36C25218B1081-0002002.pdf
PDF 4 MB Posted
- Attached to
- Demolition CLC Ward-3C Bldg-134 556-14-011
- Solicitation number
- 36C25218B1081
About this file
36C25218B1081 0002 556-14-011 - 134-3C Demo Drwgs 2018-08-04.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25218B1081-0003000.docx | DOCX document | |
| 36C25218B1081-0002003.pdf | ||
| 36C25218B1081-0002001.pdf | ||
| 36C25218B1081-0002004.pdf | ||
| 36C25218B1081-0002000.docx | DOCX document | |
| 36C25218B1081-0001004.pdf | ||
| 36C25218B1081-0001003.pdf | ||
| 36C25218B1081-0001001.pdf | ||
| 36C25218B1081-0001000.docx | DOCX document | |
| 36C25218B1081-0001002.pdf | ||
| 36C25218B1081-002.pdf | ||
| 36C25218B1081-003.pdf | ||
| 36C25218B1081-001.docx | DOCX document | |
| 36C25218B1081-000.docx | DOCX document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT SITE:
BLDG. 134
VHANCHMarriC Text Box For Bid Set 08/04/2018
VHANCHMarriC Typewritten Text AD102.A Contractor office a Fire/Infection Control barrier
F JG
E
H
DA CB
LK
S
Key Plan
PART THIRD FLOOR PLAN
ASBESTOS ABATEMENT
DOMESTIC WATER PIPING & MECHANICAL
ASBESTOS DRAWING NOTES:
REMOVE ASBESTOS MATERIALS AS REQUIRED, HARD FITTINGS AT ALL SINKS ON FLOORS 3.
REMOVE ASBESTOS MATERIALS AS REQUIRED, HARD FITTINGS ON TOILET SUPPLIES, FLOORS 3.
REMOVE ASBESTOS MATERIALS AS REQUIRED, HARD FITTINGS ON PIPES TO RADIATORS, FLOORS 3, TRANSITE PANEL IN RADIATOR CAVITY SHALL BE REMOVED, APPROXIMATELY 8 SQUARE FOOT
PANEL, 1 AT EACH RADIATOR.
NO ASBESTOS MATERIALS OBSERVED ON RADIATOR CASE, FRAME OR COIL EXCEPT AS NOTED IN 3
ABOVE.
NO ASBESTOS MATERIALS OBSERVED ON AHU EXCEPT HARD FITTINGS ON PIPING TO AHU COIL.
REMOVE ASBESTOS MATERIALS AS REQUIRED; HARD FITTINGS ON STORM PIPES.
REMOVE ASBESTOS MATERIALS AS REQUIRED; HARD FITTINGS ON SUPPLY PIPES LAUNDRY
ROOM FIXTURES.
REMOVE ASBESTOS MATERIALS AS REQUIRED; HARD FITTINGS ON SUPPLY PIPES TO BEDPAN WASH.
REMOVE ASBESTOS MATERIALS AS REQUIRED; HARD FITTINGS ON SUPPLY PIPES TO SHOWER/BATHTUB.
REMOVE ASBESTOS MATERIALS AS REQUIRED; HARD FITTINGS ON SUPPLY PIPES TO JANITOR/HAC SINK.
REMOVE ASBESTOS MATERIALS AS REQUIRED; HARD FITTINGS ON SUPPLY PIPE TO DRINKING FOUNTAIN.
GENERAL NOTES:
ESTIMATED REMOVAL QUANTITIES:
ASBESTOS ABATEMENT NOTES:
I D
E
VHANCHMarriC Text Box For Bid Set 08/04/2018
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Typewritten Text
VHANCHMarriC Polygon
J
Jx Kx Lx
KyJyHzHxFx
Hy
25 24
KEY PLAN
C-WING
A-WING B-WING
N
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Callout Location for 2 hour fire rated barrier / Infection Control Barrier Barrier to remain at end of demolition contract work.
VHANCHMarriC Rectangle
VHANCHMarriC Callout Area outside demolition / construction area for use by contractor for office and equipment storage.
VHANCHMarriC Text Box
NOTE: NO CONTRACT DEMOLITION WORK IS SHOWN N THIS SHEET
Contract work on this sheet is limited to;
- Fire/infection control barrier
- Contractor office area location
VHANCHMarriC Text Box For Bid Set 08/04/2018
VHANCHMarriC Rectangle
VHANCHMarriC Rectangle
VHANCHMarriC Text Box
GENERAL PROJECT NOTES
- The general intent of the project is to provide a complete demolition of interior finishes and noted systems and provide an area ready for renovation and new finishes.
