36E77618R0062-007.pdf
PDF 14 MB Posted
- Attached to
- Research Addition JP, Construction Federal contract opportunity
- Solicitation number
- 36E77618R0062
About this file
36E77618R0062 S02 Attachment 6 523-307 Research Addition JP - Bid Docs - Plans Vol 2.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36E77619C0005_1.docx | DOCX document | |
| 36E77618R0062-0002000.docx | DOCX document | |
| 36E77618R0062-0001000.docx | DOCX document | |
| 36E77618R0062-012.docx | DOCX document | |
| 36E77618R0062-004.pdf | ||
| 36E77618R0062-009.pdf | ||
| 36E77618R0062-006.pdf | ||
| 36E77618R0062-011.docx | DOCX document | |
| 36E77618R0062-001.docx | DOCX document | |
| 36E77618R0062-003.pdf | ||
| 36E77618R0062-005.pdf | ||
| 36E77618R0062-010.pdf | ||
| 36E77618R0062-002.pdf | ||
| 36E77618R0062-008.pdf | ||
| 36E77618R0062-000.docx | DOCX document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING 1
BUILDING 1F
ACA ADDITION
AREA OF WORK
SITE LOCATION MAP
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg:
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig ht h in ch o ne fo ot on e q ua rte r i nc on e h al f th re e e ig hs th re e q ua rte rs i
6" on e i
6" on e a nd on e h a lf i nc he s f oo t 6"
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
SITE LOCATION MAP
JAMAICA PLAIN CAMPUS
VA JAMAICA PLAIN CAMPUS
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
3-31-2016
Title Sheet Volume 2
+T002
PNDW
523-307 AE Research Addition
DEPARTMENT OF VETERANS AFFAIRS
BOSTON HEALTHCARE SYSTEM
JAMAICA PLAIN CAMPUS
100% SUBMITTAL - BID DOCUMENTS (VOLUME 2)
SHEET INDEX - VOLUME 1
SHEET
NUMBER Sheet Name
SHEET INDEX - VOLUME 1
SHEET
NUMBER Sheet Name
SF-103 Third Floor Framing Plan SF-104 Roof Framing Plan SF-200 Column Schedules & Details SF-500 Framing Sections & Details SF-501 Framing Sections & Details SF-502 Framing Sections & Details SF-503 Framing Sections & Details SF-504 Framing Sections & Details SF-505 Framing Sections & Details
SHEET INDEX - VOLUME 1
SHEET
NUMBER Sheet Name
+T001 Title Sheet Volume 1 General -G-001 VA Project General Notes -G-002 Project General Notes & Material Legend Civil VF101 Survey-Plan-Field CD101 Civil-Plan-Demo CS101 Civil-Plan-Site CS102 Civil-Site-Enlargements CG101 Civil-Plan-Grading CU101 Civil-Plan-Utilities CS501 Civil-Details-Site CS502 Civil-Details-Site CS503 Civil-Details-Site Architectural AD100 Ground Floor & First Floor Demolition Plan AD101 Second Floor & Third Floor Demolition Plan AD201 Demolition Elevations AS001 Assembly Types AS002 Typical Mounting Heights and Layouts AS003 Ground and First Floor Code Plans AS004 Second and Third Floor Code Plans AS005 Deduct Alternates AS100A Ground Floor Plan A AS100B Ground Floor Plan B AS101A First Floor Plan A AS101B First Floor Plan B AS102A Second Floor Plan A AS102B Second Floor Plan B AS103A Third Floor Plan A AS103B Third Floor Plan B AS104 Roof Plan AS105 Ground & 1st Floor Furniture, Equipment, and Floor Finish Plan AS106 2nd & 3rd Floor Furniture, Equipment, and Floor Finish Plan AS107 Ground Floor& First Floor Reflected Ceiling Plan AS108 Second Floor, Third Floor, Fourth Floor Reflected Ceiling Plan AS109 Ceiling Systems and Details AS201 Exterior Elevations AS202 Exterior Elevations AS203 Exterior Elevations AS204 Interior Elevations - Ground Floor AS205 Interior Elevations - Ground & 1st Floor Circulation AS206 Interior Elevations - 1st Floor AS207 Interior Elevations - 2nd & 3rd Floor AS208 Interior Elevations - Toilet Rooms AS301 Building Sections AS302 Building Sections AS303 Wall Sections AS304 Wall Sections AS305 Wall Sections AS306 Wall Sections AS307 Not Used AS401 Enlarged Plans AS402 Stair and Elevator Plans, 4th Floor Plan AS403 Stair and Elevator Sections AS404 Stair Plans & Sections AS405 Stair and Mech Shaft Plans and Details AS406 Stair Details AS407 Stair And Elevator Shaft Details AS501 Exterior Details AS502 Exterior Details AS503 Exterior Details AS504 Exterior Details AS505 Exterior Details AS506 Interior Details AS507 Typical Interior Details AS508 Typical Interior Firestopping, Sealing, And Shaftwall Details AS509 Typical Casework Details & Misc Details AS601 Door and Frame Schedule, Notes, and Details AS602 Curtain Walll Types AS603 Curtain Wall Types And Details AS604 Curtain Wall Details AS605 Curtain Walll Details AS606 Curtain Wall Details AS607 Curtain Wall Details AS608 Curtain Walll Details AS609 Curtain Wall Details AS610 Room Finish Schedule AS611 Finishes By Division Shielding RF0.0 Cover RF1.0 Foundation Plan RF1.1 Ceiling Support Layout RF1.2 Floor Plan RF1.3 Silicone Steel Ceiling RF1.4 Silicone Steel Floor RF2.0 Elevations RF2.1 Silicone Steel Elevations RF3.0 Details RF3.1 Details RF4.0 Autoseal 2 Door Structural SS-001 General Notes SB-100 Foundation Plan SB-300 Typical Foundation Sections & Details SB-301 Foundation Sections & Details SB-302 Foundation Sections & Details SB-303 Foundation Sections & Details SB-304 Foundation Sections & Details SF-101 First Floor Framing Plan SF-102 Second Floor Framing Plan
SHEET INDEX - VOLUME 2
SHEET
NUMBER Sheet Name
10-E600 Electrical Ground Floor Panel Schedules & Lighting Fixture Schedule 10-E601 Electrical Ground Floor Panel Schedules 10-E602 Electrical First & Second Floor Panel Schedules 10-E603 Electrical Third Floor Panel Schedules Plumbing 10-PL001 Plumbing Legend & General Notes 10-PD100 Plumbing Domestic Water Ground Floor Demo Plan 10-PD101 Plumbing Sanitary and Vent Ground Floor Demo Plan 10-PL100A Plumbing Domestic Water Ground Floor Plan A 10-PL100B Plumbing Domestic Water Ground Floor Plan B 10-PL101A Plumbing Sanitary and Vent Ground Floor Plan A 10-PL101B Plumbing Sanitary and Vent Ground Floor Plan B 10-PL102A Plumbing Domestic Water First Floor Plan A 10-PL102B Plumbing Domestic Water First Floor Plan B 10-PL103A Plumbing Sanitary and Vent First Floor Plan A 10-PL103B Plumbing Sanitary and Vent First Floor Plan B 10-PL104A Plumbing Domestic Water Second Floor Plan A 10-PL104B Plumbing Domestic Water Second Floor Plan B 10-PL105A Plumbing Sanitary and Vent Second Floor Plan A 10-PL105B Plumbing Sanitary and Vent Second Floor Plan B 10-PL106A Plumbing Domestic Water Third Floor Plan A 10-PL106B Plumbing Domestic Water Third Floor Plan B 10-PL107A Plumbing Sanitary and Vent Third Floor Plan A 10-PL107B Plumbing Sanitary and Vent Third Floor Plan B 10-PL108 Plumbing Sanitary and Vent Roof Plan 10-PL501 Plumbing Details & Schedules Fire Protection
FP-001 FIRE PROTECTION-TITLE SHEET
FP-100 FIRE PROTECTION-GROUND FLOOR PLAN
FP-101 FIRE PROTECTION-FIRST FLOOR PLAN
FP-102 FIRE PROTECTION-SECOND FLOOR PLAN
SHEET INDEX - VOLUME 2
SHEET
NUMBER Sheet Name
+T002 Title Sheet Volume 2 Mechanical 10-MH001 HVAC Legend & General Notes 10-MD101 HVAC Ductwork Ground Floor Demo 10-MD102 HVAC Piping Ground Floor Demo 10-MD103 HVAC Piping First Floor Demo 10-MH100A HVAC Ductwork Ground Floor Plan A 10-MH100B HVAC Ductwork Ground Floor Plan B 10-MH101A HVAC Piping Ground Floor Plan A 10-MH101B HVAC Piping Ground Floor Plan A 10-MH101C HVAC Piping Ground Floor Plan C 10-MH102A HVAC Ductwork First Floor Plan A 10-MH102B HVAC Ductwork First Floor Plan B 10-MH103A HVAC Piping First Floor Plan A 10-MH103B HVAC Piping First Floor Plan B 10-MH104A HVAC Ductwork Second Floor Plan A 10-MH104B HVAC Ductwork Second Floor Plan B 10-MH105A HVAC Piping Second Floor Plan A 10-MH105B HVAC Piping Second Floor Plan B 10-MH106A HVAC Ductwork Third Floor Plan A 10-MH106B HVAC Ductwork Third Floor Plan B 10-MH107A HVAC Piping Third Floor Plan A 10-MH107B HVAC Piping Third Floor Plan A 10-MH108 HVAC Ductwork Roof Plan 10-MH109 HVAC Piping Roof Plan 10-MH501 HVAC Details 10-MH502 HVAC Details 10-MH503 HVAC Details 10-MH601 HVAC Schedules 10-MH602 HVAC Schedules 10-MH603 HVAC Schedules 10-MH604 HVAC Schematic Diagrams 10-MH801 HVAC Controls 10-MH802 HVAC Controls 10-MH803 HVAC Controls Electrical 10-E000 Electrical Legend & General Notes 10-ED100 Electrical Site Plan Demo 10-ED101 Electrical Ground and Second Floor Demo 10-ES100 Electrical Site Plan New 10-ES500 Electrical Site Details 10-E001 Electrical One-Line Normal System Riser 10-E002 Electrical One-Line Emergency System Riser 10-E003 Data/Tel System One-Line Diagrams & Risers 10-E004 Misc. System One-Line Diagrams & Risers 10-EL100A Electrical Lighting Ground Floor Plan A 10-EL100B Electrical Lighting Ground Floor Plan B 10-EL101A Electrical Lighting First Floor Plan A 10-EL101B Electrical Lighting First Floor Plan B 10-EL102A Electrical Lighting Second Floor Plan A 10-EL102B Electrical Lighting Second Floor Plan B 10-EL103A Electrical Lighting Third Floor Plan A 10-EL103B Electrical Lighting Third Floor Plan B 10-EP100A Electrical Power Ground Floor Plan A 10-EP100B Electrical Power Ground Floor Plan B 10-EP100C Electrical Power Ground Floor Plan C 10-EP101A Electrical Power First Floor Plan A 10-EP101B Electrical Power First Floor Plan B 10-EP102A Electrical Power Second Floor Plan A 10-EP102B Electrical Power Second Floor Plan B 10-EP103A Electrical Power Third Floor Plan A 10-EP103B Electrical Power Third Floor Plan B 10-EP104 Electrical Power Roof New 10-ET001 Electrical Systems Ground Floor Routing Plan A 10-ET002 Electrical Systems Ground Floor Routing Plan B 10-ET003 Electrical Systems First Floor Routing Plan 10-ET004 Electrical Systems Third Floor Routing Plan 10-ET100A Electrical Systems Ground Floor Plan A 10-ET100B Electrical Systems Ground Floor Plan B 10-ET101A Electrical Systems First Floor Plan A 10-ET101B Electrical Systems First Floor Plan B 10-ET102A Electrical Systems Second Floor Plan A 10-ET102B Electrical Systems Second Floor Plan B 10-ET103A Electrical Systems Third Floor Plan A 10-ET103B Electrical Systems Third Floor Plan B 10-ET400 Electrical Enlarged ACA Tel/Comm Rooms 10-ET401 Electrical Enlarged Research Tel/Comm Data Room 10-E400 Electrical Enlarged Ground Floor MRI New 10-E500 Electrical MRI Details 10-E501 Electrical Details 10-E502 Electrical Lighting Details 10-E503 Electrical Details - LIghtning Protection 10-E504 Electrical Details
V
MPV
T
PS
F
P
P
P C
S
FD
FSD
PP
GAS PIPING
FLOW SWITCH
ISOLATION ROOM PRESSURIZATION CONTROLLER
EQUIPMENT, GRILLE, REGISTER OR DIFFUSER TAG
AUTOMATIC AIR VENT
VENT PIPING
MULTIPURPOSE VALVE
PRESSURE SWITCH
THERMOMETER
HOT WATER PIPING
POINT OF CONNECTION TO EXISTING
DUCT STATIC PRESSURE SENSOR
VARIABLE AIR VOLUME BOX
COLD WATER PIPING
PRESSURE REGULATING VALVE
UNION
CIRCUIT BALANCE VALVE
SWING CHECK VALVE
BALL VALVE
BUTTERFLY VALVE
PRESSURE GAUGE W/PETCOCK
THERMOSTAT
GATE VALVE
MANUAL AIR VENT
MEDIUM PRESSURE CONDENSATE RETURN
MEDIUM PRESSURE STEAM
LOW PRESSURE CONDENSATE RETURN
HOT WATER RETURN PIPING
CHILLED WATER SUPPLY PIPING
HOT WATER SUPPLY PIPING
CHILLED WATER RETURN PIPING
LOW PRESSURE STEAM
MPC
MPS
HWS
HWR
CHWS
CHWR
LPC
LPS
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CWR
CWS
PIPE DROP
PIPE RISER
PIPE TEE - DOWN
PIPE TEE - UP
PIPE CONNECTION
PIPE BREAK - TO CONTINUE
DIRECTION OF FLOW
EXISTING RECTANGULAR DUCT RUN W/ SIZE
DESIGNATION
EXISTING CIRCULAR DUCT RUN W/ SIZE DESIGNATION
DEMOLITION RECTANGULAR DUCT RUN W/ SIZE
DESIGNATION
DEMOLITION CIRCULAR DUCT RUN W/ SIZE
DESIGNATION
NEW RECTANGULAR DUCT RUN W/ SIZE DESIGNATION
NEW CIRCULAR DUCT RUN W/ SIZE DESIGNATION
NEW RECTANGULAR DUCT - UP
NEW CIRCULAR DUCT RUN - UP
NEW RECTANGULAR DUCT - DOWN
NEW CIRCULAR DUCT RUN - DOWN
EXISTING FLEX DUCT RUN W/ SIZE DESIGNATION
DEMOLITION FLEX DUCT RUN W/ SIZE DESIGNATION
NEW FLEX DUCT RUN W/ SIZE DESIGNATION
ACOUSTICALLY LINED DUCT RUN
ELEVATION CHANGE IN DUCTWORK - UP
RECTANGULAR TO RECTANGULAR DUCTWORK TRANSITION
RECTANGULAR TO CIRCULAR DUCTWORK TRANSITION
RECTANGULAR TO RECTANGULAR DUCTWORK TRANSITION
ELEVATION CHANGE IN DUCTWORK - DOWN
DUCTWORK BREAK - TO CONTINUE
RG, RR
EG, ER
SD, SR, SG
SD, SR, SG
SD, SR, SG
SD, SR, SG
SD, SR, SG
DIFFUSER, REGISTER OR GRILLE TAG, WITH CFM
AIRFLOW
NOTE CALL OUT1
COMBINATION FIRE SMOKE DAMPER
FIRE DAMPER
MANUAL VOLUME DAMPER
HUMIDIFIER
PIPE CAP
PIPE GUIDE
PIPE ANCHOR
CW
HW
V
G
REHEAT HOT WATER RETURN PIPING
REHEAT HOT WATER SUPPLY PIPINGRHWS
RHWR
REVISION TAG
REVISION CLOUD
DUCT SIZE12�, 12x12
AD
AFF
AFG
AP
AS
ATC
BFP
BOD
BTU
BTUH
C
C&HW
CAP
CC
CD
CFM
COL
CONN
CV
DB
DDC
DIA
DN
DO
DWG OR DWGS
E, EX OR (E)
EA
EAT
EC
ECU
EF
EG
EL
EMS
ER
ERV
ESP
ET
ETO
ETR
EWT
EXH
FA
FC
FD
FLA
FLR
FPI
FPM
FSD
FT
FTR
GAL
GC
GE
GPM
GV
HC
HP
HVAC
HW
ID
IH
IN
KW
L
LAT
LWT
MBH
MD
MECH
MTD
N.C. OR NC
N.O. OR NO
NIC
NOM
NTS
O.A. OR OA
OAT
OBD
OD
OED
PC
PD
PSI
PRV
RA
REF
RF
RG
RHWR
RHWS
RM
RR
RV
SA
SAT
SF
SP
SPD
SPEC
SR
SS
TG
TOD
TSTAT
TYP
U.G.
U.S.
UC
V
VAV
VB
VFD
VTR
W W/
WB
WMS
DUCT ACCESS DOOR
ABOVE FINISHED FLOOR
ABOVE FINISH GRADE
ACCESS PANEL
AIR SEPARATOR
AUTOMATIC TEMPERATURE CONTROL
BACK FLOW PREVENTER
BOTTOM OF DUCT
BRITISH THERMAL UNIT
BRITISH THERMAL UNIT PER HOUR
CONVECTOR
COLD & HOT WATER
CAPACITY
COOLING COIL
CEILING DIFFUSER
CUBIC FEET PER MINUTE
COLUMN
CONNECT
CONTROL VALVE
DRY BULB TEMPERATURE
DIRECT DIGITAL CONTROL
DIAMETER
DOWN
DIGITAL OUTPUT
DRAWINGS
EXISTING
EXHAUST AIR
ENTERING AIR TEMPERATURE
ELECTRICAL CONTRACTOR
EVAPORATIVE CONDENSING UNIT
EXHAUST FAN
EXHAUST AIR GRILLE
EXPANSION LOOP
ENERGY MANAGEMENT SYSTEM
EXHAUST AIR REGISTER
EXHAUST ON ROOF
EXTERNAL STATIC PRESSURE
EXPANSION TANK
EXISTING TO BE REMOVED
ETHYLENE OXIDE
ENTERING WATER TEMPERATURE
EXHAUST
FREE AREA
FLEXIBLE CONNECTION
FIRE DAMPER
FULL LOAD AMPS
FLOOR
FINS PER INCH
FEET PER MINUTE
COMBINATION FIRE AND SMOKE DAMPER
FEET
FIN TUBE RADIATION
GALLONS
GENERAL CONTRACTOR
GENERAL EXHAUST
GALLONS PER MINUTE
GATE VALVE
HEATING COIL
HORSE POWER
HEATING, VENTILATION AND AIR COND.
HOT WATER
INSIDE DIAMETER
INTAKE HOOD
INCHES
KILOWATTS
LOUVER
LEAVING AIR TEMPERATURE
LEAVING WATER TEMPERATURE
THOUSANDS OF B.T.U.'S PER HOUR
MOTORIZED DAMPER
MECHANICAL
MOUNTED
NORMALLY CLOSED
NORMALLY OPEN
NOT IN CONTRACT
NOMINAL
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
OPPOSED BLADE DAMPER
OUTSIDE DIAMETER
OPEN ENDED DUCT
PLUMBING CONTRACTOR
PRESSURE DROP
POUNDS PER SQUARE INCH
PRESSURE REDUCING VALVE
RETURN AIR
RETURN EXHAUST FAN
RETURN FAN
RETURN AIR GRILLE
REHEAT WATER RETURN
REHEAT WATER SUPPLY
ROOM
RETURN AIR REGISTER
RELIEF VALVE
SUPPLY AIR
SUPPLY AIR TEMPERATURE
SQUARE FEET
STATIC PRESSURE
SPEED
SPECIFICATION
SUPPLY AIR REGISTER
STAINLESS STEEL
TRANSFER AIR GRILLE
TOP OF DUCT
THERMOSTAT
TYPICAL
UNDER GRADE
UNDER SLAB
UNDERCUT DOOR
VENT
VARIABLE AIR VOLUME
VACUUM BREAKER
VARIABLE FREQUENCY DRIVE
VENT THROUGH ROOF
WASTE
WITH
WET BULB TEMPERATURE (°F)
WIRE MESH SCREEN
HOT WATER RETURN PIPINGHWR
GLOBE VALVE
FLANGE
STRAINER W/DRAIN VALVE AND CAP
PRESSURE PORT ("PETE'S PLUG")
HIGH PRESSURE STEAMHPS
CHEMICAL SUPPLY PIPESCHEM
SANITARY DRAIN ABOVE FLOOR OR GRADESAN
HIGH-TEMPERATURE HOT WATER RETURNHTWR
MEDIUM-TEMPERATURE HOT WATER RETURNMTWR
FUEL OIL TANK VENTFOV
HIGH-TEMPERATURE HOT WATER SUPPLYHTWS
MEDIUM-TEMPERATURE HOT WATER SUPPLYMTWS
FUEL OIL RETURNFOR
FUEL OIL SUCTIONFOS
FUEL OIL GAGEFOG
FUEL OIL DISCHARGEFOD
BOILER BLOWDOWNBBD
HIGH-PRESSURE CONDENSATEHPC
PUMPED CONDENSATEPC
MAKE UP WATERMUW
A.C. CONDENSATE DRAIND
REFRIGERANT HOT GASRHG
RL
RS
GLYCOL RETURNGR
REFRIGERANT LIQUID
REFRIGERANT SUCTION
GLYCOL SUPPLYGS
MPC
MPS
HWS
HWR
CHWS
CHWR
LPC
LPS
CWR
CWS
RHWS
RHWR
HPS
CHEM
SAN
HTWR
MTWR
FOV
HTWS
MTWS
FOR
FOS
FOG
FOD
BBD
HPC
PC
MUW
D
RHG
RL
RS
GR
GS
BLV
BFV
SCV
CBV
ACV
ACV
GV
GLV
MPV
PRV
T
FLG
RSV
PGV
RPBP
RELIEF OR SAFETY VALVE
PLUG VALVE
REDUCED PRESSURE BACKFLOW PREVENTOR
S-1
VAV
RETURN AIR GRILLE, REGISTER
EXHAUST AIR GRILLE, REGISTER
SUPPLY AIR 4 WAY DIFFUSER, REGISTER, GRILLE
SUPPLY AIR 3 WAY DIFFUSER, REGISTER, GRILLE
SUPPLY AIR 2 WAY DIFFUSER, REGISTER, GRILLE
SUPPLY AIR 2 WAY DIFFUSER, REGISTER, GRILLE
SUPPLY AIR 1 WAY DIFFUSER, REGISTER, GRILLE
ANCHOR
GUIDE
U
1. ALL HVAC GENERAL NOTES, SYMBOLS LISTS & DETAILS ARE TO BE
CONSIDERED AS APPLICABLE TO ALL HVAC DRAWINGS FOR THIS
PROJECT.
2. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND EXACT LOCATIONS
AND ARRANGEMENTS OF EXIST./NEW EQUIPMENT, DUCTWORK, PIPING
AND OTHER COMPONENTS SHALL BE DETERMINED IN THE FIELD WITH DUE
CONSIDERATION OF STRUCTURAL, ELECTRICAL AND ARCHITECTURAL
SYSTEMS. EXISTING STRUCTURAL SYSTEMS SHALL NOT BE MODIFIED
WITHOUT THE EXPRESS PERMISSION OF THE ENGINEER.
3. THE PROJECT SHALL BE PHASED IN ACCORDANCE WITH THE APPROVED
PHASING PLAN. THE CONTRACTOR SHALL OBTAIN APPROVAL FOR THE
SEQUENCING AND TIMING OF OPERATIONS PRIOR TO COMMENCING
WORK. SEE SPECIFICATIONS.
4. CONTRACTOR IS TO MAINTAIN SERVICE TO ROOMS OUTSIDE THE PROJECT
SCOPE OF WORK AND PHASING SCHEDULE. IF INTERRUPTION OF
SERVICE IS REQUIRED COORDINATE SHUTDOWN.
5. CARE SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT EXISTING
SYSTEMS AND SURFACES TO REMAIN. RESTORE DAMAGED AREAS THAT
ARE BEYOND THE SCOPE OF THIS CONTRACT TO THEIR ORIGINAL
CONDITION.
6. WHERE INDICATED ON THE DRAWINGS, REMOVE OR RELOCATE EXISTING
COMPONENTS AS REQUIRED TO ACCOMMODATE THE NEW WORK.
REMOVALS SHALL INCLUDE ALL ASSOCIATED OFF-SITE DISPOSAL COSTS.
7. COORDINATE REMOVALS AND RELOCATION'S INCLUDING SELECTIVE
CUTTING AND PENETRATIONS WITH ARCHITECTURAL, MECHANICAL,
STRUCTURAL AND ELECTRICAL CONTRACTORS.
8. MOST PARTITIONS ARE FULL HEIGHT AND REQUIRE UTILITIES
PENETRATIONS TO BE SEALED, SEE ARCHITECTURAL DWGS FOR
PARTITION HEIGHTS. UTILITIES SHOWN FOR CLARITY THAT MAY RUN
PARALLEL TO WALL PARTITIONS WILL REQUIRE LOCATING IN THE FIELD TO
MINIMIZE CONFLICT WITH PARTITIONS.
9. COORDINATE THE LOCATIONS OF ALL WALL MOUNTED TEMPERATURE
SENSORS WITH FINAL EQUIPMENT/FURNITURE LAYOUT.
10. MANUFACTURERS NAME & MODEL NUMBER ARE USED FOR DESCRIPTIVE
PURPOSES ONLY & ARE INTENDED TO INDICATE THE STANDARD OF
MATERIAL OR ARTICLES REQUIRED.
11. INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS AND GOOD PRACTICE NORMAL TO THE TRADE.
INSTALLATION SHALL INCLUDE PROVISIONS FOR ACCESS TO NORMAL
MAINTENANCE ITEMS SUCH AS BELTS, BEARINGS, FILTERS AND MOTORS.
PROVIDE ADEQUATE STRUCTURAL SUPPORTS AND SECURE MOUNTING
METHODS WITH PROVISIONS FOR VIBRATION ISOLATION AND EXPANSION
WHERE REQUIRED.
12. PROVIDE VOLUME DAMPERS DOWN STREAM OF VAV BOXES AT EACH
BRANCH FROM MAIN DUCTWORK AND DUCT RUNNOUTS. PROVIDE
OPPOSED BLADE DAMPERS AT EACH NECK TO AN INDIVIDUAL REGISTER
OR DIFFUSER IN SUPPLY, RETURN AND EXHAUST DUCTS IRRESPECTIVE
OF WHETHER OR NOT A DAMPER IS INDICATED ON THE PLANS.
13. DIFFUSER SIZES INDICATED ARE NECK SIZES. REGISTERS & GRILLES ARE
INDICATED AS NOMINAL SIZES.
14. PERFORM ALL TESTS BEFORE INSULATING.
15. PIPING AND DUCTWORK SHALL BE CONCEALED UNLESS OTHERWISE
NOTED.
16. INSTALLATION SHALL PERMIT ACCESSIBILITY FOR SERVICE AND/OR
REPLACEMENT OF EQUIPMENT PROVIDED. PROVIDE ACCESS PANELS TO
GAIN ACCESS TO SYSTEMS COMPONENTS THAT REQUIRE MAINTENANCE
ACCORDING TO MANUFACTURER'S LITERATURE.
17. PROVIDE DUCTWORK WITH OFFSETS AND TRANSITIONS AS REQUIRED TO
FIT UNDER STRUCTURAL STEEL OR OTHER OBSTRUCTIONS. FLAT OVAL OR
ROUND SIZES MAY BE USED INTERCHANGEABLY BY THE CONTRACTOR.
MAINTAIN DUCT CROSS SECTIONAL AREA. CHANGES SHALL BE ONLY IN
ACCORDANCE WITH APPROVED SHOP DRAWINS OR WRITTEN PERMISSION
OF THE VA PROJECT ENGINEER.
18. PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS & GUIDES
AS NECESSARY TO PREVENT UNDUE STRAIN ON PIPING.
19. SEE DETAILS & PIPING DIAGRAMS FOR ADDITIONAL VALVES & FITTINGS
NECESSARY FOR COMPLETE PIPING SYSTEM.
20. MECHANICAL CONTRACTOR TO COORDINATE ALL WORK WITH OTHER
BUILDING TRADES. SOME RELOCATION OF EXISTING UTILITIES MAY BE
NECESSARY TO ACCOMMODATE INSTALLATION OF NEW EQUIPMENT OR
DUCTWORK.
21. PROVIDE FIRE OR FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS &
WHERE REQUIRED BY APPLICABLE CODES FOR DUCTS & OPENINGS
THROUGH FLOORS, FIRE WALLS & FIRE PARTITIONS. DAMPERS SHALL BE
ENCLOSED IN #14 GAUGE STEEL SLEEVE. PROVIDE ACCESS DOORS
LOCATED SO THAT FUSIBLE LINK & OTHER DAMPER COMPONENTS MAY BE
INSPECTED REPLACED AND/OR SERVICED.
22. SEE SPECIFICATIONS FOR OTHER REQUIREMENTS.
23. AT THE END OF EACH WORKING DAY, THE CONSTRUCTION SITE SHALL BE
LEFT IN A CLEAN AND NEAT CONDITION.
24. FIELD VERIFY EXISTING EQUIPMENT, DUCTWORK AND PIPING PRIOR TO
REMOVAL OR REUSE. CONFIRM WITH HOSPITAL THAT ALL EQUIPMENT,
DUCTWORK AND PIPING DESIGNATED TO BE REMOVED IS NO LONGER IN
SERVICE PRIOR TO ITS REMOVAL.
25. EXISTING EQUIPMENT, DUCTWORK AND PIPING TO REMAIN IN SERVICE
SHALL BE INSPECTED. ANY EQUIPMENT FOUND TO BE INOPERABLE SHALL
BE REPORTED TO THE PROJECT ENGINEER.
26. INFILL ALL NEW OR EXISTING ABANDONED FLOOR SLAB PENETRATIONS
WITH GROUT, FULL THICKNESS OF SLAB. MAINTAIN 2 HR FIRE RATING. ALL
EXISTING CONCRETE FLOORS AND CHASES ARE 2 HOUR FIRE RATED.
27. FILL AND PATCH ALL OPENINGS IN WALLS WHERE CONDUITS, PIPES,
DUCTS ETC. ARE OR HAVE BEEN REMOVED WITH UL LISTED FIRE
ASSEMBLY APPROVED BY THE ARCHITECT. MAINTAIN 2 HR FIRE RATING
WHERE APPLICABLE.
28. ALL UNUSED (ABANDONED) DUCTWORK, PIPING AND EQUIPMENT
INDICATED TO BE REMOVED SHALL BE REMOVED AND CAPPED.
29. TIE-IN POINT LOCATIONS ARE APPROXIMATE. CONTRACTOR SHALL
DETERMINE EXACT LOCATIONS IN THE FIELD BASED ON EXISTING
CONDITIONS.
SMOKE DAMPERSD
3-WAY AUTOMATIC CONTROL
VALVE (MIXING PATTERN)
2-WAY AUTOMATIC CONTROL VALVE
SHADED DUCTWORK SHALL BE 16 GAUGE SHEETMETAL10x16
ROOF EXHAUST - EXISTING
ROOF EXHAUST - REMOVED
ROOF EXHAUST - NEW
EXPANSION JOINT
PIPE SIZE12"
G
PIPE SLOPE
PIPE SIZE, GANG
12"S UP
14"DN
1-1/2"
F&T
FLOAT & THERMOSTATIC TRAP
SYMBOLS DESCRIPTIONSABBREVIATIONS DESCRIPTIONSSYMBOLSSYMBOLS DESCRIPTIONSDESCRIPTIONSDESCRIPTIONS ABBREVIATIONS SYMBOLS DESCRIPTIONS
SYMBOLS DESCRIPTIONSABBREVIATIONS
DUCT MOUNTED SMOKE DETECTOR, MTD BY HVAC
CONTR. SUPPLIED AND WIRED BY ELECTRICAL CONTR.
TITLENUMBER
NOTE:
REFER TO ARCHITECTURAL DOCUMENTS FOR DEDUCT ALTERNATE ITEMS.
DIFFUSER SYMBOLS
MECHANICAL ALTERNATE LIST
DUCTWORK SYMBOLSGENERAL SYMBOLSPIPING SYMBOLSGENERAL ABBREVIATIONSHVAC GENERAL NOTES
LIMIT OF DEMOLITION
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg:
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
Dwg: of 217
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
198801108
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Legend & General Notes
10-MH001
ERDCMP 107
LC
-000
UTILITY
AL
ENGINEERINGUTILITY
OFFICE
BB-21
CLERICAL
OFFICE
OFFICE
UP
FD
FD
A1- 2
CORRIDOR
CLOSET
FIRE PROTECT.
ROOM
STORAGE
STORAGE
STORAGE
CORR
CORR
CORR
ROOM
WET MECH
8'-0"
8'-6"
8'-6"
8'-6"
1A1A
8F6
8F6
8F6
8F6
1A1
1A1
1A1
8F6
FB-05
FB-04
FB-03
FB-02
FCB-03
FC0-02
FC0-04
FB-01
AB-12A
AB-
MAIN ELECT.ROOM WET MECH.ROOM
STORAGE
ROOM
ENGIN. DEPT.
FIL
EX
M
M
E-2
E-E E-F
EF
(E)
RE-LOCATE EXISTING
DIFFUSER TO ALLOW
FOR NEW WORK.
24"x18" EA
36"x16" EA
1.9
EXISTING DUCTWORK TO BE REMOVED
(TYPICAL)
EXISTING LOUVER TO BE REMOVEDEXISTING LOUVER TO BE REMOVED
EXISTING DUCTWORK TO REMAIN (TYPICAL)
EXISTING FAN TO REMAIN
2 3 3.3 4 E-A E-B E-C
E-3
E-4
A
B
B.5
C
E-5D
D.6
EE-6
E-AA
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Ductwork Ground Floor Demo
10-MD101
ERDCMP 108
1/8" = 1'-0"1 HVAC Ductwork Ground Floor Demo
LC
000UTILITY
ICAL
ENGINEERINGUTILITY
OFFICE
BB-21
CLERICAL
OFFICE
OFFICE
FD
FD
A1- 2
CORRIDOR
CLOSET
FIRE PROTECT.
ROOM
STORAGE
STORAGE
STORAGE
CORR
CORR
CORR
ROOM
WET MECH
8'-0"
8'-6"
8'-6"
8'-6"
1A1A
8F6
8F6
8F6
8F6
1A1
1A1
1A1
8F6
FB-05
FB-04
FB-03
FB-02
FCB-03
FC0-02
FC0-04
FB-01
AB-12A
MAIN ELECT.ROOM WET MECH.ROOM
STORAGE
ROOM
ENGIN. DEPT.
E-2
E-E E-F
6"ø MPS
2"ø MPS
2"ø MPS
2" ø
MP
S
6"ø MPS
8"ø MPS
CONCRETE
PLATFORM TO BE
REMOVED (TYP 2)
3/4"ø MPC
2"ø MPC
4"ø LPC
8"ø LPC
3"ø LPC
4"ø MPC
EXISTING
CONDENSATE
PUMP TO REMAIN.
EXISTING FLASH
TANK TO REMAIN.
EXISTING 1-1/2"
MPC CAPPED
TEES.
EXISTING
DOMESTIC
WATER HEATERS
TO REMAIN
1.9
EXISTING PIPING TO REMAIN (TYPICAL)
2 3 3.3 4 E-A E-B E-C
E-3
E-4
A
B
B.5
C
E-5D
D.6
EE-6
E-AA
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Piping Ground Floor Demo
10-MD102
ERDCMP 109
1/8" = 1'-0"1 HVAC Piping Ground Floor Demo
1.91.31.50
EXISTING PIPING TO REMAIN
EXISTING FIN TUBE BASEBOARD HEATERS
TO BE REMOVED TO ACCOMMODATE NEW
CONNECTOR CORRIDOR
EXISTING FIN TUBE
BASEBOARD HEATERS TO
REMAIN
1 2 3 3.3 4 E-A E-B E-C
E-3
E-4
A
B
B.5
C
E-5D
D.6
EE-6
E.8
G
E-7
E-AA
ADJACENT BUILDING
(EXISTING)
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Piping First Floor Demo
10-MD103
ERDCMP 110
1/8" = 1'-0"1 HVAC Piping First Floor Demo
FEC
V t
V atc atc
PATIENT TLT
G-01
ELEV.
G-30
STAIR 1
GS-11
OFFICE
G-07
OFFICE
G-08
OFFICE
G-09
TMS
G-12
MRI WAIT
G-13
MRI PREP
G-18
MRI TOILET
G-15
GOWN 1
G-16
GOWN 2
G-17
READING
ROOM
G-29
OPEN BENCH
LAB
G-06
EEG
CONTROL RM
G-05
CORRIDOR
CORRIDOR
CR-G-02
CORRIDOR
CR-G-10
0" x1
" S A
72"x26" SA UP 60"x30" EA UP
EF
(E)
/1 10-MH100B /1 10-MH100B
30"x18" RA
16"x14" RA
"x1
6" R
A
18"x12" SA 18"x16" SA
"x1
8" S
A
"x2
6" S
A
S-2
S-3
(TYP 2)
R-5
S-3
E-4
EEG TEST
G-03
EXERCISE
ROOM
G-04
S-2
S-2
R-2
R-2
E-1
R-5
S-2
R-2
R-2
S-2
S-2
R-2
R-2
S-2
R-2
R-1
R-1
AC
S-2
S-2
S-2
E-1 100 S-3
S-3
RHC
G1
E-2
R-4
VVR
VVR
VVR
VVR
004 VVR
VVR
VVR
VVR
VVR
18"x18" SA18"x16" SA
30"x16" RA
8"ø RA10"x10" RA
"x1
0" R
A
"x1 2"
R A
"x1
2" R
A
16"x12" RA
8"ø SA
10"x10" SA
8"ø SA
8"ø SA
"x1
0" S
A
8"ø RA
8"ø RA
"x1
0" S
A
9"ø SA
12"x12" SA
8" ø
SA
"ø S
A
7" ø
SA
7"ø RA
8"ø RA
6"ø RA
6" ø
RA
8" ø
SA
8" ø
RA
"x8
" R A
"x1
4" R
A
8"ø SA
"x1
2" R
A
10"ø SA
10"ø SA
"ø
S A
8"ø SA
8"ø RA
"x8
" R A
"x1
0" S
A
14"x12" RA
16"x10" EA
"x1
4" E
A
"x1
6" R
A
"x8
" E A
8" ø
EA
6"ø EA
6" ø
EA
F
F
F
F
1.91.31.50
BALANCE TO
640 CFM
"x1
0" E
A
14"x14" EA UP
"x1
0" E
A
FCU
E-3
FIRE DAMPER IN
VERTICAL DUCTWORK
F
ACCESS DOOR
48"x48" EA
FIRE DAMPER IN
VERTICAL DUCTWORK
F
1 2 3 3.3 4 E-A E-B E-C
E-4
A
B
B
C
E-5 D
30"x60" EA
"x1
8" S
A
T
AC-2 TEMPERATURE
SENSOR LOCATED IN
RETURN DUCTWORK14
"x1 4"
S A
"x1
4" R
A
"x1 2"
R A
14"x14" EA
"x1
0" S
A
8"ø SA
8" ø
SA
S-2
277V277V4X4 JUNCTION BOX, 277V, 1PH,
EMERGENCY POWER, DEDICATED
15 AMP CIRCUIT, ABOVE CEILING BY
E.C. FOR CONTINUATION BY ATC
CONTRACTOR FOR CONTROLS.
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Ductwork Ground Floor Plan A
10-MH100A
ERDCMP 111
1/4" = 1'-0"1 HVAC Ductwork Ground Floor Plan A
M
V M
V atc
V atc atc
MRI PREP
G-18
MRI TOILET
G-15
GOWN 1
G-16
GOWN 2
G-17
CONTROL
ROOM
G-19
MRI EXAM
ROOM
G-20
SIEMENS
EQUIPMENT
ROOM
G-21
STAIR 2
GS-22
ELEC.
CLOSET
G-23
STAFF TLT
G-24
HKP
G-25
READING
ROOM
G-29
IT-DATA
ROOM
G-26
OPEN BENCH
LAB
G-06
EEG
CONTROL RM
G-05
CORRIDOR
CORRIDOR
CR-G-27
0" x1
" S A
EF
(E)
12"x12" SA
10"ø SA
10"ø SA
"x1
2" S
A
12"x12" SA
"ø
S A
"ø
S A
AL AL
AL
AL
AL
AL
/1 10-MH100A/1 10-MH100A
18"x30" RA UP
30"x18" RA
16"x14" RA
"x1
6" R
A
S-2
S-2
S-3
S-3
"x2
6" S
A
S-2
R-3
E-1
E-1
R-3
S-2
S-3
(TYP 2)
R-5
S-3
E-4
EXERCISE
ROOM
G-04
R-1
AC
S-2
S-3
S-3
RHC
G1
S-2
R-3
R-4
S-3
VVR
VVR
VVR
VVR
VVR
VV
VVR
"x1
4" S
A
12"x12" SA
18"x18" SA18"x16" SA
"x1
6" S
A
30"x16" RA
"x1
2" R
A
16"x12" RA
"x1
0" S
A
6"ø RA
6" ø
RA
"x1
2" R
A
10"ø SA
10"ø SA
"ø
S A
"x8
" S A
SG-2
10"ø SA
9"ø SA
8"ø SA
"x8
" R A
"x1
0" S
A
8"ø RA
14"x12" RA
8"ø RA
14"x12" EA
"x8
" E A
12"x10" EA
"x1 0"
E A
16"x10" EA
"x1
4" E
A
"x1
6" R
A E-3
6" ø
EA
6"ø EA
"x8 " E
A
F
F
F
F
1.91.31.50
14"x12" EA UP
BALANCE TO
640 CFM
R-8
(TYP 2)
T
"x1
0" E
A
14"x14" EA UP
"x1
0" E
A
FCU
W-3
F
48"x48" EA
1 2 3 3.3 4 E-A E-B E-C
E-5 D
D.6
E E-6
E.8
G
E-7
E-AA
30"x60" EA
ALL DUCTWORK,
DIFFUSERS, GRILLES
AND OTHER
EQUIPMENT WITHIN
THE MRI EXAM ROOM
MUST BE
CONSTRUCTED OF
NON-FERROUS
MATERIALS
12"x12" RA
"x1
8" S
A
"x8
" S A
T
AC-2 TEMPERATURE
SENSOR LOCATED IN
RETURN DUCTWORK
RF WAVEGUIDE MUST BE
INSTALLED WHEREVER DUCT
ENTERS THE RF SHIELD.
REFER TO ETS LINDGREN DWGS
RF WAVEGUIDE MUST BE
INSTALLED WHEREVER DUCT
ENTERS THE RF SHIELD. REFER
TO ETS LINDGREN DWGS.
"x1
4" S
A
"x1
4" R
A
"x1 2"
R A
"x1
2" R
A
24"x12" RA
14"x14" EA
8"ø SA
8" ø
SA
S-2
AL
AL
PROVIDE DIELECTRIC
CONNECTOR TO SEPARATE
ALUMINUM DUCT INSIDE MRI
EXAM ROOM FROM
GALVANIZED STEEL
(TYPICAL)
277V277V4X4 JUNCTION BOX, 277V, 1PH,
EMERGENCY POWER, DEDICATED
15 AMP CIRCUIT, ABOVE CEILING BY
E.C. FOR CONTINUATION BY ATC
CONTRACTOR FOR CONTROLS.
4X4 JUNCTION BOX, 120V, 1PH, ABOVE
CEILING BY E.C. FOR CONTINUATION BY
ATC CONTRACTOR FOR CONTROLS.
(TYPICAL UNLESS NOTED OTHERWISE)
S-5
(TYP 3)
R-9
(TYP 3)
"x2
0" S
A
24"x24" SA DN
TO DIFFUSER
(TYP 3)
NOTE: CEILING
PLENUM RETURN. ALL
CABLE MUST BE
PLENUM-RATED.
AC
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Ductwork Ground Floor Plan B
10-MH100B
ERDCMP 112
1/4" = 1'-0"1 HVAC Ductwork Ground Floor Plan B
FECFEC
PATIENT TLT
G-01
ELEV.
G-30
STAIR 1
GS-11
OFFICE
G-07
OFFICE
G-08
OFFICE
G-09
TMS
G-12
MRI WAIT
G-13
MRI PREP
G-18
MRI TOILET
G-15
GOWN 1
G-16
GOWN 2
G-17
CONTROL
ROOM
G-19
READING
ROOM
G-29
OPEN BENCH
LAB
G-06
EEG
CONTROL RM
G-05
CORRIDOR
CORRIDOR
CR-G-02
CORRIDOR
CR-G-10
AC
/1 10-MH101B /1 10-MH101B
VVR
VVR
VVR
VVR
VVR
006VVR
VVR
VVR
VVR
EEG TEST
G-03
1.91.31.50
FCU
E-3
3/4"ø HWS 3/4"ø HWR
1 1 /2" ø
HW
R 1 1
/2" ø
HW
S
1 1 /4" ø
HW
R 1 1
/4" ø
HW
S
1 1/4"ø HWS 1 1/4"ø HWR
3/4"ø HWS 3/4"ø HWR
3/4 "ø
H W
R 3/4
"ø H
W S
3/4 "ø
H W
S 3/4
"ø H
W R
1 1 /4" ø
HW
S 1 1
/4" ø
HW
R
1"ø HWS 1"ø HWR
T
T
T
T
T T
T
T
T
1 2 3 3.3 4 E-A E-B E-C
E-4
A
B
B
C
E-5 D
1"ø CHWR 1"ø CHWS
3/4"ø HWR 3/4"ø HWS
1 /
-M H1
C
3-WAY CONTROL VALVE
RHC-G1
T
T
AC-2 TEMPERATURE
SENSOR LOCATED IN
RETURN DUCTWORK
NOTE: PUMP
CONDENSATE TO
HOUSEKEEPING
SINK.
PROVIDE BASE OF
RISER DRIP TRAP.
4.8 KW ELECTRIC WALL
HEATER. QMARK CWH3000
OR EQUAL. 277V/1PH
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Piping Ground Floor Plan A
10-MH101A
ERDCMP 113
1/4" = 1'-0"1 HVAC Piping Ground Floor Plan A
FEC FEC
MRI PREP
G-18
MRI TOILET
G-15
GOWN 1
G-16
GOWN 2
G-17
CONTROL
ROOM
G-19
MRI EXAM
ROOM
G-20
SIEMENS
EQUIPMENT
ROOM
G-21
STAIR 2
GS-22
ELEC.
CLOSET
G-23
STAFF TLT
G-24
HKP
G-25
READING
ROOM
G-29
IT-DATA
ROOM
G-26
OPEN BENCH
LAB
G-06
EEG
CONTROL RM
G-05
CORRIDOR
CORRIDOR
CR-G-27
4"ø HWS
1 1/2"ø MPC 1 1/2"ø MPS
4"ø HWR
AC
/1 10-MH101A
EXISTING MRI CHILLER SHALL
BE MOVED TO THIS LOCATION.
INSTALL ON CONCRETE PAD
2"ø CHWR
2"ø CHWS
VV
VVR
VVR
VVR
VVR
VVR
VVR
1.91.31.50
FCU
W-3
3/4"ø HWS 3/4"ø HWR
1 1 /2" ø
HW
R 1 1
/2" ø
HW
S
1 1 /2" ø
HW
S 1 1
/2" ø
HW
R
1 1/2"ø HWR 1 1/2"ø HWS
1 1 /4" ø
HW
S 1 1
/4" ø
HW
R
4"ø HWR 4"ø HWS
4"ø HWR 4"ø HWS
1"ø HWR 1"ø HWS
4" ø
CH
W
S 4" ø
CH
W R
T
T
T
T
T
T
T
T
4" CHWS RISER TO UPPER
FLOORS AND AHU-1
4" CHWR RISER FROM
UPPER FLOORS AND AHU-1
CH
CH
MRI
1 2 3 3.3 4 E-A
E-5 D
D.6
E E-6
E.8
G
E-7
E-AA
CH-1 CHILLED WATER SUPPLY &
RETURN PIPING SHALL GO DOWN
OUTSIDE OF BUILDING
UNDERGROUND FROM THIS POINT
TO CH-1.
4"ø CHWS
4"ø CHWR
1 1/4"ø CHWS 1 1/4"ø CHWR
1"ø HWR 1"ø HWS
UNDERGROUND
UNDERGROUND
1"ø CHWR 1"ø CHWS
3/4"ø HWR 3/4"ø HWS
1 /
-M H1
C
1 /
-M H1
C
CONNECT TO SIEMENS HEAT EXCHANGER
NO FERROUS MATERIALS ARE
PERMITTED WITHIN THE MRI EXAM
ROOM
3-WAY CONTROL VALVE
3/4"ø HWR 3/4"ø HWS
RHC-G1
T
Emergency
__EF-1
Emergency
__EF-1
EMERGENCY
SWITCH FOR
EF-1
T
AC-2 TEMPERATURE
SENSOR LOCATED IN
RETURN DUCTWORK
MRI SUITE NOTES:
(1) THE QUENCH VENT SHALL BE FABRICATED OF NON-MAGNETIC WELDED STAINLESS STEEL OR ALUMINUM.
REFER TO SPECIFICATION 232113. QUENCH VENT PIPE MUST BE ROUTED IN THE MOST DIRECT ROUTE TO ROOF AS SHOWN. RE-LOCATE ANY EXISTING UTILITIES THAT ARE IN THE WAY. DO NOT ADD ELBOWS OR OFFSETS THAT ARE NOT SHOWN ON DRAWINGS. ALL OTHER TRADES SHALL COORDINATE THEIR WORK TO ACCOMODATE QUENCH VENT ROUTE. INSULATE QUENCH VENT ALONG ITS ENTIRE LENGTH IN ACCORDANCE WITH MRI MANUFACTURER'S RECOMMENDATIONS. QUENCH VENT MUST WITHSTAND MAXIMUM PRESSURE OF
6.5 PSI. PROVIDE RIGID SUPPORTS TO BUILDING STRUCTURE AS FOR PIPE, NOT DUCT, BASED ON WEIGHT OF VENT.
ALL ELBOWS SHALL BE SMOOTH WALLED AND HAVE A CENTERLINE TO INTERNAL PIPE DIAMETER RATIO OF 1.5 TO 5.0.
(2) INSTALL QUENCH VENT WAVEGUIDE (PROVIDED BY ETS LINDGREN) AT RF SHIELD PENETRATION. INSTALL DIALECTRIC ISOLATION, ONE INSIDE RF SHIELD AND ONE OUTSIDE, PER MRI MANUFACTURER'S RECOMMENDATIONS.
(3) CONNECTION TO MAGNET MUST BE MADE BY BOLTING VENT ADAPTER TUBE SECTION (SUPPLIED BY SIEMENS)
DIRECTLY TO FLANGE.
(4) INSTALL STAINLESS STEEL BELLOWS RATED TO 6.5 PSI AND -451 DEG F WHERE NOTED ON DRAWINGS.
BELLOWS SHALL BE DESIGNED PER SPECIFICATION 232113.
(5) AT 3RD FLOOR OFFSET, PROVIDE 3/4" DRAIN PIPE CONNECTION WITH VALVE AND HOSE CONECTION AND CAP
AT BASE OF ELBOW TO ROOF.
(6) PROVIDE HVAC WAVEGUIDE AIR VENT AT EVERY DUCT PENETRATION OF THE RF SHIELDING. REFER TO ETS LINDGREN DRAWINGS FOR PENETRATION DETAILS. PROVIDE DIELECTRIC UNION/CONNECTOR IN DUCT OUTSIDE
OF RF SHIELDING PENETRATIONS.
COORIDINATE
BURRIED DEPTH
WITH CIVIL
SEE CRYOGEN VENT DETAIL.
INSTALL FLEXIBLE BELLOWS
PER SPEC 232113 BETWEEN
EACH RIGID SUPPORT
TO BUILDING STRUCTURE.
SEE ALSO SIEMENS DRAWINGS.
MSI
G
NOTE: PUMP
CONDENSATE TO
HOUSEKEEPING
SINK.
NOTE: PUMP
CONDENSATE TO
HOUSEKEEPING
SINK.
1 1/2" MPC UP
1 1/2" MPS UP
PROVIDE BASE OF
RISER DRIP TRAP.
PROVIDE BASE OF
RISER DRIP TRAP.
AC
NOTE: CEILING
PLENUM RETURN. ALL
CABLE MUST BE
PLENUM-RATED.
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Piping Ground Floor Plan B
10-MH101B
ERDCMP 114
1/4" = 1'-0"1 HVAC Piping Ground Floor Plan B
-000
D2
UTILITY
BIOMEDICAL
ENGINEERINGUTILITY
OFFICE
BB-21
CLERICAL
OFFICE
OFFICE
S U
FD
FD
A1- 2
CORRIDOR
LOBBY
ELEVATOR
CLOSET
FIRE PROTECT.
ROOM
STORAGE
STORAGE
STORAGE
CORR
CORR
CORR
ROOM
WET MECH
REAWAY 1
AREAWAY 2
8'-0"
8'-6"
8'-6"
8'-6"
1A1A
8F6
8F6
8F6
8F6
1A1
1A1
1A1
8F6
8F6
8F6
FB-05
FB-04
FB-03
FB-02
FCB-03
FC0-02
FC0-04
FB-01
AB-12A
AB-12B
MAIN ELECT.ROOM WET MECH.ROOM
STORAGE
ROOM
ENGIN. DEPT.
EXIST.
FILES
EXIST.
-000
D2
UTILITY
BIOMEDICAL
ENGINEERINGUTILITY
OFFICE
BB-21
CLERICAL
OFFICE
OFFICE
S U
FD
FD
A1- 2
CORRIDOR
LOBBY
ELEVATOR
CLOSET
FIRE PROTECT.
ROOM
STORAGE
STORAGE
STORAGE
CORR
CORR
CORR
ROOM
WET MECH
REAWAY 1
AREAWAY 2
8'-0"
8'-6"
8'-6"
8'-6"
1A1A
8F6
8F6
8F6
8F6
1A1
1A1
1A1
8F6
8F6
8F6
FB-05
FB-04
FB-03
FB-02
FCB-03
FC0-02
FC0-04
FB-01
AB-12A
AB-12B
MAIN ELECT.ROOM WET MECH.ROOM
STORAGE
ROOM
ENGIN. DEPT.
EXIST.
FILES
EXIST.
E-2
E-E E-F
E-B E-C
E-3
E-4
A
B.5
C
E-5D
D.6
EE-6
4"ø HWR 4"ø HWS 1 1/2"ø MPS
1 1/2"ø MPC
CONTRACTOR IS
RESPONSIBLE FOR PROVIDING
EXPANSION LOOPS AND
ANCHORS WHERE NEEDED.
INSTALL PIPES WITHIN
LARGER PIPES, OR
PROVIDE SIMILAR MEANS
OF POSITIVE LEAK
PROTECTION WHERE
PIPES CROSS DATA
ROOM.
HX
P 1P
HX
REFER TO STEAM AND HOT
WATER GENERATION
SCHEMATIC AND RELATED
DETAILS FOR WORK IN THIS
AREA.
1 /
-M H1
B
1 /
-M H1
B
4"ø HWR 4"ø HWS 1 1/2"ø MPS 1 1/2"ø MPC
EXPOSED:
MOUNT HIGH AS POSSIBLE.
FLASH TANK (E)
COND PUMP (E)
6" MPS (E)
NEW HEATING HOT WATER SYSTEM
MAKEUP WATER SHALL BE FROM
EXISTING MAKEUP WATER TO
EXISTING HEATING HOT WATER
SYSTEM.
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Piping Ground Floor Plan C
10-MH101C
ERDCMP 115
1/8" = 1'-0"1 HVAC Piping Ground Floor Plan C
F F FF
atc atc
TEAM
LEADER
OFFICE
1-14
TEAM
LEADER
OFFICE
1-13
STAIR 1
1S-11
ELEVATOR
G-30
PATIENT
TOILET
1-10
CONFERENCE
ROOM
1-16
EXAM ROOM
1-09
BLOOD
DRAW
1-08
PATIENT
TOILET
1-07
CONSULT
1-05
CONSULT
1-04
NOURISH
1-06
WAITING
1-02
CORRIDOR
CR-1-23
CORRIDOR
CR-1-15
LAB MODULE
1-17
CONSULT
1-38
CONSULT
1-39
60"x30" EA UP
72"x26" SA UP
10"x8" SA
10"x8" RA
6" ø
RA
10"x8" SA7"ø SA
7" ø
SA
8"ø SA
VVR
R-1
S-1
R-1
S-1
VVR
VVR
116 S-1
/1 10-MH102B /1 10-MH102B
CORRIDOR
CR-1-33
"x2
6" R
A
26"x48" RA UP
48"x26" SA UP
"x8
" S A
"x1
2" S
A
"x1 6"
S A
26"x26" RA
7"ø SA S-1
R-2
28"x12" RA
R-2
(TYP 2)
R-4
(TYP 2)
R-4
(TYP 2)
R-2
7"ø RA
"x1
8" R
A
6"ø RA
E-2
S-1
8" ø
SA
VVR
VVR
VVR
10"x10" SA
R-4
8" ø
SA
8" ø
SA
SL-2
(TYP 2)
SL-2
(TYP 2)
8" ø
SA
8" ø
SA
10"x10" SA
R-4
VVR
VVR
VVR
SL-2
(TYP 3)
SL-2
(TYP 3)
R-2
S-2
12"x12" RA
"x1
2" R
A
7"ø RA
R-2
S-1
"x1
4" S
A
"x1 4"
S A
10"x10" SA
9"ø SA
9"ø SA
9"ø SA
9"ø SA
9" ø
SA
12"x12" RA
9" ø
SA 20"x12" RA 28"x12" RA
"x8
" R A
"x1
0" E
A
12"x12" RA
12"x6" RA
"x6
" R A
"x6
" R A
"x6
" R A
14"x12" RA 20"x12" RA
12"x10" RA
8"x8" RA
LINEN
SUPPLY
1-36
SL-2
(TYP 2)
12"x10" SA
14"x10" SA
7" ø
SA
S-1
7" ø
SA
8" ø
SA
S-2
7" ø
SA
VVR
S-2
8"x8" SA
8" ø
SA
20"x12" RA
8" ø
EA
8"ø SA
"x1
0" E
A
E-1
CORRIDOR
CR-1-01
1.91.31.50
R-2
6"ø EA
14"x18" EA UP
8" ø
SA
8" ø
SA
8" ø
SA
8" ø
SA
8" ø
SA
SL-2
(TYP 5)R-5
(TYP 2)
"x1
6" R
A
7"ø SA
S-1
R-1
6" ø
RA
8"x8" RA 6"ø RA
10"x8" SA
18"x12" SA
FCU
2E
SURFACE MOUNT AND
RECESS UNIT FCU-2E
1 2 3 3.3 4 E-A E-B E-C
E-4
A
B
B
C
E-5 D
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Ductwork First Floor Plan A
10-MH102A
ERDCMP 116
1/4" = 1'-0"1 HVAC Ductwork First Floor Plan A
F
F
F FF
F atc atc
EXAM ROOM
1-09
BLOOD
DRAW
1-08
CORRIDOR
CR-1-24
CORRIDOR
CR-1-25
CORRIDOR
CR-1-23
LAB MODULE
1-17
LAB MODULE
1-18
CONSULT
1-19
CONSULT
1-20
HKP
1-26
CLOSET
1-21
OFFICE
1-27 OFFICE
1-28
STAIR 2
1S-22
ELEC.
CLOSET
1-30
MENS STAFF
TOILET
1-31
WOMENS
STAFF
TOILET
1-32
CONSULT
1-38
CONSULT
1-39
16" MRI QUENCH
VENT
VVR
/1 10-MH102A/1 10-MH102A
CORRIDOR
CR-1-33
"x2
6" S
A
42"x18" SA
"x2
6" R
A
26"x48" RA UP
48"x26" SA UP
"x8
" S A
"x1
6" S
A
SG-2
26"x26" RA
VVR
VVR
"x8
" S A
VVR
S-1
7"ø SA S-1
R-2
E-3
28"x12" RA
R-4
(TYP 2)
R-4
(TYP 2)
"x1
8" R
A
6"ø RA
VVR
VVR
SL-2
(TYP 3)
SL-2
(TYP 3)
R-2
12"x12" RA
S-1
40"x18" SA
"x1 6"
S A
"x1
6" S
A
"x1 4"
S A
9"ø SA
9"ø SA
9" ø
SA
12"x12" RA
12"x12" SA
9" ø
SA
9"ø SA
9"ø SA
"x1
2" R
A
20"x12" RA 28"x12" RA
"x8
" R A
"x8
" R A
12"x12" SA
6" ø
EA
14"x8" EA
10"x8" SA
6" ø
EA
"x1
0" E
A
12"x12" RA
12"x6" RA
"x6
" R A
S-2
E-1
E-1
42"x18" SA
12"x10" SA
8"ø SA
"x1
0" S
A 8" ø
SA
SL-2
SL-2
VVR
VVR
118VVR
VVR
SL-2
OFFICE
1-29
LINEN
SUPPLY
1-36
8"ø SA
10"x10" SA
8" ø
SA
SL-2
S-1
8" ø
SA
R-2
R-2
10"x10" RA8"ø RA
8" ø
RA
R-2
R-2
R-2
8"ø RA
"x1
2" R
A
8"ø RA
8"ø RA
6" ø
EA
6" ø
EA
E-1
R-2
7"ø RA
7" ø
SA
7"ø SA
"x1
0" S
A
VVR
S-2
8"x8" SA
8" ø
SA
"x1
0" E
A
VV
119 S-1
E-2
1.91.31.50
R-2
8"ø EA
14"x12" EA UP
14"x18" EA UP
12"x12" EA UP
FCU
2W
"x1
2" E
A
1 2 3 3.3 4 E-A E-B E-C
E-5 D
D.6
E E-6
E.8
G
E-7
E-AA
"x8
" E A
12"x8" SA
10"ø SA
S-2
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Ductwork First Floor Plan B
10-MH102B
ERDCMP 117
1/4" = 1'-0"1 HVAC Ductwork First Floor Plan B
TEAM
LEADER
OFFICE
1-14
STAIR 1
1S-11
ELEVATOR
G-30
EXAM ROOM
1-09
PATIENT
TOILET
1-07
WAITING
1-02
CORRIDOR
CR-1-23
LAB MODULE
1-17
LAB MODULE
1-18
CONSULT
1-38
CONSULT
1-39
1"ø HWS 1"ø HWR
1"ø HWS 1"ø HWR
RADIANT SLAB HEATING
SYSTEM, 16 MBH:
CIRCULATING PUMP, 3-WAY
MIXING VALVE, AND
MANIFOLD IN CABINET.
/1 10-MH103B /1 10-MH103B
EXTENT OF
RADIANT SLAB
HEATING SYSTEMVVR
VVR
VVR
VVR
VVR
VVR
VVR
VVR
CONSULT
1-03
LINEN
SUPPLY
1-36
CORRIDOR
CR-1-01
TEAM
LEADER
OFFICE
1-13
PATIENT
TOILET
1-10
CONFERENCE
ROOM
1-16
BLOOD
DRAW
1-08
PATIENT
TOILET
1-07
CONSULT
1-05
CONSULT
1-04
NOURISH
1-06
CORRIDOR
CR-1-23
CORRIDOR
CR-1-15
CONSULT
1-03
LINEN
SUPPLY
1-36
CORRIDOR
CR-1-01
1.91.31.50
1" HWS & HWR UP TO
SECOND FLOOR CEILING
1" HWS & HWR UP TO
SECOND FLOOR CEILING
COPY/RECORDS
STORAGE
1-40
KITCHEN
1-34
FCU
2E
1 1/4"ø HWR 1 1/4"ø HWS
1" ø
HW
S
1" ø
HW
R
1 1 /2" ø
HW
R 1 1
/2" ø
HW
S
1" ø
HW
R
1" ø
HW
S
VVR
VVR
3/4 "ø
H W
S 3/4
"ø H
W R
1"ø HWR 1"ø HWS
1 1 /2" ø
HW
R 1 1
/2" ø
HW
S
1"ø HWR 1"ø HWS
1" ø
HW
S
1" ø
HW
S
1" ø
CH
W
S 1" ø
CH
W R
1" ø
CH
W
S 1" ø
CH
W R
1" ø
CH
W
S 1" ø
CH
W R
T
T
T
T
T
T T
T
T T
T T
1 1 /2" ø
HW
R 1 1
/2" ø
HW
S 1 1/4"ø HWR
1 1/4"ø HWS
4" DOWN
FLUSH MOUNT
VERTICAL RECESS
1 2 3 3.3 4 E-A E-B E-C
E-4
A
B
B.5
C
E-5 D
DRAIN TO INDIRECT WASTE
(TYPICAL)
3-WAY
CONTROL
VALVE
3-WAY
CONTROL
VALVE
RP
RP
RP
T
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Piping First Floor Plan A
10-MH103A
ERDCMP 118
1/4" = 1'-0"1 HVAC Piping First Floor Plan A
FEC FEC
EXAM ROOM
1-09
CORRIDOR
CR-1-25
CORRIDOR
CR-1-23
LAB MODULE
1-17
LAB MODULE
1-18
CONSULT
1-20
HKP
1-26
CLOSET
1-21
STAIR 2
1S-22
ELEC.
CLOSET
1-30
MENS STAFF
TOILET
1-31
WOMENS
STAFF
TOILET
1-32
CONSULT
1-38
CONSULT
1-39
/1 10-MH103A/1 10-MH103A
4" HWR UP
4" HWS UP
VVR
VVR
VVR
VVR
VVR
VVR
VVR
VVR
VVR
VVR
VV
VVR
LINEN
SUPPLY
1-36
OFFICE
1-29
CORRIDOR
CR-1-24
CORRIDOR
CR-1-23
CONSULT
1-19
CONSULT
1-20
CLOSET
1-21
OFFICE
1-27
OFFICE
1-28
ELEC.
CLOSET
1-30
LINEN
SUPPLY
1-36
OFFICE
1-29
CORRIDOR
CR-1-33
1.91.31.50
COPY/RECORDS
STORAGE
1-40
KITCHEN
1-34
IT-DATA
ROOM
1-41
1 1 /2" ø
HW
R 1 1
/2" ø
HW
S
1" ø
HW
R
1" ø
HW
S
FCU
2W
1 1 /2" ø
HW
R 1 1
/2" ø
HW
S
2"ø HWR 2"ø HWS
3/4"ø HWS 1"ø HWS 3/4"ø HWR 1"ø HWR
1" ø
HW
S
1" ø
HW
R
1" ø
HW
S
1" ø
HW
S
1 1/4"ø HWR 1 1/4"ø HWS1 1/4"ø HWS
1 1/4"ø HWR
1 1 /2" ø
HW
R 1 1
/2" ø
HW
S
1" ø
HW
S
1" ø
HW
R
1"ø HWR 1"ø HWS
1" ø
CH
W
S 1" ø
CH
W R
1"ø CHWS 1"ø CHWR
1" ø
CH
W
S 1" ø
CH
W R
1" ø
CH
W
S 1" ø
CH
W R
1"ø HWS 1"ø HWR
T
T
T T
T
T
T
T
T
T
T
4" DOWN
4" DOWN
FLUSH MOUNT
VERTICAL RECESS
1 2 3 3.3 4 E-A E-B E-C
E-5 D
D.6
E E-6
E.8
G
E-7
E-AA
DRAIN TO
INDIRECT WASTE
3-WAY
CONTROL
VALVE
RP
RP
T
SEE CRYOGEN VENT DETAIL.
INSTALL FLEXIBLE BELLOWS
PER SPEC 232113 BETWEEN
EACH RIGID SUPPORT
TO BUILDING STRUCTURE.
SEE ALSO SIEMENS DRAWINGS.
MSI
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg: of 217
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
A
B
C
D
E
F
VA FORM 08-6231, OCT 1978
on e e ig on e q ua rte r i on e h al f th re e e ig th re e q ua rte rs i
6" on e i
6" on e h a lf i nc f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
198801108
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
03-31-2016
HVAC Piping First Floor Plan B
10-MH103B
ERDCMP 119
1/4" = 1'-0"1 HVAC Piping First Floor Plan B
FF
atc atc
PATIENT
TOILET
2-02
ELEVATOR
G-30
STAIR 1
2S-11
TEAM
LEADER
OFFICE
2-06
TEAM
LEADER
OFFICE
2-07
LAB MODULE
2-08
LAB MODULE
2-09
LAB MODULE
2-11
CONSULT
2-04
CORRIDOR
CR-2-05
CORRIDOR
CR-2-10
CORRIDOR
CR-2-01
72"x26" SA DN
SUPPLY AIR LOUVER. 17'-
0"x7'-0" ACTIVE AREA.
EXHAUST AIR LOUVER.
17'-0"x7'-0" ACTIVE AREA.
BLANK OFF UNUSED
PORTION OF LOUVER
/1 10-MH104B /1 10-MH104B
IT-DATA
ROOM
2-23
CONSULT
2-24
LAB
2-25
CONSULT
2-26
OPEN
OFFICE
2-03
"x2
6" R
A
26"x26" RA
8" ø
RA
6"ø RA
"x8
" S A S-1
"x6
" S A
8"ø SA
8"ø SA
S-1
S-1
VVR
12"x10" SA
9" ø
SA
9" ø
SA
R-5
28"x12" RA
R-4
(TYP 2)
R-4
(TYP 2)
R-4
(TYP 2)
R-2
7"ø RA
"x1
8" R
A
6"ø RA
E-2
S-2
8" ø
SA
VVR
VVR
VVR
12"x10" SA
R-4
8" ø
SA
8" ø
SA
SL-2
(TYP 2)
SL-2
(TYP 2)
8" ø
SA
8" ø
SA
12"x10" SA
R-4
VVR
VVR
VVR
SL-2
(TYP 3)
SL-2
(TYP 3)
SL-2
(TYP 3)
R-1
R-1
S-2
12"x12" RA 14"x8" RA
"x1
2" R
A
6"ø RA
R-1
S-1
7"ø SA
S-2
(TYP 2)
"x1
4" S
A
"x1 4"
S A
14"x12" SA
9"ø SA
9"ø SA
9"ø SA
9"ø SA
9"ø SA
9" ø
SA
14"x12" RA
9" ø
SA 20"x12" RA 28"x12" RA
"x8
"…
This is the start of the file's text. The full file is on GovTribe.