36C24420Q0099-005.pdf

PDF Posted

Attached to
CHILLER RENTAL Erie VAMC
Solicitation number
36C24420Q0099
Issued by

About this file

36C24420Q0099 Sow Attachment A Dry Cooler Close.pdf

View the file

Other files

File Type Posted
36C24420Q0099-0001002.docx DOCX document
36C24420Q0099-0001000.docx DOCX document
36C24420Q0099-0001001.docx DOCX document
36C24420Q0099-009.pdf PDF
36C24420Q0099-001.docx DOCX document
36C24420Q0099-003.docx DOCX document
36C24420Q0099-008.pdf PDF
36C24420Q0099-002.pdf PDF
36C24420Q0099-000.docx DOCX document
36C24420Q0099-010.pdf PDF
36C24420Q0099-004.xlsx XLSX spreadsheet
36C24420Q0099-006.pdf PDF
36C24420Q0099-007.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseArchitect/Engineer of Record StampConsultant

321 4 5 6 7 8 9 10

Sprinkler Status

G001

COVER SHEET

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

WWW.AE-WORKS.COM

AE WORKS PROJECT #: 18017

REPLACE IT HVAC HEAT

EXCHANGER

135 East 38th Street, Erie, PA 16504

562-18-401

05/10/2019 CJC CJC

100% CONSTRUCTION

DOCUMENTS

ERIE VA MEDICAL CENTER

REPLACE IT HVAC HEAT EXCHANGER

135 EAST 38TH STREET

ERIE, PA 16504

VICINITY MAP

SITE

LOCATION MAP

SITE

PROJECT DIRECTORY

OWNER:

ERIE VA MEDICAL CENTER

135 EAST 38TH STREET

ERIE, PA 16504

CONTACTS:

COR: PHILIP TSANG - (814) 860-2207

CO: DONALD KALIVODA - (814) 860-2917

ARCHITECT/ENGINEER:

AE WORKS LTD.

209 SANDUSKY ST

PITTSBURGH, PA 15212

(412) 287-7333

CONTACTS:

PROJECT LEAD: CHRIS CHAMPAGNE, PE

PM: TIFFANY HAILE

VA PROJECT: 562-18-401

NORTH

NORTH

DRAWING INDEX

SHEET # SHEET NAME

GENERAL

G001 COVER SHEET

CIVIL

C101 UTILITY SITE DRAINAGE

MECHANICAL

M001 HVAC SYMBOLS, ABBREVIATIONS AND GENERAL NOTES

MD10B BASEMENT MECHANICAL DEMOLITION PLAN

MD101 FIRST FLOOR MECHANICAL DEMOLITION PLAN

M10B BASEMENT MECHANICAL PLAN

M101 FIRST FLOOR MECHANICAL PLAN

M501 HVAC DETAILS

M502 HVAC DETAILS

M601 HVAC CONTROLS

M701 HVAC SCHEDULES

ELECTRICAL

E000 ELECTRICAL SYMBOLS AND ABBREVIATIONS

E101 ELECTRICAL POWER PLAN - DEMOLITION AND NEW

E601 ELECTRICAL ONE-LINE DIAGRAM

E800 ELECTRICAL SCHEDULES

# Revisions Date

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseArchitect/Engineer of Record StampConsultant

321 4 5 6 7 8 9 10

Sprinkler Status

C101

UTILITY SITE DRAINAGE

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

WWW.AE-WORKS.COM

AE WORKS PROJECT #: 18017

REPLACE IT HVAC HEAT

EXCHANGER

135 East 38th Street, Erie, PA 16504

562-18-401

05/10/2019 TLP TLP

100% CONSTRUCTION

DOCUMENTS

NOT TO SCALE

SITE PLAN

L

J

PB

XX-1

K

O S

M C

T T D

D

J

P

P

J

R

OS

LS

P C

T C

H

T

W D

S S

V M

F F

F F

F F S

F

P Z

I F R

T

E S

M L

D C

C L

C R

M D

E B

D S

P 2

P 2

N

1P 1 POLE (2P, 3P, 4P, ETC.)

A AMPERE

AC ABOVE COUNTER OR AIR

CONDITIONER

ACLG ABOVE CEILING

ADO AUTOMATIC DOOR OPENER

AF AMP FRAME

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFI ARC FAULT CIRCUIT INTERRUPTER

AHU AIR HANDLING UNIT

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

AMPL AMPLIFIER

ANNUN ANNUNCIATOR

APPROX APPROXIMATELY

AQ-STAT AQUASTAT

ARCH ARCHITECT, ARCHITECTURAL

AS AMP SWITCH

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BATT BATTERY

BD BOARD

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

C CONDUIT

CAB CABINET

CAT CATALOG

CATV CABLE TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CKT CIRCUIT

CLG CEILING

COMB COMBINATION

CMPR COMPRESSOR

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUATION OR CONTINUOUS

CONTR CONTRACTOR

CONV CONVECTOR

CP CIRCULATING PUMP

CRT CATHODE-RAY TUBE

CT CURRENT TRANSFORMER

CTR CENTER

CU COPPER

DCP DOMESTIC WATER CIRCULATING PUMP

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DISC DISCONNECT

DIST DISTRIBUTION

DN DOWN

DPR DAMPER

DS SAFETY DISCONNECT SWITCH

DT DOUBLE THROW

DWG DRAWING

EC ELECTRICAL CONTRACTOR

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

EM EMERGENCY

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

EP ELECTRIC PNEUMATIC

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EXIST EXISTING

EXH EXHAUST

EXP EXPLOSION PROOF

FA FIRE ALARM

FABP FIRE ALARM BOOSTER POWER

SUPPLY PANEL

FACP FIRE ALARM CONTROL PANEL

FCU FAN COIL UNIT

FIXT FIXTURE

FLR FLOOR

FLUOR FLUORESCENT

FU FUSE

FUDS FUSED SAFETY DISCONNECT SWITCH

GA GAUGE

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFI GROUND FAULT CIRCUIT

INTERRUPTER

GFP GROUND FAULT PROTECTOR

GND GROUND

GRS GALVANIZED RIGID STEEL (CONDUIT)

GYP BD GYPSUM BOARD

HOA HANDS-OFF-AUTOMATIC SWITCH

HORIZ HORIZONTAL

HP HORSEPOWER

HPF HIGH POWER FACTOR

HT HEIGHT

HTG HEATING

HTR HEATER

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING AND

AIR CONDITIONING

HWP HYDRONIC WATER PUMP

IC INTERRUPTING CAPACITY

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

INCAND INCANDESCENT

IR INFRARED

I/W INTERLOCK WITH

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT-AMPERE

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

LOC LOCATE OR LOCATION

LT LIGHT

LTG LIGHTING

LTNG LIGHTNING

LV LOW VOLTAGE

MAX MAXIMUM

MAG.S MAGNETIC STARTER

M/C MOMENTARY CONTACT

MC MECHANICAL CONTRACTOR

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDC MAIN DISTRIBUTION CENTER

MDP MAIN DISTRIBUTION PANEL

MFR MANUFACTURER

MFS MAIN FUSED DISCONNECT SWITCH

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MMS MANUAL MOTOR STARTER

MOA MULTIOUTLET ASSEMBLY

MSP MOTOR STARTER PANELBOARD

MSBD MAIN SWITCHBOARD

MT MOUNT

MT.C EMPTY CONDUIT

MTS MANUAL TRANSFER SWITCH

MTR MOTOR, MOTORIZED

N.C. NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

NFDS NON-FUSED SAFETY

DISCONNECT SWITCH

NIC NOT IN CONTRACT

NL NIGHT LIGHT

N.O. NORMALLY OPEN

NPF NORMAL POWER FACTOR

NTS NOT TO SCALE

OH OVERHEAD

OL OVERLOADS

PA PUBLIC ADDRESS

PB PULL BOX OR PUSHBUTTON

PE PNEUMATIC ELECTRIC

PED PEDESTAL

PF POWER FACTOR

PH PHASE

PIV POST INDICATING VALVE

PNL PANEL

PP POWER POLE

PR PAIR

PRI PRIMARY

PROJ PROJECTION

PRV POWER ROOF VENTILATOR

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE (CONDUIT)

PWR POWER

QUAN QUANTITY

RCPT RECEPTACLE

REQD REQUIRED

RM ROOM

RSC RIGID STEEL CONDUIT

RTU ROOF TOP UNIT

SC SURFACE CONDUIT

SEC SECONDARY

SHT SHEET

SIM SIMILAR

S/N SOLID NEUTRAL

SPEC SPECIFICATION

SPKR SPEAKER

SP SPARE

SR SURFACE RACEWAY

SS STAINLESS STEEL

SSW SELECTOR SWITCH

S/S STOP/START PUSHBUTTONS

STA STATION

STD STANDARD

SURF SURFACE MOUNTED

SW SWITCH

ELECTRICAL ABBREVIATIONS LIST

SWBD SWITCHBOARD

SYM SYMMETRICAL

SYS SYSTEM

TEL TELEPHONE

TERM TERMINAL

TL TWIST LOCK

TR TAMPER RESISTANT

T-STAT THERMOSTAT

TTC TELEPHONE TERMINAL CABINET

TV TELEVISION

TVTC TELEVISION TERMINAL CABINET

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UT UNDERGROUND TELEPHONE

UTIL UTILITY

UV UNIT VENTILATOR OR ULTRAVIOLET

V VOLT

VA VOLT-AMPERES

VDT VIDEO DISPLAY TERMINAL

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W WATT

W/ WITH

WG WIRE GUARD

WH WATER HEATER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFR TRANSFER

@ AT

' FEET

" INCHES

# NUMBER

Ø PHASE

C CENTER LINE

P PLATE

NOTE: NOT ALL SYMBOLS ARE NECESSARILY USED IN DRAWINGS.

SYMBOL

RELAY

SYMBOL SYMBOL SYMBOL

ELECTRICAL SYMBOL LEGEND

J

2 POLE SINGLE THROW SW.

SINGLE POLE SW.

LIGHT ON CORD REEL (TYPE DENOTED)

LIGHTING CHANNEL WIRE (TYPE DENOTED)

DIMMER SWITCH

MOMENTARY CONTACT SWITCH

OCCUPANCY SENSOR SWITCH

PUSH BUTTON

SINGLE RECEPT.

TIME DELAY SWITCH

SPLIT DUPLEX RECEPT.

FOURPLEX RECEPT.

DUPLEX RECEPT.

RECEPT ON EMERGENCY CKT (DUPLEX SHOWN)

ISOLATED GROUND RECEPT (DUPLEX SHOWN)

240 VOLT RECEPT.

RECEPT ON DROP CORD (DUPLEX SHOWN)

RECEPT ON CORD REEL (DUPLEX SHOWN)

FLOOR RECEPT. (DUPLEX SHOWN)

TIMER SWITCH

KEYED SW.

SW. W/PILOT

3-WAY SW.

4-WAY SW.

DESCRIPTION

WALL MOUNTED FLOODLIGHT (TYPE DENOTED)

POLE MOUNTED LIGHT (TYPE DENOTED)

RECESSED LIGHT (TYPE DENOTED)

SURFACE LIGHT (TYPE DENOTED)

EXIT SIGN (TYPE DENOTED)

SUSPENDED OR PENDANT LIGHT (TYPE DENOTED)

TRACK AND TRACK LIGHT (TYPES DENOTED)

SURFACE LINEAR LIGHT (TYPE DENOTED)

STRIP LIGHT (TYPE DENOTED)

EMERGENCY BATTERY LIGHT (TYPE DENOTED)

RECESSED LINEAR LIGHT (TYPE DENOTED)

POLE MOUNTED FLOODLIGHT (TYPE DENOTED)

FOURPLEX RECEPTACLE ON EMERGENCY CIRCUIT

LIGHT FIXTURE ON (EM) LIFE SAFETY BRANCH

LIGHT FIXTURE ON (EM) CRITICAL BRANCH

CIRCUIT BREAKER PANEL

DASHED SYMBOL INDICATES REMOVED

HALFTONE SYMBOL INDICATES EXISTING

SOLENOID VALVE

BUS DUCT WITH PLUG IN DISCONNECT (FUSED)

LIGHT LEVEL SENSOR - TYPE DENOTED

TIME CONTROL SWITCH (TIME SWITCH)

HUMIDISTAT

THERMOSTAT

PHOTOCELL

ENCLOSED CIRCUIT BREAKER

PRESSURE SWITCH

SAFETY DISC. SW. (FUSED)

SAFETY DISC. SW. (NON-FUSED)

COMB. MOTOR STARTER (FUSED)

POWER OR DISTRIBUTION PANEL

MOTOR (SEE SCHEDULE)

TRANSFORMER (TYPE DENOTED)

STATIC GROUND RECEPTACLE (TYPE DENOTED)

SPECIAL RECEPT. OR CONN. (SEE SCHEDULE)

JUNCTION BOX

PULL BOX

GROUND ROD (PLAN VIEW)

LIGHTNING PROTECTION AIR TERMINAL

SURGERY SERVICE COLUMN

CLOCK (TYPE DENOTED)

POWER POLE (OPEN OFFICE STYLE)

MULTIOUTLET ASSEMBLY (TYPE DENOTED)

DESCRIPTION

LIGHTNING PROTECTION CONDUCTOR SPLICE

UTILITY SERVICE POWER POLE (SITE)

OCCUPANCY SENSOR - TYPE DENOTED

FLOAT SWITCH

ANTENNA

DOOR SIGNAL - APT. UNIT

SPEAKER (WALL OR CEILING MT.)

MICROPHONE OUTLET

HORN TYPE SPEAKER

VOLUME CONTROL

BUZZER

BELL

INFORMATION OUTLET (TYPE DENOTED)

WALL TELEPHONE OUTLET (TYPE DENOTED)

TELEPHONE OUTLET (TYPE DENOTED)

TELEVISION OUTLET

DESCRIPTION

CHIME

WIRELESS ACCESS POINT

DESCRIPTION

GAS DETECTOR (TYPE DENOTED)

F.A. PULLSTATION (TYPE DENOTED)

F.A. DOOR CLOSER

F.A. DOOR HOLDER

F.A. INDIVIDUAL ADDRESSABLE MODULE

FIRE ALARM SHUT DOWN RELAY

SPRINKLER VALVE TAMPER SWITCH

SPRINKLER FLOW SWITCH

F.A. ZONE ADDRESSABLE MODULE

SPRINKLER TEMPERATURE SWITCH

SPRINKLER LEVEL SWITCH

SPRINKLER PRESSURE SWITCH

HEAT DETECTOR (TYPE & TEMP DENOTED)

FIRE ALARM BELL

FIRE ALARM BELL W/STROBE (CANDELAS)

SMOKE DETECTOR (TYPE DENOTED)

FIRE ALARM STROBE (CANDELAS)

FIRE ALARM SPEAKER W/STROBE (CANDELAS)

FLAME DETECTOR (TYPE DENOTED)

DUCT SMOKE DETECTOR (TYPE DENOTED)

REMOTE TEST/STATUS STATION

LINEAR HEAT DETECTOR

FIRE ALARM CHIME W/STROBE (CANDELAS)

FIRE ALARM HORN W/STROBE (CANDELAS)

FIRE ALARM REMOTE ANNUNCIATOR

END OF LINE RESISTOR

CCTV CAMERA WITH PAN/TILT DRIVE

CCTV CAMERA

NURSE CALL DOME LIGHT (2 LAMP)

DOOR CONTACTS

CARD READER

ELECTRIC STRIKE

MOTION DETECTOR (TYPE DENOTED)

NURSE CALL EMERG. STATION

NURSE CALL DUTY STATION

NURSE CALL STAFF STATION

NURSE CALL CODE BLUE EMERG. STATION

NURSE CALL SINGLE PATIENT STATION

NURSE CALL DUAL PATIENT STATION

KEYPAD

MAGNETIC LOCK

COMBINATION LOCK

1 KEYED NOTE (SEE SCHEDULE)

NOTE: NOT ALL SYMBOLS ARE NECESSARILY USED IN DRAWINGS.

1. THE FOLLOWING GENERAL NOTES AS LISTED BELOW SHALL APPLY TO ALL ELECTRICAL REQUIREMENTS AS INDICATED ON ALL E

SERIES CONTRACT DRAWINGS.

2. THE CONTRACTOR IS RESPONSIBLE FOR THE ENTIRE DOCUMENT SET I.E. IF WORK IS SHOWN ON OTHER DRAWINGS AS "BY

CONTRACTOR" THE CONTRACTOR IS RESPONSIBLE FOR THAT WORK.

3. DRAWINGS FOR THIS WORK ARE DIAGRAMMATIC AND INTENDED TO CONVEY THE GENERAL EXTENT, ARRANGEMENT AND LOCATIONS OF THE WORK. BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS SUCH AS ACCESS PANELS, CONDUITS, CABINET SIZES, PENETRATION SLEEVES, PULL BOXES, BACKBOXES AND JUNCTION BOXES MAY NOT BE SHOWN.

INCLUDE ALL ITEMS WHERE REQUIRED BY CODE, MANUFACTURER AND RELATED SPECIFICATION SECTIONS FOR THE PROPER

INSTALLATION OF ALL WORK.

4. DUE TO SCALE OF THE DRAWINGS, ALL ELECTRICAL DEVICE SYMBOLS ARE SHOWN ON DRAWINGS AS CLOSE AS POSSIBLE TO THEIR INTENDED LOCATION. CONTRACTOR SHALL COORDINATE IN THE FIELD THE PROPER INSTALLATION OF ALL EQUIPMENT, DEVICES, CONTROLS AND CONDUITS. REFER TO RELATED SPECIFICATION SECTIONS FOR ADDITIONAL REQUIREMENTS.

5. COORDINATE WITH ALL TRADES AND SYSTEM INTEGRATORS ANY CONDITIONS RELATED TO THE INSTALLATION OF ALL SYSTEMS. THE CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE TRADE ALL INSTALLATION REQUIREMENTS IMPACTING THE PLACEMENT OF ALL SYSTEM COMPONENTS TO THE SATISFACTION OF ALL CONCERNED TRADES.

6. ALL CONDUITS SHALL BE SIZED AND INSTALLED IN ACCORDANCE WITH NFPA 70 AND PROJECT SPECIFICATIONS. ALL CONDUITS

SHALL BE A MINIMUM OF 3/4" UNLESS OTHERWISE NOTED.

7. PROVIDE ALL EQUIPMENT CLEARANCES IN ACCORDANCE WITH NEC REQUIREMENTS. ARRANGE EQUIPMENT TO FACILITATE UNRESTRICTED ACCESS FOR MAINTENANCE AND SERVICE AROUND ALL EQUIPMENT, COMPONENTS AND/OR CABLE

TERMINATIONS.

8. WHERE EQUIPMENT AND/OR JUNCTION BOXES ARE INSTALLED ABOVE FINISHED CEILINGS, THE CONTRACTOR SHALL PROVIDE ACCESS HATCHES LISTED FOR THE INTENDED APPLICATION. ACCESS HATCHES SHALL BE LOCATED SO THAT SERVICE ACCESS

TO THE EQUIPMENT AND/OR JUNCTION BOXES IS UNIMPEDED.

9. ALL PENETRATIONS OF WALLS AND/OR FLOORS SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE ASTM AND NFPA REQUIREMENTS. REFER TO RELATED SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION. INSTALLATION OF FIRE-STOPS SHALL BE PERFORMED BY APPLICATOR/INSTALLER QUALIFIED AND TRAINED BY THE MANUFACTURER. INSTALLATION SHALL BE PERFORMED IN STRICT ACCORDANCE WITH MANUFACTURER'S DETAILED INSTALLATION PROCEDURES.

10. ALL EQUIPMENT ENCLOSURES LOCATED OUTSIDE OR IN ALL AREAS WITH HIGH MOISTURE OR A RELATIVE HUMIDITY OF 75% OR

GREATER SHALL BE NEMA 4X STAINLESS STEEL AND RATED FOR THAT APPLICATION.

