N1187304 Cinci VA Replace Hospital Steam Heating Systems Phase 2 Ltd LP Sampling Analysis Report 040419.pdf
PDF 538 KB Posted
- Attached to
- 36C25020B0027 - Z1DA--Replace Steam Heating Systems Federal contract opportunity
- Solicitation number
- 36C25020B0027
About this file
This solicitation package is for replacement of steam heating systems at the Cincinnati VA Medical Center in Cincinnati, Ohio. Terracon Consultants conducted limited lead paint sampling of prominent painted surfaces that may be impacted by the planned renovation work. The sampling identified lead content above the detection limit in a yellow painted pipeline. Contractors bidding or working on the project that may disturb surfaces with lead paint will need to comply with applicable regulations for lead safety. The solicitation period for project number 539-18-102 closes approximately 30 days from the posting date of April 4, 2019. Offerors are advised to monitor the Federal Business Opportunities website for additional details and amendments.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25020B0027 0003.docx | DOCX document | |
| N1187304 Cinci VA Replace Hosiptal Steam Systems Phase 2 Asbestos Survey Report Final.pdf | ||
| 36C25020B0027 0002.docx | DOCX document | |
| 36C25020B0027 0001.docx | DOCX document | |
| 36C25020B0027 0001.docx | DOCX document | |
| 36C25020B0027-004.pdf | ||
| 36C25020B0027-005.pdf | ||
| 36C25020B0027-003.pdf | ||
| 36C25020B0027-002.docx | DOCX document | |
| 36C25020B0027-006.docx | DOCX document | |
| 36C25020B0027-007.docx | DOCX document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Terracon Consul tants, Inc., 611 Lunken Park Dr ive, Cincinnat i , OH 45226 P (513) 321-5816 terracon.com
April 4, 2019
Levin Porter Associates Inc.
3011 Newmark Drive Miamisburg, Ohio 45342
Attn: Mr. J. William Williams, AIA President T: (937) 224-1931 E: bwilliams@levin-portar.com
Re: Limited Paint Sampling for Lead-Content Analysis VA Project: Replace Hospital Steam Heating Systems Phase 2 VA Project No. 539-18-102 Cincinnati VA Medical Center 3200 Vine Street Cincinnati, Ohio 45220 Terracon Project No. N1187304
Dear Mr. Williams:
Terracon Consultants, Inc. (Terracon) appreciates the opportunity to submit this letter report to Levin Porter Associates Inc. (Client) regarding the lead analytical results for limited paint sampling conducted for the above-referenced project at the Cincinnati VA Medical Center (CVAMC). We understand that this survey was requested for the purpose of a planned renovation regarding to impacts to various hospital steam systems at various locations throughout the hospital.
Terracon representatives Mr. Joshua Vogel and Mr. Lemuel Weyer conducted the limited paint sampling. Sample collection was performed using a clean straight-edge razor to remove paint from designated surfaces. Collected paint samples were placed in sealable containers, labeled with unique sample numbers, and submitted under chain of custody to International Asbestos Testing Laboratories (IATL) of Mount Laurel, New Jersey. Paint chip samples were submitted for analysis by Atomic Absorption Spectroscopy (AAS) per EPA Method SW846/3050B/7420M. IATL is accredited for lead in paint analysis by the American Industrial Hygiene Association’s (AIHA®) Environmental Lead Laboratory Accreditation Program (ELLAP), accreditation number 100188.
Lead Paint Analytical Results Summary Terracon collected a total of one (1) paint sample for lead-content analysis from within the renovation project area. A sample summary which includes the sample description and analytical result is attached; the result is presented in parts per million (ppm) lead. The sample collected was identified by laboratory analysis to contain lead above the detection limit. The laboratory analytical report and sample chain of custody are also attached.
Lead-Containing Paint Sampling Replace Hospital Steam Heating Systems Phase 2 ■ CVAMC April 4, 2019 ■ Terracon Project No. N1187304
Terracon Consul tants, Inc., 611 Lunken Park Dr ive, Cincinnat i , OH 45226 P (513) 321-5816 terracon.com
Occupational Safety and Health Administration (OSHA) standard, 29 Code of Federal Regulations (CFR) 1926.62 (Lead in Construction), does not reference a specific concentration of lead in a surface coating for applicability of the aforementioned regulation. The requirements under OSHA 29 CFR 1926.62 are applicable to any concentration of lead found above analytical limit of detection (LOD). When disturbed, paints containing lead in any concentration represent an airborne exposure hazard that could exceed the OSHA legally enforceable action level (AL) or permissible exposure limit (PEL). Contractors that bid or conduct work activities that will disturb surfaces with analytically-confirmed LCP should be made aware of those so that they can plan for proper compliance with applicable federal and state regulations, and any applicable Client specifications. Additionally, contractors should be aware that any untested paint surfaces should be assumed to also contain lead unless sampling and analysis refute lead-content.
This sampling event was conducted as per the direction and request of the Client. The sampling was of a limited nature specific to prominent and readily accessible painted surfaces and may not have included every painted surface. The sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings and recommendations expressed in this letter report are based on conditions observed during the sampling event. This letter report has been prepared on behalf of and exclusively for use and reliance by the Client and is not a bidding document. Contractors or consultants reviewing this limited sampling report must draw their own conclusions regarding whether further investigation or remediation is deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third-parties supplying information, which may have been used in the preparation of this report. No warranty, express or implied, is made.
