This document package includes architectural drawings and specifications for repairing exterior walls on Building 15 at a Veterans Affairs medical center, as well as information on a related federal contract opportunity. The drawings depict specific areas requiring brick and mortar repair, replacement of sealants and lintels, and cleaning and painting of various materials. Accompanying notes provide repair and replacement requirements, reference applicable specifications, and specify preparation and installation procedures. The related federal contract opportunity is solicitation number 36C25022B0026 for repairing exterior walls at the location, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10. The required work includes activities shown in the architectural drawings such as brick and mortar repair and replacement, sealant replacement, and surface preparation and treatment. The response deadline and award date are not stated.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST FLOOR

846' - 11"

SECOND FLOOR

860' - 5"

ROOF

871' - 11"

61 L.F.

6 L.F.

6 S.F.

1 2 L.F.12 L.F.

10 1 S.F.

1 66 L.F.

102 S.F. (INTERIOR STAIR WALL) 10 2 S.F. (INTERIOR STAIR WALL)

P1

P2

P2 P3 P11, P4 P5

P6, P7

BRICK BASE

(SOLDIER COURSE)

P8

TYP.

TYP.21

TYP.

TYP.

TYP.

TYP.

SCALE: 1/8" = 1'-0"

15.AS402

EAST ELEVATION

NOTE:

NOT ALL KEYNOTES ARE USED ON EVERY SHEET. OTHER NOTES

NOT USED ON THIS SHEET MAY OCCUR ON OTHER SHEETS.

SCALE: NTS

P1 - PHOTO 01

SCALE: NTS

P2 - PHOTO 02

SCALE: NTS

P4 - PHOTO 04

SCALE: NTS

P5 - PHOTO 05

SCALE: NTS

P6 - PHOTO 06

SCALE: NTS

P8 - PHOTO 08

LEGEND

P1 : PHOTO 01

S.F. : SQUARE FEET

L.F. : LINEAR FEET

GENERAL CONSTRUCTION NOTES

1. AREAS SHOWN FOR REPAIR HAVE BEEN PRIORITIZED. NOT ALL DAMAGED AREAS ARE SHOWN

TO BE REPAIRED. THE INTENT OF THE DOCUMENTS ARE TO REPAIR THE EXTERIOR WALLS

WHERE THE MOST CRITICAL DAMAGE IS OBSERVED. FIELD VERIFY CONDITIONS OF AREAS

SHOWN FOR REPAIR AND NOTIFY THE COR OF ANY MAJOR DISCREPENCIES.

2. CONTRACTOR TO COORDINATE ALL WORK BETWEEN TRADES.

3. INSTALL PRODUCTS PER MANUFACTURERS WRITTEN INSTRUCTIONS.

4. ALL CONTRACTORS ARE RESPONSIBLE FOR CLEANING SITE TO THE BEST OF THEIR ABILITIES

AT THE END OF EACH WORK DAY.

5. PROTECT ALL AREAS BELOW AND SURROUNDING THE AREA UNDER CONSTRUCTION. ALL

CONTRACTORS ARE RESPONSIBLE FOR ANY DAMAGES CAUSED BY THEM DURING THE

CONSTRUCTION PROCESS. IN THE EVENT OF ANY DAMAGES CONTRACTOR IS TO CONTACT

THE VA IMMEDIATELY PRIOR TO THE END OF THE DAY OF CONSTRUCTION.

6 CONTRACTOR TO REMOVE EXTERIOR BUILDING SIGBNAGE BELOW, ABOVE, OR ADJACENT TO

THE AREA OF WORK, WHEREVER THE SIGNAGE COULD BE AFFECTED BY THE CONSTRUCTION

OPERATIONS. RE-INSTALL UPON COMPLETION OF THE WORK.

1 REMOVE, PREP AREA, AND REPLACE BRICK MORTAR JOINT, SHOWN IN LINEAR

FEET. MATCH EXISTING MORTAR JOINT EXACT.

2 REMOVE, PREP AREA, AND REPLACE EXISTING DISPLACED BRICK. IF DAMAGED

DURING CONSTRUCTION OPERATIONS, REPLACE WITH NEW BRICK. BRICK

AND MORTAR JOINT TO MATCH EXISTING EXACT.

3 REMOVE EFFLORESCENCE FROM MASONRY PRIOR TO FINAL CLEANING. AREA

SHOWN IN SQUARE FEET.

4 REMOVE, PREP AREA AND REPLACE SEALANT. SHOWN IN LINEAR FEET. REFER

TO SPECIFICATIONS.

5 REMOVE LOOSE LINTEL COMPLETE. REPLACE WITH GALVANIZED LINTEL,

PAINTED TO MATCH EXISTING. FIELD VERIFY EXACT SIZE.

6 REMOVE, PREP AREA AND REPLACE STONE MORTAR JOINT, SHOWN IN LINEAR

FEET. MATCH EXISTING MORTAR JOINT EXACT.

