36E77619R0084-005.pdf
PDF 20 MB Posted
- Attached to
- Construct Parking Garage Omaha Federal contract opportunity
- Solicitation number
- 36E77619R0084
About this file
36E77619R0084 Attachment 4 Drawings Omaha 1 of 3.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36E77619C0075-000.docx | DOCX document | |
| 36E77619R0084-0004001.pdf | ||
| 36E77619R0084-0004002.pdf | ||
| 36E77619R0084-0004000.docx | DOCX document | |
| 36E77619R0084-0003000.docx | DOCX document | |
| 36E77619R0084-0003001.pdf | ||
| 36E77619R0084-0003003.pdf | ||
| 36E77619R0084-0003005.pdf | ||
| 36E77619R0084-0003002.pdf | ||
| 36E77619R0084-0003004.pdf | ||
| 36E77619R0084-0002000.docx | DOCX document | |
| 36E77619R0084-0001000.docx | DOCX document | |
| 36E77619R0084-002.pdf | ||
| 36E77619R0084-004.pdf | ||
| 36E77619R0084-010.pdf | ||
| 36E77619R0084-001.docx | DOCX document | |
| 36E77619R0084-007.pdf | ||
| 36E77619R0084-009.docx | DOCX document | |
| 36E77619R0084-006.pdf | ||
| 36E77619R0084-008.docx | DOCX document | |
| 36E77619R0084-003.pdf | ||
| 36E77619R0084-000.docx | DOCX document |
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GOVERNING CODES:
ICC, International Building Code, 2018 edition (IBC) NFPA 101, Life Safety Code, 18th edition, 2018 (LSC) NFPA 10, Standard for Portable Fire Extinguishers, 18th edition, 2017 NFPA 14, Standard for the Installation of Standpipe and Hose System, 2016 edition NFPA 24, Standard for the Installation of Private Fire Service Mains and their Appurtenance, 2016 edition NFPA 72, National Fire Alarm Code, 2016 edition NFPA 70, National Electric Code, 17th edition, 2017 NFPA 80, Standard for Fire Doors and Other Opening Protectives, 16th edition, 2015 NFPA 88A, Standard for Parking Structures, 2015 edition NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating
Systems, 2018 edition NFPA 220, Standard Types of Building Construction, 2018 edition NFPA 291, Recommended Practice for Fire Flow Testing and Marking of
Hydrants, 2016 edition ASTM E2072-04, Specification for Photoluminescent (Phosphorescent) Safety
Markings, 2014 edition
International Plumbing Code 2015 edition ASHRAE 90.1 IP -2016 edition
ASHRAE 62.1 – 2016
ICC A117.1 Standard on Accessible & Usable Buildings and Facilities 2017 2010 ADA Standards for Accessible Design
ASCE-07-10
ACI 318-14
ACI 530-13
AISC 341-10
AISC 360 2016 edition PCI MNL 120, Design Handbook 7th edition, 2012
VA Parking Design Manual & Demand Model, April 2013 VA Barrier Free Design Guide Architectural Electrical
HVAC
Plumbing Site and Landscape Auto Transport Interior Design Structural Sanitary Fire Protection, Seventh Edition December 2015 Facilities Physical Security Design Manual: Life-Safety Protected Sustainability Guidelines
VA DESIGN MANUALS:
G.MEANS OF EGRESS
Means of egress shall be in compliance with LSC and as modified by NFPA 88A. Egress requirements are based upon a non-sprinklered building. Exits must be so located on each story such that the maximum length of exit access travel, measured from the most remote point within a story along the natural and unobstructed path of egress travel to an exterior exit door at the level of exit discharge, an entrance to a vertical exit enclosure, an exit passageway, a horizontal exit, an exterior exit stairway or an exterior exit ramp, may not exceed the distances allowed by the Code. Egress requirements are outlined below.
1. Maximum travel distance: open parking garage – 300 feet (LSC Table 42.8.2.6.1)
2. Common path of travel:50 feet (LSC 42.8.2.5.1)
3. Dead ends: 50 feet (LSC 42.8.2.5.2)
4. Number of exits: At least two exits shall be provided from every floor/tier. In certain conditions ramps may be substituted for an egress stair. (LSC 42.8.2.4)
5. Egress Width Factor: LSC Table 7.3.3.1 requires a minimum egress width of 0.2 in per occupant for doors, ramps, and corridors and a minimum egress width of 0.3 in per occupant for stairs.
6. Occupant Load factor: LSC Table 7.3.1.2 requires an Occupant load factor reflecting the “maximum probable number of occupants present at any time” be applied to storage use areas in storage occupancies. Parking garages are classified by chapter 42 of the LSC as storage type occupancies. IBC Table 1004.1.2 requires an occupant load factor of 200 for parking garages.
7. Remoteness of exits: Where two or more exits or exit access doorways are required from any portion of the exit access, at least two of the exit doors or exit access doorways must be placed a distance apart equal to not less than one-half of the length of the maximum overall diagonal dimension of the building or area to be served measured in a straight line between exit doors or exit access doorways.
8. Stairs Design (per the LSC 7.2.2):
Maximum Riser Height: 7 inches
Minimum Tread Length: 11 inches Minimum Stair Width: 36 inches
Guard: 42 inches (Required where elevation change exceeds 30 inches. Design shall prevent the passage of a 4 inch Sphere.)
Handrail: 30-38 inches Minimum Clearance: 6 feet 8 inches (Measured vertically from nose of tread.)
Signage: Required at each floor level per LSC 7.2.2.5.4
9. Ramp Design: (per the LSC 7.2.5):
Maximum Slope: 1/12 Guard: 42 inches (Required where elevation change exceeds 30 inches. Design shall prevent the passage of a 4 inch Sphere.)
4 inch curbs required for drop off edge of ramp Handrail: 30-38 inches (required for ramps with more than a 6 inch rise.
10. Areas Of Refuge: Not required in open parking garages (LSC 42.8.2.2.9.2)
H. EMERGENCY ELEVATOR OPERATION
Elevator will have a Smoke detector, located in its respective lobby, on each floor level where the lobby is enclosed. A heat detector is permitted where the lobby is open to the environment. Upon activation of a lobby heat detector or machine room smoke detector, the elevators served by that lobby or machine room will be recalled to the main level of the building. In the event that the alarm is on this designated level, the elevators will be recalled to an alternate level.
