th re e i n c h e s o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t 1 2 3 4 5
Drawing Title:Seal:
ARCHITECT / ENGINEERS:
Project Title:
Date:
Project Number:
Drawing Number:
Drawn:Checked:
Building Number:
D C
B A
Revisions:
8016 TOWER POINT DRIVE
CHARLOTTE, NC 28227
P 704.814.1320 F 704.321.0833
Project Phase:
D C
B A
1 2 3 4 5 6
Location:
CONSULTANTS:
Office of
Construction and Facilities
Management
LRSPC #16910
C:\Users\jlorch\Documents\16910 VAMC Clarksburg Parking Deck-Structural_jlorch.rvt
HDG PROJECT: 16013 S001
STRUCTURAL GENERAL NOTES
CONSTRUCTION DOCUMENTS 100%
CONSTRUCT PARKING
STRUCTURE
MAY 14, 2018 JARMSR
LOUIS A. JOHNSON VAMC
540-320
1.1
1.0. CODES AND STANDARDS:
1.1. INTERNATIONAL BUILDING CODE 2009 EDITION INCLUDING ALL SUBSEQUENT
SUPPLEMENTS AND AMENDMENTS THERETO.
1.2. "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES", AMERICAN
SOCIETY OF CIVIL ENGINEERS, ASCE 7-05.
1.3. "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS", PUBLICATION 360-05 BY THE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION, AND AS AMENDED IN SPECIFICATIONS.
1.4. "SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS", PUBLICATION 341-05 BY
THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION INCLUDING SUPPLEMENT NO. 1
DATED 2005.
1.5. "STRUCTURAL WELDING CODE - STEEL (AWS D1.1-04)" AND "STRUCTURAL WELDING
CODE REINFORCING STEEL (AWS D1.4-98)", AMERICAN WELDING SOCIETY.
1.6 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-08)",
AMERICAN CONCRETE INSTITUTE AND ALL SUCCEEDING REVISIONS.
1.7. ACI 423 COMMITTEE REPORT "RECOMMENDATIONS FOR CONCRETE MEMBERS PRESTRESSED
WITH UNBONDED TENDONS".
1.8. "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530-08) AND
"SPECIFICATIONS FOR MASONRY STRUCTURES" (ACI 530.1-08), AMERICAN CONCRETE
INSTITUTE.
1.9. "MANUAL OF STANDARD PRACTICE", CONCRETE REINFORCING STEEL INSTITUTE,
LATEST EDITION.
2.0. SPECIFICATIONS:
2.1. THE STRUCTURAL GENERAL NOTES ARE NOT A SUBSTITUTE OR A REPLACEMENT
FOR THE PROJECT SPECIFICATIONS. THESE NOTES ARE INTENDED AS A GUIDE TO
THE DESIGN AND/OR CONSTRUCTION REQUIREMENTS ESTABLISHED FOR THIS PROJECT.
NO CONTRACTOR SHOULD ATTEMPT TO DESIGN, BID, OR CONSTRUCT ANY PORTION OF
THE WORK HEREIN WITHOUT CONSULTING THE PROJECT SPECIFICATIONS. WHERE
CONFLICTS OCCUR BETWEEN THESE NOTES AND THE SPECIFICATIONS, THE MORE
STRINGENT REQUIREMENT SHALL APPLY UNLESS A WRITTEN CLARIFICATION IS
ISSUED BY THE COR.
3.0. DESIGN LOADS:
3.1. SUPERIMPOSED GRAVITY LOADS:
AREA LIVE LOAD DEAD LOAD
MINIMUM UNIFORM ROOF LOAD 30 PSF 20 PSF
STAIRS 100 PSF -
ALL FRAMED FLOORS, U.N.O. 40 PSF 5 PSF
SLAB ON GRADE 200 PSF -
LIVE LOADS ARE REDUCED IN CONFORMANCE WITH ASCE 7-05
SECTION 4.8 "REDUCTION IN LIVE LOADS"
3.2. SEISMIC LOADS:
OCCUPANCY CATEGORY II
OCCUPANCY IMPORTANCE FACTOR "IE" 1.00
SITE SOIL CLASSIFICATION D
MAPPED SPECTRAL RESPONSE "Ss/S1" 0.187g/0.068g DESIGN SPECTRAL RESPONSE "Sds/Sd1" 0.199g/0.108g
SEISMIC DESIGN CATEGORY B
MEAN ROOF HEIGHT 36'-0"
STRUCTURAL SYSTEM NORTH/SOUTH EAST/WEST
ORDINARY PRECAST ORDINARY PRECAST
SHEAR WALLS SHEAR WALLS
RESPONSE MODIFICATION "R" 4.0 4.0
DEFLECTION AMPLIFICATION "CD" 4.0 4.0
PERIOD BY CODE FORMULA "TA" 0.283 SEC. 0.283 SEC.
PERIOD BY ELASTIC ANALYSIS "TE" 0.385 SEC. 0.185 SEC.
MAXIMUM PERMISSIBLE PERIOD "TU" 0.476 SEC. 0.476 SEC.
SEISMIC COEFFICIENT "CS" 0.050 0.050
SEISMIC BASE SHEAR "VO" 378.82 KIPS 378.82 KIPS
3.3. WIND LOADS PER ASCE 7-05:
BASIC WIND SPEED (3-SECOND GUST) 90 MPH
OCCUPANCY CATEGORY II
IMPORTANCE FACTOR "I" 1.00
ASCE 7 EXPOSURE CATEGORY B
MEAN ROOF HEIGHT 36'-0"
MAIN WIND FORCE RESISTING SYSTEM NORTH/SOUTH EAST/WEST
ORDINARY PRECAST ORDINARY PRECAST
SHEAR WALLS SHEAR WALLS
WINDWARD PRESSURE COEFFICIENT "CP" +0.80 +0.80
LEEWARD PRESSURE COEFFICIENT -0.50 -0.50
WIND BASE SHEAR "VO" 106.27 KIPS 59.21 KIPS
WIND PRESSURES FOR CLADDING AND OTHER COMPONENTS VARY WITH SHAPE
FACTORS FOR THOSE COMPONENTS - SEE APPROPRIATE ASCE 7-05 SECTIONS
3.4. DRIFTING SNOW LOADS PER ASCE 7-05:
50 YEAR GROUND SNOW LOAD "PG" 30.0 PSF
OCCUPANCY CATEGORY II
IMPORTANCE FACTOR "I" 1.00
ROOF EXPOSURE TYPE PARTIAL
EXPOSURE FACTOR "CE" 1.00
THERMAL FACTOR "CT" 1.20
MINIMUM ROOF SNOW LOAD (PG*I) 30.0 PSF
FLAT ROOF SNOW LOAD "PF" 25.2 PSF
RAIN-ON-SNOW SURCHAGE N/A
FLAT ROOF DESIGN SNOW LOAD 25.2 PSF
4.0. FOUNDATIONS:
4.1. FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL REPORT, DATED FEBRUARY 2017
BY NGE. THIS REPORT IS AVAILABLE FOR INSPECTION AT
THE OFFICE OF THE COR. THE RECOMMENDATIONS OF THIS "REPORT"
ARE HEREIN MADE A PART OF THE REQUIREMENTS OF THESE CONTRACT DOCUMENTS.
4.2. DRILLED PIERS:
A. SHALL BEAR ON STRATA CAPABLE OF SUSTAINING A MINIMUM BEARING PRESSURE
OF 15 KSF AND A SIDE SHEAR VALUE OF 1.2 KSF FOR THE ROCK SOCKET.
B. BOTTOM OF PIER (FOUNDING) ELEVATIONS SHOWN ON THE DRAWINGS ARE ESTIMATES
FOR BIDDING PURPOSES ONLY. ACTUAL ELEVATIONS WILL BE DETERMINED IN THE
FIELD.
C. ALL PIERS SHALL BE SOCKETED A MINIMUM OF 10'-0" INTO CLAYSTONE AND/OR
SHALE BEDROCK ACCORDANCE WITH THE GEOTECHNICAL REPORT. ACTUAL SOCKET
LENGTHS ARE SHOWN ON THE PLANS. THIS LENGTH IS INCLUDED IN THE
ESTIMATED FOUNDING ELEVATION NOTED ON THE DRAWINGS.
D. ALL PIERS EXCAVATIONS SHALL HAVE A 2" DIAMETER TEST HOLE DRILLED TO A
DEPTH OF 1.5 TIMES THE PIER DIAMETER, HOWEVER NOT LESS THAN FIVE (5) FEET
NOR GREATER THAN TEN (10) FEET BELOW THE FOUNDING ELEVATION. TEST HOLE
MAY BE OMITTED ONLY WITH THE APPROVAL OF THE GEOTECHNICAL ENGINEER AND IF
OMITTED, SHALL BE CREDITED TO THE OWNER IN ACCORDANCE WITH "UNIT PRICES".
E. DRILLING MACHINES SHALL BE EQUIPPED WITH ROCK AUGERS WITH CARBIDE TEETH
FOR UNCLASSIFIED NORMAL MACHINE EXCAVATION AT NO EXTRA COST TO THE OWNER.
4.3. TESTING AND INSPECTION:
A. ALL AREAS TO HAVE SLABS ON GRADE SHALL BE PROOF ROLLED IN ACCORDANCE WITH
THE "REPORT" AND UNDER OBSERVATION OF THE GEOTECHNICAL ENGINEER AND
APPROVED PRIOR TO PREPARATION FOR CONCRETE PLACEMENT.
AND APPROVED PRIOR TO PREPARATION FOR CONCRETE PLACEMENT.
B. ALL FOUNDING STRATA SHALL BE INSPECTED AND APPROVED BY
THE GEOTECHNICAL ENGINEER PRIOR TO ANY CONCRETE PLACEMENT.
C. GEOTECHNICAL ENGINEER SHALL BE THE SOLE JUDGE AS TO SUITABILITY OF ALL
FOUNDATION AND/OR SLAB BEARING/FOUNDING STRATA.
D. DRILLED PIER BEARING ELEVATIONS SHALL BE ADJUSTED IN THE FIELD AS
REQUIRED TO MEET THE DESIGN BEARING PRESSURES BY ADDITIONAL DRILLING,
ROCK SOCKETING (WHERE PERMITTED BY THE DRAWINGS), OR BY OTHER MEANS
ACCEPTABLE TO THE GEOTECHNICAL ENGINEER AND APPROVED BY THE STRUCTURAL
ENGINEER.
E. ALL OPERATIONS SHALL BE PERFORMED BY THE CONTRACTOR IN ACCORDANCE WITH
THE SPECIFICATION REQUIREMENTS AND UNIT PRICES.
