36E77619B0009-0002003.pdf

PDF 5 MB Posted

Attached to
Renovate NFS Kitchen JLM Little Rock Federal contract opportunity
Solicitation number
36E77619B0009
Issued by
Department of Veterans Affairs Headquarters

About this file

36E77619B0009 0002 ATTACHMENT 7 - Asbestos Report - Little Rock Kitchen - Revised 8-26-19.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Renovate NFS Kitchen JLM Little Rock, newest first.
File Type Posted
36E77619C0076-000.docx DOCX document
36E77619B0009-0004000.docx DOCX document
36E77619B0009-0004001.pdf PDF
36E77619B0009-0003000.docx DOCX document
36E77619B0009-0002000.docx DOCX document
36E77619B0009-0002002.docx DOCX document
36E77619B0009-0002001.pdf PDF
36E77619B0009-0002004.pdf PDF
36E77619B0009-0001000.docx DOCX document
36E77619B0009-0001001.pdf PDF
36E77619B0009-006.pdf PDF
36E77619B0009-007.pdf PDF
36E77619B0009-001.docx DOCX document
36E77619B0009-005.pdf PDF
36E77619B0009-002.pdf PDF
36E77619B0009-003.pdf PDF
36E77619B0009-009.pdf PDF
36E77619B0009-011.docx DOCX document
36E77619B0009-010.pdf PDF
36E77619B0009-004.pdf PDF
36E77619B0009-008.pdf PDF
36E77619B0009-000.docx DOCX document
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

July 25, 2019

Ms. Patricia Bailey Bancroft Architects and Engineers 700 Nicholas Blvd., Suite 300 Elk Grove Village, Illinois 60007 Email: pbailey@bancroft-ae.com

RE: Pre-Renovation Asbestos Inspection Report

John L. McClellan Memorial Veterans Hospital 4300 West 75thStreet, Little Rock, AR 72205 NFS Food Production Renovation Project

Dear Ms. Bailey:

Attached please find the results of the pre-renovation asbestos inspection and bulk sampling performed at your request by TEM Environmental, Inc. (TEM). The inspection and sampling were limited to building materials scheduled for renovation of the NFS Food Production Areas at McClellan Memorial Hospital. The inspection and sampling were based on the 35% construction drawings issued by Bancroft Architects and performed on March 12, 2019 by TEM Environmental, Inc. representative Mr. Josh Roberson. Mr. Roberson is licensed by the Arkansas Department of Environmental Quality as an Asbestos Building Inspector.

Bulk material samples were collected from in compliance with the requirements of the United States Environmental Protection Agency (USEPA) Asbestos Hazard Emergency Response Act (AHERA) regulation (40 CFR Part 763) and the National Emission Standard for Hazardous Air Pollutants (NESHAP) regulation (40 CFR Part 61 Subpart M). Each sample was analyzed for asbestos content by TEM Environmental, Inc. utilizing Polarized Light Microscopy (PLM). TEM Environmental, Inc. is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for the identification of asbestos fiber in bulk material samples, Lab Accreditation Code #101130.

Table I presents the results of the assessment, sampling and laboratory analysis.

TABLE I

PRE-RENOVATION ASBESTOS INSPECTION RESULTS

JOHN L. McCLELLAN MEMORIAL VETERANS HOSPITAL

4300 WEST 75TH STREET, LITTLE ROCK, ARKANSAS

SAMPLE

IDENTIFICATION

MATERIAL DESCRIPTION

MATERIAL LOCATION

MATERIAL

CONDITION

PLM ASBESTOS LAB

RESULTS

CT01- 01 thru 02 CT03- 25 thru 26

2’ x 4’ Lay-in Ceiling Tile (Grey/ Pitted)

Various Locations Throughout the

Renovation Area Intact No Asbestos Detected

CT02- 03 thru 04 2’ x 4’ Lay-in Ceiling Tile

(White/ Pitted)

Various Locations Throughout the

Renovation Area Intact No Asbestos Detected

4300 WEST 75TH STREET, LITTLE ROCK, ARKANSAS

CONDITION

PLM ASBESTOS LAB

RESULTS

SR01- 05 thru 06 SR02- 37 thru 38

Sheet Rock/ Mud Various Locations

Throughout the Renovation Area

Intact No Asbestos Detected

CB01- 07 thru 08 Tan Cove Base Various Locations

Throughout the Renovation Area

Intact No Asbestos Detected

CM01- 09 thru 10 Cove Base Mastic on Tan

Cove Base

Various Locations Throughout the

Renovation Area Intact No Asbestos Detected

CB02- 11 thru 12 Black Cove Base Various Locations

Throughout the Renovation Area

Intact No Asbestos Detected

CM02- 13 thru 14 Mastic on Black Cove Base Various Locations

Throughout the Renovation Area

Intact No Asbestos Detected

FT01- 15 thru 16 Cream 12” x 12” Floor Tile

GC-170, GC-171, GC-174,

CG-176, GC-163, GC-169,

GC-143

Intact No Asbestos Detected

FM01- 17 thru 18 Mastic on Cream 12” x 12”

Floor Tile

GC-170, GC-171, GC-174,

CG-176, GC-161, GC-163,

GC-143

Intact 2 – 3% Chrysotile

T01- 19 thru 20 Transite Counter Tops GC-143 Intact 10 – 15% Chrysotile

FT02- 21 thru 22 Cream 12” x 12” Floor Tile GC-172 Intact No Asbestos Detected

MF02- 23 thru 24 Mastic on Cream 12” x 12”

Floor Tile GC-172 Intact 1 – 3% Chrysotile

CT04- 27 thru 28 2’ x 4’ White Replacement

Ceiling Tile

Various Locations Throughout the

Renovation Area Intact No Asbestos Detected

C01- 29 thru 30 Brown Ceramic Floor Tile Kitchen and Dishwash

Area Intact No Asbestos Detected

CG01- 31 thru 32 Grout on Brown Ceramic Tile Kitchen and Dishwash

Area Intact No Asbestos Detected

C02- 33 thru 34 Yellow Ceramic Tile on Walls GC-163 and GC-174 Intact No Asbestos Detected

CG02- 35 thru 36 Grout on Yellow Ceramic Tile GC-163 and GC-174 Intact No Asbestos Detected

CB03- 39 thru 40 Cream Cove Base Various Locations

Throughout the Renovation Area

Intact No Asbestos Detected

CM03- 41 thru 42 Mastic on Cream Cove Base Various Locations

Throughout the Renovation Area

Intact No Asbestos Detected

4300 WEST 75TH STREET, LITTLE ROCK, ARKANSAS

CONDITION

PLM ASBESTOS LAB

RESULTS

CB04- 43 thru 44 Grey Cove Base GA-103 Intact No Asbestos Detected

CM04- 45 thru 46 Mastic on Grey Cove Base GA-103 Intact No Asbestos Detected

PM01- 47 thru 49 Mud on Pipe Insulation in

Dish Room Chase GC-166 Intact No Asbestos Detected

PM01- 50 thru 51 12” x 12” Blue Floor Tile GA-103 Intact No Asbestos Detected

FM03- 52 thru 53 Mastic on 12” x 12” Blue

Floor Tile GA-103 Intact Trace – 2% Chrysotile

CB05- 54 thru 55 Brown Cove Base GA-104 Intact No Asbestos Detected

CM05- 56 thru 57 Mastic on Brown Cove Base GA-104 Intact No Asbestos Detected

L03- 58 thru 59 Blue Ceramic Tile GA-104 Intact No Asbestos Detected

G03- 60 thru 61 Grout on Blue Ceramic Tile GA-104 Intact No Asbestos Detected

C04- 62 thru 63 Small Brown Ceramic Tile GA-104 Intact No Asbestos Detected

G04- 64 thru 65 Grout on Small Brown

Ceramic Tile GA-104 Intact No Asbestos Detected

FP01- 66 thru 72 Structural Fireproofing Throughout, Accessible

Above Ceilings Intact No Asbestos Detected

T02- Not Sampled Transite Panels in Fume

Hood GC-145 Intact

Assumed to be Asbestos Containing

Materials

Not Sampled HVAC Duct Seam Sealant Throughout Renovation

Areas Intact

Asbestos Containing Material Per VA

Records

Conclusions

The pre-renovation inspection and sampling has confirmed the presence of asbestos in selective areas of floor tile mastic, laboratory countertops, and the sealant on HVAC Ductwork. Additionally, asbestos is assumed to be present within the interior liners of the fume hood in Lab GC143

Recommendations

Asbestos Abatement - Removal and disposal of all asbestos containing materials required for renovation as identified in the table above. All abatement shall be by an Arkansas Licensed Asbestos Abatement Contractor per applicable EPA, OSHA and Arkansas Regulations.

Asbestos containing Duct Seam Sealant within the renovation area is not to be impacted during the renovation. Should disturbance to the material be required to complete the renovation, the Duct Seam Sealant shall be abated before disturbance.

Implement and adhere to all VA specifications and procedures.

Maintain project abatement records and air clearance results as required by applicable asbestos regulations and any project specifications.

Should suspect asbestos containing materials not listed in this report be discovered during renovation or demolition activities, stop work and perform representative sampling and analysis for asbestos identification prior to disturbance.

See Attachment A for Asbestos Laboratory Reports and Sample Chain of Custody Documentation, Attachment B for Inspector Accreditation, and Attachment C for Photographs.

Thank you for the opportunity to perform the pre-renovation inspection and sampling for Bancroft Architects + Engineers. TEM Environmental, Inc. would be happy to assist any abatement projects within the building with asbestos air monitoring and project record keeping services should you need support moving forward. Please feel free to contact me directly at 847-226-8509 should you have any questions or wish to discuss the results or recommendations in more detail.

Sincerely, TEM ENVIRONMENTAL, INC.

Daniel Juneau Vice President of Operations

APPENDIX A

Laboratory Results and Sample Chain of Custody

BULK ASBESTOS SAMPLE EVALUATION

POLARIZED LIGHT MICROSCOPY (PLM) TECHNIQUE

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360144 Gray N/D 25-30 65-70

0-10Chrysotile Amosite

Cellulose Glass

CT01-01

2x4 Lay-in CT (Gray/Pitted)

360145 Gray N/D 25-30 65-70

0-10Chrysotile Amosite

Cellulose Glass

CT01-02

2x4 Lay-in CT (Gray/Pitted)

360146 White/Gray N/D 85-90 Trace

10-15Chrysotile Amosite

Cellulose Glass

CT02-03

2x4 Lay-in CT (White/Pitted)

360147 White/Gray N/D 85-90 10-15Chrysotile Amosite

Cellulose Glass

CT02-04

2x4 Lay-in CT (White/Pitted)

360148 Brown/White N/D 5-7 1-2

91-94Chrysotile Amosite

Cellulose Glass

SR01-05

Sheet Rock/Mud

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US government. An estimate of the laboratory uncertainity is available upon request.

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360149 Brown/White N/D 5-7 1-2

91-94Chrysotile Amosite

Cellulose Glass

SR01-06

Sheet Rock/Mud

360150 Tan N/D 90-100Chrysotile Amosite

Cellulose Glass

CB01-07

Tan Cove Base

360151 Tan N/D 90-100Chrysotile Amosite

Cellulose Glass

CB01-08

Tan Cove Base

360152 Brown N/D Trace 90-100Chrysotile Amosite

Cellulose Glass

CM01-09

Mastic on Tan Cove Base

360153 Brown N/D 90-100Chrysotile Amosite

Cellulose Glass

CM01-10

Mastic on Tan Cove Base

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360154 Black N/D 90-100Chrysotile Amosite

Cellulose Glass

CB02-11

Black Cove Base

360155 Black N/D 90-100Chrysotile Amosite

Cellulose Glass

CB02-12

Black Cove Base

360156 Brown N/D Trace 90-100Chrysotile Amosite

Cellulose Glass

CM02-13

Mastic on Black Cove Base

360157 Brown N/D 1-2 98-99Chrysotile Amosite

Cellulose Glass

CM02-14

Mastic on Black Cove Base

360158 Cream N/D 90-100Chrysotile Amosite

Cellulose Glass

FT01-15

Cream 12x12 Floor Tile

SLM

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360159 Cream N/D 90-100Chrysotile Amosite

Cellulose Glass

FT01-16

Cream 12x12 Floor Tile

SLM

360160 Black Yes 2-3 97-98Chrysotile Amosite

Cellulose Glass

FM01-17

Mastic on Cream 12x12 FT

360161 Black Yes 2-3 Trace 97-98Chrysotile Amosite

Cellulose Glass

FM01-18

Mastic on Cream 12x12 FT

360162 Black Yes 10-15 85-90Chrysotile Amosite

Cellulose Glass

T01-19 Transite Countertops

360163 Black Yes 10-15 85-90Chrysotile Amosite

Cellulose Glass

T01-20 Transite Countertops

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360164 Cream N/D 90-100Chrysotile Amosite

Cellulose Glass

FT02-21

Cream 12x12 Floor Tile

SLM

360165 Cream N/D 90-100Chrysotile Amosite

Cellulose Glass

FT02-22

Cream 12x12 Floor Tile

SLM

360166 Black Yes 1-2 1-2 96-98Chrysotile Amosite

Cellulose Glass

FM02-23

Mastic on Cream 12x12 FT

360167 Black Yes 2-3 Trace 97-98Chrysotile Amosite

Cellulose Glass

FM02-24

Mastic on Cream 12x12 FT

360168 Gray N/D 25-30 65-70

0-10Chrysotile Amosite

Cellulose Glass

CT03-25

2x4 Ceiling Tile (Gray/Pitted)

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360169 Gray N/D 25-30 65-70

0-10Chrysotile Amosite

Cellulose Glass

CT03-26

2x4 Ceiling Tile (Gray/Pitted)

360170 White/Gray N/D 80-85 5-10

5-15Chrysotile Amosite

Cellulose Glass

CT04-027

2x4 White Replacement CT

360171 White/Gray N/D 80-85 5-10

5-15Chrysotile Amosite

Cellulose Glass

CT04-028

2x4 White Replacement CT

360172 Brown N/D 90-100Chrysotile Amosite

Cellulose Glass

C01-29 Brown Ceramic Floor Tile

360173 Brown N/D 90-100Chrysotile Amosite

Cellulose Glass

C01-30 Brown Ceramic Floor Tile

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360174 Gray N/D 90-100Chrysotile Amosite

Cellulose Glass

CG01-31

Grout on Brown Ceramic FT

360175 Gray N/D Trace 90-100Chrysotile Amosite

Cellulose Glass

CG01-32

Grout on Brown Ceramic FT

360176 Yellow N/D 90-100Chrysotile Amosite

Cellulose Glass

C02-33 Yellow Ceramic Tile on Walls

360177 Yellow N/D 90-100Chrysotile Amosite

Cellulose Glass

C02-34 Yellow Ceramic Tile on Walls

360178 Yellow N/D 90-100Chrysotile Amosite

Cellulose Glass

CG02-35

Grout on Yellow Ceramic Tile

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360179 Yellow N/D 90-100Chrysotile Amosite

Cellulose Glass

CG02-36

Grout on Yellow Ceramic Tile

360180 Brown/White N/D 5-7 2-3

90-93Chrysotile Amosite

Cellulose Glass

SR02-37

Sheet Rock/Mud

360181 Brown/White N/D 5-7 2-3

90-93Chrysotile Amosite

Cellulose Glass

SR02-38

Sheet Rock/Mud

360182 Cream N/D 90-100Chrysotile Amosite

Cellulose Glass

CB03-39

Cream Cove Base

360183 Cream N/D 90-100Chrysotile Amosite

Cellulose Glass

CB03-40

Cream Cove Base

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360184 Yellow N/D Trace 90-100Chrysotile Amosite

Cellulose Glass

CM03-41

Mastic on Cream Cove Base

360185 Yellow N/D 90-100Chrysotile Amosite

Cellulose Glass

CM03-42

Mastic on Cream Cove Base

360186 Gray N/D 90-100Chrysotile Amosite

Cellulose Glass

CB04-43

Gray Cove Base

360187 Gray N/D 90-100Chrysotile Amosite

Cellulose Glass

CB04-44

Gray Cove Base

360188 Yellow N/D Trace 90-100Chrysotile Amosite

Cellulose Glass

CM04-45

Mastic on Gray Cove Base

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360189 Brown N/D 1-2 98-99Chrysotile Amosite

Cellulose Glass

CM04-46

Mastic on Gray Cove Base

360190 White/Yellow N/D 85-95

5-15Chrysotile Amosite

Cellulose Glass

PM01-47

Mud on Pipe Insul. - Dish Rm.

360191 White/Yellow N/D 85-95

5-15Chrysotile Amosite

Cellulose Glass

PM01-48

Mud on Pipe Insul. - Dish Rm.

360192 White/Yellow N/D 85-95

5-15Chrysotile Amosite

Cellulose Glass

PM01-49

Mud on Pipe Insul. - Dish Rm.

360193 Blue N/D 90-100Chrysotile Amosite

Cellulose Glass

FT03-50

12x12 Blue Floor Tile

SLM

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360194 Blue N/D 90-100Chrysotile Amosite

Cellulose Glass

FT03-51

12x12 Blue Floor Tile

SLM

360195 Black No Trace 90-100Chrysotile Amosite

Cellulose Glass

FM03-52

Mastic on Blue 12x12 FT

360196 Black Yes 1-2 Trace 98-99Chrysotile Amosite

Cellulose Glass

FM03-53

Mastic on Blue 12x12 FT

360197 Brown N/D 90-100Chrysotile Amosite

Cellulose Glass

CB05-54

Brown Cove Base

360198 Brown N/D 90-100Chrysotile Amosite

Cellulose Glass

CB05-55

Brown Cove Base

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360199 Yellow N/D 1-2 98-99Chrysotile Amosite

Cellulose Glass

CM05-56

Mastic on Brown Cove Base

360200 Yellow N/D Trace 90-100Chrysotile Amosite

Cellulose Glass

CM05-57

Mastic on Brown Cove Base

360201 Blue N/D 90-100Chrysotile Amosite

Cellulose Glass

L03-58 Blue Ceramic Tile

360202 Blue N/D 90-100Chrysotile Amosite

Cellulose Glass

L03-59 Blue Ceramic Tile

360203 Yellow N/D 90-100Chrysotile Amosite

Cellulose Glass

G03-60 Grout on Blue Ceramic Tile

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360204 Yellow N/D 90-100Chrysotile Amosite

Cellulose Glass

G03-61 Grout on Blue Ceramic Tile

360205 Brown N/D 90-100Chrysotile Amosite

Cellulose Glass

C04-62 Small Brown Ceramic Tile

360206 Brown N/D 90-100Chrysotile Amosite

Cellulose Glass

C04-63 Small Brown Ceramic Tile

360207 Gray N/D 90-100Chrysotile Amosite

Cellulose Glass

G04-64 Grout on Brown Ceramic Tile

360208 Gray N/D Trace 90-100Chrysotile Amosite

Cellulose Glass

G04-65 Grout on Brown Ceramic Tile

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360209 Gray N/D 35-45 2-3

52-63Chrysotile Amosite

Cellulose Glass

FP01-66

Fireproofing above Lay-in CT

360210 Gray N/D 35-40 3-5

55-62Chrysotile Amosite

Cellulose Glass

FP01-67

Fireproofing above Lay-in CT

360211 Gray N/D 35-45 2-3

52-63Chrysotile Amosite

Cellulose Glass

FP01-68

Fireproofing above Lay-in CT

360212 Gray N/D 35-45 2-3

52-63Chrysotile Amosite

Cellulose Glass

FP01-69

Fireproofing above Lay-in CT

360213 Gray N/D 35-45 2-3

52-63Chrysotile Amosite

Cellulose Glass

FP01-70

Fireproofing above Lay-in CT

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

Company Name: Bancroft Contact

Client Project Ref: 19018

TEM Project: 56721 Analyzed by: Lori Boersma Date Analyzed: 5/21/2019

TEM COLOR

ID.

ACM Filler Binder

Comments

Fibrous Materials

Asbestos Fibers Type Percent

Non-Asbestos Fibers Type Percent

Client Sample ID

Sample Information

Address:

Non-Fibrous Materials

Description

NVLAP LAB CODE: 101130-0

Project Location: McClellan VA Little Rock

TEM Environmental

360214 Gray N/D 35-45 5-10

45-60Chrysotile Amosite

Cellulose Glass

FP01-71

Fireproofing above Lay-in CT

360215 Gray N/D 35-40 2-3

57-63Chrysotile Amosite

Cellulose Glass

FP01-72

Fireproofing above Lay-in CT

Key: ACM = Asbestos Containing Material as defined in USEPA NESHAP Regulation; TR = Trace; N/D = None Detected

Samples were analyzed following the procedures contained in the EPA Method 600/R-93/116, July 1993. This report applies only to samples tested.

SLM: The optical resolution of polarized light microscopy limits the size of fibers that are visible. In samples where very small fibers may be present, the asbestos fibers may be smaller than the resolution limit of a polarized light microscope. In those cases, the result of the PLM analysis is not conclusive where the sample is reported as non-asbestos. Samples that are expected to contain small fibers (such as floor tile samples and vermiculite) and that are reported as non-asbestos by PLM should be further anlayzed by transmission electron microscopy.

Report Approved by:630-790-0880 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

This report may not be reproduced except in full and with the approval of the Laboratory. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US

APPENDIX B

Inspector Accreditation

APPENDIX C

Photographs

2x4 Grey Pitted Lay-in Ceiling Tiles

2x4 White Pitted Lay-in Ceiling Tiles

Sheet Rock and Mud Walls

Tan Cove Base and Mastic

Black Cove Base and Mastic

12x12 Cream Floor Tile and Mastic

Transite Counter Tops

Transite Panels in Vent Hood (Not Sampled)

12x12 Cream Floor Tile and Mastic

2x4 Grey Pitted Lay-in Ceiling Tile

2x4 White Replacement Lay-in Ceiling Tile

Brown Ceramic Floor Tile and Grout

Yellow Ceramic Wall Tile and Grout

Sheet Rock and Mud Walls

Cream Cove Base and Mastic

Grey Cove Base and Mastic

Mud on Fiberglass Pipe Insulation

12x12 Blue Floor Tile and Mastic

Brown Cove Base and Mastic

Blue Ceramic Tile and Grout

Small Brown Ceramic Tile and Grout

Spray-applied Fire Proofing

File details come from the government source that posted it.