36C25018B0425-00001016.pdf

PDF 850 KB Posted

Attached to
Correct FCA Deficiencies FTD Exterior Deficiencies 539-19-203
Solicitation number
36C25018B0425
Issued by

About this file

36C25018B0425 00001 A-201 - EXTERIOR ELEVATIONS.pdf

View the file

Other files

File Type Posted
36C25018B0425-00001017.pdf PDF
36C25018B0425-00001015.docx DOCX document
36C25018B0425-00001019.docx DOCX document
36C25018B0425-00001018.pdf PDF
36C25018B0425-006.docx DOCX document
36C25018B0425-005.pdf PDF
36C25018B0425-007.docx DOCX document
36C25018B0425-008.docx DOCX document
36C25018B0425-004.pdf PDF
36C25018B0425-003.docx DOCX document
36C25018B0425-009.pdf PDF
36C25018B0425-002.docx DOCX document
36C25018B0425-001.docx DOCX document
36C25018B0425-000.docx DOCX document
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

64-FIRST FLOOR

844' - 5"

64-BASEMENT

833' - 11"

64-THIRD FLOOR

867' - 4"

123456789101213151617181920212223

64-ROOF

878' - 9 1/2"

64-SECOND

FLOOR

855' - 10 1/2"

64-TO FOOTING

832' - 5"

64-MECH

BASEMENT

830' - 11"

142627 2930

L-W1 L-W2 L-W3 L-W5L-W4 L-W6 L-W7 L-W8 L-W9 L-W10

2 2

2 2 2 2 2 2

3 3 3 3 3

3 3

4 4

44 4

4 4

7 7 7 7 7 7 7 77

4 44

64-FIRST FLOOR

844' - 5"

64-BASEMENT

833' - 11"

64-THIRD FLOOR

867' - 4"

1 2 3 4 5 6 7 8 9 10 12 13 15 16 17 18 19 20 21 22 23

64-ROOF

878' - 9 1/2"

64-SECOND

FLOOR

855' - 10 1/2"

64-TO FOOTING

832' - 5"

64-MECH

BASEMENT

830' - 11"

14 26 2729 30

L-E1 L-E2 L-E3 L-E4 L-E5 L-E6 L-E7 L-E8 L-E9 L-E10 L-E11 L-E12 L-E13 L-E14 L-E15 L-E16 L-E17 L-E18 L-E19

2 2 2 2 2 2 2 2 2 2

3 3 3 3 3 3 3 3 33

4 4 4 4

7 7

Elevation Key Notes:

(All may not apply to this sheet)

Drawing Title

Approved: Project Director

Location

Building Number

Project Title

Checked DrawnDate

Project No.

Drawing Number

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o t th re e in c h e s o n e fo o t

F E

D C

B A

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A

VA Project No.

ARCHITECT/ENGINEERS:CONSULTANTS:

Office of Construction and Facilities Management

PFB Architects,Inc.

9461 Kenwood Road

Cincinnati, Ohio 45242

(513) 861 3200

Heapy Engineering 1400 West Dorothy Lane Dayton OH 45409

(937) 224 0861

PFB Project No.CORRECT FCA DEFICIENCIES

- FTD EXTERIOR

DEFICIENCIES

10/27/2017

EXTERIOR ELEVATIONS

A-201

#539-19-203

Fort Thomas, KY

PFB PFB

Scale: 3/32" = 1'-0"2

WEST ELEVATION

Scale: 3/32" = 1'-0"1

EAST ELEVATION

1 REMOVE EXISTING DIRECT EXTERIOR FINISH SYSTEM AND REPLACE WITH NEW DIRECT

EXTERIOR FINISH SYSTEM TO MATCH EXISTING. SEE SPEC SECTION 07 24 00.

2 REMOVE EXISTING LOUVER BELOW FIRST FLOOR WINDOWS AND REPLACE WITH NEW

LOUVER TO MATCH EXISTING SIZE AND FREE AREA. COORDINATE SCHEDULING WITH VA

TO ALLOW ROOMS TO BE VACATED AS NEEDED FOR COMPLETION OF WORK.

CONTRACTOR TO NOTE: NUMBER OF ROOMSVACATED FOR THIS PURPOSE MAY BE AS

FEW AS ONE AT A TIME. PROVIDE EXTERNAL CONDENSATE DRAIN KIT (SIMILAR OR

EQUAL TO FRIEDRICH PXDR10) WITH PLASTIC TUBING AS NEEDED. LOUVER TO BE

DARK BRONZE FINISH.

3 REPAIRED DAMAGED SECTION OF DIRECT EXTERIOR FINISH SYSTEM. APPROXIMATE

TOTAL QUANTITY 150 SF.

4 AFTER COMPLETION OF DIRECT EXTERIOR FINISH SYSTEM REPAIRS AND REPLACEMENT,

PAINT ALL NEW AND EXISTING DIRECT EXTERIOR FINISH SYSTETM. PAINT TO BE EXTRIOR

LATEX, COLOR TO MATCH EXISTING.

7 EXISTING COPPER CONDUCTOR HEAD AND DOWNSPOUT TO BE REPAIRED, CLEANED,

AND COATED TO PROTECT FROM CORROSION. REPAIR AND SECURE ANY LOOSE

CONNECTIONS OR SEPARATED SEAMS AS NEEDED. CLEAN EXISTING PATINA FROM ALL

COPPER COMPONENTS TO RESTORE ORIGINAL FINISH. COAT WITH CORROSION

INHIBITOR TO PREVENT WEATHERING OF RESTORED COPPER. REFER TO SPECIFICATION

SECTION 05 01 70. NON-COPPER COMPONENTS AT BASE OF BUILDING TO BE

PAINTED TO MATCH ADJACENT WALL SURFACE.

9 EXISTING CAULK AT THIS LOUVER CONTAINS ASBESTOS. SEE SPECIFICATION SECTION

02 82 13.31.

Revision s

Date

2 Bid Clarification Items 5-16-2018

1 Revision 1 3-28-2018

Sheets
A-201 - EXTERIOR ELEVATIONS
AS-101 - ARCHITECTURAL SITE PLAN

File details come from the government source that posted it.