Attachment A InnoWave Pro Equipment Specs.pdf
PDF 3 MB Posted
- Attached to
- Z2DA--Install Infrastructure to Support SPS Federal contract opportunity
- Solicitation number
- 36C25923Q0020
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| S04 - Site Visit Meeting Doc.pdf | ||
| Attachment B Photos new VA owned equipment.pdf | ||
| S05 - Amendment Sections.pdf | ||
| 36C25923Q0020 0001.docx | DOCX document | |
| Attachment C Specifications Addendum RFI 1 554-23-112 Install Infrastructure SPS.pdf | ||
| S04 - 554-23-112 Site Walk Attendance.pdf | ||
| S02 - Specifications proj 554-23-112 Install Infrastructure SPS.pdf | ||
| S02 - Drawings proj 554-23-112 Install Infrastructure SPS.pdf | ||
| 36C25923Q0020_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T I T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 101
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Physical dimensions and weight
External height (lid closed)
43.6 in. 1109 mm
External height (lid open)
65.3 in. 1659 mm
External width 49.6 in. 1260 mm
External depth
36.1 in. 918 mm
Net weight (dry)
905 lbs
410 kg
Operating weight (tank filled)
380 lbs
172 kg
Max. operating weight (incl. filled tank, chemicals, and instruments to be cleaned)
1162 lbs
527 kg
External Dimension i n m m i n m m
49.63 in. [1260 mm] i n m i n m
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 101A
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Suggested Clearances When Servicing Machine
18.0
18.0
18.0
18.0
Notes:
1. Clearances are in INCHES
2. Machine should be moved to a position with minimum clearances shown for servicing.
3. Space for service clearances are not required while the unit is in the installed position.
4. Adequate space should be provided in the room for servicing the machine, so it can be wheeled or moved to accommodate servicing.
5. Reference other pages for installation clearances.
90.0
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 102
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Utility Connections
REAR VIEW WITH LID CLOSED, SHOWING SERVICES
1113mm [4 4]
268mm [11]
Reverse Osmosis WATER 3/4" BSPP
HOT WATER 3/4" BSPP
COLD WATER 3/4" BSPP
OVERFLOW
NB. DO NOT
RESTRICT
OR BLOCK
165,1mm [6]
230,1mm [9]
295,1mm [12]
345,1mm [14]
395,1mm [16]
211,6mm [ 8] i n
MAINS POWER ENTRY
REMOVABLE REAR
ACCESS PANELS
TEMPERING VALVE
MAINTAIN AIR GAP
DO NOT BLOCK
MACHINE BASE REAR
AIR SUPPLY 0.32 in [8 mm] O.D. TUBE
PRINTER RS232
D-SUB FEMALE
EXPANSION PORT
COLD WATER DRAIN COOLING
FLEXIBLE RUBBER HOSE 3/4" FEMALE
6.75 in. [170 mm]
DO NOT BLOCK
MACHINE BASE REAR
COLD WATER DRAIN COOLING
FLEXIBLE RUBBER HOSE 3/4" FEMALE
3.50 in. [90 mm]
DRAIN OUTSIDE OF MACHINE'S FOOTPRINT
REAR VIEW WITH LID CLOSED
4.00 in. [104.6 mm]
10.50 in. [268 mm]
15.5 in. [395 mm]
13.63 in. [345 mm]
11.63 in. [295 mm]
9.00 in. [230 mm]
6.50 in. [165 mm] i n m m i n m m bottom of drain pipe to floor
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 103
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Installed Operation Clearances
DRAIN WITHIN OR OUTSIDE MACHINE'S FOOTPINT
FRONT VIEW WITH LID OPEN
m m i n
5.88 in. [150 mm] 5.88 in. [150 mm] i n i n m m i n m m
49.63 in. [1260 mm]
CARRIER TOP
EMERGENCY STOP
CHEMICAL STORAGE
2 X 10 LITRES.
(DOORS OPEN)
DO NOT BLOCK GAP
BETWEEN SIDE & FRONT
KICKPLATES AND FLOOR
CONTROL PANEL
(COVER REMOVED
FOR CLARITY)
FOOT SWITCH
CONTROL
ELECTRICAL PANEL
(COVER REMOVED
FOR CLARITY)
4.3" TFT TOUCH
DISPLAY
TEMPERING VALVE MAINTAIN AIR GAP
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 104
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Installed Operation Clearances
DRAIN WITHIN MACHINE'S FOOTPRINT
TOP VIEW
DRAIN
FLOOR SINK
150mm [6]150mm [6]
200mm [8]
STAINLESS STEEL TUBE
1 METER LONG STAINLESS STEEL PIPE SUPPLIED
CAN BE CUT DOWN TO SUIT
POSITION ANY DIRECTION
AT REAR FROM DRAIN OUTLET
PIPE MUST SLOPE TOWARD DRAIN.
CAN PASS THROUGH WALLS
AS REQUIRED.
49.63 in. [1260 mm]
6 in. [152 mm] i n
267,8mm [11] i n i n m m
DOOR SWING
Installed Operation Clearances
DRAIN OUTSIDE OF MACHINE'S FOOTPRINT
TOP VIEW
5.88 in. [150 mm] 5.88 in. [150 mm] i n m m
10.5 in. [268 mm]
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 105
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Installed Operation Clearances
DRAIN WITHIN MACHINE'S FOOTPRINT
SIDE VIEW
Installed Operation Clearances
DRAIN OUTSIDE OF MACHINE'S FOOTPRINT
SIDE VIEW
(1113mm [
44] OVERA
LL CLOSE
D)
101mm [4]
CLOSED
868,6mm [34]
503,5mm [20]
Ø53,9mm [2] I/D
200mm [8] i n
6 in. [152 mm]
SILICONE ELBOW TUBING
TO CONNECT TO DRAIN
STAINLESS STEEL TUBE
1 METER LONG STAINLESS STEEL PIPE SUPPLIED
CAN BE CUT DOWN TO SUIT
POSITION ANY DIRECTION
AT REAR FROM DRAIN OUTLET
PIPE MUST SLOPE TOWARD DRAIN.
CAN PASS THROUGH WALLS
AS REQUIRED.
0.63 in. [14 mm]
34.25 in. [869 mm]
7.88 in. [200 mm] i n m m
C
L O
S E
D i n m m
O
V E
R A
L L
C
L O
S E
D
19.88 in. [503 mm]
Ø 2.13 in. [54 mm] ID
TEMPERING VALVE MAINTAIN AIR GAP
AutoCAD SHX Text E
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 106
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Installed Operation Clearances
DRAIN WITHIN MACHINE'S FOOTPRINT
SIDE VIEW
Installed Operation Clearances
DRAIN OUTSIDE OF MACHINE'S FOOTPRINT
SIDE VIEW
503,5mm [20]
Ø53,9mm [2] I/D
200mm [8] i n
6 in. [152 mm]
(1663mm [
65] OVERA
LL OPEN)
651mm [26
] OPEN
11.5 in. [293 mm]
REACH
SILICONE ELBOW TUBING
TO CONNECT TO DRAIN
STAINLESS STEEL TUBE
1 METER LONG STAINLESS STEEL PIPE SUPPLIED
CAN BE CUT DOWN TO SUIT POSITION ANY DIRECTION
AT REAR FROM DRAIN OUTLET PIPE MUST SLOPE TOWARD DRAIN.
CAN PASS THROUGH WALLS AS REQUIRED.
7.88 in. [200 mm]
19.88 in. [503 mm]
Ø 2.13 in. [54 mm] I/D i n m m
O
V E
R A
L L
O
P E
N i n m m
O
P E
N
TEMPERING VALVE MAINTAIN AIR GAP
AutoCAD SHX Text E
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 107
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Water supply requirements:
Water hardness (CaCO3), quality and purity, hot and cold supplies
< 125 ppm with water quality and purity tested and approved for disinfection as per ANSI/AAMI ST 15883-1:2009 (item 6.4.1 and
6.4.2) or AAMI TIR 34
Pressure (hot and cold), Static 30 to 70 psi (2.0 to 5.0 Bar)
Flow rate (hot and cold) 3 to 8 gal/min. (11 to 30 litres/min.)
Temperature (hot and cold) Cold: +41 to 86 ºF (+5 to 30 ºC) Hot: +122 to 176 ºF (+50 to 80 ºC)*
Connections
3/4 in. BSP male thread Rubber gasket is required. Do not use tape or any sealant, 3/4" NPT facility connections required. Hose connections will not work. Do not hard pipe water connections.
Machine must be easily movable for service and maintenance.
*The unit is able to operate without hot water connection or with hot water supply cooler than recommended minimum temperature of +122 ºF (+50 ºC). Using only cold water or low-temperature hot water will result in longer cycle operation as water takes longer to heat up in unit.
Typical water consumption per wash
Water consumption will vary depending on volume of instruments loaded and temperature of inlet water supply. The water consumption below describes complete wash cycle at +104 ºF (+40 ºC), with no instruments loaded.
Maximum water consumption for complete wash cycle
Stage
Cold water Hot water RO Water *
Total for stage
Pre-wash
10.6 gallons
(40 litres) nil nil
10.6 gallons
(40 litres)
Wash
1 gallon
(3.7 litres)
65 gallons
(246 litres) nil
66 gallons
(250 litres)
Rinse
10.6 gallons
(40 litres) nil nil
10.6 gallons
(40 litres)
Disinfection
10.6 gallons
(40 litres) nil
10.6 gallons
(40 liters)
21.2 gallons
(40 litres)
Disinfection Condensate
43.5 gallons
(165 liters) nil nil
43.5 gallons
(165 liters)
Cooling
28 gallons
(105 liters) nil nil
28 gallons
(105 liters)
Total water consumption
104.3 gallons
(393 litres)
65 gallons
247 (litres)
10.6 gallons
(40 liters)
180 gallons
(681 litres) includes 38 gallons R.O.
*If RO is used, cold water is not used during disinfection
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 108
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Site drain requirements The site drain should meet the following requirements:
Drain connection
2.125 in. (54 mm) outlet from unit.
Drain must be fitted with suitable traps.
Remote drain must slope to floor drain. Air gap must be maintained per local code.
Do not hard pipe drain connection. The machine must be easily movable for service and maintenance.
Position
Unit should be positioned so that the centerline of the unit is aligned with the center of the floor sink outlet.
If remote drain is used, drain line must be level or sloping away from unit.
Remote drain also requires a floor sink.
Adhere to local code.
Capacity
47.5 gallons/minute. (30 litres/minute) Maximum discharge to drain including overflow, (minimum drain capacity of 8 gallons/minute). When drain tempering valve is installed, maximum flow to drain is 8 gallons/minute including DTV cooling water flow rate.
Overflow Drain
Internally connected within the machine to the drain pipe, downstream of the drain valve. Maximum overflow drain is 8 gallons per minute.
Effluent temperature up to +140 ºF (+60 ºC) Max. and +203 ºF (+95 ºC) without DTV kit. DTV is required in North America. Other locations refer to local or national codes.
Floor Sink
Dimensions
6.0 in x 6.0 (152 mm x 152mm) in with a 3.0 in. (76 mm) minimum drain outlet at bottom of floor sink.
Compressed Air
Supply
Pressure: 5.5 bar to 7.0 bar (80 to 100 psi).
Quality: If medical grade compressed air is not used, and Eliminizer filter needs to be included at time of order.
Connection: 8mm (0.315 in) dia. Quick fit hose connector.
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 109A
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Electrical power supply requirements:
Requirement
Model
IWPRO60
Electrical supply voltage
200-230 V AC 3P+PE
(Three-phase and protective earth)
Frequency: 60 Hz
Supply current
Site Current Capacity Current Capacity: >48 A per phase
Dedicated circuit is required with a minimum circuit breaker rating of 63A or greater. Refer to local codes
Electrical power requirement
18 kW
Allowable supply voltage fluctuation ±10% of nominal voltage
Over-voltage category II Transient over-voltages typically present on mains supply
Electrical connections
Model Conductor
Color and Marking
IWPRO60 (208 V AC 3P+PE)
supplied with 6 ft (1.8 m) 4-core power cable.
Protective earth Green/Yellow
Live 1 Black 1
Live 2 Black 2
Live 3 Black 3
The disconnect switch must:
-- Isolate all poles simultaneously
-- Be lockable in the off position
-- Comply with standards IEC/EN 61058-1 and IEC 60447 (creepage and clearances for 4kV transient voltage)
-- Be situated close to the equipment for ease of accessibility, and in a position where the operator can turn it off in an emergency without leaning over the machine.
-- Marked as the disconnection device for this equipment
-- Disconnect device off-position should be clearly marked (O) and the on-position should be marked (l)
-- Hard wiring power cable to disconnect switch is recommended. Use of an electrical plug is not recommended.
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 109B
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Electrical power supply requirements:
Requirement
Model
IW532055NPR
Electrical supply voltage
380V-415V 3P+N+PE
(Three-phase, neutral and protective earth)
Frequency: 50 Hz
Supply current
Site Current Capacity: >33 A per phase
Dedicated circuit is required with a circuit breaker rating of 40A or greater. Refer to local codes.
Electrical power requirement
22 kW
Allowable supply voltage fluctuation ±10% of nominal voltage
Over-voltage category II Transient over-voltages typically present on mains supply
Electrical connections
Model Conductor
Color and Marking
IW532055NPR(380-415VAC 3P+N+PE)
supplied with 9.84 ft (3 m) 5-core power cable
Protective earth Green/Yellow
Live 1 Brown
Live 2 Black
Live 3
Grey
Neutral Blue
Typical power consumption per wash
Power consumption will vary depending on cycle settings and temperature of inlet water supply. The power consumption below describes complete wash cycle at +104 ºF (+40 ºC).
Maximum power consumption for complete wash cycle
Phase
Power consumption kWh
Pre-wash 11.9
Wash 2.6
Rinse 1 0.6
Rinse 2 0.6
Disinfection 3.6
Total power consumption
9.3
T L E
Corporation SIZE: SCALE: DRAWN BY: DRAWING NUMBER: PART NUMBER: REVISION:
This document contains confidential and proprietary information of STERIS Corporation. Neither this document nor the information herein are to be reproduced, either in part or in whole, except as specifically authorized by STERIS Corporation.
SHEET
A
OF 10 10
NTS TJ B1101826211393356
Equipment Specifications built after SN: 11189855522 InnoWave Pro
Operating / Working environment location requirements
General and environmental requirements
Proposed operating location for unit much meet or exceed following requirements
Description Requirements
Operating surface
On level floor, capable of supporting a weight of at least 1200 lb
(545 kg).
Location requirement Altitude Indoors only, altitude up to 6562 ft (2000 m)
Ambient operating temperature range
+41 ºF to 104 ºF (+5 ºC to 40 ºC)
Maximum humidity
80% relative humidity for up to +88 ºF (+31 ºC) decreasing linearly to 50% relative humidity at +104 ºF (+40 ºC)
Site services
Within 6 ft (1.8 m) of electrical isolator.
Within 6 ft (1.8 m) of hot and cold water connections.
Within 3 ft (1.0 m) of external site drain for effluent.
Ambient lighting 500 lux (46.5 foot-candle) minimum room lighting
Noise generated during operation 69 dBA at distance of 6 ft (1.8 m) from front of unit
Heat output during operation 7200 BTU/hr during cycle
Shipping crate dimensions and weight
Shipping crate height
59.1 in. 1501 mm
Shipping crate width
59.5 in. 1511 mm
Shipping crate depth
45.3 in. 1151 mm
Shipping crate gross weight
1135 lb
515 kg
Shipping information
Transportation and storage:
Make sure package marking instructions and environmental conditions are always followed during transport and storage of InnoWave™ Pro.
Lifting:
Lifting and maneuvering the InnoWave™ Pro in shipping crate must be done with pallet truck or forklift truck able to carry load in excess of 1135 lb (515 kg).
Storage markings:
The markings on shipping crate stipulate unit's storage conditions and handling information.
Keep dry This way up
File details come from the government source that posted it. Updated .