544-16-100
6439 GARNERS FERRY ROAD COLUMBIA, SC
100% BID SET
SAP12/21/2017
WILLIAM JENNINGS BRYAN DORN
VA MEDICAL CENTER
DATE-1DESCRIPTION-1
(706) 774-1020
ING CONSULTING INC
1201 Broad Street, Suite 1-A Augusta, GA 30901
(706) 724-3551
ELECTRICAL DESIGN CONSULTANTS
550 11th Street Augusta, GA 30901
(706) 556-0197
VETERANS 1ST ARCHITECTURE
110-A North Louisville Street Harlem, GA 30814
DATE-2DESCRIPTION-2
DATE-3DESCRIPTION-3
DATE-4DESCRIPTION-4
DATE-5DESCRIPTION-5
DATE-6DESCRIPTION-6
DATE-7DESCRIPTION-7
DATE-8DESCRIPTION-8
DATE-9DESCRIPTION-9
RENOVATE OR SUITE
PLUMBING LEGEND, ABBREVIATIONS
& NOTES
PL000
12/21/2017
6439 GARNERS FERRY ROAD COLUMBIA, SC
100% BID SET
SAP12/21/2017
WILLIAM JENNINGS BRYAN DORN
VA MEDICAL CENTER
DATE-1DESCRIPTION-1
(706) 774-1020
ING CONSULTING INC
1201 Broad Street, Suite 1-A Augusta, GA 30901
(706) 724-3551
ELECTRICAL DESIGN CONSULTANTS
550 11th Street Augusta, GA 30901
(706) 556-0197
VETERANS 1ST ARCHITECTURE
110-A North Louisville Street Harlem, GA 30814
DATE-2DESCRIPTION-2
DATE-3DESCRIPTION-3
DATE-4DESCRIPTION-4
DATE-5DESCRIPTION-5
DATE-6DESCRIPTION-6
DATE-7DESCRIPTION-7
DATE-8DESCRIPTION-8
DATE-9DESCRIPTION-9
RENOVATE OR SUITE
PLUMBING SCHEDULES
PL001
PLUMBING NARRATIVE MATRIX
SYSTEMS SHEET ABBREV. PIPING / FITTING TYPE JOINING TYPE VALVE INSULATION
TYPE
BELOW SLAB
2"-4" DIA
SANITARY/WASTE
SAN SERVICE WEIGHT CAST IRON
ASTM A 888
NO-HUB COUPLING - HEAVY DUTY
ASTM C 1540
- 1" THICKNESS
ASJ-SSL FIBERGLASS
FLOOR DRAIN BODIES, TRAPS &
PIPING FROM FLOOR DRAINS TO 5'
DOWNSTREAM
ABOVE SLAB
1 1/4"-1 1/2" DIA
SANITARY/WASTE
SAN COPPER DWV
ASTM B 306
SOLDERED
ASTM B 813
SANITARY/WASTE
VENT
V SERVICE WEIGHT CAST IRON
ASTM A 888
NO-HUB COUPLING - HEAVY DUTY
ASTM C 1540
DOMESTIC COLD DCW COPPER TYPE L
HARD DRAWN TUBE
WROUGHT - COPPER PRESSURE FITTINGS
ASTM B 88
SOLDERED
ASTM B 16.18
LEAD-FREE
1"-3" BALL VALVE
FULL PORT TWO PIECE W/ HANDLE EXTENSION
MSS SP-110
PRESSURE RATING 150PSIG
ASJ-SSL FIBERGLASS
1" THICKNESS: 1/2" - 3"
DOMESTIC HOT DHWS COPPER TYPE L
HARD DRAWN TUBE
WROUGHT - COPPER PRESSURE FITTINGS
ASTM B 88
SOLDERED
ASTM B 16.18
LEAD-FREE
1"-3" BALL VALVE
FULL PORT TWO PIECE W/ HANDLE EXTENSION
MSS SP-110
PRESSURE RATING 150PSIG
ASJ-SSL FIBERGLASS
1" THICKNESS: 1/2" - 1 1/4"
2" THICKNESS: 1 1/2" - 3"
HOT WATER RETURN DHWR COPPER TYPE L
HARD DRAWN TUBE
WROUGHT - COPPER PRESSURE FITTINGS
ASTM B 88
SOLDERED
ASTM B 16.18
LEAD-FREE
1"-3" BALL VALVE
FULL PORT TWO PIECE W/ HANDLE EXTENSION
MSS SP-110
PRESSURE RATING 150PSIG
ASJ-SSL FIBERGLASS
1" THICKNESS: 1/2" - 1 1/4"