After returning to the appropriate level, the elevators will stop, the doors will open, and the elevators will be rendered inoperable without the use of the fireman's key or until such time that they are manually reset to the normal operating mode. This mode of operation is provided for fire department use to allow for access to all levels served by the elevators.
I. AUTOMATIC SPRINKLER SYSTEM
Not required in open parking garages (LSC 42.8.3.5) (NFPA 88A 6.4.4)
J. STANDPIPES
Class I Standpipes are not required in open parking garages not exceeding 50 feet in height. This building exceeds 50 feet in height.
Standpipes will be provided PER NFPA 88A 6.5.1 and NFPA 14
A Class 1 standpipe system will be provided as required by NFPA 88A Standpipe systems will be installed throughout the garage because the building will exceed 50 feet in height. The intent of providing standpipes is to assist the fire department with interior operations in the event of an emergency. Standpipes will be located within each stair at the intermediate landings between floors, at the highest floor landing of the stair with access to grade. Additionally, supplemental standpipe outlets will be provided where travel distance from the exit stairways exceeds the reach of 200 feet at locations approved by the local fire department.
The water supply for the fire department outlets is expected to be designed as a manual dry standpipe system.
1. The piping system will be designed in accordance with the requirements of NFPA 14.
2. All standpipe hose outlets will be 2-1/2-in with a 1-1/2-in reducer, cap and chain. Threads and valves will be compatible with the local fire department requirements. As permitted by the Code, hose and nozzle equipment will not be installed.
3. The fire department connection will be per local fire department requirements.
Maximum spacing between hydrants shall not exceed 300 ft. Locate hydrants such that every portion of the exterior of every building shall be within 300 ft of a hydrant, with consideration given to accessibility and obstructions. Nominal distance between a fire hydrant and the building fire department connection shall be 50 ft..
K. PORTABLE FIRE EXTINGUISHERS
Portable fire extinguishers will be provided throughout the garages as required by IFC section 906.1 and spaced in accordance with NFPA 10, 2016 edition.
L. FIRE ALARM SYSTEM
Not required in open parking garages (IBC 907.2, LSC 42.8.3.4.1.2) (NFPA 88A 6.3.3)
A. OCCUPANCY CLASSIFICATION
The parking garage is classified by IBC as low-hazard storage facilities, a Group S-2 Occupancy, and as an ordinary hazard by NFPA 101 (42.8.1.5).
The parking garage is considered an open, ramp type parking structure openings shall comply with the following:
1. Open Parking Structure: A parking structure that meets the requirements of NFPA 88A Section 4.7.1.
i. Each parking level shall have wall openings to the atmosphere for an area of not less than 1.4 square feet for each linear foot of the exterior perimeter.
ii. Opening shall be distributed over a minimum of 40% of the building perimeter or uniformly over two opposing sides.
iii. Interior wall lines and columns shall be at least 20% open, with openings distributed to provide ventilation.
2. This parking garage is classified as a Ramp Type Parking Structure: A parking Structure that utilizes sloped ramps for vertical vehicle circulation.
B. CONSTRUCTION CLASSIFICATION
The parking garage is to be constructed in accordance with the provisions of NFPA 88A as defined in NFPA 220. Construction type for a building exceeding 25 feet in height shall be Type I, Type II(222) or Type II(111) . An open parking garage of these construction types may be unlimited in height and area.
The Parking Garage has four levels and is classified as an open parking structure. The construction classification is Type IIA, which is a permitted type, based upon the occupancy and area of the building.
Primary structural elements of. Primary structural elements of Type II(111) buildings will be 1-hour rated. Primary structural elements supporting a roof only will be 1-hour rated, and all floor construction will have a fire resistance rating of 1-hours.
Primary structural members are considered to be bearing walls, columns, and the girders, beams, trusses and spandrels having direct connections to columns and bracing members designed to carry gravity loads. The members of floor or roof panels which have no connection to the columns and do not carry a gravity load are considered secondary members and are not part of the structural frame of a building.
CODE ANALYSIS
C. FIRE RESISTANCE RATED SEPARATIONS
The garage will be designed as nonseparated mixed uses. Incidental uses are not anticipated, so no fire rated separation is required between occupancies. Interior building elements that require fire resistance ratings are listed below:
BUILDING ELEMENT FIRE RESISTANCE RATING CODE REFERENCE
Exit Stair Enclosures Open (a,b) NFPA 88A, 4.1.5
Ramps Open (a,b) NFPA 101, 42.8.3.1.1
Elevator Hoistways Unprotected NFPA 88A, 5.4.8
NFPA 101, 42.8.3.1.2
Mechanical Exhaust and Supply duct systems where the duct system isolated within the garage IBC 708.2 and serves only the garage 0 Excep. 15
Other shafts which connect 2 or more stories 2 (a) NFPA 101, 42.8.3.11
Elevator machine rooms 2 IBC 3006.4
NFPA 101, 7.15.7.1
Emergency genorator (if provided) 2 NFPA 70
a. Supporting structural members (located within one structural bay) must have the same fire resistance rating. The fire resistance rating must be carried through all structural members; extending to the foundation. In addition, the shaft construction must maintain the same fire rating as the floor construction.
b. Where nonrated walls or unprotected openings enclose the exterior of the stairway and the walls or openings are exposed by other parts of the building at an angle of less than 180 degrees, the building exterior walls within 3.048 m (10 ft) horizontally of a nonrated wall or unprotected opening must have a fire resistance rating of not less than 1-hour. Openings within such exterior walls must be protected by opening protectives having a fire protection rating of not less than ¾-hour. This construction must extend vertically from the ground to a point 3.048 m (10 ft) above the topmost landing of the stairway or to the roof line, whichever is lower.
Mechanical equipment and general storage rooms incidental to the use of the building are not required to be separated by an occupancy separation.
Special hazard rooms such as furnace/boiler rooms and electrical switchgear rooms shall be separated per NFPA 70 and potentially IBC Table 508.4.
