36C24918Q9586

PAGE 1 OF

1. REQUISITION NO.

2. CONTRACT NO.

3. AWARD/EFFECTIVE DATE

4. ORDER NO.

5. SOLICITATION NUMBER

6. SOLICITATION ISSUE DATE

a. NAME

b. TELEPHONE NO. (No Collect Calls)

8. OFFER DUE DATE/LOCAL

TIME

9. ISSUED BY

CODE

10. THIS ACQUISITION IS

UNRESTRICTED OR

SET ASIDE:

% FOR:

SMALL BUSINESS

HUBZONE SMALL

BUSINESS

SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

WOMEN-OWNED SMALL BUSINESS

(WOSB) ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

EDWOSB

8(A)

NAICS:

SIZE STANDARD:

11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

SEE SCHEDULE

12. DISCOUNT TERMS

13a. THIS CONTRACT IS A

RATED ORDER UNDER

DPAS (15 CFR 700)

13b. RATING

14. METHOD OF SOLICITATION

RFQ

IFB

RFP

15. DELIVER TO

CODE

16. ADMINISTERED BY

CODE

17a. CONTRACTOR/OFFEROR

CODE

FACILITY CODE

18a. PAYMENT WILL BE MADE BY

CODE

TELEPHONE NO.

DUNS:

DUNS+4:

PHONE:

FAX:

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN OFFER 18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK BELOW IS CHECKED

SEE ADDENDUM

19.

20.

21.

22.

23.

24.

ITEM NO.

SCHEDULE OF SUPPLIES/SERVICES

QUANTITY

UNIT

UNIT PRICE

AMOUNT

(Use Reverse and/or Attach Additional Sheets as Necessary)

25. ACCOUNTING AND APPROPRIATION DATA

26. TOTAL AWARD AMOUNT (For Govt. Use Only) 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED. ADDENDA

ARE

ARE NOT ATTACHED.

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA

ARE

ARE NOT ATTACHED

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN _______________

29. AWARD OF CONTRACT: REF. ___________________________________ OFFER

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

DATED ________________________________. YOUR OFFER ON SOLICITATION

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED

SET FORTH HEREIN IS ACCEPTED AS TO ITEMS:

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER) 30b. NAME AND TITLE OF SIGNER (TYPE OR PRINT) 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER (TYPE OR PRINT) 31c. DATE SIGNED

AUTHORIZED FOR LOCAL REPRODUCTION

(REV. 2/2012)

PREVIOUS EDITION IS NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.212

7. FOR SOLICITATION

INFORMATION CALL:

STANDARD FORM 1449

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

36C24918Q9586 08-14 -2018 David Milner 615-225-6543 08-31-2018 12:00pmCT 90C Department of Veterans Affairs Network Contracting Office 9 1639 Medical Center Parkway Suite 400 Murfreesboro TN 37129 X X 811310 $7.5 Million N/A X Department of Veterans Affairs Lexington VAMC 1101 Veterans Drive Lexington KY 40502 90C Department of Veterans Affairs Network Contracting Office - 9 1639 Medical Center Parkway Suite 400 Murfreesboro TN 37129

90C FSC e-Invoice Payment http://www.fsc.va.gov/fsc/einvoice.asp Invoice Setup Information 1-877-489-6135 Invoice must be submitted electronically

Setup 1-877-489-6135 The Lexington VAMC Leestown and Cooper Divisions require a contractor to provide inspection and maintenance service on 23 passenger elevators, 1 freight elevator, and 4 service elevators per the Statement of Work located Section B.2.

PLEASE NOTE: THIS REQUIREMENT IS A SDVOSB SET ASIDE.

THE CONTRACTOR MUST BE REGISTERED IN VETBIZ.GOV TO BE

CONSIDERED FOR AWARD.

See Addendum to 52.212-1 for instructions on submitting questions and quotes. Quoters shall address Limitations on Subcontracting and provide past performance history.

X X Table of Contents

SECTION A1
A.1 SF 1449 SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS1
SECTION B - CONTINUATION OF SF 1449 BLOCKS3
B.1 CONTRACT ADMINISTRATION DATA3
B.2 ELEVATOR MAINTENANCE & REPAIR SERVICE LEXINGTON VAMC4
B.3 PRICE/COST SCHEDULE19
ITEM INFORMATION19
SECTION C - CONTRACT CLAUSES23
C.1 52.252-2 CLAUSES INCORPORATED BY REFERENCE (FEB 1998)23
C.2 52.216-18 ORDERING (OCT 1995)23
C.3 52.216-19 ORDER LIMITATIONS (OCT 1995)24
C.4 52.216-21 REQUIREMENTS (OCT 1995)24
C.5 52.217-8 OPTION TO EXTEND SERVICES (NOV 1999)25
C.6 52.217-9 OPTION TO EXTEND THE TERM OF THE CONTRACT (MAR 2000)25
C.7 SUPPLEMENTAL INSURANCE REQUIREMENTS25
C.8 VAAR 852.203-70 COMMERCIAL ADVERTISING (MAY 2018)26
C.9 VAAR 852.219-10 VA NOTICE OF TOTAL SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS SET-ASIDE (JUL 2016)(DEVIATION)26
C.10 852.219-74 LIMITATIONS ON SUBCONTRACTING MONITORING AND COMPLIANCE. (JUL 2018)27
C.11 VAAR 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS (NOV 2012)28
C.12 VAAR 852.237-70 CONTRACTOR RESPONSIBILITIES (APR 1984)29
C.13 52.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS—COMMERCIAL ITEMS (JAN 2018)29
SECTION D - CONTRACT DOCUMENTS, EXHIBITS, OR ATTACHMENTS37
D.1 WAGE DETERMINATION 68-005537
SECTION E - SOLICITATION PROVISIONS39
E.1 52.209-7 INFORMATION REGARDING RESPONSIBILITY MATTERS (JUL 2013)39
E.2 52.252-1 SOLICITATION PROVISIONS INCORPORATED BY REFERENCE (FEB 1998)42
E.3 52.216-1 TYPE OF CONTRACT (APR 1984)42
E.4 52.217-5 EVALUATION OF OPTIONS (JUL 1990)42
E.5 52.233-2 SERVICE OF PROTEST (SEP 2006)43
E.6 52.237-1 SITE VISIT (APR 1984)43
E.7 VAAR 852.233-70 PROTEST CONTENT/ALTERNATIVE DISPUTE RESOLUTION (JAN 2008)43
E.8 VAAR 852.233-71 ALTERNATE PROTEST PROCEDURE (JAN 1998)44
E.9 VAAR 852.270-1 REPRESENTATIVES OF CONTRACTING OFFICERS (JAN 2008)44
E.10 52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS—COMMERCIAL ITEMS (NOV 2017)45