Terracon appreciates the opportunity to provide this service to Levin Porter Associates Inc. If you have questions regarding this letter report or if we can be of further service, please contact the undersigned at (513) 321-5816.
Sincerely, Terracon Consultants, Inc.
Joshua Vogel Joseph Tussey. CHMM Project Manager Senior Associate/Group Manager
Attachments: Sample Summary Table Laboratory Analytical Report
April 4, 2019 ■ Terracon Project No. N1187304
Attachment 1: Sample Summary Table
April 4, 2019 ■ Terracon Project No. N1187304
Terracon Sample # Component Paint
Color (surface) Substrate Sample Location Results (ppm lead)
L-01 Pipeline Yellow Fiberglass North End of C003B 60,000
< = less than limit of detection (LOD)
April 4, 2019 ■ Terracon Project No. N1187304
Attachment 2: Laboratory Analytical Report
Lab No.: 6742650 Client No.: L-01
Description: Yellow Paint Location: North End Of C003B-Fiberglass Pipe Line
Result (% by Weight): 6.0 Result (ppm): 60000 Comments:
Laboratory Director
Approved By:
Date Analyzed:
3/18/2019Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Arnesha Brewer
03/25/2019 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
3/25/2019Report Date:
Report No.: 585789 - Lead Paint Project: CVAMC-Steam Lines-Phase 2 Project No.: N1187304
LEAD PAINT SAMPLE ANALYSIS SUMMARY
Client: TER940
Dated : 3/25/2019 1:53:54 Page 1 of 2
Appendix to Analytical Report:
Customer Contact:
Method: ASTM D3335-85a, US EPA SW846 3050B:7000B
This appendix seeks to promote greater understanding of any observations, exceptions, special instructions, or circumstances that the laboratory needs to communicate to the client concerning the above samples. The information below is used to help promote your ability to make the most informed decisions for you and your customers.
Please note the following points of contact for any questions you may have.
iATL Customer Service: customerservice@iatl.com iATL Office Manager:wchampion@iatl.com iATL Account Representative: Cassie Doherty Sample Login Notes: See Batch Sheet Attached Sample Matrix: Paint Exceptions Noted: See Following Pages
General Terms, Warrants, Limits, Qualifiers:
General information about iATL capabilities and client/laboratory relationships and responsibilities are spelled out in iATL policies that are listed at www.iATL.com and in our Quality Assurance Manual per ISO 17025 standard requirements. The information therein is a representation of iATL definitions and policies for turnaround times, sample submittal, collection media, blank definitions, quantification issues and limit of detection, analytical methods and procedures, sub-contracting policies, results reporting options, fees, terms, and discounts, confidentiality, sample archival and disposal, and data interpretation.
iATL warrants the test results to be of a precision normal for the type and methodology employed for each sample submitted. iATL disclaims any other warrants, expressed or implied, including warranty of fitness for a particular purpose and warranty of merchantability. iATL accepts no legal responsibility for the purpose for which the client uses test results. Any analytical work performed must be governed by our Standard Terms and Conditions. Prices, methods and detection limits may be changed without notification. Please contact your Customer Service Representative for the most current information.
This confidential report relates only to those item(s) tested and does not represent an endorsement by NIST-NVLAP, AIHA LAP LLC, or any agency of local, state or province governments nor of any agency of the U.S. government.
This report shall not be reproduced except in full, without written approval of the laboratory.
Information Pertinent to this Report:
Analysis by ASTM D3335-85a by AAS
Certification:
- National Lead Laboratory Program (NLLAP): AIHA-LAP, LLC No. 100188
- NYSDOH-ELAP No. 11021
Regulatory limit is 0.5% lead by weight (EPA/HUD guidelines). Recommend multiple sampling for all samples less than regulatory limit for confirmation.
All results are based on the samples as received at the lab. iATL assumes that appropriate sampling methods have been used and that the data upon which these results are based have been accurately supplied by the client.
Method Detection Limit (MDL) per EPA Method 40CFR Part 136 Apendix B.
Reporting Limit (RL) based upon Lowest Standard Determined (LSD) in accordance with AIHA-ELLAP policies.
LSD=0.2 ppm MDL=0.005% by weight. RL= 0.010% by weight (based upon 100 mg sampled).
Disclaimers / Qualifiers:
There may be some samples in this project that have a "NOTE:" associated with a sample result. We use added disclaimers or qualifiers to inform the client about something that requires further explanation. Here is a complete list with highlighted disclaimers pertinent to this project. For a full explanation of these and other disclaimers, please inquire at customerservice@iatl.com.
* Insufficient sample provided to perform QC reanalysis (<200 mg) ** Not enough sample provided to analyze (<50 mg) *** Matrix / substrate interference possible.
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon 611 Lunken Park Drive Cincinnati OH 45226
3/25/2019Report Date:
Report No.: 585789 - Lead Paint Project: CVAMC-Steam Lines-Phase 2 Project No.: N1187304
Client: TER940
Page 2 of 2Dated : 3/25/2019 1:53:54
| COA_585789.pdf |
| DAILY LEAD QC 3-25-19.pdf |
| 585789.pdf |
| 2019-04-04T10:08:16-0400 | |
| Vogel, Joshua |
| 2019-04-04T10:11:06-0400 | |
| Tussey, Joe A |
File details come from the government source that posted it. Updated .