36A79720Q0003-052.pdf

PDF Posted

Attached to
September 2019 Consolidation
Solicitation number
36A79720Q0003
Issued by

About this file

36A79720Q0003 636B94052 - XR MAMMO, VAMC IOWA CITY, IA redacted.pdf

View the file

Other files

File Type Posted
36A79720Q0003-0002000.docx DOCX document
36A79720Q0003-0002001.zip ZIP file
36A79720Q0003-0001357.zip ZIP file
36A79720Q0003-0001380.zip ZIP file
36A79720Q0003-0001375.zip ZIP file
36A79720Q0003-0001353.pdf PDF
36A79720Q0003-0001359.zip ZIP file
36A79720Q0003-0001354.xlsx XLSX spreadsheet
36A79720Q0003-0001374.zip ZIP file
36A79720Q0003-0001369.zip ZIP file
36A79720Q0003-0001386.zip ZIP file
36A79720Q0003-0001372.zip ZIP file
36A79720Q0003-0001373.zip ZIP file
36A79720Q0003-0001360.zip ZIP file
36A79720Q0003-0001385.zip ZIP file
36A79720Q0003-0001368.zip ZIP file
36A79720Q0003-0001377.zip ZIP file
36A79720Q0003-0001352.pdf PDF
36A79720Q0003-0001378.zip ZIP file
36A79720Q0003-0001361.zip ZIP file
36A79720Q0003-0001366.zip ZIP file
36A79720Q0003-0001388.zip ZIP file
36A79720Q0003-0001371.zip ZIP file
36A79720Q0003-0001387.zip ZIP file
36A79720Q0003-0001367.zip ZIP file
36A79720Q0003-0001389.zip ZIP file
36A79720Q0003-0001362.zip ZIP file
36A79720Q0003-0001351.docx DOCX document
36A79720Q0003-0001376.zip ZIP file
36A79720Q0003-0001379.zip ZIP file
36A79720Q0003-0001363.zip ZIP file
36A79720Q0003-0001382.zip ZIP file
36A79720Q0003-0001358.zip ZIP file
36A79720Q0003-0001384.zip ZIP file
36A79720Q0003-0001364.zip ZIP file
36A79720Q0003-0001383.zip ZIP file
36A79720Q0003-0001381.zip ZIP file
36A79720Q0003-0001370.zip ZIP file
36A79720Q0003-0001356.zip ZIP file
36A79720Q0003-0001365.zip ZIP file
36A79720Q0003-0001355.zip ZIP file
36A79720Q0003-042.zip ZIP file
36A79720Q0003-047.zip ZIP file
36A79720Q0003-057.zip ZIP file
36A79720Q0003-060.zip ZIP file
36A79720Q0003-064.zip ZIP file
36A79720Q0003-017.pdf PDF
36A79720Q0003-009.zip ZIP file
36A79720Q0003-005.pdf PDF
36A79720Q0003-058.zip ZIP file
Show 40 more

Latest 50 of 180 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Functional Requirements for Mammography Biopsy Specimen Imaging for Iowa City VA Healthcare System (Station 636A8)

Requisition Number 636-B94052

This imaging device will be used in the Mammography suite to assist in confirming successful biopsies.

Technical Requirements:

1. Minimum monitor size of 24 inches

2. Minimum monitor resolution of 3.7 MP

3. Automatic Exposure Control

4. Minimum detector size 10cm x 15cm

5. Detector resolution at least 10 lp/mm

6. Battery backup able to last at least 2 hours

7. Automatic Calibration

8. DICOM compliant

9. Transparent Imaging Door

Support and other Documentation to Provide:

1. Provide DICOM Conformance Statement

2. Provide completed Pre-procurement Assessment form (6550)

3. Provide information about your companies support structure during the warranty period (i.e. a listing of Field Service Engineer locations and availability, support 800 phone number(s), remote support, etc.). Warranty Period shall be a minimum of 1 year – part and labor. Contractor shall provide a hard copy of the warranty with the product.

4. Provide 2 Copies Product Service Manuals (1 Hard Copy and 1 Digital Copy)

Training

1. On-site

a. Clinical applications – minimum of 1 days (4 hours each day)

b. Training should include both technologists and physicians

Trade-in

NONE

Product Name Long Description BIOVISION10X15 Faxitron BioVision 10x15 Digital Surgical Biopsy Specimen Imaging System includes 10cm x 15cm digital detector, 48?m, 10 lp/mm Contact Mode High resolution 3.7 MP flat-panel LCD monitor Ergonomic Keyboard, Transparent Imaging Door, 3 Hour Battery Backup Operation, Battery Life Indicator, Automatic Exposure, Automatic Calibration Includes one year manufacturer warranty Quote