7 REMOVE, PREP AREA AND REPLACE SEALANT, ADD BACKER ROD. SHOWN IN

LINEAR FEET. REFER TO SPECIFICATIONS.

8 REMOVE EXISTING CONCRETE CAP AND REPLACE WITH PRECAST CONCRETE

CAP TO MATCH EXISTING EXACT. FIELD VERIFY MEASUREMENTS.

9 CLEAN, PREP, AND PAINT EXISTING STEEL LINTEL. SHOWN IN LINEAR FEET. FIELD

VERIFY MEASUREMENTS. LEAD PAINT TO BE ABATED PER SPECIFICATIONS.

10 REMOVE BROKEN OR DAMAGED BRICK. REPLACE WITH NEW BRICK. BRICK

AND MORTAR JOINT TO MATCH EXISTING EXACT.

11 REMOVE DAMAGED OR BROKEN STONE LINTEL AND REPLACE WITH NEW

STONE LINTEL. MATCH STONE AND MORTAR JOINT COMPLETE. FIELD VERIFY

STONE SIZE.

12 REMOVE DAMAGED OR BROKEN STONE SILL AND REPLACE WITH NEW STONE

SILL TO MATCH EXISTING.

13 REMOVE DAMAGED STONE. REPLACE WITH NEW STONE. NEW STONE AND

MORTAR JOINT TO MATCH EXISTING EXACT.

14 PATCH AND REPAIR LIMESTONE. MATCH EXISTING COLOR EXACT. FIELD

VERIFY.

15 REMOVE A PORTION OF THE DAMAGED LIMESTONE. PREP AND INSTALL

LIMESTONE PATCH.

16 CLEAN, PREP, AND PAINT EXPOSED STEEL REBAR. CHIP OUT CONCRETE TO

REMOVE LOOSE OR FLAKING MATERIAL. PATCH CONCRETE TO MATCH

EXISTING. FIELD VERIFY.

EXTERIOR ELEVATION NOTES

17 THOROUGHLY CLEAN LIMESTONE. REFER TO SPECIFICATIONS.

18 PATCH / REPAIR CONCRETE. PREP DAMAGED AREA AS NEEDED INCLUDING

REMOVING CONCRETE TO PROVIDE A PROPER SURFACE TO ACCEPT THE

CONCRETE PATCH MATERIAL. 1" "V" SHAPE (ROUGH) MINIMUM AREA

REQUIRED.

19 INSTALL SEALER TO CONCRETE TO PROTECT FROM SALT. FOLLOW

MANUFACTURER INSTRUCTIONS FOR APPLICATION REQUIREMENTS.

20 CUT IN 1/2" EXPANSION JOINT THROUGH BRICK VENEER. SEAL JOINT WITH

SEALANT PER SPECIFICATIONS.

21 REMOVE (ABATE PER SPECIFICATIONS 02 08333.13) WINDOW PERIMETER

SEALANT / CAULK AT ALL EXTERIOR OPENINGS, DOORS AND WINDOWS 100%.

ALL OPENINGS WHETHER OR NOT THE NOTE IS SHOWN.

SPECIFICALLY THE JOINT WHERE THE WINDOW / DOOR MEETS THE EXTERIOR

CLADDING (BRICK / STONE). REPLACE WITH NEW AS SPECIFIED.

SCALE: NTS

P3 - PHOTO 03

SCALE: NTS

P7 - PHOTO 07

SCALE: NTS

P9 - PHOTO 09

SCALE: NTS

P11 - PHOTO 11

SCALE: NTS

P10 - PHOTO 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

All Concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural

Design, Inc. and shall not be used for any purpose without prior expressed written consent. The Owner shall be permitted to retain copies for information and reference.

Viridian Architectural Design, Inc.

2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803

PH: 260.424.4830

www.viridian-design.net

FINAL BID

DOCUMENTS

OF06 38

C :\U se rs

\A ad le r\D es kt op \re vi t l oc al

\6

-2 1-

8_

B1 5_

C

EN

TR

AL

_R

_a ad le r.r vt 8/

9/

0:

:2

AM

15.AS402

BUILDING 15 EAST ELEVATION REPAIR EXTERIOR WALLS,

MARION

MARION VAMC

610-21-208

08/09/2021 TWT JMP

Building 15

Revisions: Date:

Sheets
15.AS101 - BUILDING 15 FIRST FLOOR PLAN
15.AS401 - BUILDING 15 NORTH ELEVATION
15.AS402 - BUILDING 15 EAST ELEVATION
15.AS403 - BUILDING 15 SOUTH ELEVATION
15.AS404 - BUILDING 15 WEST ELEVATION
GI001 - COVER SHEET
GI002 - ARCHITECTURAL - ABBREVATIONS AND SYMBOLS
GI003 - AREA LOCATION PLAN