4.4 . UNACCEPTABLE SOILS: CONTRACTOR SHALL REMOVE AND REPLACE UNACCEPTABLE
SOILS IN ACCORDANCE WITH THE GEOTECHNICAL REPORT AND/OR AT THE DIRECTION
OF THE GEOTECHNICAL ENGINEER. ALL SOILS WITH PLASTICITY INDICES GREATER
THAN 15 OF WHICH MORE THAN 10% PASSES A #200 SIEVE SHALL BE REMOVED TO A
DEPTH OF NOT LESS THAN 3'-0" OR GREATER AS DIRECTED BY THE GEOTECHNICAL
ENGINEER WHERE SUCH MATERIAL OCCURS BELOW FOUNDATIONS.
4.5 . ROCK EXCAVATION: DENSE SOIL AND PARTIALLY WEATHERED ROCK MAY REQUIRE
HEAVY EXCAVATING EQUIPMENT WITH RIPPING TOOLS FOR REMOVAL. CONFINED
EXCAVATIONS (FOOTINGS, UTILITY TRENCHES, ETC.) MAY REQUIRE RIPPING TOOLS
AND PNEUMATIC HAMMERS. LIGHT BLASTING MAY BE REQUIRED TO EFFICIENTLY REMOVE
LARGE BOULDERS AND MATERIAL RESISTANT TO RIPPING AND PNEUMATIC HAMMERS.
PRIOR TO ANY PROPOSED BLASTING THE CONTRACTOR SHALL OBTAIN APPROVAL AND
COORDINATE HIS ACTIVITIES WITH THE OWNER AND ALL GOVERNING AUTHORITIES.
4.6 . ENGINEERED FILL: ALL FILL MATERIAL SHALL BE SELECTED IN ACCORDANCE WITH THE
GEOTECHNICAL REPORT. MATERIAL SHALL BE A CLEAN, LOW PLASTIC SOIL WITH A
PLASTICITY INDEX LESS THAN 30 (LESS THAN 15 IS PREFERRED), LIQUID LIMIT LESS
THAN 50, UNIT WEIGHT OF 120 PCF (+/- 5 PCF), AND SHALL NOT CONTAIN MORE THAN
5% BY WEIGHT OF FIBROUS ORGANIC MATERIALS. PARTIALLY WEATHERED ROCK
MATERIALS MAY BE USED FOR STRUCTURAL FILL PROVIDED THE MATERIAL CAN REDUCED
TO MAXIMUM DIMENSIONS OF 6".
4.7. DEEP FILL: WHERE SEVERAL FEET OF STRUCTURAL FILL WILL BE REQUIRED TO ACHIEVE
THE FINAL GRADES, CONSTRUCTION SHALL BE DELAYED TO PERMIT THE UNDERLYING SOILS
SETTLE AND CONSOLIDATE UNDER THE WEIGHT OF THE NEWLY PLACED FILL OVERBURDEN.
SEVERAL WEEKS OF TIME MAY BE REQUIRED FOR THIS SETTLING TO OCCUR. SETTLEMENT
PINS SHALL BE INSTALLED AT THE TOP OF THE FILL AND MONITORED TO DETERMINE
WHEN THE CONSOLIDATION HAS REACHED A NEGLIGIBLE MOVEMENT THUS PERMITTING
CONSTRUCTION TO BEGIN. THE GEOTECHNICAL ENGINEER SHALL BE THE SOLE JUDGE AS
TO THE REQUIREMENTS FOR DELAY AND COMPLETION OF ADEQUATE CONSOLIDATION.
4.8 . EXTENT OF FILL PLACEMENT: STRUCTURAL FILL SHALL EXTEND HORIZONTALLY BEYOND
THE EDGE OF BUILDING FOUNDATIONS AT LEAST A DISTANCE OF 10'-0" BUT NOT LESS
THAN THE HEIGHT OF THE FILL MATERIAL PLACED. SLOPES AT PERMANENT CUTS SHOULD
NOT EXCEED 2:1 (H:V). SLOPE AT PERMANENT FILLS SHOULD NOT EXCEED 2.5:1 (H:V)
AND SHOULD BE PROPERLY COMPACTED.
4.9 . COMPACTION: ALL FILL SHALL BE PLACED IN LOOSE LIFTS NOT EXCEEDING 8 INCHES
IN THICKNESS AND COMPACTED TO A MINIMUM OF 95 PERCENT STANDARD PROCTOR (ASTM
D-698) EXCEPT THAT THE TOP 12 INCHES UNDER FOUNDATIONS AND THE BUILDING PAD
SHALL BE COMPACTED TO A MINIMUM OF 98 PERCENT STANDARD PROCTOR. MOISTURE
SHALL BE CONTROLLED TO WITHIN 3 PERCENT ABOVE OR BELOW OPTIMUM CONTENT.
4.10. MUD SLABS: PROVIDE 2" TO 4" THICK LEAN CONCRETE (2,000 PSI) "MUD-MAT" SLABS
WHERE FOUNDATION EXCAVATIONS WILL BE LEFT OPEN TO POTENTIAL RAINFALLS.
4.11. MODULUS OF SUBGRADE REACTION FOR SLABS ON GRADE: 100 PCI
4.12. FOUNDATION AND RETAINING WALL DESIGN PRESSURES:
ACTIVE PRESSURE 40 PSF/FT
AT REST PRESSURE 60 PSF/FT
PASSIVE PRESSURE 300 PSF/FT
FRICTION COEFFICIENT .30
4.13. FOUNDATION AND RETAINING WALLS SHALL HAVE A MINIMUM OF TWO FEET (2'-0")
OF FREE DRAINING GRANULAR FILL AGAINST THE BACK OF THE WALL OR SHALL HAVE
AN ACCEPTABLE COMMERCIAL GRADE OF DRAINAGE MAT PLACED AGAINST THE BACK OF
THE WALL.
4.14. FOUNDATION WALLS RETAINING EARTH SHALL BE BRACED AGAINST BACKFILL PRESSURES
UNTIL FLOOR SLABS AT TOP AND BOTTOM ARE IN PLACE. BACKFILLING IS STRICTLY
PROHIBITED UNTIL SLABS ARE IN PLACE.
4.15. FOUNDATION WALLS OR GRADE BEAMS HAVING EARTH PLACED ON EACH SIDE SHALL
HAVE BOTH FILLED SIMULTANEOUSLY TO MAINTAIN A COMMON ELEVATION.
5.0. CONCRETE:
5.1. CONCRETE SHALL HAVE 28-DAY COMPRESSIVE STRENGTHS AND DENSITIES AS FOLLOWS:
ELEMENT/MEMBER STRENGTH F'C DENSITY WC
SLABS ON GRADE 3 KSI 145 PCF
DRILLED PIERS (CAISSONS) 3 KSI 145 PCF
PIER CAPS & GRADE BEAMS 3 KSI 145 PCF
CAST-IN-PLACE WALLS 4 KSI 145 PCF
SLABS ON STEEL DECK 3 KSI 115 PCF
STAIR PAN FILL 3 KSI 115 PCF
EXTERIOR CONCRETE OR CONCRETE
EXPOSED TO WEATHER 4.5 KSI 145 PCF
PRECAST CONCRETE 5 KSI 145 PCF
ALL OTHER CONCRETE U.N.O. 4 KSI 145 PCF
6.6. DEVELOPMENT LENGTHS AND LAP SPLICES SHALL BE IN ACCORDANCE WITH
ACI 318 CHAPTER 12 AS INDICATED BELOW AND AS INDICATED ON THE DRAWINGS.
WHERE SPLICES ARE NOT CALLED OUT ON THE DRAWINGS, USE CLASS "B". THE BASIC
DEVELOPMENT LENGTH (LD) IS SHOWN AS A MULTIPLE OF THE BAR DIAMETER (DB) IN
THE TABLE BELOW. THE TENSION DEVELOPMENT LENGTHS SHALL BE MULTIPLIED
BY EACH OF THE APPLICABLE FACTORS IN PARAGRAPH "C" AS INDICATED FOR TENSION.
THE COMPRESSION DEVELOPMENT LENGTHS DO NOT REQUIRE ANY MODIFICATION. THE
COMPRESSION LAP SPLICE LENGTH IS NOTED IN PARAGRAPH "C". FINAL LENGTHS SHALL
BE ROUNDED UP TO THE NEAREST WHOLE INCH.
A. TWO TENSION DEVELOPMENT LENGTH CASES ARE NOTED IN THE TABLE BELOW. THESE
TWO CASES ADDRESS CONDITIONS OF MINIMUM BAR SPACING AND MINIMUM CLEAR
CONCRETE COVER. BOTH SPACING AND COVER MUST COMPLY IN SELECTING CASE 1 OF
THE TENSILE DEVELOPMENT LENGTH. WHERE THERE IS ANY QUESTION OF SPACING OR
COVER THE LARGER DEVELOPMENT LENGTH (CASE 2) SHALL BE USED.
CASE 1: BAR SPACING GREATER THAN 2DB AND CLEAR COVER GREATER THAN DB
CASE 2: BAR SPACING EQUAL/LESS THAN 2DB OR CLEAR COVER EQUAL/LESS THAN DB
B. DEVELOPMENT LENGTHS (LD) FOR REINFORCING FY = 60 KSI:
F'C COMPRESSION TENSION
PSI ALL CASES CASE 1 CASE 2
3000 22 DB 55 DB 82 DB
4000 19 DB 48 DB 72 DB
5000 18 DB 43 DB 64 DB
C. DEVELOPMENT LENGTH MODIFIERS: MULTIPLICATION FACTORS APPLY TO
THE BASIC "LD" INDICATED ABOVE AND ARE CUMULATIVE OVER EACH OF THE
REQUIREMENTS NOTED BELOW.
I. COMPRESSION: CLASS "C" LAP SPLICE REQUIREMENT.......... 30 DB
II. TENSION: CLASS "A" LAP SPLICE REQUIREMENT (EQUALS LD).... 1.0
III. TENSION: CLASS "B" LAP SPLICE REQUIREMENT................ 1.3
IV. TENSION: TOP BARS WITH > 12" OF CONCRETE BELOW........... 1.3
V. TENSION: BARS SMALLER THAN #7............................ 0.8
VI. TENSION: BARS IN LIGHTWEIGHT AGGREGATE CONCRETE.......... 1.3
VII. TENSION: EPOXY COATED BARS WITH CLEAR SPACING < 6 DB
OR SIDECOVER < 3 DB...................................... 1.5
VIII. TENSION: EPOXY COATED BARS OTHER THAN ABOVE.............. 1.2
6.7. A CLASS "B" SPLICE IS REQUIRED WHEREVER ALL REINFORCING BARS CROSSING
A SECTION ARE SPLICED.
6.8. REINFORCING BARS SHALL BE WELDED ONLY WHERE SHOWN ON THE STRUCTURAL
DRAWINGS AND WELDS SHALL BE IN ACCORDANCE WITH THE "STRUCTURAL WELDING
CODE - REINFORCING STEEL" (AWS D1.4). NO OTHER REINFORCING MAY BE WELDED
WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. TACK WELDING OF ANY
REINFORCING IS STRICTLY PROHIBITED.
6.9. WELDED WIRE MAT/FABRIC SHALL BE LAPPED 1'-0" AT ALL SPLICES.
6.10. ALL REINFORCING TERMINATING AT THE TOPS OF COLUMNS AND PILASTERS SHALL
BE HOOKED, U.N.O.
6.11. SUBMIT SHOP DRAWINGS FOR FABRICATION, BENDING, AND PLACEMENT OF CONCRETE
REINFORCEMENT. COMPLY WITH ACI DETAILING MANUAL (SP-66) SHOWING BAR
SCHEDULES, STIRRUP SPACING, DIAGRAMS OF BENT BARS, ARRANGEMENT OF CONCRETE
REINFORCEMENT. INCLUDE SPECIAL REINFORCEMENT REQUIRED AT OPENINGS THROUGH
CONCRETE STRUCTURES. INCLUDE ALL ACCESSORIES SPECIFIED/REQUIRED TO
SUPPORT REINFORCING.
6.12. SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMISSION
AND SHALL BEAR THE CONTRACTOR'S APPROVAL STAMP ACCEPTING RESPONSIBILITY
FOR DIMENSIONS, QUANTITIES AND COORDINATION WITH THE OTHER TRADES.
6.13. SUBMIT THREE (3) 24" X 36" PRINTS OF EACH SHOP DRAWING FOR REVIEW. SEE
PROJECT SPECIFICATIONS FOR SPECIFIC REQUIREMENTS.
6.14. ALTERNATIVELY, WHERE ACCEPTABLE TO ARCHITECT, DRAWINGS MAY BE ELECTRONICALLY
SUBMITTED, PROVIDED LEGIBILITY IS MAINTAINED. REVIEW COMMENTS ONLY WILL
BE ELECTRONICALLY FORWARDED TO THE CONTRACTOR.
6.15. CONTRACTOR SHALL PROVIDE IN HIS SCHEDULE FOR A SHOP DRAWING REVIEW AND
RETURN TIME OF A MINIMUM OF FIFTEEN (15) WORKING DAYS IN THE STRUCTURAL
ENGINEER'S OFFICE.
6.16. CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER A MINIMUM OF 48 HOURS
PRIOR TO ALL CONCRETE POURS IN ORDER TO PERMIT REINFORCING STEEL REVIEW
IF REQUIRED BY THE STRUCTURAL ENGINEER.
7.0 STRUCTURAL PRECAST CONCRETE:
7.1. PRECAST CONCRETE CONSTRUCTION SHALL CONSIST OF THE DESIGN, MANUFACTURE,
TRANSPORTATION, AND ERECTION OF COLUMNS, BEAMS, HOLLOW CORE PLANK, DOUBLE TEES,
WALL PANELS, SHEAR WALLS, AND STAIR SLABS.
7.2. DESIGN OF PRECAST CONCRETE ELEMENTS AND ALL CONNECTIONS FOR SUCH ELEMENTS SHALL BE
ENTIRELY THE RESPONSIBILITY OF THE PRECAST SUPPLIER/MANUFACTURER AND SHALL BE IN
ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS OF THE AMERICAN CONCRETE
INSTITUTE (ACI), THE PRESTRESSED CONCRETE INSTITUTE (PCI), THE INTERNATIONAL
STATE BUILDING CODE, AND THE PROJECT SPECIFICATIONS AND GENERAL NOTES. DEVIATION
FROM THE STANDARDS OR REQUIREMENTS CONTAINED THEREIN SHALL BE APPROVED IN WRITING
BY THE STRUCTURAL ENGINEER PRIOR TO PROCEEDING.
7.3. PRECAST CONCRETE MEMBERS SHALL HAVE THE FOLLOWING MINIMUM FIRE RESISTANCE:
A. COLUMNS 2 HOURS
B. BEAMS 1 1/2 HOURS
C. HOLLOW CORE PLANK 1 1/2 HOURS
7.4. PRECAST MEMBERS MAY BE CONVENTIONALLY REINFORCED AND/OR PRESTRESSED. THE DESIGN
SHALL BE CONSISTENT WITH THE LOAD, SPAN, MEMBER GEOMETRY, HANDLING STRESS, ETC..
DESIGN LOADS ARE SHOWN ON THE DRAWINGS.
7.5. PRECAST CONTRACTOR SHALL FURNISH COMPLETE DESIGN CALCULATIONS, INCLUDING DETAILS
OF CONNECTIONS, BEARINGS, FITTINGS, AND ANTICIPATED CAMBERS.
7.6. PRECAST CONTRACTOR SHALL FURNISH AND PLACE ANY TEMPORARY SHORING, BRACING, ETC., REQUIRED FOR ERECTION OF THE PRECAST WORK.
7.7. PRECAST CONTRACTOR SHALL FURNISH ALL PLATES, INSERTS, ANGLES, RODS, ETC., REQUIRED TO CONNECT PRECAST TO PRECAST OR CAST-IN-PLACE CONCRETE, STEEL, MASONRY, OR OTHER
SUPPORTING STRUCTURE.
7.8. PRECAST CONTRACTOR SHALL CAST INTO THE PRECAST MEMBERS ALL STRUCTURAL INSERTS, BOLTS, PLATES, ANGLES, DOWELS, KEYWAYS, OR OTHER ITEMS AS SHOWN ON THE CONTRACT
DRAWINGS.
7.9. ERECTION OF PRECAST MEMBERS SHALL INCLUDE THE FURNISHING AND PLACING OF MILD STEEL REINFORCING AND WET CAST OR DRY PACKED CONCRETE AT CLOSURES OR CONNECTIONS OUTSIDE
THE PRECAST ELEMENT.
7.10. DEVIATIONS FROM THE CONTRACT DOCUMENTS TO ACCOMMODATE MANUFACTURING, SHOP, OR
ERECTION PRACTICES WILL BE CONSIDERED. DEVIATIONS WILL BE PERMITTED ONLY AFTER
THE COR'S APPROVAL OF THE CONTRACTOR'S PROPOSED DEVIATION IS SUBMITTED FOR
REVIEW WITH COMPLETE CALCULATIONS AND/OR DETAIL DRAWINGS.
7.11. PRECAST DOUBLE TEES AND HOLLOW CORE PLANK:
A. TEES/PLANK SHALL BE DESIGNED TO SUPPORT THE LOADS SHOWN ON THE DRAWINGS, PLUS
ADDITIONAL CONCENTRATIONS AS REQUIRED BY THE GOVERNING BUILDING CODE OR
AS SHOWN ON RELATED CONTRACT DOCUMENTS.
B. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS
FOR OPENINGS THROUGH PLANK NOT SHOWN ON THE STRUCTURAL DRAWINGS.
PRECAST CONTRACTOR SHALL LAY OUT TEES/PLANK CONSIDERING REQUIRED OPENINGS AND
SHALL FURNISH HEADERS OR OTHER SUPPORTS AS REQUIRED.
C. LOCATIONS OF FIELD CUT OPENINGS SHALL BE COORDINATED WITH THE TEES/PLANK
LAYOUT.
D. PRECAST CONTRACTOR SHALL GROUT ALL JOINTS BETWEEN TEES/PLANKS. SEE PROJECT
SPECIFICATIONS FOR REQUIREMENTS.
E. MAXIMUM IN PLACE GROUTED PLANK WEIGHTS EXCLUDING TOPPING SHALL NOT
EXCEED FOR:
I. 6" PLANK 49 PSF (UNTOPPED)
II. 8" PLANK 46 PSF (UNTOPPED)
II. 10" PLANK 68 PSF (UNTOPPED)
F. MAXIMUM WEIGHTS OF DOUBLE TEES SHALL NOT EXCEED 74 PSF.
7.12. PRECAST WALL PANELS SHALL BEAR ON FOUNDATIONS AND SHALL BE DESIGNED TO SUPPORT
ALL DEAD, LIVE, WIND, SEISMIC, AND LATERAL EARTH PRESSURE LOADS ON THE PANEL
IDENTIFIED IN THE GENERAL NOTES OR ELSEWHERE ON THE DRAWINGS. REFER TO
ARCHITECTURAL DRAWINGS FOR WALL CONSTRUCTION ABOVE.
5.2. CONCRETE MIX DESIGNS:
A. SUBMITTALS: SUBMIT WRITTEN REPORTS OF EACH PROPOSED CONCRETE MIX NOT
LESS THAN 15 DAYS PRIOR TO THE START OF WORK. DESIGN MIXES PREPARED
MORE THAN TWELVE (12) MONTHS PRIOR TO THE DATE OF THE SUBMITTAL ARE
NOT PERMITTED.
B. MIX DESIGNS, INCLUDING W/C RATIOS AND SLUMPS, SHALL BE PREPARED IN
ACCORDANCE WITH THE MOST CURRENT ACI 301 CHAPTER 4, EXCEPT WHERE
NOTED OTHERWISE IN THE PROJECT SPECIFICATIONS. CEMENT SHALL CONFORM TO
ASTM C 150 TYPE I OR AT CONTRACTOR'S OPTION, ASTM C 595 TYPE IP WHERE
FLY ASH IS PERMITTED IN ACCORDANCE WITH THE SPECIFICATIONS. NORMAL
WEIGHT AGGREGATE SHALL CONFORM TO ASTM C 33 AND LIGHT WEIGHT AGGREGATE
SHALL CONFORM TO ASTM C 330. NO ADMIXTURES CONTAINING CALCIUM CHLORIDE
SHALL BE PERMITTED IN ANY CONCRETE.
C. AGGREGATE SIZES SHALL BE:
FORMED CONCRETE ELEMENTS, U.N.O. #67 STONE (3/4" MAX.)
GRADE SLABS AND EARTH FORMED ELEMENTS #57 STONE (1" MAX.)
COARSE MASONRY GROUT PER SECTION 042900 #8 STONE (3/8" MAX.)
FINE MASONRY GROUT PER SECTION 042900 #4 STONE (3/16" MAX.)
