About this file

36C25219B0013 0001 S06 - A00001 - Att 3 - Door Schedule G001.pdf

View the file

Other files for this federal contract opportunity

Other files attached to 585-16-116 Replace Fire Doors and Frames at Oscar G. Johnson VAMC at Iron Mountain, MI, newest first.
File Type Posted
36C25219C0061-000.docx DOCX document
36C25219B0013_0004.docx DOCX document
36C25219B0013_0003.docx DOCX document
S06_-_A00002_-_Att1_Addendum__2_-_585-16-116.docx DOCX document
S06_-_A00002_-_Att2_BidForm_-_585-16-116.docx DOCX document
S06_-_A00002_-_Att3_-_Signage_Spec_-_585-16-116.pdf PDF
36C25219B0013_0002.docx DOCX document
36C25219B0013-0001000.docx DOCX document
36C25219B0013-0001004.pdf PDF
36C25219B0013-0001001.docx DOCX document
36C25219B0013-0001006.pdf PDF
36C25219B0013-0001005.docx DOCX document
36C25219B0013-0001002.pdf PDF
36C25219B0013-004.docx DOCX document
36C25219B0013-003.pdf PDF
36C25219B0013-001.docx DOCX document
36C25219B0013-002.pdf PDF
36C25219B0013-000.docx DOCX document
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOOR SCHEDULE ‐ ADDENDUM #1 ‐ 585‐16‐116 REPLACE FIRE DOORS AND FRAMES 3‐Dec‐18

FLOOR

DOOR

NUMBER

DOOR

ELEVATION

DOOR

MATERIAL

DOOR

CORE

DOOR

WIDTH

DOOR

HEIGHT

DOOR

GLAZING

FRAME

ELEVATION

FRAME

MATERIAL

FRAME

GLAZING

HEAD JAMB SILL LABEL

HARDWARE

SET

KEYED NOTES* NOTES ALLOWABLE INSTALLATION TIMES

0 SB‐P2.1 B

HOLLOW

METAL

MINERAL 30" 7'‐0" ‐ HF‐1

HOLLOW

METAL

J1 90 MINUTE 6

0 SB‐P2.2 B

HOLLOW

METAL

MINERAL 30" 7'‐0" ‐ HF‐1

HOLLOW

METAL

J1 90 MINUTE 6

0 SB‐S2.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1

RAISE (2) FIRE ALARM/STROBES, REMOVE AND CAP

EMPTY ELECTRICAL CONDUIT

ANY SHIFT

00B B284 B

HOLLOW

METAL

MINERAL 30 7'‐0" ‐ HF‐1

HOLLOW

METAL

J1 90 MINUTE 6 NIGHT SHIFT

00B B‐S2.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 RAISE LIGHTED "STAIR" SIGN NIGHT SHIFT

00B B‐S3.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 INSTALL DOOR STOP NIGHT SHIFT

00B B‐S5.1 D

HOLLOW

METAL

MINERAL 40" 7'‐0" 1" INSULATED HF‐1

HOLLOW

METAL

J2 ‐ 7 A, B

EXTERIOR DOOR, REMOVE AND REINSTALL

"GENTEX" ALARM, REMOVE AND REINSTALL CARD

READER

DAY SHIFT

01 1‐C1.1 C

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐2

HOLLOW

METAL

J1 90 MINUTE 8 B, C WANDER GUARD, POWER OPERATED OPENERS NIGHT SHIFT

01 1‐C1.2 C

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐2

HOLLOW

METAL

J1 90 MINUTE 8 B, C WANDER GUARD, POWER OPERATED OPENERS NIGHT SHIFT

01 1‐S1.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 RAISE EXIT SIGN DAY/AFTERNOON SHIFT

01 1‐S1.2 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 9 B, C WANDER GUARD DAY/AFTERNOON SHIFT

01 1‐S2.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 NIGHT SHIFT

01 1‐S3.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 2 LOW SOFFIT ANY SHIFT

01 1‐S4.1 D

HOLLOW

METAL

MINERAL 40" 7'‐0" 1" INSULATED HF‐1

HOLLOW

METAL

J2 ‐ 7 A, B

EXTERIOR DOOR, REMOVE AND REINSTALL

"GENTEX" ALARM, REMOVE AND REINSTALL

GROUND WIRE

DAY SHIFT

01 1‐S4.2 REMOVED FROM PROJECT

01 1‐S5.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 9 WANDER GUARD DAY/AFTERNOON SHIFT

02 2‐S2.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 NIGHT SHIFT

02 2‐S3.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 3 B NIGHT SHIFT

02 2‐S4.1 A

HOLLOW

METAL

MINERAL 36 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 B

7'‐0' EXISTING DOOR, ADJACENT TO BUILDING

EXPANSION/CONTROL JOINT

NIGHT SHIFT

02 2‐S5.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 3 B NIGHT SHIFT

03 3‐S1.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 3 B RAISE WIFI, MOVE EXIT SIGN DAY/AFTERNOON SHIFT

03 3‐S2.1 A

HOLLOW

METAL

MINERAL 48" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J2 90 MINUTE 1 NIGHT SHIFT

03 3‐S2.2 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 2 NIGHT SHIFT

03 3‐S3.1 A

HOLLOW

METAL

MINERAL 42" 7'‐0"

FIRE RATED

GLASS

‐ EXISTING ‐ 90 MINUTE 1 EXISTING FRAME TO REMAIN NIGHT SHIFT

03 3‐S5.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 3 B NIGHT SHIFT

04 4‐S1.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 RAISE SPRINKLER NIGHT SHIFT

04 4‐S2.1 A

HOLLOW

METAL

MINERAL 40" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J2 90 MINUTE 5 B, C WANDER GUARD, LOW SOFFIT DAY/AFTERNOON SHIFT

04 4‐S3.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 5 B, C WANDER GUARD, RAISE WIFI DAY/AFTERNOON SHIFT

04 4‐S5.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 3 B, C REMOVE OLD LOCK, PATCH WALL NIGHT SHIFT

05 5‐S2.1 A

HOLLOW

METAL

MINERAL 36" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 LOW SOFFIT NIGHT SHIFT

05 5‐S2.2 B

HOLLOW

METAL

MINERAL 44" 7'‐0" ‐ HF‐1

HOLLOW

METAL

J1 90 MINUTE 3 B NIGHT SHIFT

05 5‐S3.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 RAISE WALL MOUNTED LIGHTS NIGHT SHIFT

05 5‐S4.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1

REMOVE OLD MAG LOCK BUTTON AND WIRE

MOLDING, PATCH

NIGHT SHIFT

06 6‐S1.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 NIGHT SHIFT

06 6‐S2.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 1 NIGHT SHIFT

06 6‐S3.1 A

HOLLOW

METAL

MINERAL 44" 7'‐0"

FIRE RATED

GLASS

HF‐1

HOLLOW

METAL

J1 90 MINUTE 3 B REMOVE AND REINSTALL ELECTRIC JUNCTION BOX NIGHT SHIFT

KEYED NOTES

* UNLESS OTHERWISE NOTED, ASSUME ALL EXISTING DOORS AND FRAMES ARE 6'‐8" ‐ MODIFY EXISTING WALL OPENINGS AS REQUIRED

A. EXTERIOR DOOR

B. ELECTRONIC ACCESS CONTROL ‐ COORDINATE WITH ELECTRICAL DRAWINGS AND HARDWARE SPECIFICATIONS

C. REMOVE AND REINSTALL EXISTING WANDER GUARD

ELEVATOR ACCESS ROOMS, DISCONNECT AND

RECONNECT ELEVATOR INTERLOCK DOOR

CONTACT SWITCH

(INSTALLATION TO BE COORDINATED WITH

VA. WORK TO BEGIN AT 3PM ON A FRIDAY

AND BE COMPLETED BY 8AM THE FOLLOWING

MONDAY ‐ ONLY 1 ELEVATOR IS TO BE