B26 As-Built Drawings - Electrical.pdf

PDF 9 MB Posted

Attached to
H959--5 Year Arc Flash Survey Federal contract opportunity
Solicitation number
36C25022Q1134
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

View the file

Other files for this federal contract opportunity

Other files attached to H959--5 Year Arc Flash Survey, newest first.
File Type Posted
36C25022Q1134 0002.docx DOCX document
Elect Single Line 2.pdf PDF
Elect Single Line 1.pdf PDF
B26 As-Built Drawings - Electrical (1-lines and Schedules).pdf PDF
36C25022Q1134 0001.docx DOCX document
B31 Secondary.pdf PDF
Pages from B18 Machine Room As-builts.pdf PDF
36C25022Q1134.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J

OS

PC

GENERAL NOTES

ELECTRICAL SHEET INDEX

FIRE-STOPPING NOTES

OCCUPANCY SENSOR NOTES

SCALE: NONE

OCCUPANCY SENSOR DETAIL #1

(NOT ALL ITEMS

MAY APPLY)

(NOT ALL ITEMS

MAY APPLY)

B1 b

B1

H1

H1 b

E

E E

E

CT

A

A

SECTION A-A

SECTION A-A

A

A

A

A

SECTION A-A

SYSTEM #C-AJ-1226

4B

SYSTEM #C-AJ-1388

4A

4B 1

SYSTEM #W-L-2075

1B

1A

L RATING AT 400 F - 4 CFM/SQ FT

L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT

1. FLOOR OR WALL ASSEMBLY MIN 4-1/2 IN. THICK REINFORCED LIGHTWEIGHT

OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED

OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAM OF OPENING IS 32 IN.

2. METALLIC SLEEVE (OPTIONAL) NOM 32 IN. DIAM (OR SMALLER) SCHEDULE 40

(OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY,

FLUSH WITH FLOOR OR WALL SURFACES.

3. THROUGH-PENETRANT ONE METALLIC PIPE OR CONDUIT TO BE INSTALLED EITHER

CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE

BETWEEN PIPE OR CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 0 IN.

(POINT CONTACT) TO MAX 1-7/8 IN. PIPE MAY BE INSTALLED WITH CONTINUOUS POINT

CONTACT. PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL

ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY BE USED:

A. STEEL PIPE NOM 30 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.

B. IRON PIPE NOM 30 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.

C. COPPER PIPE NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.

D. COPPER TUBING NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.

E. CONDUIT NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT.

F. CONDUIT NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT).

4. FIRESTOP SYSTEM THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:

A. PACKING MATERIAL MIN 4 IN. THICKNESS OF MIN 4 PCF MINERAL WOOL

BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM.

PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM

BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED

THICKNESS OF FILL MATERIAL.

B. FILL, VOID OR CAVITY MATERIAL* -- SEALANT MIN 1/4 IN. THICKNESS

OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF

FLOOR OR WITH BOTH SURFACES OF WALL. AT THE POINT OR CONTINUOUS

CONTACT LOCATIONS BETWEEN PIPE AND CONCRETE, A MIN 1/4 IN. DIAM

BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE CONCRETE/PIPE INTERFACE

ON THE TOP SURFACE OF FLOOR AND ON BOTH SURFACES OF WALL.

HILTI CONSTRUCTION CHEMICALS, DIV OF

HILTI INC - FS-ONE SEALANT

*BEARING THE UL CLASSIFICATION MARKING

1. FLOOR OR WALL ASSEMBLY MIN 4-1/2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE

BLOCKS*. MAX AREA OF OPENING 224 SQ IN. WITH MAX DIMENSION OF 32 IN.

SEE CONCRETE BLOCKS (CAZT) IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS.

2. CONDUIT ONE OR MORE NOM 4 IN DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR STEEL CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE

SPACE BETWEEN CONDUITS OR TUBES SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1/2 IN. THE

ANNULAR SPACE BETWEEN THE CONDUIT OR TUBE AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. (POINT

CONTACT) TO MAX 2-3/4 IN. CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR

WALL ASSEMBLY.

CONDUIT - NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC CONDUIT OR STEEL CONDUIT.

3. FILL, VOID OR CAVITY MATERIAL*- FOAM MIN 5 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE

ANNULUS, EXTENDING 1/2 IN. ABOVE THE TOP SURFACE OF THE FLOOR OR BOTH SURFACES OF WALL AND

OVERLAPPING THE CONCRETE 1/2 IN. ON ALL SIDES OF THE OPENING.

HILTI CONSTRUCTION CHEMICALS, DIV OF

HILTI INC -- CP 620 FIRE FOAM

*BEARING THE UL CLASSIFICATION MARK

1.- DETAILS SHOWN ARE TYPICAL DETAILS. IF FIELD CONDITIONS DO NOT

MATCH REQUIREMENTS OF TYPICAL DETAILS, APPROVED ALTERNATE DETAILS

SHALL BE UTILIZED. FIELD CONDITIONS AND DIMENSIONS NEED TO BE VERIFIED

FOR COMPLIANCE WITH THE DETAILS, INCLUDING BUT NOT LIMITED TO THE

FOLLOWING:

* MINIMUM AND MAXIMUM WIDTH OF JOINTS

* TYPE AND THICKNESS OF FIRE-RATED CONSTRUCTION.

THE MINIMUM ASSEMBLY RATING OF THE FIRESTOP ASSEMBLY SHALL MEET OR

EXCEED THE HIGHEST RATING OF THE ADJACENT CONSTRUCTION.

2.- IF ALTERNATE DETAILS MATCHING THE FIELD CONDITIONS ARE NOT

AVAILABLE, MANUFACTURER'S ENGINEERING JUDGMENT DRAWINGS ARE

ACCEPTABLE. DRAWINGS SHALL FOLLOW THE INTERNATIONAL FIRESTOP

COUNCIL (IFC) GUIDELINES FOR EVALUATING FIRESTOP SYSTEMS ENGINEERING

JUDGMENTS.

3.- REFERENCES:

* 2002 UNDERWRITER'S LABORATORIES FIRE RESISTANCE DIRECTORY,

VOLUMES 1 & 2

* NFPA 101 LIFE SAFETY CODE

* NFPA 70 - NATIONAL ELECTRIC CODE

4.- FIRESTOP SYSTEM INSTALLATION MUST MEET REQUIREMENTS OF ASTM

E-814 (UL 1479) TESTED ASSEMBLIES THAT PROVIDE A FIRE RATING EQUAL TO

THAT OF CONSTRUCTION BEING PENETRATED.

5.- ALL RATED THROUGH-PENETRATION ASSEMBLIES SHALL BE PROMINENTLY

LABELED WITH THE FOLLOWING INFORMATION:

* ATTENTION: FIRE RATED ASSEMBLY

* UL SYSTEM #

* PRODUCT(S) USED

* HOURLY RATING (F-RATING)

* INSTALLATION DATE

6.- FOR OUTLET BOXES REQUIRING PROTECTION, USE ONLY WALL OPENING

PROTECTIVE MATERIALS, CATEGORY CLIV AS CLASSIFIED BY UNDERWRITER'S

LABORATORIES, FIRE RESISTANCE DIRECTORY (VOLUME 1.)

T RATING = 0-HR.

F RATING = 3-HR.

T RATING - 0 HR

F RATING - 2 HR

1. FLOOR OR WALL ASSEMBLY -- THE FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE

CONSTRUCTED OF

THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION

DESIGNS

IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:

A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO

CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND

SPACED MAX 24 IN. OC.

B. GYPSUM BOARD* -- NOM 5/8 IN. THICK GYPSUM WALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND

PARTITION DESIGN. MAX DIAM OF OPENING IS 4 IN.

2. METALLIC SLEEVE -- (OPTIONAL) -- NOM 4 IN. DIAM (OR SMALLER) SCHEDULE 40 (OR THINNER) STEEL PIPE CAST

INTO WALL ASSEMBLY WITH JOINT COMPOUND AND INSTALLED FLUSH WITH WALL SURFACES.

3. ELECTRICAL NONMETALLIC TUBING+ -- NOM 2 IN. DIAM (OR SMALLER) CORRUGATED WALL ELECTRICAL

NONMETALLIC

TUBING (ENT) CONSTRUCTED OF POLYVINYL CHLORIDE (PVC). TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES

OF WALL

ASSEMBLY. A NOM ANNULAR SPACE OF 3/4 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM.

SEE ELECTRICAL NONMETALLIC TUBING (FKHU) CATEGORY IN THE ELECTRICAL CONSTRUCTION MATERIALS

DIRECTORY FOR

NAMES OF MANUFACTURERS.

4. FILL, VOID OR CAVITY MATERIAL* -- SEALANT -- INSTALLED SYMMETRICALLY ON BOTH SIDES OF THE WALL. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH EACH END OF THE STEEL

SLEEVE AT

THE THICKNESS SHOWN IN THE TABLE BELOW:

F RATING HR T RATING HR FILL MTL DEPTH IN.