D. WATER REDUCING ADMIXTURE SHALL BE USED IN ALL CONCRETE.
E. AIR ENTRAINING ADMIXTURE IN ACCORDANCE WITH ACI 301 TABLE 4.4.1.
SHALL BE USED IN ALL CONCRETE EXPOSED TO FREEZING AND THAWING DURING
CONSTRUCTION OR SERVICE CONDITIONS.
F. WATER/CEMENT RATIO SHALL NOT EXCEED 0.45 FOR ANY CONCRETE SUBJECTED TO
FREEZING/THAWING.
G. ALL PUMPED CONCRETE SHALL HAVE A WATER/CEMENT RATIO LESS THAN 0.50 AND
SHALL CONTAIN A HIGH RANGE WATER REDUCING ADMIXTURE (SUPERPLASTICIZER).
H. IN NO CASE SHALL A WATER/CEMENT RATIOS EXCEED THE FOLLOWING:
F'C 3000 PSI 0.60 MAX. W/C RATIO
F'C 4000 PSI 0.50 MAX. W/C RATIO
F'C 5000 PSI 0.42 MAX. W/C RATIO
5.3. CURING:
A. LIQUID MEMBRANE CURING COMPOUND WITH A MINIMUM 30% SOLIDS CONTENT SHALL
BE APPLIED WITHIN TWO (2) HOURS AFTER COMPLETION OF FINISHING TO ALL
CONCRETE FLATWORK AND WALLS, U.N.O., OTHER THAN FOOTINGS AND GRADE BEAMS.
B. FLOORS IN AREAS RECEIVING QUARRY TILE, CERAMIC TILE AND LIQUID FLOOR
HARDENER SHALL BE CURED WITH SPECIFIED DISSIPATING LIQUID MEMBRANE
CURING COMPOUND OR WET CURED BY USE OF MOISTURE RETAINING COVER.
DISSIPATING CURING COMPOUND SHALL BE THOROUGHLY BROOMED AND WASHED
OFF PRIOR TO APPLICATION OF FLOOR FINISH.
5.4. WHEN COLD WEATHER CONDITIONS EXIST, PLACE AND CURE CONCRETE IN ACCORDANCE
WITH ACI 306 "COLD WEATHER CONCRETING". WHERE USE IS DESIRED, SUBMIT FOR
ENGINEER'S APPROVAL A NON-CORROSIVE, NON-CHLORIDE, ACCELERATING ADMIXTURE
FOR CONCRETE EXPOSED TO TEMPERATURES BELOW 40 DEGREES. UNIFORMLY HEAT WATER
AND AGGREGATES TO A TEMPERATURE OF NOT LESS THAN 50 DEGREES.
5.5. WHEN HOT WEATHER CONDITIONS EXIST, PLACE AND CURE CONCRETE IN ACCORDANCE
WITH ACI 305 "HOT WEATHER CONCRETING". COOL MATERIALS BEFORE MIXING TO
MAINTAIN CONCRETE PLACEMENT TEMPERATURE BELOW 90 DEGREES.
5.6. ALL CONSTRUCTION JOINTS SHOWN ON THE DRAWINGS SHALL BE INCORPORATED INTO
THE STRUCTURE UNLESS THE STRUCTURAL ENGINEER APPROVES THEIR ELIMINATION.
5.7. ADDITIONAL CONSTRUCTION JOINTS, REQUIRED TO FACILITATE CONSTRUCTION, ARE
SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER AND MAY REQUIRE
ADDITIONAL REINFORCING. SUCH JOINTS SHALL BE CLEARLY DETAILED ON THE SHOP
DRAWINGS AND ALL REINFORCING SHALL PASS CONTINUOUSLY THROUGH THE JOINT.
5.8. REINFORCING IN ALL ABUTTING CONCRETE, INCLUDING FOOTINGS, SHALL BE
CONTINUOUS THROUGH OR AROUND ALL CORNERS OR INTERSECTIONS. DOWELS OR
SPLICES SHALL BE EQUAL IN SIZE AND SPACING TO THE REINFORCING IN THE
ABUTTING MEMBERS.
5.9. REFER TO ARCHITECTURAL DRAWINGS FOR DOOR AND WINDOW OPENINGS, DRIPS,
REGLETS, WASHES, MASONRY ANCHORS, BRICK LEDGE ELEVATIONS, SLAB DEPRESSIONS
AND MISCELLANEOUS EMBEDDED PLATES, BOLTS, ANCHORS, ANGLES, ETC.
5.10. REFER TO ARCHITECTURAL DRAWINGS FOR CONCRETE FINISHES. WHERE FINISH IS
NOT SPECIFIED, CONFORM TO REQUIREMENTS OF ACI 301.
5.11. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR UNDERFLOOR,
PERIMETER AND OTHER DRAINS AND FOR SLEEVES, OUTLET BOXES, CONDUIT, ANCHORS,
ETC. THE VARIOUS TRADES ARE RESPONSIBLE FOR THEIR ITEMS.
5.12. BASE PLATES, ANCHOR BOLTS, SUPPORT ANGLES AND OTHER STEEL EXPOSED TO EARTH
OR GRANULAR FILL SHALL BE COVERED WITH A MINIMUM OF 3" OF CONCRETE.
5.13. FILL SLABS, NOT SHOWN ON THE STRUCTURAL DRAWINGS, SHALL BE REINFORCED WITH
A MINIMUM OF 6X6-W1.4XW1.4 WWM UNLESS NOTED OTHERWISE ON OTHER DRAWINGS
OR IN THE SPECIFICATIONS.
5.14. SLABS ON STEEL DECK SHALL BE PLACED SO THE FINISH SURFACE IS SCREEDED TO
WITHIN 1/4" OF THE TOP OF SLAB (T/SL) ELEVATION SHOWN ON THE DRAWINGS.
SCREED SUPPORTS SHALL BE PLACED OVER OR IMMEDIATELY ADJACENT TO BEAM OR
GIRDER LINES - SCREED SUPPORTS SHALL NOT BE LOCATED ON DECK SPANNING
BETWEEN BEAMS OR GIRDERS.
5.15. FINISHING TOLERANCE SHALL BE WITHIN CLASS B IN ACCORDANCE WITH ACI 301
AND CONSIDERATION SHALL BE GIVEN TO SEQUENCING OF CONCRETE PLACEMENT TO
FACILITATE CONTROL OF FINISH ELEVATIONS.
5.16. NON-SHRINK GROUT SHALL BE PRE-MIXED, NON-CORROSIVE, NON-METALLIC,
NON-STAINING CONTAINING SILICA SANDS, PORTLAND CEMENT, SHRINKAGE
COMPENSATING AND WATER REDUCING AGENTS. PRODUCT SHALL ONLY REQUIRE THE
ADDITION OF WATER. MINIMUM COMPRESSIVE STRENGTH SHALL BE 2500 PSI AFTER
ONE DAY AND 7000 PSI AFTER 28 DAYS. GROUT SHALL BE FREE OF GAS PRODUCING
OR AIR RELEASING AND OXIDIZING AGENTS AND CONTAIN NO CORROSIVE IRON,
ALUMINUM OR GYPSUM.
5.17. PROVIDE CONCRETE GROUT - NOT MORTAR - FOR REINFORCED MASONRY LINTEL AND
BOND BEAMS WHERE INDICATED ON DRAWINGS OR AS SCHEDULED.
5.18. TOLERANCE FOR ANCHOR BOLTS AND OTHER EMBEDDED ITEMS SHALL BE PER THE
AISC CODE OF STANDARD PRACTICE SECTION 7.5.
5.19. UNLESS OTHERWISE SHOWN IN THE ARCHITECTURAL DRAWINGS, PROVIDE 3/4" CHAMFERS
AT ALL COLUMN, WALL, SLAB OR BEAM EDGES THAT ARE EXPOSED TO VIEW IN THE
FINISHED STRUCTURE.
6.0. REINFORCING STEEL:
6.1. REINFORCING SHALL BE DOMESTIC NEW BILLET STEEL CONFORMING TO ASTM A615,
GRADE 60 OR 60S INCLUDING STIRRUPS AND TIES, EXCEPT THAT REINFORCING WHICH
IS REQUIRED TO BE WELDED SHALL CONFORM TO ASTM A706.
6.2. FIELD BENDING OF CONCRETE REINFORCING STEEL IS NOT PERMITTED WITHOUT
WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER.
6.3. WELDED WIRE REINFORCING SHALL CONFORM TO ASTM A1064.
6.4. ALL REINFORCING SHALL BE DETAILED, FABRICATED AND PLACED IN ACCORDANCE
WITH ACI SP-66 "ACI DETAILING MANUAL - 2004" AND THE "CRSI MANUAL OF
STANDARD PRACTICE", LATEST EDITION.
6.5. MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE U.N.O.:
A. UNFORMED SURFACE CAST AGAINST EARTH........................ 3 IN.
B. FORMED SURFACE EXPOSED TO EARTH/WEATHER.................... 2 IN.
C. FORMED SLABS AND WALLS NOT EXPOSED TO
EARTH/WEATHER FOR #11 AND SMALLER BAR.................... 3/4 IN.
D. ALL OTHER FORMED ELEMENTS NOT EXPOSED
TO EARTH/WEATHER....................................... 1-1/2 IN.
7.12. PRECAST WALL PANELS SHALL BEAR ON FOUNDATIONS AND SHALL BE DESIGNED TO SUPPORT
ALL DEAD, LIVE, WIND, SEISMIC, AND LATERAL EARTH PRESSURE LOADS ON THE PANEL
IDENTIFIED IN THE GENERAL NOTES OR ELSEWHERE ON THE DRAWINGS. REFER TO
ARCHITECTURAL DRAWINGS FOR WALL CONSTRUCTION ABOVE.
7.13. PRECAST SHEAR WALLS SHALL BE DESIGNED TO RESIST THE SHEARS INDICATED ON THE
DRAWINGS. THE SHEAR SHALL BE CONSIDERED APPLIED FROM THE LEVEL ABOVE TO THE TOP
OF THE WALL.
7.14. SEE PRECAST COLUMN AND BEAM SCHEDULES FOR ADDITIONAL NOTES.
7.15. PRECAST CONTRACTOR SHALL MAKE PROVISIONS FOR ANCHORAGE REQUIREMENTS OF ALL
CLADDING AND PROVIDE NECESSARY HARDWARE REQUIRED TO BE CAST INTO ALL PRECAST
ELEMENTS. REFER AND COORDINATE WITH ARCHITECTURAL DRAWINGS AND CLADDING DETAILS.
8.0. STRUCTURAL MASONRY:
8.1. ALL STRUCTURAL MASONRY SHALL CONFORM TO MOST CURRENT ACI 530 STANDARDS AS
APPROPRIATE TO THE MATERIAL.
8.2. MASONRY STRENGTH AND GRADE:
A. CONCRETE MASONRY UNITS (CMU):
I. UNITS SHALL BE LIGHTWEIGHT CELLULAR UNITS CONFORMING TO ASTM C 90,
GRADE N-2. CONCRETE MASONRY NET AREA UNIT STRENGTH SHALL BE NO LESS
THAN 1900 PSI IN ACCORDANCE WITH ASTM C 140, WITH A UNIT WEIGHT NOT
EXCEEDING 105 PCF. SEE SPECIFICATIONS.
II. DESIGN COMPRESSIVE STRENGTH OF CMU (F'M) = 1500 PSI.
8.3. SUBMITTALS: CONTRACTOR SHALL SUBMIT FOR APPROVAL TEST REPORTS ON MASONRY
UNITS SHOWING UNIT WEIGHT, COMPRESSIVE STRENGTH, ABSORPTION, VOLUME
CHANGE AND SHRINKAGE PER ASTM C90 NO LATER THAN 15 WORKING DAYS PRIOR TO
THE COMMENCEMENT OF MASONRY CONSTRUCTION.
8.4. MORTAR SHALL CONFORM TO ASTM C 270. MORTAR SHALL BE TYPE "S" AND SHALL
HAVE A 28-DAY COMPRESSIVE STRENGTH OF 1800 PSI.
8.5. MASONRY GROUT FILL SHALL CONFORM TO ASTM C 476. GROUT, EITHER FINE OR
COARSE AGGREGATE PER SPECIFICATIONS, SHALL HAVE A 28-DAY COMPRESSIVE
STRENGTH OF 3000 PSI. MASONRY CONCRETE FILL SHALL CONFORM TO THE
REQUIREMENTS NOTED UNDER "CONCRETE" IN THE GENERAL NOTES.
8.6. GROUTING:
A. ALL BOND BEAMS SHALL BE FILLED WITH GROUT AND REINFORCED AS
INDICATED ON THE DRAWINGS (DETAILS OR SCHEDULES). MORTAR FILL IS
NOT PERMITTED.
B. ALL MASONRY WALL CELLS OR CAVITIES INDICATED AS REINFORCED SHALL BE
GROUTED FOR THE FULL HEIGHT OF THE WALL, UNLESS SPECIFICALLY NOTED
OTHERWISE ON THE DRAWINGS. UN-REINFORCED WALLS INDICATED AS GROUTED
SHALL BE GROUTED FULL HEIGHT, UNLESS SPECIFICALLY NOTED OTHERWISE.
MORTAR FILL IS NOT PERMITTED.
C. ALL MASONRY CELLS OR CAVITIES BELOW GRADE SHALL BE GROUTED SOLID
UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. MORTAR FILL IS
NOT PERMITTED.
D. VERTICAL GROUTING SHALL BE LOW LIFT OR HIGH LIFT AS FOLLOWS:
I. LOW LIFT GROUTING SHALL BE USED FOR ALL CAVITY WALLS AND MAY BE
USED FOR ALL WALLS AT THE OPTION OF THE CONTRACTOR. LIFTS SHALL
NOT EXCEED 4'-0" IN HEIGHT.
II. HIGH LIFT GROUTING IS PERMISSIBLE ONLY FOR FILLING OF CELLULAR
MASONRY UNITS AND SHALL NOT EXCEED ONE STORY IN HEIGHT. CLEAN
OUT HOLES SHALL BE PROVIDED AT THE BASE OF EACH GROUTED CELL.
E. GROUTING SHALL BE STOPPED 1-1/2" BELOW THE TOP OF A COURSE TO FORM A
KEY AT THE JOINT.
F. GROUTING OF MASONRY BEAMS OR LINTELS SHALL BE DONE IN ONE CONTINUOUS
OPERATION.
8.7. REINFORCING:
A. ALL BARS MARKED "CONTINUOUS" SHALL BE LAPPED PER "CMU MASONRY LAP SPLICE
SCHEDULE" SHOWN ON THE STRUCTURAL DRAWINGS AND MUST COMPLY WITH THE
MOST CURRENT EDITION OF THE APPLICABLE BUILDING CODE.
B. FOUNDATION DOWELS MAY SLOPE A MAXIMUM OF 1:6 TO ALIGN WITH WALL
CAVITIES OR VERTICAL CMU CORES. GREATER SLOPES WILL REQUIRE
REPLACEMENT OF THE FOUNDATION DOWELS.
C. SPLICED REINFORCING SHALL BE LAPPED UNDER "REINFORCING" ABOVE OR AS
SHOWN ON DRAWINGS, WHICHEVER IS GREATEST. ALL SPLICES SHALL BE WIRED
TOGETHER OR HELD IN PLACE WITH BAR POSITIONERS.
D. VERTICAL REINFORCING BARS SHALL HAVE A MINIMUM CLEARANCE OF 3/4"
FROM MASONRY AND SHALL BE HELD IN POSITION TOP AND BOTTOM AND AT
INTERVALS NOT EXCEEDING 4'-0". ACCESSORIES FOR SUCH SUPPORT SHALL
BE USED. PROVIDE "AA WIRE PRODUCTS COMPANY" (OR APPROVED EQUAL) REBAR
POSITIONER AA225 OR AA239 FOR VERTICAL BARS AND AA238 FOR HORIZONTAL
BARS OR APPROVED EQUAL PRODUCTS FROM OTHER SUPPLIERS.
E. HORIZONTAL JOINT REINFORCING SHALL BE LAPPED NO LESS THAN 6" ALL
SPLICES, INCLUDING CORNERS AND TEES WHERE NO CONTROL JOINT IS USED.
F. ALL HORIZONTAL JOINT REINFORCING SHALL STOP AT CONTROL JOINTS.
G. HORIZONTAL REINFORCING IN BOND BEAMS SHALL BE CONTINUOUS THROUGH
CONTROL JOINTS.
8.8. MASONRY SHOWN ON THE STRUCTURAL DRAWINGS DEFINES THE STRUCTURAL EXTENTS
AND REQUIREMENTS FOR MASONRY FOR SUPPORTING MEMBERS, FLOORS, ROOFS OR
WALLS AND SHALL BE BUILT IN CONFORMANCE WITH THE REQUIREMENTS OF THESE
DRAWINGS AND NOTE 1 ABOVE. REFER TO THE ARCHITECTURAL DRAWINGS FOR
THE TOTAL SCOPE OF THE MASONRY AND FOR LOCATIONS AND DETAILS OF OPENINGS,
SPECIAL COURSING OR OTHER MASONRY DETAILS.
8.9. MASONRY CONTRACTOR SHALL PROVIDE FOR AND COORDINATE WITH OTHER TRADES
FOR PLACEMENT OF ALL ITEMS TO BE EMBEDDED OR BUILT INTO THE MASONRY.
8.10. ELECTRICAL CONDUIT, OR EQUIPMENT FROM OTHER TRADES, SHALL NOT OCCUR IN
GROUTED AND REINFORCED CELLS. WHERE CONFLICTS OCCUR THE CONTRACTOR SHALL
NOTIFY THE ENGINEER FOR DIRECTION PRIOR TO PROCEEDING.
9.0. INSPECTION AND TESTING:
9.1. AN INDEPENDENT TESTING LABORATORY SHALL BE RETAINED IN ACCORDANCE WITH
THE PROJECT SPECIFICATIONS TO PERFORM TESTING OF FOUNDATION BEARING
STRATA, ENGINEERED FILLS, CONCRETE, GROUT, STEEL, AND WELDING. SEE
PROJECT SPECIFICATIONS FOR REQUIREMENTS.
9.2. THE CONTRACTOR, IN CONJUNCTION WITH THE TESTING LABORATORY AND IN
ACCORDANCE WITH THE PROJECT SPECIFICATIONS, SHALL DETERMINE THE FREQUENCY
OF THE TESTING NECESSARY TO INSURE THAT THE DESIGN REQUIREMENTS ARE
BEING MET.
9.3. THE TESTING AGENCY SHALL VERIFY THAT ALL WELDERS HAVE SATISFACTORILY
PASSED AWS QUALIFICATION TESTS FOR THE WELDS WHICH THEY WILL PERFORM.
9.4. THE CONTRACTOR AND TESTING AGENCY SHALL REQUIRE THAT AWS QUALIFICATION
TESTS FOR WELDING OF MATERIAL LESS THAN 1/8" IN THICKNESS ARE PASSED
BY WELDERS EXPECTED TO ERECT LIGHTGAGE FRAMING MATERIALS. THESE
TESTS ARE NOT THE SAME AS FOR MATERIALS 1/8" OR GREATER IN THICKNESS (I.E.
STRUCTURAL STEEL MATERIALS)
9.5. ALL WELDING SHALL BE INSPECTED AND TESTED IN ACCORDANCE WITH AWS D1.1 OR
D1.3 AS APPROPRIATE TO THE MATERIAL THICKNESS.
9.6. THE TESTING AGENCY SHALL VERIFY THAT THE METAL DECK IS ATTACHED TO THE
STRUCTURAL STEEL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND
APPROVED SHOP DRAWINGS.
9.7. CONCRETE TESTING SHALL BE IN ACCORDANCE WITH ACI 301 CHAPTER 16 AND
APPROPRIATE AND WITH THE PROJECT SPECIFICATIONS.
No. Description Date th re e i n c h e s o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t 1 2 3 4 5
Drawing Title:Seal:
ARCHITECT / ENGINEERS:
Project Title:
Date:
Project Number:
Drawing Number:
Drawn:Checked:
Building Number:
D C
B A
Revisions:
8016 TOWER POINT DRIVE
CHARLOTTE, NC 28227
P 704.814.1320 F 704.321.0833
Project Phase:
D C
B A
1 2 3 4 5 6
Location:
CONSULTANTS:
Office of
Construction and Facilities
Management
LRSPC #16910
C:\Users\jlorch\Documents\16910 VAMC Clarksburg Parking Deck-Structural_jlorch.rvt
HDG PROJECT: 16013 S002
STRUCTURAL GENERAL NOTES
CONSTRUCTION DOCUMENTS 100%
CONSTRUCT PARKING
STRUCTURE
MAY 14, 2018 RJMMSR
LOUIS A. JOHNSON VAMC
540-320
1.1
10.0. CONSTRUCTION AND SAFETY:
10.1. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL SAFETY REGULATIONS, PROGRAMS
AND PRECAUTIONS RELATED TO ALL WORK ON THIS PROJECT.
10.2. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PROTECTION OF PERSONS AND
PROPERTY EITHER ON OR ADJACENT TO THE PROJECT AND SHALL PROTECT SAME
AGAINST INJURY, DAMAGE OR LOSS.
10.3. MEANS AND METHODS OF CONSTRUCTION AND ERECTION OF STRUCTURAL MATERIALS ARE
SOLELY THE CONTRACTOR'S RESPONSIBILITY.
10.4. STRUCTURAL DRAWINGS ARE INTENDED TO BE USED IN CONJUNCTION WITH THE
DRAWINGS OF OTHER CONSULTANTS AND TRADES. THE CONTRACTOR SHALL COORDINATE
THE VARIOUS REQUIREMENTS.
10.5. NO OPENINGS NOR ANY CHANGES IN SIZE, DIMENSION OR LOCATION SHALL BE MADE
IN ANY STRUCTURAL ELEMENTS WITHOUT WRITTEN APPROVAL OF THE COR.
10.6. OPENINGS 1'-0" OR LESS ON A SIDE ARE GENERALLY NOT SHOWN ON THE STRUCTURAL
DRAWINGS. REFER TO DRAWINGS OF OTHER CONSULTANTS FOR SUCH OPENINGS.
10.7. FIREPROOFING OF STRUCTURAL ELEMENTS IS NOT SHOWN ON THE STRUCTURAL
DRAWINGS. REFER TO THE SPECIFICATIONS AND ARCHITECTURAL DRAWINGS FOR FIRE
RATING REQUIREMENTS, MATERIALS AND METHODS.
10.8. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD
IMPOSED ON THE STRUCTURE. SUCH LOADS SHALL NOT EXCEED THE CAPACITY OF THE
STRUCTURE AT ANY TIME.
10.9. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION, AND ANY
TEMPORARY BRACING OR SUPPORT REQUIRED TO ACCOMMODATE THE CONTRACTOR'S
MEANS AND METHODS ARE THE RESPONSIBILITY OF THE CONTRACTOR.
10.10. THE CONTRACTOR SHALL INFORM THE COR, CLEARLY AND
EXPLICITLY IN WRITING, OF ANY DEVIATION OR SUBSTITUTION OF REQUIREMENTS
OF THE CONTRACT DOCUMENTS. CONTRACTOR IS NOT RELIEVED OF ANY REQUIREMENTS
OF THE CONTRACT DOCUMENTS BY VIRTUE OF THE COR'S REVIEW
OF SHOP DRAWINGS, PRODUCT DATA, ETC., UNLESS THE CONTRACTOR HAS CLEARLY
AND EXPLICITLY INFORMED THE COR IN WRITING OF ANY
DEVIATIONS OR SUBSTITUTIONS AT TIME OF SUBMISSION, AND THE STRUCTURAL
ENGINEER HAS GIVEN WRITTEN APPROVAL FOR THE SPECIFIC DEVIATIONS OR
SUBSTITUTIONS.
10.11. ALL THINGS WHICH, IN THE OPINION OF THE CONTRACTOR, APPEAR TO BE
DEFICIENCIES, OMISSIONS, CONTRADICTIONS OR AMBIGUITIES IN THE DRAWINGS OR
SPECIFICATIONS, SHALL BE BROUGHT TO THE ATTENTION OF THE COR.
CORRECTIONS OR WRITTEN INTERPRETATIONS SHALL BE ISSUED BEFORE
AFFECTED WORK MAY PROCEED.
10.12. IF THE CONTRACTOR CANNOT CONSTRUCT ANY PORTION OF THE WORK IDENTIFIED IN
THE DRAWINGS IN ACCORDANCE WITH THESE DRAWINGS AND SPECIFICATIONS, THEN
THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE COR PRIOR
TO PROCEEDING WITH THE WORK. WORK THAT DOES NOT COMPLY WITH THE DRAWINGS
MAY REQUIRE REMOVAL, TESTING, OR ENGINEERING EVALUATION AT THE
CONTRACTOR'S EXPENSE.
10.13. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO ORDERING
MATERIALS OR PROCEEDING WITH NEW WORK IN AREAS AFFECTED BY EXISTING
CONDITIONS. COR SHALL BE INFORMED IN WRITING OF
CONFLICTS BETWEEN EXISTING AND PROPOSED NEW CONSTRUCTION.
10.14 CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL DIMENSIONS SHOWN ON THE
CONTRACT DOCUMENTS. INCONSISTENCIES ON THE STRUCTURAL DRAWINGS OR
BETWEEN THE STRUCTURAL DRAWINGS AND ANY OTHER CONTRACT, SHOP, FABRICATION,
OR OTHER DRAWINGS OR INFORMATION SHALL BE BROUGHT TO THE ATTENTION OF THE
COR PRIOR TO PROCEEDING WITH AFFECTED WORK.
10.15. DO NOT SCALE THESE DRAWINGS, USE THE DIMENSIONS SHOWN.
10.16. CONTRACTOR SHALL PROVIDE IN HIS SCHEDULE FOR A SHOP DRAWING REVIEW AND
RETURN TIME OF A MINIMUM OF FIFTEEN (15) WORKING DAYS IN THE STRUCTURAL
ENGINEER'S OFFICE.
10.17. VERIFY ELEVATOR PIT DIMENSIONS, LOCATIONS, LOADS AND DETAILS WITH THE
ELEVATOR SUPPLIER PRIOR TO THE FABRICATION AND/OR INSTALLATION OF
ANY MATERIAL.
11.0 STRUCTURAL ABBREVIATIONS:
ABBREV. DEFINITION ABBREV. DEFINITION
A.B. ANCHOR BOLTS HOF HORIZONTAL OUTER FAC
ABV ABOVE HK HOOK
ADDNL ADDITIONAL HORZ HORIZONTAL
AFF ABOVE FINISHED FLOOR IF INNER FACE
ALT ALTERNATE INT INTERIOR
ARCH ARCHITECTURAL JT JOINT
B, BOT BOTTOM K KIPS (1000 LBS)
B/XXX BOTTOM OF XXX L, LEN LENGTH
BAL. BALANCE LAT LATERAL
BB BOND BEAM LBS POUNDS
BCX BOTTOM CHORD EXTENSION LE LEFT END
BL BRICK LEDGE LLH LONG LEG HORIZONTAL
BLDG BUILDING LLO LONG LEG OUTSTANDING
BLW BELOW LLV LONG LEG VERTICAL
BM BEAM LONG LONGITUDINAL
BRG BEARING MAS MASONRY
BRK BRICK MAX MAXIMUM
BTWN BETWEEN MECH MECHANICAL
CJ CONST., CONTROL JOINT MFR MANUFACTURER
CL,CLR CLEAR MIN MINIMUM
CMU CONC. MASONRY UNIT MTL METAL
COL COLUMN NOM NOMINAL
CONC CONCRETE OC, O/C ON CENTER
CONN CONNECTION OF OUTER FACE, OPP. FACE
CONST CONSTRUCTION OH OPPOSITE HAND
CONT CONTINUOUS OPP OPPOSITE
CTR CENTER OPNG OPENING
CTRD CENTERED PC PRECAST
DBA DEFORMED BAR ANCHOR PL PLATE
DET,DTL DETAIL RE RIGHT END
DIM DIMENSION REINFG REINFORCING
DK DECK REINF REINFORCEMENT
DWGS DRAWINGS REQD REQUIRED
DWL DOWEL RET RETAINING
EA EACH SOG SLAB ON GRADE
EE EACH END SC SLIP CRITICAL
EF EACH FACE SCHED SCHEDULE
EFF EFFECTIVE SECT SECTION
EJ EXPANSION JOINT S, SHRT SHORT
EL,ELEV ELEVATION SL SLAB
EOC EDGE OF CONCRETE SPA SPACING
EOD EDGE OF DECK STFNR STIFFENER
EOM EDGE OF MASONRY STL STEEL
EOS EDGE OF SLAB SUPPL SUPPLIER
ES EACH SIDE SUPT SUPPORT
EW EACH WAY T TOP
EXIST EXISTING T/XXX TOP OF XXX
EXP EXPANSION CX TOP CHORD EXTENSION
EXT EXTERIOR, EXTENSION THK THICK, THICKNESS
FK FOOT-KIPS TO THROUGHOUT
FL, FLR FLOOR TRAN TRANSVERSE
FOB FACE OF BRICK TYP TYPICAL
FOM FACE OF MASONRY UNO UNLESS NOTED OTHERWISE
FOS FACE OF STUD VERT VERTICAL
FP FULL PENETRATION VEF VERTICAL EACH FACE
FT FOOT, FEET VIF VERTICAL INNER FACE
FTG FOOTING VOF VERTICAL OUTER FACE
GB GRADE BEAM W WIDE, WIDTH
GEN GENERAL WF WELDED WIRE FABRIC
HEF HORIZONTAL EACH FACE WWM WELDED WIRE MAT
HIF HORIZONTAL INNER FACE XE EXTENDED END JOIST
STEP SPACING
4'-0" MIN.
2' -0
M
A X
'D
2" C
L.
'D'= FTG. THICKNESS
REINFORCING TO MATCH
BOTTOM FOOTING REINF.
#5@18" @
45 DEG. (TYP)
2"
2"
LENGTH
LAP
3"
STD
HOOK
36 DIA.
2'-0" MIN.
D
IA
2' -0
M
IN
HORIZ. REINF.
BEND OR LAP OUTSIDE BARS
OR PROVIDE CORNER BARS AS
SHOWN-LARGE BAR SIZE
GOVERNS LAP
@ CONTINUOUS FOOTING
36 DIA.
2'-0" MIN.
D
IA
2' -0
M
IN
@ FOOTING INTERSECTION
@ CONTINUOUS FOOTING
P
LA
N
"T
S E
E
BASE COURSE
NOTE: FOR INFORMATION ON VAPOR
BARRIER/RETARDER, REFER TO
ARCHITECTURAL DRAWINGS
AND SPECIFICATIONS
STOP REBAR @
EACH SIDE OF C.J.
1/2" DIA.x3'-0" SMOOTH
DOWEL @ 36" O.C.
GREASE ONE END. PLACE
@ MID-DEPTH OF SLABREBAR
C.J.
P
LA
N
"T
S E
E
BASE COURSE
NOTE: FOR INFORMATION ON VAPOR
BARRIER/RETARDER, REFER TO
ARCHITECTURAL DRAWINGS
AND SPECIFICATIONS
STOP REBAR @ EACH
SIDE OF C.J.
REBAR
PREFAB METAL
FORM 22 GA.
2xD
D S
E E
P
LA
N
#4@18" O.C.
8" 2'-0"
#4@18" O.C.
3'-0" 1'-4"
BASE COURSE
2xD
D M
A X
1/ 2"
S E
E P
LA
N
BASE COURSE
NOTE: FOR INFORMATION ON VAPOR
BARRIER/RETARDER, REFER TO
ARCHITECTURAL DRAWINGS
AND SPECIFICATIONS
REINF.
PER PLAN
NOTES
1"
S E
E P
LA
N
"T
4"
W.W.M. #3 @ 48" O.C.
CLIP ANGLE BY
STAIR SUPPLIER
STAIR STRINGER
SEE ARCH. DWGS.
CENTERLINE
ANCHOR BOLTS
BASE COURSE
2 #4 CONT.
NOTE: EXTEND THICKENED SLAB BETWEEN STAIR
STRINGERS AND 1'-0" BEYOND EACH.
2'-0"
T
KEY
1 1/2"
PROVIDE CONT. REGLET @ FACE & TOP
OF WALL WHERE EXPOSED TO VIEW,
COORDINATE LOCATION WITH ARCHITECT
PROVIDE BACKER ROD &
CAULK FILL PER ARCH. ONLY @
EXTERIOR BUILDING WALLS
WALL REINF.
NO REGLET REQ'D
WHERE NOT
EXPOSED TO VIEW
1/2"
3/4"
1/ 2"
T /3
T /3
T /3
@ CONCRETE WALLS
D
IA
2' -0
M
IN
HORIZ.
REINF.
ACI STD. HOOK
@ WALL INTERSECTION
@ WALL CORNERS
36 DIA.
2'-0" MIN.
D
IA
2' -0
M
IN
BEND OR LAP OUTSIDE BARS
OR PROVIDE CORNER BARS
AS SHOWN. LARGER BAR
SIZE GOVERNS LAP
HORIZ. REINF.
CORNER BARS:
MATCH SIZE & SPACE OF HORIZ.
BARS. WHERE SIZE AND SPACE
DIFFER, MATCH LARGER AREA.
PROVIDE #4@12" O.C. CORNER
BARS WHERE THERE ARE NO
HORIZ. BARS.
@ CONCRETE WALLS
PROVIDE CONT. REGLET @
FACE & TOP OF WALL.
SEE PLANS FOR LOCATIONS
OF CONTROL JOITNS PROVIDE BACKER ROD &
CAULK FILL PER ARCH.
ONLY @ EXTERIOR
BUILDING WALLS
NOTE:
PROVIDE WALL CONTROL JOINTS @ 25'-0" MAX;
FIRST JOINT @ 10'-0" FROM WALL CORNERS
1/2"
3/4"
WALL REINF.
CONT. VERTICAL KEY
WHERE CONSTRUCTION
JOINT OCCURS AT
CONTROL JOINT
SAME SIZE AND SPA.
AS HORIZ. BARS
80 DIA. LONG
@ CONCRETE WALLS EXPOSED TO VIEW
#4@12" E.W.
SEE ARCH. FOR
TREAD AND RISER
DIMENSIONS
#4 NOSING BAR
#4@12" DOWEL
TO ADJACENT
STRUCTURE
1'-6" 1'-6"
1'-6"
#4 DOWELS
BASE COURSE REQ'D
@ INTERIOR STAIRS ONLY
6"
1'- 6"
P
LA
N
"T
S E
E
BASE COURSE
NOTE: FOR INFORMATION ON VAPOR
BARRIER/RETARDER, REFER TO
ARCHITECTURAL DRAWINGS
AND SPECIFICATIONS
STOP REINF. @
EACH SIDE OF C.J.
REINF.
1/4" SAWCUT OR
STRIPPABLE CONTROL
JOINT AS REQ'D PER SPECS
T /4
M
IN
NOTE: PROVIDE
CONTROL JOINTS @
20'-0" O.C. MAXIMUM
6" 6"
BASE COURSE
#3@48"
SEE ARCH. DWGS. FOR WALL
THICKNESS AND LOCATION
#4@48" O.C.
PROVIDE DOWEL
WITH STD. HOOK
P
LA
N "T
S
E E
W A
LL
S
6" T
Y P
. 8
A T
1"
2 #4 CONT.
W.W.F.
NOTE:
THICKENED SLAB & #4 DOWELS
MUST ALSO BE INSTALLED WHERE
FUTURE NON-LOAD BEARING CMU WALLS
ARE TO BE INSTALLED REF. ARCH.
DWGS. FOR FUTURE WALL LOCATIONS
NOTE: FOR INFORMATION ON VAPOR
BARRIER/RETARDER, REFER TO
ARCHITECTURAL DRAWINGS
AND SPECIFICATIONS
REF. x-Sx.xx
FOR T/WALL BRACE &
TYP. WALL REINF. FOR
WALLS TALLER THAN 9'-4"
5" 1'
-6
GROUT WALL SOLID
@ REINFORCING
@ NON-LOAD BEARING MASONRY WALL PARTITIONS
PAST OPNG, HOOK REINF.
WHERE NOT POSSIBLE
TO MAINTAIN 36 DIA.
2-#5x4'-0" (WALLS)
1-#5X4'-0" (SLABS)
DIAGONAL BARS AT
EACH CORNER
ADD 1/2 OF PARALLEL
INTERRUPTED BARS AT
EACH SIDE OF OPNG.
BUT NOT LESS THAN
2-#5 (1 E.F.) IN WALL &
4-#5 (2T & 2B) IN SLABS
HOOK INTERUPTED
BARS (IN SLAB ONLY)
TYP.
36" DIA.
@ OPENINGS IN SLABS & WALLS
th re e i n c h e s o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t 1 2 3 4 5
Drawing Title:Seal:
ARCHITECT / ENGINEERS:
Project Title:
Date:
Project Number:
Drawing Number:
Drawn:Checked:
Building Number:
D C
B A
Revisions:
8016 TOWER POINT DRIVE
CHARLOTTE, NC 28227
P 704.814.1320 F 704.321.0833
Project Phase:
D C
B A
1 2 3 4 5 6
Location:
CONSULTANTS:
Office of
Construction and Facilities
Management
LRSPC #16910
C:\Users\jlorch\Documents\16910 VAMC Clarksburg Parking Deck-Structural_jlorch.rvt
HDG PROJECT: 16013 S003
STRUCTURAL TYPICAL DETAILS
CONSTRUCTION DOCUMENTS 100%
CONSTRUCT PARKING
STRUCTURE
MAY 14, 2018 JARMSR
LOUIS A. JOHNSON VAMC
540-320
1.1
3/4" = 1'-0"B1
TYP. STEPPED FOOTING
3/4" = 1'-0"B2
TYP. CORNER REINFORCING
3/4" = 1'-0"B3
TYP. CORNER REINFORCING
3/4" = 1'-0"
B5 TYP. CONSTRUCTION JOINT
3/4" = 1'-0"
B4 TYP. CONSTRUCTION JOINT
3/4" = 1'-0"
B6 TYP. SLAB DEPRESSION
3/4" = 1'-0"C1
TYP. THICKENED SLAB
3/4" = 1'-0"C2
TYP. WALL CONSTRUCTION
JOINT
3/4" = 1'-0"C4
TYP. CORNER REINFORCING
3/4" = 1'-0"C3
TYP. WALL CONTROL JT.
3/4" = 1'-0"C5
STAIR ON GRADE
3/4" = 1'-0"C6
TYP. CONSTRUCTION JOINT
3/4" = 1'-0"D1
TYP. THICKENED SLAB
3/4" = 1'-0"D2
TYPICAL REINFORCEMENT
2'- 0"
2'-0"
CONC. COLUMN
PER PLAN & SCHEDULE
1/2" PREFORMED JOINT
FILLER BOARD
BLOCKOUT
@ COLUMN
1'-0"
CMU BOND BM.
LA
P
S P
LI
C
E
LA
P
S P
LI
C
E
CORNER BAR
IN BOND BEAM
CMU
BOND BM.
REINFORCING
IN BOND BEAM
BENT BAR @ TEE
INTERSECTION
LAP SPLICES ARE TO BE PER "CMU
MANSORY LAP SPLICE SCHEDULE"
ON THIS SHEET.
@ MASONRY BOND BEAMS
WIDE FLANGE OR HSS
STEEL BEAM LINTEL
CMU BOND
BEAM LINTEL
C OPENINGL
LINTEL PER
SCHEDULE
2 TYP. WALL VERT. IN
FIRST VERT. CELLS AT
EA. SIDE OF OPENING
CONT. THRU CMU
BOND BM.
U.N.O.
8" BRG.
EXTEND TO NEXT
BOND BM./LINTEL/FTG.
AS OCCURS BELOW
3 TYP. WALL
VERT. AT EA. SIDE
OF OPENING
GROUT SOLID BELOW
LINTEL BEARING
EXTEND ABOVE TO
NEXT CONT. BOND BM.
OR OPENING IN WALL
@ EXTERIOR WALL
CMU
WALL CMU
WALL
PREFAB TEE
HORIZ. REINF.
PREFAB CORNER HORIZ.
JOINT REINFORCING
@ CORNER
@ INTERSECTION
@ JOINT REINFORCEMENT
CLEAR OPENING
0'-8" TO 3'-4"
3'-4" TO 4'-8"
4'-8" TO 6'-0"
6'-0" TO 8'-0"
8'-0" TO 10'-0"
10'-0" TO 12'-0"
REINFORCING
6" CMU 8" CMU 12" CMU
DEPTH
MIN.
BRG.
8" 1-#4 1-#4 2-#5 8"
8" 1-#4 1-#4 2-#5 8"
8" 1-#4 1-#4 2-#5 8"
16" 1-#4 1-#4 2-#5 8"
16" 1-#4 1-#4 2-#5 12"
16" - - 2-#5 12"
NOTE:
1. EXTEND REINFORCING TO END OF BEARING AT EACH SIDE OF OPENING.
2. FILL WITH GROUT ALL CORES UNDER BEARING FROM BOTTM OF LINTEL
TO 48" MINIMUM BELOW LINTEL.
3. LINTELS OVER 12'-0" CLEAR SPAN OR SUPPORTING FLOOR OR ROOF
REQUIRE SPECIAL DESIGN.
4. THIS SCHEDULE IS FOR LIGHTWEIGHT BLOCK ONLY (95PCF MAX.)
8" N
O M
N O
M
WIDTH
NOM.
WIDTH
NOM.
TYPICAL DETAILS
8" NOM. DEPTH 16" NOM. DEPTH
GROUT STD.
UNIT
8"
UNIT
CMU MASONRY LINTEL SCHEDULE
CMU MASONRY LAP SPLICE SCHEDULE
BAR SIZE
COVER LAP
#3
#4
#5
#6
#7
#8
3.625" 5.625"
8" 12" 8" 12"
27" 27"
3.563" 5.563" 36" 36"
3.500" 5.500" 45" 45"
3.438" 5.438" 54" 54"
3.375" 5.375" 63" 63"
3.313" 5.313" 91" 72"
NOTES:
1. SINGLE BAR PER CELL.
2. BAR LOCATED @ CENTER
OF CELL.
3. f'm= 1500 PSI
4. f'y= 60000 PSI
STEEL ANGLE LOOSE LINTEL SCHEDULE FOR MASONRY VENEER
0'-8" TO 3'-4"
ONE ANGLE FOR EA. 4"
WYTHE MASONRY VENEER
DETAILCLEAR OPENING
L 3 1/2"x 3 1/2"x 1/4" 4"
3'-4" TO 5'-4" L 4"x 3 1/2"x 1/4" LLV 6"
5'-4" TO 7'-4" L 5"x 3 1/2"x 5/16" LLV 8"
7'-4" TO 10'-0" L 6"x 3 1/2"x 5/16" LLV 8"
NOM. 4"
WYTHE
NOTES:
1. WHERE LINTELS BEAR ON HOLLOW MASONRY UNITS FILL ALL CORES UNDER
BEARING WITH GROUT FROM BOTTOM OF LINTEL TO 16" MINIMUM BELOW LINTEL.
2. THESE LINTELS ARE NOT DESIGNED FOR MASONRY WALLS THAT CARRY FLOOR LOAD.
th re e i n c h e s o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t 1 2 3 4 5
Drawing Title:Seal:
ARCHITECT / ENGINEERS:
Project Title:
Date:
Project Number:
Drawing Number:
Drawn:Checked:
Building Number:
D C
B A
Revisions:
8016 TOWER POINT DRIVE
CHARLOTTE, NC 28227
P 704.814.1320 F 704.321.0833
Project Phase:
D C
B A
1 2 3 4 5 6
Location:
CONSULTANTS:
Office of
Construction and Facilities
Management
LRSPC #16910
C:\Users\jlorch\Documents\16910 VAMC Clarksburg Parking Deck-Structural_jlorch.rvt
HDG PROJECT: 16013 S004
STRUCTURAL TYPICAL DETAILS
CONSTRUCTION DOCUMENTS 100%
CONSTRUCT PARKING
STRUCTURE
MAY 14, 2018 JARMSR
LOUIS A. JOHNSON VAMC
540-320
1.1
3/4" = 1'-0"A4
TYP. ISOLATION JOINT
3/4" = 1'-0"A1
TYP. CORNER REINFORCING
3/4" = 1'-0"A3
TYP. REINF. @ MAS. WALL
OPNG.
3/4" = 1'-0"A2
JT REINF. LAP SPLICE
1 82 3 5 6 7
A
B
C
4 4.5 5.7
243'-0"
'-0
'-0
4'
-0
49'-6" 36'-0" 15'-0" 36'-0" 36'-0" 36'-0" 34'-6"
24'-0" 12'-0" 30'-6" 5'-6"
48" DIA. 996'-0"
13'-0 321k
996'-0"
10'-0
42" DIA.
48" DIA. 996'-0"
13'-0
48" DIA. 996'-0"
10'-0
48" DIA. 996'-0"
13'-0 321k
48" DIA. 996'-0"
13'-0 368k
48" DIA. 996'-0"
13'-0
66" DIA. 996'-0"
15'-0 631k
54" DIA. 991'-0"
13'-0
60" DIA. 991'-0"
15'-0
60" DIA. 991'-0"
15'-0
54" DIA. 991'-0"
13'-0
54" DIA. 996'-0"
13'-0 454k
48" DIA. 996'-0"
13'-0
54" DIA. 994'-0"
10'-0 400k
60" DIA. 984'-0"
15'-0 556k
48" DIA. 982'-0"
10'-0
60" DIA. 988'-0"
15'-0
60" DIA. 981'-0"
13'-0 530k
54" DIA. 983'-0"
13'-0 409k
54" DIA. 978'-0"
13'-0 427k
48" DIA. 979'-0"
10'-0
66" DIA. 977'-0"
13'-0 584k
48" DIA. 979'-0"
10'-0
66" DIA. 981'-0"
13'-0 586k
48" DIA. 982'-0"
10'-0
54" DIA. 985'-0"
13'-0 439k
985'-0"
13'-0
48" DIA.
375k
60" DIA. 987'-0"
13'-0 496k
48" DIA. 987'-0"
13'-0 365k
42" DIA. 987'-0"
10'-0
54" DIA. 987'-0"
13'-0
66" DIA. 984'-0"
15'-0
66" DIA. 987'-0"
15'-0
54" DIA. 987'-0"
13'-0
66" DIA. 991'-0"
13'-0 614k
60" DIA. 985'-0"
13'-0 496k
48" DIA. 991'-0"
13'-0 496k
60" DIA. 981'-0"
15'-0 565k
987'-0"
10'-0
48" DIA. 988'-0"
10'-0
48" DIA. 987'-0"
10'-0
42" DIA.
B4
S301
B4
S301
B4
S301
B5
S301
B5
S301
B5
S301 B5
S301
B5
S301
C2
S301
C2
S301C3
S301
C3
S301
HSS8x4x5/16"
B1
S302
B2
S302
B5
S302
CJ CJ
CJ CJ
CJ CJ
CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
T/SLAB = 1000.0' 42" DIA. 996'-0"
10'-0
42" DIA. 987'-0"
10'-0
SIM
48" DIA. 987'-0"
10'-0
SEE NOTE 7
C5
S301
C1
S302
C2
S302
C2
S302
C3
S302
C3
S302
C3
S302
SIM
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
SEE NOTE 7
T/SLAB = 992' - 9"
B4
S301
'-6
1'
-6
14'-8"11'-9 7/8"
24'-9"
'-0
'-0
4"
'-2
27'-4"
'-0
'-0
10'-6"
3'-11 3/4"
26'-0 1/4" th re e i n c h e s o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t 1 2 3 4 5
Drawing Title:Seal:
ARCHITECT / ENGINEERS:
Project Title:
Date:
Project Number:
Drawing Number:
Drawn:Checked:
Building Number:
D C
B A
Revisions:
8016 TOWER POINT DRIVE
CHARLOTTE, NC 28227
P 704.814.1320 F 704.321.0833
Project Phase:
D C
B A
1 2 3 4 5 6
Location:
CONSULTANTS:
Office of
Construction and Facilities
Management
PROJECT
NORTH
TRUE
NORTH
LRSPC #16910
C:\Users\jlorch\Documents\16910 VAMC Clarksburg Parking Deck-Structural_jlorch.rvt
HDG PROJECT: 16013 S101
FOUNDATION PLAN
CONSTRUCTION DOCUMENTS 100%
CONSTRUCT PARKING
STRUCTURE
MAY 14, 2018 JARMSR
LOUIS A. JOHNSON VAMC
540-320
1.1
GROUND LEVEL FOUNDATION PLAN NOTES:
1. DATUM (+0'-0") IS SET AT FIRST LEVEL ARCHITECTURALLY DEFINED FINISHED FLOOR ELEVATION
PROJECT CIVIL DRAWING).
2. ELEVATIONS FOR FOUNDATION ELEMENTS SUCH AS BOTTOM OF CAISSONS, TOP OF FOOTINGS, ESTIMATED BOTTOM OF EXISTING UNSUITABLE FILL, BASE OF WALLS, BOTTOM OF ELEVATOR PITS, ETC., ARE REFERENCED AS + OR - FROM DATUM ELEVATION. (i.e. T/SL +2'-6", T/W -5'-3", T/STL -6 1/4", ETC.)
3. CAISSON TO EXTEND TO A MINIMUM ELEVATION OF 978.0' AND HAVE SOCKETS INTO ROCK AS NOTED ON PLAN
(I.E. WITH 10'-0" ROCK SOCKET BOTTOM OF CAISSON WILL BE AT ELEVATION 968.0')
4. CAISSONS ARE NOTED ON PLAN WITH THE FOLLOWING DESIGNATIONS:
1/8" = 1'-0"D3
FOUNDATION PLAN
NOTE:
PRECAST TEES AND BEAMS
ARE TO BE DESIGNED TO
SUPPORT TOW TRUCKS AND
EMERGENCY VEHICLES.
SIZE T/CAISSON
ROCK SOCKET
DEPTH BELOW
978.0'
TOTAL
LOAD
5. TOP OF PIER ELEVATIONS ARE SHOWN ON PLAN. THIS ELEVATION VARIES DEPENDING ON THE FINISH FLOOR
ELEV. DEPTH OF GRADE BEAM BEARING ON THE PIER, OR CAP REQUIREMENTS.
6. T/FTG ELEVATIONS ARE SHOWN ON PLAN FOR STRIP AND SPREAD FOOTINGS. FOOTING STEPS ARE SHOWN IN RELATIVE LOCATIONS FROM DATUM (0'-0") U.N.O. SEE SHEET S003 & S004 "TYPICAL DETAILS" FOR FOOTING
STEP AND SPACING REQUIREMENTS.
7. TYPICAL FIRST LEVEL SLAB ON GRADE (S.O.G.) IS 5" NORMAL WEIGHT CONCRETE U.N.O. ON PLAN.
REINFORCE ALL S.O.G. WITH #4@18" O.C. EACH WAY ON 4" CRUSHED STONE BASE. SEE ARCH. DWGS.
AND SPECIFICATIONS FOR MOISTURE BARRIER/RETARDER.
8. AT SLOPING GRADE BEAMS PROVIDE BOTTOM OF GRADE BEAM ELEVATION TO MATCH T/PIER ELEVATION
NOTED AT EACH END. OTHER GRADE BEAMS ARE LEVEL AT T/GB ELEVATION NOTED ON PLAN.
9. REFER TO DRAWING S301 FOR DRILLED PIER SCHEDULE AND DETAIL.
A
B
C
4.5
4.5
5.7
5.7
243'-0"
RAMP
DOWN
RAMP
UP
SHEARWALL
S H
E A
R W
A
LL
T/SLAB
=1000.0'
RAMP
DOWN
SHEARWALL
RAMP
UP
T/SLAB=
1005'-5 1/4"
S H
E A
R W
A
LL
49'-6" 36'-0" 15'-0" 36'-0" 36'-0" 36'-0" 34'-6"
24'-0" 12'-0" 30'-6" 5'-6"
4'
-0
'-0
'-0