fire door book 2022 .xlsx
XLSX spreadsheet 83 KB Posted
- Attached to
- H399--Annual Fire Door Inspection
- Solicitation number
- 36C26323Q0278
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Q and A.docx | DOCX document | |
| Life Safety Drawings 2022.pdf | ||
| 36C26323Q0278 0001_1.docx | DOCX document | |
| 36C26323Q0278 0001.pdf | ||
| DRAWING.pdf | ||
| WD15-5771 GRAND ISLAND.pdf | ||
| S02.36C26323Q0278.pdf | ||
| WD15-5005 OMAHA.pdf | ||
| 36C26323Q0278_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Basement
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 21 | |||
| Basement | ||||||||||||||||||||||||
| Room number | B728 | B723 | B721 | B836 | B815 | 700b | B622 | B989 | B579 | B577 | elect shop | B530 | B502 | B501 | B17 | B064 | B020 | B094 | B051 | B024 | B080 | |||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | |||
| 1 | Labels are clearly visible and legible on doors and frames. | |||||||||||||||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | |||||||||||||||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | |||||||||||||||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | |||||||||||||||||||||||
| 5 | No parts are missing or broken. | |||||||||||||||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
&16 Basement
1st Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 11 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 37 | ||||||
| 1st Floor | |||||||||||||||||||||||||||||||||
| Room number | 1269 | C205A | 1366 | 1406 | 1220 | C220 | C210 | 1206A | 1202 | B17 | 1105 | 1164 | C260b | C265A | 1051 | 1025 | 1025a | 1026 | 1012 | C235A | C104 | Room number | 1416 | 1415 | 1701 | 1777 | 1650 | c2358 | |||||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | |||||
| 1 | Labels are clearly visible and legible on doors and frames. | 1 | Labels are clearly visible and legible on doors and frames. | ||||||||||||||||||||||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | 2 | No open holes or breaks exist in surfaces of either the door or frame. | ||||||||||||||||||||||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | ||||||||||||||||||||||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | ||||||||||||||||||||||||||||||
| 5 | No parts are missing or broken. | 5 | No parts are missing or broken. | ||||||||||||||||||||||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 | 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm). Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors. Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | ||
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. | 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. | 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. | 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. | 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. | 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. | 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: | 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | Paragraph 4.1.4 | ||
| - Signs are informational | - Signs are informational | ||
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | ||
| - Signs shall be attached to the fire door by use of an adhesive | - Signs shall be attached to the fire door by use of an adhesive | ||
| - Mechanical attachment such as screws or nails shall not be permitted. | - Mechanical attachment such as screws or nails shall not be permitted. | ||
| - Signs shall not be installed on glazing material of fire doors | - Signs shall not be installed on glazing material of fire doors | ||
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door | - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
2nd Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 21 | |||
| 2nd Floor | ||||||||||||||||||||||||
| Room number | 2417 | 2446 | 2447 | 2543b | 2543 | 2542 | 2534 | 2349 | 2270 | 2340 | 2312 | 2283 | 2284 | 2111 | 2051 | 2041 | 2049 | 2018 | 2805 | C224 | 2000 | |||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | |||
| 1 | Labels are clearly visible and legible on doors and frames. | |||||||||||||||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | |||||||||||||||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | |||||||||||||||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | |||||||||||||||||||||||
| 5 | No parts are missing or broken. | |||||||||||||||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
3rd Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 8 | |||
| 3rd Floor | |||||||||||
| Room number | 3351 | 3324 | 3000 | 3267d | 3031 | 3062b | 3770a | 3754a | |||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | |||
| 1 | Labels are clearly visible and legible on doors and frames. | ||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | ||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | ||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | ||||||||||
| 5 | No parts are missing or broken. | ||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
4th floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 30 | ||||
| 4th Floor | ||||||||||||||||||||||||||||||||||
| Room number | 4329 | 4324 | 4331 | 4374 | 4374b | 4340 | 4339 | 4267 | door by 4267 | 4281 | 4215 | 4374G | 4370 | 4361 | 4209 | 4001 | 4374F | door by 4374F | 4819 | 4003 | 4816 | 4015 | 4028 | 4805 | 4783 | 4775 | 4042 | 4044 | 4061 | 4007 | ||||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | ||||
| 1 | Labels are clearly visible and legible on doors and frames. | Labels are clearly visible and legible on doors and frames. | ||||||||||||||||||||||||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | No open holes or breaks exist in surfaces of either the door or frame. | ||||||||||||||||||||||||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | ||||||||||||||||||||||||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | ||||||||||||||||||||||||||||||||
| 5 | No parts are missing or broken. | No parts are missing or broken. | ||||||||||||||||||||||||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm). Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors. Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | Paragraph 4.1.4 | |
| - Signs are informational | - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door | - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
5th floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 18 | |||
| 5th Floor | |||||||||||||||||||||
| Room number | 5705C | 5711 | 5607 | 5500 | 5511 | 5501 | 5502 | 5429 | 5419 | 5420 | 5001 | 5002 | 5003 | 5018 | 5203 | 5109 | 5037 | 5603 | |||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | |||
| 1 | Labels are clearly visible and legible on doors and frames. | ||||||||||||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | ||||||||||||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | ||||||||||||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | ||||||||||||||||||||
| 5 | No parts are missing or broken. | ||||||||||||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
6th Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 18 | |||
| 6th Floor | |||||||||||||||||||||
| Room number | 6705C | 6712 | 6600 | 6502 | 6508 | 6419 | doors by 6519 | 6001 | doors by 6002 | 6109 | 6018 | 6203 | 6307 | ||||||||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | |||
| 1 | Labels are clearly visible and legible on doors and frames. | ||||||||||||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | ||||||||||||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | ||||||||||||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | ||||||||||||||||||||
| 5 | No parts are missing or broken. | ||||||||||||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
7th Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 15 | |||||
| 7th Floor | ||||||||||||||||||||
| Room number | 7705c | 7614 | 7603 | 7509 | 7508 | 7511 | 7417 | 7414 | 7001 | 7002 | 7003a | 7018 | 7109 | 7203 | 7307 | |||||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | ||
| 1 | Labels are clearly visible and legible on doors and frames. | |||||||||||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | |||||||||||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | |||||||||||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | |||||||||||||||||||
| 5 | No parts are missing or broken. | |||||||||||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
8th Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 9 | |||
| 8th Floor | ||||||||||||
| Room number | 8705c | 8711 | 8511 | door by 8405 | 8001 | 8414 | 8111 | 8511 | 8311 | |||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | |||
| 1 | Labels are clearly visible and legible on doors and frames. | |||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | |||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | |||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | |||||||||||
| 5 | No parts are missing or broken. | |||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
9th Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 8 | |||
| 9th Floor | |||||||||||
| Room number | 9750d | 9702 | 9001 | 9401 | 9414 | 9111 | 9311 | 9511 | |||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | |||
| 1 | Labels are clearly visible and legible on doors and frames. | ||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | ||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | ||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | ||||||||||
| 5 | No parts are missing or broken. | ||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
10th Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 10 | |||
| 10th Floor | |||||||||||||
| Room number | 10707 | 10705 | 10700A | door by 10609 | 10501 | 10513 | door by 10418 | 10001 | 10414 | 10110 | |||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | |||
| 1 | Labels are clearly visible and legible on doors and frames. | ||||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | ||||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | ||||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | ||||||||||||
| 5 | No parts are missing or broken. | ||||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
11th Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 6 | ||||
| 11th Floor | ||||||||||
| Room number | 11705C | 11711 | 11001 | 11003A | 11110 | 11414A | ||||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | ||||
| 1 | Labels are clearly visible and legible on doors and frames. | |||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | |||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | |||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | |||||||||
| 5 | No parts are missing or broken. | |||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
12th Floor
| 1 | 1 | 1 | 1 | 1 | 1 | 6 | ||||
| 12th Floor | ||||||||||
| Room number | 12705 | 12705a | 12004 | 12003B | 12002 | 12017 | ||||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | ||||
| 1 | Labels are clearly visible and legible on doors and frames. | |||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | |||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | |||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | |||||||||
| 5 | No parts are missing or broken. | |||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |
13th and 14th floor
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 10 | |||
| 13th and 14th Floor | |||||||||||||
| Room number | 13705 | 13705a | 13000 | 13000a | 13000B | 14000a | 14001 | 14000a | |||||
| Item | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | Yes, No or N/A | ||||
| 1 | Labels are clearly visible and legible on doors and frames. | ||||||||||||
| 2 | No open holes or breaks exist in surfaces of either the door or frame. | ||||||||||||
| 3 | Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. | ||||||||||||
| 4 | The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. | ||||||||||||
| 5 | No parts are missing or broken. | ||||||||||||
| 6 | Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7 |
Paragraph 4.8.4: The clearance under the bottom of a door shall be a maximum of 3/4 in. (19 mm).
Paragraph 6.3.1.7: The clearances between the top and vertical edges of the door and the frame, and the meeting edges of doors swinging in pairs, shall be 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm) for steel doors and shall not exceed 1/8 in. (3.18 mm) for wood doors.
| 6.3.1.7.2 Clearances shall be measured from the pull face of the door(s). | |
| 7 | The self-closing devices is operational; that is, the active door completely closes when operated from the full open position. |
| 8 | If a coordinator is installed, the inactive leaf closes before the active leaf. |
| 9 | Latching hardware operates and secures the door when is is in the closed position. |
| 10 | Auxiliary hardware items that interfere or prohibit operation not installed on the door or frame. |
| 11 | No field modifications to the door assembly have been performed that void the label. |
| 12 | Meeting edge protection, gasketing and edge seal, where required, are inspected to verify their presence and integrity. |
| 13 | Signage affixed to a door meet the requirements listed below: |
| Paragraph 4.1.4 | |
| - Signs are informational | |
| - All attached signs shall not exceed 5 percent of the area of the face of the fire door. | |
| - Signs shall be attached to the fire door by use of an adhesive | |
| - Mechanical attachment such as screws or nails shall not be permitted. | |
| - Signs shall not be installed on glazing material of fire doors | |
| - Signs shall not be installed on the surface of fire doors so as to impair or otherwise interfere with the proper operation of fire door |