1 0 5/8

2 2 1-1/4

HILTI CONSTRUCTION CHEMICALS, DIV OF

HILTI INC -- FS-ONE SEALANT

+BEARING THE UL LISTING MARK

*BEARING THE UL CLASSIFICATION MARKING

L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT

T RATINGS - 0 AND 2 HR (SEE ITEM 4)

F RATINGS - 1 & 2 HR (SEE ITEM 4)

L RATING AT 400 F - 4 CFM/SQ FT

NOTES:

4' 2-LAMP CHAIN HUNG INDUSTRIAL FLUORESCENT FIXTURE WITH 10%

UPLIGHT.

18" HALF CYLINDER TYPE 3 DISTRIBUTION WALL MOUNT DIE CAST ALUMINUM

ALUMINUM, 4000 LUMEN LED LIGHT FIXTURE. HEAT AND IMPACT RESISTANT

2'X4' BEHAVIORAL HEALTH RECESSED LIGHT FIXTURE WITH VANDAL

RESISTANT FASTENERS. 3-LAMP, .187" PRISMATIC POLYCARBONATE IMPACT

RESISTANT LENS. (2) BALLASTS. WITH DRYWALL FLANGE.

BEHAVIORAL HEALTH UNIVERSAL MOUNT RED LED EXIT SIGN. WHITE COLOR.

BEHAVIORAL HEALTH UNIVERSAL MOUNT, DOUBLE FACED, RED LED EXIT SIGN.

WHITE COLOR.

1.- VERIFY COLOR SELECTION FOR HOUSING FINISH WITH ARCHITECT AND OWNER PRIOR TO ORDERING.

2.- FIXTURE SHALL BE VANDAL RESISTANT TYPE AND SHALL BE EQUIPPED WITH TORX HEAD FASTENERS

WITH CENTER PIN.

6" CORRECTIONAL GRADE RESISTANT RECESSED LED DOWNLIGHT. WET-

LISTED. 2000 LUMEN, WITH 0.156" PRISMATIC POLYCARBONATE LENS, FLUSH

2'X4' RECESSED VOLUMETRIC STANDARD LIGHT FIXTURE, 2-LAMP, WITH STEP

DIMMED BALLAST.

2'X4' BEHAVIORAL HEALTH RECESSED LIGHT FIXTURE WITH VANDAL

RESISTANT FASTENERS. 3-LAMP, .187" PRISMATIC POLYCARBONATE IMPACT

RESISTANT LENS. (2) BALLASTS. FOR INSTALLATION IN LAY-IN CEILING.

6" RECESSED LED DOWNLIGHT WITH SEMI-SPECULAR FINISH 2000 LUMEN

FLUSH TRIM.

RECESSED WALL MOUNTED 6"X9" 14-GAUGE WHITE SECURITY STEP LIGHT.

AMBER LED, WITH VANDAL RESISTANT FASTENERS AND .156"

POLYCARBONATE INNER AND OUTER LENS. HOUSING SHALL BE

CONTINOUSLY SEAM WELDED. AMBER LED. LIGHT LEVEL ADJUSTABLE

FROM 40% - 100% LIGHT LEVEL.

1. SENSORS AND POWER PACKS SHALL BE MADE BY A SINGLE MANUFACTURER.

2. ALL LOW VOLTAGE WIRING BETWEEN SENSORS AND POWER PACKS SHALL BE

LOW VOLTAGE CLASS 2 PLENUM RATED CABLING PER MANUFACTURER'S

RECOMMENDATIONS.

3. NUMBER AND CONFIGURATION OF SWITCHES AS INDICATED ON THE PLANS

FOR EACH ROOM. NOT ALL ROOMS WILL HAVE DUAL LEVEL SWITCHING.

4. MULTI-POLE RELAYS MAY BE USED WHERE LOCAL CIRCUITS ARE SAME

VOLTAGE.

5. THE LOCATIONS AND QUANTITIES OF SENSORS AND RELATED COMPONENTS

SHOWN ON DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE ROOMS

WHICH ARE TO BE PROVIDED WITH SENSORS. THE CONTRACTOR SHALL PROVIDE

ADDITIONAL SENSORS, RELAYS OR OTHER SYSTEM COMPONENTS IF REQUIRED

TO PROPERLY AND COMPLETELY CONTROL THE RESPECTIVE ROOM.

1/8" TEMPERED GLASS GASKETED LENS. IP66 RATED

TRIM.

2'X2' BEHAVIORAL HEALTH RECESSED LIGHT FIXTURE WITH VANDAL

RESISTANT FASTENERS. 3-LAMP, .187" PRISMATIC POLYCARBONATE IMPACT

RESISTANT LENS. (2) BALLASTS. FOR INSTALLATION IN LAY-IN CEILING.

2'X4' RECESSED VOLUMETRIC STANDARD LIGHT FIXTURE, LED, WITH 0-10V

DIMMING TO 1%.

RESISTANT FASTENERS. LED, .187" PRISMATIC POLYCARBONATE IMPACT

RESISTANT LENS. FOR INSTALLATION IN LAY-IN CEILING.

2'X4' BEHAVIORAL HEALTH RECESSED LIGHT FIXTURE WITH VANDAL

3.- COORDINATE TEMPERATURE/COLOR SELECTION FOR LED LIGHTS TO BEST MATCH TEMPERATURE/COLOR OF FLUORESCENT LAMPS USED IN PROJECT.

AFF ABOVE FINISHED FLOOR - TO BOTTOM OF ITEM UNLESS INDICATED

OTHERWISE ON DRAWINGS

CKT CIRCUIT

C CONDUIT

CM CONSTRUCTION MANAGER

DISC DISCONNECT

E EXISTING TO REMAIN

EC ELECTRICAL CONTRACTOR

EM EMERGENCY

ES EQUIPMENT SUPPLIER

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FPC FIRE PROTECTION CONTRACTOR

GC GENERAL CONTRACTOR

GND GROUND

HC HEATING CONTRACTOR

MH MOUNTING HEIGHT TO CENTERLINE OF ITEM UNLESS INDICATED

OTHERWISE ON DRAWINGS

NIC NOT IN CONTRACT

PC PLUMBING CONTRACTOR

R DEVICE TO BE REMOVED AND RELOCATED TO ANOTHER AREA

RD DEVICE RELOCATED FROM ANOTHER AREA

S SURFACE MOUNTED

SS STAINLESS STEEL

TYP TYPICAL

WG WIRE GUARD SIZED SPECIFICALLY FOR DEVICE IT IS SERVING

WP WEATHERPROOF

UNO UNLESS NOTED OTHERWISE

PLAN NOTE SYMBOL - APPLIES ONLY TO SHEET ON WHICH NOTE IS

SHOWN

DETAIL NOTE SYMBOL - APPLIES ONLY TO DETAIL ON WHICH NOTE IS

SHOWN

EQUIPMENT REFERENCE SYMBOL#

ROOM NUMBER#

DETAIL B SHOWN ON SHEET E2

B

E2

ELECTRICAL CONNECTION REQUIRED

EXIT LIGHTING FIXTURE, ARROWS AS INDICATED, CEILING

MOUNTED, CONNECT AHEAD OF LOCAL SWITCHING

EXIT LIGHTING FIXTURE, ARROWS AS INDICATED, WALL MOUNTED

AT 3" CLEAR ABOVE DOOR TRIM OR BELOW CEILING AS REQUIRED,

CONNECT AHEAD OF LOCAL SWITCHING

LIGHTING FIXTURE; CAPITAL LETTER DENOTES FIXTURE TYPE, LOWER

CASE LETTER DENOTES SWITCHING ARRANGEMENT

LIGHTING FIXTURE ON EMERGENCY CIRCUIT SPECIFIED

EACH ARROWHEAD REPRESENTS ONE COMPLETE CIRCUIT; CAPITAL

LETTER DENOTES PANEL; NUMBER DENOTES CIRCUIT

A-1&2

WIRE & CONDUIT IN WALL OR ABOVE CEILING. ALL DASH LINES

SHALL SIGNIFY WORK TO BE REMOVED.

WIRE & CONDUIT IN OR BELOW FLOOR SLAB OR BELOW GRADE

CABLE TRAY

JUNCTION BOX

20A-125V SINGLE RECEPTACLE, NEMA 5-20R (18" MH)

20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (18" MH)

GENERAL SUBSCRIPTS:

GF - GROUND FAULT CIRCUIT INTERRUPTER

WP - WEATHER RESISTANT RECEPTACLE W/ WEATHERPROOF

COVER

SPECIAL PURPOSE RECEPTACLE, REFER TO NOTE ON PLAN (18" M.H.

UNO)

20A-125V DOUBLE DUPLEX RECEPTACLE, NEMA 5-20R, (18" M.H.)

TWO-GANG ASSEMBLY

20A-125V DOUBLE DUPLEX RECEPTACLE, NEMA 5-20R, (46" M.H.)

WHERE SHOWN ABOVE COUNTER, COORDINATE HEIGHT WITH

CASEWORK CONTRACTOR

20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (46" MH), WHERE

SHOWN ABOVE COUNTER, COORDINATE HEIGHT WITH CASEWORK

CONTRACTOR

SINGLE POLE WALL SWITCH (46" MH), RATED FOR ONE HORSE

POWER.

