Attachment 2-ADD 1 - DESIGN PRIMARY POWER.pdf

PDF 8 MB Posted

Attached to
Y1DA--756-16-110 NRM Upgrade Underground Feeder
Solicitation number
36C25722B0001
Issued by

About this file

This is a pre-solicitation notice for an upcoming invitation for bid to upgrade underground feeders at the VA El Paso Healthcare System located in El Paso, Texas. The project includes demolishing existing utility structures and furnishing labor and materials to replace utility transformers and switches. The government anticipates releasing a solicitation on October 1, 2021 with a bid due date of November 2, 2021. The contract will be firm-fixed-price. The project is set aside 100% for service-disabled veteran-owned small businesses. The estimated cost range is $1-2 million. Apparent successful offerors must be verified as an SDVOSB by the VA's Center for Verification and Evaluation prior to submission. The applicable NAICS code is 238210.

View the file

Other files

File Type Posted
36C25722B0001 0005.docx DOCX document
Attachment 1-ADD. #1 SPECIFICATIONS.pdf PDF
36C25722B0001 0004.docx DOCX document
Attachment 3-E6_07.pdf PDF
Consolidated RFI for Underground feeder Responses.pdf PDF
36C25722B0001 0003.docx DOCX document
36C25722B0001 0002.docx DOCX document
36C25722B0001 0001.docx DOCX document
Drawings .pdf PDF
36C25722B0001_3.docx DOCX document
Specifications.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT NUMBER:

ISSUE DATE:

EA #:

CLIENT #:

PROJECT DIRECTORY:

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

WWW.ENAPAYLLC.COM

1331 RIVER BEND DRIVE

DALLAS, TEXAS 75247

MR. FRED C. CRABTREE, JR., P.E.

T. 214.696.6291

1255 CORPORATE DRIVE - SUITE 200

IRVING, TEXAS 75038

MR. MICHAEL BURCH

T. 469.242.4707

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CAMPOS ENGINEERING

ENAPAY, LLC

HILL INTERNATIONAL

A-000

DESIGN PRIMARY POWER, SECONDARY SIDE

ISSUE FOR CONSTRUCTION

D E

S

IG

N P

R

IM

A R

Y P

O W

E R

, S E

C O

N D

A R

Y S

ID

E

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

E A

.0

756-16-110

EA03.0111

5001 N. PIEDRAS / EL PASO, TEXAS 79930

VA EL PASO

5001 N. PIEDRAS

EL PASO, TEXAS 79930

MR. KEVIN ANGELES

03-31-2021 2021-02-12

March 31, 2021

2021-03-31

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

EA:CLIENT:

1 2 3 4 5 6 7 8

S

D ZIP

FORCE PROTECTION STREET ADDRESS

FORCE PROTECTION CITY AND ZIP

FORCE PROTECTION NAME

FORCE PROTECTION PH AND FAX

MEP STREET ADDRESS

MEP CITY AND ZIP

MEP ENGINEERS

MEP PH AND FAX

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CONSULTANT 01 NAME

CONSULTANT 01 PH AND FAX

FORCE PROTECTION CONTACT

ENAPAY, LLC

MEP CONTACT

ENAPAY, LLC

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

REVISION SCHEDULE

No. DESCRIPTION DATE

1331 RIVER BEND DRIVE

DALLAS, TEXAS 75247

MR. FRED C. CRABTREE, JR., P.E.

T. 214.696.6291

1255 CORPORATE DRIVE - SUITE 200

IRVING, TEXAS 75038

MR. MICHAEL BURCH

T. 469.242.4707

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CAMPOS ENGINEERING

ENAPAY, LLC

HILL INTERNATIONAL

PROJECT NUMBER:

BUILDING NUMBER:

EA:CLIENT:

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

WWW.ENAPAYLLC.COM

SYMBOLS AND NOTES

DESIGN PRIMARY POWER

SECONDARY SIDE

5001 N. PIEDRAS / EL PASO, TEXAS 79930

VA EL PASO

5001 N. PIEDRAS

EL PASO, TEXAS 79930

MR. KEVIN ANGELES

756-16-110 EA03.0111

D

ES

IG

N

P R

IM

A

R Y

PO

W

ER

. S

EC

O

N D

A R

Y

SI

D E

IS

SU

E

FO

R C

O N

ST

R

U C

TI

O

N

PR

O

JE

C T

N U

M B

ER

: E

A

.0

E-0

A

H1A-1 CIRCUIT NUMBER

LIGHT FIXTURE TYPE

XX/XX/XX/XX

FUSE SIZE

POLE(S)

FRAME SIZE

NEMA RATING

a

SWITCHING

CONFIGURATION

E

VERTICALVERT

SWGR SWITCHGEAR

MEDIUM VOLTAGEMV

MOUNTEDMTD

MEZZ MEZZANINE

MECHANICALMECH

LOW POWER FACTORLPF

INSTRUMENT/INSTRUMENTATIONINST

HORIZONTALHORIZ

HPF HIGH POWER FACTOR

FUTUREFUT

EQUIPMENTEQPT

ES ENERGY SAVING

ELECTRIC/ELECTRICALELEC

ELECTRICAL WATER HEATEREWH

EXH EXHAUST

CND CONDUCTOR

CONTINUATIONCONT

CATALOG NUMBERCAT NO.

BOTTOM OF TRAYBOT

BOD BOTTOM OF DUCT

LIGHTING SYMBOL LEGEND

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

NIC

NFS

NO

POLE(S)

OVERHEADOH

NTS

P

PA

PL

PVC

PNL

RC

RCP

PF

SWITCH

REC

RVSS

RGS

SF

SPDT

SW

SS

SWBD

TA

TAS

SPST

SINGLE-POLE, DOUBLE-THROW

TRIP AMPERE(S)

SINGLE-POLE, SINGLE-THROW

SWITCHBOARD

START-STOP

RECEPTACLES(S)

SQUARE FOOT OR FEET

REDUCED VOLTAGE, SOLID STATE

RIGID GALVANIZED STEEL

REFLECTED CEILING PLAN

POLYVINYL CHLORIDE

REMOTE CONTROL

PUBLIC ADDRESS SYSTEM

POWER FACTOR

PANELBOARD

PILOT LIGHT

NOT TO SCALE

NORMALLY OPEN

NON-FUSIBLE SAFETY SWITCH

NOT IN CONTRACT

TEXAS ACCESSIBILITY STANDARDS

TYPICAL

TU

TEMP

TEL

TYP

TV

UL

UNO

UPS

V

VA

UG

WITH

WITHOUT

WATT(S)

DELTA

PHASE(S)

NUMBER

W

VFD

WP

W/ W/O

XP

XFMR

EXPLOSION-PROOF

TRANSFORMER

WEATHERPROOF

VOLTAGE OR VOLT(S)

VARIABLE FREQUENCY DRIVE

VOLT-AMPERE(S)

UNLESS NOTED OTHERWISE

UNINTERRUPTIBLE POWER SUPPLY

UNDERWRITERS LABORATORIES, INC.

TEXAS UTILITIES ELECTRIC

UNDERGROUND

TELEVISION

TEMPORARY

TELEPHONE

FS

FLEX

HERTZ

G

HVAC

HPS

HID

HP

HOA

GFI

FVR

FVNR

GS

HZ

KV

KWH

KW

KA

JBOX

IMC

IG

IES

KVA

AC

ACCU

A

AFC

AFF

ADA

AIC

AHU

ALT

ARCH

APPROX

AFG

ATS

AUX

AWG

BFG

BFC

C

CATV

CCTV

CB

CKT

BLDG

CLOSED-CIRCUIT TELEVISION

CIRCUIT BREAKER

CABLE TELEVISION

CONDUIT OR TUBING

BUILDING

BELOW FINISHED GRADE

AUTOMATIC TRANSFER SWITCH

APPROXIMATE OR APPROXIMATELY

AMPERE INTERRUPTING CAPACITY(ROOT

AMERICANS WITH DISABILITIES ACT

AIR-COOLED CONDENSING UNIT

BELOW FINISHED CEILING

AUXILIARY

AMERICAN WIRE GAGE

ARCHITECT

ALTERNATE

MEAN SQUARE ALTERNATE)

ABOVE FINISHED CEILING

AIR HANDLING UNIT

ABOVE FINISHED GRADE

ABOVE FINISHED FLOOR

ALTERNATING CURRENT

AMPERE(S)

CIRCUIT

m

MIC

MAX

MH

MCP

MCC

MCB

LTG

LPS

KVAR

MIN

NEMA

NEC

NC

MVAR

MW

MVA

MTS

MMS

mm

MLO

NFPA

PANELBOARD, SWITCHBOARD OR MOTOR CONTROL CENTER

CLG

CT(S)

DC

DISC

DIV

COMM

DPDT

DPST

EGS

EC

EHH

DWG(S)

ELEV

EMH

EWC

EX

EMT

EMERG

F

FACP

FAAP

FBO

FLA

FL

CONDUIT ABOVE CEILING

BRANCH CIRCUIT HOMERUN TO PANELBOARD. EGC TO BE RUN WITH ALL CIRCUITS

LB-3

FIRE ALARM CONTROL PANEL

FIRE ALARM ANNUNCIATOR PANEL

ELECTRICAL WATER COOLER

ELECTRICAL METALLIC TUBING

EMPTY CONDUIT OR TUBING

DOUBLE POLE, SINGLE THROW

DOUBLE-POLE, DOUBLE THROW

ENGINE-GENERATOR SET

FULL LOAD AMPERE(S)

FLOOR

FURNISHED BY OWNER

FUSE(S)

EXISTING

ELECTRICAL MANHOLE

EMERGENCY

ELEVATION

ELECTRICAL HANDHOLE

DRAWING(S)

DISCONNECT

CURRENT TRANSFORMER(S)

DIRECT CURRENT

COMMUNICATIONS

CEILING

DIVISION

CONDUIT UNDERGROUND

DESIGNATION

MICROPHONE

ELECTRICAL CONVENTIONS

NATIONAL FIRE PROTECTION ASSOCIATION

ASSOCIATION

NATIONAL ELECTRICAL MANUFACTURER'S

NATIONAL ELECTRICAL CODE

NORMALLY CLOSED

MEGAWATT(S)

MEGAVOLT-AMPERE(S) REACTIVE

MEGAVOLT-AMPERE(S)

MANUAL TRANSFER SWITCH

MANUAL MOTOR STARTER

MILLIMETER(S)

MAIN LUGS ONLY

MINIMUM

METAL HALIDE

MOTOR CIRCUIT PROTECTOR

MOTOR CONTROL CENTER

MAIN CIRCUIT BREAKER

LOW PRESSURE SODIUM

MAXIMUM

METER(S)

LIGHTING

KILOVOLT-AMPERE(S) REACTIVE

KILOVOLT-AMPERE(S)

KILOWATT-HOUR(S)

KILOWATTS(S)

KILOAMPERE(S)

JUNCTION BOX

KILOVOLT(S)

INTERMEDIATE METALLIC CONDUIT

ISOLATED GROUND

OF NORTH AMERICA

ILLUMINATING ENGINEERING SOCIETY

CONDITIONING

HEATING, VENTILATION AND AIR

HIGH PRESSURE SODIUM

HORSEPOWER

HAND-OFF-AUTOMATIC

HIGH INTENSITY DISCHARGE

GROUND FAULT CIRCUIT INTERRUPT

FULL VOLTAGE, REVERSING

FULL VOLTAGE, NON-REVERSING

GROUND

FUSIBLE SAFETY SWITCH/FUSIBLE SWITCH

(ALL ABBREVIATIONS MAY NOT APPEAR ON DRAWINGS.)

ELECTRICAL ABBREVIATIONS

FLEXIBLE

GALVANIZED STEEL

SIZED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE (NEC)

MTR MOTOR

CONDUIT IN WALL

CONDUIT CAPPED OFF

CONDUIT CONTINUED

CONDUIT RUN UP

CONDUIT RUN DOWN

GROUND WIRE CONCEALED

GROUND SYSTEM

DOWNLIGHT FIXTURE

2X2 LIGHT FIXTURE

2X4LIGHT FIXTURE

CEILING MOUNTED CAMERA

CEILING MOUNTED SPEAKER

TELEVISION DEVICE JUNCTION BOX WITH 1" C. TO

ABOVE ACCESSIBLE CEILING

ELECTRIC HEATING COIL

RECEPTACLE ON EMERGENCY CIRCUIT. PROVIDE RED

OUTLET AND COVERPLATE

MOTOR

NON-FUSED DISCONNECT SWITCH (AMPS/POLES/NEMA

RATING)

TRANSFORMER

GROUND OR GROUND ROD AS NOTED

GROUND BAR

TELECOMMUNICATIONS TERMINAL BOARD

E3.01

AREA OF ENLARGED PLAN OR DETAIL

SHEET NO. ON

WHICH

ENLARGED

DETAIL IS DRAWN

DETAIL NUMBER

GRAPHIC SYMBOLS

SPECIAL PURPOSE RECEPTACLE - WALL MOUNTED

NEW CONSTRUCTION

EXISTING

DEMOLISHED

CEILING MTD VOICE/DATA DEVICE

CEILING MTD DUPLEX RECEPTACLE ON EMERGENCY

CIRCUIT. PROVIDE RED OUTLET AND COVERPLATEE

STRIP LIGHT FIXTURE

WALL MOUNT LIGHT FIXTURE

EMERGENCY LIGHT FIXTURE

CLG MTD EXIT LIGHT - SHADING INDICATEDS NUMBER OF

FACES. ARROWS INDICATE ORIENTATION

WALL MTD EXIT LIGHT - SHADING INDICATEDS NUMBER

OF FACES. ARROWS INDICATE ORIENTATION

POLE MTD SITE LIGHTING FIXTURE

BOLLARD LIGHT FIXTURE

GENERAL

NO HATCH INDICATES NORMAL POWER LIGHT FIXTURE

HALF SOLID INDICATES LIFE SAFETY LIGHT FIXTURE

ENTIRE STRIPED HATCH INDICATES CRITICAL LIGHT FIXTURE

LIGHTING SYMBOL LEGEND

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

GENERAL

a

- SUPERSCRIPT DENOTES FIXTURE BEING

CONTROLLED

- K - KEY OPERATED SWITCH

- T- TIMER SWITCH

- WP - WEATHERPROOF SWITCH

PHOTOCELL (MATCH CONTACTOR COIL VOLTAGE

AS REQUIRED)

PC

TC DIGITAL PROGRAMMABLE TIME CLOCK

OS WALL MTD OCCUPANCY SENSOR/SWITCH

CLG MTD OCCUPANCY SENSOROS

VS

CLG MTD VACANCY SENSORVS

WALL MTD VACANCY SENSOR/SWITCH

TOGGLE SWITCH - SPST

DIMMER SWITCH

WALL

ABOVE COUNTER

WP WEATHER PROOF

WHILE IN USE COVER

L1-10

PANEL NAME - CIRCUIT NUMBER

ELECTRICAL SYMBOL LEGEND

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

M

MOTOR RATED SWITCH

MS

MANUAL MOTOR STARTER

MAGNETIC STARTER OR CONTACTOR

JUNCTION BOXJ

PULLBOX PB

TELEPOWER/COMMUNICATIONS POLE

CEILING MOUNTED DUPLEX RECEPTACLE

DUPLEX RECEPTACLE

GROUND FAULT INTERRUPTION RECEPTACLE

ELECTRICAL SYMBOL LEGEND

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

DOUBLE DUPLEX RECEPTACLE

GROUND FAULT INTERRUPTION DOUBLE DUPLEX

RECEPTACLE

SPECIAL PURPOSE RECEPTACLE - FLOOR MOUNTED

DUPLEX RECEPTACLE PROTECTED BY GFI CIRCUIT

BREAKER

W TELECOMMUNICATIONS WALL MTD OUTLET WITH MINIMUM 1"

C. TO ABOVE CEILING, 48" AFF TO CENTER

TELECOMMUNICATIONS/DATA WALL OUTLET WITH

MINIMUM 1" C. TO ABOVE CEILING 18" TO CENTER UNO

TELEVISION DEVICE JUNCTION BOX WITH 1" C. TO ABOVE

ACCESSIBLE CEILING

TV

COMBINATION DISCONNECT SWITCH/MOTOR STARTER

(AMPS/POLES/FUSE RATING/NEMA RATING/STARTER SIZE)

FUSED DISCONNECT SWITCH (AMPS/POLES/FUSE

RATING/NEMA RATING)

30/3/1

30/3/25/3R

30/3/25/3R/00

VFD VARIABLE FREQUENCY DRIVE

ELECTRICAL PANEL ( SURFACE OR FLUSH MOUNTED AS

NOTED ON PANEL SCHEDULE AND DRAWINGS)

MISC. CONTROL PANEL (SURFACE OR FLUSH MOUNTED AS

NOTED ON DRAWINGS)

T

PUSH BUTTON MTD AT 48" TO CENTER UNO

WIREMOLD

CT

March 31, 2021

2 7

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

EA:CLIENT:

1 2 3 4 5 6 7 8

S

D ZIP

FORCE PROTECTION STREET ADDRESS

FORCE PROTECTION CITY AND ZIP

FORCE PROTECTION NAME

FORCE PROTECTION PH AND FAX

MEP STREET ADDRESS

MEP CITY AND ZIP

MEP ENGINEERS

MEP PH AND FAX

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CONSULTANT 01 NAME

CONSULTANT 01 PH AND FAX

FORCE PROTECTION CONTACT

ENAPAY, LLC

MEP CONTACT

ENAPAY, LLC

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

REVISION SCHEDULE

No. DESCRIPTION DATE

1331 RIVER BEND DRIVE

DALLAS, TEXAS 75247

MR. FRED C. CRABTREE, JR., P.E.

T. 214.696.6291

1255 CORPORATE DRIVE - SUITE 200

IRVING, TEXAS 75038

MR. MICHAEL BURCH

T. 469.242.4707

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CAMPOS ENGINEERING

ENAPAY, LLC

HILL INTERNATIONAL

PROJECT NUMBER:

BUILDING NUMBER:

EA:CLIENT:

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

WWW.ENAPAYLLC.COM

SITE PLAN AND LOCATION

DESIGN PRIMARY POWER

SECONDARY SIDE

5001 N. PIEDRAS / EL PASO, TEXAS 79930

VA EL PASO

5001 N. PIEDRAS

EL PASO, TEXAS 79930

MR. KEVIN ANGELES

756-16-110 EA03.0111

D

ES

IG

N

P R

IM

A

R Y

PO

W

ER

. S

EC

O

N D

A R

Y

SI

D E

IS

SU

E

FO

R C

O N

ST

R

U C

TI

O

N

PR

O

JE

C T

N U

M B

ER

: E

A

.0

E-1

F4F1

C1

PROJECT LOCATION

PROJECT SITE PLAN - DEMOLITION PROJECT SITE PLAN

MAIN ELECTRICAL ENTRANCE

AT CENTRAL PLANT

N PIEDRAS ST

T T

T

UGE UGE UGE

E U

EUEU

E U

E U

KEY NOTES

1. EXISTING RIO GRANDE ELECTRIC UTILITY TRANSORMERS TO BE

REMOVED.

2. EXISTING RIO GRANDE ELECTRIC UTILITY SWITCHGEAR TO BE REMOVED.

3. EXISTING BACKUP GENERATOR ROOM.

4. MAIN ELECTRICAL ROOM LOCATED IN BUILDING.

5. REMOVE AND RELOCATE LIGHT POLE.

6. EXISTING ELECTRICAL VAULT UNDER REMOVED TRANSFORMERS.

7. PROPOSED LOCATION OF EL PASO ELECTRIC 15 KV SWITCHGEAR.

8. PROPOSED LOCATION OF EL PASO ELECTRIC 2500 KVA TRANSFORMER.

9. 13.2 KV PRIMARY FEEDER FROM EL PASO ELECTRIC.

10. 13.2 KV PRIMARY FEED FROM SWITCH TO TRANSFORMER.

11. 480Y/277V SECONDARY SERVICE 8-4" CONDUITS IN DUCTBANK.

12. 480Y/277V SECONDARY SERVICE 16-4" CONDUITS IN DUCTBANK.

13. NEW UNDERGROUND ELECTRICAL MANHOLE.

14. REMOVE EXISTING WIRING AND REUSE EXISTING SERVICE CONDUITS TO

SWITCHBOARDS IN BUILDING.

15. RELOCATE ELECTRICAL SERVICE FOR CONDENSING UNIT TO ROOF; RE:

MECHANICAL.

16. MANHOLE FOR ELEVATION CHANGE.

17. PROVIDE 120 VAC/20 AMP CIRCUIT TO SUMP PUMP. PROVIDE 2#10,1#10,

3/4C FROM SPARE CIRCUIT IN PANEL IDCLA OR ICLLA IN EMERGENCY

DISTRIBUTION ROOM. UPDATE THE PANEL SCHEDULE AND USE

PHENOLIC TAG FOR CIRCUIT ID.

18. PROPOSED RELOCATED LIGHT POLE LOCATION.

19. ROUTING OF ELECTRICAL LINES HIGH VOLTAGE OR SECONDARY SHALL

MAINTAIN A MINIMUM DISTANCE OF 11'-6" FEET FROM THE CENTER OF

THE FUEL OIL ACCESS COVER.

SHEET NOTES

A. UNDERGROUND SECONDARY CONDUITS TO BE SCHEDULE 40 PVC MINIMUM WALL THICKNESS ENCASED IN A CONCRETE DUCTBANK WITH RED DYE ON TOP. FOR PRIMARY CONDUIT REQUIREMENTS CONTACT

EL PASO ELECTRIC.

B. COORDINATE ELECTRICAL UNDERGROUND WITH CROSSING UTILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE VERTICAL AND HORIZONTAL LOCATION OF ANY EXISTING UTILITIES

PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES.

C. UNDERGROUND ELECTRICAL PRIMARY (UGE) MEDIUM VOLTAGE DUCTBANKS AND SECONDARY

VOLTAGE (EU) DUCTBANKS SHALL BE INSTALLED BELOW GRADE AS INDICATED.

D. SECONDARY VOLTAGE MANHOLES SHALL BE TRAFFIC RATED H-20 LOADING WITH CAST IRON COVERS

AND CONDUIT TERMINATORS AS REQUIRED.

E. COORDINATE WITH EL PASO ELECTRIC FOR NEW PRIMARY FEEDER, SWITCHGEAR PAD, AND

TRANSFORER PAD REQUIREMENTS.

F. COORDINATE REMOVAL OF EXISTING TRANSFORMERS AND EXISTING SWITCHGEAR WITH RIO GRANDE

ELECTRIC.

G. FOR ANY DUCT BANKS TO REMAIN AND BE REUSED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR UTILIZING METHODS TO CAREFULLY REMOVE THE WIRING WITHOUT DAMAGING THE DUCT BANK. THE CONTRACTOR SHALL PROVIDE THE VA WITH A HAZARD ANALYSIS PLAN TO REMOVE THE WIRING. THE

PLAN SHALL BE APPROVED BY THE EOR AND VA PRIOR TO STARTING WORK.

H. PROVIDE AS-BUILT DRAWINGS PRIOR TO ENERGIZING THE NEW TRANSFORMERS AND WIRING.

I. THE CONTRACTOR SHALL PROVIDE A UTILITY SURVEY PLAN PRIOR TO STARTING WORK.

J. CONTRACTOR TO PERFORM A SITE EXPLORATION AND A SURVEY FOR GRADING PLAN. CONTRACTOR

SHALL PREPARE GRADING PLAN PRIOR TO COMMENCING WORK.

K. CONTRACTOR TO PULL SITE PERMIT FROM FORT BLISS DPW

L. CONTRACTOR TO COMPLY WITH ANY FORT BLISS DPW COMMENTS MADE ON PROPRIETARY WORK

ORDER AND EXCAVATION PERMIT.

M. CONTRACTOR TO OBTAIN HOT WORK PERMIT ON A DAILY BASIS THROUGH VA SAFETY OFFICE.

50'

SCALE

~100'

SCALE

T

S

E U

16 7

4 3

3 7

U G

E

U G

E U

G E

BLD 7781-B

BLD 7781

March 31, 2021

2021-03-31 fcrabtree Callout fcrabtree Cloud fcrabtree Text Box fcrabtree Text Box

NOTE:

1. PRIMARY ROUTING SHOWN FOR COORDINATION PURPOSES ONLY. CONTRACTOR SHALL COORDINATE WITH NEW UTILITY DUCT BANKS

2. CONTRACTOR TO COORDINATE BI-DIRECTIONAL METER WITH EL PASO ELECTRIC FOR SERVICE FEEDING MSA fcrabtree Cloud fcrabtree Text Box fcrabtree Text Box 2021-11-18 fcrabtree Text Box fcrabtree Text Box

ADDENDUM 1

fcrabtree Text Box 2021-11-19 fcrabtree Text Box

ADDENDUM 1

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

EA:CLIENT:

1 2 3 4 5 6 7 8

S

D ZIP

FORCE PROTECTION STREET ADDRESS

FORCE PROTECTION CITY AND ZIP

FORCE PROTECTION NAME

FORCE PROTECTION PH AND FAX

MEP STREET ADDRESS

MEP CITY AND ZIP

MEP ENGINEERS

MEP PH AND FAX

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CONSULTANT 01 NAME

CONSULTANT 01 PH AND FAX

FORCE PROTECTION CONTACT

ENAPAY, LLC

MEP CONTACT

ENAPAY, LLC

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

REVISION SCHEDULE

No. DESCRIPTION DATE

1331 RIVER BEND DRIVE

DALLAS, TEXAS 75247

MR. FRED C. CRABTREE, JR., P.E.

T. 214.696.6291

1255 CORPORATE DRIVE - SUITE 200

IRVING, TEXAS 75038

MR. MICHAEL BURCH

T. 469.242.4707

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CAMPOS ENGINEERING

ENAPAY, LLC

HILL INTERNATIONAL

PROJECT NUMBER:

BUILDING NUMBER:

EA:CLIENT:

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

WWW.ENAPAYLLC.COM

VA EL PASO

5001 N. PIEDRAS

EL PASO, TEXAS 79930

MR. KEVIN ANGELES

ONE LINE DRAWINGS DESIGN PRIMARY POWER

SECONDARY SIDE

5001 N. PIEDRAS / EL PASO, TEXAS 79930

756-16-110 EA03.0111

D

ES

IG

N

P R

IM

A

R Y

PO

W

ER

. S

EC

O

N D

A R

Y

SI

D E

E-2

3000A3000A

SHEET NOTES

A. COORDINATE WITH EL PASO ELECTRIC FOR SERVICE AND METER

REQUIREMENTS. INSTALLATION SHALL CONFORM WITH EL PASO

ELECTRIC UTILITY GUIDELINES, THE NATIONAL ELECTRICAL CODE (NEC),

AND THE AUTHORITY HAVING JURISDICTION (AHJ).

B. GROUNDING AND BONDING SHALL CONFORM WITH ARTICLE 250 OF THE

NEC.

C. THE LAYOUT OF NEW AND EXISTING EQUIPMENT TO BE REUSED IS

DIAGRAMMATIC. FIELD VERIFY DISTANCES, SITE CONDITIONS, THE

LOCATION OF EXISTING EQUIPMENT AND THE LOCATION AND SPACING

OF NEW EQUIPMENT PRIOR TO BID AND PERFORMING WORK. PROVIDE

ALL LABOR AND MATERIALS FOR A COMPLETE INSTALLATION.

D. VERIFY LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. HAND DIG

TO IDENTIFY EXISTING UTILITIES PRIOR TO DEMOLITION OR

INSTALLATION. USE CAUTION DURING EXCAVATION TO NOT DAMAGE OR

DISRUPT EXISTING UTILITIES.

E. COORDINATE WITH EL PASO ELETRIC FOR FINAL TERMINATIONS ON

SECONDARY SIDE OF UTILITY TRANSFORMERS.

KEY NOTES

1. 15 KV FEEDER BY EL PASO ELECTRIC. PROVIDE CONDUITS AS REQUIRED

BY EL PASO ELECTRIC.

2. EIGHT (8) SETS OF 4#500 KCMIL IN 4"C

3. EIGHT (8) SETS OF 4#500 KCMIL IN EXISTING CONDUIT

4. VERIFY SERVICE ENTRANCE AT EXISTING SWITCHBOARD AND CONNECT

NEUTRAL TO GROUND.

13.2 KV EL PASO

ELECTRIC FEEDER

EL PASO ELECTRIC

15 KV SWITCHGEAR

2000 KVA

13.2 KV TO 480Y/277V

EL PASO ELECTRIC

TRANSFORMER 1

2000 KVA

13.2 KV TO 480Y/277V

EL PASO ELECTRIC

TRANSFORMER 2

ELECTRICAL

MANHOLE

(NEW)

ELECTRICAL

MANHOLE

(NEW)

ELECTRICAL

MANHOLE

(NEW)

ELECTRICAL

VAULT

(EXISTING)

3000A/3P3000A/3P

MAIN SWITCHBOARD MSB 480Y/277V 3000A

(EXISTING)

MAIN SWITCHBOARD MSA 480Y/277V 3000A

(EXISTING)

ONE LINE DIAGRAM

F3

2 2

IS

SU

E

FO

R C

O N

ST

R

U C

TI

O

N

PR

O

JE

C T

N U

M B

ER

: E

A

.0

4 7

March 31, 2021

2021-03-31 fcrabtree Cloud fcrabtree Line fcrabtree Line fcrabtree Text Box fcrabtree Text Box 2021-11-18 fcrabtree Text Box fcrabtree Text Box

ADDENDUM 1

fcrabtree Text Box 2021-11-19 fcrabtree

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

EA:CLIENT:

1 2 3 4 5 6 7 8

S

D ZIP

FORCE PROTECTION STREET ADDRESS

FORCE PROTECTION CITY AND ZIP

FORCE PROTECTION NAME

FORCE PROTECTION PH AND FAX

MEP STREET ADDRESS

MEP CITY AND ZIP

MEP ENGINEERS

MEP PH AND FAX

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CONSULTANT 01 NAME

CONSULTANT 01 PH AND FAX

FORCE PROTECTION CONTACT

ENAPAY, LLC

MEP CONTACT

ENAPAY, LLC

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

REVISION SCHEDULE

No. DESCRIPTION DATE

1331 RIVER BEND DRIVE

DALLAS, TEXAS 75247

MR. FRED C. CRABTREE, JR., P.E.

T. 214.696.6291

1255 CORPORATE DRIVE - SUITE 200

IRVING, TEXAS 75038

MR. MICHAEL BURCH

T. 469.242.4707

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CAMPOS ENGINEERING

ENAPAY, LLC

HILL INTERNATIONAL

PROJECT NUMBER:

BUILDING NUMBER:

EA:CLIENT:

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

WWW.ENAPAYLLC.COM

SCHEDULES AND DETAILS DESIGN PRIMARY POWER

SECONDARY SIDE

5001 N. PIEDRAS / EL PASO, TEXAS 79930

VA EL PASO

5001 N. PIEDRAS

EL PASO, TEXAS 79930

MR. KEVIN ANGELES

756-16-110 EA03.0111

D

ES

IG

N

P R

IM

A

R Y

PO

W

ER

. S

EC

O

N D

A R

Y

SI

D E

IS

SU

E

FO

R C

O N

ST

R

U C

TI

O

N

PR

O

JE

C T

N U

M B

ER

: E

A

.0

E-3

C5

POWER MANHOLE DETAILS

NTS

F7

UNDERGROUND CONCRETE

PULLBOX - PAVED AREAS

NTSF5

MANHOLE GROUNDING DETAIL

NTSF3

DUCT BANK DETAILS

NTSF1

GROUNDING BAR DETAIL

NTS

5 7

GENERAL NOTES:

1. HARDWARE SHALL BE STAINLESS STEEL. GROUND BAR SHALL BE COPPER (CU)

AS NOTED ABOVE.

2. PROVIDE 1 MOUNTING POINT PER 305mm (12") OF BAR LENGTH.

3. HOLES MAY BE ADDEDD IF REQUIRED.

GRADE

LIGHTING CIRCUIT UP POLE

(TYPICAL ALL CONDUCTORS).

BOND SYSTEM GROUND TO

GROUNDING LUG INSIDE.

No.6 GROUND CONDUCTOR.

GROUT POLE BASE.

1" CHAMFER.

PVC CONDUITS.

#6 AWG

CADWELD CONNECTION

TO GROUND ROD.

PVC CONDUIT FOR CIRCUIT

CONTINUATION.

COPPERWELD GROUND

ROD, 5/8" x 8'-0".

FOUNDATION DESIGNED BY

STRUCTURAL ENGINEER,

REFERENCE STRUCTURAL

PLANS

PVC CONDUIT FOR CIRCUIT

CONTINUATION.

ANCHOR BOLTS (4).

LEVELING NUT.

2'-6" MINIMUM

REUSE EXISTING LUMINAIRE

REUSE EXISTING LUMINAIRE POLE

NOTES:

1. DO NOT CAST GROUND CONDUCTOR IN CONCRETE BASE WITHOUT RACEWAY.

2. LEVELING NUTS SHALL BE USED. POLE BEARING PLATE SHALL NOT BE SHIMMED AGAINST PIER CONCRETE.

3. FOR LIGHT POLES LOCATED ON HERB KELLEHER LOCATE THE RECEPTACLE ON THE NORTH SIDE OF THE POLE WHEN DRIVING TOWARD THE TERMINAL. LOCATE THE RECEPTACLE ON THE SOUTH SIDE OF THE POLE WHEN DRIVING FROM THE TERMINAL. PROVIDE RECEPTACLES FOR LIGHT POLES CIRCUITED FROM ELECTRICAL

PANELS 2 AND 3. REFER TO ELECTRICAL PLANS AND SCHEDULES ON SHEET E6.01.

POLE BASE TO EXTEND

6" ABOVE GRADE.

PVC CONDUITS

6"

3"

C3

POLE BASE DETAIL

NTS

March 31, 2021

2021-03-31 fcrabtree Snapshot fcrabtree Text Box C1 fcrabtree PolyLine fcrabtree Text Box

POLE BASE DETAIL

fcrabtree Text Box

NTS

fcrabtree Text Box

PER DETAIL C1

fcrabtree Cloud fcrabtree Text Box fcrabtree Polygon fcrabtree Cloud fcrabtree Text Box fcrabtree Text Box 2021-11-18 fcrabtree Text Box fcrabtree Text Box

ADDENDUM 1

fcrabtree Text Box 2021-11-19 fcrabtree

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

EA:CLIENT:

1 2 3 4 5 6 7 8

S

D ZIP

FORCE PROTECTION STREET ADDRESS

FORCE PROTECTION CITY AND ZIP

FORCE PROTECTION NAME

FORCE PROTECTION PH AND FAX

MEP STREET ADDRESS

MEP CITY AND ZIP

MEP ENGINEERS

MEP PH AND FAX

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CONSULTANT 01 NAME

CONSULTANT 01 PH AND FAX

FORCE PROTECTION CONTACT

ENAPAY, LLC

MEP CONTACT

ENAPAY, LLC

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

REVISION SCHEDULE

No. DESCRIPTION DATE

1331 RIVER BEND DRIVE

DALLAS, TEXAS 75247

MR. FRED C. CRABTREE, JR., P.E.

T. 214.696.6291

1255 CORPORATE DRIVE - SUITE 200

IRVING, TEXAS 75038

MR. MICHAEL BURCH

T. 469.242.4707

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CAMPOS ENGINEERING

ENAPAY, LLC

HILL INTERNATIONAL

PROJECT NUMBER:

BUILDING NUMBER:

EA:CLIENT:

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

WWW.ENAPAYLLC.COM

MECHANICL SYMBOLS AND

GENERAL NOTES

DESIGN PRIMARY POWER

SECONDARY SIDE

5001 N. PIEDRAS / EL PASO, TEXAS 79930

VA EL PASO

5001 N. PIEDRAS

EL PASO, TEXAS 79930

MR. KEVIN ANGELES

756-16-110 EA03.0111

D

ES

IG

N

P R

IM

A

R Y

PO

W

ER

. S

EC

O

N D

A R

Y

SI

D E

IS

SU

E

FO

R C

O N

ST

R

U C

TI

O

N

PR

O

JE

C T

N U

M B

ER

: E

A

.0

N

SCALE:

COCO

S

MM

S S

M M

M M

H

T

CO2

M

R

CO

VFD

R D R D

FD

FSD

SD

FD

SD

BDD

BDD

FSD

SP

SP

S S

M M

T T

H H

CO2

CO2

B B

DP

DP

DPS

DPS

AF

AF

CRD

SHEET 1/8" = 1'-0"

TOP TITLE

BOTTOM TITLE

F&T F&T

DUCTWORK SYMBOLSVALVE SYMBOLS

GATE VALVE

PIPE & FITTING SYMBOLS

MANUAL VOLUME DAMPER

GRAPHIC SYMBOLS

CONTROL SYMBOLS

VERTICAL RUN ON PLAN

READ LEFT TO RIGHT

4" CWS

H W

R C

W R

H W

S

2" HWS

2" HWR

4" CWR

READ TOP TO BOTTOM

4" CHWS

3" PCD(F) *

2" HPS

2" LPS

4" CHWR

C W

S

3" PCD(F) *

2" HPS

2" LPS

4" CHWR

4" CHWS

L P

S C

H W

R C

H W

S P

C D

(F

CHWS

CHWR

LPS

PCD(F) *

HWS

HWR

CWR

H P

S

HPS

CWS

PIPING DESIGNATION

2" CHWS

XXX-1

SYSTEM SERVICE ABBREVIATION

NOMINAL PIPE SIZE

MISCELLANEOUS SYMBOLS

EQUIPMENT DESIGNATION

(IN INCHES)

SINGLE LINE PIPE/DUCTWORK BREAK

KEYED NOTE

POINT OF DISCONNECTION

POINT OF CONNECTION (NEW TO EXISTING)

HORIZONTAL RUN ON PLAN

MULTI-LINE KEY

4" CWR

4" CWS

2" HWS

2" HWR

(D)

(R)

(E)

(N)

LIMIT OF EXISTING ITEMS TO BE REMOVED

NEW ITEM (NOTATION SHOWN AS NECESSARY

FOR CLARIFICATION)

EXISTING ITEM TO REMAIN (NOTATION

SHOWN AS NECESSARY FOR CLARIFICATION)

EXISTING ITEM TO BE RELOCATED (NOTATION

SHOWN AS NECESSARY FOR CLARIFICATION)

EXISTING ITEM TO BE DEMOLISHED (NOTATION

SHOWN AS NECESSARY FOR CLARIFICATION)

EXISTING ITEMS TO BE DEMOLISHED

EXISTING ITEMS TO REMAIN

NEW ITEMS (PIPING/DUCTWORK/EQUIPMENT)

RECTANGULAR DUCT/STANDARD BREAK

* - (F) INDICATES FUTURE PIPING ON RACK

BOP 12'-6"

AFF

LOWER

PIPE RACK

BOP 13'-6"

AFF UPPER

PIPE RACK

BOP 12'-6"

AFF

LOWER

PIPE RACK

BOP 13'-6"

AFF UPPER

PIPE RACK

SINGLE LINEDOUBLE LINE

PIPE

WELDED JOINT

SCREWED JOINT

GROOVED END JOINT

FLANGED JOINT

GROOVED END ADAPTER FLANGE

FLANGED COUPLING ADAPTER

UNION

TEE FITTING

REDUCER - ECCENTRIC

REDUCER - CONCENTRIC

CAP

ANCHOR

BLIND FLANGE

FLOW ORIFICE PLATE

ELBOW, 90 DEGREE -

CHANGE IN

DIRECTION

TOWARD VIEWER

ELBOW, 90 DEGREE -

CHANGE IN

DIRECTION

AWAY FROM VIEWER

LATERAL

NOTE:

WELDED FITTINGS ARE SHOWN FOR DOUBLE LINE PIPING.

FITTINGS WITH OTHER END CONDITIONS ARE SIMILAR.

PRESSURE GAUGE

WITH

GAUGE COCK

STEAM TRAP, TYPE AS NOTED

IB = INVERTED BUCKET

F&T = FLOAT &

THERMOSTATIC

TH = THERMODYNAMIC

BP = BALANCED PRESSURE

AIR SEPARATOR

ELBOW, 90 DEGREE

(LONG RADIUS

UON)

ELBOW, 45 DEGREE

(LONG RADIUS

UON)

VENTURI FLOW METER

CONTROL VALVES

CLEANOUT

(F) FUTURE ITEM (NOTATION SHOWN AS

NECESSARY FOR CLARIFICATION)

2"

SECTION NO.

DIRECTION OF CUTTING PLANE

SHEET NO. ON WHICH

THE SECTION IS

DRAWN

A

M5.01

DRAWING TITLE

DETAIL NO. AND SHEET NO.

SCALE OF FLOOR PLAN,

SECTION OR DETAIL

M3.01

AREA OF ENLARGED PLAN

OR

DETAIL

SHEET NO. ON

WHICH

ENLARGED

DETAIL IS DRAWN

CHWS

DOUBLE LINE PIPE/ROUND DUCTWORK BREAK

NEW CONNECTION TO EXISTING ITEM

1 REVISION DELTA

STUB END OR FLANGE

ADAPTER W/ FLANGE RING

GENERIC FLEXIBLE

COUPLING

(REFER TO SPECIFICATIONS)

2"CHWS

- OR -

TEE FITTING,

BRANCH TOWARD VIEWER

TEE FITTING,

BRANCH AWAY FROM VIEWER

PIPING WITH INSULATION

(WHEN SHOWN FOR

CLARITY)

THERMOWELL

WITH

THERMOMETER

STRAINER - "Y"

TYPE

WITH BLOW DOWN

WATER METER

PUMP, ARROW INDICATES FLOW

SINGLE LINEDOUBLE LINEDESCRIPTION DESCRIPTION

CHECK VALVE

BUTTERFLY VALVE

BALL VALVE

DIAPHRAGM VALVE

GLOBE VALVE

PLUG VALVE

PRESSURE REDUCING VALVE

BALANCING VALVE

DIRECTION OF FLOW / SLOPE

PRESSURE RELIEF VALVE

AUTOMATIC AIR VENT

MANUAL AIR VENT

SINGLE LINEDOUBLE LINE DESCRIPTION

TWO-WAY, TWO POSITION

CONTROL VALVE W/ SOLENOID

TWO-WAY, MODULATING

CONTROL VALVE

TWO-WAY, TWO POSITION

CONTROL VALVE

THREE-WAY, TWO POSITION

CONTROL VALVE

THREE-WAY, MODULATING

CONTROL VALVE

WALL MOUNTED DEVICES

HUMIDITY SENSOR/HUMIDISTAT

TEMPERATURE SENSOR/THERMOSTAT

CARBON DIOXIDE SENSOR

MOTION SENSOR

OVERRIDE SWITCH

CARBON MONOXIDE SENSOR

VARIABLE FREQUENCY DRIVE

EQUIPMENT SYMBOLS

ROOFTOP EXHAUST FAN (ROOF PLAN VIEW)

ROOFTOP EXHAUST FAN (ROOF PLAN VIEW)

WALL LOUVER WITH POSITIVE OR NEGATIVE AIRFLOW

DOOR UNDERCUT (SPECIFY CFM IF REQUIRED)UC

DOOR LOUVER (SPECIFY CFM IF REQUIRED)

LD

AxB

RECTANGULAR OR SQUARE DUCT,

DIMENSIONS ARE IN INCHES, MIN.

INSIDE CLEAR, A = WIDTH, B= HEIGHT

AxB

A"Ø

ROUND DUCT DIMENSIONS ARE IN

INCHES, MIN. INSIDE CLEAR,

A = DIAMETER

A"Ø

AxBØ

FLAT OVAL DUCT DIMENSIONS ARE

IN INCHES, MIN. INSIDE CLEAR,

A = WIDTH, B= HEIGHT

AxBØ

DUCTWORK RISE (R) OR DROP (D)

RELATIVE TO DIRECTION OF

AIRFLOW

DIRECTION OF AIR FLOW

SUPPLY AIR OR POSITIVE

PRESSURE DUCTWORK, SECTION

TOWARDS/AWAY VIEWER

RETURN AIR OR NEGATIVE

PRESSURE DUCTWORK, AIRFLOW

TOWARDS VIEWER

EXHAUST AIR DUCTWORK,

AIRFLOW TOWARDS VIEWER

RIGID ROUND DUCTWORK,

AIRFLOW TOWARDS VIEWER

FIRE DAMPER

FIRE/SMOKE DAMPER

SMOKE DAMPER

BACKDRAFT DAMPER

SMOKE DETECTOR

STATIC PRESSURE SENSOR

MOTORIZED DAMPER

TEMPERATURE SENSOR

DESCRIPTIONSINGLE LINEDOUBLE LINE

HUMIDITY SENSOR

CARBON DIOXIDE SENSOR

BAROMETRIC DAMPER

DIFFERENTIAL PRESSURE SENSOR

DIFFERENTIAL PRESSURE

SAFETY SHUT-DOWN

RELAY

AIRFLOW PROOF SWITCH

ACCESS PANEL/CLEANOUT

SUPPLY AIR OR POSITIVE

PRESSURE DUCTWORK, AIRFLOW

AWAY FROM VIEWER

RETURN AIR OR NEGATIVE

PRESSURE DUCTWORK, AIRFLOW

AWAY FROM VIEWER

EXHAUST AIR DUCTWORK,

AIRFLOW AWAY FROM VIEWER

RIGID ROUND DUCTWORK,

AIRFLOW AWAY FROM

VIEWER

TRANSITION - ECCENTRIC REDUCER

TRANSITION - CONCENTRIC REDUCER

TRANSITION - SQUARE TO ROUND

90° ELBOW WITHOUT TURNING

VANES (RETURN OR EXHAUST

DUCTWORK ONLY)

90° ELBOW WITH TURNING VANES

(REQUIRED ON SUPPLY

DUCTWORK)

45° ELBOW WITHOUT TURNING

VANES (RETURN OR EXHAUST

DUCTWORK ONLY)

45° ELBOW WITH TURNING VANES

(REQUIRED ON SUPPLY DUCTWORK)

RADIUS 90° ELBOW (R = 1.5W)

RW

RADIUS 45° ELBOW (R = 1.5W)

RW

SPIN-IN FITTING WITH FLEXIBLE

DUCTWORK, DIMENSIONS ARE IN

INCHES, MIN. INSIDE CLEAR,

A = DIAMETER

AIR DISTRIBUTION

CEILING RADIATION DAMPER

LINEAR SLOT DIFFUSER

ROUND SUPPLY AIR DIFFUSER

SIDEWALL REGISTER

8"Ø

TYP OF 2

AIR DISTRIBUTION CALLOUT

RETURN AIR OR TRANSFER AIR GRILLE

A"ØA"Ø

INLINE EXHAUST FAN (EF), AIR HANDLING UNIT

(AHU), CONDENSING UNIT (CU)

BRANCH TAKE-OFF WITH MVD

CONICAL TAKE-OFF WITH MVD

DUCTWORK SYMBOLS

SINGLE LINEDOUBLE LINE DESCRIPTION

SUPPLY AIR DIFFUSER

EXHAUST AIR GRILLE

REFER TO SCHEDULE FOR ADDITIONAL INFORMATION

DUCT MOUNTED GRILLE

DETAIL NUMBER

MECHANICAL SYMBOL LEGEND

THIS IS A STANDARD LEGEND SHEET. SOME INFORMATION ON

THIS SHEET MAY NOT NECESSARILY APPLY TO THIS PROJECT.

S1

MECHANICAL GENERAL NOTES

1. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT EQUIPMENT CONNECTIONS.

2. PIPING CONNECTIONS TO ALL EQUIPMENT SHALL BE FABRICATED WITH THE ISOLATION VALVES, FLANGES AND/OR UNIONS

POSITIONED TO ALLOW REMOVAL AND SERVICE OF THE COMPONENT PARTS.

3. INSTALL MANUAL AIR VENTS AT THE HIGH POINTS OF THE PIPING SYSTEMS.

4. ROUTE PIPING IN AN ORDERLY MANNER AND MAINTAIN PROPER GRADES. INSTALL TO CONSERVE HEADROOM AND TO CREATE

MINIMUM INTERFERENCE WITH USE OF SPACE. ROUTE ALL PIPING PARALLEL TO BUILDING LINES UON. GROUP PIPING AT COMMON

BOP ELEVATIONS WHENEVER PRACTICAL. PIPES LOCATED IN CONCEALED SPACES SHALL BE ROUTED CLOSE TO BUILDING

STRUCTURE UON.

5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE OR EQUIPMENT CONNECTED.

6. INSTALL VALVES WITH STEMS UPRIGHT OR HORIZONTAL, NOT INVERTED.

7. INSTALL VALVES AND EQUIPMENT IN ACCESSIBLE LOCATIONS. INSTALL ACCESS DOORS IN PARTITIONS OR CEILINGS WHERE VALVES

AND EQUIPMENT WOULD OTHERWISE BE INACCESSIBLE.

8. WHEN SOCKET WELD OR SOLDER END VALVES ARE INSTALLED, SPECIAL CARE SHALL BE TAKEN TO AVOID OVERHEATING AND

DAMAGING THE VALVE BODY, TRIM OR PACKING. DAMAGED VALVES SHALL BE REPLACED AT CONTRACTOR'S EXPENSE.

9. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.

10. SLEEVE ALL PIPING THAT PENETRATES FIRE RATED WALLS, FLOORS AND PARTITIONS. PENETRATIONS SHALL BE SEALED WITH A U.L.

LISTED ASSEMBLY TO PROVIDE A RATING EQUAL TO OR GREATER THAN THAT OF THE PENETRATED WALL, FLOOR OR PARTITION.

11. SLEEVE ALL PIPING THAT PENETRATES EXTERIOR BUILDING WALLS AND GRADE BEAMS. SEAL PENETRATIONS WATERTIGHT.

12. COORDINATE WITH OTHER TRADES BEFORE FABRICATION OR INSTALLATION OF ANY SYSTEMS.

13. EXISTING DUCTWORK, PIPING AND EQUIPMENT SHOWN ON THESE DRAWINGS INDICATES THE GENERAL LOCATION AND ROUTING. THE

ACTUAL LOCATION SHALL BE DETERMINED BY THE CONTRACTOR WHO SHALL COORDINATE ALL WORK WITH ALL TRADES NECESSARY

TO INSTALL NEW DUCTWORK, PIPING OR EQUIPMENT AS SHOWN ON THE DRAWING.

14. THESE DRAWINGS DO NOT NECESSARILY SHOW ALL OFFSETS OR ELEVATION DIFFERENCES WHICH MAY BE NECESSARY FOR THE

COMPLETE INSTALLATION. THESE SHALL BE PROVIDED AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONAL SYSTEM AT NO

ADDITIONAL COST TO THE CONTRACT.

15. ALL NEW DUCTWORK SHALL BE EXTERNALLY INSULATED AS SPECIFIED.

16. WHERE REMOVAL OF EXISTING DUCTWORK OR PORTIONS OF ANY AIR SYSTEM IS NECESSARY, THE DUCT SHALL BE PATCHED AND

SEALED AIRTIGHT USING PATCH OF SAME MATERIAL AND EQUAL OR GREATER THICKNESS AS EXISTING. PATCHES SHALL BE

ATTACHED WITH SHEET METAL SCREWS OR OTHER MEANS OF POSITIVE ATTACHMENT (WELDING, BONDING, ETC.) AS SPECIFIED FOR

THE PARTICULAR DUCT SYSTEM. NEW INSULATION SHALL BE EQUAL TO OR BETTER THAN EXISTING AND SHALL BE PATCHED AND

SEALED TO MATCH EXISTING INSULATION AND MAINTAIN VAPOR BARRIER.

17. COORDINATE ALL REMODEL WORK WITH NEW CONSTRUCTION AND OTHER TRADES.

18. THE CONTRACTOR SHALL ADJUST AND BALANCE ALL MECHANICAL SYSTEMS TO DESIGN SETTINGS AS SHOWN AND SHALL

REBALANCE TO RESTORE SETTINGS OF SYSTEMS TEMPORARILY ALTERED FOR THE PURPOSES OF COMPLETING THE WORK OF THIS

PROJECT.

19. NOTIFY AND COORDINATE WITH THE OWNER AT LEAST SEVEN DAYS PRIOR TO SHUTDOWN OF ANY BUILDING SERVICES OR

EQUIPMENT. SHUTDOWN TIME SHALL BE KEPT TO A MINIMUM.

20. ANY ITEMS DAMAGED DURING DEMOLITION SHALL BE REPLACED WITH NEW MATERIALS TO MATCH EXISTING.

21. CONTRACTOR SHALL PROVIDE TEMPORARY DUCTWORK, ELECTRICAL SERVICE, PIPING OR OTHER BUILDING SERVICES AS REQUIRED

TO KEEP OTHER AREAS IN OPERATION DURING REMODELING. NOTIFY OWNER PRIOR TO SHUT-DOWN FOR ANY TEMPORARY SERVICE

REQUIREMENTS. ALL TEMPORARY WORK SHALL BE COMPLETELY REMOVED ONLY AFTER NEW SERVICES ARE COMPLETELY

INSTALLED AND FUNCTIONAL.

22. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF CEILING-MOUNTED HVAC DEVICES AND EQUIPMENT.

23. DUCT ROUTING CHANGES MADE BY THE CONTRACTOR FOR THE PURPOSE OF ACCOMMODATING FIELD CONDITIONS SHALL INCLUDE

FIRE DAMPERS AND COMBINATION FIRE/SMOKE DAMPERS IN RATED PARTITIONS AS SHOWN IN ORIGINAL ROUTING ARRANGEMENTS.

24. FURNISH AND INSTALL ACCESS DOORS (AD) IN THE DUCTWORK IMMEDIATELY ADJACENT TO EACH FIRE DAMPER AND EACH

FIRE/SMOKE DAMPER. PARTITIONS SHALL BE PROVIDED WITH ACCESS DOORS TO PROVIDE SERVICE AND ACCESS TO DAMPER

ACCESS DOORS.

25. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE REQUIRED BY CODE. FIRE, SMOKE, AND COMBINATION FIRE/SMOKE

DAMPERS SHALL BE UL LISTED, SHALL BEAR THE UL LABEL AND SHALL COMPLY WITH NFPA BULLETIN NO. 90A. FULLY-OPEN DAMPERS

SHALL NOT HAVE ANY PROJECTIONS INTO THE AIRSTREAM.

26. ABANDONED DUCT SHALL BE REMOVED WHERE INDICATED ON THE DRAWINGS. DUCT REMAINING IN PLACE SHALL BE CAPPED, SEALED AIR TIGHT AT POINT(S) OF DEMOLITION, AND INSULATED TO MATCH EXISTING..

27. NEW HOLES THROUGH EXISTING FLOORS SHALL BE CORE DRILLED. ALL CORES SHALL BE X-RAYED PRIOR TO CORING.

28. ALL DUCT SIZES SHOWN HEREIN REPRESENT INSIDE CLEAR DIMENSIONS. EXTERNAL SHEET METAL DIMENSIONS OF DUCTWORK

THAT IS SPECIFIED TO BE INTERNALLY LINED SHALL BE ADJUSTED BY THE CONTRACTOR TO ALLOW FOR THICKNESS OF LINING.

29. THE OWNER SHALL HAVE THE OPTION TO DESIGNATE ANY MATERIALS REMOVED OR DEMOLISHED DURING THIS WORK AS

"RECYCLABLE" AND SHALL HAVE FINAL DISPOSITION OVER THE DISPOSAL OF THESE MATERIALS. ALL MATERIALS

REMOVED/DEMOLISHED BY THE CONTRACTOR FOR THIS JOB AND NOT RETAINED BY THE OWNER FOR RECYCLING OR OTHER

PURPOSES SHALL BE DISPOSED OFF-SITE BY THE CONTRACTOR.

30. THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL OF ANY EQUIPMENT DESIGNATED FOR REMOVAL. THE OWNER SHALL PROVIDE A

LIST OF ITEMS THEY REQUIRE TO BE SALVAGED PRIOR TO THE START OF DEMOLITION. THE CONTRACTOR SHALL REMOVE THESE

ITEMS USING REASONABLE CARE TO MINIMIZE DAMAGE.

31. ANY AND ALL WATER CONNECTIONS MADE FOR THE PURPOSE OF CLEANING TOOLS OR THE WORK AREA OR FOR ANY OTHER

CONSTRUCTION-RELATED PURPOSES SHALL BE MADE ONLY TO DOMESTIC WATER HOSE BIBBS OR TO CONTRACTOR-SUPPLIED

WATER SOURCES. APPROVED BACKFLOW PREVENTION DEVICES SHALL BE USED AS REQUIRED BY THE AUTHORITY HAVING

JURISDICTION. CONNECTIONS SHALL NOT BE MADE TO FIRE WATER, CHILLED WATER, CONDENSER WATER, HEATING HOT WATER, DOMESTIC HOT WATER OR ANY OTHER TREATED WATER SOURCE UNLESS REQUIRED AS PART OF WORK ON THESE SYSTEMS.

32. EXCEPT WHERE REQUIRED AT EQUIPMENT NOZZLES, FLANGES SHALL BE RAISED FACE WELD-NECK.

33. INSTALL DIELECTRIC FITTINGS AT ALL FERROUS PIPE CONNECTIONS TO NON-FERROUS METALLIC PIPE OR EQUIPMENT.

34. BULLHEAD TEES SHALL NOT BE USED TO JOIN CONVERGING (RETURN) FLOWS, REGARDLESS OF ARRANGEMENT SHOWN ON PLANS.

35. PROVIDE ESCUTCHEON PLATES WHERE PIPES EXPOSED TO VIEW PENETRATE FINISHED WALLS, FLOORS AND CEILINGS. SPLIT-RING

ESCUTCHEON PLATES SHALL NOT BE USED UON.

36. PROVIDE CAPPED DRAIN VALVES AT LOW POINTS OF PIPING SYSTEMS AND AT EQUIPMENT CONNECTIONS. PROVIDE HOSE BIBB

CONNECTIONS WITH CAPS AT DRAIN VALVES WHICH DO NOT DISCHARGE DIRECTLY OVER OR ARE NOT PIPED DIRECTLY TO AN

APPROPRIATE DRAIN.

37. PIPING, DUCTWORK OR EQUIPMENT CONNECTIONS OPENED BY DEMOLITION OR RENOVATION SHALL BE TEMPORARILY SEALED TO

KEEP OUT FOREIGN MATTER UNTIL SUCH TIME AS RECONNECTIONS ARE MADE.

M-1 6 7

March 31, 2021

If this sheet is not 30" by 42", it is a reduced print; and thus, must be scaled accordingly.

A

1 2 3 4 5 6 7 8

B

C

D

E

F

A

B

C

D

E

F

OFFICE OF

FACILITIES

MANAGEMENT

PROJECT NUMBER:

BUILDING NUMBER:

VA DRAWING NUMBER:

DWG ____ OF ____

PROJECT TITLE:

LOCATION:

DATE: CHECKED: DRAWN:

DRAWING TITLE:

APPROVED: PROJECT DIRECTOR

PROJECT DIRECTORY:DESCRIPTION:

EA:CLIENT:

1 2 3 4 5 6 7 8

S

D ZIP

FORCE PROTECTION STREET ADDRESS

FORCE PROTECTION CITY AND ZIP

FORCE PROTECTION NAME

FORCE PROTECTION PH AND FAX

MEP STREET ADDRESS

MEP CITY AND ZIP

MEP ENGINEERS

MEP PH AND FAX

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CONSULTANT 01 NAME

CONSULTANT 01 PH AND FAX

FORCE PROTECTION CONTACT

ENAPAY, LLC

MEP CONTACT

ENAPAY, LLC

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

REVISION SCHEDULE

No. DESCRIPTION DATE

1331 RIVER BEND DRIVE

DALLAS, TEXAS 75247

MR. FRED C. CRABTREE, JR., P.E.

T. 214.696.6291

1255 CORPORATE DRIVE - SUITE 200

IRVING, TEXAS 75038

MR. MICHAEL BURCH

T. 469.242.4707

207 WEST MAIN STREET

MESQUITE, TX 75149

MR. ROGER L. STEPHENS, AIA

T. 214.505.0659

CAMPOS ENGINEERING

ENAPAY, LLC

HILL INTERNATIONAL

PROJECT NUMBER:

BUILDING NUMBER:

EA:CLIENT:

207 WEST MAIN STREET

MESQUITE, TX 75149

T. 214.607.0247

WWW.ENAPAYLLC.COM

MECHANICAL FLOOR PLAN DESIGN PRIMARY POWER

SECONDARY SIDE

5001 N. PIEDRAS / EL PASO, TEXAS 79930

VA EL PASO

5001 N. PIEDRAS

EL PASO, TEXAS 79930

MR. KEVIN ANGELES

756-16-110 EA03.0111

D

ES

IG

N

P R

IM

A

R Y

PO

W

ER

. S

EC

O

N D

A R

Y

SI

D E

IS

SU

E

FO

R C

O N

ST

R

U C

TI

O

N

PR

O

JE

C T

N U

M B

ER

: E

A

.0

M-2

F1

MECHANICAL PLAN

50'

SCALE

KEY NOTES

1. DISCONNECT EXISTING YORK CONDENSING UNIT AND RELOCATE TO

ROOF AS SHOWN. COORDINATE WITH ELECTRICAL. REPAIR EXISTING

CONDENSATE AND OVERFLOW DRAIN LINES.

2. RELOCATED YORK CONDENSING UNIT.

3. 4" SCH. 80 PVC DRAIN ROUTED OVER TO SUMP PUMP. ROUTE PIPING

BELOW ELECTRICAL DUCT BANK.

4. SUMP PUMP; LITTLE GIANT 6EC-CIA-RF, 1/3HP, 115 VAC OR EQUIVALENT.

5. 2" DISCHARGE CUT OFF ABOVE GRADE IN SIDE WALL OF SIDE WALK CURB.

6. 2" VENT UP ALONG EDGE OF VERTICAL RISE TERMINATE WITH

GOOSENECK. ANCHOR WITH TWO HOLE STRAPS.

B1

PIPING SUPPORT DETAIL

NO SCALE

D1

ROOF PENETRATION DETAIL

NO SCALE

ANCHOR EQUIPMENT TO ROOF

CURB WITH 3/8" STAINLESS

BOLTS W/WASHERS @ 2'-0"

MAX. SPACING, MINIMUM 3

PER SIDE.

#14 S/M STAINLESS SCREWS

@ 1'-0" SPACING MINIMUM

THREE PER SIDE.

1/4" BOLT WITH

WASHERS AND

NUT @ 2'-0"

SPACING MAXIMUM

ONE EVERY

CORNER MINIMUM.

PREFABRICATED

METAL SUPPORT.

(SEE CONDENSING

UNTI SUPPORT

DETAIL.)

F1

ROOF CONDENSING UNIT

ANCHOR DETAIL

NO SCALE

UGE

U G

E U

G E

E U

EUEU

E U

E U

T

S

U G

E

E U

S

S

S S S S S

3 5

B3

PIPING SUPPORT DETAIL

NO SCALE

S

S

S

S

S

SS S

V

V

V

V

V

PUMP

2" DISHARGE IN

CURB WALL

2" VENT ROUTED UP WALL

AND TERMINATED WITH

GOOSENECK WITH

INSECT SCREEN

4" DRAIN IN DUCT BANK

PULL BOX. PROVIDE

WITH 1/4"X1/4" SCREEN

4" DRAIN IN DUCT BANK

PULL BOX. PROVIDE

WITH 1/4"X1/4" SCREEN

SUMP PIT. SEE DETAIL

D3

SUMP ISOMETRIC

NO SCALE

7 7

March 31, 2021

2021-03-31 fcrabtree Text Box

SIMILAR TO ROOF PRODUCTS, INC, MODEL RPES-3

fcrabtree Cloud fcrabtree Text Box fcrabtree Text Box 4" PERFORATED DRAIN ROUTED OVER TO SUMP PUMP. ROUTE PIPING BELOW ELECTRICAL DUCT BANK.

fcrabtree Cloud fcrabtree Text Box fcrabtree Text Box 2021-11-18 fcrabtree Text Box fcrabtree Text Box

ADDENDUM 1

fcrabtree Text Box 2021-11-19 fcrabtree

COVER SHEET
E-0
E-1
E-2
E-3
[4] FA-101-2 FIRE ALARM - BUILDING 1 SECOND FLOOR PLAN
M-1
FA-101-2 FIRE ALARM - BUILDING 1 SECOND FLOOR PLAN
M-2
FA-101-2 FIRE ALARM - BUILDING 1 SECOND FLOOR PLAN

File details come from the government source that posted it. Updated .