36C25219B0013-0001003.pdf
PDF 79 KB Posted
- Attached to
- 585-16-116 Replace Fire Doors and Frames at Oscar G. Johnson VAMC at Iron Mountain, MI Federal contract opportunity
- Solicitation number
- 36C25219B0013
About this file
36C25219B0013 0001 S06 - A00001 - Att 3 - Door Schedule G001.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25219C0061-000.docx | DOCX document | |
| 36C25219B0013_0004.docx | DOCX document | |
| 36C25219B0013_0003.docx | DOCX document | |
| S06_-_A00002_-_Att1_Addendum__2_-_585-16-116.docx | DOCX document | |
| S06_-_A00002_-_Att2_BidForm_-_585-16-116.docx | DOCX document | |
| S06_-_A00002_-_Att3_-_Signage_Spec_-_585-16-116.pdf | ||
| 36C25219B0013_0002.docx | DOCX document | |
| 36C25219B0013-0001000.docx | DOCX document | |
| 36C25219B0013-0001004.pdf | ||
| 36C25219B0013-0001001.docx | DOCX document | |
| 36C25219B0013-0001006.pdf | ||
| 36C25219B0013-0001005.docx | DOCX document | |
| 36C25219B0013-0001002.pdf | ||
| 36C25219B0013-004.docx | DOCX document | |
| 36C25219B0013-003.pdf | ||
| 36C25219B0013-001.docx | DOCX document | |
| 36C25219B0013-002.pdf | ||
| 36C25219B0013-000.docx | DOCX document |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DOOR SCHEDULE ‐ ADDENDUM #1 ‐ 585‐16‐116 REPLACE FIRE DOORS AND FRAMES 3‐Dec‐18
FLOOR
DOOR
NUMBER
DOOR
ELEVATION
DOOR
MATERIAL
DOOR
CORE
DOOR
WIDTH
DOOR
HEIGHT
DOOR
GLAZING
FRAME
ELEVATION
FRAME
MATERIAL
FRAME
GLAZING
HEAD JAMB SILL LABEL
HARDWARE
SET
KEYED NOTES* NOTES ALLOWABLE INSTALLATION TIMES
0 SB‐P2.1 B
HOLLOW
METAL
MINERAL 30" 7'‐0" ‐ HF‐1
HOLLOW
METAL
J1 90 MINUTE 6
0 SB‐P2.2 B
HOLLOW
METAL
MINERAL 30" 7'‐0" ‐ HF‐1
HOLLOW
METAL
J1 90 MINUTE 6
0 SB‐S2.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1
RAISE (2) FIRE ALARM/STROBES, REMOVE AND CAP
EMPTY ELECTRICAL CONDUIT
ANY SHIFT
00B B284 B
HOLLOW
METAL
MINERAL 30 7'‐0" ‐ HF‐1
HOLLOW
METAL
J1 90 MINUTE 6 NIGHT SHIFT
00B B‐S2.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 RAISE LIGHTED "STAIR" SIGN NIGHT SHIFT
00B B‐S3.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 INSTALL DOOR STOP NIGHT SHIFT
00B B‐S5.1 D
HOLLOW
METAL
MINERAL 40" 7'‐0" 1" INSULATED HF‐1
HOLLOW
METAL
J2 ‐ 7 A, B
EXTERIOR DOOR, REMOVE AND REINSTALL
"GENTEX" ALARM, REMOVE AND REINSTALL CARD
READER
DAY SHIFT
01 1‐C1.1 C
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐2
HOLLOW
METAL
J1 90 MINUTE 8 B, C WANDER GUARD, POWER OPERATED OPENERS NIGHT SHIFT
01 1‐C1.2 C
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐2
HOLLOW
METAL
J1 90 MINUTE 8 B, C WANDER GUARD, POWER OPERATED OPENERS NIGHT SHIFT
01 1‐S1.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 RAISE EXIT SIGN DAY/AFTERNOON SHIFT
01 1‐S1.2 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 9 B, C WANDER GUARD DAY/AFTERNOON SHIFT
01 1‐S2.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 NIGHT SHIFT
01 1‐S3.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 2 LOW SOFFIT ANY SHIFT
01 1‐S4.1 D
HOLLOW
METAL
MINERAL 40" 7'‐0" 1" INSULATED HF‐1
HOLLOW
METAL
J2 ‐ 7 A, B
EXTERIOR DOOR, REMOVE AND REINSTALL
"GENTEX" ALARM, REMOVE AND REINSTALL
GROUND WIRE
DAY SHIFT
01 1‐S4.2 REMOVED FROM PROJECT
01 1‐S5.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 9 WANDER GUARD DAY/AFTERNOON SHIFT
02 2‐S2.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 NIGHT SHIFT
02 2‐S3.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 3 B NIGHT SHIFT
02 2‐S4.1 A
HOLLOW
METAL
MINERAL 36 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 B
7'‐0' EXISTING DOOR, ADJACENT TO BUILDING
EXPANSION/CONTROL JOINT
NIGHT SHIFT
02 2‐S5.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 3 B NIGHT SHIFT
03 3‐S1.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 3 B RAISE WIFI, MOVE EXIT SIGN DAY/AFTERNOON SHIFT
03 3‐S2.1 A
HOLLOW
METAL
MINERAL 48" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J2 90 MINUTE 1 NIGHT SHIFT
03 3‐S2.2 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 2 NIGHT SHIFT
03 3‐S3.1 A
HOLLOW
METAL
MINERAL 42" 7'‐0"
FIRE RATED
GLASS
‐ EXISTING ‐ 90 MINUTE 1 EXISTING FRAME TO REMAIN NIGHT SHIFT
03 3‐S5.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 3 B NIGHT SHIFT
04 4‐S1.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 RAISE SPRINKLER NIGHT SHIFT
04 4‐S2.1 A
HOLLOW
METAL
MINERAL 40" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J2 90 MINUTE 5 B, C WANDER GUARD, LOW SOFFIT DAY/AFTERNOON SHIFT
04 4‐S3.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 5 B, C WANDER GUARD, RAISE WIFI DAY/AFTERNOON SHIFT
04 4‐S5.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 3 B, C REMOVE OLD LOCK, PATCH WALL NIGHT SHIFT
05 5‐S2.1 A
HOLLOW
METAL
MINERAL 36" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 LOW SOFFIT NIGHT SHIFT
05 5‐S2.2 B
HOLLOW
METAL
MINERAL 44" 7'‐0" ‐ HF‐1
HOLLOW
METAL
J1 90 MINUTE 3 B NIGHT SHIFT
05 5‐S3.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 RAISE WALL MOUNTED LIGHTS NIGHT SHIFT
05 5‐S4.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1
REMOVE OLD MAG LOCK BUTTON AND WIRE
MOLDING, PATCH
NIGHT SHIFT
06 6‐S1.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 NIGHT SHIFT
06 6‐S2.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 1 NIGHT SHIFT
06 6‐S3.1 A
HOLLOW
METAL
MINERAL 44" 7'‐0"
FIRE RATED
GLASS
HF‐1
HOLLOW
METAL
J1 90 MINUTE 3 B REMOVE AND REINSTALL ELECTRIC JUNCTION BOX NIGHT SHIFT
KEYED NOTES
* UNLESS OTHERWISE NOTED, ASSUME ALL EXISTING DOORS AND FRAMES ARE 6'‐8" ‐ MODIFY EXISTING WALL OPENINGS AS REQUIRED
A. EXTERIOR DOOR
B. ELECTRONIC ACCESS CONTROL ‐ COORDINATE WITH ELECTRICAL DRAWINGS AND HARDWARE SPECIFICATIONS
C. REMOVE AND REINSTALL EXISTING WANDER GUARD
ELEVATOR ACCESS ROOMS, DISCONNECT AND
RECONNECT ELEVATOR INTERLOCK DOOR
CONTACT SWITCH
(INSTALLATION TO BE COORDINATED WITH
VA. WORK TO BEGIN AT 3PM ON A FRIDAY
AND BE COMPLETED BY 8AM THE FOLLOWING
MONDAY ‐ ONLY 1 ELEVATOR IS TO BE
File details come from the government source that posted it.