11. ALL INTERIOR AND/OR EXTERIOR COMPONENTS, DEVICES OR SYSTEMS EQUIPMENT EXPOSED TO THE GENERAL POPULATION SHALL BE INSTALLED IN SECURED EQUIPMENT ENCLOSURES WITH TAMPER SWITCHES AND INSTALLED IN SUCH A MANNER THAT

RESISTS TAMPERING AND/OR REMOVAL WITHOUT THE USE OF SPECIALIZED TOOLS.

12. FOR EQUIPMENT INSTALLATIONS REQUIRING COORDINATION WITH OTHER TRADES THE CONTRACTOR SHALL PROVIDE ALL TEMPLATES, BACKBOXES AND EQUIPMENT ANCHOR BOLTS FOR MOUNTING OR FLUSH MOUNTING PREPARATION, (E.G.

PEDESTALS OR OTHER DEVICES REQUIRING MOUNTING ON WALLS, CONCRETE PADS OR OTHER MATERIALS). COORDINATE

DELIVERY OF TEMPLATES AND EQUIPMENT WITH ALL AFFECTED CONTRACTORS.

13. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (LATEST VERSION BEING ENFORCED), AND ALL OTHER APPLICABLE CODES AND STANDARDS BEING ENFORCED BY THE AUTHORITY HAVING

JURISDICTION.

14. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS OR INSTRUCTIONS FOR CONSTRUCTION SAFETY. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR ANY WORKMAN'S OR TRANSIENT'S SAFETY, OR FOR THE ADEQUACY OF EQUIPMENT, BUILDING COMPONENTS, WORK AIDS, OR ANY NECESSITY TO WORK ON ENERGIZED ELECTRICAL COMPONENTS.

FURTHER, NO SUPERINTENDENCE IS INCLUDED OR IMPLIED.

15. ALL SYSTEMS AND EQUIPMENT SHALL BE INSTALLED AND WIRED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS.

16. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE TESTED AND LISTED BY A NATIONALLY

RECOGNIZED TESTING LABORATORY.

17. THE CONTRACTOR SHALL COORDINATE CONDUIT ROUTING (PLAN AND ELEVATION) WITH THE LIGHTING (NEW AND EXISTING), CEILING ELEVATION, STRUCTURE, DUCTWORK, PIPING, ETC. REQUIRED FOR THE COMPLETION OF THE PROJECT, PRIOR TO

INSTALLATION.

18. THE CONTRACTOR SHALL SECURE AND PROTECT THE BUILDING AND/OR WORK AREA WITH FIRE RETARDANT TEMPORARY PLYWOOD PARTITIONS (WITH LOCKING DOORS), ETC. CLOSE ALL EXISTING OPENINGS AS REQUIRED. COORDINATE THIS WORK WITH THE VA COR PRIOR TO STARTING. IF TEMPORARY PARTITIONS IMPEDE THE FLOW OF EGRESS TO REQUIRED EGRESS DOORS AND STAIRS, THE CONTRACTOR SHALL PROVIDE EXIT SIGNS, AND SIGNAGE INDICATING SUCH.

19. THE CONTRACTOR SHALL CAULK ALL JOINTS BETWEEN METAL FRAMES AND EXISTING CONDITIONS. THIS APPLIES TO BOTH

INTERIOR AND EXTERIOR INSTALLATIONS.

20. THE DIMENSIONS SHOWN ON THE DRAWINGS ARE FOR THE CONVENIENCE OF THE CONTRACTOR ONLY. VERIFY ALL DIMENSIONS

IN THE FIELD PRIOR TO PERFORMING ANY WORK.

21. THE CONTRACTOR SHALL INSTALL ALL CONDUITS CONCEALED UNLESS NOTED OTHERWISE. EXPOSED CONDUIT SHALL ONLY BE INSTALLED IN CHASES, EXPOSED CEILING AREAS, JANITOR CLOSETS, AND MECHANICAL/ELECTRICAL ROOMS.

22. ALL ELECTRICAL EQUIPMENT SHALL BE GROUNDED AND/OR BONDED PER THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE. PROVIDE ALL GROUNDING AND/OR BONDING COMPONENTS NOT EXPLICITLY SHOWN ON THE DOCUMENTS.

23. THE CONTRACTOR SHALL PROVIDE UPDATED TYPED PANELBOARD DIRECTORIES, INDICATING THE LOADS SERVED BY THE RESPECTIVE PANELS. AMEND AS REQUIRED FOR AS-BUILT CONDITIONS. PROVIDE ELECTRONIC VERSIONS OF THE PANELBOARD

SCHEDULES FOR FUTURE USE BY THE OWNER.

24. THE CONTRACTOR SHALL REVIEW THE WORK REQUIRED WITH THE APPLICABLE UTILITY COMPANIES SERVING THE PROJECT.

ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE INDIVIDUAL UTILITY COMPANIES.

25. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH THE OWNER PRIOR TO STARTING ALL PHASES OF THE PROJECT. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER WHAT WORK, IF ANY, HAS TO BE COMPLETED DURING SECOND OR THIRD

SHIFT.

26. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY POWER CONNECTIONS TO KEEP AREAS UP AND OPERATIONAL DURING THE

CONSTRUCTION. THE CONTRACTOR SHALL COORDINATE THESE REQUIREMENTS WITH THE OWNER.

27. THE VERBIAGE ON THE DRAWINGS INDICATING TYPES OF MATERIALS TO BE ENCOUNTERED IS INTENDED TO AID THE ELECTRICAL CONTRACTOR IN UNDERSTANDING THE VARIOUS CONDITIONS LIKELY TO BE ENCOUNTERED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING QUANTITIES OF MATERIALS REQUIRED TO COMPLETE THE PROJECT.

28. THE LOCATIONS OF EXISTING UTILITIES, STRUCTURE AND OTHER CONDITIONS SHOWN ON THE PLANS ARE APPROXIMATE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY AND REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR

TO BEGINNING ANY WORK.

29. FURNISH AND INSTALL ALL REQUIRED LINTELS AND SLEEVES. ALL CONDUITS SHALL HAVE SLEEVES INSTALLED. ALL SLEEVES

INSTALLED THROUGH EXTERIOR WALLS SHALL HAVE LINK SEALS INSTALLED.

30. THE CONTRACTOR SHALL GENERATE A DETAILED METHOD OF PROCEDURE (MOP) DOCUMENT INDICATING HOW HE/SHE INTENDS TO PERFORM EACH STEP IN THE PROJECT. THIS MOP SHALL BE PRESENTED TO THE OWNER AND ENGINEER PRIOR TO STARTING THE PROJECT, FOR SIGN OFF. THE MOP MAY BE REVISED BASED ON CHANGES IN THE PROJECT CONSTRUCTION, ETC.

AT ALL POINTS IN THE PROJECT THE OWNER SHALL BE MADE AWARE OF CHANGES TO THE MOP, AND A REVISED MOP SHALL BE

PRESENTED TO THE OWNER AND ENGINEER FOR SIGN OFF.

31. PROVIDE ALL JUNCTION BOXES, PULL BOXES AND OTHER PULL POINTS AS REQUIRED FOR EASE OF PULLING AND TO MEET THE MAXIMUM NUMBER OF BENDS PER NEC REQUIREMENTS FOR A CODE COMPLIANT INSTALLATION. NOT ALL CONDUITS, PULL BOXES AND OTHER RACEWAY ITEMS ARE INDICATED ON THE DOCUMENTS. THE CONTRACTOR SHALL PROVIDE A COMPLETE RACEWAY SYSTEM MEETING THE REQUIREMENTS OUTLINED IN THE DRAWINGS AND SPECIFICATIONS. ALL JUNCTION BOXES

AND OTHER PULL POINTS SHALL BE ACCESSABLE.

32. THESE DRAWINGS DO NOT INDICATE ALL CONDUITS INTERCONNECTING EQUIPMENT, AND WHERE CONDUITS ARE INDICATED, THE ROUTING IS APPROXIMATE. THE CONTRACTOR IS RESPONSIBLE FOR THE ROUTING AND INSTALLATION OF ALL CONDUIT IN

COORDINATION WITH OTHER TRADES AND EXISTING CONDITIONS.

33. MULTIWIRE BRANCH CIRCUITS ARE NOT PERMITTED, ALL SINGLE POLE BRANCH CIRCUITS SHALL HAVE A DEDICATED NEUTRAL.

SHARING OF NEUTRALS IS PROHIBITED. ALL CIRCUITS SHALL CONTAIN AN INDIVIDUAL GROUND WIRE. USE OF THE CONDUIT

SYSTEM FOR THE GROUND PATH IS PROHIBITED.

34. MULTIPLE SMALL 20A/1P BRANCH CIRCUITS MAY SHARE A SINGLE CONDUIT PROVIDED THE CONTRATOR UPSIZES THE WIRES, INCLUDING THE GROUND, AND CONDUIT AS REQUIRED PER NEC.

35. THE COMPLETE BRANCH WIRING SYSTEM IS NOT SHOWN ON THE DRAWINGS. AN ABBREVIATED FORMAT IS USED TO INDICATE WHICH FIXTURES/DEVICES ARE CONNECTED TO A COMMON CIRCUIT OR SWITCH. THIS IS PROVIDED AS A GUIDE TO THE CONTRACTOR TO ILLUSTRATE CIRCUITS AND CONTROL INTENT. ACTUAL WIRING MAY DIFFER DUE TO FIELD CONDITIONS.

COLOR CODING OF WIRES SHALL BE AS PER NEC.

36. DURING THE BIDDING PROCESS, THE ELECTRICAL CONTRACTOR SHALL REVIEW DRAWINGS AND SPECIFICATIONS OF ALL OTHER TRADES (ARCHITECTURAL, SITE/LANDSCAPING, HVAC, PLUMBING, AND SPECIALTY TRADES). ALL ITEMS REQUIRING POWER INDICATED ON THESE DRAWINGS BUT NOT INDICATED ON THE ELECTRICAL DRAWINGS SHALL BE CONSIDERED A PART OF THE ELECTRICAL CONTRACTOR’S WORK. THIS WORK SHALL BE INSTALLED AS PER NEC REQUIREMENTS AT NO ADDITIONAL COST TO

THE OWNER.

ELECTRICAL GENERAL NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseArchitect/Engineer of Record StampConsultant

321 4 5 6 7 8 9 10

Sprinkler Status

E000

ELECTRICAL SYMBOLS AND

ABBREVIATIONS209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

WWW.AE-WORKS.COM

AE WORKS PROJECT #: 18017

REPLACE IT HVAC HEAT

EXCHANGER

135 East 38th Street, Erie, PA 16504

562-18-401

05/10/2019 BK ARD

100% CONSTRUCTION

DOCUMENTS

CLNG

J

C L N G

J

5A

A B CB5

8.5

10.2

D E F G

H J K L M N ONBK5

5A

A B

C

B5

8.5

10.2

D E F G

H J K L M N ONBK5

STORAGE

EB-11A

Room

NB-60-6

OFFICE

EB-28A

DINING ROOM

NB-60

ELEV

P-3

OFFICE

EB-28

V-TEL

CONFERENCE

ROOM

EB-26A

MECH. ROOM

EB-25

STAIRS 'A'

FB-1C

ELEV.

F-5

OFFICE

EB-26

BREAK ROOM

NB-60-8

MENS LOCKER-1

NB-60-9

MENS LOCKER-2

NB-60-10 AIR COND. EQUIP

ROOM

NB-60-11

ELECTRICAL

SWITCH GEAR

NB-60-12

STORAGE

NB-60-13

MED GAS STORAGE

NB-60-14

MAIL ROOM

NB-60-16

ELEVATOR LOBBY

NB-60-17

Room

NB-60-18

Space

NB-60-19

Space

NB-60-20

TOILET

NB-60-21

TOILET

NB-60-22

IT OFFICE

NB-60-23

TOILET

WB-40E

TRAINING ROOM

NB-60-24

R.O.L.

NB-60-25

OFFICE

B-06

OFFICE

B-11

LIBRARY STORAGE

B-12

IT STORAGE

NB-60-26

IT SERVER ROOM

NB-60-27

SALE STOR.

NB-60-28

Space

NB-60-30

DAV OFFICE

NB-60-31

AMERICAN LEGION

NB-51

CLOSET

NB-51A

HAC

WB-48

TOILET ROOM

NB-49

OFFICE

NB-60-33

OFFICE

B-10

TOILET ROOM

NB-50

OFFICE

B-07

STORAGE-2

EB-7A-2

TOILETS

NB-60-34

ELEV-2

P-2-2

ELEVATOR LOBBY

EB-23

Space

NB-60-35

PHARMACY

RESIDENTS

EB-31

Space

NB-60-36

BREAK ROOM

NB-60-37

STAIR C-2

NB-44-2

MACHINE ROOM

NB-60-39 STORAGE

EB-7

STORAGE

EB-6

CANTEEN STORE

NB-46

STORAGE-2

EB-5-2

WORKSHOP-2

EB-09A-2

MECHANICAL

ROOM

NB-59

ELEC

NB-59A

FE CLOSET-2

NB-59B-2

ELEV-2

S-4-2

CORRIDOR-2

EB-8-2

STORAGE

EB-3

STORAGE

BB15C

STORAGE

BB15A

STORAGE

NB-60-46

Space

NB-60-47

OFFICE

NB-60-48

PIV OFFICE

B-01

IT OFFICE

NB-60-49

Space

NB-60-50

OFFICE

NB-60-51

MEDICAL RECORDS

NB-60-52

STORAGE

NB-60-53

Space

NB-60-54

STORAGE

NB-60-55

CALL CENTER

NB-60-56

POLICE

NB-60-57

CORRIDOR

WB-36

STORAGE

BA07B

Space

NB-60-59

IT WORK ROOM

BA13A

LIBRARY

NB-60-61

COMPUTER ROOM

BA07A

IT CHIEF

NB-60-63

SHOWER

NB-60-64

WOMENS LOCKER

NB-60-65

SOCIAL WORKER

OFFICE

NB-60-66

CHIEF POLICE

NB-60-67

OFFICE

NB-60-68

MECHANICAL

ROOM

BA13C

Space

NB-60-69

STORAGE

NB-60-70

SERVER ROOM

BB14

STORAGE

BB15B

SIGN SHOP-2

EB-09B-2

MACHINE ROOM

EB-11

LAUNDRY

EB-22

UP TO IT

CLOSET

ABOVE FCU-L6

WB-H

FCU-L3

FCU-L4

EQA

E101

E101

DC-2 DC-1

ET-2

ET-1

PP-2

PP-1

EXISTING

CONDENSING UNIT

E101

E101

DC-2 DC-1

ET-1

PP-2

PP-1

ET-2

WB-H-14,16,18

WB-H-8,10,12

WB-H-7,9,11

WB-H-1,3,5

30A/30AF/3P

PP-2 (P-1)

DC-1 PP-1 (P-1)

DC-2

30A/30AF/3P 60A/35AF/3P

60A/35AF/3P

EXISTING

CONDENSING UNIT

WB-H-2,4,6

WB-H-19,21,23

60A/35AF/3P

60A/35AF/3P

PP-1 (P-2)

PP-2 (P-2)

EXISTING

EXPANSION TANK

EXISTING

DRYCOOLERS

EXISTING CONDENSING

UNIT TO BE RELOCATED

EXISTING PUMPS

EXISTING

CONDENSING UNIT

1. EXISTING DEVICES SHOWN ARE DIAGRAMMATIC AND BASED ON FIELD SURVEYS

AND/OR RECORD DRAWINGS PROVIDED BY THE OWNER AND DO NOT REPRESENT THE

FULL SCOPE OF DEMOLITION WORK. THE ACTUAL CONDITIONS MAY VARY. ALL

EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO BID. THE PLANS ARE INTENDED TO

SHOW THE LOCATIONS OF EXISTING DEVICES AND IN NO WAY RELIEVE THE

CONTRACTOR FROM PROVIDING ANY AND ALL COORDINATION NECESSARY TO

COMPLETE THE NEW WORK. FIELD CONDITIONS SHALL GOVERN. FIELD VERIFY ALL

EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF WORK AND

OBTAIN CLARIFICATIONS FROM ARCHITECT/ENGINEER IF NECESSARY.

2. CONTRACTOR SHALL PROVIDE A MINIMUM TWO WEEKS WRITTEN NOTICE PRIOR TO

ANY SHUT DOWN. NOTICE IS TO INCLUDE BUT IS NOT LIMITED TO THE LOCATION,

PANELS AND DURATION OF SHUT DOWN.

3. OWNER SHALL HAVE RIGHT OF FIRST REFUSAL TO ANY EQUIPMENT, DEVICES, ETC.

DEMOLISHED FROM RENOVATION AREA PRIOR TO DISPOSAL.

4. MAINTAIN CONTINUITY OF SERVICE TO AREAS OUTSIDE THE PROJECT BOUNDARY.

PATCH AND REPAIR ALL CIRCUITS CUT OFF DURING DEMOLITION BY WIRING METHODS

COMPATIBLE WITH THE EXISTING INSTALLATION.

5. THE ELECTRICAL CONTRACTOR SHALL REVIEW THE DRAWING OF ALL OTHER TRADES

IN THIS CONTRACT. THE REMOVAL OF ELECTRICAL SERVICE TO ALL EQUIPMENT

IDENTIFIED ON OTHER TRADE DRAWINGS IS THE RESPONSIBILITY OF THE ELECTRICAL

CONTRACTOR.

6. EXERCISE EXTREME CAUTION WHEN REMOVING/ RELOCATING WIRING AND

EQUIPMENT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT OTHER

WIRING DEVICES AND EQUIPMENT THAT MAY BE CONNECTED TO THE SAME CIRCUIT

REMAIN OPERATIONAL AND ACTIVE.

7. PROTECT THE EXISTING EQUIPMENT THAT IS TO REMAIN IN PLACE FROM DIRT, DUST,

OR DAMAGE DURING THE COURSE OF DEMOLITION.

8. CONTRACTOR SHALL EXAMINE CONDITIONS AND TEST FUNCTIONALITIES OF ALL

EXISTING ELECTRICAL EQUIPMENT IDENTIFIED TO BE RE-USED AND/OR RELOCATED.

PROVIDE REPORT TO ENGINEER AND OWNER PRIOR TO

DEMOLITION.

ELECTRICAL DEMOLITION GENERAL NOTES

1. FINAL LOCATION OF ALL EQUIPMENT SHALL BE DETERMINED IN THE FIELD AND SHALL BE

INSTALLED AS DIRECTED BY THE ARCHITECT OR VA COR. WHERE STRUCTURAL OPENINGS

ARE NOT AVAILABLE, THE CONTRACTOR SHALL CORE DRILL WALLS AND FLOORS AS

REQUIRED TO PERMIT PASSAGE OF CONDUITS. THE ELECTRICAL CONTRACTOR SHALL

PROVIDE A MARKED-UP PLAN WITH LOCATION PENETRATIONS FOR REVIEW AND

APPROVAL OF THE VA COR BEFORE ROUGH-IN BEGINS.

2. DURING THE BIDDING PROCESS, THE ELECTRICAL CONTRACTOR SHALL REVIEW

DRAWINGS AND SPECIFICATIONS OF ALL OTHER TRADES (ARCHITECTURAL,

SITE/LANDSCAPING, HVAC, PLUMBING AND SPECIALTY TRADES). ALL ITEMS REQUIRING

POWER INDICATED ON THESE DRAWINGS BUT NOT INDICATED ON THE ELECTRICAL

DRAWINGS SHALL BE CONSIDERED A PART OF THE ELECTRICAL CONTRACTOR'S WORK.

THIS WORK SHALL BE INSTALLED AS PER NEC REQUIREMENTS AT NO ADDITIONAL COST

TO THE OWNER.

3. THE CONTRACTOR SHALL MAKE EVERY EFFORT TO MAKE ALL FEEDER RUNS CONTINUOUS

(NO CABLE BREAKS). IF SPLICING CABLES IN BOXES BECOMES NECESSARY, USE O.Z.G.

TYPE "XW" CABLE TAPS, OR APPROVED EQUAL, AND TAPE EACH TAP IN APPROVED

MANNER.

4. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL MECHANICAL

EQUIPMENT.

5. PROVIDE CONDUIT AND WIRING AS REQUIRED TO MEET CIRCUITING SHOWN TO CONFORM

TO NEC REQUIREMENTS.

6. PROVIDE EQUIPMENT GROUND CONDUCTOR IN ALL RACEWAYS. REFER TO PANELBOARD

SCHEDULES.

7. ROUTE CONDUIT HIGH AGAINST STRUCTURE AND OFFSET UP BETWEEN JOISTS WHERE

NECESSARY TO AVOID DUCT WORK AND HVAC SYSTEM.

8. VERIFY AND COORDINATE EXACT ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT WITH

MANUFACTURER'S RECOMMENDATIONS PRIOR TO INSTALLATION OF EQUIPMENT.

POWER PLAN GENERAL NOTES

DEDUCT ALTERNATE NO. 1

EXISTING 10 TON FCU INDOOR UNITS SHALL REMAIN. KEEP UNITS ON PANEL

WB-H. ALL WIRING AND CONDUIT ASSOCIATED WITH EQUIPMENT SHALL BE

EXISTING TO REMAIN.

THE NEW 10HP PUMPS SHALL BE 480V AND FED FROM PANEL EQA. PROVIDE A

20A/3P CIRCUIT BREAKER IN PANEL EQA FOR EACH PUMP (TOTAL 4). PROVIDE

A 30A/20AF/3P NEMA 3R LOCKABLE DISCONNECT SWITCH FOR EACH PUMP

LOCATED AT THE EQUIPMENT PAD. EXTEND (3) #12 & (1) #12 GRD IN 3/4”

CONDUIT FROM EQUIPMENT TO PANEL EQA LOCATED IN THE AMBULATORY

SURGERY CENTER PENTHOUSE.

THE NEW DRYCOOLERS SHALL BE 208V AND FED FROM PANEL WB-H. USE

EXISTING 30A/3P CIRCUIT BREAKERS IN PANEL WB-H TO POWER THE NEW

DRY COOLERS. PROVIDE A NEW 30A/30AF/3P NEMA 3R LOCKABLE

DISCONNECT SWITCH FOR EACH DRYCOOLER LOCATED AT THE EQUIPMENT

PAD. EXTEND (3) #10 & (1) #10 GRD IN 3/4” CONDUIT FROM EQUIPMENT TO

PANEL WB-H.

5A

5A

FCU-L3 (NEW)

FCU-L4 (NEW)

EQA-1,3,5

EQA-7,9,11

5A

5A

FCU-L3 (DEMOLITION)

FCU-L4 (DEMOLITION)

OVERHEAD

DOOR

OVERHEAD

DOOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseArchitect/Engineer of Record StampConsultant

321 4 5 6 7 8 9 10

Sprinkler Status

KEYPLAN

E101

ELECTRICAL POWER PLAN -

DEMOLITION AND NEW209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

WWW.AE-WORKS.COM

AE WORKS PROJECT #: 18017

REPLACE IT HVAC HEAT

EXCHANGER

135 East 38th Street, Erie, PA 16504

562-18-401

05/10/2019 BK ARD

100% CONSTRUCTION

DOCUMENTS

KEYNOTES

1 REMOVE EXISTING DISCONNECT SWITCHES. REMOVE CONDUIT

AND WIRING BACK TO PANEL.

2 RELOCATE EXISTING ELECTRICAL TO NEW LOCATION OF

CONDENSING UNIT.

3 REUSE 30A CIRCUIT BREAKER IN PANEL WB-H FOR NEW DRY

COOLERS.

4 REMOVE EXISTING CONDUIT AND WIRING BACK TO PANEL. MAKE

CIRCUITS SPARE.

5 COORDINATE LOCATION OF DISCONNECT SWITCHES WITH

MECHANICAL OUTDOOR CONTROL ENCLOSURES ALONG THIS

WALL. PROVIDE POWER TO NEW CONTROLS FROM THE

EXISTING CONTROL CIRCUITS.

6 PROVIDE ALL NEW DISCONNECT SWITCHES FOR ALL NEW

EQUIPMENT. DISCONNECTS SHALL BE NEMA 3R LOCKABLE AND

FUSED.

1/16" = 1'-0"E101

1 OVERALL BASEMENT ELECTRICAL PLAN

SECOND LEVEL PENTHOUSE -

AMBULATORY SURGERY CENTER

FIRST LEVEL

EQUIPMENT PAD

1/8" = 1'-0"E101

4 FIRST FLOOR EQUIPMENT PAD (NEW) - POWER

1/8" = 1'-0"E101

5 FIRST FLOOR EQUIPMENT PAD (DEMOLITION) - POWER

1/8" = 1'-0"E101

6 INDOOR UNIT (NEW) - POWER

1/8" = 1'-0"E101

7 INDOOR UNIT (DEMOLITION) - POWER

5 6

NORTH

TRUE NORTH=

PLAN

150.0°

# Revisions Date

VHAERITSANGP

Text Box Approximate location for replacement dry cooler/cooling tower/chiller. This cooling unit will need emergency power connection or a backup generator and manual transfer switch

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseArchitect/Engineer of Record StampConsultant

321 4 5 6 7 8 9 10

Sprinkler Status

E601

ELECTRICAL ONE-LINE DIAGRAM

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

WWW.AE-WORKS.COM

AE WORKS PROJECT #: 18017

REPLACE IT HVAC HEAT

EXCHANGER

135 East 38th Street, Erie, PA 16504

562-18-401

05/10/2019 BK ARD

100% CONSTRUCTION

DOCUMENTS

NOT TO SCALEE601

1 ELECTRICAL ONE LINE DIAGRAM - FOR REFERENCE ONLY

KEYNOTES

1 REPLACE EXISTING 200A CIRCUIT BREAKER WITH NEW 100% RATED 200A CIRCUIT

BREAKER.

GROUND

PHASE

CONDUCTOR CONDUIT

BREAKER

SIZE

80A

NOTE:

PROVIDE A CONDUCTOR PER BREAKER POLE. THESE ARE THE MINIMUM SIZES REQUIRED

FOR EACH CIRCUIT. CONTRACTOR TO MAKE ALL THE NECESSARY FIELD ADJUSTMENTS TO

COMPENSATE FOR VOLTAGE DROP.

IN GENERAL, VOLTAGE DROP FOR ANY BRANCH CIRCUIT SHALL NOT EXCEED 3%. VOLTAGE

DROP FOR ANY FEEDER SHALL NOT EXCEED 2%. WHERE VOLTAGE DROP EXCEEDS THESE

REQUIREMENTS, THE CONTRACTOR SHALL INCREASE THE SIZE OF THE CONDUCTORS AND

RACEWAY AS REQUIRED.

BRANCH CIRCUIT WIRING SCHEDULE

NEUTRAL

CONDUCTOR

1.

2.

70A

60A

50A

45A

40A

35A

30A

20A

1-1/2"

1-1/4"

1-1/4"

1"

1"

1"

1"

3/4"

3/4"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseArchitect/Engineer of Record StampConsultant

321 4 5 6 7 8 9 10

Sprinkler Status

E800

ELECTRICAL SCHEDULES

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

WWW.AE-WORKS.COM

AE WORKS PROJECT #: 18017

REPLACE IT HVAC HEAT

EXCHANGER

135 East 38th Street, Erie, PA 16504

562-18-401

05/10/2019 BK ARD

100% CONSTRUCTION

DOCUMENTS

1. NEW FCU-L3 & FCU-L4 WILL NEVER BE RUNNING SIMULTANEOUSLY.

2. MAIN CIRCUIT BREAKER SHALL BE UPGRADED TO 100% RATED. SEE ONE LINE DIAGRAM.

NOTES:

EST. DEMAND CURRENT: 184.0 A

CONNECTED CURRENT: 184.0 A

ESTIMATED DEMAND: 152976 VA

CONNECTED LOAD: 152976 VA

Other 47415 VA 100.00% 47415 VA

LOAD CLASSIFICATION CONNECTED DEMAND ESTIMATED PANEL TOTALS

TOTAL AMPS: 184 A 184.1 A 184 A

TOTAL LOAD: 51 kVA 51 kVA 51 kVA

41 11.1 0.0 42 -- -- SPACE

39 11.1 0.0 40 -- -- SPACE

EXISTING STERILIZER

SUBSTERILE 2S335

50 A 3

37 11.1 0.0 38 -- -- SPACE

SPACE -- -- 35 0.0 0.0 36 -- -- SPACE

SPACE -- -- 33 0.0 0.0 34 -- -- SPACE

SPACE -- -- 31 0.0 0.0 32 -- -- SPACE

SPACE -- -- 29 0.0 0.0 30 -- -- SPACE

SPACE -- -- 27 0.0 0.0 28 -- -- SPACE

SPACE -- -- 25 0.0 0.0 26 -- -- SPACE

23 0.0 5.8 24

21 0.0 5.8 22SPARE 30 A 3

19 0.0 5.8 20

3 40 A EXISTING RF-AMB-1

SPACE -- -- 17 0.0 0.0 18

SPACE -- -- 15 0.0 0.0 16

SPACE -- -- 13 0.0 0.0 14

3 30 A SPARE

11 0.0 10.0 12

9 0.0 10.0 10NEW FCU-L4 80 A 3

7 0.0 10.0 8

3 50 A

EXISTING 30 KVA

TRANSFORMER/PANEL

EQB

5 15.8 9.4 6

3 15.8 9.4 4NEW FCU-L3 80 A 3

1 15.8 9.4 2

3 60 A EXISTING SF-AMB-1

LOAD DESCRIPTION BKR P CKT

PHASE A

kVA

PHASE B

kVA

PHASE C

kVA CKT P BKR LOAD DESCRIPTION

BUS AMPS: 400 AMPS

MAIN DEVICE: 200.0 A MAIN CB SPECIAL:

MOUNTING: SURFACE NEMA 1 A.I.C. RATING: 14,000 AMPS SYMMETRICAL

LOCATION: VOLTAGE: 480Y/277 V. 3 ø 4 W.

PANELBOARD: EQA

LOAD REMOVED: 130.9A

LOAD ADDED: 106.4A

NOTES:

EST. DEMAND CURRENT: 0.0 A

CONNECTED CURRENT: 0.0 A

ESTIMATED DEMAND: 0 VA

CONNECTED LOAD: 0 VA

Other 0 VA 0.00% 0 VA

LOAD CLASSIFICATION CONNECTED DEMAND ESTIMATED PANEL TOTALS

TOTAL AMPS: 0 A 0.0 A 0 A

TOTAL LOAD: 0 kVA 0 kVA 0 kVA

23 0.0 0.0 24 1 20 A EXHAUST FAN (CT RM.)

21 0.0 0.0 22 1 20 A EXHAUST FAN (CT RM.)NEW PP-1 (P-2) 40 A 3

19 0.0 0.0 20 1 20 A SPARE TO JB IN CEILING

17 0.0 0.0 18

15 0.0 0.0 16

EXISTING PANEL C -

WB-33 (MAIL ROOM)

20 A 3

13 0.0 0.0 14

3 30 A NEW DC-2

11 0.0 0.0 12

9 0.0 0.0 10NEW PP-2 (P-1) 40 A 3

7 0.0 0.0 8

3 30 A NEW DC-1

5 0.0 0.0 6

3 0.0 0.0 4NEW PP-1 (P-1) 40 A 3

1 0.0 0.0 2

3 40 A NEW PP-2 (P-2)

LOAD DESCRIPTION BKR P CKT

PHASE A

kVA

PHASE B

kVA

PHASE C

kVA CKT P BKR LOAD DESCRIPTION

BUS AMPS: 400 AMPS

MAIN DEVICE: 400.0 A MAIN CB SPECIAL:

MOUNTING: SURFACE NEMA 1 A.I.C. RATING: 10,000 AMPS SYMMETRICAL

LOCATION: ELECTRICAL SWITCH... VOLTAGE: 208Y/120 V. 3 ø 4 W.

PANELBOARD: WB-H

AMBULATORY PENTHOUSE

CO2

CO

H

HS

NO2

S

TH

TS

T

MS

CHWS

CD

CW

F-CW

H-CW

S-CW

PD

V

SS

SD

OSD

(E)

CHWR CHILLED WATER RETURN

CHILLED WATER SUPPLY

CONDENSATE DRAINAGE

DOMESTIC COLD WATER

FILTERED COLD WATER

HARD COLD WATER

SOFT COLD WATER

PUMP DISCHARGE

SANITARY VENT

SANITARY SEWER

STORM DRAINAGE

OVERFLOW STORM DRAINAGE

REF-L

REF-S

REFRIGERANT-LIQUID

REFRIGERANT-SUCTION

2"

PLUMBING AND PIPING SYMBOLS

KEYNOTE

CONTINUATION SYMBOL

REVISION NUMBER - SHOWN ON PLANS

GENERAL MECHANICAL SYMBOLS

ROOM NAME AND NUMBER

POINT WHERE NEW CONNECTS TO EXISTING

EXISTING PIPE TAG

ITEM TO BE DEMOLISHED

AREA NOT IN CONTRACT

PIPING BEING DEMOLISHED

ABOVE GROUND PIPING

PIPE SIZE TAG (DIAMETER)

DRAIN SIZE

PIPE RISEPIPE DROP

BELOW GROUND PIPING

PIPE INVERT ELEVATION TAG

PIPE SLOPE TAG

* NOTE *

ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN

THIS SET.THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE

USED IN THIS SET OF DRAWINGS.

TYPE (SEE SCHEDULE)

Room

INVERT: -10' - 1"

1/8" / 12" SLOPE

RO REVERSE OSMOSIS WATER

16"x8"

16"/8"

(E)

F

S

M

B

D

C

16"Ø

E/A

O/A

T/A

L/A

R/A

S/A

EXHAUST AIR

OUTSIDE AIR

RELIEF AIR

RETURN AIR

SUPPLY AIR

TRANSFER AIR

GRILLES, REGISTERS & DIFFUSERS TAG

CFM

THROW-150FPM/ 100FPM/ 50FPM

NECK SIZE / MODULE SIZE

EXISTING DUCT TAG

OVAL DUCT SIZE TAG (WIDTH / HEIGHT)

SQUARE DUCT SIZE TAG (WIDTH x HEIGHT)

HVAC SYMBOLS

RECTANGULAR SUPPLY/OUTSIDE AIR DUCT RISE

RECTANGULAR RETURN/TRANSFER AIR DUCT RISE

MECHANICAL EQUIPMENT TAGS

ROUND DUCT SIZE TAG (DIAMETER)

LINEAR DIFFUSER TAG

CFM

TYPE (SEE SCHEDULE) NUMBER OF SLOTS /

ACTIVE SLOT LENGTH (PLENUM LENGTH) /

NECK SIZE

DUCT BEING DEMOLISHED

ELEVATION (CENTER OF FACE)

ROUND SUPPLY/OUTSIDE AIR DUCT RISE

ROUND RETURN/TRANSFER AIR DUCT RISE

RECTANGULAR EXHAUST/RELIEF AIR DUCT RISE

ROUND EXHAUST/RELIEF AIR DUCT RISE

DROP

DROP

DROP

DROP

DROP

DROP

GE/A GREASE EXHAUST AIR

SE/A SMOKE EXHAUST AIR

EQUIPMENT BY OTHERS

(REFER TO OTHER DISCIPLINE

FOR ADDITIONAL

INFORMATION)

EXISTING EQUIPMENT

TO REMAIN

FLUE EXHAUST GAS FLUE

C/A COMBUSTION AIR

S-O/A CONDITIONED OUTSIDE AIR

VAV-XX

10' - 0"

(E)VAV-XX

VAV-XX

4000 SF

6" SD-1

Ø ROUND

ABV ABOVE

AC AIR CONDITIONING

AD AREA DRAIN

ADD ADDENDUM

AFF ABOVE FINISHED FLOOR

AFUE ANNUAL FUEL UTILIZATION EFFICIENCY

ALT ALTERNATE

AP ACCESS PANEL

ARCH ARCHITECT/ARCHITECTURAL

BFF BELOW FINISHED FLOOR

BLW BELOW

BTU BRITISH THERMAL UNITS

BTUH BRITISH THERMAL UNITS PER HOUR

CAP CAPACITY

CB CATCH BASIN

CFM CUBIC FEET PER MINUTE

CLG CEILING

CO CLEAN OUT

CW COLD WATER

D DEGREE

DB DRY BULB

DIA DIAMETER

DN DOWN

DW DISTILLED WATER

EA EACH

EAT ENTERING AIR TEMPERATURE

ELEC ELECTRICAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

E/A EXHAUST AIR

EXIST EXISTING

F DEGREES FAHRENHEIT

FCO FLOOR CLEAN OUT

FD FLOOR DRAIN

FD FIRE DAMPER

FDV FIRE DEPARTMENT VALVE

FL FLOOR

FO FUEL OIL

FOV FUEL OIL VENT

FOR FUEL OIL RETURN

FOS FUEL OIL SUPPLY

FPM FEET PER MINUTE

FS FLOOR SINK

FT FOOT/FEET

FTR FIN TUBE RADIATION

GAL GALLON

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

GW GREASE WASTE

HB HOSE BIB

HP HORSE POWER

HTG HEATING

HTR HEATER

HW HOT WATER

HYD HYDRANT

ID INDIRECT

IN INCH

INV INVERT

LB POUND

LB/HR POUNDS PER HOUR

LAT LEAVING AIR TEMPERATURE

LP LOW PRESSURE

LPG LIQUEFIED PETROLEUM GAS

LVR LOUVER

LWT LEAVING WATER TEMPERATURE

M/A MIXED AIR

MAX MAXIMUM

MBH ONE THOUSAND BTU PER HOUR

MCF ONE THOUSAND CUBIC FEET

MD MOTORIZED DAMPER

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MTR MOTOR

MU/A MAKE-UP/AIR

NC NOISE CRITERIA

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NUMBER

NO NORMALLY OPEN

NTS NOT TO SCALE

O OXYGEN

O/A OUTSIDE AIR

P&T PRESSURE AND TEMPERATURE

PD PRESSURE DROP

PIV POST INDICATOR VALVE

PLBG PLUMBING

PRESS PRESSURE

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH GAUGE

PWR POWER

R DUCT RISER

R/A RETURN AIR

RCP RADIANT CEILING PANEL

RD ROOF DRAIN

REC RECESSED

RED REDUCER

RH RELATIVE HUMIDITY

RL/A RELIEF AIR

RM ROOM

RPM REVOLUTIONS PER MINUTE

RW RAIN WATER

SF SQUARE FOOT

S/A SUPPLY AIR

SAN SANITARY

SF SQUARE FOOT

SD SMOKE DAMPER

SM SURFACE MOUNT

SP STANDPIPE

SP STATIC PRESSURE

STM STEAM

T THERMOSTAT

TD TEMPERATURE DROP

TDR TRENCH DRAIN

TEMP TEMPERATURE

TYP TYPICAL

UG UNDERGROUND

VAC VACUUM

V VENT

VAV VARIABLE AIR VOLUME

VENT VENTILATION

VTR VENT THROUGH ROOF

W WASTE

WB WET BULB

WCO WALL CLEAN OUT

WH WALL HYDRANT

ABBREVIATIONS

AC AIR CONDITIONING UNIT

ACC AIR COOLED CONDENSER

ACCU AIR COOLING CONDENSING UNIT

AHU AIR HANDLING UNIT

AS AIR SEPARATOR

B BOILER

CH CHILLER

CT COOLING TOWER

CUH CABINET UNIT HEATER

CWP CONDENSER WATER PUMP

CHWP CHILLED WATER PUMP

CRAC COMPUTER ROOM AIR CONDITIONING UNIT

DBP DOMESTIC WATER BOOSTER PUMP

DC DUCT MOUNTED COIL

DCP DOMESTIC WATER CIRCULATING PUMP

EF EXHAUST FAN

EDC ELECTRIC DUCT COIL

ET EXPANSION TANK

EWH ELECTRIC WATER HEATER

FCU FAN COIL UNIT

FP FIRE PUMP

GI GREASE INTERCEPTOR

GRV GRAVITY ROOF VENTILATOR

HWP HEATING WATER PUMP

HX HEAT EXCHANGER

HRU HEAT RECOVERY UNIT

PRV POWER ROOF VENTILATOR

RE RETURN/EXHAUST FAN

RTU ROOFTOP UNIT

SEP SEWAGE EJECTOR PUMP

SF SUPPLY FAN

SP SUMP PUMP

UH UNIT HEATER

WH WATER HEATER

EQUIPMENT ABBREVIATIONS

48"x2 1/2"

