1.5, New Health Care Occupancies and Existing Health Care Occupancies are those providing sleeping accommodation for their occupants and are occupied by persons who are mostly incapable of self-preservation.
Separation of existing facility not conforming to Chapter 19 requires a 2 hour fire barrier separation, per 18.1.1.4.1 and 19.1.1.4.1.
Permitted Means of Egress Components per section 18.2.2 and 19.2.2 include;
Doors, Stairs, Smoke proof enclosures, Horizontal Exits, Ramps, Exit Passageways, Fire Escape Ladders, Alternating treat devices, Area of Refuge.
Construction Type per Table 18.1.6.1 and 19.1.6.1;
Fully sprinklered per NFPA 13 and 14.
4 Story building or higher.
Unlimited area per floor.
Construction Type I (442), I (332), or Type II (222) with roof and supports complying with Class A ASTM E108 and NFPA 220.
Corridor, Aisles and Ramps used for required exist minimum 8'-0" clear unobstructed width, Except 44" clear unobstructed width is permitted where not used for patient housing, treatment or inpatients.
Projections 6" or less from the wall and not less than 38" above the floor are permitted, per 18.2.3.4 and 19.2.3.4.
Corridor, Aisles and Ramps used for required exit minimum 6'-0" clear unobstructed width in areas in limited care or psychiatric care facilities, per 18.2.3.5 and 19.2.3.5.
Dead End Corridors per 18.2.5.2 and 19.2.5.2, maximum length 30'-0".
Travel Distance to an Exit per 18.2.6 200'-0" and per 19.2.6 150'-0" plus 50'-0" increase for fully sprinklered building, total maximum travel distance 200'-0".
Hazardous area protection per Table 18.3.2 and 19.3.2.
Boiler and fuel fire equipment rooms, Storage rooms exceeding 100 sq ft, Soiled Linen rooms, Trash rooms require one hour rated walls per 18.3.2 and no rating require if protected by a sprinkler system per 19.3.2.
Storage rooms exceeding 50 sq ft but less than 100 sq ft do not require smoke walls.
Fire Extinguishers per 18.3.5 and 19.3.5 and NFPA 10, required to be placed no more than 75'-0" apart. Additional Extinguishers to be provided in hazardous areas such as Commercial Kitchens, Boiler and fuel fire equipment rooms, Storage rooms exceeding 100 sq ft, Soiled Linen rooms, Trash rooms.
Corridor walls in new facilities are not required to be rated but limit the passage of smoke per 18.3.6.2 with doors not requiring any rating but resist the passage of smoke. Doors do not require closers per 18.3.6.3.
Corridor walls in existing facilities are required to be 1/2" hour rating and limit the passage of smoke per 19.3.6.2 with doors having a 1/3 hour rating. Doors do not require closers per 19.3.6.3. Exceptions, section 19.3.6.2.5 and 19.3.6.3.2 eliminates the fire rating requirements for walls and doors where an automatic sprinkler system is provided.
Smoke Zone Separation per 18.3.7 and 19.3.7, subdivision of each level is required into 2 smoke zones with each zone maximum 22,500 sq ft.
Smoke Zone walls are require to be 1 hour rated walls per 18.3.7.1 and 1/2 hour rated walls per 19.3.7.1.
Doors require vision panels and 1/3 hour rating.
Cooking Facilities per 18.3.2.5 and 19.3.2.5, commercial equipment if provided shall comply with 9.2.3 and NFPA 96, domestic equipment does not need to comply.
GENERAL REQUIREMENTS: NFPA 101 LIFE SAFETY CODE.
Headroom, minimum 7'-6" with projections minimum 6'-8".
Doors, must swing in the direction of egress where numbers of occupants exceed 50.
Stair minimum width per Table 7.2.2.2.2.1.2 (B), 36" where numbers of occupants does not exceed 50, 44" where numbers of occupants exceed 50 but is less than 2000.
Stair riser maximum height 7", tread minimum with 11", maximum rise to a landing 12'-0", head room 6'-8", handrail mounting height 34", guardrail height 42".
Area of refuge to be provided on all accessible levels, 30" x 48" space to be provided for wheelchairs. Area of Refuge is permitted within adjacent Smoke Zones.
Occupant load factors per Table 7.3.1.2, Health Care Inpatient Treatment use 240 sq ft per occupant, Sleeping use 120 sq ft per occupant, Ambulatory Healthcare use 100 sq ft per occupant, 500 sq ft per occupant for storage, mechanical and electrical areas.
Waiting space occupant load factor 3 sq ft per occupant, existing for waiting areas shall be in addition to existing requirements for the occupant use space per
12.1.7.2 and 13.1.7.2.
Egress widths factor per Table 7.3.3.1, Stairway width factor 0.3" per occupant, level components 0.2" per occupant per 18.2.3.2 and 19.2.3.2.
Occupant load/Egress width required;
First Level, Health Care Occupancy, 16,177 sq ft, 162 occupants, 49" stair width, 25" horiz width.
First Level, Waiting Occupancy, 655 sq ft, 44 occupants, 13" stair width, 7" horiz width.
Overall Building, 16,832 sq ft, 206 occupants, 62" stair width, 32" horiz width.
Number of exits, 2 means of egress is required per section 7.4, 18.2.4 and 19.2.4, 2 accessible means of egress is required per section 7.5.4, 18.2.4 and 19.2.4.
Boiler, Mechanical and Electrical room maximum travel distance 100'-0" per 7.12.1 (1).
Vertical enclosures per section Table 8.3.4.2 where required, Elevator hoist way 2 hour rated walls with 1 1/2 hour rated doors, Elevator lobbies 1 hour rated walls with 1 hour rated doors, Vertical shafts 2 hour rated walls with 1 1/2 hour rated doors, Corridors 1/2 hour rated walls with 1/3 hour rated doors.
GENERAL REQUIREMENTS: NFPA 220.
Fire Resistive Rating per Table 4.1.1 based on Construction Type I (442);
Exterior Baring walls, 4 hour fire rating, 4 hour fire rating if supporting a roof only.
Columns, 4 hour fire…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .