B26 As-Built Drawings - Electrical.pdf
PDF 9 MB Posted
- Attached to
- H959--5 Year Arc Flash Survey Federal contract opportunity
- Solicitation number
- 36C25022Q1134
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25022Q1134 0002.docx | DOCX document | |
| Elect Single Line 2.pdf | ||
| Elect Single Line 1.pdf | ||
| B26 As-Built Drawings - Electrical (1-lines and Schedules).pdf | ||
| 36C25022Q1134 0001.docx | DOCX document | |
| B31 Secondary.pdf | ||
| Pages from B18 Machine Room As-builts.pdf | ||
| 36C25022Q1134.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
OS
PC
GENERAL NOTES
ELECTRICAL SHEET INDEX
FIRE-STOPPING NOTES
OCCUPANCY SENSOR NOTES
SCALE: NONE
OCCUPANCY SENSOR DETAIL #1
(NOT ALL ITEMS
MAY APPLY)
(NOT ALL ITEMS
MAY APPLY)
B1 b
B1
H1
H1 b
E
E E
E
CT
A
A
SECTION A-A
SECTION A-A
A
A
A
A
SECTION A-A
SYSTEM #C-AJ-1226
4B
SYSTEM #C-AJ-1388
4A
4B 1
SYSTEM #W-L-2075
1B
1A
L RATING AT 400 F - 4 CFM/SQ FT
L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT
1. FLOOR OR WALL ASSEMBLY MIN 4-1/2 IN. THICK REINFORCED LIGHTWEIGHT
OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED
OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAM OF OPENING IS 32 IN.
2. METALLIC SLEEVE (OPTIONAL) NOM 32 IN. DIAM (OR SMALLER) SCHEDULE 40
(OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY,
FLUSH WITH FLOOR OR WALL SURFACES.
3. THROUGH-PENETRANT ONE METALLIC PIPE OR CONDUIT TO BE INSTALLED EITHER
CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE
BETWEEN PIPE OR CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 0 IN.
(POINT CONTACT) TO MAX 1-7/8 IN. PIPE MAY BE INSTALLED WITH CONTINUOUS POINT
CONTACT. PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL
ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY BE USED:
A. STEEL PIPE NOM 30 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
B. IRON PIPE NOM 30 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
C. COPPER PIPE NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
D. COPPER TUBING NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.
E. CONDUIT NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT.
F. CONDUIT NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT).
4. FIRESTOP SYSTEM THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:
A. PACKING MATERIAL MIN 4 IN. THICKNESS OF MIN 4 PCF MINERAL WOOL
BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM.
PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM
BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED
THICKNESS OF FILL MATERIAL.
B. FILL, VOID OR CAVITY MATERIAL* -- SEALANT MIN 1/4 IN. THICKNESS
OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF
FLOOR OR WITH BOTH SURFACES OF WALL. AT THE POINT OR CONTINUOUS
CONTACT LOCATIONS BETWEEN PIPE AND CONCRETE, A MIN 1/4 IN. DIAM
BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE CONCRETE/PIPE INTERFACE
ON THE TOP SURFACE OF FLOOR AND ON BOTH SURFACES OF WALL.
HILTI CONSTRUCTION CHEMICALS, DIV OF
HILTI INC - FS-ONE SEALANT
*BEARING THE UL CLASSIFICATION MARKING
1. FLOOR OR WALL ASSEMBLY MIN 4-1/2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE
BLOCKS*. MAX AREA OF OPENING 224 SQ IN. WITH MAX DIMENSION OF 32 IN.
SEE CONCRETE BLOCKS (CAZT) IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS.
2. CONDUIT ONE OR MORE NOM 4 IN DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR STEEL CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE
SPACE BETWEEN CONDUITS OR TUBES SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1/2 IN. THE
ANNULAR SPACE BETWEEN THE CONDUIT OR TUBE AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. (POINT
CONTACT) TO MAX 2-3/4 IN. CONDUIT OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR
WALL ASSEMBLY.
CONDUIT - NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC CONDUIT OR STEEL CONDUIT.
3. FILL, VOID OR CAVITY MATERIAL*- FOAM MIN 5 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE
ANNULUS, EXTENDING 1/2 IN. ABOVE THE TOP SURFACE OF THE FLOOR OR BOTH SURFACES OF WALL AND
OVERLAPPING THE CONCRETE 1/2 IN. ON ALL SIDES OF THE OPENING.
HILTI CONSTRUCTION CHEMICALS, DIV OF
HILTI INC -- CP 620 FIRE FOAM
*BEARING THE UL CLASSIFICATION MARK
1.- DETAILS SHOWN ARE TYPICAL DETAILS. IF FIELD CONDITIONS DO NOT
MATCH REQUIREMENTS OF TYPICAL DETAILS, APPROVED ALTERNATE DETAILS
SHALL BE UTILIZED. FIELD CONDITIONS AND DIMENSIONS NEED TO BE VERIFIED
FOR COMPLIANCE WITH THE DETAILS, INCLUDING BUT NOT LIMITED TO THE
FOLLOWING:
* MINIMUM AND MAXIMUM WIDTH OF JOINTS
* TYPE AND THICKNESS OF FIRE-RATED CONSTRUCTION.
THE MINIMUM ASSEMBLY RATING OF THE FIRESTOP ASSEMBLY SHALL MEET OR
EXCEED THE HIGHEST RATING OF THE ADJACENT CONSTRUCTION.
2.- IF ALTERNATE DETAILS MATCHING THE FIELD CONDITIONS ARE NOT
AVAILABLE, MANUFACTURER'S ENGINEERING JUDGMENT DRAWINGS ARE
ACCEPTABLE. DRAWINGS SHALL FOLLOW THE INTERNATIONAL FIRESTOP
COUNCIL (IFC) GUIDELINES FOR EVALUATING FIRESTOP SYSTEMS ENGINEERING
JUDGMENTS.
3.- REFERENCES:
* 2002 UNDERWRITER'S LABORATORIES FIRE RESISTANCE DIRECTORY,
VOLUMES 1 & 2
* NFPA 101 LIFE SAFETY CODE
* NFPA 70 - NATIONAL ELECTRIC CODE
4.- FIRESTOP SYSTEM INSTALLATION MUST MEET REQUIREMENTS OF ASTM
E-814 (UL 1479) TESTED ASSEMBLIES THAT PROVIDE A FIRE RATING EQUAL TO
THAT OF CONSTRUCTION BEING PENETRATED.
5.- ALL RATED THROUGH-PENETRATION ASSEMBLIES SHALL BE PROMINENTLY
LABELED WITH THE FOLLOWING INFORMATION:
* ATTENTION: FIRE RATED ASSEMBLY
* UL SYSTEM #
* PRODUCT(S) USED
* HOURLY RATING (F-RATING)
* INSTALLATION DATE
6.- FOR OUTLET BOXES REQUIRING PROTECTION, USE ONLY WALL OPENING
PROTECTIVE MATERIALS, CATEGORY CLIV AS CLASSIFIED BY UNDERWRITER'S
LABORATORIES, FIRE RESISTANCE DIRECTORY (VOLUME 1.)
T RATING = 0-HR.
F RATING = 3-HR.
T RATING - 0 HR
F RATING - 2 HR
1. FLOOR OR WALL ASSEMBLY -- THE FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE
CONSTRUCTED OF
THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION
DESIGNS
IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO
CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND
SPACED MAX 24 IN. OC.
B. GYPSUM BOARD* -- NOM 5/8 IN. THICK GYPSUM WALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND
PARTITION DESIGN. MAX DIAM OF OPENING IS 4 IN.
2. METALLIC SLEEVE -- (OPTIONAL) -- NOM 4 IN. DIAM (OR SMALLER) SCHEDULE 40 (OR THINNER) STEEL PIPE CAST
INTO WALL ASSEMBLY WITH JOINT COMPOUND AND INSTALLED FLUSH WITH WALL SURFACES.
3. ELECTRICAL NONMETALLIC TUBING+ -- NOM 2 IN. DIAM (OR SMALLER) CORRUGATED WALL ELECTRICAL
NONMETALLIC
TUBING (ENT) CONSTRUCTED OF POLYVINYL CHLORIDE (PVC). TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES
OF WALL
ASSEMBLY. A NOM ANNULAR SPACE OF 3/4 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM.
SEE ELECTRICAL NONMETALLIC TUBING (FKHU) CATEGORY IN THE ELECTRICAL CONSTRUCTION MATERIALS
DIRECTORY FOR
NAMES OF MANUFACTURERS.
4. FILL, VOID OR CAVITY MATERIAL* -- SEALANT -- INSTALLED SYMMETRICALLY ON BOTH SIDES OF THE WALL. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH EACH END OF THE STEEL
SLEEVE AT
THE THICKNESS SHOWN IN THE TABLE BELOW:
F RATING HR T RATING HR FILL MTL DEPTH IN.
1 0 5/8
2 2 1-1/4
HILTI CONSTRUCTION CHEMICALS, DIV OF
HILTI INC -- FS-ONE SEALANT
+BEARING THE UL LISTING MARK
*BEARING THE UL CLASSIFICATION MARKING
L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT
T RATINGS - 0 AND 2 HR (SEE ITEM 4)
F RATINGS - 1 & 2 HR (SEE ITEM 4)
L RATING AT 400 F - 4 CFM/SQ FT
NOTES:
4' 2-LAMP CHAIN HUNG INDUSTRIAL FLUORESCENT FIXTURE WITH 10%
UPLIGHT.
18" HALF CYLINDER TYPE 3 DISTRIBUTION WALL MOUNT DIE CAST ALUMINUM
ALUMINUM, 4000 LUMEN LED LIGHT FIXTURE. HEAT AND IMPACT RESISTANT
2'X4' BEHAVIORAL HEALTH RECESSED LIGHT FIXTURE WITH VANDAL
RESISTANT FASTENERS. 3-LAMP, .187" PRISMATIC POLYCARBONATE IMPACT
RESISTANT LENS. (2) BALLASTS. WITH DRYWALL FLANGE.
BEHAVIORAL HEALTH UNIVERSAL MOUNT RED LED EXIT SIGN. WHITE COLOR.
BEHAVIORAL HEALTH UNIVERSAL MOUNT, DOUBLE FACED, RED LED EXIT SIGN.
WHITE COLOR.
1.- VERIFY COLOR SELECTION FOR HOUSING FINISH WITH ARCHITECT AND OWNER PRIOR TO ORDERING.
2.- FIXTURE SHALL BE VANDAL RESISTANT TYPE AND SHALL BE EQUIPPED WITH TORX HEAD FASTENERS
WITH CENTER PIN.
6" CORRECTIONAL GRADE RESISTANT RECESSED LED DOWNLIGHT. WET-
LISTED. 2000 LUMEN, WITH 0.156" PRISMATIC POLYCARBONATE LENS, FLUSH
2'X4' RECESSED VOLUMETRIC STANDARD LIGHT FIXTURE, 2-LAMP, WITH STEP
DIMMED BALLAST.
2'X4' BEHAVIORAL HEALTH RECESSED LIGHT FIXTURE WITH VANDAL
RESISTANT FASTENERS. 3-LAMP, .187" PRISMATIC POLYCARBONATE IMPACT
RESISTANT LENS. (2) BALLASTS. FOR INSTALLATION IN LAY-IN CEILING.
6" RECESSED LED DOWNLIGHT WITH SEMI-SPECULAR FINISH 2000 LUMEN
FLUSH TRIM.
RECESSED WALL MOUNTED 6"X9" 14-GAUGE WHITE SECURITY STEP LIGHT.
AMBER LED, WITH VANDAL RESISTANT FASTENERS AND .156"
POLYCARBONATE INNER AND OUTER LENS. HOUSING SHALL BE
CONTINOUSLY SEAM WELDED. AMBER LED. LIGHT LEVEL ADJUSTABLE
FROM 40% - 100% LIGHT LEVEL.
1. SENSORS AND POWER PACKS SHALL BE MADE BY A SINGLE MANUFACTURER.
2. ALL LOW VOLTAGE WIRING BETWEEN SENSORS AND POWER PACKS SHALL BE
LOW VOLTAGE CLASS 2 PLENUM RATED CABLING PER MANUFACTURER'S
RECOMMENDATIONS.
3. NUMBER AND CONFIGURATION OF SWITCHES AS INDICATED ON THE PLANS
FOR EACH ROOM. NOT ALL ROOMS WILL HAVE DUAL LEVEL SWITCHING.
4. MULTI-POLE RELAYS MAY BE USED WHERE LOCAL CIRCUITS ARE SAME
VOLTAGE.
5. THE LOCATIONS AND QUANTITIES OF SENSORS AND RELATED COMPONENTS
SHOWN ON DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE ROOMS
WHICH ARE TO BE PROVIDED WITH SENSORS. THE CONTRACTOR SHALL PROVIDE
ADDITIONAL SENSORS, RELAYS OR OTHER SYSTEM COMPONENTS IF REQUIRED
TO PROPERLY AND COMPLETELY CONTROL THE RESPECTIVE ROOM.
1/8" TEMPERED GLASS GASKETED LENS. IP66 RATED
TRIM.
2'X2' BEHAVIORAL HEALTH RECESSED LIGHT FIXTURE WITH VANDAL
RESISTANT FASTENERS. 3-LAMP, .187" PRISMATIC POLYCARBONATE IMPACT
RESISTANT LENS. (2) BALLASTS. FOR INSTALLATION IN LAY-IN CEILING.
2'X4' RECESSED VOLUMETRIC STANDARD LIGHT FIXTURE, LED, WITH 0-10V
DIMMING TO 1%.
RESISTANT FASTENERS. LED, .187" PRISMATIC POLYCARBONATE IMPACT
RESISTANT LENS. FOR INSTALLATION IN LAY-IN CEILING.
2'X4' BEHAVIORAL HEALTH RECESSED LIGHT FIXTURE WITH VANDAL
3.- COORDINATE TEMPERATURE/COLOR SELECTION FOR LED LIGHTS TO BEST MATCH TEMPERATURE/COLOR OF FLUORESCENT LAMPS USED IN PROJECT.
AFF ABOVE FINISHED FLOOR - TO BOTTOM OF ITEM UNLESS INDICATED
OTHERWISE ON DRAWINGS
CKT CIRCUIT
C CONDUIT
CM CONSTRUCTION MANAGER
DISC DISCONNECT
E EXISTING TO REMAIN
EC ELECTRICAL CONTRACTOR
EM EMERGENCY
ES EQUIPMENT SUPPLIER
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FPC FIRE PROTECTION CONTRACTOR
GC GENERAL CONTRACTOR
GND GROUND
HC HEATING CONTRACTOR
MH MOUNTING HEIGHT TO CENTERLINE OF ITEM UNLESS INDICATED
OTHERWISE ON DRAWINGS
NIC NOT IN CONTRACT
PC PLUMBING CONTRACTOR
R DEVICE TO BE REMOVED AND RELOCATED TO ANOTHER AREA
RD DEVICE RELOCATED FROM ANOTHER AREA
S SURFACE MOUNTED
SS STAINLESS STEEL
TYP TYPICAL
WG WIRE GUARD SIZED SPECIFICALLY FOR DEVICE IT IS SERVING
WP WEATHERPROOF
UNO UNLESS NOTED OTHERWISE
PLAN NOTE SYMBOL - APPLIES ONLY TO SHEET ON WHICH NOTE IS
SHOWN
DETAIL NOTE SYMBOL - APPLIES ONLY TO DETAIL ON WHICH NOTE IS
SHOWN
EQUIPMENT REFERENCE SYMBOL#
ROOM NUMBER#
DETAIL B SHOWN ON SHEET E2
B
E2
ELECTRICAL CONNECTION REQUIRED
EXIT LIGHTING FIXTURE, ARROWS AS INDICATED, CEILING
MOUNTED, CONNECT AHEAD OF LOCAL SWITCHING
EXIT LIGHTING FIXTURE, ARROWS AS INDICATED, WALL MOUNTED
AT 3" CLEAR ABOVE DOOR TRIM OR BELOW CEILING AS REQUIRED,
CONNECT AHEAD OF LOCAL SWITCHING
LIGHTING FIXTURE; CAPITAL LETTER DENOTES FIXTURE TYPE, LOWER
CASE LETTER DENOTES SWITCHING ARRANGEMENT
LIGHTING FIXTURE ON EMERGENCY CIRCUIT SPECIFIED
EACH ARROWHEAD REPRESENTS ONE COMPLETE CIRCUIT; CAPITAL
LETTER DENOTES PANEL; NUMBER DENOTES CIRCUIT
A-1&2
WIRE & CONDUIT IN WALL OR ABOVE CEILING. ALL DASH LINES
SHALL SIGNIFY WORK TO BE REMOVED.
WIRE & CONDUIT IN OR BELOW FLOOR SLAB OR BELOW GRADE
CABLE TRAY
JUNCTION BOX
20A-125V SINGLE RECEPTACLE, NEMA 5-20R (18" MH)
20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (18" MH)
GENERAL SUBSCRIPTS:
GF - GROUND FAULT CIRCUIT INTERRUPTER
WP - WEATHER RESISTANT RECEPTACLE W/ WEATHERPROOF
COVER
SPECIAL PURPOSE RECEPTACLE, REFER TO NOTE ON PLAN (18" M.H.
UNO)
20A-125V DOUBLE DUPLEX RECEPTACLE, NEMA 5-20R, (18" M.H.)
TWO-GANG ASSEMBLY
20A-125V DOUBLE DUPLEX RECEPTACLE, NEMA 5-20R, (46" M.H.)
WHERE SHOWN ABOVE COUNTER, COORDINATE HEIGHT WITH
CASEWORK CONTRACTOR
20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (46" MH), WHERE
SHOWN ABOVE COUNTER, COORDINATE HEIGHT WITH CASEWORK
CONTRACTOR
SINGLE POLE WALL SWITCH (46" MH), RATED FOR ONE HORSE
POWER.
GENERAL SUBSCRIPTS:
a - LOWERCASE LETTER DENOTES SWITCHING GROUP
2 - TWO-POLE WALL SWITCH (46" MH)
3 - THREE-WAY WALL SWITCH (46" MH)
4 - FOUR-WAY WALL SWITCH (46" MH)
M - FLUSH FRACTIONAL HORSEPOWER MOTOR STARTER WITH
NEON PILOT LIGHT, ONE-GANG ASSEMBLY (46" MH)
OS - AUTOMATIC WALL SWITCH. DUAL TECHNOLOGY WITH
20-MINUTE DELAY.
OS2 - 2 CIRCUIT AUTOMATIC WALL SWITCH. DUAL
TECHNOLOGY WITH 20-MINUTE DELAY.
RO - MOMENTARY CONTACT LOW VOLTAGE 2 HOUR OVERRIDE
SWITCH FOR AUTOMATIC LIGHTING CONTROL SYSTEM (46"
MH)
K - TAMPER RESISTANT BARREL KEY OPERATED WALL SWITCH
WP - WEATHERPROOF WALL SWITCH
GANGED SWITCH ASSEMBLY (46" MH)
GANGED SWITCH ASSEMBLY FOR MULTI-LEVEL LIGHTING
APPLICATIONS, INNER LAMP(S) SHALL BE SWITCHED SEPARATELY
FROM OUTER LAMPS, UNLESS NOTED OTHERWISE.
