36A77620Q0076-009.pdf
PDF Posted
- Solicitation number
- 36A77620Q0076
About this file
This document contains a federal solicitation for patient lift equipment and installation services. The Veterans Affairs Nebraska-Western Iowa Healthcare System requires overhead patient lifts for various clinical areas in its new Ambulatory Care Center in Omaha, Nebraska. The solicitation will be issued as a Request for Quote on or about February 13, 2020, seeking a single-award, firm-fixed price contract. Offerors must submit quotes electronically by the closing date specified in the RFQ. The Hill-Rom Liko Lift is the basis of design, and the applicable NAICS code is 339113 with a size standard of 750 employees. The statement of work details the required equipment, delivery, and installation services.
36A77620Q0076 S02 - ATTACHMENT 5 - Unistrut Support Shop Drawings - Patient Lift Equip.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36A77620Q0076-0001001.docx | DOCX document | |
| 36A77620Q0076-0001000.docx | DOCX document | |
| 36A77620Q0076-006.pdf | ||
| 36A77620Q0076-010.xlsx | XLSX spreadsheet | |
| 36A77620Q0076-011.pdf | ||
| 36A77620Q0076-008.pdf | ||
| 36A77620Q0076-007.pdf | ||
| 36A77620Q0076-004.docx | DOCX document | |
| 36A77620Q0076-005.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Unistrut to Beam/Vertical from Unistrut to Deck
Installed per documents
Pendant to Unistrut (Vendor furnished and Installed)
Future Vendor to Furnish and Install
SWAY BRACES
Option 1: The Sway Bracing material (Uni-Strut) that is currently shown to be installed can be turned over to the VA for future installation by the successful patient lift provider/vendor.
The VA will need to store the material until the patient lift provider has been selected and has installed the lift pendant to the uni-strut.
Once the lift pendant is installed the patient lift provider would need to install the sway bracing. Please note, the uni-strut amounts to approximately 100 pieces which are 20’ in length.
These pieces would need to be stored by the VA until the patient lift provider was ready to install.
Option 2: The VA can procure the furnish and install of the sway bracing during the patient lift procurement process. Utilizing this option would eliminate the handling, storage and transfer of the 100 pieces of 20’ long uni-strut.
Future Vendor to Furnish and Install
Option 1:Material to be turned over to the VA Option 2: Furnished and installed by future vendor
HARDLID CEILING
Installed per documents
This room was modified in RFI 423 to have a "horseshoe" styled support due to coordination clashes
Future Vendor to Furnish and Install
Installed per documents
6'-8"
Installed per documents
2'-0"
1' -1
Future Vendor to Furnish and Install
Installed per documents
Installed per documents
Installed per documents
Installed per documents
File details come from the government source that posted it. Updated .