Cashier and attendant booths is not required to be separated. NFPA 88A 5.2.4.
The storage, security and IT rooms do not have a total area exceeding 3,000 s.f. therefore shall be separated by partitions built to resist the passage of smoke. NFPA 88A 5.2.4.
Fire barriers will extend from the top of the floor below to the underside of the floor or roof deck above. The openings and penetrations in required exit enclosures will be protected with self-closing or automatic-closing opening protectives. Openings in fire resistance rated walls will be protected in accordance with the following:
COMPONENT WALLS AND PARTITIONS FIRE DOOR ASSEMBLIES
(HR) IBC 709 (MIN) IBC 715
Elvivator Hoistways, Elevator Machine Rooms 2 90
Vertcal Shafts (including exit stairways required to be enclosed) 2 90
1 45 Bire Barriers 2 90
3 180
Piping, conduit, and wire penetrations of fire rated construction will be protected by materials or systems of the same hourly rating listed by Underwriters Laboratories (UL), Factory Mutual (FM), or a National Recognized Testing Laboratory (NRTL). Duct, air transfer openings, and other penetrations through floors, shaft enclosures and other fire rated construction will be protected in accordance with the IBC.
D. BUILDING PLACEMENT
For parking garages, building separation and requirements for rated exterior walls and openings shall comply with the requirements of NFPA 88A. This code requires the exterior walls of buildings to be protected from one another based on the fire separation distance between buildings, or to a lot line. Fire separation distance is defined as the distance measured from the face of a building to one of the following three points:
1. The closest interior lot line;
2. To the centerline of a street, an alley or public way, or;
3. To an imaginary line between two buildings on the property.
No fire rated separation is required where the parking structure is separated by 10 feet. NFPA 88A 5.2.2
E. INTERIOR FINISH
Interior wall and ceiling finish to be designed in accordance with the NFPA 101, 42.8.3.3.3.
Class A, B and C finish is permitted for interior walls and ceilings in rooms, and corridors. Class A or B finish is permitted for exits.
Per the IBC Section 406.2.5 all floor surfaces shall be of concrete or other similar non-combustible and non-absorbent materials.
Floor Finish shall not be less than Class II
F. EGRESS LIGHTING AND EXIT SIGNAGE
Emergency egress lighting will be provided throughout the common portions of the means of egress in accordance with The Life Safety Code section 42.8.2.8, 42.8.2.9 and 42.8.2.10 These areas include drive lanes, corridors, and exit access spaces within areas requiring two (2) or more means of egress, the lobby/entrance areas, exit stairs, and the exit discharge areas (including exterior locations until the public way).
Each required exit will be identified with an exit sign, including exit access, and within areas requiring multiple exits. Directional exit signs will also be provided to direct occupants toward the closest exit so that no occupant is more than 100 feet from an exit sign.
The egress lighting and exit signs will be provided with a secondary source of power in the event that the primary power source is disrupted. The secondary power source will consist of either internal batteries or a connection to an emergency power system.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST, SUITE 200
INDIANAPOLIS, IN 46202
C te m p
\1
V A
O m a h a b ra d .w ill ia m s J Y
V F
.r v t
/9
/2
:4
:3
P M
GI002
CODE ANALYSIS
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 649-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
05/10/2019 KS BW
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Sheet 2 of 94Revisions: Date:
UP
UP
DIAGONAL DISTANCE = 332'-10"
EXIT SEPARATION = 293'-9"
EXIT
1 2 3 4 5 6 7 8 9
A
B
C
EXIT
300 SF
S
150 SF
S
145 SF
S
296 SF
S
36718 SF
200184
S
240 SF
S
PATH B
PATH A
92 PEOPLE
92 PEOPLE
89 SF
S
DOOR CAPACITY:
360 PERSONS
1 2 3 4 5 6 7 8 9
A
B
C
DIAGONAL DISTANCE = 332'-10"
EXIT SEPARATION = 293'-9"
37778 SF
200189
S
232 SF
S
95 PEOPLE
94 PEOPLE
PATH D
PATH C
1 2 3 4 5 6 7 8 9
A
B
C
DIAGONAL DISTANCE = 332'-10"
EXIT SEPARATION = 293'-9"
37751 SF
200189
S
236 SF
S
EXIT
EXIT
95 PEOPLE
94 PEOPLE
PATH E
PATH F
LIFE SAFETY PLAN LEGEND
TOTAL OCCUPANCY
FE
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER CABINET
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
SMOKE PARTITION
B
1500 SF
2 HR. - FIRE SEPARATION
EXIT DISTANCE
ISOMETRIC KEYPLAN
LEVEL 2
+11'-4"
LEVEL 1
0'-0"
LEVEL 3
+22'-8"
LEVEL 4
+34'-0"
LEVEL 5
+45'-4"
ALL STAIRS 4'-0" WIDE
48"/0.3" = 160 CAPACITY
ALL DOORS 36" U.N.O
36" DOOR / 0.2" PER
PERSON = 180 PERSONS
LIFE SAFETY CALCULATIONS
1 2 3 4 5 6 7 8 9
A
B
C
LOBBY
94 PEOPLE
93 PEOPLE
DIAGONAL DISTANCE = 332'-10"
EXIT SEPARATION = 293'-9"
PATH H
PATH G
37390 SF
200187
S
EXIT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST, SUITE 200
INDIANAPOLIS, IN 46202
C te m p
\1
V A
O m a h a b ra d .w ill ia m s J Y
V F
.r v t
/9
/2
:4
:3
P M
GI003
LIFE SAFETY PLANS
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 649-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
05/10/2019 KS BW
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Sheet 3 of 94
SCALE: 3/64" = 1'-0"GI003
1 LEVEL 1 LIFE SAFETY PLAN
SCALE: 3/64" = 1'-0"GI003
2 LEVEL 2 LIFE SAFETY PLAN
SCALE: 3/64" = 1'-0"GI003
3 LEVEL 3 LIFE SAFETY PLAN
LIFE SAFETY OCCUPANCY
AREA SF OCC OCC FACTOR # OF OCC
LEVEL 1
ELECTRICAL 296 SF S 200 2
STORAGE 300 SF S 200 2
OIT 150 SF S 200 1
SECURITY 145 SF S 200 1
PARKING 36718 SF S 200 184
LOBBY 240 SF S 200 2
ELEV. CTRL 89 SF S 200 1
37938 SF 193
LEVEL 2
PARKING 37778 SF S 200 189
LOBBY 232 SF S 200 2
38011 SF 191
LEVEL 3
PARKING 37751 SF S 200 189
LOBBY 236 SF S 200 2
37988 SF 191
LEVEL 4
PARKING 37390 SF S 200 187
37390 SF 187
LEVEL 5 / ROOF
PARKING 18519 SF S 200 93
18519 SF 93
169845 SF 855
EXIT
FIRST FLOOR EXIT DISTANCES
Type Comments Path of Egress
01 Start PATH A 25' - 0"
02 Middle PATH A 117' - 0"
02 Middle PATH A 28' - 10"
03 End PATH A 46' - 10"
PATH A 217' - 8"
01 Start PATH B 27' - 3"
02 Middle PATH B 151' - 8"
03 End PATH B 33' - 11"
PATH B 212' - 10"
LEVEL 2 EXIT DISTANCES
Type Comments Path of Egress
01 Start PATH C 25' - 0"
02 Middle PATH C 128' - 8"
02 Middle PATH C 28' - 0"
02 Middle PATH C 30' - 10"
02 Middle PATH C 13' - 0"
02 Middle PATH C 3' - 0"
PATH C 228' - 6"
01 Start PATH D 25' - 0"
02 Middle PATH D 148' - 0"
03 End PATH D 26' - 4"
PATH D 199' - 4"
LEVEL 3 EXIT DISTANCES
Type Comments Path of Egress
01 Start PATH E 25' - 0"
02 Middle PATH E 13' - 0"
02 Middle PATH E 38' - 2"
02 Middle PATH E 29' - 0"
02 Middle PATH E 124' - 0"
03 End PATH E 3' - 6"
PATH E 232' - 9"
01 Start PATH F 25' - 0"
02 Middle PATH F 151' - 6"
03 End PATH F 25' - 5"
PATH F 201' - 11"
N N
N
SCALE: 3/64" = 1'-0"GI003
5 LEVEL 4 LIFE SAFETY PLAN
N
LEVEL 4 EXIT DISTANCES
Type Comments Path of Egress
01 Start PATH G 23' - 6"
02 Middle PATH G 125' - 0"
02 Middle PATH G 29' - 7"
02 Middle PATH G 40' - 10"
02 Middle PATH G 13' - 1"
PATH G 231' - 11"
01 Start PATH H 25' - 0"
02 Middle PATH H 141' - 0"
03 End PATH H 24' - 6"
PATH H 190' - 6"
GROSS BUILDING AREA
FLOOR SF
LEVEL 1 37938 SF
LEVEL 2 38011 SF
LEVEL 3 37988 SF
LEVEL 4 37390 SF
LEVEL 5 / ROOF 18519 SF
TOTAL GSF 169845 SF
Revisions: Date:
1 2 3 4 5 6 7 8 9
A
B
C
PATH K
18519 SF
20093
S
DIAGONAL DISTANCE = 332'-10"
EXIT SEPARATION = 308''-7"
EXIT
LIFE SAFETY PLAN LEGEND
TOTAL OCCUPANCY
FE
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER CABINET
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
SMOKE PARTITION
B
1500 SF
2 HR. - FIRE SEPARATION
EXIT DISTANCE
ISOMETRIC KEYPLAN
LEVEL 2
+11'-4"
LEVEL 1
0'-0"
LEVEL 3
+22'-8"
LEVEL 4
+34'-0"
LEVEL 5
+45'-4"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST, SUITE 200
INDIANAPOLIS, IN 46202
C te m p
\1
V A
O m a h a b ra d .w ill ia m s J Y
V F
.r v t
/9
/2
:4
:3
P M
GI004
LIFE SAFETY PLANS
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 649-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
05/10/2019 KS BW
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Sheet 4 of 94
N
SCALE: 3/64" = 1'-0"GI004
1 LEVEL 5 LIFE SAFETY PLAN
LEVEL 5 EXIT DISTANCES
Type Comments Path of Egress
01 Start PATH K 14' - 2"
02 Middle PATH K 113' - 3"
03 End PATH K 11' - 0"
PATH K 138' - 5"
LIFE SAFETY OCCUPANCY
AREA SF OCC OCC FACTOR # OF OCC
LEVEL 1
ELECTRICAL 296 SF S 200 2
STORAGE 300 SF S 200 2
OIT 150 SF S 200 1
SECURITY 145 SF S 200 1
PARKING 36718 SF S 200 184
LOBBY 240 SF S 200 2
ELEV. CTRL 89 SF S 200 1
37938 SF 193
LEVEL 2
PARKING 37778 SF S 200 189
LOBBY 232 SF S 200 2
38011 SF 191
LEVEL 3
PARKING 37751 SF S 200 189
LOBBY 236 SF S 200 2
37988 SF 191
LEVEL 4
PARKING 37390 SF S 200 187
37390 SF 187
LEVEL 5 / ROOF
PARKING 18519 SF S 200 93
18519 SF 93
169845 SF 855
GROSS BUILDING AREA
FLOOR SF
LEVEL 1 37938 SF
LEVEL 2 38011 SF
LEVEL 3 37988 SF
LEVEL 4 37390 SF
LEVEL 5 / ROOF 18519 SF
TOTAL GSF 169845 SF
B
C
ALTERNATE D
N
1 2 3 4 5 6 7 8 9
A
B
C
ALTERNATE D
ALTERNATE E
1 2 3 4 5 6 7 8 9
A
B
C
ALTERNATE D
ALTERNATE F
ALTERNATE E
BID ALTERNATE DEDUCTS
ALT
A.
B.
C.
D.
E.
F.
DESCRIPTION
DEDUCT SECURITY CAMERAS
DEDUCT FALL DETERRANT AT SECOND LEVEL
DEDUCT ELEVATOR #2
DEDUCT DECK AREA 2 FROM NORTH GRID 7 TO SOUTH OF
GRID 7. REDUCE STAIR TOWER 2 ONE LEVEL.
DEDUCT DECK AREA 3 FROM GRID 7 TO GRID 3
G.
DEDUCT DECK AREA 4 SOUTH GRID 3 TO NORTH GRID 3.
REDUCE STAIR TOWER 1 ONE LEVEL.
H. DEDUCT DECK AREA 5 FROM GRID 3 TO GRID 7
DEDUCT DECK AREA 1 FROM TOP TO GRID 7
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST, SUITE 200
INDIANAPOLIS, IN 46202
C te m p
\1
V A
O m a h a b ra d .w ill ia m s J Y
V F
.r v t
/9
/2
:4
:3
P M
GI005
DEDUCT ALTERNATES
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 649-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
05/10/2019 KS BW
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Sheet 5 of 94
SCALE: 1" = 20'-0"GI005
1 LEVEL 5 PLAN ALTERNATE 1
SCALE: 1" = 20'-0"GI005
2 LEVEL 5 PLAN ALTERNATE 2
SCALE: 1" = 20'-0"GI005
4 LEVEL 5 PLAN ALTERNATE 3
N N
A
B
C
ALTERNATE G
ALTERNATE F
1 2 3 4 5 6 7 8 9
A
B
C
ALTERNATE F
ALTERNATE G
ALTERNATE H
BID ALTERNATE DEDUCTS
ALT
A.
B.
C.
D.
E.
F.
DESCRIPTION
DEDUCT SECURITY CAMERAS
DEDUCT FALL DETERRANT AT SECOND LEVEL
DEDUCT ELEVATOR #2
DEDUCT DECK AREA 2 FROM NORTH GRID 7 TO SOUTH OF
GRID 7. REDUCE STAIR TOWER 2 ONE LEVEL.
DEDUCT DECK AREA 3 FROM GRID 7 TO GRID 3
G.
DEDUCT DECK AREA 4 SOUTH GRID 3 TO NORTH GRID 3.
REDUCE STAIR TOWER 1 ONE LEVEL.
H. DEDUCT DECK AREA 5 FROM GRID 3 TO GRID 7
DEDUCT DECK AREA 1 FROM TOP TO GRID 7
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST, SUITE 200
INDIANAPOLIS, IN 46202
C te m p
\1
V A
O m a h a b ra d .w ill ia m s J Y
V F
.r v t
/9
/2
:4
:3
P M
GI006
DEDUCT ALTERNATES
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 649-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
05/10/2019 KS BW
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Sheet 6 of 94
SCALE: 1" = 20'-0"GI006
1 LEVEL 4 PLAN ALTERNATE 4
SCALE: 1" = 20'-0"GI006
2 LEVEL 4 PLAN ALTERNATE 5
N N
VA FORM 08 - 6231
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLANK ROAD
ELM GROVE, WI 53122
(262) 641-0746
Revisions: Date:
100% CONSTRUCTION
DOCUMENTATION
NON-SPRINKLERED
Sheet 5 of 78
636-116OMAHA VAMC - NEW PARKING
GARAGE
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
08/21/2018 KS BW
VF101
TOPOGRAPHIC AND BOUNDARY
SURVEY
- CHAIN LINK FENCE
- ELEC. MANHOLE
- STORM SEWER MANHOLE
- PROPERTY LINE
- CORNERS SET (#5 Rebar w/Cap ???)
- FIRE HYDRANT
- TELEPHONE PEDESTAL
- SIGN
- LIGHT POLE
- WATER MANHOLE
- CONIFEROUS TREE w/trunk size
- DECIDUOUS TREE w/trunk size
- ELECTRICAL TRANSFORMER
LEGEND
- WATER VALVE
- SANITARY SEWER MANHOLE
- CABLE TV PEDESTAL
- POWER POLE
- TELE./COMMUNICATIONS MANHOLE
- DECORATIVE LIGHT POLE
- SURVEY CONTROL POINT
- STORM GRATE INLET
- BOARD FENCE
- SPRINKLER VALVE
- GAS LINE
- WATER LINE
- CORNERS FOUND (as noted)
- SANITARY SEWER LINE
- STORM SEWER LINE
- OVERHEAD TELEPHONE LINE
- UNDERGROUND TELEPHONE LINE
- OVERHEAD POWER LINE
- UNDERGROUND POWER LINE
- SHRUB
- CLEAN-OUT
- BOLLARD
NOTE: SOME UTILITIES WERE LOCATED BY
PLANS THAT WERE PROVIDED BY:
NAGEL ARCHITECTS AND ENGINEERS.
SOME UTILITIES WERE LOCATED BY:
GROUND CONTROL LOCATING SERVICES LLC
THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED PER A ONE-CALL LOCATE TICKET #173390246 AND SHOWN FROM OBSERVED FIELD SURVEY INFORMATION AND RECORD LOCATIONS PROVIDED BY THOSE COMPANIES RESPONDING TO SAID LOCATE TICKET. SCHEMMER MAKES NO GUARANTEE THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. SCHEMMER GIVES NO WARRANTY, EXPRESSED OR IMPLIED, AS TO THE ACCURACY OF THE LOCATION OF THE UNDERGROUND UTILITIES. NO RESPONSIBILITY OR LIABILITY IS ASSUMED BY SCHEMMER FOR ANY DAMAGE TO UNDERGROUND UTILITIES WHICH MAY OCCUR FROM THE USE OF THE UTILITY INFORMATION PROVIDED HEREON. CONTACT "ONE-CALL" (1-800-331-5666) PRIOR TO ANY EXCAVATION ON THIS SITE.
UTILITY NOTE:
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
905 N. CANPITOL AVE, SUITE 100
INDIANAPOLIS, IN 46204
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163 4101 WOOLWORTH AVE
05/10/2019
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
N
AL
E
G
I
N
E
E
R
S
T
A
T
O
F
N
E
B
R
A
S
K
A
CC001
GENERAL CIVIL NOTES
Sheet 8 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CC002
PHASING PLAN
0 4020
Sheet 9 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CD101
DEMOLITION PLAN
0 4020
Sheet 10 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CS101
SITE PLAN
0 4020
Sheet 11 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CS501
SITE DETAILS
Sheet 12 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CS502
SITE DETAILS
STOPSTOP
ONLY
DO NOT
ENTER
Sheet 13 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CG101
GRADING PLAN
0 4020
Sheet 14 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CU101
UTILITY PLAN
0 4020
Sheet 15 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CU102
STORM PROFILE
0 4020
Sheet 16 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CU501
UTILITY DETAILS
Sheet 17 of 94
Internal
Baffles
Riser
Bedding
Undisturbed Soil
Backfill
Grade (Rim)
Rim elevations to match finished grade.
Manhole Frame and
Cover by Manufacturer
Pipe coupling by
Contractor. 12" long Stub-out by
Manufacturer.
A
A
Outlet
Inlet
Internal Baffles
Octagonal Base Plate
Swirl Inlet/Outlet
Invert Per CU101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
UTILITY DETAILS
CU502
Sheet 18 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
CJ101
EROSION
CONTROL PLAN
0 4020
Sheet 19 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA ST.
INDIANAPOLIS, IN 46202
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLAN ROAD
ELM GROVE, WI 53122
(262) 641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
N/A
05/10/2019 HFSP
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
Revisions: Date:
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
S
T
A
N
E
B
R
A
S
K
A
EROSION CONTROL
DETAILS
CJ501
Sheet 20 of 94
MISCELLANEOUS SYMBOLS
NORTH ARROW
GRIDLINES
EARTH
SECTION NUMBER
SHEET NUMBER
S101
S101
CALLOUT NUMBER
SHEET NUMBER
A
ELEVATION REFERENCE
LIMIT OF EXTENT
CONTINUOUS EXTENT
F ## COLUMN FOOTING NOTATION
GB ## GRADE BEAM NOTATION
P ## PIER NOTATION
B ## CONCRETE BEAM NOTATION
PC ## PILE CAP NOTATION
WF ## WALL FOOTING NOTATION
SHEAR WALL NOTATIONSW ##
BW ## BEARING WALL NOTATION
GRAVEL
Name
Elevation
TF ## TRENCH FOOTING NOTATION
FLOOR DRAIN
FD
N
CONCRETE WASH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N PENNSYLVANIA ST
INDIANAPOLIS, IN 46202
5/10/2019
C U s e rs
\b th o m a s \D o c u m e n ts
\1 .1
S
V A
O m a h a v b ill th o m s .r v t
/8
/2
:5 :3
P
M
SI001
ABBREVIATIONS AND SYMBOLS
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLANK ROAD, SUITE 200
ELM GROVE, WI 53122
(262)-641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
TBD
05/10/2019 LKL WJT
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
JST JOIST
JT JOINT
KB KNEE BRACE
KIP, K 1,000 POUNDS
KO KNOCK-OUT
KSI KIPS PER SQUARE INCH
L ANGLE OR LENGTH
LAB LABRATORY
LB POUND
LF LINEAL FOOT
LIN LINEAL, LINEAR
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONGIT LONGITUDINAL
LP LOW POINT
LSLT LONG SLOTTED HOLE
LTWT LIGHT WEIGHT
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MC MISCELLANEOUS CHANNEL
MECH MECHANICAL
MEMB MEMBRANE
MEP MECHANICAL/ ELECTRICAL/ PLUMBING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MULT MULTIPLE
N/A NOT APPLICABLE
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFD OVERFLOW DRAIN
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPPHD OPPOSITE HAND
ORIG ORIGINAL
OVS OVERSIZED HOLE
P PIER
PC PIER CAP OR PRECAST
PERIM PERIMETER
PERM PERMANENT
PERP PERPENDICULAR
PJP PARTIAL JOINT PENETRATION
PL PLATE
PLF POUNDS PER LINEAL FOOT
PLYWD PLYWOOD
PREFAB PREFABRICATED
PREL PRELIMINARY
PREP PREPARATION, PREPARE
PROJ PROJECTION
PS PRESTRESSED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT POST-TENSIONED
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCEMENT, REINFORCE
REQD REQUIRED
RO ROUGH OPENING
SCH SCHEDULE
SECT SECTION
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SL SLOPE
SL-DN SLOPE DOWN
SL-UP SLOPE UP
SOG SLAB-ON-GRADE
SP SHEET PILING
SPA SPACES, SPACE
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
SSLT SHORT SLOTTED HOLE
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUC STRUCTURAL
SYM SYMMETRICAL
T & B TOP AND BOTTOM
T/ TOP OF
T/GB TOP OF GRADE BEAM
TBS MECHANICAL TENSION BUTT SPLICE
TEMP TEMPERATURE
TF TRENCH FOOTING
THRU THROUGH
TRANS TRANSVERSE
TYP TYPICAL
UL UNDERWRITERS' LABORATORY INC.
UNO UNLESS NOTED OTHERWISE
UT ULTRA-SONIC TEST
VERT VERTICAL
W WIDE FLANGE
W/ WITH
W/O WITHOUT
WD WOOD
WF WALL FOOTING
WP WORK POINT
WWF WELDED WIRE FABRIC
A/E ARCHITECT/ENGINEER
ACI AMERICAN CONCRETE INSTITUTE
ACP AUGER CAST PILE
ADDL ADDITIONAL
ADJ ADJACENT
AGGR AGGREGATE
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
AR ANCHOR ROD
ARCH ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AWS AMERICAN WELDING SOCIETY
B/ BOTTOM OF
BAL BALANCE
BD BOARD
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOTT BOTTOM
BRG BEARING
BRKT BRACKET
BTWN BETWEEN
C STANDARD CHANNEL
CANT CANTILEVER
CC CENTER TO CENTER
CF COLD FORMED
CG CENTER OF GRAVITY
CIP CAST-IN-PLACE
CJ CONTROL JOINT OR CONSTRUCTION JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE
CLR CLEARANCE, CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CTR CENTER
CTRD CENTERED
CU FT CUBIC FEET
CU IN CUBIC INCH
CYD CUBIC YARD
CW CONCRETE WALL
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION, DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIAPH DIAPHRAGM
DIM DIMENSION
DN DOWN
DO DITTO
DP DRILLED PIER OR DEEP
DWG DRAWING
DWL DOWELS
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL, ELEV ELEVATION
ELEC ELECTRICAL
ENCL ENCLOSURE
ENGR ENGINEER
EOD EDGE OF DECK
EOJ EDGE OF JOIST
EOS EDGE OF SLAB
EQ EQUAL
EQPT EQUIPMENT
ES EACH SIDE
EW EACH WAY
EX EXISTING
EXP EXPANSION
EXT EXTERIOR
FAB FROM ADJACENT BEAM
FD FLOOR DRAIN
FDN FOUNDATION
FIN FINISH
FLG FLANGE
FLR FLOOR
FS FOOTING STEP
FT FEET
FTG FOOTING
FTGD FOOTING DRAIN
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GRND GROUND
GT GIRDER TRUSS
HAS, HS HEADED ANCHOR STUD
HK HOOK
HORIZ HORIZONTAL
HP HIGH POINT
HS HOLLOW STRUCTURAL SECTION
HT HIP TRUSS
HVAC HEATING, VENTILATION, AIR CONDITIONING
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCH
INCL INCLUDE
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
J/BRG JOIST BEARING
STRUCTURAL ABBREVIATIONS
STRUCTURAL SHEET LIST
SI001 ABBREVIATIONS AND SYMBOLS
SI002 STRUCTURAL GENERAL NOTES
SI003 LOAD MAPS
SB101 FOUNDATION PLAN
SB401 ENLARGED FOUNDATION PLANS
SB501 FOUNDATION SECTIONS AND DETAILS
SB502 FOUNDATION SECTIONS AND DETAILS
SB503 FOUNDATION SCHEDULES AND DETAILS
SF101 SLAB-ON-GRADE PLAN
SF102 SECOND FLOOR FRAMING PLAN
SF103 THIRD FLOOR FRAMING PLAN
SF104 FOURTH FLOOR FRAMING PLAN
SF105 FIFTH FLOOR FRAMING PLAN
SF201 BUILDING ELEVATIONS
SF202 CAST IN PLACE WALL ELEVATIONS
SF203 SHEAR WALL ELEVATIONS AND SCHEDULES
SF204 PRECAST WALL ELEVATIONS
SF401 ENLARGED STAIR/ELEVATOR PLANS
SF501 FRAMING SECTIONS AND DETAILS
SF502 FRAMING SECTIONS AND DETAILS
SF901 ISOMETRIC VIEWS
Revisions: Date: Sheet 21 of 94
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
CIVIL AND STRUCTURAL ENGINEER
/ FUNCTIONAL DESIGNER :
M / E / P ENGINEER:
GUIDON DESIGN INC.
1221 N PENNSYLVANIA ST
INDIANAPOLIS, IN 46202
5/10/2019
C U s e rs
\b th o m a s \D o c u m e n ts
\1 .1
S
V A
O m a h a v b ill th o m s .r v t
/8
/2
:5 :3
P
M
SI002
STRUCTURAL GENERAL NOTES
NAGEL ARCHITECTS + ENGINEERS
13100 WATERTOWN PLANK ROAD, SUITE 200
ELM GROVE, WI 53122
(262)-641-0746
OMAHA VAMC - NEW PARKING
GARAGE
4101 WOOLWORTH AVE
636-116
TBD
05/10/2019 LKL WJT
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
FARRIS ENGINEERING
818 P ST. SUITE 100
LINCOLN, NE 68505
(402) 477-6163
GENERAL
THE STRUCTURE HAS BEEN DESIGNED FOR THE IN-SERVICE LOADS ONLY. THE METHODS, MEANS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, TIEDOWNS, ETC.
THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING
DRAWINGS AND SPECIFICATIONS.
THE GENERAL NOTES ON THE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE FULL WRITTEN MATERIAL SPECIFICATIONS (IF ANY) FOR THE PROJECT. IF A DISCREPANCY OCCURS BETWEEN THE NOTES AND THE FULL SPECIFICATIONS, THE MORE STRINGENT
REQUIREMENT SHALL APPLY.
NO PENETRATIONS THROUGH STRUCTURAL ELEMENTS, OTHER THAN THOSE SHOWN ON THE DRAWINGS, SHALL BE MADE WITHOUT THE
APPROVAL OF THE STRUCTURAL ENGINEER.
CONCRETE MIX DESIGN SUBMITTAL
THE CONTRACTOR SHALL SUBMIT FOR THE REVIEW OF THE STRUCTURAL ENGINEER A MIX DESIGN FOR EACH PROPOSED CLASS OF CONCRETE. EACH MIX DESIGN SHALL BE IDENTIFIED BY A MIX NUMBER OR OTHER UNIQUE IDENTIFICATION. THE CONTRACTOR SHALL NOT VARY FROM THE MIX DESIGNS NOR USE ANY CONCRETEOTHER THAN THE APPROVED MIX DESIGNS WITHOUT THE
APPROVAL OF THE
STRUCTURAL ENGINEER. MIX DESIGN SUBMITTALS SHALL INCLUDE THE FOLLOWING INFORMATION:
1. MIX DESIGN NUMBER OR UNIQUE IDENTIFICATION AND INTENDED LOCATION OF PLACEMENT.
2. CEMENT TYPE, PROPORTION AND NAME OF MANUFACTURER.
3. FLY ASH PROPORTION (WHEN USED), LABORATORY ANALYSIS CERTIFICATION, AND NAME AND LOCATION OF SUPPLIER.
4. COURSE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
5. FINE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
6. MIXING WATER PROPORTION AND SOURCE.
7. ADMIXTURE DOSAGES, PRODUCT NAME(S) AND MANUFACTURER NAME(S).
8. FIBER REINFORCEMENT DOSAGE (WHEN USED), PRODUCT NAME AND MANUFACTURER NAME.
9. DESIGN 28-DAY COMPRESSIVE STRENGTH (F'C).
10. DESIGN SLUMP RANGE.
11. DESIGN AIR-ENTRAINMENT (FOR CONCRETE REQUIRING ENTRAINED AIR).
12. STATISTICAL ANALYSIS OF LABORATORY STRENGTH TEST DATA IN ACCORDANCE WITH "STANDARD DEVIATION"
DETERMINATION OUTLINED IN ACI 318.
SHOP DRAWING SUBMITTALS
THE CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS TO ENABLE HIM TO FABRICATE, ERECT AND CONSTRUCT ALL PARTS OF THE WORK IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. THESE SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT ONLY. THE CONTRACTOR IS
RESPONSIBLE FOR ALL DIMENSIONS, ACCURACY AND FIT OF WORK.
ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE STRUCTURAL ENGINEER. DRAWINGS SUBMITTED WITHOUT CONTRACTOR'S REVIEW WILL BE RETURNED UNCHECKED.
SUBMIT ELECTRONIC VERSIONS OF SHOP DRAWINGS. SUBMIT SHOP DRAWINGS IN PDF FORMAT.
SUBMIT SHOP DRAWINGS FOR EACH OF THE FOLLOWING ITEMS:
1. CONCRETE REINFORCEMENT
2. CONCRETE MASONRY REINFORCEMENT
3. STRUCTURAL STEEL (INCLUDING DESIGN CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER
REGISTERED IN THE STATE WHERE THE PROJECT IS CONSTRUCTED FOR ALL CONNECTIONS NOT
SPECIFICALLY DETAILED ON THE DRAWINGS)
4. PRECAST CONCRETE COMPONENTS (PRECAST LINTELS, ARCHITECTURAL PRECAST)
5. METAL MESH SYSTEM (INCLUDING DESIGN CALCULATIONS AND CONNECTION DETAILS SEALED BY A
PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS CONSTRUCTED)
6. AUGER CAST PILE LOCATIONS AND REINFORCEMENT
PRODUCT DATA SUBMITTALS
THE CONTRACTOR SHALL SUBMIT FOR APPROVAL PRODUCT DATA FOR THE SPECIFIC ITEMS LISTED BELOW. CONTRACTOR SHALL NOT USE PRODUCTS OTHER THAN THOSE SUBMITTED WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER.
MANUFACTURER'S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES, AND PATTERNS AS A BASIS OF DESIGN. PRODUCTS OF AUTHORIZED EQUAL MANUFACTURER'S EQUIVALENT TO COLORS, FINISHES, TEXTURES, AND PATTERNS OF MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF TECHNICAL SPECIFICATIONS IN EVERY RESPECT MAY BE ACCEPTABLE WITH SUBMITTAL OF A COMPLETED SUBSTITUTION REQUEST CONTAINING ALL PRODUCT DATA, TESTING AND ACTUAL SAMPLES, AND UPON APPROVAL IN WRITING BY CONTRACTING OFFICER.
SUBMIT ELECTRONIC VERSIONS OF PRODUCT DATA IN PDF FORMAT TO THE STRUCTURAL ENGINEER AND COR FOR REVIEW.
1. FIBER REINFORCEMENT FOR CONCRETE
2. CONCRETE REINFORCEMENT
3. CONCRETE CURING COMPOUND
4. CONCRETE JOINT SEALANT
5. WATER STOPS
6. MASONRY JOINT REINFORCEMENT
7. EXPANSION ANCHORS
8. ADHESIVE ANCHORS
9. NON-SHRINK GROUT
10. WATERSTOPS
FOUNDATIONS
FOUNDATION EXCAVATIONS AND SOIL RELATED WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT
NUMBER 05175212 PREPARED BY TERRACON DATED DECEMBER 27, 2017.
FOUNDATIONS HAVE BEEN DESIGNED BASED ON ASSUMED ALLOWABLE CAPACITIES INDICATED BELOW. CONTRACTOR SHALL ENGAGE A LICENSED GEOTECHNICAL ENGINEER TO REVIEW THE SOIL CONDITIONS AT THE SITE AS NECESSARY TO CONFIRM THE ALLOWABLE CAPACITIES PRIOR TO PLACEMENT OF THE FOUNDATIONS. CONFIRMATION OF THE ACCEPTABILITY OF THE SOILS SHALL BE REPORTED IN
WRITING TO THE STRUCTURAL ENGINEER.
IF ACTUAL ALLOWABLE CAPACITIES ARE FOUND TO BE LESS THAN THE ASSUMED VALUES, THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY AND SHALL NOT PROCEED WITH FOUNDATION CONSTRUCTION WITHOUT REVIEW BY THE
STRUCTURAL ENGINEER.
DESIGN ALLOWABLE PILE LOADS:
COMPRESSION: 275 KIPS
TENSION: 180 KIPS
LATERAL: 16 KIPS
FOR PURPOSES OF BIDDING, ESTIMATED PILE TIP ELEVATION IS 1102 FEET. ACTUAL PILE TIP ELEVATION TO BE DETERMINED BY SPECIFIED
TESTING PROGRAM AND DRIVING CRITERIA. SEE SPECIFICATIONS.
THE CONTRACTOR MAY PROPOSE AN ALTERNATE EQUIVALENT DRIVEN PILE SYSTEM FOR REVIEW AND APPROVAL BY THE ENGINEER OF RECORD. NO DRIVEN PILE SYSTEM OTHER THAN THOSE SPECIFIED SHALL BE USED WITHOUT REVIEW AND APPROVAL BY THE ENGINEER
OF RECORD.
FOUNDATIONS AND SOILS RELATED WORK SHALL BE INSPECTED BY A LICENSED GEOTECHNICAL ENGINEER. WRITTEN FIELD REPORTS
SHALL BE FORWARDED TO THE STRUCTURAL ENGINEER AS SOON AS THEY BECOME AVAILABLE.
FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM THOSE DESCRIBED IN THE GEOTECHNICAL REPORT, SHALL BE REPORTED TO THE STRUCTURAL ENGINEER AND GEOTECHNICAL ENGINEER BEFORE FURTHER CONSTRUCTION IS ATTEMPTED.
EXCAVATIONS FOR PILE CAPS, CONTINUOUS FOOTINGS AND MAT FOUNDATIONS SHALL BE CLEANED AND HAND TAMPED TO UNIFORM
SURFACE AND SHALL BE PROTECTED AND MAINTAINED UNIFORM UNTIL CONCRETE IS PLACED.
BELOW-GRADE WALLS
DO NOT BACKFILL AGAINST BELOW-GRADE CONCRETE (OR…