2" THICKNESS: 1 1/2" - 3"
ROOF DRAIN RD SERVICE WEIGHT CAST IRON
ASTM A 888
NO-HUB COUPLING - XTRA HEAVY DUTY
ASTM C 1540
JOINT RESTRAINTS
- ASJ-SSL FIBERGLASS
ROOF DRAIN BODIES AND ALL
HORIZONTAL & VERTICAL PIPING
MEDICAL GAS O2, MA, CO2, N2, N2O COPPER TYPE L
SEAMLESS DRAWN TEMPERED TUBING PURGE CAPPED
LABELED FOR OXY/MED
WROUGHT-COPPER FITTINGS
CLEANED BAGGED
BRAZED JOINT
AWS A5.8/A5.8M, BCUP SERIES, COPPER-PHOSPHORUS
ALLOYS.
1"-3" BALL VALVE
FULL PORT THREE PIECE LOCKABLE HANDLE
MSS SP-110
PRESSURE RATING 300PSIG
MEDICAL VACUUM VAC COPPER TYPE L
SEAMLESS DRAWN TEMPERED TUBING PURGE CAPPED
LABELED FOR OXY/MED
WROUGHT-COPPER FITTINGS
CLEANED BAGGED
BRAZED JOINT
AWS A5.8/A5.8M, BCUP SERIES, COPPER-PHOSPHORUS
ALLOYS.
1"-3" BALL VALVE
FULL PORT THREE PIECE LOCKABLE HANDLE
MSS SP-110
PRESSURE RATING 300PSIG
STEAM LPS STEEL PIPING SCHED. 80
TYPE S GRADE B THREAED JOINTS
ASTM A 53 / A 53M BLACK STEEL
ASME B31.9
MALLEABLE IRON THREADED FITTINGS & UNIONS
ASME B16.3 CLASS 150
BALL VALVES: 600PSI WOG 150PSIG, TWO PIECE, FULL
PORT, STAINLESS-STEEL TRIM,
(FILLED OR REINFORCED) RPTFE SEAT
BRONZE GATE VALVES: CLASS 150 NRS
STEAM SERVICE RATED
BRONZE GLOBE VALVES: CLASS 150 NONMETALLIC DISC
STEAM SERVICE RATED
ASJ-SSL FIBERGLASS
2" THICKNESS REQUIRED FOR
STEAM PIPING, CONDENSATE
RETURN, CONDENSATE DRAIN,
CONDENSATE PUMP RECEIVER VENT
& OVERFLOW PIPING. JACKETED
WITH ALUMINUM JACKET AND
BANDS.
Demolition The existing plumbing waste, vent, domestic cold, hot, hot water return, med gas, & med vacuum, steam piping and associated fixtures will be removed and piping temporarily capped to allow for new work.
Existing vent terminal through roof will remain in existing locations until new work piping is in place for cut over.
New Work Sanitary waste piping will be show in the 3rd floor ceiling along with Phasing as required by Owner/Occupants. Existing vent piping will be re-routed and extended into newly created 4th floor wall cavities to connect in existing vent terminal through roof. Piping types will be per the above Plumbing Narrative Matrix.
New Roof drain piping will extend the existing Roof Drain piping system above the 4th floor ceiling into newly created 4th floor wall cavities to connect to existing piping in the 3rd floor ceiling cavity. Piping types will be per the above Plumbing Narrative Matrix.
Domestic cold, hot and hot water return piping will be shown to extend from existing piping above the 4th floor ceiling to new fixtures per the VA Standard Design Plates. Piping types will be per the above Plumbing Narrative Matrix.
Med Gas & Med Vacuum will be extended from existing piping above the 4th floor ceiling to new recessed zone valve boxes. New Med Gas & Med Vacuum will extend from the zone valve box to outlets located in each room per the VA Standard Design Plates. Piping types will be per the above Plumbing Narrative Matrix.
LPS Steam piping will extend existing steam piping in the mechanical room to connect to new Air Handler Unit internal steam humidifier. Piping types will be per the above Plumbing Narrative Matrix.
MEDICAL GAS ALARM PANEL SCHEDULE
LOCATION TYPE OF
PANEL
GAGES SERVICE INDICATOR LIGHTS
SURGERY CONTROL
ROOM
AREA ALARM
PANEL
YES OXYGEN LINE PRESSURE ABNORMAL
NITROUS OXIDE LINE PRESSURE ABNORMAL
NITROGEN LINE PRESSURE ABNORMAL
MEDICAL AIR LINE PRESSURE ABNORMAL
MEDICAL VACUUM LINE PRESSURE LOW
TEST BUTTON
RECOVERY ROOMS AREA
(ZONE)
ALARM
PANEL
YES OXYGEN LINE PRESSURE ABNORMAL
NITROUS OXIDE LINE PRESSURE ABNORMAL
NITROGEN LINE PRESSURE ABNORMAL
MEDICAL AIR LINE PRESSURE ABNORMAL
MEDICAL VACUUM LINE PRESSURE LOW
TEST BUTTON
PLUMBING FIXTURE UNIT CALCULATION
MARK DESCRIPTION
Quanity
Drainage F.U. Per Fixture
Potable F.U. Per Fixture
HOT F.U.
Per Fixture
Drainage Total
Potable Total HOT Total
P-101 TOILET- WALL
HUNG
4 4 10 16 40
P-401.0,1,2 LAVATORY 12 1 1.5 1.5 12 18 18
P-510 SINGLE BOWL
SINK COUNTER
MOUNTED
7 2 1.5 1.5 14 10.5 10.5
P-512 SINGLE BOWL
SINK COUNTER
MOUNTED WITH
EYEWASH
1 2 1.5 1.5 2 1.5 1.5
P-519 SCRUB SINK
DOUBLE
4 3 1.5 1.5 12 6 6
P-521 MOP BASIN 1 3 3 3 3 3 3
P-701 SHOWER 2 3 3 6 6
P-708 WALL MOUNTED
EYEWASH
1 0 0
IB-1 ICE VALVE BOX 2 1 2 0
ZVB-1 MED GAS 6-VALVE
ZONE BOX
4 0 0
ZVB-2 MED GAS 3-VALVE
ZONE BOX
1 0 0
FD FLOOR DRAIN 2 2 4 0 0
FCO FLOOR CLEANOUT 0 0
63 87 45
87 FU = 65 GPM 45 FU = 27 GPM
Total Demand
POTABLE = 65 GPM - 2-1/2"CW
SERVICE
HOT = 27 GPM - 1-1/2"HW
SERVICE
PLUMBING FIXTURE SCHEDULE
MARK DESCRIPTION BASIS OF DESIGN CONNECTIONS NOTES
MFR MODEL CW HW WASTE VENT
P-101 TOILET- WALL
HUNG
KOHLER
SLOAN
BEMIS
J.R. SMITH
K-4330 111-1.28
2155_SSCT
0419(L)(R)Y
1-1/4" - 4" 2" ADDITIONAL 2"NO HUB INLET-CONTRACTOR TO FIELD VERIFY LEFT AND RIGHT HAND
WITH INSTALLATION REQUIREMENTS
P-401.0 LAVATORY KOHLER
DELTA
TRUEBRO
K-1723
27C4875-TI
103EZ
1/2" 1/2" 1-1/4 " / 2" 2" C.P. CAST BRASS 17GA OFFSET GRID DRAIN, TRAP WITH CLEANOUT, RIGID C.P. BRASS
TUBE SUPPLIES, C.P. ANGLE STOPS
P-401.1 LAVATORY KOHLER
DELTA
J.R. SMITH
TRUEBRO
K-1723
27C4875-TI
103EZ
1/2" 1/2" 1-1/4 " / 2" 2" C.P. CAST BRASS 17GA OFFSET GRID DRAIN, TRAP WITH CLEANOUT, RIGID C.P. BRASS
TUBE SUPPLIES, C.P. ANGLE STOPS
P-401.2 LAVATORY KOHLER
DELTA
J.R. SMITH
TRUEBRO
K-1723
27C4875-TI
0710DZ
103EZ
1/2" 1/2" 1-1/4 " / 2" 2" C.P. CAST BRASS 17GA OFFSET GRID DRAIN, TRAP WITH CLEANOUT, RIGID C.P. BRASS
TUBE SUPPLIES, C.P. ANGLE STOPS
P-510 SINGLE BOWL SINK
COUNTER
MOUNTED
JUST
DELTA
SL-1815-A-GR
27C4975-TI
1/2" 1/2" 1-1/2" / 2" 2" MCGUIRE C.P. CAST BRASS 17GA OFFSET GRID DRAIN, TRAP WITH CLEANOUT, RIGID
C.P. BRASS TUBE SUPPLIES, C.P. ANGLE STOPS
P-512 SINGLE BOWL SINK
COUNTER
MOUNTED WITH
EYEWASH
JUST
DELTA
GUARDIAN
GUARDIAN
SL-1815-A-GR
27C4875-TI
G1893
G3602LF
1/2" 1/2" 1-1/2" / 2" 2" MCGUIRE C.P. CAST BRASS 17GA OFFSET GRID DRAIN, TRAP WITH CLEANOUT, RIGID
C.P. BRASS TUBE SUPPLIES, C.P. ANGLE STOPS & COUNTER MOUNT EYEWASH
LOCATED ALONG LEFT EDGE OF SINK PER MANUFACTUERS I.O.M. INSTALL SURFACE
MOUNT MIXING VALVE ABOVE CEILING.
P-519 SCRUB SINK DOUBLE JUST
DELTA
J-770-2
1501T3478TR-R7
1/2" 1/2" 2" 2" SURGEONS SCRUB SINK DOUBLE
P-521 MOP BASIN FLORESTONE
DELTA
28T9
1/2" 1/2" 3" 2" MOP BASIN, DELTA #28T9 FAUCET
P-701 SHOWER SYMMONS 3505-H321-V-CYL-B 1/2" 1/2" - - SYMMONS DIA #3501-CYL-B-LP-CHKS
P-708 WALL MOUNTED
EYEWASH
GAURDIAN
GUARDIAN
G1891
G3600LF
1/2" 1/2" 1-1/4" 2" WALL MOUNTED EYEWASH STATION
DB DRAIN BOX CHARLOTTE 2"x4" CAST IRON NO-HUB
INCREASER
- - 2" 2" 2"CAST IRON NO-HUB DRAIN PIPING PENETRATION W/ 2"TO 4" INCREASER EXPOSED
3' A.F.F. BEHIND STAINLESS STEEL WALL ACCESS DOOR TO EXCEPT DRAIN PIPING
FROM OVERHEAD WITH AIR GAP FITTING. SEE DETAIL 3 ON SHEET PL003.
IB-1 ICE VALVE BOX OATLEY 38570 1/2" - - - ICE MAKER VALVE BOX FOR RECESSED WALL MOUNTING T-HANDLE 1/4" TURN BALL
VALVE.
ZVB-1 MED GAS 6-VALVE
ZONE BOX
MEDAES ZVB6 - - - - 6-VALVE BOX RECESSED IN WALL. COORDINATE VALVE SIZES WITH PROJECT
REQUIREMENTS AND INSTALL PER NFPA 99, 2012 EDITION WITH SC AMENDMENTS.
ZVB-2 MED GAS 3-VALVE
ZONE BOX
MEDAES ZVB3 - - - - 3-VALVE BOX RECESSED IN WALL. COORDINATE VALVE SIZES WITH PROJECT
REQUIREMENTS AND INSTALL PER NFPA 99, 2012 EDITION WITH SC AMENDMENTS.
FD FLOOR DRAIN J.R. SMITH 2005Y-B-NB - - 3" 2" J.R.SMITH 2005Y-B-NB STRAINER W/ TRAP PRIMER
FCO FLOOR CLEANOUT J.R. SMITH 4052L-NB - - S.I.P. - J.R. SMITH 4052L-NB
ABBV. DESCRIPTION ABBV. DESCRIPTION ABBV. DESCRIPTION
F.V. FLUSH VALVE R.M. RECESSED WALL MOUNTED D.B. DRAIN BOX
T.T. TANK TYPE W.F. WALL FLANGE STYLE
W.M. WALL MOUNTED S.I.P. PROVIDE / INSTALL SIZE INDICATED ON PLANS
HAND HAND WAND/SLIDE A.C.M. ABOVE CEILING MOUNT
C.M. COUNTER MOUNTED C.P. CHROME POLISHED
SP-LVL SPLIT LEVEL ARRANGEMENT G.M. GROUND MOUNTED
F.M. FLOOR MOUNTED
PLUMBING FIXTURE AND ROUGH-IN NOTES:
1. MANUFACTURER'S AND MODEL NUMBERS SHOWN ABOVE ARE MINIMUM EQUIPMENT / FIXTURE REQUIREMENTS AND ARE THE BASIS OF DESIGN. CONTRACTOR SHALL REFERENCE SPECIFICATIONS FOR ADDITIONAL ACCEPTABLE MANUFACTURERS. PRODUCTS FROM OTHER LISTED MANUFACTURERS MUST MEET THE BASIS OF DESIGN. ALL EQUIPMENT AND INSTALL SHALL MEET PROJECT ISSUE DATE STATE'S ADOPTED IBC, IMC, IPC, NEC, IFGC, IECC AND
ASHRAE 90.1.
2. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE MOUNTING HEIGHTS. [ALL ACCESSIBLE FIXTURES SHALL COMPLY W/ AMERICAN DISABILITY ACT LATEST REVISION AS PUBLISHED BY DEPARTMENT OF JUSTICE ACCESS BOARD AND AMMENDED BY THE STATE OF GEORGIA. NON ACCESSIBLE FIXTURES SHALL COMPLY WITH ARCHITECTURAL DRAWINGS AND MANUFACTURER RECOMMENDED INSTALLATION HEIGHTS.
3. ALL FIXTURES SHALL BE WHITE IN COLOR. FLUSHING LEVERS SHALL BE MOUNTED TO WIDE SIDE OF TOILET.
4. ALL WATER HAMMER ARRESTERS VALVES TO BE INSTALLED IN AN ACCESSIBLE LOCATION, UNLESS SEALED PISTON TYPE APPROVED FOR CONCEALED CONSTRUCTUTION ARE INSTALLED.
6439 GARNERS FERRY ROAD COLUMBIA, SC
100% BID SET
SAP12/21/2017
WILLIAM JENNINGS BRYAN DORN
VA MEDICAL CENTER
DATE-1DESCRIPTION-1
(706) 774-1020
ING CONSULTING INC
1201 Broad Street, Suite 1-A Augusta, GA 30901
(706) 724-3551
ELECTRICAL DESIGN CONSULTANTS
550 11th Street Augusta, GA 30901
(706) 556-0197
VETERANS 1ST ARCHITECTURE
110-A North Louisville Street Harlem, GA 30814
DATE-2DESCRIPTION-2
DATE-3DESCRIPTION-3
DATE-4DESCRIPTION-4
DATE-5DESCRIPTION-5
DATE-6DESCRIPTION-6
DATE-7DESCRIPTION-7
DATE-8DESCRIPTION-8
DATE-9DESCRIPTION-9
RENOVATE OR SUITE
MED GAS SCHEDULE
PL002
PLUMBING SERVICES ROOM DATA SCHEDULE
ROOM NUMBER ROOM NAME MED GAS NEW EXISTING
ROOM NUMBER
EXISTING
ROOM NAME
EXISTING MED GAS
O₂ MED. COMPRESSED AIR VAC NITROGEN WAGD NITROUS OXIDE CARBON DIOXIDE O₂ MED. COMPRESSED AIR VAC
QTY. SCFM ROUGH
IN
QTY. SCFM ROUGH
IN
QTY. SCFM ROUGH
IN
QTY. SCFM ROUGH
IN
QTY. SCFM ROUGH
IN
QTY. SCFM ROUGH
IN
QTY. SCFM ROUGH
IN
QTY. SCFM ROUGH
IN
QTY. SCFM ROUGH
IN
QTY. SCFM ROUGH
IN
4A142 CORR. 4A140 SOCIAL WORKER
4A143 CLEAN UTILITY 4A141 STUDY CUBICLES
4A144 GAS CYL. STOR. 4A142 PULMO RES
4A145 WORK ROOM 4A143 CARDIO RES
4A146 SOILED UTILITY 4A144 SOCIAL WORKER
4A147 CORR. 4A145 MED SERVE ADMIN
4A148 PACU 1 1/2" 1 1/2" 1 3/4" 4A146 RES
4A149 PACU 1 1/2" 1 1/2" 1 3/4" 4A147 RES
4A150 PACU 1 1/2" 1 1/2" 1 3/4" 4A148 RES
4A151 PACU 1 1/2" 1 1/2" 1 3/4" 4A149 ASSIST CHIEF
4A152 PACU 1 1/2" 1 1/2" 1 3/4" 4A150 CHIEF
4A153 ANTE ROOM 4A151 SECY & WAIT
4A154 ISO. PACU 1 1/2" 1 1/2" 1 3/4" 4A153 CLERK
4A155 CORR. 4A154 MED SERV RES
4A156 MED. 4A155 RES
4A157 ANESTH. ROOM 4A156 RES
4A158 LOCKERS 4A158 MULTI BED ICU 16 1/2" 8 1/2" 24 3/4"
4A159 TLT 4A159 INTERVIEW AND CONS.
4A160 LOCKERS 4A160 CLEAN UTILITY
4A161 TLT 4A161 SOILED UTILITY
4A162 CORR. 4A162 H.A.C.
4A163 OR EQUIP. 4A163 TOILET
4A164 PRE-OP 1 1/2" 1 1/2" 1 3/4" 4A164 ISO-2 2 1/2" 1 1/2" 3 3/4"
4A165 PRE-OP 1 1/2" 1 1/2" 1 3/4" 4A165(6) EQUIPMENT STORAGE
4A166 PRE-OP 1 1/2" 1 1/2" 1 3/4" 4A166 WAITING
4A167 PRE-OP 1 1/2" 1 1/2" 1 3/4" 4A167 TOILET
4A168 PRE-OP 1 1/2" 1 1/2" 1 3/4" 4A168 ISO-1 2 1/2" 1 1/2" 3 3/4"
4A169 PRE-OP 1 1/2" 1 1/2" 1 3/4" 4A169 OBS-10 1 1/2" 1 1/2" 1 3/4"
4A170 PAT. TLT. 4A170 TOILET
4A171 ELEC 4A171 OBS-9 1 1/2" 1 1/2" 1 3/4"
4A172 CORR. 4A172 TOILET
4A173 STORAGE 4A173 OBS-8 1 1/2" 1 1/2" 1 3/4"
4A174 PAT. TLT. 4A174 TOILET
4A175 CORR. 4A175 H.A.C.
4A176 VEST 4A176 OBS-7 1 1/2" 1 1/2" 1 3/4"
4A177 HYBRID OR CONTROL 4A177 TOILET
4A178 HYBRID OR 2 1/2" 1 1/2" 8 3/4" 2 1/2" 1 3/4" 1 1/2" 2 1/2" 4A178 STRETCH. SHOWER
4A179 VEST 4A179 OBS-6 1 1/2" 1 1/2" 1 3/4"
4A180 SAT. LAB. 4A180 TOILET
4A181 OR STORAGE 4A181 NOUR. KIT.
4A182 PUMP ROOM 4A182 OBS-5 1 1/2" 1 1/2" 1 3/4"
4A183 VEST 4A183 TOILET
4A184 RAD STORAGE 4A184 NURSE STATION
4A185 CORR. 4A185 TOILET
4A186 CARDIO THORACIC OR 2 1/2" 1 1/2" 8 3/4" 2 1/2" 1 3/4" 1 1/2" 2 1/2" 4A186 OBS-4 1 1/2" 1 1/2" 1 3/4"
4A187 ORTHO OR 2 1/2" 1 1/2" 8 3/4" 2 1/2" 1 3/4" 1 1/2" 2 1/2" 4A187 TOILET
4A188
EXIST MECH. 4A188 EXAM AND TREATMENT 1 1/2" 1 1/2" 1 3/4"
4A189 CORR. 4A189 OBS-3 1 1/2" 1 1/2" 1 3/4"
4A190 CLEAN CORE 4A190 TOILET
4A191 STORAGE 4A191 OBS-2 1 1/2" 1 1/2" 1 3/4"
4A192 IMMED. STERILE 4A192 TOILET
4A193 H.A.C. 4A193 OBS-1 1 1/2" 1 1/2" 1 3/4"
4A194 ROBOTICS OR 2 1/2" 1 1/2" 8 3/4" 2 1/2" 1 3/4" 1 1/2" 2 1/2" 4A194 TOILET
4A195 ROB. EQUIP 4A195 H.V.A.C.
4A196 RAD STORAGE 4A196 LOUNGE
4A197 COMP.NET 4A199 LOCKERS
4A198 CORR. 4A198 TOILET
48199 VEST 4A200 TOILET
TOTAL QTY. SCFM QTY. SCFM QTY. SCFM QTY. SCFM QTY. SCFM QTY. SCFM QTY. SCFM 4A201 ADD. STOR.
20 0 16 0 44 0 8 0 4 0 4 0 8 0 4A202 TUB TREAT
4A203 ON CALL BED
4A204 TOILET
4A205 DAY ROOM
4A206 WH. CH. STORAGE
4A207 CCU-1 2 1/2" 1 1/2" 3 3/4"
4A208 CCU-2 2 1/2" 1 1/2" 3 3/4"
4A209 CCU-3 2 1/2" 1 1/2" 3 3/4"
4A210 CCU-4 2 1/2" 1 1/2" 3 3/4"
4A211 MED CABINET
4A212 TOILET
TOTAL QTY. SCFM QTY. SCFM QTY. SCFM
39 0 25 0 53 0
6439 GARNERS FERRY ROAD COLUMBIA, SC
100% BID SET
SAP12/21/2017
WILLIAM JENNINGS BRYAN DORN
VA MEDICAL CENTER
DATE-1DESCRIPTION-1
(706) 774-1020
ING CONSULTING INC
1201 Broad Street, Suite 1-A Augusta, GA 30901
(706) 724-3551
ELECTRICAL DESIGN CONSULTANTS
550 11th Street Augusta, GA 30901
(706) 556-0197
VETERANS 1ST ARCHITECTURE
110-A North Louisville Street Harlem, GA 30814
DATE-2DESCRIPTION-2
DATE-3DESCRIPTION-3
DATE-4DESCRIPTION-4
DATE-5DESCRIPTION-5
DATE-6DESCRIPTION-6
DATE-7DESCRIPTION-7
DATE-8DESCRIPTION-8
DATE-9DESCRIPTION-9
RENOVATE OR SUITE
PLUMBING DETAILS
PL003
C
B
A D
6439 GARNERS FERRY ROAD COLUMBIA, SC
100% BID SET
SAP12/21/2017
WILLIAM JENNINGS BRYAN DORN
VA MEDICAL CENTER
DATE-1DESCRIPTION-1
(706) 774-1020
ING CONSULTING INC
1201 Broad Street, Suite 1-A Augusta, GA 30901
(706) 724-3551
ELECTRICAL DESIGN CONSULTANTS
550 11th Street Augusta, GA 30901
(706) 556-0197
VETERANS 1ST ARCHITECTURE
110-A North Louisville Street Harlem, GA 30814
DATE-2DESCRIPTION-2
DATE-3DESCRIPTION-3
DATE-4DESCRIPTION-4
DATE-5DESCRIPTION-5
DATE-6DESCRIPTION-6
DATE-7DESCRIPTION-7
DATE-8DESCRIPTION-8
DATE-9DESCRIPTION-9
RENOVATE OR SUITE
SANITARY, VENT AND ROOF DRAIN
PIPING DEMOLITION PLANS
PD101
KEY PLAN
6439 GARNERS FERRY ROAD COLUMBIA, SC
100% BID SET
SAP12/21/2017
WILLIAM JENNINGS BRYAN DORN
VA MEDICAL CENTER
DATE-1DESCRIPTION-1
(706) 774-1020
ING CONSULTING INC
1201 Broad Street, Suite 1-A Augusta, GA 30901
(706) 724-3551
ELECTRICAL DESIGN CONSULTANTS
550 11th Street Augusta, GA 30901
(706) 556-0197
VETERANS 1ST ARCHITECTURE
110-A North Louisville Street Harlem, GA 30814
DATE-2DESCRIPTION-2
DATE-3DESCRIPTION-3
DATE-4DESCRIPTION-4
DATE-5DESCRIPTION-5
DATE-6DESCRIPTION-6
DATE-7DESCRIPTION-7
DATE-8DESCRIPTION-8
DATE-9DESCRIPTION-9
RENOVATE OR SUITE
DOMESTIC, HOT AND MED GAS PIPING
DEMOLITION PLANS
PD102
KEY PLAN
Scale: NTS
DETAIL
544-16-100
6439 GARNERS FERRY ROAD COLUMBIA, SC
100% BID SET
MRSLPB36/21/2017DATE-1DESCRIPTION-1
DESCRIPTION-2
DESCRIPTION-3
DESCRIPTION-4
DESCRIPTION-5
DESCRIPTION-6
DESCRIPTION-7
DESCRIPTION-8
DESCRIPTION-9
DATE-2
DATE-3
DATE-4
DATE-5
DATE-6
DATE-7
DATE-8
DATE-9
(706) 774-1020
ING CONSULTING INC
1201 Broad Street, Suite 1-A Augusta, GA 30901
(706) 724-3551
ELECTRICAL DESIGN CONSULTANTS
550 11th Street Augusta, GA 30901
(706) 556-0197
VETERANS 1ST ARCHITECTURE
110-A North Louisville Street Harlem, GA 30814 WILLIAM JENNINGS BRYAN DORN
VA MEDICAL CENTER
12.21.17
Scale: 3/4"=1'-0"
B1, B2 PLATE
Scale: 3/4"=1'-0"
C1, C2 PLATE
S-100
SPECS & E UIPMENT SUPPORT
DETAILS
R
N M
L K
L K
544-16-100
6439 GARNERS FERRY ROAD COLUMBIA, SC
100% BID SET
MRSLPB36/21/2017DATE-1DESCRIPTION-1
DESCRIPTION-2
DESCRIPTION-3
DESCRIPTION-4
DESCRIPTION-5
DESCRIPTION-6
DESCRIPTION-7
DESCRIPTION-8
DESCRIPTION-9
DATE-2
DATE-3
DATE-4
DATE-5
DATE-6
DATE-7
DATE-8
DATE-9
(706) 774-1020
ING CONSULTING INC
1201 Broad Street, Suite 1-A Augusta, GA 30901
(706) 724-3551
ELECTRICAL DESIGN CONSULTANTS
550 11th Street Augusta, GA 30901
(706) 556-0197
VETERANS 1ST ARCHITECTURE
110-A North Louisville Street Harlem, GA 30814 WILLIAM JENNINGS BRYAN DORN
VA MEDICAL CENTER
12.21.17
S-101
S-101
Scale: 1"=1'-0"
DETAIL
4TH FLOOR DETAILS & ROOF
PLAN