400SLB3

8" / 24x24

300SD3

12" / ---

SD9

LINEAR BAR GRILLE

LINEAR SLOT DIFFUSER

PERFORATED DIFFUSER

WITH DEFLECTORS

ROUND DIFFUSER WITH

ADJUSTABLE PATTERNS

LOUVERED DOUBLE

DEFLECTION GRILLE

12"x10" / ---

500SG7

TYPE (SEE SCHEDULE)

10" / 24x24 H-5/7/1422

400SD1

3-CONE DIFFUSER

THROW PATTERN

MAX NC RATING

1 / 4' - 0" / 8"

200LSD1

8' - 0" AFF

1 / 4' - 0" / 8"

200LSD1

18' - 0"

1 / 4' - 0" / 8"

200LSD1

SECTION TOTAL TRACK LENGTH

12"x10" / 24x12

500RG9

LOUVERED GRILLE

12"x10" / 24x24

500RG2

EGGCRATE RETURN

GRILLE

BOTTOM OF EQUIPMENT

ELEVATION

505 lb

RTU-XX

RTU-XX

3.0 ton

115000 Btu/h

115 CFH

RTU-XX

Htg: 3.7 GPM

VAV-XX

HEATING COIL

FLOW

OPERATING WEIGHT

NOT INCLUDING CURB

FUEL INPUT

GAS PIPE FLOW

NOMINAL COOLING

CAPACITY

4" FD-1FLOOR DRAIN

VAV BOX

ROOFTOP UNIT

4" AD-6 AREA DRAIN

4" FS-4FLOOR SINK

4" SD-29 DECK DRAIN4" FD-3PFLOOR DRAIN

8 WFU

4" FD-13

HUB DRAIN

DRAIN TAGS

"P" - INDICATES

PRIMER CONNECTION

FIXTURE UNITS

FLOW CONTROL

DRAIN

4" SD-12

COMBINATION

DRAINS

STORM DRAIN4" SD-15

ROOF AREA

SERVED BY DRAIN

PIPE ACCESSORY TAGS

DOMESTIC WATER METER

BALANCING VALVE

1/4 TURN BALL VALVE

CHECK VALVE

3-WAY MIXING VALVE

MOTORIZED CONTROL VALVE

3 WAY MOTORIZED CONTROL

VALVE

PRESSURE REDUCING VALVE

REFRIGERANT SOLENOID VALVE

BUTTERFLY VALVE

DATA DEVICE TAGS

DAMPER TAGS

VAV-XX

RTU-XX

EQUIPMENT ID

SYMBOL

BBB

INLET COLLAR DAMPER

MANUAL BALANCING DAMPER

BACKDRAFT DAMPER

COMBINATION FIRE/SMOKE

DAMPER

FIRE DAMPER

SMOKE DAMPER

MOTORIZED DAMPER

SENSOR

MANUAL SWITCH

THERMOSTAT

TEMPERATURE SENSOR

TEMPERATURE & HUMIDITY SENSOR

HUMIDITY SENSOR

NITROGEN DIOXIDE SENSOR

CARBON MONOXIDE SENSOR

CARBON DIOXIDE SENSOR

HUMIDISTAT

WATER CLOSET -

WALL HUNG - ADA WC-1

U-1

1 WFU

LAV-1A

1.5 CWFU

1.5 HWFU

LAV-1A

FIXTURE UNITS

4" WCO

PIPE ACCESORY

TAG

PLUMBING FIXTURE TAGS

4" WCO

TYPE (SEE SCHEDULE)

WC-1A

NUMBER OF SHEET WHERE DETAIL APPEARS

NUMBER OF DETAIL ON SHEET-

(40% PROPYLENE GLYCOL)

(40% PROPYLENE GLYCOL)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseArchitect/Engineer of Record StampConsultant

321 4 5 6 7 8 9 10

Sprinkler Status

M001

HVAC SYMBOLS, ABBREVIATIONS

AND GENERAL NOTES209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

WWW.AE-WORKS.COM

AE WORKS PROJECT #: 18017

REPLACE IT HVAC HEAT

EXCHANGER

135 East 38th Street, Erie, PA 16504

562-18-401

05/10/2019 CJC CJC

100% CONSTRUCTION

DOCUMENTS

PROJECT GENERAL NOTES

* REMOVE ALL UNUSED PIPING, DUCTWORK AND ACCESSORIES.

* THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING, PRIOR TO FINAL BID, ALL

EXISTING CONDITIONS FOR PLUMBING AND MECHANICAL SYSTEMS WITHIN SPACE.

* THE CONTRACTOR SHALL VISIT THE SITE, PRIOR TO FINAL BIDDING, AND VERIFY ALL EXISTING

SITE CONDITIONS. PROVIDE ALL MATERIAL AND COMPONENTS AS NEEDED TO BRING THE

UNITS TO FULL COMPLIANCE OF THE VA’S REQUIREMENTS.

* WHERE FLOOR DRAINS OCCUR WITHIN THE LIMITS OF CONSTRUCTION, PREVENT

CONSTRUCTION DEBRIS FROM ENTERING DRAIN BODY BY SEALING DRAIN OPENING PRIOR TO

START OF WORK.

* COORDINATE INSTALLATION OF PIPING, DUCTWORK, CONDUIT, LIGHTS, CABLE TRAY,

STRUCTURE, AND EQUIPMENT TO PREVENT CONFLICTS.

* THE CONTRACTOR SHALL BE FAMILIAR WITH ALL THE CONDITIONS BOTH EXISTING AND THOSE

ILLUSTRATED BY THESE DOCUMENTS AS WELL AS THOSE WHICH CAN BE REASONABLY

ANTICIPATED INCLUDING, BUT NOT LIMITED TO ARCHITECTURAL, ELECTRICAL, VENTILATION, PLUMBING, AND OTHER SYSTEMS INVOLVED ON THIS PROJECT.

* FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM, AND SHALL CONFORM TO

ALL REQUIREMENTS OF APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING BUT NOT

LIMITED TO THE INTERNATIONAL BUILDING CODE AND INTERNATIONAL MECHANICAL CODE.

* LOCATE EQUIPMENT REQUIRING ACCESS 2'-0" MAXIMUM ABOVE CEILING.

* ALL ROOF MOUNTED EQUIPMENT SHALL BE A MINIMUM 10'-0" FROM EDGE OF ROOF.

* LOCATE DUCTWORK, PIPING AND MECHANICAL EQUIPMENT AWAY FROM THE SPACE ABOVE

ELECTRICAL PANELS. TRANSFORMERS AND OTHER ELECTRICAL EQUIPMENT.

* FIRE SEAL AROUND DUCT AND PIPING PENETRATIONS OF FIRE RATED WALLS. REFER TO

SPECIFICATION.

* PROVIDE SLEEVES AND/OR OPENINGS TO RUN PIPES AND DUCTS THROUGH FOUNDATIONS,

FLOORS, WALLS, AND ROOF.

* ADJUST PIPING AND DUCTWORK SIZES TO PROPERLY CONNECT TO MECHANICAL EQUIPMENT.

* REFER TO PLUMBING SERIES DRAWINGS FOR GAS AND A.C. CONDENSATE DRAIN PIPING.

* PIPE SIZES SHOWN SHALL BE CONTINUED IN THE DIRECTION OF FLOW UNTIL ANOTHER SIZE IS

SHOWN.

* FOR DETAILS, EQUIPMENT CONNECTIONS, AND PIPE SIZES NOT SHOWN ON THE SEGMENTS,

REFER TO DETAILS, SCHEDULES, AND SPECIFICATIONS.

* INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE RESPECTIVE MANUFACTURER'S WRITTEN

INSTALLATION INSTRUCTIONS, AT A LEVEL OF QUALITY AND WORKMANSHIP CONSISTENT WITH

THE SPECIFICATIONS.

* LOCATIONS OF PIPING, DUCTWORK AND EQUIPMENT AS INDICATED ON THE DRAWING, ARE

APPROXIMATE AND SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD. WORK SHALL BE

COORDINATED WITH ALL OTHER TRADES TO AVOID INTERFERENCE IN THE FIELD.

* INSTALL EXPOSED PIPING AND DUCTWORK AS HIGH AS PRACTICAL IN ROOMS WITHOUT

CEILINGS.

HVAC PROJECT GENERAL NOTES

1 NOT ALL SYMBOLS ARE NECESSARILY USED.

2 COORDINATE FINAL LOCATIONS OF DIFFUSERS AND GRILLES WITH ARCHITECTURAL REFLECTED

CEILING PLANS.

3 DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO FIELD VERIFY DUCT AND PIPE ROUTING AND

COORDINATE INTERFERENCE BETWEEN TRADES PRIOR TO INSTALLATION.

4 REMOVE ALL UNUSED PIPING, DUCTWORK AND ACCESSORIES.

5 DUCTWORK TO BE INSTALLED TIGHT TO UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED

OTHERWISE.

6 PROVIDE ALL MATERIALS, EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL

COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS

SPECIFIED AND AS REQUIRED BY CODE.

7 CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK ARE DIAGRAMMATIC AND ARE

INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. CONTRACTOR SHALL BE

RESPONSIBLE TO FIELD SURVEY ACTUAL SITE CONDITIONS AND ACCOMODATE ACTUAL SITE

CONDITIONS AS PART OF SCOPE OF WORK AT NO COST TO OWNER.

8 INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATIONS, CONTRACT DOCUMENTS, APPLICABLE BUILDING, STATE

AND LOCAL CODES, SEISMIC REQUIREMENTS, ENERGY CODES AND INSURANCE UNDERWRITER

REQUIREMENTS.

9 COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL,

CIVIL AND ELECTRICAL WORK, ETC. SHOWN ON OTHER CONTRACT DOCUMENT DRAWINGS.

10 MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF PIPES, DUCTS, CONDUITS,

SUSPENDED EQUIPMENT, SUPPORTS, ETC., THROUGHOUT ACCESS ROUTES IN MECHANICAL

ROOMS.

11 ALL TESTS SHALL BE COMPLETED AND ACCEPTED BY THE INSPECTOR BEFORE ANY

MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED.

12 LOCATE ALL TEMPERATURE, PRESSURE AND FLOW MEASURING DEVICES IN ACCESSIBLE

LOCATIONS WITH STRAIGHT SECTION OF PIPE OR DUCT UPSTREAM AND DOWNSTREAM, AS

RECOMMENDED BY THE MANUFACTURER FOR ACCURACY.

13 TESTING ADJUSTING AND BALANCING (TAB) AGENCY SHALL BE A MEMBER OF THE ASSOCIATED

AIR BALANCING COUNCIL (AABC) OR THE NATIONAL ENVIRONMENTAL BALANCING BUREAU

(NEBB). TAB FIRM SHALL HAVE A MINIMUM OF 5 YEARS EXPERIENCE ON SIMILAR PROJECTS.

PERFORM TAB IN ACCORDANCE WITH THE REQUIREMENTS OF THE TAB PROCEDURAL

STANDARD RECOMMENDED BY THE TAB TRADE ASSOCIATION THAT APPROVED THE TAB FIRM'S

QUALIFICATIONS.

14 WHERE TWO OR MORE ITEMS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE

PRODUCTS OF A SINGLE MANUFACTURER SHALL BE USED.

15 COORDINATE ALL FINAL EQUIPMENT CONNECTIONS WITH THE MANUFACTURERS' CERTIFIED

DRAWINGS. COORDINATE AND PROVIDE ALL DUCTWORK AND PIPING TRANSITIONS REQUIRED

FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND

COORDINATE ALL DUCTWORK AND PIPING DIMENSIONS BEFORE FABRICATION.

16 ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE,

DIVISION 26 OF THE SPECIFICATIONS, ALL LOCAL CODES, AND OWNER'S INSURANCE

UNDERWRITER REQUIREMENTS.

17 THE LOCATIONS AND SIZES OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE

SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY.

THE EXACT LOCATIONS AND SIZES NECESSARY TO SECURE THE BEST CONDITIONS AND

RESULTS SHALL BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE

APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS.

18 PLAN DRAWINGS AND SECTIONS CUTS WHICH SPECIFICALLY IDENTIFY SERVICE ROUTE

OFFSETS, ELEVATION CHANGES, OBSTRUCTIONS, ACCESS DOORS, BALANCING DEVICES, ETC.

ARE SHOWN FOR CLARITY WHERE SPECIFIC KNOWN CONDITIONS EXIST. MECHANICAL

CONTRACTOR SHALL COORDINATE EQUIPMENT, DUCTWORK, AND PIPING ROUTINGS WITH ALL

OTHER TRADES. REQUIREMENTS NOT SPECIFICALLY IDENTIFIED SHALL NOT BE INTERPRETED

AS EXCLUSION FROM CONTRACTOR'S SCOPE OF WORK. CONTRACTOR SHALL BE RESPONSIBLE

FOR ACTUAL SITE CONDITIONS AND SHALL INCLUDE SUCH CONDITIONS IN SCOPE OF WORK AT

NO ADDITIONAL COST TO THE OWNER.

19 ALL MISCELLANEOUS STEEL REQUIRED TO ENSURE PROPER INSTALLATION AND SUPPORT OF

MECHANICAL WORK AS SHOWN IN DETAILS FOR PIPING, DUCTWORK AND EQUIPMENT (UNLESS

OTHERWISE NOTED) SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR

AT NO ADDITIONAL COST TO THE OWNER.

20 ALL EQUIPMENT, PIPING, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED, SPECIFIED AND

AS REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION.

21 ALL OPENINGS IN FIRE RATED WALLS AND SMOKE PARTITIONS DUE TO DUCTWORK, PIPING, CONDUIT, ETC., SHALL BE FIRE STOPPED WITH APPROVED FIRESTOPPING MATERIALS.

22 REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING AND EQUIPMENT INSTALLATION.

23 WHERE FLOOR DRAINS OCCUR WITHIN THE LIMITS OF CONSTRUCTION, PREVENT

CONSTRUCTION DEBRIS FROM ENTERING DRAIN BODY BY SEALING DRAIN OPENING PRIOR TO

START OF WORK.

24 LOCATE ALL MECHANICAL EQUIPMENT (VAV BOXES, CABINET HEATERS, UNIT HEATERS, ETC.,)

FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS, FILTERS, CONTROLS AND VALVING. DO

NOT LOCATE FAN POWERED VAV BOXES ABOVE LIGHTING FIXTURES.

25 FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM, AND SHALL CONFORM TO ALL REQUIREMENTS OF APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING BUT NOT

LIMITED TO THE INTERNATIONAL BUILDING CODE AND INTERNATIONAL MECHANICAL CODE.

26 LOCATE DUCTWORK, PIPING AND MECHANICAL EQUIPMENT AWAY FROM THE SPACE ABOVE

ELECTRICAL PANELS. TRANSFORMERS AND OTHER ELECTRICAL EQUIPMENT.

27 PROVIDE AN AIR VENT AT THE HIGH POINT OF EACH DROP IN HYDRONIC WATER PIPING

SYSTEMS. ALL PIPING SHALL SLOPE TO LOW POINTS. PROVIDE HOSE END DRAIN VALVES AT THE

BOTTOM OF ALL RISERS AND LOW POINTS.

28 INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES AND OTHER

APPURTENANCES REQUIRING ACCESS ARE ACCESSIBLE.

29 ALL ISOLATION VALVES SHALL BE IN LOCATION AND ELEVATION WHICH ALLOWS FOR EQUIPMENT

AND BRANCH PIPING REMOVAL, WHILE MAINTAINING SERVICE UPSTREAM OF THE ISOLATION

VALVE.

30 ALL BALANCING VALVES AND ISOLATION VALVES USED TO ADJUST FLOW RATES SHALL BE

PROVIDED WITH POSITIONS INDICATORS AND MAXIMUM ADJUSTABLE STOPS (MEMORY STOPS).

31 ALL ISOLATION VALVES (EXCEPT CONTROL VALVES), STRAINERS, AND PIPING SPECIALTIES SHALL BE FULL LINE SIZE BEFORE REDUCING SIZE TO MAKE CONNECTIONS TO EQUIPMENT AND

CONTROLS.

32 MECHANICAL JOINTS SUCH AS UNIONS, FLANGES, OR THREADED FITTINGS SHALL BE INSTALLED

AT EACH EQUIPMENT CONNECTION, IN BYPASSES, AT FLOOR PENETRATIONS, AT CONTROL

DEVICES, AND IN LONG PIPE RUNS (100 FEET OR MORE) TO PERMIT DISASSEMBLY FOR

ALTERATION AND REPAIRS.

33 MEASURE, CUT AND INSTALL PIPE LENGTH ACCURATELY TO MINIMALIZE MISALIGNMENT.

INSTALL ALL PIPING WITHOUT FORCING OR SPRINGING.

34 PROVIDE FLEXIBLE CONNECTIONS IN ALL PIPING SYSTEMS CONNECTED TO PUMPS AND OTHER

EQUIPMENT WHICH REQUIRE VIBRATION ISOLATION (EXCEPT WATER COILS). FLEXIBLE

CONNECTIONS SHALL BE PROVIDED AS CLOSE TO THE EQUIPMENT AS POSSIBLE OR AS

INDICATED ON THE DRAWINGS.

35 PROVIDE VIBRATION INSULATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT VIBRATION

TRANSMISSION TO BUILDING STRUCTURE.

36 FIRE SEAL AROUND DUCT AND PIPING PENETRATIONS OF FIRE RATED WALLS. REFER TO

SPECIFICATION.

37 ALL DUCTWORK, PIPING, AND EQUIPMENT SUPPORTED FROM STRUCTURAL STEEL SHALL BE

COORDINATED WITH GENERAL CONTRACTOR. ALL ATTACHEMENTS TO STEEL MEMBERS, BAR

JOISTS, TRUSSES, OR JOIST GIRDERS SHALL BE APPROVED BY STRUCTURAL ENGINEER.

WELDING TO STRUCTURAL MEMBERS SHALL NOT BE PERMITTED.

38 MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING SHALL NOT BE SUPPORTED FROM ROOF OR

DECK ASSEMBLY. SUPPORTS SHALL ATTACH TO STRUCTURAL MEMBERS. COORDINATE WITH

STRUCTURAL DRAWINGS.

39 PROVIDE SLEEVES AND/OR OPENINGS TO RUN PIPES AND DUCTS THROUGH FOUNDATIONS,

FLOORS, WALLS, AND ROOF.

40 UNLESS OTHERWISE NOTED, ALL PIPING AND DUCTWORK IF OVERHEAD, TIGHT TO UNDERSIDE

OF STRUCTURE OR SLAB, WITH SPACE FOR INSULATION.

41 PROVIDE CHAINWHEEL OPERATORS FOR ALL EXPOSED VALVES MOUNTED GREATER THAN 8'-0"

ABOVE FINISHED FLOOR LEVEL. CHAIN SHALL EXTEND UNOBSTRUCTED TO 7'-0" ABOVE FLOOR

LEVEL.

42 ALL PIPING AND DUCTWORK SHALL CLEAR DOORS, WINDOWS, EQUIPMENT CLEARANCES,

MAINTENANCE REQUIREMENTS, CODE SETBACKS, ETC. TO ASSURE PROPER OPERATION,

INSPECTION AND MAINTENANCE.

43 ALL VALVES SHALL BE ADJUSTED FOR SMOOTH AND EASY OPERATION.

44 PROVIDE ALL 90 DEGREE SQUARE ELBOWS WITH DOUBLE RADIUS TURNING VANES UNLESS

OTHERWISE INDICATED OR SPECIFIED. PROVIDE ACCESS DOORS UPSTREAM OF ALL ELBOWS

CONTAINING TURNING VANES.

45 ADJUST PIPING AND DUCTWORK SIZES TO PROPERLY CONNECT TO…