36C24718B0637-0003002.pdf
PDF 10 MB Posted
- Attached to
- Renovate Wing 6A Amend release date of solicitation Federal contract opportunity
- Solicitation number
- 36C24718B0637
About this file
36C24718B0637 0003 VA Augusta Report.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24718B0637-0007001.pdf | ||
| 36C24718B0637-0007000.docx | DOCX document | |
| 36C24718B0637-0006001.pdf | ||
| 36C24718B0637-0006000.docx | DOCX document | |
| 36C24718B0637-0005000.docx | DOCX document | |
| 36C24718B0637-0005001.pdf | ||
| 36C24718B0637-0004000.docx | DOCX document | |
| 36C24718B0637-0004002.pdf | ||
| 36C24718B0637-0004001.pdf | ||
| 36C24718B0637-0003001.pdf | ||
| 36C24718B0637-0003003.pdf | ||
| 36C24718B0637-0003000.docx | DOCX document | |
| 36C24718B0637-0002000.docx | DOCX document | |
| 36C24718B0637-0001004.pdf | ||
| 36C24718B0637-0001009.pdf | ||
| 36C24718B0637-0001005.pdf | ||
| 36C24718B0637-0001007.pdf | ||
| 36C24718B0637-0001002.docx | DOCX document | |
| 36C24718B0637-0001003.pdf | ||
| 36C24718B0637-0001006.pdf | ||
| 36C24718B0637-0001008.pdf | ||
| 36C24718B0637-010.docx | DOCX document | |
| 36C24718B0637-001.docx | DOCX document | |
| 36C24718B0637-000.docx | DOCX document |
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA Augusta, Patient Privacy Building 801, Wing 6A DEC Project No. 1609.002
TARGETED SURVEY
FOR ASBESTOS & LEAD-IN PAINT
PATIENT PRIVACY, BUILDING 801, WING 6A
DEPARTMENT OF VETERAN AFFAIRS
AUGUSTA, GEORGIA
Prepared for:
TOLAND<MIZELL<MOLNAR
590 MEANS STREET NW, SUITE 200
ATLANTA, GEORGIA 30318
Report Date:
October 3, 2016
Prepared by:
DURBIN ENVIRONMENTAL CONSULTANTS, INC.
2201 POTOMAC PLACE
LAWRENCEVILLE, GEORGIA 30043
(678) 482-9917
TABLE OF CONTENTS
PAGE
1. INTRODUCTION 3
2. DISCUSSION AND RESULTS 3
a. Asbestos
b. Lead
c. PCBs/Fluorescent Lights
3. METHODOLOGY 5
Asbestos sampling protocol Lead-In-Paint (LBP) sampling protocol
4. OBSERVATIONS/CONCLUSIONS 7
5. RECOMMENDATIONS 8
6. REFERENCES 9
APPENDIX
A. Asbestos Bulk Sampling Summary followed by the Laboratory Report and
Representative Photographs of Suspect Asbestos Containing Materials
B. Paint Chip Sampling Summary followed by the Laboratory Report and Representative
Photographs of Paint Chip Samples
1. INTRODUCTION
Durbin Environmental Consultants, Inc. (DEC) was retained by Toland<Mizell<Molnar, to conduct a hazardous material assessment for suspect asbestos containing materials and lead-in-paint (LBP) at the Department of Veteran Affairs, VA Medical Center, in Augusta, Georgia, in support of the Design Patient Privacy, Building 801, Wing 6A Project. Michael F. Durbin, CIH of Durbin Environmental Consultants, Inc., conducted the hazardous material assessment on September 22, 2016. Mr. Durbin is currently accredited as an asbestos inspector through an Environmental Protection Agency (EPA) approved training provider.
Bulk sample analysis for suspect asbestos containing materials and paint chip sample analysis was performed by SanAir Technologies Laboratory, 1551 Oakbridge Drive, Suite B, Powhatan, VA 23139. SanAir is accredited for asbestos fiber analysis through participation in the National Institute of Standards and Technology (NIST) National Voluntary Laboratory Accreditation Program (NVLAP) and is assigned NVLAP Lab Code 200870-0. San Air utilized the analytical method: EPA/600/R-93/116: "Method for the Determination of Asbestos in Bulk Building Materials” (polarized light microscopy in conjunction with dispersion staining). SanAir analyzed the paint chip samples by Atomic Absorption Spectrophotometer, Flame, following the NIOSH Method 7082. SanAir is accredited by the American Industrial Hygiene Association (AIHA) Laboratory Accreditation Program and is a participant in the Environmental Microbiology & Lead Proficiency Analytical Testing Program (EMPAT) and is assigned Lab Number 162952.
2. DISCUSSION AND RESULTS
a. Building 801, Wing 6A - Asbestos
The asbestos survey was conducted in accordance with the sampling protocol established in the Environmental Protection Agency’s Asbestos Hazard Emergency Response Act (AHERA 40 CFR, Part 763) for the materials included in this specific survey. The following provides general information and summarizes the potential impact of asbestos containing material during the scheduled renovation project.
Bulk samples were collected from the following suspect asbestos containing materials during this survey:
1. Ceiling Tile – White with Small Gouges and Pinholes (HM #1)
2. Ceiling Tile – White with Random Pinholes and Deep Fissures (HM #2)
3. Drywall and Drywall Joint Compound (HM #3)
4. Ceramic Wall Tile and Grout (HM #4)
5. 12” X 12” Green Floor Tile and Associated Mastics, Glues and Adhesives (HM #5)
6. 12” X 12” Blue Floor Tile and Associated Mastics, Glues and Adhesives (HM #6)
7. 12” X 12” Beige Floor Tile and Associated Mastics, Glues and Adhesives (HM #7)
8. Brown Covebase and Associated Adhesive (HM #8)
9. Light Tan Covebase and Associated Adhesive (HM #9)
10. Beige Spray Applied Fireproofing (HM #10)
11. Red Fire Safe Material (HM #11)
12. Foil Wrapped Duct Insulation with White Mastic (HM #12)
13. Paper Wrapped Duct Insulation with White Mastic (HM #13)
14. Paper Wrapped Pipe Insulation over Fiberglass (HM #14)
15. Fire Door Insulation (HM #15)
The following collected bulk sample material contained asbestos by Polarized Light Microscopy (PLM) (reference Appendix A for the Asbestos Bulk Sampling Summary followed by the Laboratory Report and Representative Photographs of Suspect Asbestos Containing Materials).
1. 12” X 12” Green Floor Tile and Associated Mastics, Glues and Adhesives (HM #5)
2. 12” X 12” Blue Floor Tile and Associated Mastics, Glues and Adhesives (HM #6)
3. 12” X 12” Beige Floor Tile and Associated Mastics, Glues and Adhesives (HM #7)
b. Building 801, Wing 6A - Lead
Paint chip samples were collected from the following representative surfaces:
1. Beige Paint on Metal Door Frame, Mechanical Room 6A-134 (Sample # 6A-PC-01)
2. Beige Paint on Metal Door, Mechanical Room 6A-134 (Sample # 6A-PC-02)
3. Beige Paint on Metal Door, Room 6A-143 (Sample # 6A-PC-03)
All of the representative painted surfaces sampled in Building 801, Wing 6A in areas that will be impacted by the scheduled renovation project had detectable levels of lead via Flame Atomic Absorption Spectrophotometry. Additionally, Sample #6A-PC-01 had paint above the HUD/EPA definition of Lead-Based Paint (LBP) of equal to or greater than 0.5% by weight.
The Occupational Safety and Health Administration (OSHA) Construction Industry Standard for Lead (29 CFR 1926.62) does not reference the HUD definition for LBP. If detectable levels of lead are identified in any painted surface, paint disturbance will fall under the OSHA Lead Standard. OSHA 29 CFR 1926.62 requires employers to perform exposure monitoring for employees whose tasks disturb or potentially disturb lead. The data contained in this survey report should be provided to the Contractor, prior to the Contractor submitting bids for maintenance, renovation or demolition work. The Contractor shall assume that all painted surfaces may contain detectable levels of lead for purposes of this project and demonstrate through personal air sampling that airborne lead levels will not exceed 30 micrograms (ug) lead per cubic meter (m3) of air determined as an 8-hour time-weighted average (TWA), for each representative task and trade that disturbs painted surfaces.
Refer to Appendix B for the Paint Chip Sample Summary followed by Laboratory Data and Representative Photographs of Paint Chip Samples.
c. Building 801, Wing 6A - PCBs/Fluorescent Lights
The construction date of Building 801, Wing 6A was not known on the day of the inspection.
All ballasts installed or manufactured prior to 1978, should be assumed to contain PCBs unless specifically labeled as having no PCBs.
Additionally, the fluorescent lights and high intensity discharge bulbs (HID) should be assumed to contain mercury.
All known or assumed PCB ballasts should be handled in accordance with 40 CFR Part 761 Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions.
All mercury vapor light fixtures should be handled in accordance with 40 CFR Part 273 Standards for Universal Waste Management.
3. METHODOLOGY
Asbestos Sampling Protocol
The inspector sampled all suspect ACM in accessible areas. In order for a group of homogeneous materials to be considered as non-asbestos containing, all samples from that specific homogeneous material must be analyzed and determined to be non-asbestos containing or less than or equal to 1% asbestos.
Representative, randomly selected samples were collected from each homogeneous area of suspect asbestos-containing material. For purposes of this report, the homogeneous area is physically defined as all material with the same visual appearance, texture and hardness.
The minimum number of samples collected for each homogeneous area (or material) is as follows:
1. Friable Spray-applied or Trowel-applied Material
a. Less than or equal to 1000 square feet (S.F.) = 3 samples
b. Greater than 1000 S.F. and less than or equal to 5000 S.F. = 5 samples.
c. Greater than 5000 S. F. = 7 samples
2. Pipe and Duct Insulation
Three samples per homogeneous area of insulation were taken unless it was a confirmation sample.
3. Elbows, Valves, Fittings and Connection Mud
Three representative samples were taken from each representative type of insulated elbow, valve, fitting and connecting mud unless it was a confirmation sample.
4. Boiler, Tanks and Furnaces
A minimum of 3 samples per unit was collected.
5. Patchwork Patchwork is defined as a patch or repair to existing material based on the following quantities:
a. Surfacing material patches are limited to a maximum of 6 S. F.
b. Pipe and duct insulation patches are limited to a maximum of 6 L. F. or 6
S. F.
c. Boiler, tanks and furnace patches are limited to 6 S.F. maximum.
If the patchwork exceeded the limits prescribed above, the sampling protocol resorted back to the homogeneous area descriptions in items 1-4. If a material qualifies as patchwork, a single sample was collected per patch.
6. Ceiling or Acoustical Tile
a. Minimum of 3 Samples
7. Miscellaneous Friable Material
a. 3 Samples
8. Non-friable Material
Non-friable materials for purposes of this survey would include material such as floor tiles and mastic/adhesive, linoleum floor covering, interior/exterior caulks, flooring felt (if still under floor tile), roofing materials, miscellaneous cementitious material such as wall or ceiling panels, caulking or sealant, or window glazing. Note: All materials below the suspended ceiling system such as floor tile, was excluded from this survey.
a. Minimum of 3 samples
Lead-Based Paint (LBP) Sampling Protocol
Paint chips containing lead concentrations at or above 0.5 percent by weight are considered positive for lead based on EPA and Department of Housing and Urban Development (HUD) guidelines for Target Housing and Child Occupied Facilities.
The inspector collected paint chip samples from representative surfaces and components likely to be impacted by any renovation project and compared them against the HUD definition for Lead- Based Paint (LBP) of 0.5 % by weight. Individual sample results are presented in tabular form in Appendix B.
The Occupational Safety and Health Administration (OSHA) Construction Industry Standard for Lead (29 CFR 1926.62) does not reference the HUD definition for LBP. If detectable levels of lead are identified in any painted surface, paint disturbance will fall under the OSHA Lead Standard. OSHA 29 CFR 1926.62 requires employers to perform exposure monitoring for employees whose tasks disturb or potentially disturb lead. The data contained in this survey report should be provided to the Contractor, prior to the Contractor submitting bids for maintenance, renovation or demolition work. The Contractor shall assume that all painted surfaces may contain detectable levels of lead for purposes of this project and demonstrate through personal air sampling that airborne lead levels will not exceed 30 micrograms (ug) lead per cubic meter (m3) of air determined as an 8-hour time-weighted average (TWA), for each representative task and trade that disturbs painted surfaces.
4. OBSERVATIONS/CONCLUSIONS
Building 801, Wing 6A - Asbestos
The following collected bulk sample material contained asbestos by Polarized Light Microscopy (PLM) (reference Appendix A for the Asbestos Bulk Sampling Summary followed by the Laboratory Report and Representative Photographs of Suspect Asbestos Containing Materials).
1. 12” X 12” Green Floor Tile and Associated Mastics, Glues and Adhesives (HM #5)
2. 12” X 12” Blue Floor Tile and Associated Mastics, Glues and Adhesives (HM #6)
3. 12” X 12” Beige Floor Tile and Associated Mastics, Glues and Adhesives (HM #7)
Building 801, Wing 6A - Lead
All of the representative painted surfaces sampled in Building 801, Wing 6A in areas that will be impacted by the scheduled renovation project had detectable levels of lead via Flame Atomic Absorption Spectrophotometry. Additionally, Sample #6A-PC-01 had paint above the HUD/EPA definition of Lead-Based Paint (LBP) of equal to or greater than 0.5% by weight.
Disturbance to any painted item/surface/component shall be done in compliance with the OSHA Construction Industry Standard for Lead (29 CFR 1926.62). The Occupational Safety and Health Administration (OSHA) Construction Industry Standard for Lead (29 CFR 1926.62) does not reference the HUD definition for LBP. If detectable levels of lead are identified in any painted surface, paint disturbance will fall under the OSHA Lead Standard. OSHA 29 CFR
1926.62 requires employers to perform exposure monitoring for employees whose tasks disturb or potentially disturb lead. The data contained in this survey report should be provided to the Contractor, prior to the Contractor submitting bids for maintenance, renovation or demolition work. The Contractor shall assume that all painted surfaces may contain detectable levels of lead for purposes of this project and demonstrate through personal air sampling that airborne lead levels will not exceed 30 micrograms (ug) lead per cubic meter (m3) of air determined as an 8-hour time-weighted average (TWA), for each representative task and trade that disturbs painted surfaces.
Building 801, Wing 6A – PCBs/Fluorescent Lights
The construction date of Building 801, Wing 6A was not known on the day of the survey. All ballasts installed or manufactured prior to 1978, should be assumed to contain PCBs unless specifically labeled as having no PCBs.
Additionally, the fluorescent lights and high intensity discharge bulbs (HID) should be assumed to contain mercury.
All known or assumed PCB ballasts should be handled in accordance with 40 CFR Part 761 Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions.
All mercury vapor light fixtures should be handled in accordance with 40 CFR Part 273 Standards for Universal Waste Management.
5. RECOMMENDATIONS
A. The asbestos containing material survey report should be maintained at the job site during performance of the construction activities. At least ten (10) working days advanced written NESHAPS Notification to Georgia Department of Natural Resources, Environmental Protection Division, Air Protection Branch/Air Quality Control Section, Attention: Asbestos and Lead Program, 4244 International Parkway, Suite 104, Phone: (404) 363-7026/Fax:
(404) 363-7100 and EPD Asbestos Fees Lockbox, Post Office Box 101173, Atlanta, Georgia 30392 is required for renovation work on this project.
B. Communication of this asbestos survey report results should be presented in accordance with the OSHA 29 CFR 1926.1101 Asbestos Standard to all personnel who may enter or perform work in Building 801, Wing 6A.
C. Disturbance of painted surfaces should be performed in accordance with the OSHA Lead
Standard (29 CFR 1926.62). Waste generated by disturbance of painted surfaces should be subjected to Toxicity Characteristic Leaching Procedure (TCLP) testing to determine leachable lead concentrations. If leachable concentrations of lead in construction waste are determined by TCLP testing, those materials should be disposed of in accordance with 40 CFR Part 260 to 271.
D. Remove and dispose of all PCB ballasts in accordance with 40 CFR Part 761 Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions, and other applicable Federal, State and Local Regulations.
E. Remove and dispose of (or recycle) all mercury vapor light fixtures in accordance with 40
CFR Part 273 Standards for Universal Waste Management and other applicable Federal, State and Local Regulations.
6. REFERENCES
1. Guidance for Controlling Asbestos-Containing Materials in Buildings”
(Purple Book). EPA 560/5-85-024. Office of Pesticides and Toxic Substances Washington, DC 20460.
2. 40 CFR, Part 763, Asbestos Hazard Emergency Response Act
3. 40 CFR, Part 763, Asbestos School Hazard Abatement Reauthorization Act
4. 40 CFR, Part 61, Subpart M Asbestos
5. 29 CFR Part 1926.1101 Asbestos
6. 29 CFR Part 1926.62 Lead
7. HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing
8. 40 CFR Part 260 General Hazardous Waste Management.
9. 40 CFR Part 261 Identification and Listing of Hazardous Waste.
10. 40 CFR Part 262 Standards Applicable to Generators of Hazardous Waste.
11. 40 CFR Part 263 Standards Applicable to Transporters of Hazardous Waste.
12. 40 CFR Part 268 Land Disposal Restrictions.
13. 40 CFR Part 761 Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions.
14. 40 CFR Part 273 Standards for Universal Waste Management
15. State of Georgia Solid Waste Management (391-3-4) and Hazardous Waste Management
(391-3-11) Rules.
If you have any questions or comments regarding this report, please do not hesitate to call.
Sincerely, Durbin Environmental Consultants, Inc.
Michael F. Durbin, CIH Michael F. Durbin, CIH (EPA-Accredited Asbestos Inspector/Management Planner, Certificate Number 15694, Expiration Date: May 23, 2017) President
APPENDIX A
Asbestos Bulk Sampling Summary
Followed by the Laboratory Data and Representative Photographs of Suspect Asbestos Containing Materials
Sample Number
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
6A-CT1-01
Ceiling Tile – White with Small Gouges and Pinholes
NAD N/A See Lab Report
Building 801, Wing 6A, C6-
C8 Nurses Station
6A-CT1-02
Ceiling Tile – White with Small Gouges and Pinholes
NAD N/A See Lab Report
Building 801, Wing 6A, Corridor
Outside Room 6A-135
6A-CT1-03
Ceiling Tile – White with Small Gouges and Pinholes
NAD N/A See Lab Report
Building 801, Wing 6A, Corridor
Outside Room 6A-109
6A-CT2-01
Ceiling Tile – White with Random Pinholes and Deep Fissures
NAD N/A See Lab Report
Building 801, Wing 6A, Room
6A-145
6A-CT2-02
Ceiling Tile – White with Random Pinholes and Deep Fissures
NAD N/A See Lab Report
Building 801, Wing 6A, Room
6A-111
6A-CT2-03
Ceiling Tile – White with Random Pinholes and Deep Fissures
NAD N/A See Lab Report
Building 801, Wing 6A, Room
6A-151
6A-DWJC-
Drywall and Drywall Joint Compound NAD N/A See Lab
Report Building 801, Wing 6A, C6-
6A-DWJC-
Drywall and Drywall Joint Compound NAD N/A See Lab
Report
Building 801, Wing 6A, Corridor
Outside Room 6A-135
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
6A-DWJC-
Drywall and Drywall Joint Compound NAD N/A See Lab
Report Building 801, Wing 6A, Room 6A-134
6A-DWJC-
Drywall and Drywall Joint Compound NAD N/A See Lab
Report
Building 801, Wing 6A, Room
6A-122
Drywall and Drywall Joint Compound NAD N/A See Lab
Report
Building 801, Wing 6A, Room
6A-113
6A-DWJC-
Drywall and Drywall Joint Compound NAD N/A See Lab
Report
Building 801, 6A-154
Drywall and Drywall Joint Compound NAD N/A See Lab
Report
Building 801, 6A-164
6A-CER-01 Ceramic Wall Tile and Grout NAD N/A See Lab
Report
Building 801, 6A-143
6A-CER-02 Ceramic Wall Tile and
Report
Building 801, Wing 6A, Corridor Near Stair 2
6A-CER-03 Ceramic Wall Tile and
Report
Building 801, Wing 6A, Vestibule Near Room 6A-130A
6A-CER-04 Ceramic Wall Tile and Grout NAD N/A See Lab
Report
Building 801, 6A-135
6A-CER-05 Ceramic Wall Tile and
Report
Building 801, Wing 6A, Corridor Near Room 6A-105A
6A-FT1-01
12” X 12” Green Floor
Tile and Associated Mastics, Glues and
Adhesives
3% Chrysotile in Black Mastic
No See Lab Report
Building 801, Wing 6A, C6-
C8 Nurses
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
6A-FT1-02
12” X 12” Green Floor
Tile and Associated Mastics, Glues and
Adhesives
3% Chrysotile in Black Mastic
No See Lab Report
Building 801, Wing 6A, C6-
6A-FT1-03
12” X 12” Green Floor
Tile and Associated Mastics, Glues and
Adhesives
3% Chrysotile in Black Mastic
No See Lab Report
Building 801, Wing 6A, C6-
C8 Nurses Station
6A-FT2-01
12” X 12” Blue Floor Tile and Associated Mastics, Glues and
Adhesives
3% Chrysotile in Black Mastic
No See Lab Report
Building 801, Wing 6A, C6-
6A-FT2-02
12” X 12” Blue Floor Tile and Associated Mastics, Glues and
Adhesives
3% Chrysotile in Black Mastic
No See Lab Report
Building 801, Wing 6A, C6-
C8 Nurses Station
6A-FT2-03
12” X 12” Blue Floor Tile and Associated Mastics, Glues and
Adhesives
3% Chrysotile in Black Mastic
No See Lab Report
Building 801, Wing 6A, C6-
6A-FT3-01
12” X 12” Beige Floor
Tile and Associated Mastics, Glues and
Adhesives
2% Chrysotile Floor Tile;
3% Chrysotile in Black Mastic
No See Lab Report
Building 801, 6A-113
6A-FT3-02
12” X 12” Beige Floor
Tile and Associated Mastics, Glues and
Adhesives
2% Chrysotile Floor Tile;
3% Chrysotile in Black Mastic
No See Lab Report
Building 801, Wing 6A, Room
6A-154
6A-FT3-03
12” X 12” Beige Floor
Tile and Associated Mastics, Glues and
Adhesives
2% Chrysotile Floor Tile;
3% Chrysotile in Black Mastic
No See Lab Report
Building 801, 6A-145
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
6A-CB1-01 Brown Covebase and Associated Adhesive NAD N/A See Lab
Report
Building 801, Wing 6A, Corridor
6A-146A
6A-CB1-02 Brown Covebase and Associated Adhesive NAD N/A See Lab
Report
Building 801, Wing 6A, Corridor
Outside Room 6A-164A
6A-CB1-03 Brown Covebase and Associated Adhesive NAD N/A See Lab
Report
Building 801, Wing 6A, Vestibule Near Room 6A-130
6A-CB2-01
Light Tan Covebase and Associated Adhesive
NAD N/A See Lab Report
Building 801, 6A-134
6A-CB2-02
Light Tan Covebase and Associated Adhesive
NAD N/A See Lab Report
Building 801, Wing 6A, C6-
C8 Nurses Station
6A-CB2-03
Light Tan Covebase and Associated Adhesive
NAD N/A See Lab Report
Building 801, Wing 6A, C6-
6A-FP-01 Beige Spray Applied Fireproofing NAD N/A See Lab
Report
Building 801, Wing 6A, Corridor
6A-FP-02 Beige Spray Applied
Report
Building 801, 6A-FP-03 Beige Spray Applied
Report
Building 801, Wing 6A, C6-
C8 Nurses Station
6A-FP-04 Beige Spray Applied Fireproofing NAD N/A See Lab
Report
Building 801, 6A-119
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
6A-FP-05 Beige Spray Applied Fireproofing NAD N/A See Lab
Report
Building 801, 6A-151
6A-FP-06 Beige Spray Applied
Report
Building 801, Wing 6A, Vestibule Near Room 6A-154
6A-FP-07 Beige Spray Applied Fireproofing NAD N/A See Lab
Report
Building 801, 6A-111
6A-FS-01 Red Fire Safe Material NAD N/A See Lab Report
Building 801, Wing 6A, Corridor
6A-109
6A-FS-02 Red Fire Safe Material NAD N/A See Lab
Building 801, Wing 6A, Corridor
Outside Room 6A-135
6A-FS-03 Red Fire Safe Material NAD N/A See Lab Report
Building 801, 6A-DM1-01
Foil Wrapped Duct
Insulation with White Mastic
NAD N/A See Lab Report
Building 801, 6A-DM1-02
Foil Wrapped Duct
Insulation with White Mastic
NAD N/A See Lab Report
Building 801, Wing 6A, Room
6A-134
6A-DM1-03
Foil Wrapped Duct
Insulation with White Mastic
NAD N/A See Lab Report
Building 801, 6A-DI2-01
Paper Wrapped Duct Insulation with White
Mastic NAD N/A See Lab
Report
Building 1, Attic – Between Structural Steel and Metal Deck
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
6A-DI2-02
Paper Wrapped Duct Insulation with White
Mastic NAD N/A See Lab
Report
Building 1, Attic – Between Structural Steel and Metal Deck
6A-DI2-03
Paper Wrapped Duct Insulation with White
Mastic NAD N/A See Lab
Report
Building 801, Wing 6A, Room
6A-134
6A-PI1-01
Paper Wrapped Pipe
Insulation over Fiberglass
NAD N/A See Lab Report
Building 801, 6A-PI1-02
Paper Wrapped Pipe
Insulation over Fiberglass
NAD N/A See Lab Report
Building 801, 6A-PI1-03
Paper Wrapped Pipe
Insulation over Fiberglass
NAD N/A See Lab Report
Building 801, Wing 6A, Room
6A-134
6A-PI1-04
Paper Wrapped Pipe
Insulation over Fiberglass
NAD N/A See Lab Report
Building 801, 6A-FD-01 Fire Door Insulation NAD N/A See Lab
Building 801, Wing 6A, Room
NAD – No Asbestos Detected; N/A – Not Applicable
Representative Photographs of Suspect Asbestos Containing
Materials
1. Ceiling Tile – White with Small Gouges and Pinholes (HM #1)
2. Ceiling Tile – White with Random Pinholes and Deep Fissures (HM #2)
3. Drywall and Drywall Joint Compound (HM #3)
4. Ceramic Wall Tile and Grout (HM #4)
5. 12” X 12” Green Floor Tile and Associated Mastics, Glues and Adhesives (HM #5)
6. 12” X 12” Blue Floor Tile and Associated Mastics, Glues and Adhesives (HM #6)
7. 12” X 12” Beige Floor Tile and Associated Mastics, Glues and Adhesives (HM #7)
8. Brown Covebase and Associated Adhesive (HM #8)
9. Light Tan Covebase and Associated Adhesive (HM #9)
10. Beige Spray Applied Fireproofing (HM #10)
11. Red Fire Safe Material (HM #11)
12. Foil Wrapped Duct Insulation with White Mastic (HM #12)
13. Paper Wrapped Duct Insulation with White Mastic (HM #13)
14. Paper Wrapped Pipe Insulation over Fiberglass (HM #14)
15. Fire Door Insulation (HM #15)
APPENDIX B
Paint Chip Sample Summary Table Followed by Laboratory Data and Representative Photographs of Paint Chip Samples
Collection Date
Sample Number
Description Location Analytical Method
Percent Lead by Weight
(wt%)
9/22/16 6A-PC-01 Beige Paint
Metal Door Frame, Mechanical Room 6A-134
AAS 0.5874
9/22/16 6A-PC-02 Beige Paint Metal Door, Mechanical
Room 6A-134
AAS 0.0289
9/22/16 6A-PC-03 Beige Paint Metal Door, Room 6A-143 AAS 0.028
BRL: Not Detected at the Reporting Limit
Representative Photographs of Paint Chip Samples
1. Beige Paint on Metal Door Frame, Mechanical Room 6A-134 (Sample # 6A-PC-01)
2. Beige Paint on Metal Door, Mechanical Room 6A-134 (Sample # 6A-PC-02)
3. Beige Paint on Metal Door, Room 6A-143 (Sample # 6A-PC-03)