SECTION B - CONTINUATION OF SF 1449 BLOCKS

B.1 CONTRACT ADMINISTRATION DATA

1. Contract Administration: All contract administration matters will be handled by the following individuals:

a. CONTRACTOR:

b. GOVERNMENT: Contracting Officer 36C249 Craig S. Ziegemeier Department of Veterans Affairs Network Contracting Office 9 1639 Medical Center Parkway Suite 400 Murfreesboro TN 37129

2. CONTRACTOR REMITTANCE ADDRESS: All payments by the Government to the contractor will be made in accordance with:

[X]
52.232-33, Payment by Electronic Funds Transfer—System For Award Management, or
[]
52.232-36, Payment by Third Party

3. INVOICES: Invoices shall be submitted in arrears:

a. Quarterly[]
b. Semi-Annually[]
c. Other[X] Monthly in Arrears

4. GOVERNMENT INVOICE ADDRESS: All Invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests.

FSC e-Invoice Payment http://www.fsc.va.gov/fsc/einvoice.asp Invoice Setup Information 1-877-489-6135 Invoice must be submitted electronically

ACKNOWLEDGMENT OF AMENDMENTS: The offeror acknowledges receipt of amendments to the Solicitation numbered and dated as follows:

AMENDMENT NO
DATE

B.2 ELEVATOR MAINTENANCE & REPAIR SERVICE LEXINGTON VAMC

1. SCOPE OF WORK

A. Furnish inspection and maintenance service on all twenty-three (23) passenger elevators, one (1) freight elevators, four (4) service elevators identified in the Schedule of Elevators.

B. Scope of Work

1. The Contractor shall obtain all necessary licenses and/or permits required to perform the work.

2. The Contractor shall furnish all material, labor, lubricants, hydraulic fluids, supervision, tools, shipping, travel and equipment necessary to provide full maintenance services, including all adjustments, tests, parts replacement and repairs necessary to keep the elevators in continuous use at their initial performance ability (same speed, capacity, safety and efficiency) as originally specified by the equipment manufacturer as modified thereafter. All travel costs associated with the performance of this contract are the responsibility of the contractor and are provided at no additional cost to the Government as part of this contract. Travel costs are defined as but are not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc.

3. All adjustments, repairs and modifications, must be in conform to the manufacturer guidelines and/or the following industry standards, as applicable, whichever is more stringent:

· ASME A17.1 Safety Code for Elevators and Escalators, latest edition

· ASME A17.2 Inspectors’ Manual for Elevators and Escalators, latest edition

· ASME A17.3 Safety Code for Existing Elevators and Escalators, latest edition

· ANSI/NFPA 70 National Electric Code, latest edition

· Manufacturer’s requirements and specifications on inspection, maintenance, and operation of each elevator model

4. Contractor shall be qualified on all systems and have in his possession throughout the term of the contract all diagnostic equipment necessary to fully maintain, test, repair, adjust or reprogram the systems.

5. The Contractor shall post a check chart for each elevator in each machine room in a conspicuous place. This check chart shall list each elevator component-showing schedule of manufacturers recommended frequency of inspection of each component on a weekly, semi-annually, annually or other frequency. Entries shall be to indicate the status of schedule items of maintenance work performed. The check chart shall be kept up to date at all times and must be initialed and dated by the Contractors employee to indicate that the work has been accomplished. Check chart shall be available for review at the CORs request and the Contractor shall physically show the COR the completed work on request.

6. Safety tests and other tests and inspections shall be performed by the Contractor. Contractor shall perform all safety tests and other tests and inspections as recommended and required by ASME A17.1 LATEST EDITION AND ANSI/ASME A17.2 LATEST EDITION.

7. Contractor shall be required to attach tags after testing as specified by Code, such as at the governor-releasing carrier, and oil buffer, etc.

8. Any repairs or adjustments necessary to complete a test and return the elevator to service shall be performed by the Contractor at no additional expense to the Medical Center.

9. After completion of the required tests, submit document with information to the COR.

10. All elevators provided with firefighter's service shall be subjected monthly to Phase I recall and a minimum of one floor operation on Phase II to assure the system is maintained in proper operating order in accordance with A17.1 Code. A written record of findings on the operation shall be made by the Contractor and kept on the premises of said operation. Testing shall be done on weekend, holidays or the hours before 6:30 AM or after 6:30 PM, at no additional cost to the Medical Center.

11. All tests or inspections that will remove the elevator from normal operation shall be scheduled in advance with the COR.

C. An adequate supply of spare parts shall be maintained at all times to ensure prompt preventive maintenance and repair services.

D. Contractor shall have all maintenance tickets signed by the COR. This task shall be completed during normal business hours. If maintenance is performed outside of normal business hours, maintenance tickets will be signed by the COR the following business day.

E. The following performance levels shall be maintained at all times:

1. Contract speed and brake to brake flight time shall be maintained as originally installed and adjusted.

2. Leveling accuracy shall be maintained at all times.

3. Opening and closing times, door close torques of all cars shall at all times be maintained within the limits of ASME A17.1 Code with a minimum of stand open time consistent with traffic demands at each floor.

4. Door reversal on all elevators equipped with mechanical safety shoes shall always be initiated with the stroke of the shoe. Ensure all electric eyes or door detectors are working at all times.

5. Variable car and hall door open times shall be maintained in accordance with original field adjustments. Deviations from this will not be permitted unless requested and/or approved by this COR.

6. Upon satisfactory completion of this or subsequent readjustments, a computerized elevator analyzer or similar type event recorder shall be utilized to accurately record the hall waiting time at each landing and other data necessary to establish that the system is operating at peak efficiency. Results shall be submitted and be labeled as to floor, time, date and identification of all other data and shall be delivered together with an analysis of the tapes/disks to the COR.

F. The Contractor shall furnish all labor and supplies, parts and materials necessary to regularly and systematically clean, examine, adjust, lubricate as required and if conditions warrant, repair or replace, as follows:

1. Machine, worm, gear, thrust bearings, drive sheave, drive sheave shaft bearings, brake pulley, brake coil, brake contact, brake linings and component parts.

2. Machine motor, motor generator, motor windings, rotating element, commutator, brushes, brush holders and bearings.

3. Controller, selector and dispatching equipment, all relays, solid state components, resistors, condensers, transformers, contacts, leads, dashpots, time devices, computer devices, CRT devices, selector tape or wire and mechanical and electrical driving equipment.

4. Governor, governor ropes, governor sheave and shaft assembly, bearings, contacts, and governor jaws.

5. Deflector or secondary sheave, bearings, car and counterweight buffers, car and counterweight guide rails, top and bottom limit switches, governor tension sheave assembly, compensating sheave assembly, counterweight guide shoes including rollers or gibs.

6. Hoistway door interlocks, hoistway door hangers, bottom door guides and auxiliary door closing devices.

7. Automatic power operated door operator, car door hanger, car door contact, door protective devices, load weighing equipment, car frame, car safety mechanism, platform, wood platform flooring, car guide shoes including gibs and rollers.

8. Car operating panel(s) and equipment, hall lanterns, hall buttons and signal devices.

9. Cab Lighting

10. Where applicable to hydraulic elevators include cylinder head, plunger exposed surfaces, plunger gland and packing, pumps, exposed piping, fittings and flexible pipe connections, operating controls, check and relief valves, valves, gages and tanks.

11. All parts and materials shall be of the original manufacturers design and specification, or equal thereto. All lubricants shall be as recommended by the manufacturer.

G. The Contractor shall also:

1. Examine monthly all safety devices and governors and conduct an annual no load safety test and each fifth year perform a full load, full speed test of safety mechanism, overhead speed governors, car and counterweight buffers. If required, the governor will be calibrated and sealed for proper tripping speed.

2. Semi-annually equalize the tension on all hoisting ropes, repair and replace conductor cables and hoist way and machine room wiring.

3. Keep car emergency light units in an operable condition at all times, test special emergency (fireman's service) service and emergency power circuits, where provided in accordance with Code requirements.

4. Furnish lubricants specified to the various lubrication needs.

5. Maintain a supply of contacts, coils, leads, brushes, lubricants, wiping cloths and other minor parts in each machine room for the performance of routine preventative maintenance.

6. Maintain a complete set of current, legible schematic wiring diagrams in each elevator machine room for each elevator contained therein. To the extent that any of the required schematic wiring diagrams are not available at the time of contract award, it shall be the responsibility of the Contractor to provide same at no cost to the Medical Center.

7. The Contractor shall maintain a full, legible service log in each machine room and a complete, orderly chronological file including drawings, complete part lists, and copies of all service reports. Service log shall contain a printout of the controller fault log, monthly to prevent loss of data, and repeated faults shall be explained. The log shall list the date and time of all maintenance service performed. Each trouble call shall be fully described, including the nature of the call necessary service performed and any parts replaced. Service file shall be made available for inspection upon request, and a copy of the complete file furnished to VAMC during the first week of the last month of the normal contract term.

8. The Contractor shall maintain a separate maintenance record on each elevator. The maintenance record shall be kept in the elevator equipment room and shall be readily available for inspection by the COR or designee. The maintenance record is the property of the government and shall be turned over to the Government at the end of the contract. The maintenance record shall be a chronological file that includes the following information:

a) Date.

b) Nature of work (i.e. PMI or call back).

c) Description of work performed (contractor should be brief and concise).

d) Any indication of problems experienced.

e) Initial or signature of mechanics performing work.

9. The Contractor shall instruct his personnel that when they perform work under this contract, they shall comply with the following procedures:

a) Upon arrival at the station, the Contractor shall check in with the Electrical Shop Foreman or his designee so that the VAMC will be aware of the Contractors presence at the facility at all times. b) Upon each departure, Contractor shall serve notice of disposition of work to the COR or designee. In addition, the contractor shall furnish the Electrical Shop Foreman or his designee a copy of a work order, service sheet or other such written notification of services performed. Such reports shall include the following information:

· Name and address of contractor

· Name of contractor employee(s) performing the work

· Date(s) work performed and hours spent.

· Brief description of work performed, including PMI’s and identification of equipment worked on.

· Signature of contractor’s employee(s) and signature of Electrical Shop Foreman or designee.

· If the report is not submitted it will indicate that no inspection or maintenance was performed and payment may be withheld and/or delayed.

10. Semi-annually clean hoist way including all equipment located in or moving through the hoist way, car top, car sling, safeties, appliances, pits, sills, door tracks and hangers. Clean and paint as needed machine room floors.

H. Maintenance for the card reader system is not part of the maintenance requirement.

I. An elevator is not considered satisfactory if it requires excessive maintenance and repair to remain operational. If the elevator is not functioning in accordance with manufacturers specifications or in the opinion of the COR requires excessive maintenance and repair, the elevator shall be removed from service and components replaced to return the elevator back to satisfactory performance. All parts and labor shall be warranted for one year after the date of installation. Any components which have suffered life cycle reduction or damage due to repeated failures shall be warranted.

J. Work excluded: The following work is specifically excluded from this contract.

1. Repair or replacement made necessary due to negligence or misuse of the equipment by persons other than the Contractor, his representatives or his employees. The COR or designee must approve in advance any extra charge work attributed to vandalism or misuse. No invoice will be paid without prior approval. Any repairs due to misuse or negligence shall be billed according to the labor rate specified in the pricing schedule. Parts will be billed at actual invoiced cost.

2. Installation of new attachments, which may be required or recommended by insurance agencies or Government Authorities.

3. Repairs or replacement of cab enclosure, hoistway enclosures, door frames and sills, machine room lighting, cab tile or carpet.

4. Replacement of underground hydraulic piping or hydraulic cylinder.

5. For the purpose of clarification, any item not specifically excluded shall be considered the Contractors responsibility.

K. Except for emergency callback service, the Contractor shall perform all work during regular working hours of regular working days 8:00 a.m. to 4:30 p.m. excluding Federal holidays, unless specifically instructed otherwise by the COR.

1. Emergency Callback Service shall be provided 24 hours a day, seven days per week, as requested by the COR. The hourly labor rate quoted shall be used.

L. The Contractor shall provide callback services for each elevator as follows: Callback service is defined as requests for each individual elevator, either during or after normal working hours, to correct any elevator problem or condition, which needs attention. Callbacks during normal working hours consists of responding to VAMC to each individual elevator service call and take corrective action at the site within 1 hour for passenger entrapments, 2 hours for all other service calls. Callbacks are not to take time away from preventive maintenance and other requirements required under this contract, equipment malfunctions shall be corrected the same day that the service call was issued. If circumstances beyond the contractors control preclude resolution of the problem that day, the COR must be notified with an explanation of the delay.

1. The Contractor shall have each service ticket for each service call signed by COR or designee. The service ticket shall identify the elevator identifier, piece of equipment, description of problem, description of corrective measures taken and date and time unit was returned to regular service. Service tickets for a labor hourly rate or extra charge work must be signed and a copy left with the COR. Failure to do so will result in non-payment for extra charge work.

2. Emergency service or repairs authorized by the COR, which occur after the normal hours of operation, shall be accomplished at the labor hourly rates specified in the pricing schedule. The Medical Center will be responsible for premium portion of the labor hourly rate only. All after hours service calls shall be handled by one mechanic only unless approved in advance by the COR. If regular timework must be carried over and the Contractor wishes to continue to work beyond the Medical Centers normal hours of operation, which are M-F 8:00 a.m.-4:30 p.m., authorization for afterhours work must be obtained from the COR before proceeding.

3. Medical Center shall not be responsible for incidental charges including, but not limited to, parking, tolls, mileage, phone, etc., on straight time or afterhours work.

4. Contractor shall notify the COR or designee by telephone or in person after completion of each regular time service call and notify the Medical Center Police on overtime calls.

M. Under no circumstances will any shutdown or breakdown last longer than five (5) working days (40 working hours), from initial notification to the Contractor, without prior approval of the COR.

N. All tests, inspections, or maintenance repairs that will remove an elevator from service shall be scheduled in advance with the COR.

O. The Contractor shall comply with the following procedures when an elevator is removed from service for any reason:

1. Notify Facilities Management Service, Electrical Shop Supervisor, either by phone (859-233-4511 x3379), or in person, before removing elevator from service. If work requires more than one day to repair, daily notification will be made. Notify Facilities Management Service when placing the elevator back in service. Contractors employees shall turn in Elevator Report Forms, which will furnish the information to the Electrical Foreman, Facilities Management Service.

P. The Contractor shall immediately notify the COR in writing of the existence or the development of any defects in, or repairs required to, the elevator, which the Contractor considers are not covered by the contract and shall furnish a written estimate, when requested, of the cost. Final determination of responsibility will be by mutual agreement between the COR and the Contractor.

Q. When planned work requires an elevator to be taken out of service, the Contractor is requested, when possible, to use the Federal holidays listed below.

New Year's Day
Washington’s Birthday
Martin Luther King’s Birthday
Memorial Day
Independence Day
Labor Day
Columbus Day
Veterans Day
Thanksgiving Day
Christmas Day

R. Inspection

1. Periodic inspections of the elevators required by the National American Standard Safety Code for Elevators and Escalators (Latest Edition) will be performed under separate contract in accordance with existing Lexington VAMC Policy. Upon completion of a routine inspection, the Contractor shall be furnished with an inspection report listing deficiencies for which he is responsible to repair within 30 calendar days. Items marked emergency should be corrected immediately but not later than five working days. Under no circumstances, shall the Contractor allow reported deficiencies to go uncorrected beyond the contract period.

2. The Contractor shall provide all labor and material to perform work in accordance with ASME A17.1, ASME A17.2, ASME A17.3, and ANSI/NFPA 70 standards for annual, 6 months, and five-year (traction only) tests. The Contractor shall perform tests at the date and time specified by the VAMC. Inspection of work shall be conducted by an independent inspector contracted by the VAMC. Maintenance contractor awarded this contract performs actual test.

S. Testing

1. The following services shall be performed at intervals specified in the American National Standard Safety Code for Elevators and Dumbwaiters. The maintenance Contractor shall furnish personnel to perform the 1 (one) year, and the 5 (five) year safety load test, (including weights), at no additional cost to the Medical Center. Scheduling of all tests will be handled through the COR. A Medical Centers Contractor, authorized by the Lexington VAMC, will witness all tests for the Medical Center, Lexington VAMC personnel, as required; will be available for the tests.

2. The Contractor shall make available the uninterrupted services of at least one employee to accompany the inspector during the course of any inspection.

3. The yearly car safeties, governor and oil buffer tests and inspections shall be complied with as per A17.1 and this specification, in the presence of the COR or his/her representative.

4. The five-(5) year safety and buffer tests as required by the American National Standard Safety Code for Elevators and Dumbwaiters, (A17.1 and A17.2) are to be performed by the Contractor.

5. Within six (6) months prior to the end of this contracts period of performance, a representative of the COR shall make a thorough inspection of all equipment covered under this contract. The Contractor shall correct all defects found within thirty (30) calendar days. The Contractor shall notify the COR in writing that the deficiencies have been corrected and that re-inspection can be made.

6. The inspectors used by the Medical Center on this contract may or may not work for the Medical Center. An outside company may be used to perform inspections as a representative of the Medical Center if so desired by the COR.

T. The following schedule for the five-year load test is required in the year 2021: See Schedule of Elevators. All elevators to be tested.

NOTE: THE WORD "ELEVATOR" IS THIS SOLICITATION SHALL INCLUDE ALL ELEVATORS, DUMBWAITERS, LIFTS, ETC., TO BE SERVICED UNDER THIS CONTRACT.

U. The following schedule for the annual test (with pressure testing) year load test is required: See Schedule of Elevators. All elevators to be tested.

V. Scheduled Maintenance Requirements

1. The Contractor shall be responsible for establishing an effective system for accomplishing scheduled and unscheduled maintenance, including a backlog listing of work to be accomplished. The scheduling system and backlog listing shall be available for inspection by the COR at any time.

2. Regular routine maintenance shall be performed at a frequency of not less than weekly for all equipment at both campuses.

3. PMIs are to be performed during administrative hours on the same day of each week. The contractor shall submit, at the beginning of the contract, to the Electrical Shop Foreman, the day of the week he/she intends on performing the required PMI. If the day falls on a holiday the contractor shall perform the required PMIs on the next business day following the holiday. The contractor shall notify the Electrical Shop Foreman if he/she intends on changing the PMI day or if he/she cannot perform the PMI ON schedule.

4. PMIs should ensure a safe and efficient level of operation, and all work relative to cleaning, lubricating, adjustment or part replacement of equipment that is necessary for the desired level of operation shall be performed by the Contractor. Each contract year, all items which rely on cleaning, lubrication, or routine part replacement shall receive such service at least once as indicated by service report. Any PMI required by the Equipment Manufacturer, and/or applicable laws, regulations, rules, ordinances, codes, etc, but not specifically identified by the Government, shall be performed by the Contractor at no additional cost to the Government. In addition, the contractor shall perform the following preventive maintenance and all necessary cleaning, lubricating, and adjusting pursuant to such maintenance at the frequencies identified. Frequencies shall be modified if deemed necessary by the COR or designee.

5. The Contractor is responsible for replacement of all light bulbs, including lights in elevator shafts on top and bottom of cars, HOISTWAY crawl spaces, elevator machine rooms, etc. This shall include all lights inside the elevator cabs.

6. The Contractor shall during regular PMI visits retrieve any objects such as key, wallets, glasses, etc. dropped in elevator pit by occupants of the building. Such objects shall be turned over to VA Police personnel.

7. The Contractor must maintain the efficiency, safety and speeds specified in the contract or as designated by the manufacturer of the elevators at all times; including acceleration, retardation, contact speed in feet per minute, with or without full load, floor to floor time and door opening and closing time.

W. Contractor shall provide qualified journeyman mechanic as needed to find and correct any deficiencies and complete all maintenance tasks. This is to be done above and beyond his/her repair time each week. Non-emergency services/repairs shall be completed at the time of inspections unless the Contractor requests, in writing, and obtains approval to perform repair work at a later date and time. The COR or designee shall be provided written notice in a timely manner. Contractor shall complete attached weekly/biweekly PM check chart to indicate whether specified key items were found to require maintenance and the nature of service performed. The check charts shall be completed and remain in the elevator machine room when work has been completed for the day.

X. The Contractor shall provide an additional qualified journeyman mechanic at the Medical Center from 8:00 a.m. to 4:30 p.m. if normal maintenance requires two journeymen to accomplish the maintenance schedule and assist in repairs, inspections and adjustments.

Y. Experience Requirements

1. Supervision: The Contractor shall arrange for satisfactory supervision of the contract work. The Contractor or his on-site supervisors shall be available at all times when the contract work is in progress to receive notices, reports, or request from the Contracting Officer or the COR.

2. Qualifications of Elevator Mechanics: All maintenance personnel directly engaged in the work to be accomplished under the contract shall possess, prior to their employment in a journeyman mechanic's capacity on this contract, at least 4 (four) years of recent (within the last 6 years) experience in the operations and maintenance of the kind of elevators to be maintained under this contract.

3. In addition to the above requirements, the Contractor shall have a minimum of 5 (five) years' successful experience in maintaining equipment identical or similar to the equipment covered by this contract. Each offeror shall submit, as part of his offer, references for the previous 5 (five) years' experience. The written references shall include, as a minimum, the name, address and telephone numbers of the specific companies and key personnel contacts.

Z. Condition of Equipment

1. Upon contract award, the contractor accepts "as is" all elevator equipment specified in the contract. Failure to inspect the elevators, prior to contract award, shall not relieve the contractor from performing services/repairs in accordance with the strict intent and meaning of the specifications at no additional cost to the VA. Quoters should inspect the premises prior to submitting their offers in order to be fully aware of the scope of services required.

AA. Uniforms

1. The Contractor shall require all employees, including supervisors, to wear distinctive uniform clothing for ready identification, and assure that every employee is in uniform no later than the time specified by the COR, or otherwise no later than 10 working days from the date an employee first enters on duty. The uniform shall have the Contractor's name, easily identifiable, affixed thereon in a permanent manner such as a badge or monograms.

AB. Safety

1. The Contractor shall adhere to all OSHA, EPA, NFPA Life Safety Codes, and all other regulatory requirements.

2. In performance of this contract, the Contractor shall follow VAMC safety policy and standard for safe work practices, and take such safety precautions as the Safety Officer or designee may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contractor shall comply with VAMC smoking policy, which designates all interior space as non-smoking areas.

3. Patient, employee, visitors, and contractor personnel safety shall be maintained at all times. The contractor is responsible for the occupation safety and health of his/her employees. The Contractor shall comply with all applicable OSHA safety and health standards. The Contractor shall replace all safety guards, equipment, devices, etc. removed to service or repair the elevator immediately after completion of work or when leaving the job unattended.

4. The Contractor shall submit to the COR, prior to the start of the contract, the Safety Data Sheets (SDS) for all potentially hazardous materials (lubricants, cleaners, working fluids, etc.) to be used in the facility in performance of the contract, and shall not use, in the facility, such materials which have not been so cleared in advance with the VAMC. SDS for new chemicals shall be furnished concurrently with arrival of the chemical on site. The Contractor shall maintain a copy of all SDS at the chemical storage site in a location accessible to VAMC personnel to assure compliance with all laws and requirements regarding the "Right to Know" law.

5. The Contractor is responsible to identify, provide and maintain all personal protective equipment required to perform the duties outlined in the contract. In addition, the contractor is responsible for identifying and providing all applicable safety programs (i.e. lockout/tag out, confined space entry, universal precautions, etc.) required to perform the work. Training on required safety programs and the proper use of PPEs shall be provided, and documentation maintained by the contractor.

6. The Contractor shall obtain a Hot Work Permit from the Safety Office whenever soldering, welding, using a cutting torch, or other open flame, spark, or heat producing equipment. The contractor is required to follow ALL requirements outlined for the issuance of the Hot Work Permit.

7. The Contractor shall be notified of any non-compliance with the above-mentioned provisions. The contractor shall, after receipt of such notice, immediately correct the condition and notify the COR in writing that the condition has been corrected. If in the opinion of the Safety Officer or designee the condition is life threatening he/she shall instruct the contractor to stop work until the condition has been corrected. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue and order halting of all or any part of the work, The Contractor bears all costs of stop work time and correcting safety hazards.

8. The contractor shall provide the COR within ten (10) calendar days after receipt of this contract a detailed listing of the following information:

a) Safety program/procedures are required to be followed by the contractor's personnel in the performance of their duties and when such procedures are required.

b) Listing of personal protective equipment(s) required to be utilized by the contractor's personnel in the performance of their duties.

c) Safety Data Sheets (SDS's) for any chemical(s) utilized by the contractor in the performance of this contract.

9. Contractor is responsible for the supervision of all their employees while on government property. It is the Contractor's responsibility to assure compliance with the scope of work and requirements referenced in this contract. Provisions provided in the scope of work are not intended to relieve the Contractor of this responsibility.

AC. Injury or Accident

1. Contractor shall submit a written report to the COR within five calendar (5) days of any incident of a major malfunction, accident or injury involving an elevator. The report shall state the cause, what and when repairs and tests were or are to be made to correct the cause of the incident.

AD. Quality Control Program

1. The Contractor shall establish a complete quality control program to assure the requirements of the contract are provided as specified, within five (5) calendar days prior to the starting date of the contract, the Contractor shall submit a copy of his program to the COR, for approval. The program shall include, but not be limited to, the following:

2. An inspection system covering all the services described in the contract. A checklist used in inspecting contract performance during regularly scheduled or unscheduled inspections. The name(s) of the individual(s) who shall perform the inspection.

3. The checklist shall include every area of the Contractor's operation as well as every task required to be performed.

4. A system for identifying and correcting deficiencies in the quality of services before the level of performance becomes unacceptable and/or the Medical Center inspectors point out the deficiencies.

5. A file of all inspections conducted by the Contractor and the corrective action taken. This documentation shall be made available to the Medical Center upon request, at any time during the term of the contract.

AE. Emergency Telephone Numbers

1. The Contractor shall provide the COR with pertinent emergency telephone numbers, in order to summon assistance in case an emergency develops. At least one of the emergency telephone numbers shall be manned twenty-four (24) hours per day. This information shall be provided in writing to the COR, prior to the contract start date.

AF. Information Relating to Conduct of Contractor's Employees

1. The Contractor shall prohibit his employees form disturbing papers on desks, opening desk drawers or cabinets, or using telephones or office equipment provided for official Medical Center use.

2. Contractor shall require his employees to comply with the instructions pertaining to conduct and other regulations called to the Contractor's attention by the CO/COR, Federal Protective Officers, Inspectors, etc.

3. Contractor shall use firefighters service test log for monthly and yearly log, starting October to September.

3. Contractor shall report to the COR where there is a passenger trap incident, or safety incident. Elevator failure of more than 8 (eight) hours of downtime. Stating date when parts are available and expected time of repair, tested and back useful service.

AG. General Information

1. The Contractor shall immediately notify the COR (in writing) of the existence of the development of any defects in, or repairs required to the elevators which the contractor considers he is not responsible for under the terms of the contract, and shall furnish the COR a written estimate of the cost to make necessary repairs. The contracting officer reserves the right to make final determination of the responsibility. The Contracting Officer also reserves the right to solicit the services of other contractors to make said repairs.

2. The Government reserves the right to perform emergency repairs to any elevator which is disabled if, in the Government's opinion, it jeopardizes patient or employee safety.

3. The Contractor shall ensure that the elevator pits(s) and elevator machine room(s) are kept clean and free from dirt and debris. Contractor shall clean and vacuum all HOISTWAY(s), pit(s) and machine rooms once a month to remove dust and debris accumulation.

4. The Contractor shall require his employees to comply with all VA rules and regulations pertaining to the conduct of his employees while on station. Particular attention is drawn to the fact that the VAMC Lexington is a NO SMOKING Facility. Smoking is not permitted in any building (including Penthouses and elevator pits).

5. Contractor shall have use of station telephones to make business calls related to Medical Center's equipment. Misuse of this privilege shall necessitate the need to require the contractor to use public telephones.

2. EMERGENCY SERVICE OR REPAIRS NOT COVERED BY THE CONTRACT

**DEFINITION OF LABOR RATE MEANS WHAT THE HOURLY RATE IS TO MAKE REPAIRS THAT ARE NOT COVER UNDER THE CONTRACT, NO MATTER THE TIME OR DAY.** PARTS AND MATERIALS NOT COVERED UNDER THIS CONTRACT SHALL BE PROVIDED AT THE CONTRACTOR'S ACTUAL INVOICED COST.

*NOTE: BASE YEAR AND OPTION YEARS LABOR RATES FOR ELEVATOR REPAIR AND SERVICES ARE NOT PURCHASED BY THIS CONTRACT. VAMC RESERVES THE RIGHT TO PURCHASE REPAIR SERVICES FROM SOURCES OTHER THAN THE AWARDEE WHEN DETERMINED TO BE IN THE BEST INTEREST OF THE GOVERNMENT. *

3. SPECIAL CONDITIONS

A. QUALIFICATION OF QUOTERS

1. Upon request of the Government, quoter shall be able to show evidence of his reliability, ability and experience by furnishing; (1) A list of personnel who shall perform under the contract showing the length and type of experience of such personnel and (2) the names and addresses of other concerns and/or Government Agencies for which prior comparable services were rendered by the bidder. Generally, the bidder shall have had approximately 5 years successful experience in fully maintaining elevators.

2. Ability to meet the foregoing experience requirements and the adequacy of the information submitted will be considered by the Contracting Officer in determining the responsibility of the bidder.

B. INSPECTION OF PREMISES

1. The Contractor accepts "as is" existing condition of equipment and government furnished parts covered under this full-service agreement at time of contract award.

2. Equipment deficiencies not meeting manufacturer's operational standards shall be corrected by the Contractor at no additional cost to the Government.

C. QUALIFICATIONS OF MECHANICS

1. All work under this contract shall be performed by an Elevator Mechanic. Elevator Mechanic Helpers or Probationary Helpers shall be allowed to assist in maintaining specified equipment only in the presence of an Elevator mechanic. Helpers shall only be allowed to work by themselves if performing lubrication or cleaning service.

SCHEDULE OF ELEVATORS

Leestown Road

Location
Type
Manufacture
Installed
1-1
Traction
Imperial -Motor; Motion – Controls; GAL – Doors.
2011
1-2
Traction
Imperial -Motor; Motion – Controls; GAL – Doors.
2011
2-1
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2012
2-2
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2012
3-1
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2011
3-2
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2013
3-3
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2012
16-1
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2013
16-2
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2013
17-1
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2012
17-2
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2012
25-1
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2011
25-2
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2011
27-1
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2012
27-2
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2012
28-1
Traction
Dover/Out of service
1976
28-2
Hydro
Esco/Out of service
1976
29-1
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2013
29-2
Hydro
Canton – Hydraulics; Motion – Controls; GAL – Doors.
2013

F. POINTS OF CONTACT

1. VAMC POC’s are as follows:

Name
Title
Telephone
David Milner
Contract Specialist
(615) 225-6543
Michael Neville
Electrical Supervisor
(859) 233-4511 x 3379
Rod Ipakchian
Asst Chief, Eng Svc
9859) 233-4511 x 3350

B.3 PRICE/COST SCHEDULE

ITEM INFORMATION

ITEM NUMBER
DESCRIPTION OF SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
12.00
MO
__________________
__________________

Full service maintenance of 28 elevators at VA Medical Center Leestown Road and Cooper Drive Divisions (Including Clinical Addition), Lexington Kentucky as show on revised schedule of Elevators per the Statement of Work Contract Period: Base POP Begin: 10-01-2018 POP End: 09-30-2019

28.00
EA
__________________
__________________

ASME A17 Semi Annual inspections

28.00
EA
__________________
__________________

ASME A17 Annual inspections

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Mechanic

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Assistant/Helper

12.00
MO
__________________
__________________

Full service maintenance of 28 elevators at VA Medical Center Leestown Road and Cooper Drive Divisions (Including Clinical Addition), Lexington Kentucky as show on revised schedule of Elevators per the Statement of Work.

Contract Period: Option 1 POP Begin: 10-01-2019 POP End: 09-30-2020

28.00
EA
__________________
__________________

ASME A17 Semi Annual inspections

28.00
EA
__________________
__________________

ASME A17 Annual inspections

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Mechanic

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Assistant/Helper

12.00
MO
__________________
__________________

Full service maintenance of 28 elevators at VA Medical Center Leestown Road and Cooper Drive Divisions (Including Clinical Addition), Lexington Kentucky as show on revised schedule of Elevators per the Statement of Work.

Contract Period: Option 2 POP Begin: 10-01-2020 POP End: 09-30-2021

28.00
EA
__________________
__________________

ASME A17 Semi Annual inspections

28.00
EA
__________________
__________________

ASME A17 Annual inspections

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Mechanic

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Assistant/Helper

28.00
EA
__________________
__________________

ASME A17 Five Year load Test

12.00
MO
__________________
__________________

Full service maintenance of 28 elevators at VA Medical Center Leestown Road and Cooper Drive Divisions (Including Clinical Addition), Lexington Kentucky as show on revised schedule of Elevators per the Statement of Work.

Contract Period: Option 3 POP Begin: 10-01-2021 POP End: 09-30-2022

28.00
EA
__________________
__________________

ASME A17 Semi Annual inspections

28.00
EA
__________________
__________________

ASME A17 Annual inspections

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Mechanic

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Assistant/Helper

12.00
MO
__________________
__________________

Full service maintenance of 28 elevators at VA Medical Center Leestown Road and Cooper Drive Divisions (Including Clinical Addition), Lexington Kentucky as show on revised schedule of Elevators per the Statement of Work.

Contract Period: Option 4 POP Begin: 10-01-2022 POP End: 09-30-2023

28.00
EA
__________________
__________________

ASME A17 Semi Annual inspections

28.00
EA
__________________
__________________

ASME A17 Annual inspections

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Mechanic

1.00
HR
__________________
__________________

Labor Hour Rate, Elevator Assistant/Helper

GRAND TOTAL
__________________

Page 1 of Page 1 of

SECTION C - CONTRACT CLAUSES

ADDENDUM to FAR 52.212-4 CONTRACT TERMS AND CONDITIONS—COMMERCIAL ITEMS Clauses that are incorporated by reference (by Citation Number, Title, and Date), have the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available.

The following clauses are incorporated into 52.212-4 as an addendum to this contract:

C.1 52.252-2 CLAUSES INCORPORATED BY REFERENCE (FEB 1998)

This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es):

http://www.acquisition.gov/far/index.html http://www.va.gov/oal/library/vaar/

(End of Clause)

FAR Number
Title
Date
52.203-17
CONTRACTOR EMPLOYEE WHISTLEBLOWER RIGHTS AND REQUIREMENT TO INFORM EMPLOYEES OF WHISTLEBLOWER RIGHTS
APR 2014
52.204-4
PRINTED OR COPIED DOUBLE-SIDED ON RECYCLED PAPER
MAY 2011
52.204-9
PERSONAL IDENTITY VERIFICATION OF CONTRACTOR PERSONNEL
JAN 2011
52.228-5
INSURANCE—WORK ON A GOVERNMENT INSTALLATION
JAN 1997
52.232-18
AVAILABILITY OF FUNDS
APR 1984
52.232-40
PROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS
DEC 2013

C.2 52.216-18 ORDERING (OCT 1995)

(a) Any supplies and…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.