GENERAL SUBSCRIPTS:

a - LOWERCASE LETTER DENOTES SWITCHING GROUP

2 - TWO-POLE WALL SWITCH (46" MH)

3 - THREE-WAY WALL SWITCH (46" MH)

4 - FOUR-WAY WALL SWITCH (46" MH)

M - FLUSH FRACTIONAL HORSEPOWER MOTOR STARTER WITH

NEON PILOT LIGHT, ONE-GANG ASSEMBLY (46" MH)

OS - AUTOMATIC WALL SWITCH. DUAL TECHNOLOGY WITH

20-MINUTE DELAY.

OS2 - 2 CIRCUIT AUTOMATIC WALL SWITCH. DUAL

TECHNOLOGY WITH 20-MINUTE DELAY.

RO - MOMENTARY CONTACT LOW VOLTAGE 2 HOUR OVERRIDE

SWITCH FOR AUTOMATIC LIGHTING CONTROL SYSTEM (46"

MH)

K - TAMPER RESISTANT BARREL KEY OPERATED WALL SWITCH

WP - WEATHERPROOF WALL SWITCH

GANGED SWITCH ASSEMBLY (46" MH)

GANGED SWITCH ASSEMBLY FOR MULTI-LEVEL LIGHTING

APPLICATIONS, INNER LAMP(S) SHALL BE SWITCHED SEPARATELY

FROM OUTER LAMPS, UNLESS NOTED OTHERWISE.

HEAVY DUTY DISCONNECT SWITCH, SEE EQUIPMENT SCHEDULE FOR

SOURCES/VOLTAGES AND ALL REQUIREMENTS

ELECTRIC MOTOR

CIRCUIT BREAKER PANEL (FLUSH MOUNTED)

CIRCUIT BREAKER PANEL (SURFACE MOUNTED)

MISCELLANEOUS PANEL (FLUSH MOUNTED)

MISCELLANEOUS PANEL (SURFACE MOUNTED)

CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR.

20-MINUTE DELAY. REFER TO OCCUPANCY SENSOR DETAIL

COR CONTRACTING OFFICER'S REPRESENTATIVE

120/277C1 -2 - 4100K 32W T8 LAMP C - 9'-0" AFF --

32W

T8

X1 120/277 -- - UV 2LED INTEGRAL

W2 120/277

- - 1- 4000K LED W (12'-0" MH)

LED

35W

X2 120/277 -- - UV 2LED INTEGRAL

PHOTOCELL SENSOR. INTERFACE TO THE LIGHTING CONTROL PANEL

TO PROVIDE INPUT FOR CONTROLLING RELAYS.

120/277R1 -3 - 4100K 32W T8 LAMP R 2

32W

T8

R2

W1 120/277

120/277D1 -- - R 2LED

33.6W

4000K 33.6W LED

120/277 -2 - 4100K 32W T8 LAMP R 232W

R3 120/277 -2 - 4100K 32W T8 LAMP R --32W

- - 1- AMBER LED W (1'-6" MH)LED

120/277D2 -- - R --LED

33.6W

4000K 33.6W LED

P#

P#

P#

P#

EXISTING LIGHT FIXTURE OR ELECTRICAL DEVICE TO BE REMOVED

AND/OR RELOCATED AND CIRCUITRY MADE CONTINUOUS WHERE

REQUIRED. UNO, LINE TYPE TYPICAL FOR ALL DEVICES TO BE

REMOVED AND/OR RELOCATED.

EXISTING LIGHT FIXTURE OR ELECTRICAL DEVICE TO REMAIN,

MAINTAIN EXISTING CIRCUITRY. UNO, LINE TYPE TYPICAL FOR ALL

DEVICES TO REMAIN.

GTD LIGHTING GENERATOR TRANSFER DEVICE. CONNECT VOLTAGE

SENSING LEADS AHEAD OF ALL SWITCHING.

T - TAMPER RESISTANT RECEPTACLE EQUIPPED WITH GROUND

FAULT CIRCUIT INTERRUPTER.

(46" MH)

50W

LOCAL CIRCUIT PER PLANS

HN

DUAL TECHNOLOGY

OCCUPANCY SENSOR

WALL OR CEILING

MOUNTED

SINGLE RELAY/

POWER PACK

INSIDE LAMPS

OUTSIDE LAMPS

LOCAL ROOM

SWITCHES

ROOM

LUMINAIRES

OR STEP DIM

TO ADDITIONAL

SENSORS

(IF NECESSARY)

RED (+24 VDC)

BLACK (COM)

BLUE (CTRL)

SUBSCRIPT "NL" DENOTES NIGHT LIGHT. CONNECT AHEAD OF

ALL SWITCHING.

NL NIGHT LIGHT. CONNECT AHEAD OF SWITCHING.

NAC NOTIFICATION APPLIANCE CIRCUIT

R4 120/277 -2 - 4100K 32W T8 LAMP R 232W

R5 120/277 - - 4000K 40W LED R 2,340W

R6 120/277 - - 4000K 32W LED R 332W

LEGEND LEGEND CONTINUEDLIGHTING FIXTURES

LAMP DESCRIPTION

LAMPS

D E

S

IG

N A

T

IO

N F

IX

T

U R

E

V O

LT

A

G E

FIXTURE DESCRIPTION

IN

C

A N

D E

S C

E N

T

W A

T T

S

L A

M P

F

LU

O R

E S

C E

N T

H

ID

QUANTITY

AC - AIRCRAFT CABLE

C - CHAIN

CM - CEILING MOUNT

CV - COVE

P - STEM

R - RECESSED

S - SURFACE

UC - UNDER CABINET

W - WALL

UV - UNIVERSAL

MOUNTING OPTIONS

R E

F E

R T

O N

O T

E (S

BASEMENT ELEC DEMO PLAN

E000

SHEET

NUMBER

ED100

ELECTRICAL LEGEND

FIRST FLOOR ELEC DEMO PLANED101

SECOND FLOOR ELEC DEMO PLANED102

EL100

EL101

EP100

EP101

EP101A

EP102

BASEMENT LIGHTING PLAN

FIRST FLOOR LIGHTING PLAN

FIRST FLOOR POWER PLAN

SECOND FLOOR POWER PLAN

ELECTRICAL SINGLE LINE

A.- GENERAL NOTES APPLY TO ALL SHEETS.

B.- LIGHT FIXTURES ARE SHOWN IN APPROXIMATE LOCATIONS. ALL LOCATIONS

MUST BE VERIFIED IN THE FIELD WITH ALL EXISTING CONDITIONS AND OTHER

TRADES. EXTERIOR MOUNTING HEIGHTS INDICATED ON PLANS ARE FOR

REFERENCE ONLY. COORDINATE ALL HEIGHTS AND LOCATIONS WITH ARCHITECT

PRIOR TO ROUGH-IN.

C.- ALL EMERGENCY TRANSFER DEVICES, NIGHT LIGHTS AND EXITS SHALL BE

CONNECTED TO UNSWITCHED LEGS UNLESS INDICATED OTHERWISE.

D.- FOR ALL ELECTRICAL DEVICES OR FIXTURES BEING REMOVED, RECONIFIGURE

EXISTING CIRCUITRY TO REMAINING DEVICES TO MAINTAIN CIRCUIT CONTINUITY

TO REMAINING DEVICES.

E.- COORDINATE EXACT LOCATIONS OF LIGHTING FIXTURES TO BE INSTALLED IN

MECHANICAL ROOMS WITH ALL OTHER TRADES AND EQUIPMENT.

F.- DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT

G.- ALL RECEPTACLES CIRCUITED TO "EMERGENCY SYSTEM" PANELS SHALL BE RED

IN COLOR. ALL WIRING SHALL BE MIN #10 AND INCLUDE A SEPARATE FULL SIZE

NEUTRAL FOR EACH CIRCUIT.

H.- PROVIDE A BLANK COVERPLATE FOR ANY DEVICES THAT ARE REMOVED BUT

NOT REPLACED WITH NEW.

I.- NEW CIRCUITING SHALL BE CONCEALED WITHIN WALLS AND ABOVE CEILING.

J.- ROOMS WITH OPEN CEILINGS, ALL CONDUITS SHALL BE INSTALLED PARALLEL

OR PERPENDICULAR TO WALLS. ANGLED CONDUITS WILL NOT BE PERMITTED.

CONTRACTORS SHALL FIELD COORDINATE ALL DEVICE LOCATIONS PRIOR TO

SURFACE MOUNTING EMT CONDUITS OR RACEWAY.

K.- FOR EMERGENCY CIRCUITS CALLED OUT WITH INCREASED CONDUCTOR SIZING

FOR VOLTAGE DROP, CARRY SIZE INDICATED THROUGHOUT CIRCUIT TO THE

JUNCTION BOX NEAREST THE FIXTURE INDICATED AND SPLICE #10AWG

CONDUCTORS FROM JUNCTION BOX TO FIXTURE.

L.- FOR ALL EXISTING AND NEW PANELBOARDS THAT HAVE CIRCUITS ADDED OR

REMOVED, REPLACE PANELBOARD SCHEDULE WITH A NEW DETAILED SCHEDULE

OF NEW CONDITIONS IN PANELBOARD.

M.- EXTEND AND RECONFIGURE EXISTING LIGHTNING PROTECTION SYSTEM TO

PROTECT THE NEW ADDITION.

N.- FOR ALL ELECTRICAL CIRCUITS THAT ARE REMOVED AND NOT RE-FED,

REMOVE ALL CIRCUITRY AND EXPOSED CONDUIT BACK TO THE SOURCE. IF

EXISTING CIRCUIT BREAKER IS TO REMAIN, TURN THE BREAKER TO THE OFF

POSITION AND LABEL AS "SPARE" ON THE SCHEDULE.

O.- PROVIDE ALL REQUIRED FIRE ALARM SYSTEM REPROGRAMMING FOR

REMOVAL AND ADDITION OF DEVICES TO EXISTING SYSTEM THROUGHOUT

PROJECT.

P.- ALL RECEPTACLES WITHIN AREAS OF PATIENT ACCESS SHALL BE

TAMPER-RESISTANT AND GFCI TYPE RECEPTACLES.

Q- PROVIDE DYMO LABELS FOR ALL OUTLET COVERS LISTED WITH PANEL AND

CIRCUIT NUMBERS. ALL EMERGENCY OUTLETS SHALL BE SUPPLIED RED IN COLOR.

R.- EC SHALL HARD PIPE ALL EMERGENCY CIRCUITS. NO FLEXIBLE RACEWAY SHALL

BE USED FOR EMERGENCY CIRCUITS.

S.- EC SHALL MARK/IDENTIFY LOCATIONS OF ALL DEVICES IN WALLS PRIOR TO

ROUGH-IN. THE EC IS REQUIRED TO WALK THROUGH WITH OWNER/ARCHITECT

TO VERIFY ALL DEVICE LOCATIONS AFTER INSTALLATION OF STUDS AND BEFORE

ANY CONDUIT OR BOXES ARE INSTALLED (PER ROOM TYPE). AT THIS TIME, THE

OWNER/ARCHITECT MAY RELOCATE ANY DEVICE WITHIN 6' OF ITS PROPOSED

LOCATION AT NO ADDITIONAL COST.

T.- ALL ITEMS SHOWN TO BE DEMOLISHED OR REMOVED MUST BE CAREFULLY

REMOVED AND THE OWNER GIVEN FIRST RIGHT TO REFUSAL.

U.- ALL CIRCUITS FED FROM EMERGENCY PANELS SHALL BE WIRED WITH SEPARATE

FULL SIZED NEUTRAL CONDUCTORS FOR EACH CIRCUIT.

V.- ALL SCREWS FOR FIXTURES, COVER PLATES, ETC. MUST BE TAMPER RESISTANT

TORX HEAD FASTENERS WITH CENTER PINS.

W.- ALL LIGHTING CONTROLS SHALL BE SILENT. ALL AUDIBLE FUNCTIONS OF

LIGHTING CONTROLS SHALL BE DISABLED.

ATTIC ELEC DEMO PLANED103

BASEMENT POWER PLAN

FIRST FLOOR POWER CONDUIT PLAN

EP103

EP501

ELECTRICAL PANEL SCHEDULESEP601

ATTIC POWER PLAN

PROTECTIVE DEVICE. COMPLETELY REMOVE ALL ABANDONED WIRING.

X.- MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS

PASSING THROUGH RENOVATED AREAS AND SERVICE UNDISTURBED AREAS.

E001 ELECTRICAL DETAILS

Y.- WHERE DEVICES ARE SHOWN TO BE INSTALLED ON EXISTING STUD WALLS,

ONCE DEVICES ARE INSTALLED AND CIRCUITED, THE EXISTING WALL SHALL BE

PATCHED AND REPAIRED TO MATCH EXISTING WALL.

Z.- REPAIR ALL FINISHES AND ITEMS TO MATCH EXISTING ORIGINAL CONDITION

WHENEVER WORK OF THIS CONTRACT CAUSES DAMAGE OR EXPOSES UNFINISHED

CONDITIONS (INCLUDING REMOVALS FOR DEMOLITION OF MEP COMPONENTS).

PATCH ALL SURFACES AS REQUIRED TO ACHIEVE A SMOOTH SUBSTRATE SUITABLE

TO RECEIVE NEW FINISHES (PATCH ALL NICKS, BLEMISHES, ETC. AFTER PRIME

COAT, PATCHES SHALL BE PRIMED BEFORE FIRST TOP COAT).

AA.- THE CONTRACTOR IS RESPONSIBLE TO REMOVE AND REINSTALL LAY-IN

CEILING SYSTEMS AS REQUIRED TO COMPLETE THE WORK AS SHOWN ON THE

PLANS. THE CONTRACTOR MAY REUSE THE EXISTING CEILING TILES. REUSE IS

LIMITED TO TILES NOT DAMAGED DURING REMOVAL, STORAGE OR

REINSTALLATION. ALL TILES, IN THE OPINION OF THE COR, NOT ELIGIBLE FOR

REUSE SHALL BE REPLACED. THE CONTRACTOR SHALL WALK THE PROJECT WITH

THE COR, VERIFY AND ACCEPT ALL AREAS THAT THERE IS AN INTACT CEILING PRIOR

TO THE START OF CONSTRUCTION.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

© Copyright 2017

2690 W. Dublin-Granville Road, Columbus, OH 43214

p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C :\U se rs

\th am

\D oc um en ts \1

0- B

-E le c-

C en tr al

_t ha m E

2T G

L.

rv t

32 Bulletin 47 02/14/20

BID DOCUMENTS

E000

CCTS

ELECTRICAL LEGEND

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUES IN BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

GI

R

S

S

R P

F E

O

E E

T

L

I G

S

NA

O N

R E

E

D

I

R

S

E N

E

HT

A

T

S

E OF

MACE E-50556

O

OI

MONTGOMERY E-66852

GRIFFIN E-57049

CB #47AS-BUILT

L

ENG

TH AS

R

EQU IRED

CONDUIT EXPANSION JOINT CROSSING DETAIL-

FLEXIBLE CONDUIT

NTS

CONDUIT EXPANSION JOINT CROSSING DETAIL-

EXPANSION FITTING

NTS

CONDUIT TRAPEZE MOUNTING DETAIL

NTS

CONDUIT ROOF PENETRATION DETAIL

NTS

FLOOR SLAB PENETRATION DETAIL

NTS

LUMINAIRE MOUNTING - GYPBOARD CEILING

NTS

LUMINAIRE MOUNTING - LAY-IN CEILING

NTS

DOWNLIGHT MOUNTING - GYPBOARD CEILING

NTS

DOWNLIGHT MOUNTING - LAY-IN CEILING

NTS

EXIT SIGN MOUNTING - LAY-IN CEILING

NTS

FIXTURE WHIP FROM JUNCTION

BOX (1829mm (6') LONG MAX)

CEILING MAIN BEAM

RECESSED CAN

LUMINAIRE

REFER TO

SCHEDULE.

CEILING CROSS

BEAM

WIRE TIE OR SCREW BAR

HANGER TO CROSS BEAM

TYP.

CEILING HANGER WIRE,

TYP.

LUMINAIRE SUSPENSION WIRES

REFER TO SPECIFICATION SECTION 26 51 00

LUMINAIRE

BAR HANGERS

GYPSUM BOARD

(TYP)

RECESSED CAN

LUMINAIRE

CEILING BEAM

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING

THE RECOMMENDED MOUNTING HARDWARE.

LOCKING SQUARE WASHER

& LOCKNUT

INTEGRAL

GALVANIZED

LIPPED STEEL

MOUNTING

CHANNEL

WASHER &

LOCKNUT

REFER TO PLANS FOR

QUANTITY & SIZE OF

CONDUITS

CONDUIT CLAMP. SIZE AS

REQUIRED

GENERAL NOTES:

2. FASTEN THREADED ROD TO STRUCTURE BY APPROVED METHOD PER

SPECIFICATION 26 05 33, RACEWAY AND BOXES FOR ELECTRICAL

SYSTEMS. FIELD VERIFY EXACT CONDITIONS.

3. FOR TRAPEZE INSTALLATIONS IN SEISMIC AREAS REFER TO SPECIFICATION

SECTION 13 05 41, SEISMIC RESTRAINT REQUIREMENTS FOR

NON-STRUCTURAL COMPONENTS.

FIRESTOP SEALANT

PER SECTION 07 84 00,

FIRESTOPPING

CONDUIT, TYP

FLOOR SLAB,

TYP.

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL,

TYP.

MINERAL WOOL

(FIRMLY PACKED)

STEEL EXPANSION ANCHOR,

TYP

9.52mm

SPRING

NUT, TYP

CONDUIT FITTINGJUNCTION BOX

(SIZE AS REQUIRED)

CEILING HANGER WIRE,

TYP.

LUMINAIRE SUSPENSION WIRE

REFER TO SPECIFICATION SECTION 26 51

00.

WIRE TIE OR SCREW BAR

HANGER TO

ARCHITECTURAL CEILING

GRID TYP.

ARCHITECTURAL CEILING

GRID

RECESSED CAN

LUMINAIRE

ACOUSTICAL CEILING

TILE (TYP)

LUMINAIRE

BAR HANGERS

RECESSED CAN

LUMINAIRE

ARCHITECUTRAL

CEILING GRID

FIXTURE WHIP FROM JUNCTION

BOX (1829mm (6') LONG MAX)

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND

USING RECOMMENDED MOUNTING HARDWARE

WATER CUT-OFF MASTIC

COMPATIBLE WITH ROOF

MEMBRANE

INTEGRAL GALVANIZED

LIPPED STEEL MOUNTING

CHANNEL

ROOF

ROOF MEMBRANE

STAINLESS CLAMP, TYP.

SEAL-OFF

FITTING, TYP.

CONDUIT, TYP. BATT INSULATION

STEEL

EXPANSION

ANCHOR

9.52mm (3/8")

MIN GALVANIZED

THREADED ROD,

TYP.

LOCKING SQUARE

WASHER &

LOCKNUT

CONDUIT CLAMP.

SIZE AS REQUIREDGENERAL NOTES:

1. MAINTAIN A MINIMUM CLEARANCE OF 305mm (12") ON ALL SIDES OF ROOF PENETRATION FROM

WALLS, CURBS, AND OTHER PROJECTIONS TO FACILITATE PROPER FLASHING.

2. FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT OR OVERLAPPED.

3. VERIFY ROOF & STRUCTURAL SYSTEM WITH ARCHITECT.

4. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR TO ENSURE PROPER METHODS

& MATERIALS ARE USED TO MAINTAIN ROOF WARRANTY.

EXPANSION FITTING WITH

BONDING JUMPER

SEISMIC OR EXPANSION

JOINT. FIELD VERIFY ACTUAL

CONDITIONS & LOCATIONS.

FLOOR OR ROOF STRUCTURE. FIELD

VERIFY ACTUAL CONDITIONS, TYP.

STRUCTURAL MEMBER (BEAM,

JOIST, ETC.), TYP.

STEEL EXPANSION

ANCHOR

INSULATING

BUSHING

CONDUIT, TYP.

HEAD

CONDUIT TRAPEZE

PER SD260533-03,

TYP.

914mm

SPRING NUT

BEAM CLAMP,

TYP.

JUNCTION BOX, TYP

(SIZE AS REQUIRED)

INTEGRAL GALVANIZED

LIPPED STEEL MOUNTING

CHANNEL

JUNCTION BOX (SIZE AS

REQUIRED)

CONDUIT FITTING

PROVIDE EXTRA CABLE TO MAKE

COMPLETE LOOP AROUND BOX

PERIMETER

GENERAL NOTES:

1. INSTALLATION IS ACCEPTABLE ALTERNATE TO DETAIL SD260533-01.

2. INSTALLATION IS REQUIRED FOR CONDUIT 76mm (3") AND LARGER.

(3'-0") MAX

(3/8") MAX

PROVIDE 127mm (5") OF SLACK AT MIDPOINT

BETWEEN TWO END OF FLEXIBLE GALVANIZED

STEEL CONDUIT. PROVIDE GREEN INSULATED

COPPER EQUIPMENT GROUNDING CONDUCTOR

WITH FLEXIBLE CONDUIT.

FLOOR OR ROOF STRUCTURE. FIELD

VERIFY ACTUAL CONDITIONS, TYP.

SEISMIC OR EXPANSION

JOINT. FIELD VERIFY ACTUAL

CONDITIONS & LOCATIONS.

STRUCTURAL MEMBER (BEAM,

JOIST, ETC.), TYP.

STEEL EXPANSION

ANCHOR

CONDUIT, TYP.

CONDUIT TRAPEZE

PER SD260533-03,

TYP.

914mm

(3'-0") MAX

BEAM CLAMP,

TYP.

JUNCTION BOX, TYP

(SIZE AS REQUIRED)

INTEGRAL GALVANIZED

LIPPED STEEL MOUNTING

CHANNEL

JUNCTION BOX (SIZE AS

REQUIRED)

CONDUIT FITTING

SPRING NUT

PROVIDE EXTRA CABLE TO MAKE

COMPLETE LOOP AROUND BOX

PERIMETER

GENERAL NOTE:

1. DETAIL IS APPLICABLE ONLY FOR CONDUIT SMALLER THAN 76mm (3").

LUMINAIRE MANUFACTURER'S MOUNTING

HARDWARE

REFER TO SPECIFICATION SECTION 26 51 00

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6') LONG

MAX.)

LUMINAIRE.

REFER TO

SCHEDULE

LUMINAIRE SUSPENSION

WIRES REFER TO

SPECIFICATION SECTION

26 51 00

3 TWIST MINIMUM

(TYP)

ARCHITECTURAL CEILING

GRID

LUMINAIRE.

REFER TO

SCHEDULE

ACOUSTICAL CEILING TILE

(TYP)

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND

USING THE RECOMMENDED MOUNTING HARDWARE.

LUMINAIRE.

REFER TO

SCHEDULE

DRYWALL BORDER

LUMINAIRE MANUFACTURER'S MOUNTING

HARDWARE

REFER TO SPECIFICATION SECTION 26 51 00

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6') LONG

MAX.)

LUMINAIRE.

REFER TO

SCHEDULE

LUMINAIRE SUSPENSION

WIRES REFER TO

SPECIFICATION SECTION

26 51 00

3 TWIST MINIMUM

(TYP)

GYPSUM BOARD (TYP)

CEILING CROSS BEAM

CEILING MAIN BEAM

CEILING CROSS BEAM

GYPSUM BOARD

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS

AND USING THE RECOMMENDED MOUNTING HARDWARE.

FIXTURE WHIP FROM JUNCTION BOX

(1829mm (6') LONG MAX)

HANGER WIRE AND MOUNTING CHANNEL

ATTACHED TO STRUCTURE

REFER TO SPECIFICATION SECTION

26 51 00

INTEGRAL GALVANIZED LIPPED STEEL

MOUNTING CHANNEL

WIRE TIE THROUGH

MOUNTING CHANNEL &

CROSS BEAM, TYP.

ARCHITECTURAL

CEILING GRID

ACOUSTICAL

CEILING TILE

(TYP)

ARCHITECTURAL

CEILING GRID

6.35mm (1/4") SCREW

JUNCTION BOX

LOCKING SQUARE

WASHER & NUT

ARCHITECTURAL

CEILING GRID

CEILING HANGER WIRE

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING

THE RECOMMENDED MOUNTING HARDWARE.

PREFABRICATED FORMED 1.52mm

(0.06") THICK ALUMINUM FLASHING

ROUND COLLAR WITH MIN. 76mm

(3") WIDE FLANGE. ATTACH TO

ROOF PER MANUFACTURER'S

MULTIPLE MEMBRANE STRIPPING

PLIES FEATHERED AT FIELD OF

ROOF BY ROOFING CONTRACTOR.

PRIME FLANGE BEFORE STRIPPING.

INSTRUCTIONS

PREFABRICATED RUBBER

BOOT CAP WITH GRADUATED

STEPS & WEATHER-PROOF

PRESSURE SEAL TO COLLAR

SEALANT AT PENETRATION

TO MEMBRANE JUNCTURE

BY ROOFING CONTRACTOR

CONDUIT CLAMP.

SIZE AS REQUIRED

INTEGRAL

GALVANIZED

LIPPED STEEL

MOUNTING

CHANNEL

1. INTEGRAL GALVANIZED LIPPED STEEL MOUNTING

CHANNEL LONGER THAN 915mm (36") SHALL BE INSTALLED

WITH A CENTER SUPPORT ROD.

9.52mm (3/8") MIN

GALVANIZED

THREADED ROD,

TYP.

FLUSH AGAINST CEILING

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

© Copyright 2017

2690 W. Dublin-Granville Road, Columbus, OH 43214

p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C :\U se rs

\th am

\D oc um en ts \1

0- B

-E le c-

C en tr al

_t ha m .r vt

BID DOCUMENTS

E001

CCTS

ELECTRICAL DETAILS

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUES IN BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

GI

R

S

S

R P

F E

O

E E

T

L

I G

S

NA

O N

R E

E

D

I

R

S

E N

E

HT

A

T

S

E OF

MACE E-50556

O

OI

MONTGOMERY E-66852

GRIFFIN E-57049

AS-BUILT

UPUP

ATS

J

EBS

BS

KP

BN EBN

MEP

EDP2

EDP1

26-ATS

26-MDPE

E

E

E

E

FACP

F/A NAC

E E

E

EXISTING BUILDING 26 TRANSFORMER

Storage

Stair

S2-0

Linen

Linen Storage

7 EMS Supervisor

MER

CIO

P1 Equipment

Equipment

9A

Elec Closet

4D

Toilet

4A

HAC

Recreation

2A

EMS Storage

EMS Storage

Recreation Clinic

Storage

4C

Craft

4B

Stair

S1-0

Men's Toilet

Women's Toilet

HAC

Tele

27A

Social Work Service

EMS Office

EMR

Stair

S5-0

Cooridor

Chapel

Canteen Storage

Storage

25A Toilet

23A

MER

Stair

S3-0

Employee Health Rest Area

18A

Storage

18B

Occupational Safety &

Health Manager 18C

Employee Health Exam

18D

Employee Health Phy

Extender 18E

Employee's Health

Program Support Clerk 18F

Industrial Hygenist

18G

GEMS Coordinator

18H

Safety Program Support

Specialist 18I

Employee Health

MER

Canteen Storage

Supply Room

EMS Storage

24A

Stair

S4-0

(26-C1)E

26-DP1

E

E

E

E

E

6 6 7

8 8

26-P2

26-P1

(26-ACRC1)E

PLAN NOTES

1.- EXISTING SIMPLEX 4100ES FIRE ALARM CONTROL PANEL.

2.- LOCATION OF EXISTING SCHNEIDER ELECTRIC GENERATOR NETWORK PANEL.

REFER TO TECHNOLOGY PLANS FOR WORK ASSOCIATED WITH MAINTAINING

SERVICE. NEW ATS SHALL BE TIED BACK INTO THE EXISTING SYSTEM. ALL

REQUIRED PROGRAMMING SHALL BE PROVIDED TO UPDATE SYSTEM.

3.- DISCONNECT AND REMOVE EXISTING 208V, 400A AUTOMATIC TRANSFER

SWITCH. ALL CONDUIT AND CABLE TO BE RECONFIGURED FOR INSTALLATION OF

NEW TRANSFER SWITCH IN SAME LOCATION. NEW TRANSFER SWITCH IS TO BE

INTEGRATED INTO THE EXISTING SCHNEIDER ELECTRIC GENERATOR NETWORK

SYSTEM. PROVIDE ALL REQUIRED SCHNEIDER ELECTRIC SYSTEM PROGRAMMING

TO INCORPORATE NEW OWNER PROVIDED ATS INTO SYSTEM.

4.- LOCATION OF EXISTING GENERATOR THAT IS FEEDING BUILDING 26 AND

NEIGHBORING BUILDING 27.

5.- LOCATION OF EXISTING PRIMARY DISTRIBUTION TRANSFORMER FEEDING

BUILDING 26.

6.- DISCONNECT AND REMOVE EXISTING RECEPTACLE. DEMO CIRCUITRY BACK TO

JUNCTION BOX TO BE RELOCATED.

7.- CAREFULLY REMOVE EXISTING JUNCTION BOX. JUNCTION BOX TO BE

RELOCATED TO ACCOMMODATE THE CONSTRUCTION OF THE NEW WALLS.

RECONFIGURE EXISTING CIRCUITRY AND CONDUIT ENTERING JUNCTION BOX AS

REQUIRED. REFER TO NEW WORK PLANS.

8.- DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. DEMO ASSOCIATED

CIRCUITRY BACK TO LIGHT FIXTURES REMAINING. RECONFIGURE CIRCUITRY AS

REQUIRED AS EXISTING LIGHT FIXTURES ARE SWITCHED WITHIN THEIR

RESPECTIVE ROOM. NEW LIGHT FIXTURES ARE TO BE INSTALLED WITHIN

CORRIDOR AND CIRCUITED SEPARATELY. REFER TO NEW WORK PLAN.

9.- EXISTING LIGHT FIXTURES ARE TO REMAIN. RECONFIGURE EXISTING

CIRCUITRY SO LIGHT FIXTURES ARE SWITCHED SEPARATELY. REFER TO NEW

WORK PLAN.

10.- DISCONNECT AND REMOVE EXISTING LIGHT SWITCH. DEMO CIRCUITRY BACK

TO NEXT LIVE DEVICE. CIRCUITRY AND SWITCHING OF LIGHT FIXTURES TO BE

RECONFIGURED FOR NEW ROOM LAYOUT. REFER TO NEW WORK PLAN.

11.- DISCONNECT EXISTING PUMP AND REMOVE EXISTING COMBINATION

MOTOR STARTER/DISCONNECT SWITCH FEEDING PUMP. DEMO CIRCUITRY AND

EXPOSED CONDUIT BACK TO SOURCE. COORDINATE DISCONNECTION WITH

DIVISION 23.

12.- EXISTING SCHNEIDER ELECTRIC GENERATOR NETWORK PANEL. SYSTEM IS TO

BE REPROGRAMMED AS REQUIRED TO INCORPORATE REPLACED ATS INTO

SYSTEM.

13.- NOTE NOT USED.

14.- NOTE NOT USED.

15.- EXISTING CONDENSATE PUMP TO REMAIN.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

© Copyright 2017

2690 W. Dublin-Granville Road, Columbus, OH 43214

p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C :\U se rs

\th am

\D oc um en ts \1

0- B

-E le c-

C en tr al

_t ha m .r vt

BID DOCUMENTS

ED100

CCTS

BASEMENT ELEC DEMO

PLAN

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUES IN BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

SCALE: 1/8" = 1'-0"

BASEMENT ELEC DEMO PLAN

GI

R

S

S

R P

F E

O

E E

T

L

I G

S

NA

O N

R E

E

D

I

R

S

E N

E

HT

A

T

S

E OF

MACE E-50556

O

OI

MONTGOMERY E-66852

DN

UP

UP

UP

UP

UP

UP UP

DN

JJ

J

J

J

J

J

J

J

J

J

J

J

JJ

J J J J

J

J

J J

J

J

J

J J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

L

L

E1S

1S 1N E1N

3 3 3

3 3

E

E E E E

E E

E

8 8 8 8

8 8

8 8

8 8 8 8

8 8

8 8

2 Bed Room

Storage

2 Bed Room

Storage

119 Storage

Toilet/Shower

118A

Toilet/Shower

122A

2 Bed Room

1 Bed Room

Cooridor

100F

Tub/Laundry Room

Toilet

117A Nurse Station

Storage

116A

Toilet/Shower

115A

1 Bed Room

Closet

107A

Elec Closet

HAC

Stair

S2-1

1 Bed Room

1 Bed Room

1 Bed Room

HAC Storage

Toilet/Shower

110A

Staff Locker Room

Staff Toilet

111A

Cooridor

100G

Cooridor

100H

Stair

S1-1

Physician

Break Room

Social Worker

Toilet/Shower

104A

Linen Chute

Toilet

126A

1 Bed Room

Visitor's Room

Cooridor

100D

Toilet

128A

Staff Toilet

Nurse Manager

Exam & Interview

Med Carts

Med Prep

101A

Nurse Station

Cooridor

100C

SPD Storage

Signal Closet

130 Cooridor

100A

Cooridor

100B

Clean Linen

Signal Closet

Telephone Closet

Patient Toilet

Stair

S5-1

Patient Dining Room

Kitchenette

Vestibule

Patient Lounge

Patient Telephones

2 Bed Room

1 Bed Room

Toilet/Shower

162A

Toilet/Shower

137A

2 Bed Room

2 Bed Room

Cooridor

100E

Stair

S3-1

Elec Closet

HAC

1 Bed Room

2 Bed Room

Toilet/Shower

139A Storage

Storage

2 Bed Room

Storage

Toilet/Shower

143A

2 Bed Room

Cooridor

100I

Ante Room

1 Bed Room

1 Bed Room

Ante Room

Toilet/Shower

147AStorage

148A

Soiled Utility

PA Office

Treatment Team Room

Cooridor

100J

Treatment Team Room

Social Worker

Psychiatrist

Social Worker

Social Worker

Psychiatrist

Storage

Stair

S4-1

E

E

E

E

E

6 6

E

E

E

E

E

6 6

E

E E E E

DEDUCT ALTERNATE 3

DEDUCT ALTERNATE 1

DEDUCT ALTERNATE 4

PLAN NOTES

1.- DISCONNECT AND REMOVE EXISTING PANELBOARD. DEMO CIRCUITRY AND

CONDUIT BACK TO SOURCE. REFER TO SINGLE LINE DIAGRAM FOR FURTHER

INFORMATION.

2.- EXISTING CONDUIT FEEDING THROUGH CLOSET UP TO PANELBOARD ON

FLOOR ABOVE FROM BASEMENT. CONDUIT AND CIRCUITRY TO BE REMOVED AND

DEMOED BACK TO SOURCE. PANELS ON FLOOR ABOVE ARE TO BE RE-FED.

3.- DISCONNECT AND REMOVE ALL INTERIOR ELECTRICAL DEVICES (RECEPTACLES,

LIGHT FIXTURES AND ASSOCIATED SWITCHES, FIRE ALARM DEVICES, SURFACE

RACEWAY AND BOXES, PANELS, ETC.) IN THIS AREA UNLESS NOTED OTHERWISE.

REMOVE ALL CONDUIT AND WIRE BACK TO SOURCE. REFER TO NEW WORK PLAN

FOR INSTALLATION OF NEW DEVICES.

4.- EXISTING LOCATION OF LIGHTNING PROTECTION SYSTEM DOWNRUNNER AND

GROUNDING ROD. DEMO EXISTING DOWNRUNNER AND GROUND ROD.

LIGHTNING PROTECTION SYSTEM IS TO REMAIN AND TO BE EXTENDED TO NEW

ADDITION. REFER TO NEW WORK PLANS.

5.- DISCONNECT EXISTING FLUSH MOUNTED LIGHT FIXTURE. REMOVE LIGHT

FIXTURE, CIRCUITRY, AND CONDUIT BACK TO SOURCE.

6.- EXISTING STAIRWELL LIGHT FIXTURE TO REMAIN. DEMO EXISTING CIRCUITRY

FROM EXISTING PANELBOARD. EXISTING CIRCUITRY TO BE EXTENDED TO NEW

PANELBOARD CIRCUIT AS SHOWN ON NEW WORK PLANS.

7.- DISCONNECT AND REMOVE EXISTING WATER CLOSET SENSOR IN CHASE.

DEMO CIRCUITING AND CONDUIT BACK TO SOURCE.

8.- DISCONNECT EXISTING FAN COIL UNIT. DEMO CIRCUITING AND CONDUIT

BACK TO SOURCE.

9.- DISCONNECT EXISTING CIRCUIT FEEDING THE WALL MOUNTED EXTERIOR

LIGHT FIXTURES. FIXTURES AND CONCEALED CIRCUITRY TO REMAIN. CIRCUIT IS

TO BE RE-FED FROM NEW PANELBOARD. REFER TO NEW WORK PLANS.

10.- DISCONNECT EXISTING CIRCUIT FEEDING LIGHTING IN ELEVATOR SHAFT.

CIRCUIT IS TO BE EXTENDED TO NEW PANELBOARD LOCATION. REFER TO NEW

WORK PLANS.

11.- DISCONNECT EXISTING TUB. DEMO CIRCUITRY AND CONDUIT BACK TO

SOURCE. DEMO ALL ASSOCIATED DISCONNECT SWITCHES.

12.- DISCONNECT AND REMOVE EXISTING EXIT SIGN. DEMO CIRCUITRY BACK TO

SOURCE. BACKBOX AND CONCEALED CONDUIT WITHIN EXISTING WALL TO ABOVE

ACCESSIBLE CEILING TO REMAIN FOR INSTALLATION OF NEW EXIT SIGN IN SAME

LOCATION.

13.- DEDUCT ALTERNATE 3: IF ALTERNATE 3 IS ACCEPTED, THIS SPACE IS TO

REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING

THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW

PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD

LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.

14.- DEDUCT ALTERNATE 1: IF ALTERNATE 1 IS ACCEPTED, THIS SPACE IS TO

REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING

THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW

PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD

LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.

15.- DEDUCT ALTERNATE 4: IF ALTERNATE 4 IS ACCEPTED, THIS SPACE IS TO

REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING

THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW

PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD

LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

© Copyright 2017

2690 W. Dublin-Granville Road, Columbus, OH 43214

p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C :\U se rs

\th am

\D oc um en ts \1

0- B

-E le c-

C en tr al

_t ha m .r vt

BID DOCUMENTS

ED101

CCTS

FIRST FLOOR ELEC DEMO

PLAN

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUES IN BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

SCALE: 1/8" = 1'-0"

FIRST FLOOR ELEC DEMO PLAN

GI

R

S

S

R P

F E

O

E E

T

L

I G

S

NA

O N

R E

E

D

I

R

S

E N

E

HT

A

T

S

E OF

MACE E-50556

O

OI

MONTGOMERY E-66852

GRIFFIN E-57049

AS-BUILT

rviviano Rectangle

DN

UP

DN

DN

2S

E2S

E E

E2N

2N

Bed Room

Bed Room

Bed Room

Bed Room

Toilet

217A

Storage

Storage

Toilet

220A

Corridor

200F

Congregate Bath

Congregate Shower

216A

Soiled Utility

Congregate Toilet

Stair

S2-2

Elec Closet

HVAC

Storage

Toilet

205A

Toilet

209AToilet

210A

Bed Room

Bed Room

Bed Room

Bed Room

Toilet

211A

Linen Storage

Stair

S1-2

Corridor

200K

Bed Room

Corridor

200D

Toilet

225A

Quiet Room

Linen Chute

MIT

Exam Room

Toilet

227A

Female Toilet

Sterile Supplies

Nourishment Kitchen

Med Prep

201A

Nurse Station

Physician

Corridor

200C

Elec Closet

Corridor

200B

EMS Storage

Telephone Closet

Telephone Closet

Break Room

Corridor

200A

Stair

S5-2

Toilet

256A

Staff Toilet

Toilet

231A

Day Room

Break Room

Bed Room

Bed Room

Toilet

255A

Storage

Corridor

200E

Bed Room

Nurse Manager

Bed Room

Toilet

253A Storage

HAC

Elec Closet

Stair

S3-2

Female Shower

Corridor

200I

Bed Room

Bed Room

Bed Room

Toilet

238A

Toilet

239A

Storage

Conference Room

Congregate Bath

Congregate Shower

242A

Soiled Utility

Congregate Toilet

Bed Room

Toilet

249A Toilet

248A

Bed Room

Bed Room

Bed Room

Toilet

245A

Linen Room

Corridor

200J Stair

S4-2

12.0

11.0

10.0

9.0

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

B.0

E.1

3.2

2.4

1.6

L.0 J.0

C.5

C.0 D.0C.1 C.9

F.0 G.0 G.5E.5 F.3F.4 G.3 G.8

H.9 L.1G.4 H.0 M.0

7.2

A.0 E.0

U.0

S.5

T.0S.0 S.9S.1

Q.0P.0N.0 Q.5P.2N.3M.5 N.2 V.0R.0

Q.2P.1N.5M.1

J.5H.7G.9G.2G.1E.7

13.0

10.1

9.1

8.8

7.6

7.5

L.3

E.7

E.7

G.1

G.1

G.2

G.2

G.9

G.9

H.7

H.7

J.5

J.5

L.3

L.3

M.1

M.1

N.5

N.5

P.1

P.1

Q.2

Q.2

13.0 13.0

10.1 10.1

9.1 9.1

8.8 8.8

7.6 7.6

7.5 7.5

14.0 14.0

PLAN NOTES

1.- DISCONNECT EXISTING PANELBOARD AND DEMO CIRCUITRY AND CONDUIT

BACK TO SOURCE. PANELBOARD IS TO REMAIN AND TO BE RE-FED. REFER TO

NEW WORK PLANS AND SINGLE LINE DIAGRAM FOR FURTHER INFORMATION.

2.- CAREFULLY DISCONNECT AND REMOVE EXISTING 208V, 60A, 3-POLE

DISCONNECT SWITCH FOR DRYER. EXISTING SWITCH IS TO BE RELOCATED TO

NEW WALL BEING INSTALLED AROUND DUCTWORK PASSING THROUGH.

RECONFIGURE EXISTING CIRCUITRY AS REQUIRED.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

© Copyright 2017

2690 W. Dublin-Granville Road, Columbus, OH 43214

p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C :\U se rs

\th am

\D oc um en ts \1

0- B

-E le c-

C en tr al

_t ha m .r vt

BID DOCUMENTS

ED102

CCTS

SECOND FLOOR ELEC

DEMO PLAN

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUES IN BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

SCALE: 1/8" = 1'-0"

SECOND FLOOR ELEC EXISTING PLAN

GI

R

S

S

R P

F E

O

E E

T

L

I G

S

NA

O N

R E

E

D

I

R

S

E N

E

HT

A

T

S

E OF

MACE E-50556

O

OI

MONTGOMERY E-66852

PLAN NOTES

1.- EXISTING AIR HANDLING UNIT TO REMAIN.

26-DP1A

E

(26-AHU3)E

(26-CEF2)E

(26-AHU4)E

AP

E

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

© Copyright 2017

2690 W. Dublin-Granville Road, Columbus, OH 43214

p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C :\U se rs

\th am

\D oc um en ts \1

0- B

-E le c-

C en tr al

_t ha m .r vt

BID DOCUMENTS

ED103

CCTS

ATTIC ELEC DEMO PLAN

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUES IN BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

SCALE: 1/8" = 1'-0"

ATTIC ELEC EXISTING PLAN

GI

R

S

S

R P

F E

O

E E

T

L

I G

S

NA

O N

R E

E

D

I

R

S

E N

E

HT

A

T

S

E OF

MACE E-50556

O

OI

MONTGOMERY E-66852

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1 C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1 C1

C1 C1

C1 C1

C1

C1 C1

C1

C1 C1

C1

C1 C1

C1

C1 C1

C1

C1

C1 C1 C1 C1 C1 C1

C1 C1 C1 C1 C1 C1 C1 C1

C1

C1C1

GTD

GTD GTD

GTD

GTD

GTD GTD

GTD

C1 C1 C1

R3

E

E

E

E

OS

X1

X1

OS

C1 C1 C1 C1 C1C1

C1

GTD

1S2-15

1S2-17

1N2-20

1N2-22

EL1-25

EL1-25

EL1-25

EL1-25

EL1-25

EL1-25

EL1-25 EL1-25 EL1-25

EL1-25 EL1-25

Storage

Stair

S2-0

Linen

Linen Storage

7 EMS Supervisor

MER

CIO

P1 Equipment

Equipment

9A

Elec Closet

4D

Toilet

4A

HAC

Recreation

2A

EMS Storage

EMS Storage

Recreation Clinic

Storage

4C

Craft

4B

Stair

S1-0

Men's Toilet

Women's Toilet

HAC

Tele

27A

Social Work Service

EMS Office

EMR

Stair

S5-0

Cooridor

Chapel

Canteen Storage

Storage

25A Toilet

23A

MER

Stair

S3-0

Employee Health Rest Area

18A

Storage

18B

Occupational Safety &

Health Manager 18C

Employee Health Exam

18D

Employee Health Phy

Extender 18E

Employee's Health

Program Support Clerk 18F

Industrial Hygenist

18G

GEMS Coordinator

18H

Safety Program Support

Specialist 18I

Employee Health

MER

Canteen Storage

Supply Room

EMS Storage

24A

Stair

S4-0

PIPE BASEMENT

CORRIDOR

(BASEMENT)

C32A

PLAN NOTES

1.- RECIRCUIT EXISTING LIGHT FIXTURES TO EXISTING CIRCUIT. RECONFIGURE

CIRCUITRY SO LIGHT FIXTURES ARE CONTROLLED BY NEW OCCUPANCY SENSOR.