HEAVY DUTY DISCONNECT SWITCH, SEE EQUIPMENT SCHEDULE FOR
SOURCES/VOLTAGES AND ALL REQUIREMENTS
ELECTRIC MOTOR
CIRCUIT BREAKER PANEL (FLUSH MOUNTED)
CIRCUIT BREAKER PANEL (SURFACE MOUNTED)
MISCELLANEOUS PANEL (FLUSH MOUNTED)
MISCELLANEOUS PANEL (SURFACE MOUNTED)
CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR.
20-MINUTE DELAY. REFER TO OCCUPANCY SENSOR DETAIL
COR CONTRACTING OFFICER'S REPRESENTATIVE
120/277C1 -2 - 4100K 32W T8 LAMP C - 9'-0" AFF --
32W
T8
X1 120/277 -- - UV 2LED INTEGRAL
W2 120/277
- - 1- 4000K LED W (12'-0" MH)
LED
35W
X2 120/277 -- - UV 2LED INTEGRAL
PHOTOCELL SENSOR. INTERFACE TO THE LIGHTING CONTROL PANEL
TO PROVIDE INPUT FOR CONTROLLING RELAYS.
120/277R1 -3 - 4100K 32W T8 LAMP R 2
32W
T8
R2
W1 120/277
120/277D1 -- - R 2LED
33.6W
4000K 33.6W LED
120/277 -2 - 4100K 32W T8 LAMP R 232W
R3 120/277 -2 - 4100K 32W T8 LAMP R --32W
- - 1- AMBER LED W (1'-6" MH)LED
120/277D2 -- - R --LED
33.6W
4000K 33.6W LED
P#
P#
P#
P#
EXISTING LIGHT FIXTURE OR ELECTRICAL DEVICE TO BE REMOVED
AND/OR RELOCATED AND CIRCUITRY MADE CONTINUOUS WHERE
REQUIRED. UNO, LINE TYPE TYPICAL FOR ALL DEVICES TO BE
REMOVED AND/OR RELOCATED.
EXISTING LIGHT FIXTURE OR ELECTRICAL DEVICE TO REMAIN,
MAINTAIN EXISTING CIRCUITRY. UNO, LINE TYPE TYPICAL FOR ALL
DEVICES TO REMAIN.
GTD LIGHTING GENERATOR TRANSFER DEVICE. CONNECT VOLTAGE
SENSING LEADS AHEAD OF ALL SWITCHING.
T - TAMPER RESISTANT RECEPTACLE EQUIPPED WITH GROUND
FAULT CIRCUIT INTERRUPTER.
(46" MH)
50W
LOCAL CIRCUIT PER PLANS
HN
DUAL TECHNOLOGY
OCCUPANCY SENSOR
WALL OR CEILING
MOUNTED
SINGLE RELAY/
POWER PACK
INSIDE LAMPS
OUTSIDE LAMPS
LOCAL ROOM
SWITCHES
ROOM
LUMINAIRES
OR STEP DIM
TO ADDITIONAL
SENSORS
(IF NECESSARY)
RED (+24 VDC)
BLACK (COM)
BLUE (CTRL)
SUBSCRIPT "NL" DENOTES NIGHT LIGHT. CONNECT AHEAD OF
ALL SWITCHING.
NL NIGHT LIGHT. CONNECT AHEAD OF SWITCHING.
NAC NOTIFICATION APPLIANCE CIRCUIT
R4 120/277 -2 - 4100K 32W T8 LAMP R 232W
R5 120/277 - - 4000K 40W LED R 2,340W
R6 120/277 - - 4000K 32W LED R 332W
LEGEND LEGEND CONTINUEDLIGHTING FIXTURES
LAMP DESCRIPTION
LAMPS
D E
S
IG
N A
T
IO
N F
IX
T
U R
E
V O
LT
A
G E
FIXTURE DESCRIPTION
IN
C
A N
D E
S C
E N
T
W A
T T
S
L A
M P
F
LU
O R
E S
C E
N T
H
ID
QUANTITY
AC - AIRCRAFT CABLE
C - CHAIN
CM - CEILING MOUNT
CV - COVE
P - STEM
R - RECESSED
S - SURFACE
UC - UNDER CABINET
W - WALL
UV - UNIVERSAL
MOUNTING OPTIONS
R E
F E
R T
O N
O T
E (S
BASEMENT ELEC DEMO PLAN
E000
SHEET
NUMBER
ED100
ELECTRICAL LEGEND
FIRST FLOOR ELEC DEMO PLANED101
SECOND FLOOR ELEC DEMO PLANED102
EL100
EL101
EP100
EP101
EP101A
EP102
BASEMENT LIGHTING PLAN
FIRST FLOOR LIGHTING PLAN
FIRST FLOOR POWER PLAN
SECOND FLOOR POWER PLAN
ELECTRICAL SINGLE LINE
A.- GENERAL NOTES APPLY TO ALL SHEETS.
B.- LIGHT FIXTURES ARE SHOWN IN APPROXIMATE LOCATIONS. ALL LOCATIONS
MUST BE VERIFIED IN THE FIELD WITH ALL EXISTING CONDITIONS AND OTHER
TRADES. EXTERIOR MOUNTING HEIGHTS INDICATED ON PLANS ARE FOR
REFERENCE ONLY. COORDINATE ALL HEIGHTS AND LOCATIONS WITH ARCHITECT
PRIOR TO ROUGH-IN.
C.- ALL EMERGENCY TRANSFER DEVICES, NIGHT LIGHTS AND EXITS SHALL BE
CONNECTED TO UNSWITCHED LEGS UNLESS INDICATED OTHERWISE.
D.- FOR ALL ELECTRICAL DEVICES OR FIXTURES BEING REMOVED, RECONIFIGURE
EXISTING CIRCUITRY TO REMAINING DEVICES TO MAINTAIN CIRCUIT CONTINUITY
TO REMAINING DEVICES.
E.- COORDINATE EXACT LOCATIONS OF LIGHTING FIXTURES TO BE INSTALLED IN
MECHANICAL ROOMS WITH ALL OTHER TRADES AND EQUIPMENT.
F.- DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT
G.- ALL RECEPTACLES CIRCUITED TO "EMERGENCY SYSTEM" PANELS SHALL BE RED
IN COLOR. ALL WIRING SHALL BE MIN #10 AND INCLUDE A SEPARATE FULL SIZE
NEUTRAL FOR EACH CIRCUIT.
H.- PROVIDE A BLANK COVERPLATE FOR ANY DEVICES THAT ARE REMOVED BUT
NOT REPLACED WITH NEW.
I.- NEW CIRCUITING SHALL BE CONCEALED WITHIN WALLS AND ABOVE CEILING.
J.- ROOMS WITH OPEN CEILINGS, ALL CONDUITS SHALL BE INSTALLED PARALLEL
OR PERPENDICULAR TO WALLS. ANGLED CONDUITS WILL NOT BE PERMITTED.
CONTRACTORS SHALL FIELD COORDINATE ALL DEVICE LOCATIONS PRIOR TO
SURFACE MOUNTING EMT CONDUITS OR RACEWAY.
K.- FOR EMERGENCY CIRCUITS CALLED OUT WITH INCREASED CONDUCTOR SIZING
FOR VOLTAGE DROP, CARRY SIZE INDICATED THROUGHOUT CIRCUIT TO THE
JUNCTION BOX NEAREST THE FIXTURE INDICATED AND SPLICE #10AWG
CONDUCTORS FROM JUNCTION BOX TO FIXTURE.
L.- FOR ALL EXISTING AND NEW PANELBOARDS THAT HAVE CIRCUITS ADDED OR
REMOVED, REPLACE PANELBOARD SCHEDULE WITH A NEW DETAILED SCHEDULE
OF NEW CONDITIONS IN PANELBOARD.
M.- EXTEND AND RECONFIGURE EXISTING LIGHTNING PROTECTION SYSTEM TO
PROTECT THE NEW ADDITION.
N.- FOR ALL ELECTRICAL CIRCUITS THAT ARE REMOVED AND NOT RE-FED,
REMOVE ALL CIRCUITRY AND EXPOSED CONDUIT BACK TO THE SOURCE. IF
EXISTING CIRCUIT BREAKER IS TO REMAIN, TURN THE BREAKER TO THE OFF
POSITION AND LABEL AS "SPARE" ON THE SCHEDULE.
O.- PROVIDE ALL REQUIRED FIRE ALARM SYSTEM REPROGRAMMING FOR
REMOVAL AND ADDITION OF DEVICES TO EXISTING SYSTEM THROUGHOUT
PROJECT.
P.- ALL RECEPTACLES WITHIN AREAS OF PATIENT ACCESS SHALL BE
TAMPER-RESISTANT AND GFCI TYPE RECEPTACLES.
Q- PROVIDE DYMO LABELS FOR ALL OUTLET COVERS LISTED WITH PANEL AND
CIRCUIT NUMBERS. ALL EMERGENCY OUTLETS SHALL BE SUPPLIED RED IN COLOR.
R.- EC SHALL HARD PIPE ALL EMERGENCY CIRCUITS. NO FLEXIBLE RACEWAY SHALL
BE USED FOR EMERGENCY CIRCUITS.
