36C25918R0600-0004002.docx
DOCX document 15 KB Posted
- Attached to
- Construction of a temporary covered walkway (VA-18-00109708) Federal contract opportunity
- Solicitation number
- 36C25918R0600
About this file
36C25918R0600 0004 MRI Temporary Covered Walkway - Addendum 3.docx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25918C0339-000.docx | DOCX document | |
| 36C25918R0600-0006000.docx | DOCX document | |
| 36C25918R0600-0005000.docx | DOCX document | |
| 36C25918R0600-0004000.docx | DOCX document | |
| 36C25918R0600-0004001.pdf | ||
| 36C25918R0600-0003000.docx | DOCX document | |
| 36C25918R0600-0002002.pdf | ||
| 36C25918R0600-0002001.pdf | ||
| 36C25918R0600-0002000.docx | DOCX document | |
| 36C25918R0600-0001000.docx | DOCX document | |
| 36C25918R0600-0001005.pdf | ||
| 36C25918R0600-0001004.pdf | ||
| 36C25918R0600-0001003.pdf | ||
| 36C25918R0600-0001006.pdf | ||
| 36C25918R0600-0001007.pdf | ||
| 36C25918R0600-0001002.pdf | ||
| 36C25918R0600-0001001.pdf | ||
| 36C25918R0600-003.pdf | ||
| 36C25918R0600-006.pdf | ||
| 36C25918R0600-001.docx | DOCX document | |
| 36C25918R0600-007.docx | DOCX document | |
| 36C25918R0600-005.pdf | ||
| 36C25918R0600-004.pdf | ||
| 36C25918R0600-002.pdf | ||
| 36C25918R0600-000.docx | DOCX document |
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM
| Project: MRI Temporary Covered Walkway | Date: 08/27/2018 | |
| Project Number: 442-18-014S | Addendum Number: 3 |
The following changes, additional and/or deletions are hereby made a part of the Construction Documents for the above noted project, fully and completely as is the same were fully contained therein. All other terms, conditions, and specification of the original documents remain unchanged.
Clarification items and other changes included in the Addendum 3 (see clouded areas on plans):
1. A100: Door Schedule updated for Double 36” doors.
2. A101: Site & Floor Plan: Single door on West of Covered Walkway revised to double 36” doors. A small area of sidewalk has been added to create a landing for the doorway. Gutter downspout has been relocated to the center of the structure.
3. A101: Wall Framing Plan: Header revised over larger double door.
4. A101: Roof Framing Plan: Built-up beam upsized to 3-2x12. Angle of roof valley adjusted to 45°. Gutter revised to slope to a downspout in the center, and drain into the grass detention pond area.
End of Addendum 3