This document is an electrical site plan and specifications for renovations to Building 409 at Fort Riley, Kansas. The project involves relocating an existing backup generator to a new location near Building 409 and providing all associated electrical infrastructure. Work includes installing new secondary feeders from the transformer to a new automatic transfer switch and main switchboard housed in a pad-mounted NEMA 4 enclosure. A new generator feeder, Panel G feeder, Panel AB feeder, chiller feeder, and associated signal and control conduits will be routed from the switchboard. Additional scope involves providing site lighting branch circuits, monitoring circuits for post indicator valves, and disconnecting and removing existing secondary equipment from the transformer. The solicitation number is 36C25920Q0188 for the opportunity to relocate the backup generator at Fort Riley, issued by the Department of Veterans Affairs Veterans Health Administration VISN 19.

36C25920Q0188 0001 Electrical Site Plan.pdf

View the file

Other files

File Type Posted
36C25920Q0188-0001004.docx DOCX document
36C25920Q0188-0001006.pdf PDF
36C25920Q0188-0001007.pdf PDF
36C25920Q0188-000.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

BUILDING 409

BUILDING 410

ASPHALT PARKING LOT

ASPHALT PARKING LOT

ASPHALT PARKING LOT

ASPHALT PARKING LOT

(A S

P H

A L T

P E

R S

H

IN

G A

V E

N U

E

CB

D

S

D

PERSHING COURT (ASPHALT)

CB

T

E

DS

DS

CO

DS DS

DS

DS

DS

(A S

P H

A L T

P E

R S

H

IN

G A

V E

N U

E

CB

DS

DS

DS

DS

CO

DS

T

G

DS

G

C

C

E

DSDS DS

E

E

C

COMM PED NOT MARKED

DSDS

C

DS

P

TYP.

P

P2

P2

MH-24C

MANHOLE

TELECOMMUNICATIONS

%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%

%PRODUCTION DATA 1%

A N

S I

D

ES101

P -4

B

L D

G

V

A C

A L L C

E N

T E

R

B U

IL

D

IN

G

R

E N

O V

A T

IO

N

F O

R T R

IL

E Y

K A

N S

A S

K A

N S

A S C

IT

Y

M O

E T

H S

T R

E E

T

K A

N S

A S C

IT

Y D

IS

T R

IC

T

V E

S .d g n

GENERAL SHEET NOTES

A1 SCALE: 1" = 20' 20' 40'0

N

SHEET KEYNOTES

W

IN

K E

L

F

IL

E N

A M

E

S

E C

O V

E R S

H E

E T

S E

E C

O V

E R S

H E

E T

D R

A W

IN

G C

O D

E

M L

IT

T L

J L

O C

K W

O O

L E

C T

R

IC

A L S

IT

E P

L A

N

SEE SHEET ES701 FOR THE LIGHT FIXTURE SCHEDULE.4.

SEE SHEET E-601 FOR ELECTRICAL ONE-LINE DIAGRAM.3.

SEE SHEET E-001 FOR ELECTRICAL LEGEND AND GENERAL NOTES.2.

SEE SHEET CD100 FOR DEMOLITION AFFECTING THIS WORK.1.

ELECTRICAL SITE PLAN

EXISTING MEDIUM VOLTAGE SECTIONALIZER SWITCH.

EXISTING MEDIUM VOLTAGE FEEDER TO TRANSFORMER LOCATION.

S

R O

E T

H L

IS

B E

R G

E R

MOVING INTO BUILDING 409.

RELOCATED TO THIS LOCATION WHEN THE USER IS IN TRANSITION OF

SEPARATE CONTRACT. EXISTING GENERATOR TO BUILDING 610 IS BEING

PROPOSED LOCATION OF EXISTING GENERATOR BEING INSTALLED UNDER 15.

OFFICER REPRESENTATIVE.

GENERATOR PROVISIONS WITH THE USER, THROUGH THE CONTRACTING

ADDITIONAL INFORMATION. COORDINATE EXACT LOCATION AND EXISTING

CONTROLS INTERFACE. SEE SHEET E-601 AND DETAIL A8/ES501 FOR

STRUCTURAL STEEL SUPPORT, FOR EXISTING GENERATOR LOADS AND NEW

PROVIDE DISCONNECT FOR PANEL G AND CONTROLS ENCLOSURE, ON 14.

REPRESENTATIVE.

PROVISIONS WITH THE USER, THROUGH THE CONTRACTING OFFICER

INFORMATION. COORDINATE EXACT LOCATION AND EXISTING GENERATOR

LOCATION. SEE SHEET E-601 AND DETAIL E8/ES501 FOR ADDITIONAL

PROVIDE GENERATOR FEEDER TERMINAL CABINET NEAR NEW GENERATOR 13.

ADDITIONAL INFORMATION.

TRANSFER SWITCH (ATS). SEE SHEET E-601 AND DETAIL D7/ES502 FOR

CONDUIT FROM THE GENERATOR TERMINAL CABINET TO THE AUTOMATIC

PROVIDE NEW SECONDARY FEEDER, PANEL G FEEDER, AND CONTROLS 12.

DIAGRAM A8/ES701 FOR ADDITIONAL INFORMATION.

CIRCUIT THROUGH EXTERIOR LIGHTING CONTACTOR CONTROLS. SEE

PROVIDE BRANCH FEEDER TO NEW POLE MOUNTED LIGHTING. ROUTE 11.

FOR ADDITIONAL INFORMATION.

MECH 001. SEE DETAIL D1/ES502 AND SHEETS EL100, EP100, AND E-601 AND

PROVIDE NEW PANEL AB FEEDER AND SITE LIGHTING BRANCH CIRCUIT FROM 10.

INFORMATION.

SWITCHBOARD. SEE SHEET E-601 AND DETAIL A4/ES502 FOR ADDITIONAL

TERMINAL CABINET TO THE AUTOMATIC TRANSFER SWITCH (ATS) AND MAIN

CHILLER FEEDER, AND CONTROLS CONDUIT FROM THE GENERATOR

PROVIDE NEW GENERATOR FEEDER, PANEL G FEEDER, PANEL AB FEEDER, 9.

EP100 AND E-601 FOR ADDITIONAL INFORMATION.

SWITCHBOARD TO THE ENCLOSURE AT ELECTRICAL ROOM 012. SEE SHEETS

PROVIDE FEEDER AND SIGNAL CONDUITS WITH CABLES FROM THE MAIN 8.

ADDITIONAL INFORMATION.

E1/ES501 FOR SIMILAR PAD REQUIREMENTS. SEE SHEET E-601 FOR

SWITCHBOARD AS PAD MOUNTED IN NEMA 4 ENCLOSURES. SEE DETAIL

PROVIDE EXTERIOR AUTOMATIC TRANSFER SWITCH AND MAIN 7.

A1/ES502 FOR ADDITIONAL INFORMATION.

AUTOMATIC TRANSFER SWITCH (ATS). SEE SHEETS EP100, E-601, AND DETAIL

PROVIDE NEW SECONDARY FEEDER FROM THE TRANSFORMER TO THE 6.

ADDITIONAL INFORMATION.

LOCATION. SEE SHEETS ED601, E-601, AND DETAIL E1/ ES501 FOR

TRANSFORMER AND ASSOCIATED APPURTENANCES AT THE EXISTING

EXISTING MEDIUM VOLTAGE FEEDER. PROVIDE NEW BUILDING

REUSE. MODIFY OR PROVIDE NEW PAD AND APPURENTANCES AROUND

PLACE AS DIRECTED. RETAIN THE MEDIUM VOLTAGE CONDUCTORS FOR

TRANSFORMER TO THE ELECTRIC SHOP STORAGE YARD (BUILDING 337) AND

DISCONNECT AND REMOVE EXISTING TRANSFORMER. TRANSPORT EXISTING 5.

FA001 AND FA100 FOR ADDITIONAL INFORMATION.

INSTALLING CONDUIT. SEE SECTION D1/ES701 FOR SIMILAR. SEE SHEETS

DEVICE AT FACP. COORDINATE LOCATION WITH VALVE INSTALLER PRIOR TO

PROVIDE MONITORING CIRCUIT IN 1" CONDUIT FROM SURGE SUPPRESSION

PROVIDE POST INDICATOR VALVE (PIV) MONITORING MODULE AT PIV. 4.

INFORMATION.

BUILDING EQUIPMENT. SEE SHEETS ED100 AND ED601 FOR ADDITIONAL

DISCONNECT AND REMOVE EXISTING SECONDARY FROM TRANSFORMER TO 3.

REUSE CONDUIT PENETRATION FOR FIRE ALARM PIV CONDUIT AND CABLING

TERMINALS TO HANDHOLE. CAP CABLE ENDS.

DISCONNECT AND REMOVE THE COPPER CABLING FROM BUILDING 2.

ADDITIONAL INFORMATION.

CONTINUED TO THE TER. SEE SHEETS, EP100, T-001, T-100 AND T-600 FOR

EXISTING OUTSIDE PLANT CONDUIT FROM MANHOLE TO BUILDING, AND 1.

CONFORMED

J U

L Y

A4

ES502

A7

ES502

D7

ES502

D1

ES701

D1

ES502

A1

ES502

D4

ES502

File details come from the government source that posted it. Updated .