2.- LIGHT FIXTURES SHALL BE HUNG AT 9'-0" AFF. ALL FIXTURES SHALL BE CLOSELY

COORDINATED WITH ALL DUCTWORK TO EITHER BE MOUNTED SLIGHTLY BELOW

DUCTWORK OR TO BE SHIFTED CLEAR OF DUCTWORK. NO FIXTURES SHALL BE

MOUNTED ABOVE DUCTWORK.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and Facilities Management

CONSULTANTS:

© Copyright 2017

2690 W. Dublin-Granville Road, Columbus, OH 43214

p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C :\U se rs

\th am

\D oc um en ts \1

0- B

-E le c-

C en tr al

_t ha m .r vt

BID DOCUMENTS

EL100

CCTS

BASEMENT LIGHTING PLAN

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUES IN BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

SCALE: 1/8" = 1'-0"

BASEMENT LIGHTING PLAN

GI

R

S

S

R P

F E

O

E E

T

L

I G

S

NA

O N

R E

E

D

I

R

S

E N

E

HT

A

T

S

E OF

MACE E-50556

O

OI

MONTGOMERY E-66852

DNDN

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS

OS

OS

PLAN NOTES

1.- EXTEND EXISTING STAIRWELL LIGHTING CIRCUIT TO NEW PANELBOARD

SHOWN. RECONFIGURE EXISTING CIRCUITRY AS REQUIRED.

2.- EXTEND EXISTING EXTERIOR WALL MOUNTED FIXTURE LIGHTING CIRCUIT TO

NEW PANELBOARD SHOWN. RECONFIGURE EXISTING CIRCUITRY AS REQUIRED.

3.- EXTEND EXISTING ELEVATOR LIGHTING CIRCUIT TO NEW PANELBOARD

LOCATION. RECONFIGURE ALL EXISTING CIRCUITRY AS REQUIRED.

4.- ROUTE LIGHTING CIRCUIT THROUGH LIGHTING RELAY PANEL ZONE

INDICATED.

5.- PROVIDE LOW-VOLTAGE RELAY OVERRIDE SWITCH CONTROLLING ZONES

SPECIFIED. PROVIDE ONE BUTTON PER ZONE. CLEARLY LABEL ALL BUTTONS WITH

WHAT LOAD THEY ARE CONTROLLING.

6.- PROVIDE DEVICE IN EXISTING STUD WALL. EXISTING WALL SHALL BE PATCHED

AND REPAIRED TO EXISTING CONDITION UPON INSTALLATION OF DEVICES.

7.- INSTALL NEW EXIT SIGN IN EXISTING WALL. UTILIZE EXISTING BACKBOX AND

CONCEALED CONDUIT WITHIN EXISTING WALL TO ABOVE ACCESSIBLE CEILING

FOR MOUNTING AND ROUTING CIRCUITRY.

8.- CEILING MOUNT EXIT SIGN AS CLOSE TO WALL AS POSSIBLE.

9.- DEDUCT ALTERNATE 3: IF ALTERNATE 3 IS ACCEPTED, THIS SPACE IS TO

REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING

THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW

PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD

LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.

10.- DEDUCT ALTERNATE 1: IF ALTERNATE 1 IS ACCEPTED, THIS SPACE IS TO

REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING

THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW

PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD

LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.

11.- DEDUCT ALTERNATE 4: IF ALTERNATE 4 IS ACCEPTED, THIS SPACE IS TO

REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING

THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW

PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD

LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.

12.- DEDUCT ALTERNATE 2: IF ALTERNATE 2 IS ACCEPTED, THIS SPACE IS TO BE

SHELL SPACE ONLY. NO LIGHTING OR DEVICES ARE TO BE INSTALLED WITHIN

SPACE. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.

13.- NOTE NOT IN USE.

14.- DEDUCT ALTERNATE 2: IF ALTERNATE 2 IS ACCEPTED, THIS SPACE IS TO BE

UTILIZED AS A DUAL OCCUPANCY ROOM. REARRANGE QUIET ROOM LIGHTING

TO ACCOMODATE ADDITIONAL BED. PROVIDE ONE ADDITIONAL D1 FIXTURE AND

WALL MOUNT LIGHT SWITCH FOR MOUNTING AT HEAD OF ADDITIONAL BED.

REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.

STAFF LOUNGE /

LOCKERS

CONFERENCE

ROOM

EQUIPMENT

STORAGE

TOILET

ELEC.

INTAKE ROOM

VESTIBULE

VISITOR ROOM

SHARED

WORKROOM

EXAM ROOM

PATIENT ROOM

TYPE B

PATIENT

BATHROOM TYPE

1D

128A

PATIENT ROOM

TYPE B

WAITING

HAC

LINEN VESTIBULE

LINEN CHUTE

130A

STORAGE

133A

PATIENT ROOM

TYPE B

PATIENT

BATHROOM TYPE

1B

125A

PATIENT ROOM

TYPE B

PATIENT ROOM

TYPE A

PATIENT

BATHROOM TYPE

1B

127A

PATIENT

BATHROOM TYPE

1B

124A

PATIENT

BATHROOM TYPE

1A

122A

PATIENT ROOM

TYPE A

PATIENT

BATHROOM TYPE

1B

121A

STORAGE

120A

MED ROOM

TREATMENT TEAM

ROOM

TUB ROOM

ELEC.

TOILET

CONSULT ROOM

CONSULT ROOM

NURSE STATION

ISOLATION ROOM

110A

PATIENT

BATHROOM TYPE

1D

114A

PATIENT ROOM -

TYPE B

ISOLATION ANTE

ROOM

PATIENT ROOM

TYPE A

111 PATIENT

BATHROOM

TYPE1A

109A

PATIENT

BATHROOM TYPE

1A

111A

PATIENT ROOM

TYPE A

PATIENT ROOM

TYPE A

PATIENT ROOM

TYPE A

DAY ROOM

PATIENT

BATHROOM TYPE

1A

108A

PATIENT

BATHROOM TYPE

1A

107A

PATIENT

BATHROOM TYPE

1A

170A

PATIENT ROOM

TYPE 'A'

PATIENT ROOM

TYPE 'A'

PATIENT

BATHROOM TYPE

1A

167A

PATIENT

BATHROOM TYPE

1A

168A

PATIENT ROOM

TYPE 'A

QUIET ROOM

TOILET

TOILET

TOILET

MED ROOM

100A

SOILED UTILITY

PATIENT ROOM

TYPE B

PATIENT

BATHROOM TYPE

1D

164A

ELEC.

PATIENT LAUNDRY

TREATMENT TEAM

ROOM

STORAGE

158A

MED ROOM

PATIENT

BATHROOM TYPE

1B

157A

PATIENT ROOM

TYPE A

PATIENT ROOM

TYPE A

PATIENT

BATHROOM TYPE

1A

156A

EXISTING STAIR

S3-1

SEMI-PRIVATE

PATIENT ROOM

SEMI-PRIVATE

PATIENT ROOM

EXISTING STAIR

S5-1

EXISTING STAIR

S2-1

PATIENT

BATHROOM TYPE

1C

147A

PATIENT

BATHROOM - TYPE

1C

148A

PATIENT ROOM

TYPE B

PATIENT

BATHROOM TYPE

1B

152A

PATIENT ROOM

TYPE B

PATIENT ROOM

TYPE B

PATIENT

BATHROOM TYPE

1B

154A

PATIENT ROOM

TYPE B

PATIENT ROOM

TYPE B

DIRTY LINEN

C109A

NURSE STATION

DAY ROOM

RECREATION

DINING

DIRTY LINEN

C105A

PATIENT ROOM

TYPE B

PATIENT

BATHROOM TYPE

1B

126A

PATIENT

BATHROOM 1B

138A

VISITOR ROOM

NURSE MANAGER

PATIENT ROOM

TYPE A

PATIENT

BATHROOM TYPE

1A

169A

COURTYARD

E

E E E E

E E

E

D1

D1 D1

D1

D1D1R1

D1

D1

D1

R1

R1

D1

D1

X1 X1

X1

X1

X…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .