260623_-_TARTA_10_-_Bid_Set_1_of_1.pdf

PDF 29 MB Posted

Attached to
TARTA Central Apron Fencing Project
Solicitation number
2026-REQ-060
Issued by
Lucas County, Ohio

About this file

This is a bid set of architectural, civil, structural, landscape, and electrical construction drawings for the Toledo Area Regional Transit Authority (TARTA) Central Avenue Garage Site Improvements project located at 1127 Central Avenue, Toledo, Ohio. The project involves comprehensive site improvements including pavement and grading work, traffic control for crosswalk improvements, landscape enhancements with new tree and shrub plantings, a new bus shelter structure, gate specifications, and electrical infrastructure. The bid set includes base bid and alternate bid options for pavement improvements, with detailed plans for demolition, site preparation, grading, and landscape design featuring the installation of shade trees, ornamental shrubs, and groundcover plantings. The architectural scope encompasses a new bus shelter with composite metal panels, aluminum curtain walls, skylights, and LED signage. Structural work includes a reinforced concrete slab-on-grade foundation with steel framing for the shelter structure and architectural exposed structural steel (AESS Level 4) design requirements. The electrical work provides power to new light pole fixtures, wall-mounted lights, gates, control systems, and the bus shelter with provision for 277-volt branch circuits and weatherproof receptacles.

The project team includes Richard L. Bowen & Associates Inc. as architect, DGL Consulting Engineers LLC as civil engineer, HEAPY as electrical engineer, and EDGE as landscape architect. The drawings are dated June 16, 2026 for the bid and permit set, with a 100 percent construction documents set dated June 5, 2026. Design specifications require all construction to conform to current International Building Code, Ohio Building Code, ACI 318, AISC 360, and AISI standards. Structural steel is specified as ASTM A500 Grade B tubes with ASTM A36 rolled angles and plates. Concrete slabs on grade require 4,000 PSI with 6 percent maximum air entrainment. The project notes indicate a requirement for a project labor agreement (PLA) and specifies that contractors must verify existing conditions, locate all utilities prior to work commencement, and follow manufacturer installation procedures. No soils report was prepared; designs are based on minimum Ohio Building Code requirements with footings and slabs bearing on competent native soil or approved engineered fill with a design net allowable bearing pressure of 1,500 PSF.

View the file

Other files

File Type Posted
260623_-_TARTA_10_-_Manual_1_of_1.pdf PDF
Declaration_of_Non-Collusion_SH.pdf PDF
Lobbying_Certifcation_.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TARTA - TOLEDO AREA REGIONAL TRANSIT AUTHORITY

1127 CENTRAL AVE

TOLEDO, OH 43610

Contact Person: Rick Bailey

RICHARD L. BOWEN & ASSOCIATES INC.

2019 CENTER STREET, SUITE 500

CLEVELAND, OHIO 44113

216.491.9300 (PH)

Contact Person: Ken Emling

ARCHITECT

OWNER

ELECTRICAL ENGINEER

HEAPY

1422 EUCLID AVE, SUITE 1162

CLEVELAND, OHIO 44115

216.862.5846 (PH)

Contact Person: Tim Krzywicki

CIVIL ENGINEER

DGL Consulting Engineers, LLC 6060 Rockside Woods Blvd N, Suite 215

INDEPENDENCE, OHIO 44131

440.387.4113 (PH)

Contact Person: Kyle Layton

EDGE

33 SOUTH MICHIGAN STREET, SUITE 100

TOLEDO, OHIO 43604

419.255.5335 (PH)

Contact Person: Tim Bockbrader

LANDSCAPE ARCHITECT

1. ALL EXISTING CONDITIONS TO BE VERIFIED PRIOR TO COMMENCEMENT OF WORK. IN

THE EVENT OF ANY DISCREPANCIES, REPORT SAID ANOMALIES TO THE ARCHITECT.

2. LOCATE ALL EXISTING UTILITIES AND SERVICES PRIOR TO START OF WORK.

3. ADHERE TO ALL ACCEPTED INDUSTRY PRACTICES.

4. FOLLOW ALL INSTALLATION PROCEDURES PER MANUFACTURER'S INSTRUCTIONS.

5. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT FOR ALL DIMENSION QUESTIONS.

6. DIMENSIONS ARE FROM THE FACE OF MASONRY FOR MASONRY WALLS, U.N.O.

7. FOR GYPSUM WALLS, DIMENSIONS ARE TO FACE OF GYPSUM BOARD, U.N.O.

8. FOR EXISTING WALLS, DIMENSIONS ARE TO EXISTING WALL FACE, U.N.O.

9. DIMENSIONS WITH “HOLD, MIN, MAX, CLEAR” ARE TO FINISHED FACE, U.N.O.

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

RLB NO.:

CHECKED BY:

DRAWN BY:

Description

C en te r

S t, S ui te

C le ve la nd

O hi o

P ho ne

(2

1-

F ax

6)

-8 w w w .r lb a.

co m

© RICHARD L. BOWEN + ASSOCIATES, INC.

6/

/2

2:

:1

P

M A ut od es k

D oc s:

//T

A R

T A

C en tr al A ve G ar ag e S ite Im pr ov em en ts /A

R C

H _T

A R

T A

-C en tr al

A ve

G ar ag e

S ite

_1

-1

0.

rv t

C en tr al

A ve nu e

G ar ag e

S ite

Im pr ov em en ts

13828.10

C en tr al

A ve

T ol ed o, O

H

C O

V E

R S

H E

E T

TLR

KJE

CS

Central Avenue Garage Site Improvements 6/16/2026

1127 Central Ave., Toledo, OH 43610BID SET

DRAWING INDEX

NUMBER NAME

GENERAL

CS COVER SHEET

CIVIL

C0.1 CIVIL NOTES

CD1.1 DEMOLITION PLAN - PAVEMENT IMPROVEMENTS

C1.1 SITE PLAN - PAVEMENT IMPROVEMENTS - BASE BID

C1.2 SITE PLAN - PAVEMENT IMPROVEMENTS - ALTERNATE BID

C2.1 GRADING PLAN - PAVEMENT IMPROVEMENTS - BASE BID

C2.2 GRADING PLAN - PAVEMENT IMPROVEMENTS - ALTERNATE BID

C2.10 TRAFFIC CONTROL - CROSSWALK IMPROVEMENTS

C5.0 GATE SPECIFICATIONS

LANDSCAPE

L1.1 LANDSCAPE PLAN

ARCHITECTURAL

A1.1 BUS SHELTER PLANS

A3.1 BUS SHELTER ELEVATIONS

A5.1 BUS SHELTER SECTIONS

A5.2 BUS SHELTER DETAILS

STRUCTURAL

S0.1 STRUCTURAL NOTES & SPECIFICATIONS

S1.1 FOUNDATION PLAN & DETAILS

S1.2 STRUCTURAL FRAMING PLAN & DETAILS

ELECTRICAL

E001 ELECTRICAL ABBREVIATIONS, SYMBOLS, LEGENDS, NOTES

ES100 ELECTRICAL SITE PLAN

E002 ELECTRICAL SINGLE LINE, PANEL SCHEDULES & DETAILS

E003 ELECTRICAL LIGHTING SCHEDULES & DETAILS

GENERAL PROJECT NOTES INDEX OF DRAWINGS

SITE LOCATION MAP

PROJECT TEAM

PROJECT SITE

06/05/26 100% CONST. DOCS

6/16/26 BID & PERMIT SET

BID & PERMIT SET

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

CE

NT

RA

L A

VE

NU

E, TO

LE

DO

, O H 4

LU

CA

S C

OU

NT

Y

CIV

IL

NO

TE

S

JL

KWL

C0.1

Ju n 1

8, 9:0 3a m Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

CI

VI

L\D wg

\24

7-

C D.

dw g:

C0 .1

NO

TE

S

TA

RT

A

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

GENERAL NOTES

EARTHWORK

GENERAL UTILITY NOTES

STORM SEWERS

STRUCTURAL CONCRETE

MANUFACTURED INLET FILTER INLET FILTER SPECIFICATIONS

MECHANICAL

PROPERTIES

TEST

METHOD MARV

SECTION

SEEDING AND MULCHING

CONCRETE PAVEMENT SECTION

ASHPHALT PAVEMENT SECTION

REINFORCED CONCRETE SECTION

CONCRETE SIDEWALK SECTION

STA

TE OF OHIO

PROFESS IONAL ENG

I N

EE

R

JOSHUA

LAU

E-87832

EG I S T ERED

R

June 16, 2026

CONCRETE PAVEMENT CONSTRUCTION JOINT

06.05.261 CD Set

06.16.262 Bid & Permit

S.B.M #1

DGL CP#501

DGL CP#300

DGL CP#503

TOLEDO AREA REGIONAL TRANSIT AUTHORITY

18-39847

VOL. 2002, PG 598

14.903 ACRES

CENTRAL AVENUE

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

CE

NT

RA

L A

VE

NU

E, TO

LE

DO

, O H 4

LU

CA

S C

OU

NT

Y

DE

MO

LIT

ION

PL

AN

- P

AV

EM

EN

T I

MP

RO

VE

ME

NT

S

JL

KWL

CD1.1

Ju n 1

8, 9:0 3a m Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

CI

VI

L\D wg

\24

7-

C D.

dw g:

CD

1.1

D

EM

O

TA

RT

A

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

0 10 20

SCALE: 1" = 10'

STA

TE OF OHIO

PROFESS IONAL ENG

I N

EE

R

JOSHUA

LAU

E-87832

EG I S T ERED

R

June 16, 2026

GATE

DGL CP#501

DGL CP#300

DGL CP#503

Δ

Δ

Δ

Δ

Δ Δ

Δ

Δ

Δ

Line Table Curve Table

TOLEDO AREA REGIONAL TRANSIT AUTHORITY

18-39847

VOL. 2002, PG 598

14.903 ACRES

CENTRAL AVENUE

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

CE

NT

RA

L A

VE

NU

E, TO

LE

DO

, O H 4

LU

CA

S C

OU

NT

Y

SIT

E P

LA

N -

PA

VE

ME

NT

IM

PR

OV

EM

EN

TS

- B

AS

E B

ID

JL

KWL

C1.1

Ju n 1

8, 9:0 3a m Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

CI

VI

L\D wg

\24

7-

C D

Ba se

.dw g:

C1 .1

PL

AN

T

AR

TA

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

0 10 20

SCALE: 1" = 10'

STA

TE OF OHIO

PROFESS IONAL ENG

I N

EE

R

JOSHUA

LAU

E-87832

EG I S T ERED

R

June 16, 2026

GATE

DGL CP#501

DGL CP#300

DGL CP#503

Δ

Δ

Δ

Δ

Δ Δ

Δ

Δ

Δ

TOLEDO AREA REGIONAL TRANSIT AUTHORITY

18-39847

VOL. 2002, PG 598

14.903 ACRES

CENTRAL AVENUE

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

CE

NT

RA

L A

VE

NU

E, TO

LE

DO

, O H 4

LU

CA

S C

OU

NT

Y

SIT

E P

LA

N -

PA

VE

ME

NT

IM

PR

OV

EM

EN

TS

- A

LT

ER

NA

TE

BI

D

JL

KWL

C1.2

Ju n 2

3, 8:5 1a m Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

CI

VI

L\D wg

\24

7-

C D.

dw g:

C1 .2

PL

AN

T

AR

TA

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

0 10 20

SCALE: 1" = 10'

STA

TE OF OHIO

PROFESS IONAL ENG

I N

EE

R

JOSHUA

LAU

E-87832

EG I S T ERED

R

June 16, 2026

TOLEDO AREA REGIONAL TRANSIT AUTHORITY

18-39847

VOL. 2002, PG 598

14.903 ACRES

CENTRAL AVENUE

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

CE

NT

RA

L A

VE

NU

E, TO

LE

DO

, O H 4

LU

CA

S C

OU

NT

Y

GR

AD

ING

PL

AN

- P

AV

EM

EN

T I

MP

RO

VE

ME

NT

S -

BA

SE

BI

D

JL

KWL

C2.1

Ju n 1

8, 9:0 3a m Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

CI

VI

L\D wg

\24

7-

G R

Ba se

.dw g:

C2 .1

GR

AD

T

AR

TA

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

0 10 20

SCALE: 1" = 10'

STA

TE OF OHIO

PROFESS IONAL ENG

I N

EE

R

JOSHUA

LAU

E-87832

EG I S T ERED

R

June 16, 2026

TOLEDO AREA REGIONAL TRANSIT AUTHORITY

18-39847

VOL. 2002, PG 598

14.903 ACRES

CENTRAL AVENUE

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

CE

NT

RA

L A

VE

NU

E, TO

LE

DO

, O H 4

LU

CA

S C

OU

NT

Y

GR

AD

ING

PL

AN

- P

AV

EM

EN

T I

MP

RO

VE

ME

NT

S -

AL

TE

RN

AT

E B

ID

JL

KWL

C2.2

Ju n 2

3, 8:5 6a m Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

CI

VI

L\D wg

\24

7-

G R.

dw g:

C2 .2

GR

AD

T

AR

TA

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

0 10 20

SCALE: 1" = 10'

STA

TE OF OHIO

PROFESS IONAL ENG

I N

EE

R

JOSHUA

LAU

E-87832

EG I S T ERED

R

June 16, 2026

CENTRAL AVENUE

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

CE

NT

RA

L A

VE

NU

E, TO

LE

DO

, O H 4

LU

CA

S C

OU

NT

Y

TR

AF

FIC

CO

NT

RO

L P

LA

N -

CR

OS

SW

AL

K I

MP

RO

VE

ME

NT

S

CMS

CML

C2.10

Ju n 1

5, :53 am Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

TR

AF

FI

C\

Dw g\2

-1 0 C

D_ Tr aff ic

Co ntr ol.

dw g:

C2

.10 T

RA

FF

IC

TA

RT

A

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

0 20 40

SCALE: 1" = 20'

06.05.261 CD Set

2 BID & PERMIT06.16.26

CML

Image

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

CE

NT

RA

L A

VE

NU

E, TO

LE

DO

, O H 4

LU

CA

S C

OU

NT

Y

GA

TE

SP

EC

IFI

CA

TIO

NS

JL

KWL

C5.0

Ju n 1

8, 9:0 4a m Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

CI

VI

L\D wg

\24

7-

C D.

dw g:

C5 .0

GA

TE

T

AR

TA

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

STA

TE OF OHIO

PROFESS IONAL ENG

I N

EE

R

JOSHUA

LAU

E-87832

EG I S T ERED

R

June 16, 2026

RETAINING WALL

LAWN

LAWN

LAWN

REPAIR LAWN

REPAIR LAWN

EXISTING PLANTING TO REMAIN

REPLACE 2 EXISTING TREES

WITH (3) SHADE TREES

CENTRAL AVE

TARTA BUS GARAGE

LAWN LAWN

LAWN

PARKING

PARKING

INOUT

BUS SHELTER

DEMO PORTION OF

WALK (CIVIL DEMO

PLANS)

REMOVE STUMP

UH

DS

AG

DS

DS

AG

PVS

JP

JP

HB

LAWN

LIMIT OF WORK

LI

M

IT

O

F W

O

RK

LAWN

4 4

BUS SHELTER

JP

EXISTING PAVED PADS

PREPERATION AREA - PLAN VIEW

5'

2'

0"

5'

M

IN

3x ROOTBALL - MIN.

5' DIA. MULCH RING

5' SQ. MIN. PREPARED AREA

EXISTING GRADE

NOTES:

1. REMOVE EXCESS SOIL FROM ROOTBALL TO EXPOSE ROOT FLARE AND

TRIM ANY SECONDARY/ADVENTITIOUS, GIRDLING AND POTENTIAL

GIRDLING ROOTS WITH CLEAN, SHARP PRUNING TOOLS.

2. 25' S.F. RIPPED AREA MIN. (SHOWN) - ODNR SUGGESTS 100 SQ. FT.

(10'X10')

ADJACENT LAWN OR PLANTING

BED - SEE PLAN

25 SQ. FT. MIN. PER TREE

PREPARED AREA - TYP.

TREE IN CENTER OF SPACE - TYP.

5' DIA. MULCH RING

USE 2 HARDWOOD STAKES AND OPPOSING

FLEXIBLE TIES WHEN STAKING IS NECESSARY

LAYER HARDWOOD BARK MULCH, KEEP MULCH 3" BACK

FROM TRUNK WITH 1" OF TOP-DRESSING OF EPA RATER

CLASS IV COMPOST FOR ENTIRE MULCH RING AREA

RIPPED NATIVE SOIL AMENDED WITH 2" DEPTH OF COMPOST

AND TILLED TO A DEPTH OF 10" - MIX THOROUGHLY

24" DEPTH OF RIPPED NATIVE SOIL

REMOVE ALL METAL TIES, ROPES, ETC. ENTIRELY

FROM ROOTBALL, AS WELL AS, THE TOP TWO-THIRDS

OF THE WIRE BASKET & BURLAP(IF ANY)

SET BALL ON FIRMLY PACKED SOIL BASE TO PREVENT

SETTLING - TOP OF ROOTBALL TO BE 2" ABOVE FINISHED

GRADE

BACKFILL TREE EXCAVATION WITH

EXCAVATED SOIL FROM HOLE

EXISTING UNDISTURBED NATIVE SOIL - DRIVE

STAKES 18" MIN. INTO UNDISTURBED SOIL

AS SPECIFIED

NOTES:

1. TOP OF ROOT BALL TO BE 2"-3" ABOVE ADJACENT FINISH

GRADE

2. REMOVE ROPE AND BURLAP FROM TOP 1/3 OF ROOT BALL.

CUT TOP 1/3 OF WIRE BASKET FROM ROOT BALL. REMOVE

ALL LABELS,TAGS OR OTHER FOREIGN MATERIALS FROM

LIMBS.

UNDISTURBED SOIL OR COMPACTED BACKFILL

EXISTING SOIL

BACKFILL PLANTING MIX

FINISH GRADE

HARDWOOD BARK MULCH

BUS SHELTER

Scale: 1" = 20' - 0" Landscape Plan1

PLANTING CONSTRUCTION NOTES:

CONTRACTOR SHALL REVIEW THE EXISTING

IRRIGATION SYSTEM AND VERIFY THAT

ADEQUATE COVERAGE IS PROVIDED FOR

PROPOSED PLANT MATERIAL. THE EXISTING

SYSTEM SHALL BE EVALUATED BY A QUALIFIED

IRRIGATION DESIGN PROFESSIONAL AND

MODIFIED AS NECESSARY TO ENSURE FULL

IRRIGATION. COVERAGE OF ALL NEW AND

EXISTING PLANTING AREAS.

EXISTING TREE TO BE REMOVED & PREPARE

SURFACE FOR NEW PLANTING

REPAIR LAWN AREA, FILL VOIDS WITH

TOPSOIL AS REQUIRED AND MEET ADJACENT

SURFACES FLUSH. PROVIDE POSITIVE

DRAINAGE ACROSS ALL SURFACES.

NEW LAWN AREA, FILL AREA WITH TOPSOIL,

AS REQUIRED TO BRING TO GRADE,

PROVIDING TOPSOIL ON TOP 6" AND

MEETING ADJACENT SURFACES FLUSH.

PROVIDE POSITIVE DRAINAGE ACROSS ALL

SURFACES.

LANDSCAPE AREA, PROVIDE MINIMUM DEPTH

OF 18" SOIL MIX. SEE SPECIFICATIONS FOR

SOIL MIX. HOLD TOP OF SOIL DOWN 3"

FROM TOP OF CURB AND/OR ADJACENT

PAVEMENT TO ALLOW FOR INSTALLATION OF

MULCH. PROVIDE POSITIVE DRAINAGE

ACROSS ALL SURFACES.

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

RLB NO.:

CHECKED BY:

DRAWN BY:

TA

RT

A

TA

SK

13828.10

W C

EN

TR

AL

A

VE

TO

LE

DO

, O H

LA

ND

SC

AP

E

PL

AN

SA

TB

L-1.1

Description

© RICHARD L. BOWEN + ASSOCIATES, INC.

S

O

UT

H M

IC

HI

G A

N S

TR

EE

T, S

UI

TE

TO

LE

D O

, O H

9.

5.

w w w

.e d ge la

.c om

1 03.16.26 25% SD SET

PLANT SCHEDULE

ABV BOTANICAL NAME COMMON NAME QUANTITY SIZE SPACING

TREES

UH Ulmus 'Homestead' Homestead Elm 3 2" CAL.

AG Acer griseum Paperbark Maple 6 2" CAL.

SHRUBS

DS Diervilla splendens 'G2X885411' Kodiak Red Diervilla 19 3 GAL. AS SHOWN

JP Juniperus x pfitzeriana 'Sea Green' Sea Green Juniper 96 3 GAL. 30" O.C.

GRASSES & GROUNDCOVERS

PVS Panicum virgatum 'Shenandoah' Shenandoah Switch Grass 8 3 GAL. AS SHOWN

HB Hemerocallis 'Big Time Happy' Big Time Happy Daylily 78 1 GAL. 18" O.C.

Scale: 1/4" = 1' - 0" TREE PLANTING DETAIL2 Scale: 1/4" = 1' - 0"

SHRUB PLANTING DETAIL3 Scale: 1/4" = 1' - 0"

GROUNDCOVER PLANTING DETAIL4

GENERAL NOTES:

1. EXAMINE FINISH SURFACE, GRADES, TOPSOIL

QUALITY AND DEPTH. DO NOT START ANY WORK

UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN

CORRECTED. VERIFY LIMITS OF WORK BEFORE

STARTING.

2. CONTRACTOR IS RESPONSIBLE FOR COST OF

REPAIRS TO EXISTING CONDITIONS WHEN

DAMAGED BY CONTRACTOR. REPAIR DAMAGES

TO THE SATISFACTION OF THE OWNER.

3. ALL PLANT MASSES TO BE CONTAINED WITHIN 3"

DEEP HARDWOOD BARK MULCH BED.

4. CONTRACTOR SHALL MAINTAIN POSITIVE

DRAINAGE IN ALL LAWN AREAS.

5. FINE GRADE LAWN AREAS TO PROVIDE A SMOOTH

AND CONTINUAL GRADE FREE OF IRREGULARITIES

OR DEPRESSIONS.

6. CONTRACTOR SHALL SEED ALL AREAS DISTURBED

DURING CONSTRUCTION, SEE PLAN.

7. ALL PLANTS SHALL MEET OR EXCEED STANDARDS SET

IN THE U.S.A. STANDARD FOR NURSERY STOCK.

8. ALL PLANTING OPERATIONS SHALL ADHERE TO THE

AMERICAN ASSOCIATION OF NURSERYMEN

STANDARDS.

ALTERNATE #1 - SEE DETAIL THIS SHEET

Scale: 1" = 10'-0"

ALTERNATE 15

NOTE: ADD 10 SEA GREEN JUNIPERS

2 05.26.26 CD SET

3 06.04.26 CD SET

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

4 06.16.26 BID & PERMIT

AutoCAD SHX Text

ICV

AutoCAD SHX Text

ICV

AutoCAD SHX Text

ICV

AutoCAD SHX Text

ICV

AutoCAD SHX Text 844+00

AutoCAD SHX Text 845+00

AutoCAD SHX Text 846+00

AutoCAD SHX Text 847+00

AutoCAD SHX Text 848+00

AutoCAD SHX Text 849+00

AutoCAD SHX Text 844+00

AutoCAD SHX Text 845+00

AutoCAD SHX Text 846+00

AutoCAD SHX Text 847+00

AutoCAD SHX Text 848+00

AutoCAD SHX Text 849+00

AutoCAD SHX Text

PROPOSED WALK (TYP)

AutoCAD SHX Text

NORTH

AutoCAD SHX Text 40'

AutoCAD SHX Text 20'

AutoCAD SHX Text 10'

AutoCAD SHX Text 0'

AutoCAD SHX Text S

AutoCAD SHX Text C

AutoCAD SHX Text T

AutoCAD SHX Text L

AutoCAD SHX Text D

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text J.

AutoCAD SHX Text

BOCKBRADER

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text I

AutoCAD SHX Text H

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text C

AutoCAD SHX Text

TIMOTHY

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text H

AutoCAD SHX Text O

AutoCAD SHX Text I

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text G

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text D

A5.1

A5.1

A5.1

A5.1

SURFACE MTD LIGHT FIXTURE

- SEE ELECT.

260000.C

STEEL FRAMING - SEE

STRUCTURAL

051200.A

METAL COMPOSITE MATERIAL

PANELS

074213.23

ALUMINUM FRAMED SKYLIGHT

086300.A

ALUMINUM CURTAIN WALLS

084413

0.5 1 4.54

31' - 5"

5" 10"

5" 9"

10"

/2

A5.1

A5.1

A5.1

A5.1

ALUMINUM FRAMED SKYLIGHT

086300.A

STEEL FRAMING - SEE

STRUCTURAL

051200.A

METAL COMPOSITE MATERIAL

PANELS

074213.23

A A

B B

9"

1" 5"

31' - 5"

0.5 1 4.542 3

5" 30' - 2" 10"

A3.11

A3.1

A3.1 4

A3.1

1' - 7"

NEW CONCRETE SLAB

28' - 4" 1' - 6"

3" 1' - 2" 11' - 10" 1' - 2" 3"

14' - 8"

16' - 4"

3" 1' - 2" 13' - 6" 1' - 2" 3"

6'

2'

3'

9'

(2) TRASH RECEPTACLES

N E

W C

O N

C R

E T

E S

LA

B

A5.1

A5.1

A5.1

A5.1

2"

R O

O F

A B

O V

E

3"

120°

ROOF ABOVE

31' - 5"

5"

VARIES ABOVE - SEE ELEVATIONS

12' - 11" 2' - 6"

8"

2"

V A

R

IE

S

2'

1'

" V

A R

IE

S

2'

1' - 0"

VARIES ABOVE - SEE ELEVATIONS

12' - 8" 6"

A

B

0.5 1 4.54

2' - 2"

120°

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

RLB NO.:

CHECKED BY:

DRAWN BY:

Description

C en te r

S t, S ui te

C le ve la nd

O hi o

P ho ne

(2

1-

6)

-8 w w w .r lb a.

co m

N O T F

O R

C O N S T R U C T

IO

N

© RICHARD L. BOWEN + ASSOCIATES, INC.

6/

/2

2:

:0

P

M A ut od es k

D oc s:

//T

A R

T A

C en tr al A ve G ar ag e S ite Im pr ov em en ts /A

R C

H _T

A R

T A

-C en tr al

A ve

G ar ag e

S ite

_1

-1

0.

rv t

C en tr al

A ve nu e

G ar ag e

S ite

Im pr ov em en ts

13828.10

C en tr al

A ve

T ol ed o, O

H

B U

S S

H E

LT

E

R P

LA

N

S

TLR

KJE

A1.1

SCALE: 1/2" = 1'-0"A1.1

FLOOR PLAN3

SCALE: 1/2" = 1'-0"A1.1

ROOF PLAN2

SCALE: 1/2" = 1'-0"A1.1

REFLECTED CEILING PLAN1

SCALE: NOT TO SCALEA1.1

3D4

06/05/26 100% CONST. DOCS

ADD ALTERNATE 01

LEVEL 01

0"

LEVEL 01

0"

TOP OF STEEL (HIGH END)

11' - 6"

LED SIGNAGE,

SEE ELECTRICAL

ALUMINUM CURTAIN WALLS

084413

RECESSED

LETTER SIGNAGE

1'

3" 9'

CAST-IN-PLACE CONCRETE

033000

METAL COMPOSITE MATERIAL

PANELS

074213.23

LED SIGNAGE,

BY OTHERS

TOP OF STEEL (LOW END)

11' - 0"

9'

1" S

H

IM

S P

A C

E

1'

2" 10" 2' - 4" 3" 2' - 0" 3"

R8' - 0"

2'

1' - 1"

LEVEL 01

0"

LEVEL 01

0"

TOP OF STEEL (HIGH END)

11' - 6"

TOP OF STEEL (HIGH END)

11' - 6"

LED DISPLAY BOARD,

BY OTHERS.

SEE ELECTRICAL.

1/

2"

1/

2" 6"

11' - 5 1/2"

6'

2'

LED SIGNAGE,

SEE ELECTRICAL.

3" 6" 26' - 10" 6" 3" 1' - 7"

9' - 0"

HPC-1

CAST-IN-PLACE CONCRETE

033000

METAL-FRAMED SKYLIGHTS

086300

ALUMINUM CURTAIN WALLS

084413

STEEL FRAMING - SEE

STRUCTURAL

051200.A

METAL COMPOSITE MATERIAL

PANELS

074213.23

1'

3" 8'

1'

1" S

H

IM

S P

A C

E 9'

2"

1'

R6' - 0"

3'

10' - 6"

10"

3"

4' - 10"

3"

LEVEL 01

0"

TOP OF STEEL (HIGH END)

11' - 6"

METAL BIKE RACK EMBEDDED IN CONCRETE BASE

1' - 7" 3" 6" 26' - 10" 6" 3" 1' - 6"

31' - 5"

CAST-IN-PLACE CONCRETE

033000

METAL COMPOSITE MATERIAL

PANELS

074213.23

ALUMINUM CURTAIN WALLS

084413

CAST-IN-PLACE CONCRETE

033000

TOP OF STEEL (LOW END)

11' - 0"

R6' - 0"

3"

2'

10' - 3"

8'

1'

8'

3" 1'

5' - 1"

LEVEL 01

0"

LEVEL 01

0"

TOP OF STEEL (HIGH END)

11' - 6"

LED SIGNAGE, SEE

ELECTRICAL

ALUMINUM CURTAIN WALLS

084413

RECESSED

LETTER SIGNAGE

METAL COMPOSITE MATERIAL

PANELS

074213.23

CAST-IN-PLACE CONCRETE

033000

1'

1" S

H

IM

S P

A C

E 8'

1"

TOP OF STEEL (LOW END)

11' - 0"

1/2" / 1'-0"

10" 2' - 4" 2"3" 2' - 0" 3"

R8'

- 8

1' - 2"

1'

1"

1'

3" 8'

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

RLB NO.:

CHECKED BY:

DRAWN BY:

Description

C en te r

S t, S ui te

C le ve la nd

O hi o

P ho ne

(2

1-

6)

-8 w w w .r lb a.

co m

© RICHARD L. BOWEN + ASSOCIATES, INC.

6/

/2

2:

:0

P

M A ut od es k

D oc s:

//T

A R

T A

C en tr al A ve G ar ag e S ite Im pr ov em en ts /A

R C

H _T

A R

T A

-C en tr al

A ve

G ar ag e

S ite

_1

-1

0.

rv t

C en tr al

A ve nu e

G ar ag e

S ite

Im pr ov em en ts

13828.10

C en tr al

A ve

T ol ed o, O

H

B U

S S

H E

LT

E

R E

LE

V

A T

IO

N

S

TLR

KJE

A3.1

SCALE: 1/2" = 1'-0"A3.1

EAST ELEVATION1

SCALE: 1/2" = 1'-0"A3.1

NORTH ELEVATION2

SCALE: 1/2" = 1'-0"A3.1

WEST ELEVATION4

SCALE: 1/2" = 1'-0"A3.1

SOUTH ELEVATION3

FINISH SCHEDULE

TAG MATERIAL MANUFACTURER COLOR CODE COLOR SPEC REFERENCE NOTES

COATING

HPC-1 HIGH PERFORMANCE COATING TBD 09 96 00 ARCHITECT TO SELECT, COORDINATE WITH TARTA

BRANDING

GLASS

LG-1 LAMINATED GLAZING 08 80 00

METALS

MTL-1 METAL WALL PANELS TBD 07 42 13.23 ARCHITECT TO SELECT, COORDINATE WITH TARTA

BRANDING

MTL-2 METAL ROOF TBD 07 41 13 ARCHITECT TO SELECT, COORDINATE WITH TARTA

BRANDING

MTL-3 METAL FASCIA MATCH MTL-1 07 71 00

MTL-4 METAL FASCIA MATCH MTL-7 07 71 00

MTL-5 GUTTERS & DOWNSPOUTS MATCH MTL-1 07 71 23

MTL-6 BIKE RACK STAINLESS STEEL

MTL-7 CW MULLIONS CLEAR ANODIZED 08 44 13

MTL-8 SKYLIGHT CLEAR ANODIZED 08 63 00

WOOD

WD-1 WOOD FINISH CUTEK - TBD 06 20 00

ADD ALTERNATE 01

06/05/26 100% CONST. DOCS

LEVEL 01

0"

LEVEL 01

0"

TOP OF STEEL (HIGH END)

11' - 6"

A5.2

A5.2

A5.2

AB

TOP OF STEEL (LOW END)

11' - 0"

LED SIGNAGE,

REF ELECTRICAL

NEW CONCRETE SLAB

12' - 6"

REINFORCED CONCRETE SLAB

ON GRADE - SEE STRUCTURAL

033000.A

JOINT FILLER STRIPS

033000.E

ALUMINUM CURTAIN WALLS

084413

STEEL TUBE - SEE

STRUCTURAL

051200.E

STEEL FRAMING - SEE

STRUCTURAL

051200.A

METAL-FRAMED SKYLIGHTS

086300

LEVEL 01

0"

LEVEL 01

0"

TOP OF STEEL (HIGH END)

11' - 6"

A5.2

A5.2

AB

TOP OF STEEL (LOW END)

11' - 0"

LED SIGNAGE,

REF ELECTRICAL

RECESSED

LETTER SIGNAGE

LED DISPLAY BOARD,

BY OTHERS

COLD-FORMED FURRING

CHANNEL

054000.E

METAL COMPOSITE MATERIAL

PANELS

074213.23

STEEL FRAMING - SEE

STRUCTURAL

051200.A

CELLULAR ROOF DECK - SEE

STRUCTURAL

053100.C

STANDING-SEAM METAL ROOF

PANELS

074113.B

ALUMINUM CURTAIN WALLS

084413

STEEL TUBE - SEE

STRUCTURAL

051200.E

SEALANT - BOTH SIDES

079200.C

SHIM - AS REQUIRED

061000.A2

CAST-IN-PLACE CONCRETE

033000

REINFORCED CONCRETE SLAB

ON GRADE - SEE STRUCTURAL

033000.A

NEW CONCRETE SLAB

12' - 6"

JOINT FILLER STRIPS

033000.E

6 INCH COLD-FORMED METAL

FRAMING

054000.B

PT WOOD BLOCKING

061000.A

2"

LEVEL 01

0"

A5.2

A5.2

0.5

1'

V A

R

IE

S

S E

E E

LE

V

A T

IO

N

8"

COLD-FORMED FURRING

CHANNEL

054000.E

3-5/8 INCH COLD-FORMED

METAL FRAMING

054000.A

METAL COMPOSITE MATERIAL

PANELS

074213.23

STEEL FRAMING - SEE

STRUCTURAL

051200.A

1' - 2" 3" 1' - 2" 5"

LEVEL 01

0"

A5.2

4.5

2"

A5.2

4"

ALUMINUM CURTAIN WALLS

084413

STEEL FRAMING - SEE

STRUCTURAL

051200.A

11" 8" 3" 1' - 7"

1'

1" V

A R

IE

S

A

LI

G

N T

O T

O P

O F

S T

E E

L 6"

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

RLB NO.:

CHECKED BY:

DRAWN BY:

Description

C en te r

S t, S ui te

C le ve la nd

O hi o

P ho ne

(2

1-

6)

-8 w w w .r lb a.

co m

© RICHARD L. BOWEN + ASSOCIATES, INC.

6/

/2

2:

:1

P

M A ut od es k

D oc s:

//T

A R

T A

C en tr al A ve G ar ag e S ite Im pr ov em en ts /A

R C

H _T

A R

T A

-C en tr al

A ve

G ar ag e

S ite

_1

-1

0.

rv t

C en tr al

A ve nu e

G ar ag e

S ite

Im pr ov em en ts

13828.10

C en tr al

A ve

T ol ed o, O

H

B U

S S

H E

LT

E

R S

E C

T

IO

N S

TLR

KJE

A5.1

SCALE: 3/4" = 1'-0"A5.1

WALL SECTION1

SCALE: 3/4" = 1'-0"A5.1

WALL SECTION2

SCALE: 3/4" = 1'-0"A5.1

WALL SECTION4

SCALE: 3/4" = 1'-0"A5.1

WALL SECTION3

ADD ALTERNATE 01

TOP OF STEEL (HIGH END)

11' - 6"

B

2"

1/2" / 1'-0"

1/2" / 1'-0"

ALUMINUM CURTAIN WALLS

084413

STEEL FRAMING - SEE

STRUCTURAL

051200.A

STEEL TUBE - SEE

STRUCTURAL

051200.E

STEEL FRAMING - SEE

STRUCTURAL

051200.A

WOOD BLOCKING

061000.A1

COLD-FORMED BENT PLATE

054000.G

MANUFACTURED METAL

COPING CAP

077100.A

METAL-FRAMED SKYLIGHTS

086300

FORMED TRANSITION

FLASHING

076200.K

7"

LEVEL 01

0"

B

3" 6" 3" 4"

1' - 4" 1' - 2"

2' - 6"

1'

1/

2"

1/ 2"

ALUMINUM CURTAIN WALLS

084413

SEALANT - BOTH SIDES

079200.C

WOOD BLOCKING

061000.A1

STEEL TUBE - SEE

STRUCTURAL

051200.E

CAST-IN-PLACE CONCRETE

033000

RECESSED

LETTER SIGNAGE

1"

3/4"

3/4" CHAMFER ON

CONCRETE

EDGES, TYP.

EMBED STEEL TUBE INTO CAST IN

PLACE CONCRETE, REF. STRUCT.

EMBED BIKE RACK INTO CAST IN

PLACE CONCRETE, REF. STRUCT.

JOINT FILLER STRIPS

033000.E

SEALANT - BOTH SIDES

079200.C

A

TOP OF STEEL (LOW END)

11' - 0"

STEEL FRAMING - SEE

STRUCTURAL

051200.A

STEEL FRAMING - SEE

STRUCTURAL

051200.A

CELLULAR ROOF DECK - SEE

STRUCTURAL

053100.C

COLD-FORMED FURRING

CHANNEL

054000.E

METAL COMPOSITE MATERIAL

PANELS

074213.23

6 INCH COLD-FORMED METAL

FRAMING

054000.B

METAL FLASHING

074113.H

STANDING-SEAM METAL ROOF

PANELS

074113.B

MANUFACTURED HANGING

GUTTER

077123.A

METAL-FRAMED SKYLIGHTS

086300

FORMED BASE FLASHING

076200.L

LEVEL 01

0"

A

THERMALLY MODIFIED WOOD SLATS

6" 10" 2"

3/4" CHAMFER ON

CONCRETE

EDGES, TYP.

METAL COMPOSITE MATERIAL

PANELS

074213.23

COLD-FORMED FURRING

CHANNEL

054000.E

3"

(BEYOND) EMBEDDED STEEL

TUBE IN CAST IN PLACE

CONCRETE, REF. STRUCT.

CAST-IN-PLACE CONCRETE

033000

1' - 10" 1' - 6"

5" 1'

1'

3' - 4"

062000

3/4" 1' - 8 1/2" 3/4" 3/4"

1/4" / 1'-0"

6 INCH COLD-FORMED METAL

FRAMING

054000.B

JOINT FILLER STRIPS

033000.E

CUSTOM EXTRUSIONS

084413.N

SEALANT - BOTH SIDES

079200.C

PANEL ANCHOR CLIP

074213.23C

A

TOP OF STEEL (LOW END)

11' - 0"

6 INCH COLD-FORMED METAL

FRAMING

054000.B

CELLULAR ROOF DECK - SEE

STRUCTURAL

053100.C

STANDING-SEAM METAL ROOF

PANELS

074113.B

METAL COMPOSITE MATERIAL

PANELS

074213.23

STEEL FRAMING - SEE

STRUCTURAL

051200.A

STEEL FRAMING - SEE

STRUCTURAL

051200.A

MANUFACTURED HANGING

GUTTER

077123.A

COLD-FORMED FURRING

CHANNEL

054000.E

5" 5"

DRIP EDGE

077123.F

0.5

STEEL FRAMING - SEE

STRUCTURAL

051200.A

COLD-FORMED FURRING

CHANNEL

054000.E

METAL FLASHING

074113.H

CELLULAR ROOF DECK - SEE

STRUCTURAL

053100.C

WOOD BLOCKING

061000.A1

STANDING-SEAM METAL ROOF

PANELS

074113.B

METAL COMPOSITE MATERIAL

PANELS

074213.23

8"

8"

LEVEL 01

0"

JOINT FILLER STRIPS

033000.E

REINFORCED CONCRETE SLAB

ON GRADE - SEE STRUCTURAL

033000.A

COLD-FORMED FURRING

CHANNEL

054000.E

3-5/8 INCH COLD-FORMED

METAL FRAMING

054000.A

METAL COMPOSITE MATERIAL

PANELS

074213.23

3"

CAST-IN-PLACE CONCRETE

033000

FINISH CARPENTRY

062000

THERMALLY MODIFIED WOOD SLATS

CUSTOM EXTRUSIONS

084413.N

SEALANT - BOTH SIDES

079200.C

PANEL ANCHOR CLIP

074213.23C

1'

5"

3" 4" 7" 3"

LEVEL 01

0"

1' - 7"3"

7" 6" 6"

3/4" CHAMFER ON

CONCRETE EDGES, TYP.

1'

SEALANT - BOTH SIDES

079200.C

WOOD BLOCKING

061000.A1

CAST-IN-PLACE CONCRETE

033000

JOINT FILLER STRIPS

033000.E

ALUMINUM CURTAIN WALLS

084413

1"

REINFORCED CONCRETE SLAB

ON GRADE - SEE STRUCTURAL

033000.A

4.5

4"

2" H

O

LD

F O

R D

E F

LE

C

T

IO

N

STEEL FRAMING - SEE

STRUCTURAL

051200.A

WOOD BLOCKING

061000.A1

CURTAIN WALL ANCHORS - AS

REQUIRED

084413.M

COLD-FORMED BENT PLATE

054000.G

MANUFACTURED METAL

COPING CAP

077100.A

METAL-FRAMED SKYLIGHTS

086300

ALUMINUM CURTAIN WALLS

084413

CURTAIN WALL FRAMING

084413.A

7"

CUSTOM FRAME PROFILE

ISSUES AND REVISIONS

DateNo.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

RLB NO.:

CHECKED BY:

DRAWN BY:

Description

C en te r

S t, S ui te

C le ve la nd

O hi o

P ho ne

(2

1-

6)

-8 w w w .r lb a.

co m

© RICHARD L. BOWEN + ASSOCIATES, INC.

6/

/2

2:

:1

P

M A ut od es k

D oc s:

//T

A R

T A

C en tr al A ve G ar ag e S ite Im pr ov em en ts /A

R C

H _T

A R

T A

-C en tr al

A ve

G ar ag e

S ite

_1

-1

0.

rv t

C en tr al

A ve nu e

G ar ag e

S ite

Im pr ov em en ts

13828.10

C en tr al

A ve

T ol ed o, O

H

B U

S S

H E

LT

E

R D

E T

A

IL

S

TLR

KJE

A5.2

SCALE: 1 1/2" = 1'-0"A5.2

SECTION DETAIL8

SCALE: 1 1/2" = 1'-0"A5.2

SECTION DETAIL4

SCALE: 1 1/2" = 1'-0"A5.2

SECTION DETAIL10

SCALE: 1 1/2" = 1'-0"A5.2

SECTION DETAIL1

SCALE: 1 1/2" = 1'-0"A5.2

SECTION DETAIL5

SCALE: 1 1/2" = 1'-0"A5.2

SECTION DETAIL7

SCALE: 1 1/2" = 1'-0"A5.2

SECTION DETAIL3

SCALE: 1 1/2" = 1'-0"A5.2

SECTION DETAIL2

ADD ALTERNATE 01

SCALE: 1 1/2" = 1'-0"A5.2

SECTION DETAIL11

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

C

EN

TR

AL

A

VE

NU

E, T

OL

ED

O, O H

0 L

UC

AS

C

OU

NT

Y

ST

RU

CT

UR

AL

N

OT

ES

A

ND

S

PE

CI

FI

CA

TI

ON

S

SMC

KWL

S0.1

Ju n 2

3, :59 am Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

ST

RU

CT

UR

AL

\D wg \24

7_

S

T.

dw g:

S0

.1

NO

TE

S

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

06.05.261 CD Set

June 16, 2026

STA

TE OF OHIO

PROFESS IONAL ENG I N

EE

R

KYLE W.

LAYTON

E-82893

R EG I S T ER E D

06.16.262 Bid & PermitSTRUCTURAL NOTES

AutoCAD SHX Text

TYPE 1

AutoCAD SHX Text

TYPE 2

AutoCAD SHX Text

TYPE 3

AutoCAD SHX Text

TYPE 4

AutoCAD SHX Text

TYPE 5

AutoCAD SHX Text

TYPE 6

AutoCAD SHX Text 9"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text MIN LAP SPLICE LENGTH (UNLESS NOTED OTHERWISE) BAR LENGTH (IN) LENGTH (IN) #4 30 30 #5 36 36 #6 44 44 #7 54 54 #8 7272

AutoCAD SHX Text F1554 GRADE 36 HEADED ANCHOR BOLTS BOLT LENGTH MIN. PROJECTION LENGTH MIN. PROJECTION MIN. PROJECTION 34" 18" 8" 18" 8" 8" PROJECTION IS FROM THE TOP OF CONCRETE. BOLT LENGTHS ARE MEASURED FROM TOP OF THREADS TO TOP OF HEADED PLATE AND ARE CONSIDERED MINIMUM. SEE BUILDING SUPERSTRUCTURE DRAWINGS FOR ADDITIONAL BOLT DETAILS AND SPECIFICATIONS.

AutoCAD SHX Text

HEADED ANCHOR BOLT

AutoCAD SHX Text

%%USTANDARD

AutoCAD SHX Text

%%UALTERNATIVE

AutoCAD SHX Text

ANCHOR ROD

AutoCAD SHX Text

BASE PLATE

AutoCAD SHX Text

BASE PLATE

AutoCAD SHX Text

LENGTH

AutoCAD SHX Text

LENGTH

AutoCAD SHX Text

F436 STRUCTURAL WASHER, TYP.

AutoCAD SHX Text

A563 HEAVY HEX NUT, TYP.

AutoCAD SHX Text

F436 STRUCTURAL WASHER, TYP.

AutoCAD SHX Text

A563 HEAVY HEX NUT, TYP.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

TYPICAL ANCHOR BOLT DETAIL

AutoCAD SHX Text 3" = 1'-0"

AutoCAD SHX Text NOTE ON REINFORCING STEEL: WHERE DIMENSIONS ARE NOT SHOWN ON THE BAR TYPE DIAGRAM, BARS SHALL BE DIMENSIONED UTILIZING THE APPROPRIATE CLEARANCE REQUIREMENTS AS OUTLINED IN THE PLAN DETAILS AND NOTES.

GENERAL 1. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO ALL THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO ALL CONSTRUCTION, INCLUDING COORDINATION BETWEEN STRUCTURAL AND ARCHITECTURAL DRAWINGS, AND DISCREPANCIES FOUND SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE WORK BEGINS. 2. ALL CONSTRUCTION SHALL CONFORM TO THE CURRENT VERSION OF THE FOLLOWING: ALL CONSTRUCTION SHALL CONFORM TO THE CURRENT VERSION OF THE FOLLOWING: 2.1. INTERNATIONAL BUILDING CODE AND OHIO BUILDING CODE INTERNATIONAL BUILDING CODE AND OHIO BUILDING CODE 2.2. ACI 318 - BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE ACI 318 - BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE 2.3. ACI 301 - SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS ACI 301 - SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS 2.4. AISC 360 - DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL AISC 360 - DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL 2.5. AISI S100-16 - NORTH AMERICAN SPECIFICATIONS FOR DESIGN OF COLD-FORMED STEEL AISI S100-16 - NORTH AMERICAN SPECIFICATIONS FOR DESIGN OF COLD-FORMED STEEL 3. REFERENCE PAD ELEVATION FOR 0'-0" = 608.00 REFERENCE PAD ELEVATION FOR 0'-0" = 608.00 LOADS 1. DESIGN NET ALLOWABLE BEARING PRESSURE (NATIVE SOIL) IS 1,500 PSF FOR REINFORCED DESIGN NET ALLOWABLE BEARING PRESSURE (NATIVE SOIL) IS 1,500 PSF FOR REINFORCED SLAB-ON-GRADE. 2. THE DESIGN LOADS FOR THIS STRUCTURE WERE CALCULATED BASED ON THE PROVISIONS WITHIN THE DESIGN LOADS FOR THIS STRUCTURE WERE CALCULATED BASED ON THE PROVISIONS WITHIN ASCE 7-16. 3. DESIGN CRITERIA: DESIGN CRITERIA: 3.1. DEAD LOADS DEAD LOADS 3.1.1. CONSIST OF ACTUAL WEIGHTS OF BUILDING MATERIALS. CONSIST OF ACTUAL WEIGHTS OF BUILDING MATERIALS. 3.1.2. ROOF LOADS = 5 PSF ROOF LOADS = 5 PSF 3.1.3. COLLATERAL LOAD = 5 PSF COLLATERAL LOAD = 5 PSF 3.2. LIVE LOADS LIVE LOADS 3.2.1. ROOF LOADS = 20 PSF ROOF LOADS = 20 PSF 3.3. SNOW LOADS SNOW LOADS 3.3.1. GROUND SNOW LOAD = 20 PSF GROUND SNOW LOAD = 20 PSF 3.3.2. FLAT-ROOF SNOW LOAD = 20 PSF FLAT-ROOF SNOW LOAD = 20 PSF 3.3.3. SNOW EXPOSURE FACTOR = 0.9 SNOW EXPOSURE FACTOR = 0.9 3.3.4. IMPORTANCE FACTOR = 1.0 IMPORTANCE FACTOR = 1.0 3.3.5. THERMAL FACTOR = 1.2 THERMAL FACTOR = 1.2 3.3.6. RAIN ON SNOW SURCHARGE = 5 PSF RAIN ON SNOW SURCHARGE = 5 PSF 3.4. WIND LOADS WIND LOADS 3.4.1. BASIC WIND SPEED = 107 MPH (3-SEC GUST) BASIC WIND SPEED = 107 MPH (3-SEC GUST) 3.4.2. WIND CODE OBC 24 WIND CODE OBC 24 3.4.3. IMPORTANCE FACTOR = 1.0 IMPORTANCE FACTOR = 1.0 3.4.4. EXPOSURE CATEGORY (B) EXPOSURE CATEGORY (B) 3.4.5. ENCLOSURE: OPEN ENCLOSURE: OPEN SUBMITTALS 1. REVIEW SUBMITTALS SHALL BE MADE IN A TIMELY FASHION FOR THE FOLLOWING: REVIEW SUBMITTALS SHALL BE MADE IN A TIMELY FASHION FOR THE FOLLOWING: 1.1. STRUCTURAL AND MISCELLANEOUS STEEL ELEMENTS STRUCTURAL AND MISCELLANEOUS STEEL ELEMENTS 1.2. REINFORCING STEEL REINFORCING STEEL 1.3. CONCRETE MIX DESIGNS CONCRETE MIX DESIGNS BACKFILLING 1. ONCE THE SUBGRADE HAS BEEN PROPERLY PREPARED, BACKFILL MATERIAL SHALL BE PLACED IN ONCE THE SUBGRADE HAS BEEN PROPERLY PREPARED, BACKFILL MATERIAL SHALL BE PLACED IN ORDER TO OBTAIN THE DESIRED FINAL GRADES. IT IS ANTICIPATED THAT WELL-GRADED STONE MEETING THE REQUIREMENTS OF ODOT CMS 304 WILL PERFORM WELL FOR THE STRUCTURAL BACKFILL. OTHER SUITABLE MATERIALS CAN BE UTILIZED WITH THE APPROVAL OF THE GEOTECHNICAL ENGINEER. 2. BACKFILL SHALL BE PLACED IN A MAXIMUM OF 8" LOOSE LIFT THICKNESS. EACH LIFT SHALL BE BACKFILL SHALL BE PLACED IN A MAXIMUM OF 8" LOOSE LIFT THICKNESS. EACH LIFT SHALL BE COMPACTED WITH A POWER VIBRATING COMPACTOR OR SIMILAR EQUIPMENT TO INSURE MAXIMUM COMPACTION OF THE MATERIAL. 3. INTERIOR BACKFILL SHALL BE APPROVED BY GEOTECHNICAL ENGINEER COMPACTED TO A MINIMUM INTERIOR BACKFILL SHALL BE APPROVED BY GEOTECHNICAL ENGINEER COMPACTED TO A MINIMUM OF 95% STANDARD PROCTOR. FOUNDATIONS & SLABS 1. NO SOILS REPORT WAS PREPARED FOR THIS PROJECT. DESIGNS INCLUDED IN THESE PLANS ARE NO SOILS REPORT WAS PREPARED FOR THIS PROJECT. DESIGNS INCLUDED IN THESE PLANS ARE BASED ON MINIMUM DESIGN REQUIREMENTS AS DESIGNATED BY THE OHIO BUILDING CODE. ALL FOOTINGS AND SLABS INSTALLED AS PART OF THIS PROJECT SHALL BEAR ON COMPETENT NATIVE SOIL. 2. FOUNDATION DETAILS AND ELEVATIONS INCLUDED WITHIN THE DRAWINGS ARE BASED ON ASSUMED FOUNDATION DETAILS AND ELEVATIONS INCLUDED WITHIN THE DRAWINGS ARE BASED ON ASSUMED FIELD CONDITIONS. UPON SOIL INSPECTION BY THE GEOTECHNICAL ENGINEER, IT MAY BE REQUIRED TO REPLACE EXISTING FILL WITH SPECIFIED ENGINEERED FILL TO ENSURE ADEQUATE BEARING. 3. FOOTINGS AND SLABS SHALL BEAR ON LEVEL, UNDISTURBED SOIL OR APPROVED ENGINEERED FILL. FOOTINGS AND SLABS SHALL BEAR ON LEVEL, UNDISTURBED SOIL OR APPROVED ENGINEERED FILL. CAST-IN-PLACE CONCRETE 1. CONCRETE SHALL BE AS FOLLOWS: CONCRETE SHALL BE AS FOLLOWS: 1.1. SLABS ON GRADE- F'C = 4,000 PSI AT 28 DAYS WITH 6% MAXIMUM AIR ENTRAINMENT, SLABS ON GRADE- F'C = 4,000 PSI AT 28 DAYS WITH 6% MAXIMUM AIR ENTRAINMENT, MIN. 145 PCF 2. ALL EXPOSED CORNERS SHALL RECEIVE A " CHAMFER UNLESS NOTED OTHERWISE. ALL EXPOSED CORNERS SHALL RECEIVE A " CHAMFER UNLESS NOTED OTHERWISE. 34" CHAMFER UNLESS NOTED OTHERWISE. 3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615-GRADE 60 ALL REINFORCING BARS SHALL CONFORM TO ASTM A615-GRADE 60 4. CLEARANCE BETWEEN REINFORCING AND CONCRETE SURFACES CLEARANCE BETWEEN REINFORCING AND CONCRETE SURFACES 4.1. UNFORMED - 3" UNFORMED - 3" 4.2. FORMED AND EXPOSED TO WEATHER OR EARTH - 2" FORMED AND EXPOSED TO WEATHER OR EARTH - 2" 4.3. FORMED BUT NOT EXPOSED TO WEATHER OR EARTH - 1 " FORMED BUT NOT EXPOSED TO WEATHER OR EARTH - 1 " 12" 5. FLOOR SLAB SHALL BE TREATED WITH A CURE AND SEAL WHEN POURED. FLOOR SLAB SHALL BE TREATED WITH A CURE AND SEAL WHEN POURED. 6. ALL EXPOSED CONCRETE SURFACES SHALL BE PATCHED AND HAVE A HAND RUBBED FINISH. ALL EXPOSED CONCRETE SURFACES SHALL BE PATCHED AND HAVE A HAND RUBBED FINISH. 7. CONCRETE SHALL BE CURED AND SEALED WITH DIAMOND CLEAR V0X BY EUCLID CHEMICAL OR CONCRETE SHALL BE CURED AND SEALED WITH DIAMOND CLEAR V0X BY EUCLID CHEMICAL OR APPROVED EQUIVALENT. 8. ISOLATION JOINTS SHALL BE FILLED WITH AN ASPHALT IMPREGNATED FIBERBOARD OR APPROVED ISOLATION JOINTS SHALL BE FILLED WITH AN ASPHALT IMPREGNATED FIBERBOARD OR APPROVED EQUIVALENT. STRUCTURAL STEEL 1. STRUCTURAL TUBES SHALL BE ASTM A500 GRADE B. STRUCTURAL TUBES SHALL BE ASTM A500 GRADE B. 2. ROLLED ANGLES AND PLATES SHALL BE ASTM A36 OR HIGHER GRADE. ROLLED ANGLES AND PLATES SHALL BE ASTM A36 OR HIGHER GRADE. 3. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH LOAD AND RESISTANCE (LRFD) STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH LOAD AND RESISTANCE (LRFD) DESIGN PROCEDURES AS REQUIRED BY "AISC MANUAL OF STEEL CONSTRUCTION", UNLESS NOTED OTHERWISE. 4. ALL PROJECTED CORNERS, EXPOSED EDGES, BURRS AND SHARP CORNERS SHALL BE GROUNDED ALL PROJECTED CORNERS, EXPOSED EDGES, BURRS AND SHARP CORNERS SHALL BE GROUNDED SMOOTH. 5. CONNECTION DESIGN: CONNECTION DESIGN: 5.1. THESE PLANS INCLUDE DETAILS FOR ALL STRUCTURAL CONNECTIONS THAT DO NOT QUALIFY THESE PLANS INCLUDE DETAILS FOR ALL STRUCTURAL CONNECTIONS THAT DO NOT QUALIFY AS SIMPLE SHEAR CONNECTIONS. IF A CONNECTION DESIGN IS INADVERTENTLY OMITTED FROM THE CONTRACT DOCUMENTS THE CONTRACTOR MAY REQUEST SPECIFIC WRITTEN CONNECTION DESIGN FROM THE STRUCTURAL ENGINEER. 5.1.1. ALL TUBE TO TUBE CONNECTIONS ARE CONSIDERED TO BE FULLY WELDED. ALL TUBE TO TUBE CONNECTIONS ARE CONSIDERED TO BE FULLY WELDED. 5.2. CONTRACTOR DEVIATIONS FROM CONNECTION DESIGNS SHOWN ON THE CONTRACT CONTRACTOR DEVIATIONS FROM CONNECTION DESIGNS SHOWN ON THE CONTRACT DOCUMENTS MAY BE ACCEPTED IF THE CONTRACTOR PROVIDES COMPLETE STRUCTURAL CALCULATIONS FOR APPROVAL. THE CALCULATIONS SHALL BE SEALED BY A PROFESSIONAL ENGINEER IN THE STATE OF OHIO. 5.3. BOLTED CONNECTIONS: BOLTED CONNECTIONS: 5.3.1. MINIMUM BOLT DIAMETER IS " UNLESS NOTED OTHERWISE. MINIMUM BOLT DIAMETER IS " UNLESS NOTED OTHERWISE. 34" UNLESS NOTED OTHERWISE. 5.3.2. ALL BOLTS SHALL BE A325N UNLESS OTHERWISE NOTED. ALL BOLTS SHALL BE A325N UNLESS OTHERWISE NOTED. 5.3.3. TWO BOLT MINIMUM PER CONNECTED MEMBER U.N.O. TWO BOLT MINIMUM PER CONNECTED MEMBER U.N.O. 5.3.4. ALL BOLT TYPES & HARDWARE SHALL BE HOT DIPPED GALVANIZED. ALL BOLT TYPES & HARDWARE SHALL BE HOT DIPPED GALVANIZED. 5.3.5. BOLTED CONNECTIONS SHALL BE CONSIDERED IN THE SNUG TIGHT CONDITION UNLESS BOLTED CONNECTIONS SHALL BE CONSIDERED IN THE SNUG TIGHT CONDITION UNLESS OTHERWISE NOTED. SNUG TIGHT CONDITION IS DEFINED AS THE TIGHTNESS THAT EXISTS WHEN ALL PLIES IN A JOINT ARE IN FIRM CONTACT. THIS MAY BE ACHIEVED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF A MAN USING AN ORDINARY SPUD WRENCH. 5.3.6. F1554 GRADE 36 BOLTS HAVE BEEN SPECIFIED FOR ANCHORING COLUMN BASE F1554 GRADE 36 BOLTS HAVE BEEN SPECIFIED FOR ANCHORING COLUMN BASE PLATES TO CONCRETE PIERS. 5.4. WELDED CONNECTIONS: WELDED CONNECTIONS: 5.4.1. GENERAL WELDING SHALL BE MADE WITH E70XX SERIES ELECTRODES AND IN GENERAL WELDING SHALL BE MADE WITH E70XX SERIES ELECTRODES AND IN ACCORDANCE WITH AWS SPECIFICATIONS. SHOP AND FIELD WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/AWS D1.1 REQUIREMENTS. 5.4.2. FILLET WELDS SHOULD CONFORM TO THE AISC MINIMUM BUT NOT LESS THAT ". FILLET WELDS SHOULD CONFORM TO THE AISC MINIMUM BUT NOT LESS THAT ". 14". 5.4.3. GROOVE WELDS: FULL PENETRATION UNLESS OTHERWISE NOTED. WELDS ARE GROOVE WELDS: FULL PENETRATION UNLESS OTHERWISE NOTED. WELDS ARE CONTINUOUS UNLESS NOTED. ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) 1. GENERAL SCOPE: GENERAL SCOPE: A. THIS PROJECT IS AN ENTIRELY EXPOSED STEEL STRUCTURE. ALL STRUCTURAL STEEL ON THIS PROJECT IS AN ENTIRELY EXPOSED STEEL STRUCTURE. ALL STRUCTURAL STEEL ON THIS PROJECT SHALL BE CLASSIFIED AS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS), LEVEL 4, AND SHALL COMPLY WITH THE AISC CODE OF STANDARD PRACTICE (AISC 303), SECTION 10. 2. FABRICATION, WELDING, & GRINDING: FABRICATION, WELDING, & GRINDING: A. ALL CONNECTIONS SHALL BE EXECUTED WITH A HIGH LEVEL OF CRAFTSMANSHIP. ALL ALL CONNECTIONS SHALL BE EXECUTED WITH A HIGH LEVEL OF CRAFTSMANSHIP. ALL VISIBLE SHOP AND FIELD WELDS SHALL BE CONTINUOUS, GROUND FLUSH OR SMOOTH, AND COMPLETELY FREE OF SLAG, SPATTER, OR UNDER_CUTS. PIECE MARKS, MILL STAMPS, AND HEAT NUMBERS SHALL BE ORIENTED AWAY FROM PUBLIC VIEW OR REMOVED ENTIRELY BY GRINDING. 3. SURFACE PREPARATION & BLASTING: SURFACE PREPARATION & BLASTING: A. ALL STEEL MEMBERS SHALL RECEIVE A COMMERCIAL BLAST CLEANING IN ACCORDANCE WITH ALL STEEL MEMBERS SHALL RECEIVE A COMMERCIAL BLAST CLEANING IN ACCORDANCE WITH SSPC-SP 6 PRIOR TO APPLYING SHOP PRIMER. THE PRIMER USED MUST BE EXPLICITLY COORDINATED WITH AND COMPATIBLE WITH THE FINAL ARCHITECTURAL FINISH PAINT SYSTEM. 4. ERECTION & PROTECTION: ERECTION & PROTECTION: A. THE STEEL ERECTOR IS RESPONSIBLE FOR DELIVERING DEFECT-FREE STEEL TO THE SITE. THE STEEL ERECTOR IS RESPONSIBLE FOR DELIVERING DEFECT-FREE STEEL TO THE SITE. NYLON SLINGS OR PADDED SOFTENERS SHALL BE USED EXCLUSIVELY DURING UNLOADING AND ERECTION. FIELD WELDS, TACK WELDS, AND ANY HANDLING GOUGES OR SCRATCHES SHALL BE GROUND SMOOTH AND PRIMED IMMEDIATELY AFTER INSTALLATION. 5. COORDINATION & MOCK-UPS: COORDINATION & MOCK-UPS: A. CONTRACTOR SHALL CROSS-REFERENCE ARCHITECTURAL SPECIFICATIONS SECTION 05 12 13 CONTRACTOR SHALL CROSS-REFERENCE ARCHITECTURAL SPECIFICATIONS SECTION 05 12 13 FOR FULL FINISH QUALITY STANDARDS, JOINT FILLER SUBMITTALS, AND DETAILS. THE ARCHITECTURAL SPECIFICATIONS SHALL GOVERN REGARDING FINAL VISUAL ACCEPTANCE AND REJECTION CRITERIA. PAINTING SPECIFICATIONS 1. MINIMUM PAINTING SPECIFICATION: MINIMUM PAINTING SPECIFICATION: 1.1. REFERENCE THE ARCHITECTURAL DRAWINGS AND PROJECT MANUAL FOR REQUIREMENTS AND REFERENCE THE ARCHITECTURAL DRAWINGS AND PROJECT MANUAL FOR REQUIREMENTS AND SPECIFICATIONS OF HIGH-PERFORMANCE COATING SYSTEM. PRIMER SHALL BE COORDINATED WITH AND COMPATIBLE WITH THE FINISH PAIN SYSTEM AND SHALL BE APPLIED TO A MINIMUM THICKNESS OF 1 MIL ON STEEL THAT HAS BEEN PREPARED IN ACCORDANCE WITH SSPC-SP2. 2. AREAS OF STEEL WHICH WILL RECEIVED FIELD WELDS SHALL BE LEFT UNPAINTED UNTIL AFTER AREAS OF STEEL WHICH WILL RECEIVED FIELD WELDS SHALL BE LEFT UNPAINTED UNTIL AFTER FIELD WELDING HAS BEEN COMPLETED. METAL ROOF DECK - CELLULAR B DECK (1.5) 1. MINIMUM DESIGN SPECIFICATIONS FOR METAL ROOF DECKING: MINIMUM DESIGN SPECIFICATIONS FOR METAL ROOF DECKING: 1.1. CELLULAR DECK SHALL FEATURE A FLAT STEEL PLATE FACTORY-ATTACHED TO THE BOTTOM CELLULAR DECK SHALL FEATURE A FLAT STEEL PLATE FACTORY-ATTACHED TO THE BOTTOM OF THE CORRUGATED DECK PROFILE. 1.1. DEPTH OF ROOF DECKING SHALL BE 1.5". DEPTH OF ROOF DECKING SHALL BE 1.5". 1.2. MINIMUM GAGE OF ROOF DECKING IS 22. MINIMUM GAGE OF ROOF DECKING IS 22. 1.3. MINIMUM YIELD STRENGTH OF ROOF DECKING IS 50 KSI. MINIMUM YIELD STRENGTH OF ROOF DECKING IS 50 KSI. 1.4. FINAL DETAILED DECK SHOP DRAWINGS SHALL BE PROVIDED TO PROJECT ENGINEER. FINAL DETAILED DECK SHOP DRAWINGS SHALL BE PROVIDED TO PROJECT ENGINEER. 1.5. DECKING SHALL HAVE GALVANIZED FINISH. DECKING SHALL HAVE GALVANIZED FINISH. 1.6. INSTALLER SHALL PROVIDE THESE MINIMUM FASTENING REQUIREMENTS OR AS REQUIRED BY INSTALLER SHALL PROVIDE THESE MINIMUM FASTENING REQUIREMENTS OR AS REQUIRED BY DECK MANUFACTURER. 1.6.1. " PUDDLE WELD @ 36/4 PATTERN. 58" PUDDLE WELD @ 36/4 PATTERN.

NOTICE

THIS ARCHITECTURAL AND

ENGINEERING DRAWING IS GIVEN

IN CONFIDENCE. NO USE OR

DISSEMINATION MAY BE MADE

WITHOUT PRIOR WRITTEN

CONSENT OF THE ARCHITECT.

ALL RIGHTS ARE HEREBY

SPECIFICALLY RESERVED.

DRAWING NO.

DGL NO.:

CHECKED BY:

DRAWN BY:

MO

BI

LIT

Y

DI

ST

RI

CT

T

RA

NS

IT

C

EN

TE

R

24177-10

C

EN

TR

AL

A

VE

NU

E, T

OL

ED

O, O H

0 L

UC

AS

C

OU

NT

Y

FO

UN

DA

TI

ON

P

LA

N

AN

D

DE

TA

ILS

SMC

KWL

S1.1

Ju n 2

3, :00 pm Description

C en ter S t, S uit e 5

/ C lev ela nd

, O hio

Ph on e:

(2

) 4

-9

F ax

6)

1-ww w.

rlb a.c om

M:

\24

7 (

Bo we n - T

AR

TA

On

C all

E ng ine er ing )\T as k 1

0 - Ce ntr al

Av e.

Si te

Im pr ov em en ts\

ST

RU

CT

UR

AL

\D wg \24

7_

S

T.

dw g:

S1

.1

FO

UN

DA

TI

ON

2026© RICHARD L. BOWEN + ASSOCIATES, INC.

DG

L

CO

N

SU

LT

IN

G

E N

G

IN

EE

RS

, L

LC

B

RI

AR

FI

EL

D

BL

VD

. S U

IT

E

E M

AU

M

EE

, O

H

PH

O

N E:

.5

.1 w w w

.d gl

-lt d.

co m

06.05.261 CD Set

06.16.262 Bid & Permit

June 16, 2026

STA

TE OF OHIO

PROFESS IONAL ENG I N

EE

R

KYLE W.

LAYTON

E-82893

R EG I S T ER E D

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text 10'-11"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

PLAN - SHELTER SLAB ON GRADE FOUNDATION

AutoCAD SHX Text 1" = 1'-0"

AutoCAD SHX Text 28'-4"

AutoCAD SHX Text 12'-6"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 7"

AutoCAD SHX Text

AutoCAD SHX Text S1.1

AutoCAD SHX Text

AutoCAD SHX Text S1.1

AutoCAD SHX Text 16'-4"

AutoCAD SHX Text 1'-5"

AutoCAD SHX Text 13'-6"

AutoCAD SHX Text 1'-5"

AutoCAD SHX Text 1'-6"

AutoCAD SHX Text 1'-10"

AutoCAD SHX Text 14'-8"

AutoCAD SHX Text 1'-5"

AutoCAD SHX Text 9"

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text 1'-5"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-2"

AutoCAD SHX Text 3'-4"

AutoCAD SHX Text 9'-2"

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 1'-2"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

MIN

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text

SECTION AT BENCH END

AutoCAD SHX Text 1" = 1'-0"

AutoCAD SHX Text

COMPACTED 304 AGGREGATE BASE, MINIMUM 6" THICK.

AutoCAD SHX Text 6"

AutoCAD SHX Text 3'-4"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

MIN.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text

TYP SECTION AT BENCH

AutoCAD SHX Text 1" = 1'-0"

AutoCAD SHX Text 6"

AutoCAD SHX Text 1'-6"

AutoCAD SHX Text 1'-10"

AutoCAD SHX Text 5"

AutoCAD SHX Text 5"

AutoCAD SHX Text

MIN

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text

TYP SECTION AT BIKE RACK

AutoCAD SHX Text 1" = 1'-0"

AutoCAD SHX Text 6"

AutoCAD SHX Text 8"

AutoCAD SHX Text 4"

AutoCAD SHX Text

COMPACTED 304 AGGREGATE BASE, MINIMUM 6" THICK.

AutoCAD SHX Text

AutoCAD SHX Text S1.1

AutoCAD SHX Text

AutoCAD SHX Text S1.1

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-2"

AutoCAD SHX Text

BEYOND

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

MIN

AutoCAD SHX Text 6"

AutoCAD SHX Text

VARIES

AutoCAD SHX Text

VARIES

AutoCAD SHX Text 1'-5" - 2'-2"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

AutoCAD SHX Text

SECTION AT BIKE RACK END

AutoCAD SHX Text 1" = 1'-0"

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text

COMPACTED 304 AGGREGATE BASE, MINIMUM 6" THICK.

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 8"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 9'-2"

AutoCAD SHX Text 10'-0"

AutoCAD SHX Text 8"

AutoCAD SHX Text 5'-4"

AutoCAD SHX Text 8"

AutoCAD SHX Text 3'-4"

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 8"

AutoCAD SHX Text 5'-4"

AutoCAD SHX Text 8"

AutoCAD SHX Text 3'-4"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1'-0 "916"

AutoCAD SHX Text 12'-3"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 11'-5"

AutoCAD SHX Text 1'-7 "716"

AutoCAD SHX Text

THICKENED SLAB

AutoCAD SHX Text 9"

AutoCAD SHX Text

#4 BAR, TYPE 1 REINFORCEMENT AT 12" C/C

AutoCAD SHX Text

#4, TYPE 2 REINFORCEMENT AT 12" C/C

AutoCAD SHX Text

#4 TYPE 2

AutoCAD SHX Text

#4 TYPE 4

AutoCAD SHX Text

#4 TYPE 4

AutoCAD SHX Text

#4 TYPE 6

AutoCAD SHX Text

#4 TYPE 6

AutoCAD SHX Text

#4 TYPE 6

AutoCAD SHX Text

#4 TYPE 6

AutoCAD SHX Text

#4 BARS SPA @ 12" C/C, E/W

AutoCAD SHX Text

COMPACTED 304 AGGREGATE BASE, MINIMUM 6" THICK.

AutoCAD SHX Text

#4 BARS SPA @ 12" C/C

AutoCAD SHX Text

PROVIDE CORNER REINFORCING TO MATCH LONGITUDINAL STEEL

AutoCAD SHX Text 10'-0"

AutoCAD SHX Text

PROVIDE CORNER REINFORCING TO MATCH LONGITUDINAL STEEL

AutoCAD SHX Text NOTE: SUPPLEMENTAL REINFORCING STEEL IS SHOWN ON THE SUPPLEMENTAL REINFORCING STEEL IS SHOWN ON THE FOUNDATION PLAN FOR CLARITY. FOR PRIMARY STEEL REINFORCEMENT THROUGHOUT, SEE APPROPRIATE SECTIONS AND DETAILS

AutoCAD SHX Text

(4) #5 LONGITUDINAL BAR

AutoCAD SHX Text

#4, TYPE 3 REINFORCEMENT AT 12" C/C

AutoCAD SHX Text

#4, TYPE 3 REINFORCEMENT AT 12" C/C

AutoCAD SHX Text

(4) #5 LONGITUDINAL BAR

AutoCAD SHX Text

(4) #5 LONGITUDINAL BAR

AutoCAD SHX Text

#4, TYPE 3 REINFORCEMENT AT 12" C/C

AutoCAD SHX Text

#4, TYPE 3 REINFORCEMENT AT 12" C/C

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text

(4) #5 LONGITUDINAL BAR

AutoCAD SHX Text 10"

AutoCAD SHX Text

COLUMN TIES SPA @ 6" VERT, TYP, SEE PLAN

AutoCAD SHX Text

#5 BARS

AutoCAD SHX Text

#4 BARS

AutoCAD SHX Text

CORNER REINFORCING EACH FACE, TYP

AutoCAD SHX Text

CORNER REINFORCING EACH FACE, TYP

AutoCAD SHX Text

BEYOND

AutoCAD SHX Text

#4 BARS

AutoCAD SHX Text

#5 BAR W/ HOOK

AutoCAD SHX Text *607.73607.73

AutoCAD SHX Text *608.01608.01

AutoCAD SHX Text *607.89607.89

AutoCAD SHX Text *607.61607.61

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

SIDEWALK, SEE CIVIL PLANS

AutoCAD SHX Text

SIDEWALK, SEE CIVIL PLANS

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 8"

AutoCAD SHX Text 4"

AutoCAD SHX Text

1" EXPANSION JOINT

AutoCAD SHX Text

1" EXPANSION JOINT

AutoCAD SHX Text

ODOT TYPE 3 WATERPROOFING

AutoCAD SHX Text

ODOT 705.22 TYPE B BITUMINOUS JOINT SEAL, 12" WIDE

AutoCAD SHX Text

ODOT TYPE 3 WATERPROOFING

AutoCAD SHX Text

ODOT TYPE 3 WATERPROOFING

AutoCAD SHX Text

ENSURE POSITIVE DRAINAGE FROM BIKE RACK AREA

AutoCAD SHX Text

*SEE CIVIL PLANS FOR FINAL GRADES

AutoCAD SHX Text

AutoCAD SHX Text

T/BENCH

AutoCAD SHX Text

EL = 609.67

AutoCAD SHX Text

AutoCAD SHX Text

T/BENCH

AutoCAD SHX Text

EL = 609.67

AutoCAD SHX Text

T/BIKE RACK

AutoCAD SHX Text

EL = 609.67

AutoCAD SHX Text

T/BIKE RACK

AutoCAD SHX Text

EL = 609.67

AutoCAD SHX Text

AutoCAD SHX Text *607.85607.85

AutoCAD SHX Text *607.75607.75

AutoCAD SHX Text

PROVIDE #5 CORNER REINFORCING AT ALL CORNERS. MATCH HORIZONTAL BAR SPACING.

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text

TYPICAL WALL CORNER REINFORCING

AutoCAD SHX Text

SCALE: 3/4" = 1'-0"

AutoCAD SHX Text

SEE WALL DETAILS FOR ADDITIONAL REINFORCING

AutoCAD SHX Text

(PLAN VIEW - CORNER SHOWN; 'T' INTERSECTIONS SIMILAR.)

OPTIONAL CONSTRUCTION…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .