EQUIPMENT SPECIFICATIONS CHECKLIST.pdf
PDF 108 KB Posted
- Attached to
- Q522--Mobile MRI Service Federal contract opportunity
- Solicitation number
- 36C26323Q0983
About this file
This document is an equipment specifications checklist for a mobile MRI service solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23. The solicitation requires bidders to specify whether various MRI scanner models, coils, software applications, and accessories would be included in their proposed mobile MRI trailer. Required equipment includes an Siemens Aera 1.5T MRI scanner with various coil options, a pressure injector, planning suite applications, and TimCT capability. The solicitation also requires bidders to specify whether an ADA-compliant dressing room with lockable storage and necessary staffing of an MR tech and two assistants would be included.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| REVISED PRICE AND COST SCHEDULE REVISED.pdf | ||
| AMENDMENT 0002 36C26323Q0983 0002.pdf | ||
| 36C26323Q0983 0002_1.docx | DOCX document | |
| REVISED SF1449 SOLICITATION DOCUMENT 36C26323Q0983 REVISED.pdf | ||
| SF30 36C26323Q0983 0001 RESPONSE TO QUESTIONS.pdf | ||
| 36C26323Q0983 0001_1.docx | DOCX document | |
| D.6 ATTACHMENT SCA WAGE DETERMINATION 2015-4945.pdf | ||
| D.4 ATTACHMENT SUBCONTRACTING LIMITATION ACKNOWLEDGEMENT.pdf | ||
| D.2 ATTACHMENT ORGANIZATIONAL CONFLICT CERTIFICATION.pdf | ||
| SF1449 SOLICITATION DOCUMENT 36C26323Q0983.pdf | ||
| 36C26323Q0983_1.docx | DOCX document | |
| D.5 ATTACHMENT QUALITY ASSURANCE SURVEILLANCE PLAN.pdf | ||
| D.1 ATTACHMENT IMMIGATION CERTIFICATION.pdf | ||
| D.3 ATTACHMENT RECORDS MANAGEMENT OBLIGATIONS.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL FACTOR – EQUIPMENT SPECIFICATIONS
Offeror shall provide information for the following items.
MRI Scanner - Aera (1.5T) Requirement Yes/No/Included/Not Included/Additional Cost
Bore Size Tim 4G
Wireless patient physiological synchronization
Pressure Injector (Medrad Dual-Head MRI Injector)
Detachable Table Planning Suite:
Neuro Suite Angio Suite
Cardiac Suite Body Suite Onco Suite
Breast Suite Ortho Suite
Applications Software 1D/2d Pace
BLADE
iPAT2
PHOENIX
WARP
MDDW
CSS
DESST
GSE
SWI #Tim Siemens unique TimCT FastView
Localizer and CAIPIRINHA Coils
Head/Neck 16 DirectConnect Spine 24 Direct Connect
Body Coil (sm/lg) Shoulder 16 Coil including Large and
Small Knee 16 coil
CP Extremity Coil (Ankle/Foot) RS Hand/Wrist
Single Wide MRI Trailer Requirements (ADA compliant dressing Room with lockable storage area for the patient’s personal property)
Requirement Yes/No/Included/Not Included/Additional Cost Dressing Room (hardened Walls)
Dressing Room (Curtains) Lockable Storage
Staffing
Requirement Yes/No/Included/Not Included/Additional Cost MR Tech (x1)
Staffing Credentials Assistant (x2)
File details come from the government source that posted it. Updated .