F JG
E
H
DA CB
LK
F.E.C.
F.E.C.
F.E.C.
SOFFIT
( 19" DROP)
UTILITY SINK
(AT FLOOR)
OLD DOOR,
SEALED CLOSED
2 ELECTRICAL PANELS
STANDPIPE
STANDPIPE
DOWN
DOWN
2 SHOWER STALLS
9'-2" CEILING
CEILING 9'-5"
ACT BACK 16"
ELECTRICAL
PANEL
CEILING 8'-0"
PLASTER
CEILING
BULKHEAD
ELECTRICAL PANEL
ELECTRICAL
PANEL
KEY PLAN
C-WING
A-WING B-WING
N
13100 watertown plank road suite 200 elm grove, wi 53122
Nagel Architects Project Number: 140701
Altus Architectural Studios, Inc.
12925 W. Dodge Road Omaha, Nebraska 68154
American Structurepoint, Inc.
7260 Shadeland Station Indianapolis, IN 46256
Avantti Environmental Group 309 North Water Street Suite 650 Milwaukee, WI 53202
Middleton Construction Consulting 330 East Kilbourn Ave Suite 565 Milwaukee, WI 53202
Specialized Engineering Solutions, Inc.
10360 Ellison Circle Omaha, Nebraska 68134
IN PLACE OF REMOVED COMPONANTS
WINDOW DESIGN AND APPEARANCE
VHANCHMarriC Text Box For Bid Set 08/04/2018
VHANCHMarriC Text Box Infection Control / Negative pressure information notes;
- There are approximately twenty-two (22) 6" x 16" vents in the exterior masonry wall, above the ceiling level, which will require covering/sealing so as to meet negative pressure requirements. Temporary cover/seal shall be removed prior to end of project in accordance with COR and Infection Control reviews/approval.
- There is approximately one (1) 24" x 24" roof vent above the ceiling level, near the corridor intersection, which will require covering/sealing so as to meet negative pressure requirements. Temporary cover/seal shall be removed prior to end of project in accordance with COR and Infection Control reviews/approval.
VHANCHMarriC Text Box
GENERAL DEMOLITION NOTES CONTINUED
18. All VCT floor tile and mastic shall be removed throughout the construction zone.
19. Remove epoxy flooring and/or epoxy covered ceramic tile and prepare exiting deck for future finishes.
VHANCHMarriC Line
VHANCHMarriC Callout Remove loose plaster
Loose plaster is plaster that can be removed with a wire brush.
Scope of plaster removal is all exterior walls.
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
VHANCHMarriC Text Box
TYP
VHANCHMarriC Text Box
VHANCHMarriC Text Box
GENERAL PROJECT NOTES
- The general intent of the project is to provide a complete demolition of interior finishes and noted systems and provide an area ready for renovation and new finishes.
VHANCHMarriC Callout If chute is used for removal of materials, this is the intended location for the chute and dumpster.
- This location has three full stories below floor level of the construction area to exterior grade level.
- Contractor will repair any damage to existing concrete curb and grass area created by the use of chute/dumpster.
- The chute / dumpster area will be enclosed with a temporary construction fence with gate. Gate shall be kept closed at all times except when in use.
- The window opening for the chute will be protected such that inclement weather will not impact the building.
Polygon
F JG
E
H
DA CB
LK
F.E.C.
F.E.C.
F.E.C.
SOFFIT
( 19" DROP)
UTILITY SINK
(AT FLOOR)
OLD DOOR,
SEALED CLOSED
2 ELECTRICAL PANELS
STANDPIPE
STANDPIPE
DOWN
DOWN
2 SHOWER STALLS
9'-2" CEILING
CEILING 9'-5"
ACT BACK 16"
ELECTRICAL
PANEL
CEILING 8'-0"
PLASTER
CEILING
S S
S
SMK
SMK
SPEAKER
SMK
SPEAKER
S
S
S
S
S
S
SMK
S
S S
SPEAKER
BULKHEAD
S
SMK
SMK
SMK
SMK
ELECTRICAL PANEL
ELECTRICAL
PANEL
S
S
S
S S
SMK
SPEAKER
S
KEY PLAN
C-WING
A-WING B-WING
N
13100 watertown plank road suite 200 elm grove, wi 53122
Nagel Architects Project Number: 140701
Altus Architectural Studios, Inc.
12925 W. Dodge Road Omaha, Nebraska 68154
American Structurepoint, Inc.
7260 Shadeland Station Indianapolis, IN 46256
Avantti Environmental Group 309 North Water Street Suite 650 Milwaukee, WI 53202
Middleton Construction Consulting 330 East Kilbourn Ave Suite 565 Milwaukee, WI 53202
Specialized Engineering Solutions, Inc.
10360 Ellison Circle Omaha, Nebraska 68134
VHANCHMarriC Text Box For Bid Set 08/04/2018
VHANCHMarriC Text Box Fire Suppression System (Sprinkler) Notes;
- The sprinkler system shall remain active until the 2 hour fire barrier/infection control is completed and inspected by FHCC Safety and Infection Control.
- During a coordinated outage, the sprinkler system main piping from the stainwells shall be cut and capped within the construction zone, near each stairwell.
VHANCHMarriC Typewritten Text removed and turned over to the FHCC COR
VHANCHMarriC Typewritten Text
SEE NOTES
VHANCHMarriC Typewritten Text
SEE NOTES
VHANCHMarriC Typewritten Text
SEE NOTES
VHANCHMarriC Text Box
CEILING MOUNTED SMOKE DETECTOR NOTES
- In coordination with the FHCC fire alarm technician, the existing fire alarm system shall be revised to remove smoke detectors and install heat detectors.
- The FHCC will provide, install and programming system for revised detectors.
- The demolition contractor shall protect the existing fire alarm wiring to remain and provide support for raceways as required for remaining system wiring.
- Fire alarm activation pull stations will remain at the stairwells.
VHANCHMarriC Text Box
CEILING MOUNTED EXIT SIGN NOTES;
- The contractor shall maintain functional exit signs at each stairwell and construction entrance.
13100 watertown plank road suite 200 elm grove, wi 53122
Nagel Architects Project Number: 140701
Altus Architectural Studios, Inc.
12925 W. Dodge Road Omaha, Nebraska 68154
American Structurepoint, Inc.
7260 Shadeland Station Indianapolis, IN 46256
Avantti Environmental Group 309 North Water Street Suite 650 Milwaukee, WI 53202
Middleton Construction Consulting 330 East Kilbourn Ave Suite 565 Milwaukee, WI 53202
Specialized Engineering Solutions, Inc.
10360 Ellison Circle Omaha, Nebraska 68134
VHANCHMarriC Text Box For Bid Set 08/04/2018
F JG
E
H
DA CB
LK
13100 watertown plank road suite 200 elm grove, wi 53122
Nagel Architects Project Number: 140701
Altus Architectural Studios, Inc.
12925 W. Dodge Road Omaha, Nebraska 68154
American Structurepoint, Inc.
7260 Shadeland Station Indianapolis, IN 46256
Avantti Environmental Group 309 North Water Street Suite 650 Milwaukee, WI 53202
Middleton Construction Consulting 330 East Kilbourn Ave Suite 565 Milwaukee, WI 53202
Specialized Engineering Solutions, Inc.
10360 Ellison Circle Omaha, Nebraska 68134
KEY PLAN
C-WING
A-WING B-WING
N
VHANCHMarriC Text Box For Bid Set 08/04/2018
VHANCHMarriC Text Box A306A
VHANCHMarriC Callout Complete demolition of exhaust duct run into next room to the north, A306A. Insert ceiling tile into removed diffuser space. Infill duct penetration to maintain fire/infection control requirements.
VHANCHMarriC Callout Demolish duct to north side of Line 16/17 and properly cap existing supply duct to remain. Infill duct penetration to maintain fire/infection control requirements.
VHANCHMarriC Text Box Mechanical Piping Demolition Notes:
- The FHCC will cut and cap the mechanical heating piping below the third floor prior to the start of the demolition work.
- The demolition contractor is responsible to remove the convector and piping to the point it has been cut.
- The demolition contractor is responsible to properly infill any piping penetrations through fire rated barriers (floors).
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Callout Cap duct at roof penetration to maintain infection control negative pressure requirements.
13100 watertown plank road suite 200 elm grove, wi 53122
Nagel Architects Project Number: 140701
Altus Architectural Studios, Inc.
12925 W. Dodge Road Omaha, Nebraska 68154
American Structurepoint, Inc.
7260 Shadeland Station Indianapolis, IN 46256
Avantti Environmental Group 309 North Water Street Suite 650 Milwaukee, WI 53202
Middleton Construction Consulting 330 East Kilbourn Ave Suite 565 Milwaukee, WI 53202
Specialized Engineering Solutions, Inc.