S.- EC SHALL MARK/IDENTIFY LOCATIONS OF ALL DEVICES IN WALLS PRIOR TO
ROUGH-IN. THE EC IS REQUIRED TO WALK THROUGH WITH OWNER/ARCHITECT
TO VERIFY ALL DEVICE LOCATIONS AFTER INSTALLATION OF STUDS AND BEFORE
ANY CONDUIT OR BOXES ARE INSTALLED (PER ROOM TYPE). AT THIS TIME, THE
OWNER/ARCHITECT MAY RELOCATE ANY DEVICE WITHIN 6' OF ITS PROPOSED
LOCATION AT NO ADDITIONAL COST.
T.- ALL ITEMS SHOWN TO BE DEMOLISHED OR REMOVED MUST BE CAREFULLY
REMOVED AND THE OWNER GIVEN FIRST RIGHT TO REFUSAL.
U.- ALL CIRCUITS FED FROM EMERGENCY PANELS SHALL BE WIRED WITH SEPARATE
FULL SIZED NEUTRAL CONDUCTORS FOR EACH CIRCUIT.
V.- ALL SCREWS FOR FIXTURES, COVER PLATES, ETC. MUST BE TAMPER RESISTANT
TORX HEAD FASTENERS WITH CENTER PINS.
W.- ALL LIGHTING CONTROLS SHALL BE SILENT. ALL AUDIBLE FUNCTIONS OF
LIGHTING CONTROLS SHALL BE DISABLED.
ATTIC ELEC DEMO PLANED103
BASEMENT POWER PLAN
FIRST FLOOR POWER CONDUIT PLAN
EP103
EP501
ELECTRICAL PANEL SCHEDULESEP601
ATTIC POWER PLAN
PROTECTIVE DEVICE. COMPLETELY REMOVE ALL ABANDONED WIRING.
X.- MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS
PASSING THROUGH RENOVATED AREAS AND SERVICE UNDISTURBED AREAS.
E001 ELECTRICAL DETAILS
Y.- WHERE DEVICES ARE SHOWN TO BE INSTALLED ON EXISTING STUD WALLS,
ONCE DEVICES ARE INSTALLED AND CIRCUITED, THE EXISTING WALL SHALL BE
PATCHED AND REPAIRED TO MATCH EXISTING WALL.
Z.- REPAIR ALL FINISHES AND ITEMS TO MATCH EXISTING ORIGINAL CONDITION
WHENEVER WORK OF THIS CONTRACT CAUSES DAMAGE OR EXPOSES UNFINISHED
CONDITIONS (INCLUDING REMOVALS FOR DEMOLITION OF MEP COMPONENTS).
PATCH ALL SURFACES AS REQUIRED TO ACHIEVE A SMOOTH SUBSTRATE SUITABLE
TO RECEIVE NEW FINISHES (PATCH ALL NICKS, BLEMISHES, ETC. AFTER PRIME
COAT, PATCHES SHALL BE PRIMED BEFORE FIRST TOP COAT).
AA.- THE CONTRACTOR IS RESPONSIBLE TO REMOVE AND REINSTALL LAY-IN
CEILING SYSTEMS AS REQUIRED TO COMPLETE THE WORK AS SHOWN ON THE
PLANS. THE CONTRACTOR MAY REUSE THE EXISTING CEILING TILES. REUSE IS
LIMITED TO TILES NOT DAMAGED DURING REMOVAL, STORAGE OR
REINSTALLATION. ALL TILES, IN THE OPINION OF THE COR, NOT ELIGIBLE FOR
REUSE SHALL BE REPLACED. THE CONTRACTOR SHALL WALK THE PROJECT WITH
THE COR, VERIFY AND ACCEPT ALL AREAS THAT THERE IS AN INTACT CEILING PRIOR
TO THE START OF CONSTRUCTION.
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHILLICOTHE VA MEDICAL CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
© Copyright 2017
2690 W. Dublin-Granville Road, Columbus, OH 43214
p. 614.267.6603 www.DesignLeveLarchitecture.com
DesignLeveL planning interior design architecture
C :\U se rs
\th am
\D oc um en ts \1
0- B
-E le c-
C en tr al
_t ha m E
2T G
L.
rv t
32 Bulletin 47 02/14/20
BID DOCUMENTS
E000
CCTS
ELECTRICAL LEGEND
5/22/2017
538-115CORRECT PRIVACY/
SAFETY/ENVIRONMENTAL
ISSUES IN BUILDING 26
855 Grandview Avenue, 3rd Floor Columbus, OH 43215
Phone: (614) 443-1178 Fax: (614) 443-1594
Email: dynamix@dynamix-ltd.com
Facility Engineering Consultants
Engineering Ltd.
DEL # 140120
GI
R
S
S
R P
F E
O
E E
T
L
I G
S
NA
O N
R E
E
D
I
R
S
E N
E
HT
A
T
S
E OF
MACE E-50556
O
OI
MONTGOMERY E-66852
GRIFFIN E-57049
CB #47AS-BUILT
L
ENG
TH AS
R
EQU IRED
CONDUIT EXPANSION JOINT CROSSING DETAIL-
FLEXIBLE CONDUIT
NTS
CONDUIT EXPANSION JOINT CROSSING DETAIL-
EXPANSION FITTING
NTS
CONDUIT TRAPEZE MOUNTING DETAIL
NTS
CONDUIT ROOF PENETRATION DETAIL
NTS
FLOOR SLAB PENETRATION DETAIL
NTS
LUMINAIRE MOUNTING - GYPBOARD CEILING
NTS
LUMINAIRE MOUNTING - LAY-IN CEILING
NTS
DOWNLIGHT MOUNTING - GYPBOARD CEILING
NTS
DOWNLIGHT MOUNTING - LAY-IN CEILING
NTS
EXIT SIGN MOUNTING - LAY-IN CEILING
NTS
FIXTURE WHIP FROM JUNCTION
BOX (1829mm (6') LONG MAX)
CEILING MAIN BEAM
RECESSED CAN
LUMINAIRE
REFER TO
SCHEDULE.
CEILING CROSS
BEAM
WIRE TIE OR SCREW BAR
HANGER TO CROSS BEAM
TYP.
CEILING HANGER WIRE,
TYP.
LUMINAIRE SUSPENSION WIRES
REFER TO SPECIFICATION SECTION 26 51 00
LUMINAIRE
BAR HANGERS
GYPSUM BOARD
(TYP)
RECESSED CAN
LUMINAIRE
CEILING BEAM
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING
THE RECOMMENDED MOUNTING HARDWARE.
LOCKING SQUARE WASHER
& LOCKNUT
INTEGRAL
GALVANIZED
LIPPED STEEL
MOUNTING
CHANNEL
WASHER &
LOCKNUT
REFER TO PLANS FOR
QUANTITY & SIZE OF
CONDUITS
CONDUIT CLAMP. SIZE AS
REQUIRED
GENERAL NOTES:
2. FASTEN THREADED ROD TO STRUCTURE BY APPROVED METHOD PER
SPECIFICATION 26 05 33, RACEWAY AND BOXES FOR ELECTRICAL
SYSTEMS. FIELD VERIFY EXACT CONDITIONS.
3. FOR TRAPEZE INSTALLATIONS IN SEISMIC AREAS REFER TO SPECIFICATION
SECTION 13 05 41, SEISMIC RESTRAINT REQUIREMENTS FOR
NON-STRUCTURAL COMPONENTS.
FIRESTOP SEALANT
PER SECTION 07 84 00,
FIRESTOPPING
CONDUIT, TYP
FLOOR SLAB,
TYP.
INTEGRAL GALVANIZED LIPPED
STEEL MOUNTING CHANNEL,
TYP.
MINERAL WOOL
(FIRMLY PACKED)
STEEL EXPANSION ANCHOR,
TYP
9.52mm
SPRING
NUT, TYP
CONDUIT FITTINGJUNCTION BOX
(SIZE AS REQUIRED)
CEILING HANGER WIRE,
TYP.
LUMINAIRE SUSPENSION WIRE
REFER TO SPECIFICATION SECTION 26 51
00.
WIRE TIE OR SCREW BAR
HANGER TO
ARCHITECTURAL CEILING
GRID TYP.
ARCHITECTURAL CEILING
GRID
RECESSED CAN
LUMINAIRE
ACOUSTICAL CEILING
TILE (TYP)
LUMINAIRE
BAR HANGERS
RECESSED CAN
LUMINAIRE
ARCHITECUTRAL
CEILING GRID
FIXTURE WHIP FROM JUNCTION
BOX (1829mm (6') LONG MAX)
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND
USING RECOMMENDED MOUNTING HARDWARE
WATER CUT-OFF MASTIC
COMPATIBLE WITH ROOF
MEMBRANE
INTEGRAL GALVANIZED
LIPPED STEEL MOUNTING
CHANNEL
ROOF
ROOF MEMBRANE
STAINLESS CLAMP, TYP.
SEAL-OFF
FITTING, TYP.
CONDUIT, TYP. BATT INSULATION
STEEL
EXPANSION
ANCHOR
9.52mm (3/8")
MIN GALVANIZED
THREADED ROD,
TYP.
LOCKING SQUARE
WASHER &
LOCKNUT
CONDUIT CLAMP.
SIZE AS REQUIREDGENERAL NOTES:
1. MAINTAIN A MINIMUM CLEARANCE OF 305mm (12") ON ALL SIDES OF ROOF PENETRATION FROM
WALLS, CURBS, AND OTHER PROJECTIONS TO FACILITATE PROPER FLASHING.
2. FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT OR OVERLAPPED.
3. VERIFY ROOF & STRUCTURAL SYSTEM WITH ARCHITECT.
4. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR TO ENSURE PROPER METHODS
& MATERIALS ARE USED TO MAINTAIN ROOF WARRANTY.
EXPANSION FITTING WITH
BONDING JUMPER
SEISMIC OR EXPANSION
JOINT. FIELD VERIFY ACTUAL
CONDITIONS & LOCATIONS.
FLOOR OR ROOF STRUCTURE. FIELD
VERIFY ACTUAL CONDITIONS, TYP.
STRUCTURAL MEMBER (BEAM,
JOIST, ETC.), TYP.
STEEL EXPANSION
ANCHOR
INSULATING
BUSHING
CONDUIT, TYP.
HEAD
CONDUIT TRAPEZE
PER SD260533-03,
TYP.
914mm
SPRING NUT
BEAM CLAMP,
TYP.
JUNCTION BOX, TYP
(SIZE AS REQUIRED)
INTEGRAL GALVANIZED
LIPPED STEEL MOUNTING
CHANNEL
JUNCTION BOX (SIZE AS
REQUIRED)
CONDUIT FITTING
PROVIDE EXTRA CABLE TO MAKE
COMPLETE LOOP AROUND BOX
PERIMETER
GENERAL NOTES:
1. INSTALLATION IS ACCEPTABLE ALTERNATE TO DETAIL SD260533-01.
2. INSTALLATION IS REQUIRED FOR CONDUIT 76mm (3") AND LARGER.
(3'-0") MAX
(3/8") MAX
PROVIDE 127mm (5") OF SLACK AT MIDPOINT
BETWEEN TWO END OF FLEXIBLE GALVANIZED
STEEL CONDUIT. PROVIDE GREEN INSULATED
COPPER EQUIPMENT GROUNDING CONDUCTOR
WITH FLEXIBLE CONDUIT.
FLOOR OR ROOF STRUCTURE. FIELD
VERIFY ACTUAL CONDITIONS, TYP.
SEISMIC OR EXPANSION
JOINT. FIELD VERIFY ACTUAL
CONDITIONS & LOCATIONS.
STRUCTURAL MEMBER (BEAM,
JOIST, ETC.), TYP.
STEEL EXPANSION
ANCHOR
CONDUIT, TYP.
CONDUIT TRAPEZE
PER SD260533-03,
TYP.
914mm
(3'-0") MAX
BEAM CLAMP,
TYP.
JUNCTION BOX, TYP
(SIZE AS REQUIRED)
INTEGRAL GALVANIZED
LIPPED STEEL MOUNTING
CHANNEL
JUNCTION BOX (SIZE AS
REQUIRED)
CONDUIT FITTING
SPRING NUT
PROVIDE EXTRA CABLE TO MAKE
COMPLETE LOOP AROUND BOX
PERIMETER
GENERAL NOTE:
1. DETAIL IS APPLICABLE ONLY FOR CONDUIT SMALLER THAN 76mm (3").
LUMINAIRE MANUFACTURER'S MOUNTING
HARDWARE
REFER TO SPECIFICATION SECTION 26 51 00
FIXTURE WHIP FROM
JUNCTION BOX
(1829mm (6') LONG
MAX.)
LUMINAIRE.
REFER TO
SCHEDULE
LUMINAIRE SUSPENSION
WIRES REFER TO
SPECIFICATION SECTION
26 51 00
3 TWIST MINIMUM
(TYP)
ARCHITECTURAL CEILING
GRID
LUMINAIRE.
REFER TO
SCHEDULE
ACOUSTICAL CEILING TILE
(TYP)
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND
USING THE RECOMMENDED MOUNTING HARDWARE.
LUMINAIRE.
REFER TO
SCHEDULE
DRYWALL BORDER
LUMINAIRE MANUFACTURER'S MOUNTING
HARDWARE
REFER TO SPECIFICATION SECTION 26 51 00
FIXTURE WHIP FROM
JUNCTION BOX
(1829mm (6') LONG
MAX.)
LUMINAIRE.
REFER TO
SCHEDULE
LUMINAIRE SUSPENSION
WIRES REFER TO
SPECIFICATION SECTION
26 51 00
3 TWIST MINIMUM
(TYP)
GYPSUM BOARD (TYP)
CEILING CROSS BEAM
CEILING MAIN BEAM
CEILING CROSS BEAM
GYPSUM BOARD
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS
AND USING THE RECOMMENDED MOUNTING HARDWARE.
FIXTURE WHIP FROM JUNCTION BOX
(1829mm (6') LONG MAX)
HANGER WIRE AND MOUNTING CHANNEL
ATTACHED TO STRUCTURE
REFER TO SPECIFICATION SECTION
26 51 00
INTEGRAL GALVANIZED LIPPED STEEL
MOUNTING CHANNEL
WIRE TIE THROUGH
MOUNTING CHANNEL &
CROSS BEAM, TYP.
ARCHITECTURAL
CEILING GRID
ACOUSTICAL
CEILING TILE
(TYP)
ARCHITECTURAL
CEILING GRID
6.35mm (1/4") SCREW
JUNCTION BOX
LOCKING SQUARE
WASHER & NUT
ARCHITECTURAL
CEILING GRID
CEILING HANGER WIRE
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING
THE RECOMMENDED MOUNTING HARDWARE.
PREFABRICATED FORMED 1.52mm
(0.06") THICK ALUMINUM FLASHING
ROUND COLLAR WITH MIN. 76mm
(3") WIDE FLANGE. ATTACH TO
ROOF PER MANUFACTURER'S
MULTIPLE MEMBRANE STRIPPING
PLIES FEATHERED AT FIELD OF
ROOF BY ROOFING CONTRACTOR.
PRIME FLANGE BEFORE STRIPPING.
INSTRUCTIONS
PREFABRICATED RUBBER
BOOT CAP WITH GRADUATED
STEPS & WEATHER-PROOF
PRESSURE SEAL TO COLLAR
SEALANT AT PENETRATION
TO MEMBRANE JUNCTURE
BY ROOFING CONTRACTOR
CONDUIT CLAMP.
SIZE AS REQUIRED
INTEGRAL
GALVANIZED
LIPPED STEEL
MOUNTING
CHANNEL
1. INTEGRAL GALVANIZED LIPPED STEEL MOUNTING
CHANNEL LONGER THAN 915mm (36") SHALL BE INSTALLED
WITH A CENTER SUPPORT ROD.
9.52mm (3/8") MIN
GALVANIZED
THREADED ROD,
TYP.
FLUSH AGAINST CEILING
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHILLICOTHE VA MEDICAL CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
© Copyright 2017
2690 W. Dublin-Granville Road, Columbus, OH 43214
p. 614.267.6603 www.DesignLeveLarchitecture.com
DesignLeveL planning interior design architecture
C :\U se rs
\th am
\D oc um en ts \1
0- B
-E le c-
C en tr al
_t ha m .r vt
BID DOCUMENTS
E001
CCTS
ELECTRICAL DETAILS
5/22/2017
538-115CORRECT PRIVACY/
SAFETY/ENVIRONMENTAL
ISSUES IN BUILDING 26
855 Grandview Avenue, 3rd Floor Columbus, OH 43215
Phone: (614) 443-1178 Fax: (614) 443-1594
Email: dynamix@dynamix-ltd.com
Facility Engineering Consultants
Engineering Ltd.
DEL # 140120
GI
R
S
S
R P
F E
O
E E
T
L
I G
S
NA
O N
R E
E
D
I
R
S
E N
E
HT
A
T
S
E OF
MACE E-50556
O
OI
MONTGOMERY E-66852
GRIFFIN E-57049
AS-BUILT
UPUP
ATS
J
EBS
BS
KP
BN EBN
MEP
EDP2
EDP1
26-ATS
26-MDPE
E
E
E
E
FACP
F/A NAC
E E
E
EXISTING BUILDING 26 TRANSFORMER
Storage
Stair
S2-0
Linen
Linen Storage
7 EMS Supervisor
MER
CIO
P1 Equipment
Equipment
9A
Elec Closet
4D
Toilet
4A
HAC
Recreation
2A
EMS Storage
EMS Storage
Recreation Clinic
Storage
4C
Craft
4B
Stair
S1-0
Men's Toilet
Women's Toilet
HAC
Tele
27A
Social Work Service
EMS Office
EMR
Stair
S5-0
Cooridor
Chapel
Canteen Storage
Storage
25A Toilet
23A
MER
Stair
S3-0
Employee Health Rest Area
18A
Storage
18B
Occupational Safety &
Health Manager 18C
Employee Health Exam
18D
Employee Health Phy
Extender 18E
Employee's Health
Program Support Clerk 18F
Industrial Hygenist
18G
GEMS Coordinator
18H
Safety Program Support
Specialist 18I
Employee Health
MER
Canteen Storage
Supply Room
EMS Storage
24A
Stair
S4-0
(26-C1)E
26-DP1
E
E
E
E
E
6 6 7
8 8
26-P2
26-P1
(26-ACRC1)E
PLAN NOTES
1.- EXISTING SIMPLEX 4100ES FIRE ALARM CONTROL PANEL.
2.- LOCATION OF EXISTING SCHNEIDER ELECTRIC GENERATOR NETWORK PANEL.
REFER TO TECHNOLOGY PLANS FOR WORK ASSOCIATED WITH MAINTAINING
SERVICE. NEW ATS SHALL BE TIED BACK INTO THE EXISTING SYSTEM. ALL
REQUIRED PROGRAMMING SHALL BE PROVIDED TO UPDATE SYSTEM.
3.- DISCONNECT AND REMOVE EXISTING 208V, 400A AUTOMATIC TRANSFER
SWITCH. ALL CONDUIT AND CABLE TO BE RECONFIGURED FOR INSTALLATION OF
NEW TRANSFER SWITCH IN SAME LOCATION. NEW TRANSFER SWITCH IS TO BE
INTEGRATED INTO THE EXISTING SCHNEIDER ELECTRIC GENERATOR NETWORK
SYSTEM. PROVIDE ALL REQUIRED SCHNEIDER ELECTRIC SYSTEM PROGRAMMING
TO INCORPORATE NEW OWNER PROVIDED ATS INTO SYSTEM.
4.- LOCATION OF EXISTING GENERATOR THAT IS FEEDING BUILDING 26 AND
NEIGHBORING BUILDING 27.
5.- LOCATION OF EXISTING PRIMARY DISTRIBUTION TRANSFORMER FEEDING
BUILDING 26.
6.- DISCONNECT AND REMOVE EXISTING RECEPTACLE. DEMO CIRCUITRY BACK TO
JUNCTION BOX TO BE RELOCATED.
7.- CAREFULLY REMOVE EXISTING JUNCTION BOX. JUNCTION BOX TO BE
RELOCATED TO ACCOMMODATE THE CONSTRUCTION OF THE NEW WALLS.
RECONFIGURE EXISTING CIRCUITRY AND CONDUIT ENTERING JUNCTION BOX AS
REQUIRED. REFER TO NEW WORK PLANS.
8.- DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. DEMO ASSOCIATED
CIRCUITRY BACK TO LIGHT FIXTURES REMAINING. RECONFIGURE CIRCUITRY AS
REQUIRED AS EXISTING LIGHT FIXTURES ARE SWITCHED WITHIN THEIR
RESPECTIVE ROOM. NEW LIGHT FIXTURES ARE TO BE INSTALLED WITHIN
CORRIDOR AND CIRCUITED SEPARATELY. REFER TO NEW WORK PLAN.
9.- EXISTING LIGHT FIXTURES ARE TO REMAIN. RECONFIGURE EXISTING
CIRCUITRY SO LIGHT FIXTURES ARE SWITCHED SEPARATELY. REFER TO NEW
WORK PLAN.
10.- DISCONNECT AND REMOVE EXISTING LIGHT SWITCH. DEMO CIRCUITRY BACK
TO NEXT LIVE DEVICE. CIRCUITRY AND SWITCHING OF LIGHT FIXTURES TO BE
RECONFIGURED FOR NEW ROOM LAYOUT. REFER TO NEW WORK PLAN.
11.- DISCONNECT EXISTING PUMP AND REMOVE EXISTING COMBINATION
MOTOR STARTER/DISCONNECT SWITCH FEEDING PUMP. DEMO CIRCUITRY AND
EXPOSED CONDUIT BACK TO SOURCE. COORDINATE DISCONNECTION WITH
DIVISION 23.
12.- EXISTING SCHNEIDER ELECTRIC GENERATOR NETWORK PANEL. SYSTEM IS TO
BE REPROGRAMMED AS REQUIRED TO INCORPORATE REPLACED ATS INTO
SYSTEM.
13.- NOTE NOT USED.
14.- NOTE NOT USED.
15.- EXISTING CONDENSATE PUMP TO REMAIN.
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHILLICOTHE VA MEDICAL CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
© Copyright 2017
2690 W. Dublin-Granville Road, Columbus, OH 43214
p. 614.267.6603 www.DesignLeveLarchitecture.com
DesignLeveL planning interior design architecture
C :\U se rs
\th am
\D oc um en ts \1
0- B
-E le c-
C en tr al
_t ha m .r vt
BID DOCUMENTS
ED100
CCTS
BASEMENT ELEC DEMO
PLAN
5/22/2017
538-115CORRECT PRIVACY/
SAFETY/ENVIRONMENTAL
ISSUES IN BUILDING 26
855 Grandview Avenue, 3rd Floor Columbus, OH 43215
Phone: (614) 443-1178 Fax: (614) 443-1594
Email: dynamix@dynamix-ltd.com
Facility Engineering Consultants
Engineering Ltd.
DEL # 140120
SCALE: 1/8" = 1'-0"
BASEMENT ELEC DEMO PLAN
GI
R
S
S
R P
F E
O
E E
T
L
I G
S
NA
O N
R E
E
D
I
R
S
E N
E
HT
A
T
S
E OF
MACE E-50556
O
OI
MONTGOMERY E-66852
DN
UP
UP
UP
UP
UP
UP UP
DN
JJ
J
J
J
J
J
J
J
J
J
J
J
JJ
J J J J
J
J
J J
J
J
J
J J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
L
L
E1S
1S 1N E1N
3 3 3
3 3
E
E E E E
E E
E
8 8 8 8
8 8
8 8
8 8 8 8
8 8
8 8
2 Bed Room
Storage
2 Bed Room
Storage
119 Storage
Toilet/Shower
118A
Toilet/Shower
122A
2 Bed Room
1 Bed Room
Cooridor
100F
Tub/Laundry Room
Toilet
117A Nurse Station
Storage
116A
Toilet/Shower
115A
1 Bed Room
Closet
107A
Elec Closet
HAC
Stair
S2-1
1 Bed Room
1 Bed Room
1 Bed Room
HAC Storage
Toilet/Shower
110A
Staff Locker Room
Staff Toilet
111A
Cooridor
100G
Cooridor
100H
Stair
S1-1
Physician
Break Room
Social Worker
Toilet/Shower
104A
Linen Chute
Toilet
126A
1 Bed Room
Visitor's Room
Cooridor
100D
Toilet
128A
Staff Toilet
Nurse Manager
Exam & Interview
Med Carts
Med Prep
101A
Nurse Station
Cooridor
100C
SPD Storage
Signal Closet
130 Cooridor
100A
Cooridor
100B
Clean Linen
Signal Closet
Telephone Closet
Patient Toilet
Stair
S5-1
Patient Dining Room
Kitchenette
Vestibule
Patient Lounge
Patient Telephones
2 Bed Room
1 Bed Room
Toilet/Shower
162A
Toilet/Shower
137A
2 Bed Room
2 Bed Room
Cooridor
100E
Stair
S3-1
Elec Closet
HAC
1 Bed Room
2 Bed Room
Toilet/Shower
139A Storage
Storage
2 Bed Room
Storage
Toilet/Shower
143A
2 Bed Room
Cooridor
100I
Ante Room
1 Bed Room
1 Bed Room
Ante Room
Toilet/Shower
147AStorage
148A
Soiled Utility
PA Office
Treatment Team Room
Cooridor
100J
Treatment Team Room
Social Worker
Psychiatrist
Social Worker
Social Worker
Psychiatrist
Storage
Stair
S4-1
E
E
E
E
E
6 6
E
E
E
E
E
6 6
E
E E E E
DEDUCT ALTERNATE 3
DEDUCT ALTERNATE 1
DEDUCT ALTERNATE 4
PLAN NOTES
1.- DISCONNECT AND REMOVE EXISTING PANELBOARD. DEMO CIRCUITRY AND
CONDUIT BACK TO SOURCE. REFER TO SINGLE LINE DIAGRAM FOR FURTHER
INFORMATION.
2.- EXISTING CONDUIT FEEDING THROUGH CLOSET UP TO PANELBOARD ON
FLOOR ABOVE FROM BASEMENT. CONDUIT AND CIRCUITRY TO BE REMOVED AND
DEMOED BACK TO SOURCE. PANELS ON FLOOR ABOVE ARE TO BE RE-FED.
3.- DISCONNECT AND REMOVE ALL INTERIOR ELECTRICAL DEVICES (RECEPTACLES,
LIGHT FIXTURES AND ASSOCIATED SWITCHES, FIRE ALARM DEVICES, SURFACE
RACEWAY AND BOXES, PANELS, ETC.) IN THIS AREA UNLESS NOTED OTHERWISE.
REMOVE ALL CONDUIT AND WIRE BACK TO SOURCE. REFER TO NEW WORK PLAN
FOR INSTALLATION OF NEW DEVICES.
4.- EXISTING LOCATION OF LIGHTNING PROTECTION SYSTEM DOWNRUNNER AND
GROUNDING ROD. DEMO EXISTING DOWNRUNNER AND GROUND ROD.
LIGHTNING PROTECTION SYSTEM IS TO REMAIN AND TO BE EXTENDED TO NEW
ADDITION. REFER TO NEW WORK PLANS.
5.- DISCONNECT EXISTING FLUSH MOUNTED LIGHT FIXTURE. REMOVE LIGHT
FIXTURE, CIRCUITRY, AND CONDUIT BACK TO SOURCE.
6.- EXISTING STAIRWELL LIGHT FIXTURE TO REMAIN. DEMO EXISTING CIRCUITRY
FROM EXISTING PANELBOARD. EXISTING CIRCUITRY TO BE EXTENDED TO NEW
PANELBOARD CIRCUIT AS SHOWN ON NEW WORK PLANS.
7.- DISCONNECT AND REMOVE EXISTING WATER CLOSET SENSOR IN CHASE.
DEMO CIRCUITING AND CONDUIT BACK TO SOURCE.
8.- DISCONNECT EXISTING FAN COIL UNIT. DEMO CIRCUITING AND CONDUIT
BACK TO SOURCE.
9.- DISCONNECT EXISTING CIRCUIT FEEDING THE WALL MOUNTED EXTERIOR
LIGHT FIXTURES. FIXTURES AND CONCEALED CIRCUITRY TO REMAIN. CIRCUIT IS
TO BE RE-FED FROM NEW PANELBOARD. REFER TO NEW WORK PLANS.
10.- DISCONNECT EXISTING CIRCUIT FEEDING LIGHTING IN ELEVATOR SHAFT.
CIRCUIT IS TO BE EXTENDED TO NEW PANELBOARD LOCATION. REFER TO NEW
WORK PLANS.
11.- DISCONNECT EXISTING TUB. DEMO CIRCUITRY AND CONDUIT BACK TO
SOURCE. DEMO ALL ASSOCIATED DISCONNECT SWITCHES.
12.- DISCONNECT AND REMOVE EXISTING EXIT SIGN. DEMO CIRCUITRY BACK TO
SOURCE. BACKBOX AND CONCEALED CONDUIT WITHIN EXISTING WALL TO ABOVE
ACCESSIBLE CEILING TO REMAIN FOR INSTALLATION OF NEW EXIT SIGN IN SAME
LOCATION.
13.- DEDUCT ALTERNATE 3: IF ALTERNATE 3 IS ACCEPTED, THIS SPACE IS TO
REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING
THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW
PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD
LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.
14.- DEDUCT ALTERNATE 1: IF ALTERNATE 1 IS ACCEPTED, THIS SPACE IS TO
REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING
THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW
PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD
LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.
15.- DEDUCT ALTERNATE 4: IF ALTERNATE 4 IS ACCEPTED, THIS SPACE IS TO
REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING
THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW
PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD
LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHILLICOTHE VA MEDICAL CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
© Copyright 2017
2690 W. Dublin-Granville Road, Columbus, OH 43214
p. 614.267.6603 www.DesignLeveLarchitecture.com
DesignLeveL planning interior design architecture
C :\U se rs
\th am
\D oc um en ts \1
0- B
-E le c-
C en tr al
_t ha m .r vt
BID DOCUMENTS
ED101
CCTS
FIRST FLOOR ELEC DEMO
PLAN
5/22/2017
538-115CORRECT PRIVACY/
SAFETY/ENVIRONMENTAL
ISSUES IN BUILDING 26
855 Grandview Avenue, 3rd Floor Columbus, OH 43215
Phone: (614) 443-1178 Fax: (614) 443-1594
Email: dynamix@dynamix-ltd.com
Facility Engineering Consultants
Engineering Ltd.
DEL # 140120
SCALE: 1/8" = 1'-0"
FIRST FLOOR ELEC DEMO PLAN
GI
R
S
S
R P
F E
O
E E
T
L
I G
S
NA
O N
R E
E
D
I
R
S
E N
E
HT
A
T
S
E OF
MACE E-50556
O
OI
MONTGOMERY E-66852
GRIFFIN E-57049
AS-BUILT
rviviano Rectangle
DN
UP
DN
DN
2S
E2S
E E
E2N
2N
Bed Room
Bed Room
Bed Room
Bed Room
Toilet
217A
Storage
Storage
Toilet
220A
Corridor
200F
Congregate Bath
Congregate Shower
216A
Soiled Utility
Congregate Toilet
Stair
S2-2
Elec Closet
HVAC
Storage
Toilet
205A
Toilet
209AToilet
210A
Bed Room
Bed Room
Bed Room
Bed Room
Toilet
211A
Linen Storage
Stair
S1-2
Corridor
200K
Bed Room
Corridor
200D
Toilet
225A
Quiet Room
Linen Chute
MIT
Exam Room
Toilet
227A
Female Toilet
Sterile Supplies
Nourishment Kitchen
Med Prep
201A
Nurse Station
Physician
Corridor
200C
Elec Closet
Corridor
200B
EMS Storage
Telephone Closet
Telephone Closet
Break Room
Corridor
200A
Stair
S5-2
Toilet
256A
Staff Toilet
Toilet
231A
Day Room
Break Room
Bed Room
Bed Room
Toilet
255A
Storage
Corridor
200E
Bed Room
Nurse Manager
Bed Room
Toilet
253A Storage
HAC
Elec Closet
Stair
S3-2
Female Shower
Corridor
200I
Bed Room
Bed Room
Bed Room
Toilet
238A
Toilet
239A
Storage
Conference Room
Congregate Bath
Congregate Shower
242A
Soiled Utility
Congregate Toilet
Bed Room
Toilet
249A Toilet
248A
Bed Room
Bed Room
Bed Room
Toilet
245A
Linen Room
Corridor
200J Stair
S4-2
12.0
11.0
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
B.0
E.1
3.2
2.4
1.6
L.0 J.0
C.5
C.0 D.0C.1 C.9
F.0 G.0 G.5E.5 F.3F.4 G.3 G.8
H.9 L.1G.4 H.0 M.0
7.2
A.0 E.0
U.0
S.5
T.0S.0 S.9S.1
Q.0P.0N.0 Q.5P.2N.3M.5 N.2 V.0R.0
Q.2P.1N.5M.1
J.5H.7G.9G.2G.1E.7
13.0
10.1
9.1
8.8
7.6
7.5
L.3
E.7
E.7
G.1
G.1
G.2
G.2
G.9
G.9
H.7
H.7
J.5
J.5
L.3
L.3
M.1
M.1
N.5
N.5
P.1
P.1
Q.2
Q.2
13.0 13.0
10.1 10.1
9.1 9.1
8.8 8.8
7.6 7.6
7.5 7.5
14.0 14.0
PLAN NOTES
1.- DISCONNECT EXISTING PANELBOARD AND DEMO CIRCUITRY AND CONDUIT
BACK TO SOURCE. PANELBOARD IS TO REMAIN AND TO BE RE-FED. REFER TO
NEW WORK PLANS AND SINGLE LINE DIAGRAM FOR FURTHER INFORMATION.
2.- CAREFULLY DISCONNECT AND REMOVE EXISTING 208V, 60A, 3-POLE
DISCONNECT SWITCH FOR DRYER. EXISTING SWITCH IS TO BE RELOCATED TO
NEW WALL BEING INSTALLED AROUND DUCTWORK PASSING THROUGH.
RECONFIGURE EXISTING CIRCUITRY AS REQUIRED.
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHILLICOTHE VA MEDICAL CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
© Copyright 2017
2690 W. Dublin-Granville Road, Columbus, OH 43214
p. 614.267.6603 www.DesignLeveLarchitecture.com
DesignLeveL planning interior design architecture
C :\U se rs
\th am
\D oc um en ts \1
0- B
-E le c-
C en tr al
_t ha m .r vt
BID DOCUMENTS
ED102
CCTS
SECOND FLOOR ELEC
DEMO PLAN
5/22/2017
538-115CORRECT PRIVACY/
SAFETY/ENVIRONMENTAL
ISSUES IN BUILDING 26
855 Grandview Avenue, 3rd Floor Columbus, OH 43215
Phone: (614) 443-1178 Fax: (614) 443-1594
Email: dynamix@dynamix-ltd.com
Facility Engineering Consultants
Engineering Ltd.
DEL # 140120
SCALE: 1/8" = 1'-0"
SECOND FLOOR ELEC EXISTING PLAN
GI
R
S
S
R P
F E
O
E E
T
L
I G
S
NA
O N
R E
E
D
I
R
S
E N
E
HT
A
T
S
E OF
MACE E-50556
O
OI
MONTGOMERY E-66852
PLAN NOTES
1.- EXISTING AIR HANDLING UNIT TO REMAIN.
26-DP1A
E
(26-AHU3)E
(26-CEF2)E
(26-AHU4)E
AP
E
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHILLICOTHE VA MEDICAL CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
© Copyright 2017
2690 W. Dublin-Granville Road, Columbus, OH 43214
p. 614.267.6603 www.DesignLeveLarchitecture.com
DesignLeveL planning interior design architecture
C :\U se rs
\th am
\D oc um en ts \1
0- B
-E le c-
C en tr al
_t ha m .r vt
BID DOCUMENTS
ED103
CCTS
ATTIC ELEC DEMO PLAN
5/22/2017
538-115CORRECT PRIVACY/
SAFETY/ENVIRONMENTAL
ISSUES IN BUILDING 26
855 Grandview Avenue, 3rd Floor Columbus, OH 43215
Phone: (614) 443-1178 Fax: (614) 443-1594
Email: dynamix@dynamix-ltd.com
Facility Engineering Consultants
Engineering Ltd.
DEL # 140120
SCALE: 1/8" = 1'-0"
ATTIC ELEC EXISTING PLAN
GI
R
S
S
R P
F E
O
E E
T
L
I G
S
NA
O N
R E
E
D
I
R
S
E N
E
HT
A
T
S
E OF
MACE E-50556
O
OI
MONTGOMERY E-66852
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1 C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1 C1
C1 C1
C1 C1
C1
C1 C1
C1
C1 C1
C1
C1 C1
C1
C1 C1
C1
C1
C1 C1 C1 C1 C1 C1
C1 C1 C1 C1 C1 C1 C1 C1
C1
C1C1
GTD
GTD GTD
GTD
GTD
GTD GTD
GTD
C1 C1 C1
R3
E
E
E
E
OS
X1
X1
OS
C1 C1 C1 C1 C1C1
C1
GTD
1S2-15
1S2-17
1N2-20
1N2-22
EL1-25
EL1-25
EL1-25
EL1-25
EL1-25
EL1-25
EL1-25 EL1-25 EL1-25
EL1-25 EL1-25
Storage
Stair
S2-0
Linen
Linen Storage
7 EMS Supervisor
MER
CIO
P1 Equipment
Equipment
9A
Elec Closet
4D
Toilet
4A
HAC
Recreation
2A
EMS Storage
EMS Storage
Recreation Clinic
Storage
4C
Craft
4B
Stair
S1-0
Men's Toilet
Women's Toilet
HAC
Tele
27A
Social Work Service
EMS Office
EMR
Stair
S5-0
Cooridor
Chapel
Canteen Storage
Storage
25A Toilet
23A
MER
Stair
S3-0
Employee Health Rest Area
18A
Storage
18B
Occupational Safety &
Health Manager 18C
Employee Health Exam
18D
Employee Health Phy
Extender 18E
Employee's Health
Program Support Clerk 18F
Industrial Hygenist
18G
GEMS Coordinator
18H
Safety Program Support
Specialist 18I
Employee Health
MER
Canteen Storage
Supply Room
EMS Storage
24A
Stair
S4-0
PIPE BASEMENT
CORRIDOR
(BASEMENT)
C32A
PLAN NOTES
1.- RECIRCUIT EXISTING LIGHT FIXTURES TO EXISTING CIRCUIT. RECONFIGURE
CIRCUITRY SO LIGHT FIXTURES ARE CONTROLLED BY NEW OCCUPANCY SENSOR.
2.- LIGHT FIXTURES SHALL BE HUNG AT 9'-0" AFF. ALL FIXTURES SHALL BE CLOSELY
COORDINATED WITH ALL DUCTWORK TO EITHER BE MOUNTED SLIGHTLY BELOW
DUCTWORK OR TO BE SHIFTED CLEAR OF DUCTWORK. NO FIXTURES SHALL BE
MOUNTED ABOVE DUCTWORK.
Drawing Title
Approved:
Project Title
Date
Location
Checked By:
Building Number
Project Number
Drawing Number
Drawn By:
Revisions: Date
ARCHITECT/ENGINEERS:
CHILLICOTHE VA MEDICAL CENTER
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
© Copyright 2017
2690 W. Dublin-Granville Road, Columbus, OH 43214
p. 614.267.6603 www.DesignLeveLarchitecture.com
DesignLeveL planning interior design architecture
C :\U se rs
\th am
\D oc um en ts \1
0- B
-E le c-
C en tr al
_t ha m .r vt
BID DOCUMENTS
EL100
CCTS
BASEMENT LIGHTING PLAN
5/22/2017
538-115CORRECT PRIVACY/
SAFETY/ENVIRONMENTAL
ISSUES IN BUILDING 26
855 Grandview Avenue, 3rd Floor Columbus, OH 43215
Phone: (614) 443-1178 Fax: (614) 443-1594
Email: dynamix@dynamix-ltd.com
Facility Engineering Consultants
Engineering Ltd.
DEL # 140120
SCALE: 1/8" = 1'-0"
BASEMENT LIGHTING PLAN
GI
R
S
S
R P
F E
O
E E
T
L
I G
S
NA
O N
R E
E
D
I
R
S
E N
E
HT
A
T
S
E OF
MACE E-50556
O
OI
MONTGOMERY E-66852
DNDN
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
PLAN NOTES
1.- EXTEND EXISTING STAIRWELL LIGHTING CIRCUIT TO NEW PANELBOARD
SHOWN. RECONFIGURE EXISTING CIRCUITRY AS REQUIRED.
2.- EXTEND EXISTING EXTERIOR WALL MOUNTED FIXTURE LIGHTING CIRCUIT TO
NEW PANELBOARD SHOWN. RECONFIGURE EXISTING CIRCUITRY AS REQUIRED.
3.- EXTEND EXISTING ELEVATOR LIGHTING CIRCUIT TO NEW PANELBOARD
LOCATION. RECONFIGURE ALL EXISTING CIRCUITRY AS REQUIRED.
4.- ROUTE LIGHTING CIRCUIT THROUGH LIGHTING RELAY PANEL ZONE
INDICATED.
5.- PROVIDE LOW-VOLTAGE RELAY OVERRIDE SWITCH CONTROLLING ZONES
SPECIFIED. PROVIDE ONE BUTTON PER ZONE. CLEARLY LABEL ALL BUTTONS WITH
WHAT LOAD THEY ARE CONTROLLING.
6.- PROVIDE DEVICE IN EXISTING STUD WALL. EXISTING WALL SHALL BE PATCHED
AND REPAIRED TO EXISTING CONDITION UPON INSTALLATION OF DEVICES.
7.- INSTALL NEW EXIT SIGN IN EXISTING WALL. UTILIZE EXISTING BACKBOX AND
CONCEALED CONDUIT WITHIN EXISTING WALL TO ABOVE ACCESSIBLE CEILING
FOR MOUNTING AND ROUTING CIRCUITRY.
8.- CEILING MOUNT EXIT SIGN AS CLOSE TO WALL AS POSSIBLE.
9.- DEDUCT ALTERNATE 3: IF ALTERNATE 3 IS ACCEPTED, THIS SPACE IS TO
REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING
THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW
PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD
LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.
10.- DEDUCT ALTERNATE 1: IF ALTERNATE 1 IS ACCEPTED, THIS SPACE IS TO
REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING
THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW
PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD
LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.
11.- DEDUCT ALTERNATE 4: IF ALTERNATE 4 IS ACCEPTED, THIS SPACE IS TO
REMAIN AS IS AND IS NOT TO BE RENOVATED. ALL EXISTING CIRCUITRY FEEDING
THE EXISTING LIGHTING, DEVICES, AND EQUIPMENT IS TO BE EXTENDED TO NEW
PANELBOARD LOCATIONS. REFER TO NEW WORK PLAN FOR PANELBOARD
LOCATIONS. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.
12.- DEDUCT ALTERNATE 2: IF ALTERNATE 2 IS ACCEPTED, THIS SPACE IS TO BE
SHELL SPACE ONLY. NO LIGHTING OR DEVICES ARE TO BE INSTALLED WITHIN
SPACE. REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.
13.- NOTE NOT IN USE.
14.- DEDUCT ALTERNATE 2: IF ALTERNATE 2 IS ACCEPTED, THIS SPACE IS TO BE
UTILIZED AS A DUAL OCCUPANCY ROOM. REARRANGE QUIET ROOM LIGHTING
TO ACCOMODATE ADDITIONAL BED. PROVIDE ONE ADDITIONAL D1 FIXTURE AND
WALL MOUNT LIGHT SWITCH FOR MOUNTING AT HEAD OF ADDITIONAL BED.
REFER TO SPECIFICATION 01 00 00 FOR ALTERNATE INFORMATION.
STAFF LOUNGE /
LOCKERS
CONFERENCE
ROOM
EQUIPMENT
STORAGE
TOILET
ELEC.
INTAKE ROOM
VESTIBULE
VISITOR ROOM
SHARED
WORKROOM
EXAM ROOM
PATIENT ROOM
TYPE B
PATIENT
BATHROOM TYPE
1D
128A
PATIENT ROOM
TYPE B
WAITING
HAC
LINEN VESTIBULE
LINEN CHUTE
130A
STORAGE
133A
PATIENT ROOM
TYPE B
PATIENT
BATHROOM TYPE
1B
125A
PATIENT ROOM
TYPE B
PATIENT ROOM
TYPE A
PATIENT
BATHROOM TYPE
1B
127A
PATIENT
BATHROOM TYPE
1B
124A
PATIENT
BATHROOM TYPE
1A
122A
PATIENT ROOM
TYPE A
PATIENT
BATHROOM TYPE
1B
121A
STORAGE
120A
MED ROOM
TREATMENT TEAM
ROOM
TUB ROOM
ELEC.
TOILET
CONSULT ROOM
CONSULT ROOM
NURSE STATION
ISOLATION ROOM
110A
PATIENT
BATHROOM TYPE
1D
114A
PATIENT ROOM -
TYPE B
ISOLATION ANTE
ROOM
PATIENT ROOM
TYPE A
111 PATIENT
BATHROOM
TYPE1A
109A
PATIENT
BATHROOM TYPE
1A
111A
PATIENT ROOM
TYPE A
PATIENT ROOM
TYPE A
PATIENT ROOM
TYPE A
DAY ROOM
PATIENT
BATHROOM TYPE
1A
108A
PATIENT
BATHROOM TYPE
1A
107A
PATIENT
BATHROOM TYPE
1A
170A
PATIENT ROOM
TYPE 'A'
PATIENT ROOM
TYPE 'A'
PATIENT
BATHROOM TYPE
1A
167A
PATIENT
BATHROOM TYPE
1A
168A
PATIENT ROOM
TYPE 'A
QUIET ROOM
TOILET
TOILET
TOILET
MED ROOM
100A
SOILED UTILITY
PATIENT ROOM
TYPE B
PATIENT
BATHROOM TYPE
1D
164A
ELEC.
PATIENT LAUNDRY
TREATMENT TEAM
ROOM
STORAGE
158A
MED ROOM
PATIENT
BATHROOM TYPE
1B
157A
PATIENT ROOM
TYPE A
PATIENT ROOM
TYPE A
PATIENT
BATHROOM TYPE
1A
156A
EXISTING STAIR
S3-1
SEMI-PRIVATE
PATIENT ROOM
SEMI-PRIVATE
PATIENT ROOM
EXISTING STAIR
S5-1
EXISTING STAIR
S2-1
PATIENT
BATHROOM TYPE
1C
147A
PATIENT
BATHROOM - TYPE
1C
148A
PATIENT ROOM
TYPE B
PATIENT
BATHROOM TYPE
1B
152A
PATIENT ROOM
TYPE B
PATIENT ROOM
TYPE B
PATIENT
BATHROOM TYPE
1B
154A
PATIENT ROOM
TYPE B
PATIENT ROOM
TYPE B
DIRTY LINEN
C109A
NURSE STATION
DAY ROOM
RECREATION
DINING
DIRTY LINEN
C105A
PATIENT ROOM
TYPE B
PATIENT
BATHROOM TYPE
1B
126A
PATIENT
BATHROOM 1B
138A
VISITOR ROOM
NURSE MANAGER
PATIENT ROOM
TYPE A
PATIENT
BATHROOM TYPE
1A
169A
COURTYARD
E
E E E E
E E
E
D1
D1 D1
D1
D1D1R1
D1
D1
D1
R1
R1
D1
D1
X1 X1
X1
X1
X…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .