36C25519R0103-004.pdf

PDF 17 MB Posted

Attached to
Relocate Step Down Unit P/N: 589-402 Federal contract opportunity
Solicitation number
36C25519R0103
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15

About this file

36C25519R0103 PO9-Final Drawings_Part1.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Relocate Step Down Unit P/N: 589-402, newest first.
File Type Posted
36C25519R0103-0003000.docx DOCX document
36C25519R0103-0003000.docx DOCX document
36C25519R0103-0002002.pdf PDF
36C25519R0103-0002005.pdf PDF
36C25519R0103-0002006.pdf PDF
36C25519R0103-0002004.pdf PDF
36C25519R0103-0002000.docx DOCX document
36C25519R0103-0002001.pdf PDF
36C25519R0103-0002003.pdf PDF
36C25519R0103-0002001.pdf PDF
36C25519R0103-0002002.pdf PDF
36C25519R0103-0002005.pdf PDF
36C25519R0103-0002004.pdf PDF
36C25519R0103-0002003.pdf PDF
36C25519R0103-0002000.docx DOCX document
36C25519R0103-0002006.pdf PDF
36C25519R0103-0001001.pdf PDF
36C25519R0103-0001000.docx DOCX document
36C25519R0103-0001003.pdf PDF
36C25519R0103-0001002.pdf PDF
36C25519R0103-0001000.docx DOCX document
36C25519R0103-0001001.pdf PDF
36C25519R0103-0001002.pdf PDF
36C25519R0103-0001003.pdf PDF
36C25519R0103-008.pdf PDF
36C25519R0103-006.pdf PDF
36C25519R0103-007.pdf PDF
36C25519R0103-004.pdf PDF
36C25519R0103-003.pdf PDF
36C25519R0103-009.pdf PDF
36C25519R0103-001.docx DOCX document
36C25519R0103-002.pdf PDF
36C25519R0103-005.pdf PDF
36C25519R0103-006.pdf PDF
36C25519R0103-005.pdf PDF
36C25519R0103-009.pdf PDF
36C25519R0103-003.pdf PDF
36C25519R0103-007.pdf PDF
36C25519R0103-002.pdf PDF
36C25519R0103-001.docx DOCX document
36C25519R0103-008.pdf PDF
36C25519R0103-000.docx DOCX document
36C25519R0103-000.docx DOCX document
Show all 43

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABBREVIATIONS

PROJ(D)

PLBG

PLYWD

PREFIN

RAD(R)

RESIL

REINF

REQ'D

SECT

SHWR

SPECS

REFRIG

GALVANIZEDGALVBMRK BENCHMARK

CONCRETE

MASONRY UNIT

CEILINGCLG

CLR

CMU

COL

CLO

CLEAR/CLEARANCE

COLUMN

CLOSET

CAB

CJ

CC

CB

BW

CL

BOC

BRZ

BRK

BO

BRG

BUR

BTM

BS

BUILT-UP ROOF

CENTER TO CENTER

CHALKBOARD

BOTTOM OF WALL

CENTER LINE

CONTROL JOINT/

CONSTRUCTION JOINT

CABINET

BACK OF CURB

BOTH SIDES

BOTTOM OF

BRONZE

BRICK

BEARING

BOTTOM

FOUNDATION

FLOOR DRAIN

FIRE EXTINGUISHER

FIRE

EXTINGUISHER

CABINET

FE

FEC

FDN

FD

EAST

EACH

EQUIPMENT

EXPOSED

EACH WAY

EXISTING

ELECTRICAL

EXTERIOR INSULATION

FINISH SYSTEM

ELEVATION/ELEVATOR

EXPANSION JOINT

EXISTING GRADE

ELECTRICAL CONTRACTOR

EXTERIOR

ETHYLENE PROPYLENE

DIENE TERPOLYMER

ELEV

EQUIP

EW

EPDM

EXP

EXIST

EXT

E

EA

EC

EG

EIFS

EJ

ELEC

INSULATION

INTERIOR

INSIDE DIAMETER

INSUL

IN(")

INT

ID

INCH

GRAB BAR

GENERAL CONTRACTOR

GYPSUM

GLASS/GLAZING

HOLLOW METAL

HIGH PRESSURE

DECORATIVE LAMINATE

HORIZONTAL

HARDWARE

HARDWOOD

HOSE BIB

HOT WATER

HEATING, VENTILATING

& AIR CONDITIONING

HDWR

HM

HORZ

HT

HPDL

HVAC

HW

HEIGHT

GB

GL

GRD

GYP

GC

HDWD

HB

GRADE

PART

PLAS

OVHD

PARTITION

PLASTER

OVERHEAD

SRT

SS

SQ

MISCELANEOUS

MASONRY OPENING

NOT IN CONTRACT

NOT APPLICABLE

OUTSIDE DIAMETER

NUMBERNO(#)

NTS

OC

OA

NOM

OFF

OPNG

OD

ON CENTER

OVERALL

NOMINAL

NOT TO SCALE

OFFICE

OPENING

MISC

N

MO

MULL

MTL

NIC

NA

NORTH

MULLION

METAL

SHT

SF

SB

SND

SIM

S

RM

ROW

RO

SAT

SAN

ARCHITECT/

ARCHITECTURAL

AB ANCHOR BOLT

APPROX

BLDG

BD

ARCH

BM

BLK

ADJ

AFF

AC

ACCU

ALUM

ANOD

ALT

APPROXIMATE

BLOCK/BLOCKING

AT

BOARD

BEAM

BUILDING

AIR COOLED

CONDENSING UNIT

ABOVE FINISHED FLOOR

ADJUSTABLE

ALTERNATE

ANODIZED

ACOUSTICAL

ALUMINUM

A/C AIR CONDITIONING

PLUS OR MINUS

CONSTRUCTIONCONST

COURSE

CERAMIC TILE

CONTINUOUS

CARPET

CORRIDOR

DIAMETER

DOOR

DOWN

DITTO

DIMENSION

DOUBLE

DRINKING FOUNTAIN

DETAIL

DRAWING

DOWNSPOUT

DIA

DR

DS

DN

DO

DIM

DTL

DWG

CRS

CT

CONT

CORR

CPT

DBL

DF

CONFERENCE

CONCRETE

CONF

CONC

FINISHFIN

FLUORESENT

FLOW LINE

FOLDING

FIELD VERIFY

FURNACE

FOOTING

FIRE RETARDANT

FOOT SCRAPER

FIBERGLASS

REINFORCED PLASTIC

FV

FT(')

FURR

FURN

FTG

G

GA

FOOT

FURRING

GAS

GUAGE

FRP

FLR

FLDG

FL

FRT

FS

FLUOR

FLOOR

FINISH GRADE

FINISH FLOOR

FG

FF

JOISTJST

LOW VOLUMN CHANGE

MASONRYMAS

MANUF

MATL

MAX

MECH

MEMB

MH

MIN

MIRR

MANUFACTURER

MATERIAL

MECHANICAL

MEMBRANE

MAXIMUM

MINIMUM

MANHOLE

MIRROR

LDR

LF

LAV

LAM

LVC

LOCN

LINEAL FEET

LADDER

LAVATORY

LAMINATE

LOCATION

REF

R

RAG

RD

PT

PR

QT

PTD

JT

JAN JANITOR

JOINT

PL

UNDER CABINET LIGHTREQUIRED

PHYSICAL THERAPY

RESPIRATORY CARE

SURGICAL INTENSIVE CARE UNIT

STUDDED RUBBER TILE

STAINLESS STEEL

SQUARE

SPECIFICATIONS

YD

SUSPENDED

ACOUSTICAL TILE

SIMILAR

SANITARY NAPKIN

DISPENSER

SECTION

SHOWER

SHEET

SQUARE FEET

SPLASH BLOCK

RESILIENT

SOUTH

SANITARY

RIGHT OF WAY

ROUGH OPENING

ROOM

WD

WNDW

WH

WNSCT

WC

WT

WWF

WP

VCT

VWC

VEST

VERT

W

W/

W/O

YARD

WATERPROOFING

/WATERPROOF

WELDED WIRE FABRIC

WATER HEATER

WATER CLOSET

WINDOW

WOOD

WAINSCOT

WEIGHT

VINYL COMPOSITION TILE

VINYL WALL COVERING

VERTICAL

VESTIBULE

WEST

WITH

WITH OUT

RC

SICU

CENTRAL STERILE

LONG TERM CARE

INTENSIVE CARE UNIT

OCCUPATIONAL THERAPY

MAGNETIC RESONANCE IMAGING

POST ANESTHETIC CARE UNIT

MEDICAL INTENSIVE CARE UNIT

LABOR-DELIVERY-RECOVERY-POST PARTUM

OPERATING ROOM

FOR MEDICAL

FACILITIES ONLY

EMERGENCY ROOM

COMPUTED TOMOGRAPHY

STORPLUMBING

PROJECT/(PROJECTED)

REFER/REFERENCE

ROOF DRAIN

RADIUS

RETURN AIR GRILLE

REINFORCING

REFRIGERATOR

RISER

PRESSURE TREATED

PAINTED

QUARRY TILE

PLYWOOD

PREFINISHED

PAIR

TLT

TV

TW

TOC

TPH

TO

TYP

UCL

T&B

T

SUSP

STRUCT

TEL

TB

T&G

PLATE/PLASTIC/

PROPERTY LINE STL

STD

STORAGE

TOILET PAPER HOLDER

TOP OF CURB

TOILET

TELEVISION

TOP OF

TYPICAL

TOP OF WALL

TONGUE & GROOVE

TOP & BOTTOM

STRUCTURE/STRUCTURAL

TREAD

TELEPHONE

TACKBOARD

SUSPENDED

ICU

OR

LDRP

MRI

MICU

LTC

PT

PACU

OT

CS

CT

ER

STEEL

STANDARD

DRAWING SYMBOLS

95.00

TOC

98.5

TOC

98.5 E

B

NEW ELEVATION

EXISTING ELEVATION

EXISTING CONTOUR

NEW CONTOUR

TEST BORING (SITE PLANS ONLY)

EXISTING ELEVATION

EXISTING ELEVATION

PROPERTY LINE

/1 A101

/1 A101 MATCHLINE

SHT. REFERENCE

ELEVATION DATUM

(SECTIONS, ELEVATIONS ONLY)

BUILDING SECTION

WALL SECTION

DETAIL DRAWING

AS-201

BUILDING ELEVATION

AI-201 INTERIOR ELEVATION

A100

WINDOW ID TAG

DOOR NUMBER

ROOM

NAME

ROOM NAME & NUMBER

PARTITION SYMBOL

1 REVISION TAG

COLUMN LINE GRID

ME100E EQUIPMENT NUMBER

? SITE PLAN NOTES

DEMOLITION PLAN NOTES

VICINITY MAP

NO SCALE

PRECAST CONCRETE

WALL PANEL TAG

XXX

AS-101

A-4 ALTERNATE TAG

PT-XX PAINT COLOR TAG

# PLAN NOTES &

ROOF PLAN NOTES

PROJECT

LOCATION

CUT STONE

STEEL

PLYWOOD

FINISH WOOD

CONT WD FRAMING

WOOD BLOCKING

MATERIAL SYMBOLS

LVC FILL

GRANULAR FILL

CONCRETE MASONRY

FACE BRICK

CONCRETE

EARTH

EXISTING CONSTRUCTION

ASPHALT

GLASS

RIGID OR TAPERED

INSULATION, EIFS

BATT INSULATION

GYPSUM BOARD

REFERENCE SECTION 010000 GENERAL REQUIREMENTS ITEM 1.3 STATEMENT OF BID ITEMS.

BID ITEM 1 (BASE BID) INCLUDES ALL SCOPE COMMUNICATED IN THE DRAWINGS AND SPECIFICATIONS.

BID ITEMS

BID ITEM 2 (DEDUCT): INCLUDES ALL WORK IN BID ITEM 1 WITH THE FOLLOWING EXCEPTIONS (ALL ITEMS BELOW TO BE BID AS ONE DEDUCT):

2A. OMIT ALL SCOPE OF WORK RELATED TO THE ROOF CLERESTORY LOCATED OVER PATIENT ROOMS #1 AND #2 (ROOMS C356 & C357). OMIT ALL STRUCTURAL REINFORCEMENT OF ROOF SLAB AND NEW CONSTRUCTION.

OMIT ALL FINISHES, FIXTURES, FURNISHINGS AND EQUIPMENT IN PATIENT ROOMS #1 AND #2 (ROOMS C356, C356A, C357, C357A). ALL FRAMING, DOORS AND WINDOWS AND MECHANICAL, ELECTRICAL AND PLUMBING ROUGH-IN TO

REMAIN FOR FUTURE BUILD-OUT.

2C. OMIT ALL FINISHES IN 3RD FLOOR QUIET ROOM (ROOM C339). ALL FRAMING, DOORS AND WINDOWS AND

MECHANICAL, ELECTRICAL AND PLUMBING ROUGH-IN TO REMAIN FOR FUTURE BUILD-OUT.

2D. OMIT ALL SCOPE OF WORK RELATED TO GREETER STATION (ROOM C326). OMIT ALL FRAMING, DOORS, MILLWORK

AND MECHANICAL, ELECTRICAL AND PLUMBING ASSOCIATED WITH GREETER STATION.

2E. OMIT ALL SCOPE OF WORK RELATED TO DEMOLITION, NEW WALLS, NEW DOORS AND NEW FINISHES IN BED

STORAGE AND ELEVATOR LOBBY (ROOMS D302, D301).

2F. OMIT ALL SCOPE OF WORK RELATED TO THE AUDIO/VISUAL EQUIPMENT IN THE MULTIPURPOSE/CHAPEL/ALTAR

(ROOMS D213A, D213B, D213C).

2B.

DOCUMENT SIGN-OFF SIGNATURE BLOCK

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

GI001

TITLE SHEET RELOCATE STEP DOWN UNIT

COLUMBIA, MO

4/11/2019

589-402

RELOCATE STEP DOWN UNIT

HARRY S. TRUMAN MEMORIAL VETERANS' HOSPITAL

DEPARTMENT OF VETERAN AFFAIRS

800 HOSPITAL DR, COLUMBIA, MO 65201

FINAL CONSTRUCTION DOCUMENTS

FINAL CONSTRUCTION DOCUMENTS

SHEET INDEX

PLUMBING

PP001 PLUMBING NOTES AND SYMBOLS

PD101 PLUMBING DEMOLITION PLAN - PARTIAL 2ND FLOOR

PD102 PLUMBING DEMOLITION PLAN - PARTIAL 3RD FLOOR

PL101 PLUMBING PLAN - PARTIAL 2ND FLOOR

PL102 PLUMBING PLAN - PARTIAL 3RD FLOOR

PL103 ENLARGED PLUMBING PLAN - PARTIAL 3RD FLOOR NORTH

PL104 ENLARGED PLUMBING PLAN - PARTIAL 3RD FLOOR SOUTH

PL104.2 ENLARGED PLUMBING PLAN - PARTIAL 3RD FLOOR SOUTH - BID ITEM #2 (DEDUCT)

PL201 MEDICAL GAS PLAN - PARTIAL 3RD FLOOR

PL301 PLUMBING RISERS

PL501 PLUMBING SCHEDULES AND DETAILS

MECHANICAL

MM001 MECHANICAL COVER SHEET

MM002 MECHANICAL COVER SHEET

MD101 HVAC DEMOLITION PLAN - 2ND FLOOR

MD102 HVAC DEMOLITION PLAN - 3RD FLOOR

MD102.2 HVAC DEMOLITION PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

MD103 HVAC DEMOLITION PLAN - ROOF

MD104 HYDRONICS DEMOLITION PLAN - 3RD FLOOR

MD104.2 HYDRONICS DEMOLITION PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

MH101 HVAC PLAN - 2ND FLOOR

MH101.2 HVAC PLAN - 2ND FLOOR - BID ITEM #2 (DEDUCT)

MH102 HVAC PLAN - 3RD FLOOR

MH102.2 HVAC PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

MH103 HVAC PLAN - ROOF PLAN

MH103.2 HVAC PLAN - ROOF PLAN - BID ITEM #2 (DEDUCT)

MP101 HYDRONICS PLAN - 2ND FLOOR

MP102 HYDRONICS PLAN - 3RD FLOOR

MP102.2 HYDRONICS PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

M-401 ENLARGED MECHANICAL PLANS

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-602 MECHANICAL SCHEDULES

M-603 MECHANICAL SCHEDULES

M-701 MECHANICAL CONTROL DETAILS

M-702 MECHANICAL CONTROL DETAILS

M-801 AIRFLOW DIAGRAM

ELECTRICAL

E-001 ELECTRICAL NOTES AND SYMBOLS

ED121 ELECTRICAL DEMOLTION PLAN - 2ND FLOOR

ED131 ELECTRICAL DEMOLITION PLAN - 3RD FLOOR

ED131.2 ELECTRICAL DEMOLITION PLAN -3RD FLOOR - BID ITEM #2 (DEDUCT)

ED141 ELECTRICAL DEMOLITION PLAN - ROOF

EL121 ELECTRICAL LIGHTING PLAN - 2ND FLOOR

EL131 ELECTRICAL LIGHTING PLAN - 3RD FLOOR

EL131.2 ELECTRICAL LIGHTING PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

EL132 ELECTRICAL ENLARGED LIGHTING PLANS

EL501 ELECTRICAL LIGHTING DETAILS AND SCHEDULES

EP101 ELECTRICAL POWER PLAN - BASEMENT

EP121 ELECTRICAL POWER PLAN - 2ND FLOOR

EP131 ELECTRICAL POWER PLAN - 3RD FLOOR

EP131.2 ELECTRICAL POWER PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

EP132 ELECTRICAL ENLARGED POWER PLANS

EP141 ELECTRICAL POWER PLAN - ROOF

EP501 ELECTRICAL POWER DETAILS

EP502 ELECTRICAL PARTIAL ONE-LINE DIAGRAM

EP601 ELECTRICAL POWER SCHEDULES

EP602 ELECTRICAL POWER SCHEDULES

ET131 ELECTRICAL TELECOMMUNICATIONS PLAN - 3RD FLOOR

ET131.2 ELECTRICAL TELECOMMUNICATIONS PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

ET501 ELECTRICAL TELECOMMUNICATIONS DETAILS AND SCHEDULES

ET502 ELECTRICAL TELECOMMUNICATIONS DETAILS

EY121 ELECTRICAL SYSTEMS PLAN - 2ND FLOOR

EY131 ELECTRICAL SYSTEMS PLAN - 3RD FLOOR

EY131.2 ELECTRICAL SYSTEMS PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

EY132 ELECTRICAL ENLARGED SYSTEMS PLAN

EY501 ELECTRICAL SYSTEMS DETAILS AND SCHEDULES

TA121 ELECTRICAL AUDIO VISUAL PLAN - 2ND FLOOR

TA501 ELECTRICAL AUDIO VISUAL DETAILS AND SCHEDULES

TA502 ELECTRICAL AUDIO VISUAL DETAILS AND SCHEDULES

SHEET INDEX

GENERAL

GI001 TITLE SHEET

GI002 ABA SHEET

GI003 LIFE SAFETY PLANS

GI104 PHASING PLAN - 2ND FLOOR

GI105 PHASING PLAN - 3RD FLOOR

HA101 HAZARDOUS MATERIAL PLANS

ARCHITECTURAL

AD101 DEMOLITION PLAN - 2ND FLOOR

AD102 DEMOLITION PLAN - 3RD FLOOR

AD102.2 DEMOLITION PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

AD103 DEMOLITION PLAN - 2ND FLOOR CEILING

AD104 DEMOLITION PLAN - 3RD FLOOR CEILING

AD104.2 DEMOLITION PLAN - 3RD FLOOR CEILING - BID ITEM #2 (DEDUCT)

AS101 FLOOR PLAN - 2ND FLOOR

AS102 FLOOR PLAN - 3RD FLOOR

AS102.2 FLOOR PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

AS103 FLOOR PLAN - DIMENSIONS - 2ND FLOOR

AS104 FLOOR PLAN - DIMENSIONS - 3RD FLOOR

AS104.2 FLOOR PLAN - DIMENSIONS - 3RD FLOOR - BID ITEM #2 (DEDUCT)

AS105 ENLARGED FLOOR PLANS

AS105.2 ENLARGED FLOOR PLANS - BID ITEM #2 (DEDUCT)

AS106 ROOF PLAN

AS106.2 ROOF PLAN - BID ITEM 2 (DEDUCT)

AS201 EXTERIOR ELEVATIONS

AS201.2 EXTERIOR ELEVATIONS - BID ITEM #2 (DEDUCT)

AS301 BUILDING SECTIONS

AS301.2 BUILDING SECTIONS - BID ITEM #2 (DEDUCT)

AS302 BUILDING SECTIONS

AS302.2 BUILDING SECTIONS - BID ITEM #2 (DEDUCT)

AS501 DOG HOUSE SECTIONS, WINDOWS & DETAILS

AS501.2 DOG HOUSE SECTIONS - BID ITEM #2 (DEDUCT)

AS502 DOG HOUSE WALL SECTIONS & DETAILS

AS601 DOOR INFORMATION

AS602 DOOR & WINDOW DETAILS

AS701 REFLECTED CEILING PLAN - 2ND FLOOR

AS702 REFLECTED CEILING PLAN - 3RD FLOOR

AS702.2 REFLECTED CEILING PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

AS703 CEILING & GENERAL DETAILS

ARCHITECTURAL INTERIORS

AI101 FINISH PLAN - 2ND AND 3RD FLOOR

AI101.2 FINISH PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

AI102 FINISH SCHEDULE - 2ND AND 3RD FLOOR

AI102.2 FINISH SCHEDULE - 3RD FLOOR - BID ITEM #2 (DEDUCT)

AI103 EQUIPMENT PLAN - 2ND AND 3RD FLOOR

AI103.2 EQUIPMENT PLAN - 2ND AND 3RD FLOOR - BID ITEM #2 (DEDUCT)

AI103.3 ENLARGED EQUIPMENT PLANS

AI104 EQUIPMENT SCHEDULE - 2ND AND 3RD FLOOR

AI104.2 EQUIPMENT SCHEDULE - 2ND AND 3RD FLOOR - BID ITEM #2 (DEDUCT)

AI105 WALL PROTECTION PLAN - 2ND AND 3RD FLOOR

AI105.2 WALL PROTECTION PLAN - 3RD FLOOR - BID ITEM #2 (DEDUCT)

AI106 SIGNAGE PLAN - 2ND AND 3RD FLOOR

AI106.2 SIGNAGE PLAN - 2ND AND 3RD FLOOR - BID ITEM #2 (DEDUCT)

AI201 INTERIOR ELEVATIONS

AI202 INTERIOR ELEVATIONS

AI203 INTERIOR ELEVATIONS

AI204 INTERIOR ELEVATIONS

AI205 INTERIOR ELEVATIONS

AI501 MILLWORK SECTION DETAILS

AI502 MILLWORK SECTION DETAILS

AI503 MILLWORK SECTION DETAILS

AI504 TILE DETAILS

STRUCTURAL

S-001 GENERAL NOTES

S-002 IBC INSPECTION TABLES

S-101 FRAMING PLAN - 3RD FLOOR

S-102 ROOF FRAMING PLAN

S102.2 ROOF FRAMING PLAN - BID ITEM #2

S-510 TYPICAL FRAMING DETAILS

S-511 FRAMING DETAILS

S-512 FRAMING DETAILS

S-513 LIGHT GAUGE FRAMING DETAILS

FIRE PROTECTION

FP101 FIRE PROTECTION HAZARD PLANS

FP101.2 FIRE PROTECTION HAZARD PLANS - BID ITEM #2 (DEDUCT)

C L

GENERAL REACH DIMENSIONS

MOUNTING HEIGHT DIMENSIONS

SOAP DISPENSER

MIRROR URINAL

TELEPHONE

CLOCK

LIGHT SWITCH

M A

X

M

A X

"6

M

A X

M

A X

M

A X

1'-2"

(TO HIGHEST

OPERABLE PART)

TOILET PAPER

DISPENSER

SANITARY NAPKIN

DISPOSAL

PAPER TOWEL

DISPENSER

OCCUPANCY SIGN

LATCH SIDE PREFERRED

THERMOSTAT

OR OTHER

CONTROL

48"

M

IN

Z

48"

Y

X 30" 24"

M

A X

30"

10" MAX

21" MAX

M

IN

M

A X

36" MIN

M

IN

M

A X

NOTE: X SHALL BE < 25";

Z SHALL BE > X, WHEN X < 20",

THEN Y SHALL BE 48" MAX

WHEN X IS 20"-25",

THEN Y SHALL BE 44" MAX.

NO SCALE

NO SCALE

M A

X

COUNTER OR

LAVATORY

T O

R A

IS

E

D L

T R

F

O R

R M

ELEVATION A ELEVATION B

PLAN: ROLL-IN TYPE ELEVATION: ROLL-IN

ACCESSIBLE SHOWER

T O

C O

N T

R O

L S

18"

1'-6"

2'-9"

T O

C O

N T

R O

L S

T

O

M A

X

FLEXIBLE SHOWER

HEAD EXTENSION

SHOWER UNIT W/

ACCESSIBLE CONTROLS

T

O

GRAB BAR

4'-0"

M

A X

16" MAX

23" MAX

F U

L L D

E P

T H

O F

S T

A L L

O R

48" MIN

M

IN

CLEAR FLOOR SPACE

1/2" MAX TRANSITION

NO SCALE

GRAB BAR

ELEV A

SEAT

SEAT

60" MIN

M

IN

M

IN

CLEAR FLOOR SPACE

27" MAX

GRAB BAR

1/2 " MAX TRANSITION

T

O

16"-27"

T O

C O

N T

R O

L S

GRAB BAR

SHOWER UNIT W/

ACCESSIBLE CONTROLS

& FLEX SHOWER HEAD

SHOWER UNIT W/

ACCESSIBLE CONTROLS

& FLEX SHOWER HEAD

SHOWER UNIT W/

ACCESSIBLE CONTROLS

& FLEX SHOWER HEAD

FOLDING SEAT

(OPTIONAL)

FOLDING SEAT

(0PTIONAL)

E L

E V

B

PLAN: TRANSFER TYPE

LAVATORY DIMENSIONS

17" MIN

M

IN

M

A X

M

A X

M

IN

6" MAX

8" MIN

NO SCALE

FRONT APPROACHSIDE APPROACH

DRINKING FOUNTAINS

17" MIN.

19" MAX.

48" MIN.

M

IN

NOT TO EXCEED

FOUNTAIN DEPTH

30" MIN.

M

IN

TO BUBBLER

M

IN

M

A X

HIGH

FOUNTAIN

LOW

FOUNTAIN

17-19"

6" MAX

8" MIN

M

IN

M

A X

M

IN

L O

W F

O U

N T

A

IN

NO SCALE

CL

CL

H.C. LAVATORYH.C. URINAL

H.C. FLOOR MTD. TOILET H.C. WALL MTD. TOILET

LAV FLOOR SPACE

BATHROOM FIXTURES & ACCESSORIES

16"-18"

36" MIN

M

A X

-1

7-9"

SANITARY NAPKIN DISPOSAL

TOILET PAPER DISPENSER

24"-42"6" MAX

12" MAX

-1

7"-9"

12" MAX

24"-42"

42" MIN

TOILET PAPER DISPENSER

SANITARY NAPKIN DISPOSAL

-3

36" MIN 6" MAX

M

A X

M

IN

M

IN

1'-7"

MIN

8" MIN6" MAX

CLEARANCE PROFILE

INSULATE DRAIN

& SUPPLY LINES 4

M A

X T

O

V

IE

W A

B L

E S

U R

F A

C E

MIRROR

PAPER TOWEL DISPENSER

"SOAP DISPENSER 3

M

IN

19" MAX

48" MIN

17"

MIN

"12"

MIN

16"-18"

54" MIN

42" MIN

NO SCALE

M

A X

13 1/2" MIN

M

A X

TO FLUSH CONTROL

-1

18" MIN GRAB BAR PER

ANSI A117.1-2009

39"-41"

18" MIN GRAB BAR PER

ANSI A117.1-2009

CL

ACCESSIBLE

SINGLE TOILET

16"-18"

LAVATORY

60" MIN

NO SCALE

M

IN

MEDICAL EQUIPMENT MOUNTING HEIGHTS

MEDICAL GAS

ZONE VALVE

NURSE CALL -

PATIENT TOILET

(DO NOT MOUNT

BEHIND TOILET)

CORD

ROBE HOOK

CALL STATION/

FLUSH-MOUNTED

STATION

RETURN AIR

REGISTER

O

R

FILM

ILLUMINATOR

RECEPTACLE

& GROUND

GROUND

FAULT

INDICATOR

REMOTE

GROUND

INDICATOR

VARIABLE

INTENSITY O.R.

LIGHT CONTROL

NITROGEN

SHUT-OFF

VALVE

O.R. RECEPTACLE

CODE BLUE

SWITCH

CLOCK

NO SCALE

SHARPS

CONTAINER

54" AFF TO

SLOT

WHEELCHAIR MANEUVERING

TURNING - PER VA GUIDELINES

CLEAR

2' - 6"

5' - 0"

1' - 0" 3' - 0"

1' - 0"

T-SHAPED

90 TURN 180 TURNS

60"

X < 48"

60"

48" 48"

60"

X < 48"

GENERAL NOTES

1. ALL CONSTRUCTION & RENOVATION SHALL MEET THE ARCHITECTURAL BARRIERS ACT

ACCESSIBILITY STANDARD (ABAAS).

2. SUPPLEMENTAL TO THE (ABAAS), CONSTRUCTION & RENOVATION IN HEALTH FACILITIES OF THE DEPARTMENT OF VETERAN AFFAIRS (VA) SHALL COMPLY WITH THE BARRIER FREE DESIGN GUIDE: A

SUPPLEMENT TO THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (PG-18-13).

5' - 6"

NO SCALE

NO SCALENO SCALE

MANEUVERING CLEARANCES AT DOORS

LATCH SIDE APPROACHLATCH SIDE APPROACH

HINGE SIDE APPROACH

HINGE SIDE APPROACH

FRONT APPROACHFRONT APPROACH

Y

M

IN

.X

24" MIN.

X

Y

Y

M

IN

X

24" MIN.

X

M

IN

M

IN

18" MIN.

24" PREF.

54" MIN.

Y

M

IN

NOTE: Y=48" MIN. IF DOOR

HAD BOTH A LATCH AND

CLOSER

PATIENT BEDROOM MIN. DOOR WIDTH: 3'-10"

NOTE: X=12" IF

DOOR HAS BOTH A

CLOSER AND LATCH

NOTE: X=36" MIN. IF Y=60",

X=42" MIN. IF Y=54"

NOTE: Y=48" MIN. IF

DOOR HAS CLOSER

NOTE: Y=54" MIN. IF

DOOR HAS CLOSER

PULL SIDE

PUSH SIDE

PULL SIDE PUSH SIDEPUSH SIDE

NO SCALE

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

GI002

ABA SHEET RELOCATE STEP DOWN UNIT

COLUMBIA, MO

4/11/2019

589-402

FINAL CONSTRUCTION DOCUMENTS

CODE INFORMATION

PROJECT INFORMATION:

1. CONSTRUCTION PURPOSE: RENOVATION

2. REASON FOR SUBMITTAL: RENOVATION

3. I CERTIFY THAT TO THE BEST OF OUR KNOWLEDGE THE

SUBMITTED PLANS FOR THE ABOVE-REFERENCED PROJECT

COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING:

2018 LIFE SAFETY CODE (NFPA-101)

2015 INTERNATIONAL BUILDING CODE (IBC)

2017 NATIONAL ELECTRICAL CODE (NFPA-70)

2015 INTERNATIONAL MECHANICAL CODE (IMC)

2015 INTERNATIONAL PLUMBING CODE (IPC)

2015 INTERNATIONAL FIRE CODE (IFC)

2010 ARCHITECTURAL BARRIERS ACT (ABA)

4. LOCATION OF ANY ANTICIPATED FUTURE ADDITIONS: UNKNOWN

5. OWNER:

HARRY S. TRUMAN MEMORIAL VETERANS' HOSPITAL

800 HOSPITAL DR.

COLUMBIA, MO 65201

PH (573) 814-6000

6. DATE DEVELOPED: SEE DATE ON TITLE BLOCK

7. DESIGN TEAM:

ARCHITECT:

M+HFG

142 N. MOSLEY ST., SUITE 300

WICHITA, KS 67202 316-262-2500

CONTACT: MARK CRANE

DESIGN CONSULTANTS:

PROFESSIONAL ENGINEERING CONSULTANTS

303 S. TOPEKA

WICHITA, KS 67202 316-262-2691

CONTACT:

CRISTY HELMICK (STRUCTURAL)

Cristy.Helmick@pec1.com

BRIAN HENRY (MECHANICAL)

Brian.Henry@pec1.com

JOSH WILCOX (ELECTRICAL)

Josh.Wilcox@pec1.com

JOY CARMICHAEL (PLUMBING)

Joy.MartinCarmichael@pec1.com

8. ARCHITECTS SEAL: SEE STAMP AT RIGHT

9. FIRE SERVICE: COLUMBIA, MISSOURI FIRE DEPT.

10. INSPECTION: VISN 15 SAFETY OFFICER

11. OCCUPANCY GROUP TYPE: I-2 (IBC), NEW HEALTH CARE (NFPA)

12. CONSTRUCTION TYPE: 2 (222) PER NFPA

13. STRUCTURAL CODE REQUIREMENTS

A. ALLOWABLE FLOOR AREA:

TOTAL ALLOWABLE FLOOR AREA: UNCHANGED

B. ALLOWABLE HEIGHT HEIGHT CALCULATIONS

NO HEIGHT MODIFICATIONS REQUIRED

C. FIRE-RESISTANCE RATING FOR BUILDING ELEMENTS: TYPE 2A

1. BEARING WALLS:

A. EXTERIOR: 1HR

B. INTERIOR: 1HR

2. NONBEARING WALLS:

A. EXTERIOR: 0HR, 1HR, SEE NFPA 101 TABLE 602

B. INTERIOR: 0HR

3. FLOOR CONSTRUCTION: 1HR

(INCLUDES SUPPORTING BEAMS & JOISTS)

4. ROOF CONSTRUCTION: 1HR

(INCLUDES SUPPORTING BEAMS & JOISTS)

5. SHAFT ENCLOSURES: 1HR, 2 HR, SEE NFPA 101 8.6, 18.3.1

D. MISCELLANEOUS REQUIREMENTS: (2015 IBC)

1. NFPA 101 18.3.2.1:

1 HR OCCUPANCY SEPARATION REQUIRED AT STORAGE ROOMS OVER 100 SF

(NEW HEALTH CARE OCCUPANCY)

14. ACTIVE FIRE SAFETY SYSTEMS

* NOTE:

ALL AREAS OF NEW & EXISTING CONSTRUCTION OF THIS PROJECT

WILL BE FULLY SPRINKLERED.

SPRINKLER SYSTEM SHALL COMPLY WITH NFPA

13 IN ALL AREAS

(a) SMOKE DETECTORS THROUGHOUT

(b) GENERATOR POWERED EMERGENCY LIGHTING

(c) GENERATOR POWERED EXIT LIGHTING

(d) PORTABLE EXTINGUISHERS

(e) AUTOMATIC AIR-HANDLING SHUT-DOWN

(f) FIRE ALARM SYSTEM

15. WATER SUPPLY: CITY OF COLUMBIA, MO

16. SEWAGE TREATMENT: CITY OF COLUMBIA, MO

17. HANDICAP PROVISIONS:

ACCESSIBLE ROUTE, TOILETS, LAVATORIES, SIGNAGE AND PARKING

SMOKE

COMPARTMENT #4

19,813 SF

SMOKE

COMPARTMENT #3

9,845 SF

SMOKE

COMPARTMENT #5

21,343 SF

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY NFPA 101-2018

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER2 HR

90 MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

2 HR

90 MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

2 HR

90 MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)1 HR

2 HR

60 MIN

90 MIN

HAZ./INCIDENTAL USE

FIRE BARRIER

1 HR 45 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS

(SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

SUBDIVIDING SPACES

SMOKE BARRIER (I-2 OCCUPANCY)

20 MIN

1/2

HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

NR

NR

SELF OR AUTO

CLOSING

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

NR

1 HR

VERT. OPG. (SHAFT)

FIRE BARRIER 60 MIN

[D]

1 HR

2 HR

60 MIN

90 MINEXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

(FIRE WALL IN IBC)

8.7

8.3

NFPA 6.1.14.4.1

18.1.3.5.1 19.1.3.5.1

NFPA 7.2.A.3.1 (1)

NFPA 18.1.3.8/

19.1.3.8 18.2.2.5/19.2.25 7.1.3.2.1

NFPA 19.3.1.1

NFPA 8.6.2

NFPA 18.3.2.1.2

NFPA 8.4.1.1

19.3.2.1

NFPA 8.4.2(3)

NFPA 8.5.2

NFPA 8.4.2

18.2.5.7.1.4 19.2.5.7.1.1

NFPA 8.4.2

18.3.6.2 19.3.6.2

21.3.6 39.3.6

NFPA 19.3.1.1

19.2.2.7

NFPA 7.2.6

NFPA 221

8.2.1.3

8.6.5

19.2.2.7 18.2.2.7

8.6.2 8.6.5(3) & 2

18.3.2.1.3 19.3.2.1.2

18.3.7.3 19.3.7.3

EXIST

SOL.

CORE WD.

NFPA 7.2.1.4.1

7.2.4.3.7 8.3.4 18.2.2.5.3,4,5,6,7 19.2.2.5,3,4

8.3.4.2 TBL

18.4.4.7.2.2 7.1.3.2.9(9)

NFPA 8.3.4.2 TBL

19.3.2.1.3,5

NFPA 8.3.4.2 TBL

8.5.4 18.3.7.8

NFPA 8.3.4.2 TBL

8.3.4.2 TBL

8.3.4.2 TBL

NFPA 8.3.4.2 TBL

8.3.4.2 8.4.3 19.3.2.1.4,3,5

8.4.3

8.4.3 18.3.6.4.1 19.3.6.4.1

N/A

FIRE

90 MIN

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR ONLY

FIRE

MIN

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLOWED

NFPA 90

8.3.5.7 9.2.1

NFPA 90

8.3.5.7 9.2.1

NFPA 8.3.5.7

9.2.1 7.2.4.3.5

N/A

8.5.5.2 18.3.7.3(2) 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4.1 8.4.6.2

8.4.4.1 8.4.6.2

8.4.4.1 8.4.6.2 18.3.6.4.1

N/A

RATED UL

ASSEMBLIES

UL 412

UL 419

UL 412

UL 419

UL 412

UL 419

UL 412

UL 419

UL415 (B)

UL 412

UL 419

UL 412

UL 419

UL 412

UL 419

UL 415 (A)

UL 412

UL 419

UL415 (B)

FE

PATIENT RM

#7

C364

PATIENT RM

#10

C350

PAT. TLT.

C363A

PAT. TLT.

C364A

PAT. TLT.

C365A

STAIR #7

C330

PATIENT RM

#6

C363

PATIENT RM

#5

C362

PAT. TLT.

C350A

PATIENT RM

#4

C361

PAT. TLT.

C349A

PATIENT RM

#2

C357

PAT. TLT.

C357A

PAT. TLT.

C356A

NOURISH.

C354

CORR

C3C6

CLEAN

UTILITY

ROOM

C333

SOILED

WORKROOM

C343

SHOWER

C338

STERILE

STORAGE

C347

CHART ROOM

C353

NURSE

STATION

C355

MEDS.

C352

STOR.

C359

CORR

C3C5

NURSE

STATION

C332

HSKPG.

C341

PAT. TLT.

C360A

CORR

C3C4

STAFF

TOILET

C336

EQUIP.

STORAGE

C345

PATIENT RM

#8

C365

PATIENT RM

#9

C351

PATIENT RM

#11

C349

BARIATRIC

PATIENT RM

#3

C360

STAFF

LOCKERS

C335

SWAMP

C321

CONSULT.

C322

MSA

C325

CORR.

C3C9

OFFICE

NURSE

MNGR.

C346

PATIENT RM

#1

C356

CORR

C3C2

QUIET ROOM

C339

MOBILE

X-RAY

ALCOVE

D301C

W.C. /

STRETCHER

ALCOVE

D301B

CORR

C3C3

ELEVATOR

LOBBY

D301

BED

STORAGE

D302

SOILED

D301A

GREETER

C326

STORAGE

C358

STAFF

LOUNGE

C334

EQUIPMENT

STORAGE

C327

BARIATRIC

ISOLATION

ROOM #14

C328

PAT. TLT.

C328A

ISOLATION

PATIENT

ROOM #13

C337

PATIENT RM

#12

C348

PAT. TLT.

C348A

FAMILY

TOILET

C324

F

E

FE

FE

MECH

C358A 17

34/2

3.4"

46.5"

105/3

10"

46.5"

105/3

10"

46.5"

ELEC.

C340

COMPLIANCE NOTE:

STORAGE OVER 100 SQ.FT.

REQUIRES 1 HR RATING.

INFILLED FLOOR CREATES

THIS AS A ROOM ON THIRD

LEVEL ONLY..

PAT. TLT.

C337A

PAT. TLT.

C362A

PAT. TLT.

C361A

PAT. TLT.

C351A

ANTE RM.

C329

OIT

C358C

STAIR #6

D320

PIV BADGE

ISSUANCE

(EXTG)

D321

H.R. SPEC.

ST. & RCMT.

(EXTG)

D322

H.R. SPEC.

RETIREMENT

BENEFITS

(EXTG)

D323

HALL

C3D3

H.R. SPEC.

ST. & RCMT.

(EXTG)

D324

SUPV. H.R.

SPEC. (EXTG)

D325

H.R. SPEC.

OWCP/

LEAVE/

AWARDS

(EXTG)

D326

CHIEF OF

H.R. (EXTG)

D327

HALL (EXTG)

C3D3

H.R. INTER

D316A

COPY RM

(EXTG)

D316

H.R. SPEC.

STF & RCMT.

(EXTG)

D316C

EQUIP.

(EXTG)

D352

SUPV. HR

SPEC.

D328

H.R. SPEC.

EMPLOYEE/

LABOR

RELATIONS

(EXTG)

D329

H.R. (EXTG)

D330

CORR. (EXTG)

C3D4

ELEC (EXTG)

D331C

VEND EQUIP

(EXTG)

D331B

STAIR 2

D331

ELEV #6

VOL.SVC

PROG.COORD.

(EXTG)

D332D

VOL. SVC.

WK. (EXTG)

D332ASTG. (EXTG)

D332B

SOCIAL WK.

(EXTG)

D333

SOCIAL WK.

(EXTG)

D333A

WK. RM.

(EXTG)

D333B

PATIO VEST.

(EXTG)

D334 TLT. (EXTG)

D334A

ELEV #1

ELEV #2

ELEV #3

WAITING

B347

FAMILY TLT

B320

CONFERENCE

B300

PATIENT RM

B301

1HR SB SEPARATION IS

MOVED DURING

CONSTRUCTION. MAKE

ANY CHANGES TO SMOKE

DETECTION AND ALARM.

95'

90'

29'

95'

105/3

10"

46.5"

DNDN

PROJECT

AREA

SYMBOLS

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

OCC. LOAD

FACTOR

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

FACP

FSA

FAA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

ACTUAL EXIT

WIDTH

NO. OF OCC./

NO. OF EXITS

1:50

10/1

2"

34"

FEC

FP

PROPERTY LINE

STARTING

LOCATION

TRAVEL DISTANCE

TRAVEL PATH

FE

FIRE EXTINGUISHER CABINET

FIRE PULL STATION

FIRE EXTINGUISHER

NOTES

[A] DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS OF SMOKE

BARRIERS WHERE HVAC SYSTEMS ARE FULLY DUCTED (18.3.7.3x2)

[B] AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL HAVE

DAMPERS (NFPA 8.2.4.4.3) (IBC 710.7)

[C] SMOKE DAMPERS ARE NOT REQUIRED WHERE OPENINGS IN DUCT

ARE LIMITED TO A SINGLE SMOKE COMPARTMENT & DUCTS ARE

MADE OF STEEL (IBC 716.5.5)

[D] TRANSFER GRILLES REGARDLESS OF WHETHER THEY ARE

PROTECTED ARE NOT ALLOWED IN THESE DOORS OR WALLS

(NFPA 18.3.6.4)

XX

PROJECT AREA

MULTI-PURPOSE

D213A

STORAGE

D213D

CHAPEL

D213B

ALTAR

D213C

STORAGE

D213E

STORAGE

D213G

COMPLIANCE NOTE:

MULTIPURPOSE & CHAPELS

SERVING OVER 50

OCCUPANTS PROVIDED IN

CONNECTION WITH HEALTH

CARE SHALL HAVE MEANS

OF EGRESS PER ASSEMBLY

OCCUPANCY. WHEN

OPERABLE PARTITION IS NOT

DIVIDING SPACE,

OCCUPANCY IS OVER 50.

776/8

18.6"

46.5"

776/8

31.8"

40.5"

670/8

14"

46.5"

CHAPLAIN

SERVICES

D213F

STORAGE

D213J

STORAGE

D213K

A/V CLOSET

D213I

ELEC / TELE /

MECH (EXTG)

D217

SERVERS

(EXTG)

D216

CORR (EXTG)

C2D4

OI&T (EXTG)

D209

INFO MGT.

SVC (EXTG)

D208

CORR (EXTG)

C2C3

SOCIAL

WORKER

(EXTG)

C243

PSY (EXTG)

C241

PSY (EXTG)

C239

BH SECTY

(EXTG)

C237

MHC

RN(EXTG)

C237A

HEALTH INFO

MGT (EXTG)

D218 CHIEF

HEALTH INFO

MGT (EXTG)

D218C

INFO MGT.

SVC (EXTG)

D218B

CLINICAL

DOC SPEC

(EXTG)

D218A

CHAPLAIN

HALL

D218D

STAIR #6

D216D

ELEV 6

SOCIAL

WORKER

(EXTG)

D205C

VOCATIONAL

REHAB. ASST.

(EXTG)

D205B

GROUP RM

(EXTG)

D205

CORR.

(EXTG)

TLT (EXTG)

D215

TLT (EXTG)

D214

TLT (EXTG)

D210

PROCEDURE

RM (EXTG)

D219E

PHYSICAN

OFFICE/EXAM

(EXTG)

D219F

EXAM (EXTG)

D219B

STAIR #2

D207

OFFICE

(EXTG)

D204

OFFICE

(EXTG)

D203

OFFICE

(EXTG)

D219C

PM&R PAIN

CLINIC

(EXTG)

D219

HALL

D219A

TLT

D219D

PSYCH

(EXTG)

D212D

HUD/ VASH

COORD.

(EXTG)

D212A

SOCIAL

WORKER

(EXTG)

D212B

SOCIAL

WORKER

(EXTG)

D212E

SOCIAL

WORKER

(EXTG)

D212F

SOCIAL

WORKER

(EXTG)

D212C

MECH RM.

(EXTG)

C221

SOCIAL

WORKER

(EXTG)

C242

PSY. (EXTG)

C253

OFFICE

(EXTG)

C240

PSY. (EXTG)

C254

PSY. (EXTG)

C255

PSY. (EXTG)

C238

N.

PRACTITIONER

(EXTG)

C236

SUICIDE

PREV.

SOCIAL WK.

(EXTG)

C256

SUICIDE

PREV.

COORD.

(EXTG)

C257

CLINICAL N.

SPEC. (EXTG)

C235

DIR B.H.

(EXTG)

D235B

OPS MGR

(EXTG)

D235A

CLINICAL N.

SPEC. (EXTG)

D234

PSY LAB

(EXTG)

D233

PSYCH

(EXTG)

C232

PSY (EXTG)

C231

PSY (EXTG)

C251

OFFICE

(EXTG)

C252

PSY. (EXTG)

C227C

PSYCH.

INTERNS

(EXTG)

C250

STG (EXTG)

C249E

OFFICE

(EXTG)

C227B

WOMEN'S TLT

C229

MENS TLT.

C230

STAIR #7

(EXTG)

C228

PSYCH LAB

(EXTG)

C226A

PSYCH. LAB

(EXTG)

C226

PSY (EXTG)

C249C

PROG.

SUPPORT

CLERK

(EXTG)

C249D

OFFICE

(EXTG)

C227A

PSYCH.

INTERNS

(EXTG)

C247

PROG.

SUPPORT

(EXTG)

C246

CUSTOMER

ASST. (EXTG)

C249A

INTERVIEW

RM (EXTG)

C249B

COPY RM

C248

BH CLINICAL

MGR (EXTG)

C225

PSYCH

(EXTG)

C224

PSYCH

(EXTG)

C223

PSYCHOSOCIAL

REHAB.

SUPV. (EXTG)

C222

CORR.

(EXTG)

CORR. (EXTG)

C2C3

CORR. (EXTG)

C2D3

CORR

(EXTG)

CORR. (EXTG)

C2D2

VOCATIONAL

REHAB. ASST.

(EXTG)

D212

SOCIAL

WORKER

(EXTG)

D206

CLOSET

(EXTG)

D205A

CORR. (EXTG)

C2D1

SUPPORTIVE

EMPLOYMENT

SPEC. (EXTG)

C202

MARRIAGE &

FAM. THER.

(EXTG)

C201F

B.H. CARE

COORD.

(EXTG)

C201E

LEAD PROG.

SUPPORT

(EXTG)

C201A

B.H. CLINIC N.

(EXTG)

D201B

PROG.

SUPPORT

(EXTG)

C201C

DINING/

M.P.R. (EXTG)

C201

SOILED

DISPATCH

(EXTG)

D201A

ELEV. LOBBY

D201

CLEAN UTIL.

(EXTG)

D202

ELEV #4

ELEV #5

ELEV #7

ELEV #8

95'

91'

SMOKE

COMPARTMENT #4

20,224 SF

SMOKE

COMPARTMENT #1

16,620 SF

SMOKE

COMPARTMENT #2

12,350 SF2

S.C. 1 SUITE 1 (NON-PATIENT

CARE) - 1,289 SF

S.C. 4 SUITE 2 (NON-PATIENT

CARE) - 1,346 SF

S.C. 4 SUITE 1 (NON-PATIENT

CARE) - 516 SF

S.C. 5 SUITE 1 (NON-PATIENT

CARE) - 3,436 SF

S.C. 2 SUITE 1 (NON-PATIENT

CARE) - 622 SF

S.C. 4 SUITE 1 (NON-PATIENT

CARE) - 437 SF

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

GI003

LIFE SAFETY PLANS RELOCATE STEP DOWN UNIT

COLUMBIA, MO

4/11/2019

589-402

FINAL CONSTRUCTION DOCUMENTS

N 8' 16' 32'

1/16" = 1'-0"

0'

1/16" = 1'-0"

CODE PLAN - THIRD FLOOR

1" = 50'-0"

KEY PLAN - 3RD FLOOR

N

8' 16' 32'

1/16" = 1'-0"

0'

1" = 50'-0"

KEY PLAN - 2ND FLOOR

N

N

1/16" = 1'-0"

CODE PLAN - 2ND FLOOR

HEALTH CARE OCCUPANCY (NFPA CH. 18) NOTES

18.2.5.2

DEAD END CORRIDORS SHALL NOT EXCEED 30 FT.

18.2.5.3

COMMON PATH OF TRAVEL SHALL NOT EXCEED 100 FT.

18.2.6.2.1

TRAVEL DISTANCE BETWEEN ANY POINT IN A ROOM AND AN

EXIT SHALL NOT EXCEED 200 FT.

SHADED AREA

NOT IN SCOPE

OF PROJECT

S H

A D

E D

A R

A

N

T

I N

S C

O P

P R

O J E

C T

S H

A D

E D

A R

T

I N

S C

O

P R

O J E

C T

PHASE 1.1

PHASE 1.1

PHASE 2

SHADED AREA

NOT IN SCOPE

OF PROJECT

MECHANICAL ROOM

DUCTWORK TO BE

REMOVED FROM AHU 7/8

WHICH CURRENTLY

FEEDS FLOOR 3.

SEE MEP DRAWINGS.

PHASE 1.1 ABOVE CEILING:

PLUMBING AND MECHANICAL

WORK AS PER MEP DRAWINGS.

ANY WORK THAT DISRUPTS

NORMAL OPERATIONS IN THESE

AREAS SHALL BE COMPLETED

AFTER NORMAL BUSINESS HOURS.

ALL CEILINGS MUST BE

REINSTALLED DAILY TO MAINTAIN

SPRINKLER COVERAGE.

PHASE 2 INCLUDES

CONSTRUCTION OF NEW

STRUCTURAL SLAB AT THIRD LEVEL

AND THE REMODELING OF THE

AUDITORIUM SPACE ON SECOND

LEVEL.

STRUCTURAL WORK

ABOVE CEILING DURING

PHASE 2 TO SUPPORT

NEW AHU

PHASE 1.1 ABOVE CEILING:

PLUMBING AND MECHANICAL

WORK AS PER MEP DRAWINGS.

ANY WORK THAT DISRUPTS

NORMAL OPERATIONS IN THESE

AREAS SHALL BE COMPLETED

AFTER NORMAL BUSINESS HOURS.

ALL CEILINGS MUST BE

REINSTALLED DAILY TO MAINTAIN

SPRINKLER COVERAGE.

OUTER GYPSUM OF THIS EXISTING

WALL (CORRIDOR/OFFICE SIDE)

WILL NOT BE DEMOLISHED AND

WILL ACT AS THE TEMPORARY

BARRIER. CONFIRM EXISTING

WALL WILL MEET 1 HOUR BARRIER

OR MODIFY TO MEET FINAL

DESIGN OF 2 HOURS.

TEMP 1 HR CONSTRUCTION

BARRIERS DURING PHASE 2

TEMP CONSTRUCTION

BARRIERS DURING PHASE 2

TEMP 1 HR CONSTRUCTION

BARRIERS DURING PHASE 2

TEMP 1 HR CONSTRUCTION

BARRIERS DURING PHASE 2

M

II

N

C

L E

A R

M

IN

C

L E

A R

MIN. CLEAR

5' - 0"

MIN. CLEAR

5' - 0"

SCOPE OF WORK LEGEND

PHASE 1: THIRD FLOOR - DEMOLITION OF EXISTING AREA, DEMO OF

ROOF FOR NEW CLERESTORY, CONSTRUCTION OF NEW STEP DOWN

UNIT WITH ALL NEW MEP SYSTEMS AS NEEDED

PHASE 2: SECOND & THIRD FLOOR - DEMOLITION OF EXISTING

AUDITORIUM, CONSTRUCT NEW CONCRETE FLOOR AT THIRD LEVEL,

FINISH NEW CHAPEL/MULTIPURPOSE ON SECOND FLOOR.

PHASE 3: THIRD FLOOR - WORK IN EXISTING AREAS NOT VACATED

THAT NEED TO REMAIN OPERATIONAL. SPECIAL COORDINATION NEED

TO ACCOMPLISH WORK AFTER HOURS, NIGHTS AND WEEKENDS.

PHASE 1.1: SECOND FLOOR CEILING - SPECIAL COORDINATION OF

MEP WORK RELATED TO PHASE 1, SHALL BE ACCOMPLISHED AFTER

HOURS, NIGHTS & WEEKENDS

NOTES:

1. TEMPORARY CONSTRUCTION BARRIERS SHALL BE MIN. 1 HOUR RATED ASSEMBLY.

2. ALL CEILINGS DISTURBED DURING OVER CEILING WORK SHALL BE RE-INSTALLED PRIOR

TO END OF EACH WORK SHIFT.

3. ALL OPENINGS THROUGH CONCRETE FLOORS (RATED), MUST BE FIRSTOPPED OR

INFILLLED PRIOR TO END OF EACH WORK SHIFT.

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

GI104

PHASING PLAN - 2ND FLOOR RELOCATE STEP DOWN UNIT

COLUMBIA, MO

4/11/2019

589-402

FINAL CONSTRUCTION DOCUMENTS

1/8" = 1'-0"

PHASING PLAN - PARTIAL 2ND FLOOR

SHADED AREA

NOT IN SCOPE

OF PROJECT

S H

A D

E D

A R

T

I N

S C

O

P R

O J E

C T

FEC

FEC

FEC

EX

FEC

PHASE 1

PHASE 2

PHASE 3

SHADED AREA

NOT IN SCOPE

OF PROJECT

TEMP 1HR CONSTRUCTION

BARRIER DURING PHASE 1

TEMP 1 HR CONSTRUCTION

BARRIER DURING PHASE 1

EXISTING ELECTRICAL

CLOSET TO BE EXPANDED

DURING PHASE 1 WORK

WINDOW TO BE

REPLACED DURING

PHASE 1 WORK

LOUVRE TO BE REMOVED

AND REINSTALLED DURING

PHASE 2 WORK

DURING PHASE 2, OUTER

GYPSUM OF THIS EXISTING

WALL WILL NOT BE

DEMOLISHED AND WILL

ACT AS THE TEMPORARY

BARRIER. CONFIRM

EXISTING WALL WILL MEET

1 HOUR BARRIER OR

MODIFY TO MEET FINAL

DESIGN OF 1 HOURS.

OUTLINE OF CLERESTORY

STRUCTURE ABOVE TO BE

CONSTRUCTED DURING PHASE 1

-SEE STRUCTURAL

MECHANICAL ROOM MUST BE

CONSTRUCTED AND NEW AHU

INSTALLED PRIOR TO THE

OPERATION OF AREAS IN PHASE 1

TEMP 1 HR CONSTRUCTION

BARRIER DURING PHASE 1

PHASE 3 WORK REQUIRING

TIE IN TO EXISTING WORK

TO REMAIN.

PHASE 2 INCLUDES

CONSTRUCTION OF NEW

STRUCTURAL SLAB AT THIRD LEVEL

AND THE REMODELING OF THE

AUDITORIUM SPACE ON SECOND

LEVEL.

DOOR TO BE REPLACED

DURING PHASE 3.

M

IN

C

L E

A R

5'-0" MIN. CLEAR

THIS AREA MUST BE

OPERATIONAL PRIOR TO

START OF PHASE 3

SCOPE OF WORK LEGEND

PHASE 1: THIRD FLOOR - DEMOLITION OF EXISTING AREA, DEMO OF

ROOF FOR NEW CLERESTORY, CONSTRUCTION OF NEW STEP DOWN

UNIT WITH ALL NEW MEP SYSTEMS AS NEEDED

PHASE 2: SECOND & THIRD FLOOR - DEMOLITION OF EXISTING

AUDITORIUM, CONSTRUCT NEW CONCRETE FLOOR AT THIRD LEVEL,

FINISH NEW CHAPEL/MULTIPURPOSE ON SECOND FLOOR.

PHASE 3: THIRD FLOOR - WORK IN EXISTING AREAS NOT VACATED

THAT NEED TO REMAIN OPERATIONAL. SPECIAL COORDINATION NEED

TO ACCOMPLISH WORK AFTER HOURS, NIGHTS AND WEEKENDS.

PHASE 1.1: SECOND FLOOR CEILING - SPECIAL COORDINATION OF

MEP WORK RELATED TO PHASE 1, SHALL BE ACCOMPLISHED AFTER

HOURS, NIGHTS & WEEKENDS

NOTES:

1. TEMPORARY CONSTRUCTION BARRIERS SHALL BE MIN. 1 HOUR RATED ASSEMBLY.

2. ALL CEILINGS DISTURBED DURING OVER CEILING WORK SHALL BE RE-INSTALLED PRIOR

TO END OF EACH WORK SHIFT.

3. ALL OPENINGS THROUGH CONCRETE FLOORS (RATED), MUST BE FIRSTOPPED OR

INFILLLED PRIOR TO END OF EACH WORK SHIFT.

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

GI105

PHASING PLAN - 3RD FLOOR RELOCATE STEP DOWN UNIT

COLUMBIA, MO

4/11/2019

589-402

FINAL CONSTRUCTION DOCUMENTS

1/8" = 1'-0"

PHASING PLAN - PARTIAL 3RD FLOOR

REMOVE ALL ASBESTOS PIPE FITTING INSULATION WITHIN THE ASBESTOS ABATEMENT WORK SPACE, ABOVE AND BELOW CEILINGS AND IN THOSE CHASES SCHEDULED FOR DEMOLITION. REMOVE ALL DEBRIS FOUND IN THE WORK AREA. USE TRADITIONAL ASBESTOS ABATEMENT METHODS IN THOSE AREAS WHERE INSULATION MAY BE DAMAGED AND SIGNIFICANT PORTIONS OF DEBRIS MAY EXIST. CHASE WALLS SHALL BE REMOVED USING TRADITIONAL ASBESTOS ABATEMENT TO PRECLUDE ANY POSSIBLE RELEASE OF MATERIAL INTO THE

AREA DUE TO DEMOLITION ACTIVITIES.

A.

GENERAL HAZARDOUS MATERIALS NOTES:

REMOVE ALL FLOOR TILE AND FLOOR TILE MASTIC WITHIN THE ASBESTOS ABATEMENT WORK AREA.B.

REMOVE ALL WALL TILE AND WALL TILE MASTIC WITHIN THE ASBESTOS ABATEMENT WORK AREA.C.

REMOVE AND REPLACE WITH NEW ANY PLUMBING/MECHANICAL SYSTEM THAT IS TO REMAIN IN USE. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS. PLUMBING/MECHANICAL SYSTEMS TO BE PERMANENTLY REMOVED, MAY BE CUT AND WRAPPED AND REMOVED IN SECTIONS WITH THE INSULATION STILL ATTACHED.

D.

ENCAPSULATE THE EXPOSED ENDS OF ANY PIPE INSULATION THAT ARE NOT REMOVED AT ADJOINING FLOOR

LEVELS.

E.

SEE SPECIFICATIONS APPENDIX A - ASBESTOS SURVEY FOR MORE INFORMATION. SEE

SPECIFICATIONS SECTIONS 028211 & 028213-19 FOR ASBESTOS ABATEMENT.

F.

ASBESTOS CONTAINING

FLOORING MASTIC

DEMO LEGEND

ASBESTOS CONTAINING

PIPING WRAPS

2ND FLOOR: 0 S.F.

3RD FLOOR: 2850 S.F.

2ND FLOOR: 130 L.F.

3RD FLOOR: 306 L.F.

APPROXIMATE QUANTITIES

EaFGGaHJ

Ha

PLAN NOTES:

1. ALSO REFERENCE MEP DRAWINGS FOR SCOPE OF DEMOLITION.

2. CONTRACTOR TO PROTECT EXISTING STRUCTURE FROM DAMAGE. TYP. AT AREAS IN PROJECT SCOPE.

SHADED AREA

NOT IN SCOPE

OF PROJECT

SHADED AREA

NOT IN SCOPE

OF PROJECT

S H

A D

E D

A R

T

I N

S C

O

P R

O J E

C T

S H

A D

E D

A R

T

I N

S C

O

P R

O J E

C T

P

IP

IN

G

W R

A P

A P

P R

O X

L

.F

P

IP

IN

G

W R

A P

A P

P R

O X

L

.F

P

IP

IN

G

W R

A P

A P

P R

O X

L

.F

P

IP

IN

G

W R

A P

A P

P R

O X

L

.F

EaFGGaHJJbKLLaMNNa w 6.3

Ha

6.2

Ja

C330

SHADED AREA

NOT IN SCOPE

OF PROJECT

SHADED AREA

NOT IN SCOPE

OF PROJECT

S H

A D

E D

A R

T

I N

S C

O

P R

O J E

C T

PLAN NOTES:

1. ALSO REFERENCE MEP DRAWINGS FOR SCOPE OF DEMOLITION.

2. CONTRACTOR TO PROTECT EXISTING STRUCTURE FROM DAMAGE. TYP. AT AREAS IN PROJECT SCOPE.

FLOORING MASTIC

APPROX. 1490 S.F.

FLOORING MASTIC

APPROX. 360 S.F.

FLOORING MASTIC

APPROX. 630 S.F.

ROOM FINISHES MAY

CONTAIN ASBESTOS

FLOORING MASTIC

APPROX. 300 S.F.

P

IP

IN

G

W R

A P

A P

P R

O X

L

.F

P

IP

IN

G

W R

A P

A P

P R

O X

L

.F

PIPING WRAP

APPROX. 40 L.F.

PIPING WRAP

APPROX. 30 L.F.

FLOORING MASTIC

APPROX. 70 S.F.

P

IP

IN

G

W R

A P

A P

P R

O X

L

.F

C301D

C301C

C301A

C301B

C301E

C321EC321A

C321D

C321B

C324A

C324

C322D

C322B

C323

C3C2

D307B

D308

D307A

D307

D308B

D308A

C3D1

D306

D306A

D305

D308C

D301 D301A

D332C D332B

D332

D332A

D353A

D353

C101O

C3D4

D331C D331B

D352

D316C

D316

D316A D315

D314A

D314

D331

D304

C3B1

C342

C343

C343A

C326 C341

D309

C341A

C341E

C341C

C325C

C325D

C3C4 C327

C328

C329A C329B

C328A C334A

C334

C3C3

C337

C101N C333

C329

C330

C3C6

C331A

C331B C332A

C332 C335

C335A

C335B

C336A

C336 D310

D310B

D311A

D310A

D311 D312 D312A

D317

D319

D320

D318

D321

C3D3

D322

D323

D324

D325

D326

D327

C3D3

D328

C3D3

D329

D330

D332D

D333 D333A

D333B

D334

C331

OPEN

TO

BELOW

A300

A301A302

C300C300A

C302C303

D302

D213

C243

C241

C239

C237

C237A

D213A

D213B

D213C

D217

D216D

D218AD218BD218C

D218C235B

C2D4

D216

D209

D208

D210 D214 D215

D205C

D205B

D206B

C2D1

C2C3

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

HA101

HAZARDOUS MATERIAL PLANS RELOCATE STEP DOWN UNIT

COLUMBIA, MO

4/11/2019

589-402

FINAL CONSTRUCTION DOCUMENTS

1/8" = 1'-0"

HAZARDOUS PLAN - PARTIAL 2ND FLOOR

1/8" = 1'-0"

HAZARDOUS PLAN - PARTIAL 3RD FLOOR

PROJECT

LOCATION

CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.

THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE ARCHITECT OF ANY

CONDITIONS THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.

A.

GENERAL DEMOLITION NOTES:

PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY

DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

B.

VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE

DRAWINGS AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE

THE INTENDED WORK.

C.

ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS

RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL

WORK ASSOCIATED WITH THIS CONTRACT.

D.

CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH

SURROUNDING EXISTING FINISHES NOT DISTURBED.

E.

TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY

DEMOLITION NOTES ARE FOR GENERAL INFORMATION ONLY FROM INFORMATION

OBTAINED FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD

VERIFY MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS

BID.

F.

ALL APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION AND STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER. VA TO REMOVE ALL WALL

MOUNTED SYSTEMS FURNITURE AND FREE STANDING FURNITURE PRIOR TO

CONSTRUCTION

G.

MISCELLANEOUS FLOOR PENETRATIONS AND DEMO FOR NEW MECHANICAL AND

ELECTRICAL WORK SHALL BE COORDINATED FROM ARCHITECTURAL, MECHANICAL,

AND ELECTRICAL PLANS.

H.

REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DEMO PLANS FOR

DEMOLITION, SALVAGE AND RE-USE OF EXISTING ITEMS.

I.

PATCH FLOOR AT REMOVED WALLS AND CASEWORK, PREPARE FLOOR TO RECEIVE

NEW FLOORING AS REQUIRED.

J.

ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES TO RECEIVE

INFILL PER STRUCTURAL DETAIL.

K.

REMOVE ALL STAINLESS STEEL CORNER GUARDS CAREFULLY AND GIVE TO OWNER.L.

ELEMENTS INDICATED WITH A DASHED LINE ARE TO BE DEMOLISHED AND

DISPOSED OF AS A PART OF THIS PROJECT, UNLESS NOTED OTHERWISE.

M.

IN EXISTING AREAS, RENOVATION AND DEMOLITION WORK SHALL BE ACCOMPLISHED

WITH MINIMAL DISRUPTION TO OPERATIONS. IF REQUIRED, THE OWNER RESERVES THE

RIGHT TO TEMPORARILY STOP WORK OF SPECIFIC CONSTRUCTION OPERATIONS

SHOULD THE OWNER IDENTIFY AN EMERGENCY OR DANGER EXISTS TO THE WELFARE

OF THE OCCUPANTS ON ACCOUNT OF SUCH WORK OR OPERATIONS.

N.

CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER

NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.

O.

IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL

BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING

ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT ARE NOT

SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND CONTINUE ANY

SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.

P.

ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT ARE TO BE REMOVED SHALL BE

DISCONNECTED AT SOURCE AND REMOVED.

Q.

ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT

THAT ARE TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED

ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,

TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)

R.

ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR

DEMOLITION.

S.

REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO

BE DEMOLISHED. SEE MEP PIPING DRAWINGS.

T.

RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.U.

Ea

Ea

F

F

G

G

Ga

Ga

H

H

J

J

Jb

Jb

K

K

L

L

La

La

M

M

N

N

Na

Na w 6.3 w 6.3

Ha

Ha

6.26.2

Ja

Ja

SHADED AREA

NOT IN SCOPE

OF PROJECT

S H

A D

E D

A R

T

I N

S C

O

P R

O J E

C T

SHADED AREA NOT IN

SCOPE OF PROJECT

131313131313

2"

10' - 11 1/4" 10' - 6 3/4"

WALL DOOR

CEILING

AND GRID

DEMO LEGEND

FLOOR

PENETRATION

SCOPE OF WORK LEGEND

SHADED AREA NOT IN SCOPE OF WORK

DIAGONAL HATCH AREA INDICATES WORK IN EXISTING SPACES NOT VACATED

AND THAT NEED TO REMAIN OPERATIONAL. COORDINATION WITH COR IS

NEEDED TO ACCOMPLISH WORK AFTER HOURS, NIGHTS AND WEEKENDS.

D213

C243

C241

C239

C237

C237A

D213A

D213B

D213C

D216D

D218A

D218BD218C

D218C235B

C2D4

D208

D210 D214 D215

D205C

D205B

D206B

C2D1

C2C3

C235AC234C233

C2C2

C229

C232C231

C230

C228

C226A

C226

C225

C224

C223

C222

C221

C201

C201C

C201B

C201A

C201E C201F

C2D2

C235

C236

C238

C240

C242C253

C248

D212FD212C

C246

C247

C249A C249B

C249

C227A

C227BC227 C249E C250

C249CC249D

C251C252C227C C257

C256

C255

C254

C202

D202B

D202

D212

D201

D201A

D205A

D206

D206A

D212B

D212A D212D

D212E

D205

D207C D207B

D207

D204

D203

A200

A201A202

D219

D219B

D219C

D217

D216

D209

C3D3 C3D4

C2D3

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA 51101

712.252.4014

142 N. MOSLEY ST.

WICHITA, KANSAS 67202

316.262.2500

303 S. TOPEKA

WICHITA, KANSAS 67202

316.262.2691

AD101

DEMOLITION PLAN - 2ND FLOOR RELOCATE STEP DOWN UNIT

COLUMBIA, MO

4/11/2019

589-402

FINAL CONSTRUCTION DOCUMENTS

4' 8' 16'

1/8" = 1'-0"

0'

N

DEMO SCHEDULE

1 EXISTING WALL AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED (FULL HEIGHT).

REFER TO GENERAL DEMOLITION NOTES FOR ADDITIONAL NOTES.

2 EXISTING WALL FURRING AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED DOWN

TO EXISTING STRUCTURE.

3 EXISTING DOOR(S), FRAME AND ALL HARDWARE TO BE REMOVED.

4 EXISTING WINDOW(S), FRAME AND ALL COMPONENTS TO BE REMOVED.

5 EXISTING PLUMBING FIXTURE TO BE REMOVED. REFER TO MEP DEMO PLANS AND GENERAL

DEMOLITION NOTES FOR ADDITIONAL INFORMATION.

6 EXISTING BASE AND UPPER CABINETRY TO BE REMOVED.

7 EXISTING WALL HANDRAIL AND ALL OF ITS COMPONENTS TO BE REMOVED.

8 EXISTING FLOORING TO BE REMOVED. PREPARE AREA FOR NEW FLOOR FINISHES. ALL

FLOORING WITHIN PROJECT AREA TO BE REMOVED.

9 CONTRACTOR TO INSPECT AND REPAIR EXISTING PERIMETER WALLS NOT SCHEDULED FOR

DEMOLITION AS REQUIRED AND PREPARE SURFACE FOR NEW FINISH.

10 EXISTING CEILING AND GRID TO BE REMOVED. REFER TO GENERAL DEMOLITION NOTES FOR

ADDITIONAL INFORMATION. DEMOLITION INCLUDES DRYWALL AND PLASTER SOFFITS WITHIN

CEILING AREAS TO BE DEMOLISHED. ALL EXISTING CEILINGS WITHIN PROJECT AREA TO BE

REMOVED UNLESS NOTED OTHERWISE. SEE ELECTRICAL AND MECHANICAL DEMO PLANS

FOR REMOVAL OF CEILING MOUNTED DEVICES.

11 REF FLOOR FINISH PLAN FOR SELECTIVE DEMOLITION REQUIRED.

12 EXISTING DOORS, FRAME & HARDWARE TO REMAIN. PREP DOORS & FRAME FOR NEW PAINT

FINISH, REF. INTERIORS FOR FINISHES.

13 TEMPORARILY REMOVE EXISTING CEILING GRID AND TILES AS NECESSARY FOR

DEMO/INSTALL OF MECHANICAL (SEE MECH PLANS); REINSTALL GRID AND TILE AND REPAIR

ANY DAMAGES THAT OCCURED DURING CONSTRUCTION.

14 REMOVE PROJECTOR AND SCREEN AND OTHER RELATED EQUIPMENT AND RETURN TO

OWNER

15 EXISTING DRYWALL AND PLASTER TO BE REMOVED FROM COLUMNS.

16 GC TO COORDINATE REMOVAL/STORAGE & REINSTALLATION OF STAINED GLASS SHADOW

BOXES WITH COR.

17 GC TO COORDINATE REMOVAL/STORAGE & REINSTALLATION OF PEWS, PIANO AND

RELIGIOUS ARTIFACTS WITH COR.

18 EXISTING FLOOR TO BE DEMOLISHED TO ALLOW ACCESS TO EXISTING BEAM BELOW. REF

STRUCT. FOR ADDITION INFOMATION ON BEAM REINFORCING.

19 FLOAT SELF LEVELING CONCRETE OVER EXISTING MOSAIC FLOORING IN PREPARATION FOR

VINYL FLOORING

20 REMOVE EXISTING GYP CEILING AS NECESSARY FOR DEMO/INSTALL OF MECHANICAL (SEE

MECH PLAN); REPLACE, PATCH AND PAINT CEILING WHERE AFFECTED BY CONSTRUCTION.

ADD ACCESS PANELS AS REQUIRED TO SERVICE NEW MECHANICAL.

21 EXISTING GYP CEILING TO BE REMOVED. REFER TO GENERAL DEMOLITION NOTES FOR

ADDITIONAL INFORMATION. DEMOLITION INCLUDES DRYWALL AND PLASTER SOFFITS WITHIN

CEILING AREAS TO BE DEMOLISHED. ALL EXISTING CEILINGS WITHIN PROJECT AREA TO BE

REMOVED UNLESS NOTED OTHERWISE. SEE ELECTRICAL AND MECHANICAL DEMO PLANS

FOR REMOVAL OF CEILING MOUNTED DEVICES.

22 EXISTING GYP CEILING TO REMAIN.

23 AREA FOR PLUMBING CHASES THROUGH CONCRETE FLOOR-GC TO COORDINATE ALL NEW

PENETRATIONS AND DRILLING PER STRUCTURAL INSTRUCTIONS FOR DRILLING CONCRETE

SLAB

1" = 100'-0"

KEY PLAN - 2ND FLOOR

N

1/8" = 1'-0"

DEMOLITION PLAN - PARTIAL 2ND FLOOR

SEE SPECIFICATION SECTION 01 00 00 FOR FIELD VERIFICATION OF EXISTING CONCRETE

COLUMN, BEAM AND JOIST LOCATIONS.

SEE SPECIFICATION SECTION 01 00 00 FOR MANOMETER REQUIREMENTS AT EACH FLOOR

DURING CONSTRUCTION ACTIVITIES.

SEE SPECIFICATION SECTION 01 35 26 FOR INFECTION CONTROL REQUIREMENTS FOR THIS

PROJECT. REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO CONSTRUCTION PARTITIONS,

NEGATIVE AIR PRESSURE WITHIN CONSTRUCTION AREAS, AND PROVISIONS FOR ANTE ROOMS

AT CONSTRUCTION ENTRANCES.

Ea

Ea

F

F

G

G

Ga

Ga

H

H

J

J

Jb

Jb

K

K

L

L

La

La

M

M

N

N

Na

Na w 6.3 w 6.3

Ha

Ha

6.26.2

Ja

Ja

C330

SHADED AREA

NOT IN SCOPE

OF PROJECT

SHADED AREA

NOT IN SCOPE

OF PROJECT

1 1 1

2 2 2

2 2

3 3

3 3

3 3 3 3

3 3 3 3

3 3 3

3 3

5 5

5 5

5 5 5 5 55

7 5 6

8 8

8 8

8 8

1 1 1 1

1 1

1 1 1 1

1 1

1 1

11111111

1 1

1 1

1 1

1 1

1 1 1

11 1

1 1

1 1

11 1 1 1

9 9 9

9 9

9 9

9 9

1 1

23 23 23

BID ITEM #2D

BID ITEM #2E

PROJECT

LOCATION

CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.

THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE ARCHITECT OF ANY

CONDITIONS THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.

A.

GENERAL DEMOLITION NOTES:

PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY

DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

B.

VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE

DRAWINGS AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE

THE INTENDED WORK.

C.

ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS

RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL

WORK ASSOCIATED WITH THIS CONTRACT.

D.

CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH

SURROUNDING EXISTING FINISHES NOT DISTURBED.

E.

TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY

DEMOLITION NOTES ARE FOR GENERAL INFORMATION ONLY FROM INFORMATION

OBTAINED FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD

VERIFY MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS

BID.

F.

ALL APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION AND STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER. VA TO REMOVE ALL WALL

MOUNTED SYSTEMS FURNITURE AND FREE STANDING FURNITURE PRIOR TO

CONSTRUCTION

G.

MISCELLANEOUS FLOOR PENETRATIONS AND DEMO FOR NEW MECHANICAL AND

ELECTRICAL WORK SHALL BE COORDINATED FROM ARCHITECTURAL, MECHANICAL,

AND ELECTRICAL PLANS.

H.

REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DEMO PLANS FOR

DEMOLITION, SALVAGE AND RE-USE OF EXISTING ITEMS.

I.

PATCH FLOOR AT REMOVED WALLS AND CASEWORK, PREPARE FLOOR TO RECEIVE

NEW FLOORING AS REQUIRED.

J.

ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES TO RECEIVE

INFILL PER STRUCTURAL DETAIL.

K.

REMOVE ALL STAINLESS STEEL CORNER GUARDS CAREFULLY AND GIVE TO OWNER.L.

ELEMENTS INDICATED WITH A DASHED LINE ARE TO BE DEMOLISHED AND

DISPOSED OF AS A PART OF THIS PROJECT, UNLESS NOTED OTHERWISE.

M.

IN EXISTING AREAS, RENOVATION AND DEMOLITION WORK SHALL BE ACCOMPLISHED

WITH MINIMAL DISRUPTION TO OPERATIONS. IF REQUIRED, THE OWNER RESERVES THE

RIGHT TO TEMPORARILY STOP WORK OF SPECIFIC CONSTRUCTION OPERATIONS

SHOULD THE OWNER IDENTIFY AN EMERGENCY OR DANGER EXISTS TO THE WELFARE

OF THE OCCUPANTS ON ACCOUNT OF SUCH WORK OR OPERATIONS.

N.

CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER

NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.

O.

IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL

BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING

ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT ARE NOT

SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND CONTINUE ANY

SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.

P.

ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT ARE TO BE REMOVED SHALL BE

DISCONNECTED AT SOURCE AND REMOVED.

Q.

ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT

THAT ARE TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED

ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,

TO BE…