10360 Ellison Circle Omaha, Nebraska 68134
VHANCHMarriC Text Box
F JG
E
H
DA CB
LK
F.E.C.
F.E.C.
F.E.C.
SOFFIT
( 19" DROP)
UTILITY SINK
(AT FLOOR)
OLD DOOR,
SEALED CLOSED
2 ELECTRICAL PANELS
STANDPIPE
STANDPIPE
DOWN
DOWN
2 SHOWER STALLS
9'-2" CEILING
CEILING 9'-5"
ACT BACK 16"
ELECTRICAL
PANEL
CEILING 8'-0"
PLASTER
CEILING
BULKHEAD
ELECTRICAL PANEL
ELECTRICAL
PANEL
13100 watertown plank road suite 200 elm grove, wi 53122
Nagel Architects Project Number: 140701
Altus Architectural Studios, Inc.
12925 W. Dodge Road Omaha, Nebraska 68154
American Structurepoint, Inc.
7260 Shadeland Station Indianapolis, IN 46256
Avantti Environmental Group 309 North Water Street Suite 650 Milwaukee, WI 53202
Middleton Construction Consulting 330 East Kilbourn Ave Suite 565 Milwaukee, WI 53202
Specialized Engineering Solutions, Inc.
10360 Ellison Circle Omaha, Nebraska 68134
KEY PLAN
C-WING
A-WING B-WING
N
Text Box For Bid Set 08/04/2018
VHANCHMarriC Text Box Plumbing Piping Demolition Notes:
- The FHCC will cut and cap the plumbing SUPPLY piping below the third floor prior to the start of the demolition work.
- The demolition contractor is responsible to remove the supply piping to the point it has been cut. All other plumbing piping noted for demolition is the contractors responsibility.
- The demolition contractor is responsible to properly infill any piping penetrations through fire rated barriers (floors).
VHANCHMarriC Line
VHANCHMarriC Line
Line
Text Box
F JG
E
H
DA CB
LK
F.E.C.
F.E.C.
F.E.C.
SOFFIT
( 19" DROP)
UTILITY SINK
(AT FLOOR)
OLD DOOR,
SEALED CLOSED
2 ELECTRICAL PANELS
STANDPIPE
STANDPIPE
DOWN
DOWN
2 SHOWER STALLS
9'-2" CEILING
CEILING 9'-5"
ACT BACK 16"
ELECTRICAL
PANEL
CEILING 8'-0"
PLASTER
CEILING
S S
S
S
S
S
S
S
S
S
S S
BULKHEAD
S
ELECTRICAL PANEL
ELECTRICAL
PANEL
S
S
S
S S
13100 watertown plank road suite 200 elm grove, wi 53122
Nagel Architects Project Number: 140701
Altus Architectural Studios, Inc.
12925 W. Dodge Road Omaha, Nebraska 68154
American Structurepoint, Inc.
7260 Shadeland Station Indianapolis, IN 46256
Avantti Environmental Group 309 North Water Street Suite 650 Milwaukee, WI 53202
Middleton Construction Consulting 330 East Kilbourn Ave Suite 565 Milwaukee, WI 53202
Specialized Engineering Solutions, Inc.
10360 Ellison Circle Omaha, Nebraska 68134
KEY PLAN
C-WING
A-WING B-WING
N
VHANCHMarriC Text Box For Bid Set 08/04/2018
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Typewritten Text
6. Remove complete Wanderguard system including panels in C315, sensors at exits, keypads, and associated wiring and raceways.
VHANCHMarriC Inserted Text
VHANCHMarriC Typewritten Text 6.
13100 watertown plank road suite 200 elm grove, wi 53122
Nagel Architects Project Number: 140701
Altus Architectural Studios, Inc.
12925 W. Dodge Road Omaha, Nebraska 68154
American Structurepoint, Inc.
7260 Shadeland Station Indianapolis, IN 46256
Avantti Environmental Group 309 North Water Street Suite 650 Milwaukee, WI 53202
Middleton Construction Consulting 330 East Kilbourn Ave Suite 565 Milwaukee, WI 53202
Specialized Engineering Solutions, Inc.
10360 Ellison Circle Omaha, Nebraska 68134
VHANCHMarriC Text Box For Bid Set 08/04/2018
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Line
VHANCHMarriC Polygon
VHANCHMarriC Typewritten Text Remove Panels
VHANCHMarriC Typewritten Text
VHANCHMarriC Typewritten Text
VHANCHMarriC Oval
VHANCHMarriC Oval
VHANCHMarriC Typewritten Text
Oval
File details come from the government source that posted it.