25012_Fire_Station_4_-_Bid_Set_06-03-26.pdf
PDF 8 MB Posted
- Attached to
- Kitchen Renovations at Fire Station 4
- Solicitation number
- 2026-RFP-087
- Issued by
- Polk County, Florida
About this file
This is a bid set of architectural and engineering construction documents for the City of Lakeland's Kitchen Renovations Project at Fire Station 4, located at 215 N. Brunnell Parkway, Lakeland, Florida 33815. The project involves comprehensive kitchen renovation work within an operating fire station that remains open 24/7 for emergency operations. The scope of work includes demolition of existing kitchen facilities, installation of new flooring (Marmoleum), suspended acoustical ceiling systems, wall finishes, millwork cabinetry, plumbing fixtures, mechanical systems, electrical infrastructure, and associated site work. The renovation encompasses approximately 1,000 square feet across the kitchen and adjacent day room areas, with work phased to maintain continuous access for fire apparatus and maintenance vehicles. The bid set was issued September 15, 2025, with revisions dated March 23, 2026 and April 21, 2026. The project is designed to comply with Florida Building Code Eighth Edition (2023), NFPA standards, and applicable accessibility requirements. Key equipment to be installed includes a Greenheck range hood with inline fan, Hoshizaki undercounter ice maker, General Electric refrigerator and dishwasher, and various plumbing fixtures including an Elkay water cooler with bottle filler and single-compartment sink with garbage disposal.
The construction documents specify that the general contractor must be Florida State Certified as either a Licensed General Contractor (CGC) or Building Contractor (CBC). All work must coordinate with the Owner's separate contracts for fire alarm and fire protection modifications. The contractor is responsible for dust control, protection of existing systems and furnishings, removal and disposal of demolition debris, and restoration of all surfaces damaged during construction. Existing mechanical systems, including the split DX unit air handler, will remain operational during renovation and must be rebalanced to specified airflow rates of 1,150 CFM supply and 175 CFM return. The kitchen hood system requires rebalancing to 390 CFM exhaust flow. Plumbing work includes installation of a grease interceptor, new water lines, sanitary connections, and hot water mixing valve. Electrical work encompasses new LED lighting fixtures with occupancy sensors, power outlets for equipment, and under-cabinet lighting. The contractor must submit a certified test and balance report upon completion and maintain as-built drawings throughout construction. The project requires compliance with all Florida permitting requirements and coordination with Owner personnel to avoid disruption to station operations.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIST OF DRAWINGS
COVER
COVR COVER SHEET
ARCHITECTURAL
C101 OVERALL ARCHITECTURAL SITE PLAN
D101 DEMOLITION FLOOR PLAN AND DEMOLITION REFLECTED CEILING PLAN
A001 LIFE SAFETY PLAN
A101 FLOOR PLAN AND AND REFLECTED CEILING PLAN
A801 MILLWORK SECTIONS AND DETAILS
SP101 SPECIFICATION
SP102 SPECIFICATION
SP103 SPECIFICATION
SP104 SPECIFICATION
SP105 SPECIFICATION
MECHANICAL
M101 MECHANICAL NOTES, SCHEDULES AND LEGEND
M201 MECHANICAL FLOOR PLAN
PLUMBING
P101 PLUMBING NOTES, SCHEDULES AND LEGEND
P201 PLUMBING FLOOR PLANS
P301 PLUMBING DETAILS
ELECTRICAL
E101 ELECTRICAL GENERAL NOTES & SYMBOL LEGEND
E201 ELECTRICAL DEMOLITION PLAN
E301 LIGHTING PLAN
E401 POWER & SYSTEMS PLAN
DRAWING NOTE
WALL SECTION
DRAWING REFERENCE
DETAIL
DRAWING REFERENCE
CENTERLINE
DOOR NUMBER
WINDOW TYPE
ROOM NAME / NUMBER
UNO UNLESS NOTED OTHERWISE
DO NOT SCALE THESE DRAWINGS
SYMBOL LEGEND
FRAME NUMBER
MILLWORK SYMBOL
Room Name
BUILDING SECTION
DRAWING REFERENCE
M1
XXX
A
1i
A501
AA
A101A101
A501
AA
BUILDING DESIGN CRITERIABUILDING DESIGN CRITERIA
FLORIDA BUILDING CODE (FBC) EIGHTH EDITION (2023)
ASCE 7-22
FBC-MECHANICAL EIGHTH EDITION (2023)
FBC-PLUMBING EIGHTH EDITION (2023)
FBC-FUEL GAS EIGHTH EDITION (2023)
FBC-ACCESSIBILITY EIGHTH EDITION (2023)
FBC-ENERGY CONSERVATION EIGHTH EDITION (2023)
NATIONAL ELECTRIC CODE (NEC) 2023 - NFPA 70
FLORIDA FIRE PREVENTION CODE (FFPC) EIGHTH EDITION (2023)
NFPA 1 2021
NFPA 101 2021
DESIGN WIND SPEED: 140 MPH X 1.0 IF
DESIGN LOAD FOR COMPONENTS & CLADDING: N/A
DESIGN DATA
CONSTRUCTION TYPE
FBCFBC
COMPLIANCE STATEMENT
TO THE BEST OF THE ARCHITECT'S KNOWLEDGE, THESE DRAWINGS AND
THE PROJECT SPECIFICATIONS ARE COMPLETE AND COMPLY WITH THE
REFERENCED CODES.
CODE CONFORMANCE
OCCUPANCY GROUP S-1 MODERATE HAZARD
STORAGE
LODGING/ STORAGE - ORDINARY
HAZARD
TYPE II-B, UNPROTECTED WITH
FIRE SPRINKLER SYSTEM
PROJECT LOCATION
CONSTRUCTION
CHECKED BY
REVIEW
APPROVAL
REVISIONS
LA
KE
LA
ND
, F
LO
RI
DA
3-
JO
HN
R . C
UR
TI
S, AI
A
BE
NJ
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
RI
AV
EN
UE
3- 8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:43:59 PM Z:\0000_Revit\25012_LFD No4_Kitchen Renno_Neil.rvt
K
IT
C H E N R E N O V A T
IO
N
L F D S T A T
IO
N N O
N B R
UN
N E L L P K W Y
L A K E L A N D F L
C O V
ER
S
HE
ET
COVR
25012
09/15/25
03/23/26
04/21/26
KITCHEN RENOVATION
215 N. BRUNNELL PKWY.
LAKELAND, FL 33815
LFD - STATION NO. 4
AR
NE
IL
G . M
EL
B Y
New Power Consulting Inc. Consulting Electrical Pyramid Engineering Inc. Consulting Mechanical And Plumbing Engineer
CMHMCMHM ARCHITECTSARCHITECTS ARCHITECT
N
VICINITY MAP
NO SCALE
OWNEROWNER
CITY OF LAKELAND
228 S. MASSACHUSETTS AVENUE
LAKELAND, FLORIDA 33801
PROJECT ADDRESS
215 N. BRUNNELL PKWY.
LAKELAND, FL 33815
ARCHITECT OF RECORDARCHITECT OF RECORD
NEIL GENE MELBY, AIA
STATE OF FLORIDA REG. No. AR94375
B R
UN
N E L L P
A R
K W
A Y
EXISTING FIRE
STATION No.4
EXISTING
STORAGE BUILDING
E X
IS
T
IN
G C
O N C R
E T E
G A T E
AREA
OF
WORK
FIRE DEPARTMENT
ACCESS
FIRE DEPARTMENT ACCESS
DO NOT BLOCK
LAY DOWN AREA
CONSTRUCTION
CHECKED BY
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:18 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
O
N B
R
UN
N E L L P
K W
Y
L A K E L A N D
F L
O V
ER
A
LL
A R
C
HI
TE
C
TU
R A L
SI
TE
P
LA
N
C101 25012
AR
NE
IL
G . M
EL
B
Y
09/15/25
03/23/26
04/21/26
1" = 20'-0"
ARCHITECTURAL SITE PLANARCHITECTURAL SITE PLAN
C101 Sheet Notes / Numbers May Not Be Consecutive.
201 Existing backflow preventer on concrete pad.
202 Existing retention pond.
203 Existing asphalt paving and parking.
204 Existing 6 ft. high chain link fencing with barbed wire top.
205 Line of building.
206 Existing grass/landscaping.
207 Existing covered pressure washer.
208 Existing concrete steps and walls.
209 Contractor may utilize these asphalt pavement parking spaces for their use for duration of construction.
210 Grease separator. See Plumbing Drawings.
211 Existing concrete pad with condensing units and associated equipment.
212 Remove existing tree in its entirety; including roots. Fill and smooth grade as required and sod/mulch all disturbed areas.
Contractor shall coordinate all tree removal and exterior work with the Owner. Maintain continuous access for fire apparatus and maintenance vehicles at all times.
213 Existing concrete sidewalk to be demolished for sanitary line work. Replace sidewalk to match existing conditions.
217 Existing 6 ft. high chain link fencing with barbed wire top to remain.
NN
FACILITY IS OPEN 24/7 FOR EMERGENCY
OPERATIONS.
ALL WORK SHALL BE COORDINATED WITH
THE OWNER TO MAINTAIN ACCESS TO THE
STATION AND MAINTENANCE FACILITY.
UP
DAY ROOM
KITCHEN
HALL
SERVICE
CLOSET
BATH
DATA
OFFICERS
STAIRS
UTILITY
CLOSET
TV
FE
FMB
A R E A O F W O R K
OWNER WILL REMOVE AND STORE
EXISTING FURNITURE AND OFFICE
EQUIPMENT FROM AREA TO BE
RENOVATED PRIOR TO CONSTRUCTION
A101
S
S
S
F H
S
F H
WIFI
A R E A O F W O R K
7' - 10"
REFLECTED CEILING PLAN LEGENDREFLECTED CEILING PLAN LEGEND
(THIS LEGEND APPLIES TO THIS SHEET ONLY)
EXISTING SUSPENDED GRID WITH CEILING TILES TO BE REMOVED.
EXISTING LIGHT FIXTURE TO BE REMOVED.
0'-0"
REMOVE RECESSED LIGHT FIXTURE.
CEILING HEIGHT AS NOTED
FIRE ALARM DEVICE. REMOVAL AND RELOCATION BY OWNER.
EXISTING HVAC SUPPLY DIFFUSER TO BE REMOVED. SEE MECHANICAL
DRAWING.
EXISTING HVAC RETURN EXHAUST/ GRILLE TO BE REMOVED. SEE
MECHANICAL DRAWINGS.
EXISTING FIRE PROTECTION SPRINKLER HEAD TO REMAIN.
SMOKE DETECTOR. REMOVAL AND RELOCATION BY OWNER.S
S SPEAKER. REMOVAL AND RELOCATION BY OWNER.
WIFI EXISTING WIFI DEVICE. REMOVAL AND RELOCATION BY OWNER.
F H
A. Existing building information as shown and described in these documents has been developed from the architect's field observations and field measurements. This in no way relieves the Contractor of the responsibility to determine existing conditions, construc-tion details, measurements, etc. Contractor shall review existing conditions and determine appropriate coordination of new work as described prior to commencement of any demolition or other work.
B. Owner assumes no responsibility for actual condition of structures to be demolished. Conditions existing at time of inspection for Bidding purposes will be maintained by Owner to fullest extent possible, unless noted otherwise.
C. Scope of demolition and construction work has been described to fullest extent possible, however this does not relieve Contractor of responsibility to perform all incidental associated work to patch/ refinish exposed finished surfaces (and trim) and provide complete operational systems. Patching/refinishing work shall include all blemishes and holes created by demolition and construction work as well as existing obvious damaged surfaces and materials.
D. Contractor shall remove electrical conduit, conductors, devices and miscellaneous items as described in the documents. Main power distribution and electrical panels shall remain, be reworked as required, and be maintained throughout duration of construction project.
E. All abandoned plumbing, mechanical and electrical items shall be removed, and where concealed and inaccessible within existing construction shall be removed and capped below adjacent finish surfaces. Abandoned items shall be removed in their entirety.
F. General contractor is fully responsible for coordination of cutting, patching and refinishing of all structural elements and finish surfaces damaged/revealed by demolition and construction activities. The intent is that applicable construction or finish trades perform all patching and refinishing work to match adjacent surfaces.
G. Contractor shall ensure safe passage of persons around demolition area and conduct operations to prevent injury. Contractor shall also protect from damage all existing adjacent walls, furniture, floor material and other misc. items during the construction process. All damaged items/ surfaces shall be replaced or repaired to match existing and to the satisfaction of Owner/ Architect.
H. Contractor is responsible for all means necessary to control construction dust during construction/demolition operations to prevent dust from spreading to other areas, contaminating existing mechanical systems, etc. Any areas damaged or items contaminated with construction dust shall be thoroughly cleaned (or replaced if necessary) to Owner's satisfaction.
NOTE: Existing mechanical systems are intended to remain in place during construction activities. Contractor shall affix temporary filter media across the face of all active return air grilles, changing often, to prevent dust contamination of existing operational duct system.
J. Turn over salvaged items to owner as noted. All other items and debris to be removed shall be disposed of off site.
K. Remove flooring, floor base, and ceiling fixtures/ devices as scheduled.
Light fixtures shall be disposed of all other ceiling devices shall be removed, stored and protected for re-installation.
GENERAL DEMOLITION NOTES:
GENERAL RENOVATION SCOPE OF WORK/NOTES:
1. Remove existing and provide new flooring as scheduled.
2. Remove existing and provide new suspended acoustical ceiling system as scheduled.
3. Repaint interior area of work throughout as noted and scheduled.
4. Replace HVAC devices as noted and detailed.
5. Replace light fixtures in suspended acoustical ceiling as noted.
6. Rework/replace plumbing lines as noted and detailed.
7. Owner to occupy facility during renovation. Contractor shall protect all furnishings, appliances, and supplies stored on site.
CONSTRUCTION
CHECKED BY
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:19 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
O
N B
R
UN
N E L L P
K W
Y
L A K E L A N D
F L
D
EM
O
LI
TI
O
N P
LA
N S
D101 25012
AR
NE
IL
G . M
EL
B
Y
09/15/25
03/23/26
04/21/26
1/4" = 1'-0"
DEMOLITION FLOOR PLANDEMOLITION FLOOR PLAN
1/4" = 1'-0"
DEMOLITION REFLECTED CEILING PLANDEMOLITION REFLECTED CEILING PLAN
D101 Sheet Notes / Numbers May Not Be Consecutive.
101 Demolish existing drywall over furring on concrete block wall construction to limits shown. Patch and/or rework concrete slab finish to accommodate new floor finish.
102 Remove existing appliances and cabinets in their entirety.
103 Remove existing grid and ceiling tiles.
104 Remove existing wall mounted water fountain and cap plumbing. See Plumbing Drawings.
106 Remove and reinstall existing refrigerator.
107 Remove existing sink and cap plumbing behind wall finish and patch to match existing.
108 Remove existing flooring in its entirety. Prepare concrete slab for scheduled finish.
204 Existing 6 ft. high chain link fencing with barbed wire top.
208 Existing concrete steps and walls.
211 Existing concrete pad with condensing units and associated equipment.
212 Remove existing tree in its entirety; including roots. Fill and smooth grade as required and sod/mulch all disturbed areas. Contractor shall coordinate all tree removal and exterior work with the Owner. Maintain continuous access for fire apparatus and maintenance vehicles at all times.
213 Existing concrete sidewalk to be demolished for sanitary line work. Replace sidewalk to match existing conditions.
214 Existing 6 ft. high chain link fencing with barbed wire top to be demolished for sanitary line work.
Replace fencing to match existing conditions.
301 Saw cut and remove existing concrete slab to general limits indicated as coordinated with plumbing drawings. Compact subgrade to underside of existing slab and infill slab with concrete over 10 mil. vapor barrier and finish to match existing.
1002 Owner relocate existing fire extinguisher and wall hook. Owner shall service fire extinguisher and provide up to date certification tag with a remaining 12 months.
1003 Remove existing markerboard and patch and refinish wall finish damaged by markerboard removal. Salvage and turn markerboard over to Owner.
NN
NN
REFER TO ACT ENVIRONMENTAL & INFRASTRUCTURE
REPORT FOR ASBESTOS REMOVAL.
LIFE SAFETY LEGENDLIFE SAFETY LEGEND
SURFACE MTD. EMERGENCY LIGHT
COMBO EXIT/EMERGENCY LIGHT
FIRE ALARM MANUAL PULL STATION BY OWNER.
CEILING FIRE ALARM HORN & STROBE LIGHT BY OWNER.
FIRE EXTINGUISHER (Wall bracket mounted)
F
F
FE
FARA FIRE ALARM PANEL BY OWNER.
G.C. TO PROVIDE FIRE ALARM CONNECTION TO HOOD
ANSUL SYSTEM. COORDINATE WITH OWNER.R
KITCHEN
DAY ROOM
F
FE
42' TRAVEL
(125' MAX)
E X
IT
F
FARA
R
CONSTRUCTION
CHECKED BY
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:15 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O V A
TI
O N
L F D S
T A T
IO
N N
O
N B R
UN
N E L L P
K W Y
L A K E L A N D F L
LI
FE
S A
FE
TY
A001 25012
AR
NE
IL
G
. M
EL
B Y
09/15/25
03/23/26
04/21/26
1/4" = 1'-0"
LIFE SAFETY PLANLIFE SAFETY PLAN
NOTE:
FIRE ALARM AND FIRE SPRINKLER WORK BY OWNER UNDER SEPARATE
CONTRACT. CONTRACTOR SHALL COORDINATE ALL FIRE ALARM AND
FIRE SPRINKLER RELATED WORK WITH OWNER. THIS INCLUDES KITCHEN
HOOD.
NN
A001 Sheet Notes / Numbers May Not Be Consecutive.
1002 Owner relocate existing fire extinguisher and wall hook. Owner shall service fire extinguisher and provide up to date certification tag with a remaining 12 months.
C A B I N E T S
7' - 10"
WIFI
A R E A O F W O R K
S
S
S
F
S o
7' - 0"
P A N T R
Y R
A N G
E
H O
O D
6'-4"
1' - 6"
R E F
R E F
P A
N T
R Y
DW
DISPOSAL
2' 6"
3'
3'
4' - 0"
2x2
DAY ROOM
KITCHEN
HALL
SERVICE
CLOSET
STAIRS
A R E A O F W O R K
D E
S K
T A B L E
R E F
ICE
MAKER
TV
M2
M1
EX
EX
FE 12M3
EX EX
E X
IS
T
IN
G F L O
O R
IN
G
N E W
F L O
O R
IN
G
C J
T J
T J
T J
HALL
0'-0"
NEW LED LIGHT FIXTURE SET IN GRID.
NEW SURFACE MOUNTED EXIT/EMERGENCY LIGHT
CEILING HEIGHT AS NOTED
NEW HVAC SUPPLY DIFFUSER
NEW HVAC RETURN EXHAUST/ GRILLE
NEW OCCUPANCY SENSOR. SEE ELECTRICAL DRAWINGS.o
REFLECTED CEILING PLAN LEGENDREFLECTED CEILING PLAN LEGEND
(THIS LEGEND APPLIES TO ALL CEILING PLANS)
NEW 2'-0' x 2'-0" SUSPENDED GRID WITH CEILING TILES.
EXISTING FIRE PROTECTION SPRINKLER HEAD
GENERAL CONSTRUCTION NOTES
S SPEAKER. REMOVAL AND RELOCATION BY OWNER.
WIFI EXISTING WIFI DEVICE. REMOVAL AND RELOCATION BY OWNER.
1. INTENT IS TO UTILIZE EXISTING FIRE PROTECTION SPRINKLER HEAD
LOCATIONS TO GREATEST EXTENT POSSIBLE, PROVIDE NEW HEADS
AND RELOCATE EXISTING AS NECESSARY. FIRE SPRINKLER MODIFICATIONS
AND DESIGN/ PERMITTING ARE BY OWNER UNDER SEPARATE CONTRACT.
2. HVAC EQUIPMENT, DUCTS, AND DEVICES LAYOUT ARE SCHEMATIC
AND MAY NOT REPRESENT EXACT FIELD CONDITIONS. DEVIATIONS
FROM LAYOUT SHOWN, WHICH MAY BE VERIFIED DURING THE BID
PROCESS, WILL NOT PROVIDE CAUSE FOR ADDITIONAL COMPENSATION
DURING THE CONSTRUCTION PROCESS. CONTRACTORS SHALL VISIT
THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS INVOLVING
THE WORK.
3. HVAC SYSTEMS SHALL BE PROTECTED FROM DUST INFILTRATION
AND REMAIN FULLY FUNCTIONAL DURING CONSTRUCTION.
4. MECHANICAL CONTRACTOR SHALL MODIFIY EXISTING DUCTWORK
AND RE-BALANCE AIR FLOW IN RENOVATED SPACES.
5. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL
MINOR ITEMS WHICH ARE REASONABLEY NECESSARY TO COMPLETE
THE INSTALLATION WHETHER OR NOT SPECIFIED AS SHOWN ON PLANS.
6. ALL WORK SHALL MEET ALL THE REQUIREMENTS OF THE "FLORIDA
BUILDING CODE, 8TH EDITION 2023".
7. CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE IN ALL RESPECTS
ALL LIGHTING FIXTURES SHOWN AS NEW.
8. ALL LIGHTING FIXTURES SHALL BE PROPERLY SUPPORTED. CONTRACTOR
SHALL FURNISH AND INSTALL ALL NECESSARY SUPPORT WIRES AND TRIM.
9. CONTRACTOR SHALL FURNISH AND INSTALL OCCUPANCY SENSORS AS REQUIRED.
SUBMIT SHOP DRAWINGS SHOWING LOCATIONS OF PROPOSED UNITS AND
CUT SHEETS FROM ALL DEVICES. ALL WALL MOUNTED SWITCHES SHALL OVERRIDE
"OFF" OCCUPANCY SENSOR CONTROL.
10. ALL WORK SHALL BE PROPERLY AND CAREFULLY EXECUTED IN A WORKMAN
LIKE MANNOR.
11. PROVIDE NEW POWER WHIPS TO ALL NEW LIGHT FIXTURES AND CONNECT TO
EXISTING LIGHTING CIRCUIT.
12. REMOVE ALL ASSOCIATED LIGHT SWITCHES, RECEPTICALS, CONDUIT AND THE
LIKE IN WALLS TO BE DEMOLISHED, TYPICAL.
RECESSED LIGHT FIXTURE
FIRE ALARM HORN & STROBE LIGHT BY OWNER.F
1. FIRE PROTECTION MODIFICATIONS AND DESIGN/PERMITTING ARE
BY OWNER UNDER SEPARATE CONTRACT. SEE SHEET A001 FOR FIRE
SPRINKLER SPECIFICATIONS.
2. INTENT IS TO UTILIZE EXISTING FIRE PROTECTION SPRINKLER HEAD
LOCATIONS TO GREATEST EXTENT POSSIBLE, PROVIDE NEW HEADS
AND RELOCATE EXISTING AS INDICATED.
FIRE PROTECTION PROJECT NOTES:
1. FIRE ALARM MODIFICATIONS AND DESIGN/PERMITTING ARE BY OWNER
UNDER SEPARATE CONTRACT.
FIRE ALARM PROJECT NOTES:
F
IN
IS
H E D
W A L L
PROVIDE TWO (2) HANGER WIRES AT DIAGONAL CORNERS OF TYPICAL
LIGHT FIXTURES, HVAC DIFFUSERS/ GRILLES, SPEAKERS, AND THE LIKE
INSTALLED IN SUSPENDED CEILING SYSTEM.
G.C. TO RE-HANG EXISTING LOW-VOLTAGE WIRING ABOVE CEILING AS
REQUIRED TO MEET CODE REQUIRMENTS.
(ACOUSTICAL CEILLING TILE NOT SHOWN)
CAULK CEILING GRID
TO WALL; TYPICAL
STRUCTURE ABOVE
EPOXIED SET 16" LONG #5 BARS;
4" MIN. INTO EXISTING CONCRETE
SLAB AT 34" o.c. STAGGERED
EACH SIDE. 313
CONSTRUCTION
CHECKED BY
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:16 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
O
N B
R
UN
N E L L P
K W
Y
L A K E L A N D
F L
FL
O
O R
P
LA
N A
N D
R
EF
LE
C
TE
D C
EI
LI
N G
P
LA
N
A101 25012
AR
NE
IL
G . M
EL
B
Y
09/15/25
03/23/26
04/21/26
1/4" = 1'-0"
PROPOSED REFLECTED CEILING PLANPROPOSED REFLECTED CEILING PLAN
1/4" = 1'-0"
PROPOSED FLOOR PLANPROPOSED FLOOR PLAN
A101 Sheet Notes / Numbers May Not Be Consecutive.
208 Existing concrete steps and walls.
210 Grease separator. See Plumbing Drawings.
211 Existing concrete pad with condensing units and associated equipment.
217 Existing 6 ft. high chain link fencing with barbed wire top to remain.
218 Existing landscape bed.
302 Infill concrete walk slab where removed for plumbing work: 4" thick concrete with
6x6-W1.4x W1.4 WWF over 10 mil poly vapor barrier over termite treated compacted earth/ grade; typical. Provide cold construction joints (CJ) and tooled control joints (TJ) or saw cut control joints (SJ) as indicated. Provide with light broom finish;
typical (UNO).
303 Existing concrete walk; typical.
619 8 in. diameter countertop trash opening.
802 Existing door and door frame to remain. Protect from damage.
905 Termination strip between existing and new flooring.
906 Rework/ replace existing ceiling grid; wall molding and ceiling tiles as necessary after removal of wall mounted cabinet.
1002 Owner relocate existing fire extinguisher and wall hook. Owner shall service fire extinguisher and provide up to date certification tag with a remaining 12 months.
1101 Undercounter ice maker. Refer to equipment schedule.
1102 Refrigerator. Refer to equipment schedule.
1103 36 in. range with hood. Refer to equipment schedule and mechanical drawings.
1105 Dishwasher. Refer to equipment schedule.
1106 Wall mounted hi-lo ADA water fountain with bottle filler. Refer to plumbing drawings.
1107 Range hood. Provide stainless steel enclosure above to soffit.
1108 Coffee by owner.
1110 Counter top microwave provided by Owner.
1201 Install owner provided TV bracket and TV to wall.
1202 Furnishings by owner.
1503 Existing water heater.
1504 Existing air handler unit.
1603 Existing electrical panel.
1604 Electrical panel. Refer to Electrical Drawings.
1605 Under cabinet lighting.
1 1/2" = 1'-0"
TYPICAL SUSPENDED CEILING DETAILTYPICAL SUSPENDED CEILING DETAIL
NN
NN
3/4" = 1'-0"A101A101
44 TYPICAL CONCRETE FLOOR INFILL DETAILTYPICAL CONCRETE FLOOR INFILL DETAIL
M1
SOUTH EASTKITCHEN (102)
2' - 6" 3' - 0" 2' - 6" 2' - 0"
1'
7'
2' - 0" 2' - 0" 2' - 0"
7'
DR
1'
1601 603 606
601 1103 605
901 601
TYP. 902
DR
NORTH
2' - 0"2' - 10" 2' - 10" 2' - 10" 2' - 10"
DR
SINK
2' - 10" 2' - 10" 2' - 10" 1' - 6" 6"
4 5
1'
- 2
6' 8"7'
903 904
DR
DR
DR
DR DR
DR
11092A
903 903
DR
DR
9"
M2
NORTHSOUTHKITCHEN (102)
1' - 6" 3" 3' - 0" 3" 2' - 0"
SINK
DISH
WASHER
3' - 0"
10"
2' - 4" 2' - 4" 2' - 4"
901 TYP.
EASTWEST
3'
"ICE
MAKER
3' - 0"
1'
- 8
1'
- 4 " 10"
1'
- 8
1'
- 4
1101 1501 621 621 621 621
5"
2' - 2"2' - 0" 3"
7"
3"
2A
1" 2' - 2"
3"
7"
610603
TYP.
2' - 0" 3"
7"
3"
1'
1" 1' - 0"
610603
1'
2' - 0" 3"
1'
1" 1' - 0"
2' - 0" 1' - 0"
2' - 0"
1" 1' - 0"
903 904
7'
7'
7'
904 904
7'
1502 1501
3'
1'
- 6
2' 6"
7'
901 613
2' - 0" 3"
7"
N D
A
E
Q
UA
L D
R A W
E R
S TYP.
10" 7"
1' - 1" 1' - 1"1' - 1"2' - 3"
1"
SUSPENDED
CEILING
UPPER WALL
CABINET
5/8" THICK
DRYWALL
C-CHANELS
1" THICK RIGID
INSULATION.
5/8" THICK DRYWALL
ON METAL FURRING
AT 16" O.C.
EXISTING BLOCK
WALL
METAL STUDS
SEE MILKWORK SECTIONS FOR DIMENSION
MARK
EQUIPMENT SCHEDULE
DESCRIPTIONQTY
MFR MODEL EQUIPMENT REMARKSVENDOR
MARK
ICE MACHINE
DISH WASHER
RANGE HOOD
1 RANGE
GENERAL ELECTRIC PDT715SYNFS 24"D X 23.75"W X 34"H
PROVIDED BY INSTALLED BY
CONTRACTOR SHALL COORDINATE
PURCHASE OF EQUIPMENT WITH
OWNER.
OWNER CONTRACTOR
ELECTROLUX ECFI3668AS
OWNER
OWNER
OWNER
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR
HOSHIZAKI C-80BAK 22 5/8"D X 14 7/8"W X 33 1/2"H
GREENHECK GRRS-36
REFRIGERATOR GTE21GTHSS GENERAL ELECTRIC
19.38 "D X 35.875"W X 10.5"H
24 13/16"D X 35 15/16"W X 36 9/16"H
32 1/4"D X 32 7/8"W X 66 3/4"H
1 OWNER CONTRACTORCOUNTERTOP MICROWAVE OVEN JES2251SJ GENERAL ELECTRIC 19 13/32"D X 24 1/11"W X 13 25/32"H
1 OWNER CONTRACTORGARBAGE DISPOSAL PREMIER MODEL ¾ HPIN SINK ERATOR
CONTRACTOR
ICE FILTER OWNER CONTRACTOR1
SUSPENDED CEILING
5/8" THICK DRYWALL
EXISTING RIGID
INSULATION.
EXISTING 5/8" THICK
DRYWALL ON METAL
FURRING.
EXISTING BLOCK
WALL
METAL STUDS
36" RANCGE HOOD
C-CHANELS
SELF-ADHERING FLEXIBLE MEMBRANE FLASHING
NEW WALL LOUVER
SEE MECH. DWGS.
RE-CONSTRUCT EXISTING CMU WALL
CONSTRUCTION AS NECESSARY TO
INSTALL NEW WALL LOUVER.
F I E
L D
V
R
I F
Y
REFER TO KITCHEN HOOD MANUFACTURE'S INSTALLATION
INSTRUCTIONS. CONTRACTOR SHALL FURNISH AND INSTALL
ALL MINOR ITEMS WHICH ARE REASONABLEY NECESSARY
TO COMPLETE THE INSTALLATION WHETHER OR NOT SPECIFIED
AS SHOWN ON PLANS.
SEAL LOUVER TO SPLIT FLUTED
BLOCK WATER TIGHT.
SAW CUT AND REMOVE EXISTING CMU
WALL CONSTRUCTION ABOVE LOUVER
AS NECESSARY TO INSTALL NEW LOUVER.
WEST
3'
1'
- 6
2' 6"
7'
M3 NORTH
2' 6"
1'
- 6
3'
6' 8"
2' - 3" 1' - 0"
1' - 0"
24 GAUGE 304 STAINLESS
STEEL SCRATCH PLATE
24 GAUGE 304 STAINLESS
STEEL SCRATCH PLATE
FINGER SPRING LATCH
FINGER SPRING LATCH
STORAGE CABINET DOOR
DRILL 3/8" HOLE TO ACCEPT
PADLOCK REQUIRED AT EACH
PULL. ONE PER DOOR
DOOR PULL - LET IN TO
DOOR EDGE
CONSTRUCTION
CHECKED BY
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:17 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
O
N B
R
UN
N E L L P
K W
Y
L A K E L A N D
F L
M
IL
LW
O
R K E
LE
V
A
TI
O N S
A N D
D
ET
A
IL
S
A801 25012
AR
NE
IL
G . M
EL
B
Y
09/15/25
03/23/26
04/21/26
A801 Sheet Notes/ Numbers May Not Be Consecutive.
601 24 in. deep base cabinet. Construct of 3/4 in. thick plywood with one adjustable shelf and one 6 in. deep drawer. Cover all exposed surfaces with L.P.
602 12 in. deep upper wall cabinet. Construct of 3/4 in. thick plywood with doors and two adjustable shelves. Cover all exposed surfaces with L.P.
603 Solid surface countertop with matching 4 inch high side and backsplash.
604 Support bracket.
605 24 in. deep base cabinet with 4 drawers. Cover all exposed surfaces with L.P.
606 Stainless steel backsplash.
608 26 in. deep storage cabinet. Construct of 3/4 in. thick plywood with adjustable shelves and doors. Provide lockable doors where shown. Coverall exposed surfaces with L.P.
609 3/4 in. thick plywood panels. Cover all exposed surface with L.P.
610 6 in. deep drawer. Construct of 1/2 in. thick solid stock with hardboard bottom and heavy duty glides.
611 Recessed shelf standards.
612 3/4 in. thick plywood adjustable shelf. Cover all exposed surfaces with L.P.
613 2x4 P.T. wood base.
614 3/4 in. thick plywood door. Cover all exposed surfaces with L.P.
615 Hardboard back.
616 3/4 in. thick plywood fixed shelf. Cover all exposed surfaces with L.P.
617 3/4 in. thick plywood underlayment.
618 12 in. deep base cabinet. Construct of 3/4 in. thick plywood with one adjustable shelf. Cover all exposed surfaces with L.P.
620 12 in. deep wall-mounted open shelf . Construct of 3/4 in. thick plywood with one fixed shelf as shown. Cover all exposed surfaces with L.P.
621 Solid surface countertop.
622 12 in. deep base cabinet. Construct of 3/4 in. thick plywood with two adjustable shelves. Cover all exposed surfaces with L.P.
623 Solid surface backsplash.
901 Continuous base.
902 Ceramic tile backsplash.
903 27 in. deep soffit above storage cabinets.
904 13 in. deep soffit above upper cabinets.
1101 Undercounter ice maker. Refer to equipment schedule.
1102 Refrigerator. Refer to equipment schedule.
1103 36 in. range with hood. Refer to equipment schedule and mechanical drawings.
1105 Dishwasher. Refer to equipment schedule.
1107 Range hood. Provide stainless steel enclosure above to soffit.
1109 Garbage can by owner.
1501 Single bowl sink with garbage disposal.
1502 Single bowl sink.
1505 Wall louver beyond. Contractor to coordinate millwork and soffit framing with wall louver opening for kitchen hood exhaust. See mechanical drawings.
1601 Power/data outlet. Refer to Electrical Drawings.
1602 Under Cabinet Lighting. Refer to Electrical Drawings.
3/4" = 1'-0"
MILLWORK SECTIONSMILLWORK SECTIONS
Room Finish ScheduleRoom Finish Schedule
Rm. No.Rm. No. Room NameRoom Name FloorFloor BaseBase WallWall CeilingCeiling RemarksRemarks
101 DAY ROOM MMT RC PEDW SAG (1) (3)
102 KITCHEN MMT RC PEDW/CT SAG (1) (3) (4) (5)
103 HALL MMT RC PEDW EX (1) (2) (3)
REMARKS:
(1) PATCH WALLS AS REQUIRED AND RE-TEXTURE TO MATCH
EXISTING AND PAINT GYPSUM DRYWALL.
(2) INSTALL TERMINATION STRIP AT NEW TO EXISTING FLOOR.
TYPICAL.
(3) THOROUGHLY CLEAN CONCRETE AS RECOMMENDED BY
MMT MANUFACTURER USING ALL NECESSARY MEANS
TO REMOVE ALL DIRT AND GLUE COMPOUND.
(4) PAINT GYPSUM DRYWALL AT DROPPED HEADER/SOFFIT.
(5) KITCHEN BACK SPLASH TILE (CT): EMSER TILE, CATCH GLAZED
CERAMIC, 4" x 10" SIZE WITH TRIM TO MATCH. COLOR AS
SELECTED BY ARCHITECT.
ROOM FINISH SCHEDULE ABBREVIATIONS:
CT CERAMIC TILE BACKSPLASH
PEDW PAINT EXISTING PAINTED GYPSUM DRYWALL
RC 4" HIGH RUBBER COVE BASE
SAG SUSPENDED ACOUSTICAL CEILING
MMT MARMOLEUM (Forbo)
3/4" = 1'-0"
CABINET SOFIT DETAILCABINET SOFIT DETAIL 3/4" = 1'-0"
KITCHEN RANGE/HOOD DETAILKITCHEN RANGE/HOOD DETAIL
1 1/2" = 1'-0"A801A801
11 PANTRY LATCH DETAILPANTRY LATCH DETAIL
CONSTRUCTION
CHECKED BY
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:19 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
O
N B
R
UN
N E L L P
K W
Y
L A K E L A N D
F L
SP
EC
IF
IC
A
TI
O N S
SP101
25012
AR
NE
IL
G . M
EL
B
Y
09/15/25
03/23/26
04/21/26
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:19 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
O
N B
R
UN
N E L L P
K W
Y
L A K E L A N D
F L
SP
EC
IF
IC
A
TI
O N S
SP102
25012
AR
NE
IL
G . M
EL
B
Y
09/15/25
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:19 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
O
N B
R
UN
N E L L P
K W
Y
L A K E L A N D
F L
SP
EC
IF
IC
A
TI
O N S
SP103
25012
AR
NE
IL
G . M
EL
B
Y
09/15/25
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:20 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
O
N B
R
UN
N E L L P
K W
Y
L A K E L A N D
F L
SP
EC
IF
IC
A
TI
O N S
SP104
25012
AR
NE
IL
G . M
EL
B
Y
09/15/25
REVIEW
APPROVAL
LA
KE
LA
ND
, F
LO
RI
3-
JO
HN
R . C
UR
AM
IN
F . M
UN
DY
, J R.
, A
IA
LE
ED
A P
C.
K
EI
TH
H
UN
NI
CU
TT
AI
A
REVISIONS
NE
IL
G.
M
EL
BY
, A
IA
, L
EE
D AP
S
OU
TH
F
LO
8- 8 2
TE
LE
PH
ON
EC
M
HM
A
RC
HI
TE
C
TS
IN
C lkl da rch .co m
4/25/2026 1:32:20 PM F:\25012\25012_LFD No4_Kitchen Renno_Central.rvt
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
O
N B
R
UN
N E L L P
K W
Y
L A K E L A N D
F L
SP
EC
IF
IC
A
TI
O N S
SP105
25012
AR
NE
IL
G . M
EL
B
Y
09/15/25
REVIEW
APPROVAL
LA
KE
LA
N
D, F
LO
-1
JO
HN
R . C
UR
TI
S, AI
A
BE
N
JA
M
IN
F . M
UN
DY
, J R.
, A
IA
, L
EE
D
AP
C.
K
EI
TH
H
UN
N
IC
UT
T, A
IA
REVISIONS
N
EI
L G.
M
EL
BY
, A
IA
, L
EE
D
AP
SO
UT
H
FL
O
RI
DA
A
VE
N
UE
3-
8-
TE
LE
PH
O
N E
C M
HM
A
RC
HI
TE
C
TS
IN
C lk lda rc h.
co m
23012
M
IC
H A
E L
C U
R K
A N
P E
PYRAMID
ENGINEERING
04/21/26
03/23/26
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
.4
N B
R
UN
N E L L P
K W
Y L ak e la nd F L
09/15/25
M
EC
HA
N
IC
A L
N O
TE
S, S C
HE
D
UL
ES
A
N D
L
EG
EN
D
M101
AutoCAD SHX Text
(727) 531-2989 * Reg. No. EB6890
AutoCAD SHX Text 5596 Rio Vista Drive
AutoCAD SHX Text Clearwater, Florida 33760
AutoCAD SHX Text C O N S U L T I N G E N G I N E E R S
AutoCAD SHX Text pyramid@pyramidengineering.org
AutoCAD SHX Text
MECHANICAL LEGEND
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
NEW DUCTWORK, PIPING, OR EQUIPMENT
AutoCAD SHX Text
FLEXIBLE DUCT
AutoCAD SHX Text
SUPPLY OR OUTSIDE AIR DUCT SECTION
AutoCAD SHX Text
RETURN DUCT SECTION
AutoCAD SHX Text
EXHAUST DUCT SECTION
AutoCAD SHX Text
DUCTWORK TRANSITION
AutoCAD SHX Text
MANUAL AIR VOLUME CONTROL DAMPER
AutoCAD SHX Text
SUPPLY AIR DEVICE. CLEAR TRIANGLE SIDES
AutoCAD SHX Text
INDICATE AIR FLOW PATTERN
AutoCAD SHX Text
RETURN AIR DEVICE
AutoCAD SHX Text
EXHAUST AIR DEVICE
AutoCAD SHX Text
UNDERCUT DOOR 3/4"
AutoCAD SHX Text
WALL MOUNTED THERMOSTAT
AutoCAD SHX Text T
AutoCAD SHX Text MECHANICAL GENERAL NOTES: IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY THE SCOPE OF WORK AND ALERT CONTRACTOR OF EXISTING CONDITIONS. CONTRACTOR TO VISIT SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION OF DUCTWORK AND PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET FIELD CONDITIONS AND COORDINATE WITH ELECTRICAL, PLUMBING AND FIRE PROTECTION SUBCONTRACTOR BEFORE ANY CONSTRUCTION WORK. BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS INVOLVING THE WORK. SHOULD ANY CONFLICTS ARISE, THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF THE CONFLICT BEFORE ANY CHANGES ARE MADE. THE CONTRACTOR SHALL OBTAIN WRITTEN APPROVAL BEFORE PROCEEDING WITH ANY CHANGES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TRADES INSTALLATION SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND PLUMBING SHALL BE INSTALLED PRIOR TO ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR OFFSET SUCH AS ELECTRICAL CONDUITS AND SMALL WATER LINES ETC. ALL AIR CONDITIONING WORK SHALL NOT INTERFERE WITH CLEARANCES REQUIRED FOR GENERAL AND MECHANICAL CONSTRUCTION. SHOULD AIR CONDITIONING WORK BE INSTALLED WHICH INTERFERES WITH THE WORK OF OTHER CONTRACTORS. SUCH WORK SHALL BE CHANGED AT NO ADDITIONAL COST TO THE OWNER. ALL WORK COVERED IN THIS SECTION SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST PUBLISHED STANDARDS OF ASHRAE, AND NFPA. ALL MECHANICAL WORK SHALL MEET ALL THE REQUIREMENTS OF THE "FLORIDA BUILDING CODE 2023", 8th EDITION. IN THE EVENT THAT THERE IS A CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND THE CODE, THE CODE SHALL TAKE PRECEDENCE. THE MECHANICAL CONTRACTOR SHALL STUDY THE CONTRACT DOCUMENTS AND SUBMIT A BID BASED ON WORK WHICH COMPLIES WITH ALL CODE REQUIREMENTS. ANY CONFLICTS BETWEEN THE CONTRACTOR DOCUMENTS AND THE CODE SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO BID. THE COST OF ANY WORK WHICH ARISES OUT OF ANY CHANGES DUE TO CODE REQUIREMENTS SHALL BE PAID BY THE MECHANICAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL CHECK ALL EQUIPMENT FOR CORRECT VOLTAGE RATING BEFORE INSTALLATION. IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR FOR THE ADVANCE ORDERING OF LONG LEAD ITEMS SO AS NOT TO DELAY OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION WHETHER OR NOT SPECIFIED AS SHOWN ON THE PLANS. MECHANICAL CONTRACTOR SHALL ARRANGE TO PAY FOR ALL NECESSARY PERMITS, LICENSES AND INSPECTIONS AS REQUIRED BY THE CITY. TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE MINIMUM BUILDING CODES. DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. ALL CONCEALED SUPPLY AND RETURN DUCTWORK SHALL BE EXTERNALLY INSULATED SHEET METAL CONSTRUCTION IN ACCORDANCE WITH LATEST SMACNA STANDARDS, WITH GALVANIZED SHEET METAL TURNING VANES AND MANUAL WITH GALVANIZED SHEET METAL TURNING VANES AND MANUAL VOLUME DAMPERS. ALL DUCT JOINTS AND SEAMS SHALL BE SEALED AIRTIGHT WITH HARDCAST CWWI-181 DUCT SEALANT. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 8'-0". VOLUME DAMPERS WITH LOCKING QUADRANTS SHALL BE INSTALLED IN ALL DUCT BRANCHES. ALL INSULATION SHALL HAVE A MINIMUM FLAME SPREAD/SMOKE DEVELOPED RATING OF 25/50. FLEXIBLE DUCTWORK SHALL BE LOW PRESSURE FACTORY FABRICATED CONSISTING OF A ZINC-COATED SPRING STEEL HELIX, NON-PERFORATED INNER LINER AND 1" THICK FIBERGLASS R-6 INSULATION WITH METALIZED VAPOR BARRIER. COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES. ALL SUPPLY AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS OTHERWISE NOTED. INSULATE BACK PANS OF ALL DIFFUSERS. ALL WALL MOUNTED THERMOSTATS AND/OR TEMPERATURE SENSORS SHALL BE INSTALLED AT AN ELEVATION OF 48" ABOVE FINISHED FLOOR TO THE TOP UNLESS OTHERWISE NOTED ON DRAWINGS. LOCATION OF THE WALL MOUNTED THERMOSTAT SHALL BE COORDINATED WITH OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF THERMOSTAT SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER OR HIS REPRESENTATIVE IN THE FIELD. AT THE CONCLUSION OF THE INSTALLATION THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL A COMPLETE CERTIFIED TEST AND BALANCE REPORT FROM AN AGENCY HAVING A MINIMUM OF THREE YEARS EXPERIENCE. REPORT SHALL ITEMIZE THE PERFORMANCE OF EACH AIR DEVICE AND A/C UNIT WITH REGARD TO CFM, STATIC PRESSURE AND TEMPERATURE. MAINTAIN AS-BUILT DRAWINGS, DAILY. SUBMIT TO ARCHITECT/OWNER AFTER COMPLETION OF ALL WORK. SHOP DRAWINGS SHALL BE SUBMITTED TO THE GENERAL CONTRACTOR, ARCHITECT, OWNER & ENGINEER FOR COORDINATION/REVIEW. THESE SHOP DRAWINGS SHALL BE REVIEWED PRIOR TO ORDERING EQUIPMENT AND INSTALLATION.
AutoCAD SHX Text
MARK
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
AIR DEVICE SCHEDULE
AutoCAD SHX Text
AD-1
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
AND MODEL
AutoCAD SHX Text
AD-2
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
RET./EXH.
AutoCAD SHX Text
WHITE
AutoCAD SHX Text
BAKED ENAMEL
AutoCAD SHX Text
WHITE
AutoCAD SHX Text
BAKED ENAMEL
AutoCAD SHX Text
350FL
AutoCAD SHX Text
TITUS
AutoCAD SHX Text
OMNI
AutoCAD SHX Text
TITUS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text PROVIDE 24x24 MODULE WITH ROUND NECK TRANSITION. SEE PLANS FOR NECK SIZES. PROVIDE 24x24 MODULE, WITH 22x22 NECK. PROVIDE WITH R-6 BACKPAN INSULATION. * APPROVED EQUALS SHALL BE GREENHECK, PRICE AND NAILOR.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
CEILING DIFFUSER RUNOUT DETAIL
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CEILING DIFFUSER
AutoCAD SHX Text
DUCT (MAX. 8'-0" LONG)
AutoCAD SHX Text
INSULATED ROUND FLEXIBLE
AutoCAD SHX Text
(EXTERNAL INSULATION)
AutoCAD SHX Text
ROUND METAL DUCT
AutoCAD SHX Text
SUPPLY DUCT
AutoCAD SHX Text
PRODUCTS NO. 654
AutoCAD SHX Text
W/ DAMPER. CROWN
AutoCAD SHX Text
ATTACH INNER LINER WITH PANDUIT
AutoCAD SHX Text
STRAP TO DIFFUSER COLLAR. SEAL
AutoCAD SHX Text
OUTSIDE INSULATION WRAP WITH DUCT
AutoCAD SHX Text
TAPE
AutoCAD SHX Text
RING SEAL COLLAR
AutoCAD SHX Text
NOTE: SUPPORT DIFFUSERS OR GRILLES FROM STRUCTURE, NOT CEILING GRID SYSTEM.
AutoCAD SHX Text
EXISTING DUCTWORK, PIPING, OR EQUIPMENT
AutoCAD SHX Text
TO REMAIN
DAY ROOM
KITCHEN
HALL
103SERVICE
CLOSET
STAIRS
CONSTRUCTION
CHECKED BY
REVIEW
APPROVAL
LA
KE
LA
N
D, F
LO
-1
JO
HN
R . C
UR
TI
S, AI
A
BE
N
JA
M
IN
F . M
UN
DY
, J R.
, A
IA
, L
EE
D
AP
C.
K
EI
TH
H
UN
N
IC
UT
T, A
IA
REVISIONS
N
EI
L G.
M
EL
BY
, A
IA
, L
EE
D
AP
SO
UT
H
FL
O
RI
DA
A
VE
N
UE
3-
8-
TE
LE
PH
O
N E
C M
HM
A
RC
HI
TE
C
TS
IN
C lk lda rc h.
co m
23012
M
IC
H A
E L
C U
R K
A N
P E
PYRAMID
ENGINEERING
04/21/26
03/23/26
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
.4
N B
R
UN
N E L L P
K W
Y L ak e la nd F L
09/15/25
M
EC
HA
N
IC
A L
FL
O
O R
P
LA
N
M201
AutoCAD SHX Text
EXHAUST LUVER
AutoCAD SHX Text
INTAKE LOUVER (EXIST)
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
8" AD-1175 CFM TYP OF 4
AutoCAD SHX Text
8" AD-1225 CFM TYP OF 2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text T
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
AutoCAD SHX Text 10x10
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
(727) 531-2989 * Reg. No. EB6890
AutoCAD SHX Text 5596 Rio Vista Drive
AutoCAD SHX Text Clearwater, Florida 33760
AutoCAD SHX Text C O N S U L T I N G E N G I N E E R S
AutoCAD SHX Text pyramid@pyramidengineering.org
AutoCAD SHX Text
FLOOR PLAN - MECHANICAL
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text /4699-M201
AutoCAD SHX Text MECHANICAL NOTES: : EXISTING SPLIT 'DX' UNIT AHU/CU-1 TO BE REUSED. CLEAN AND SERVICE COMPLETELY PRIOR TO REUSE. REBALANCE UNIT TO: SUPPLY AIR: 1150 CFM 1150 CFM RETURN AIR 175 CFM 175 CFM PROVIDE AND INSTALL NEW TYPE 2 HOOD AND DUCT SYSTEM. EXTEND OUTLET DUCT TO EXISTING EXPANDED WALL OPENING. HOOD SHALL BE A DENLAR MODEL D1036-D-IF-NFPA WITH IN-LINE FAN. BALANCE FAN TO:390 CFM EXPAND EXISTING WALL OPENING TO 16x16 TO ACCOMMODATE NEW WALL LOUVER. LOUVER SHALL BE GREENHECK MODEL EHV-550D (OR APPROVED EQUAL). PROVIDE WITH FULL SIZE, 6" DEEP PLENUM AND INSECT SCREEN. VERIFY COLOR WITH PROJECT ARCHITECT. EXISTING DUCT SYSTEM TO BE REUSED. CLEAN INTERIOR OF DUCT PRIOR TO RESUE AND SEAL ANY OPENINGS AIRTIGHT. PROVIDE AND INSTALL NEW THERMOSTAT IN POSITION INDICATED. THERMOSTAT SHALL BE A HONEYWELL T6 PRO PROGRAMMABLE THERMOSTAT.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVIEW
APPROVAL
LA
KE
LA
N
D, F
LO
-1
JO
HN
R . C
UR
TI
S, AI
A
BE
N
JA
M
IN
F . M
UN
DY
, J R.
, A
IA
, L
EE
D
AP
C.
K
EI
TH
H
UN
N
IC
UT
T, A
IA
REVISIONS
N
EI
L G.
M
EL
BY
, A
IA
, L
EE
D
AP
SO
UT
H
FL
O
RI
DA
A
VE
N
UE
3-
8-
TE
LE
PH
O
N E
C M
HM
A
RC
HI
TE
C
TS
IN
C lk lda rc h.
co m
23012
M
IC
H A
E L
C U
R K
A N
P E
PYRAMID
ENGINEERING
04/21/26
03/23/26
K
IT
C
HE
N R
EN
O
V A
TI
O N
L F D
S
T A T
IO
N N
.4
N B
R
UN
N E L L P
K W
Y L ak e la nd F L
09/15/25
P
LU
M B
IN
G
N O
TE
S, S C
HE
D
UL
ES
A
N D
L
EG
EN
D
P101
AutoCAD SHX Text
(727) 531-2989 * Reg. No. EB6890
AutoCAD SHX Text 5596 Rio Vista Drive
AutoCAD SHX Text Clearwater, Florida 33760
AutoCAD SHX Text C O N S U L T I N G E N G I N E E R S
AutoCAD SHX Text pyramid@pyramidengineering.org
AutoCAD SHX Text
PLUMBING ACCESSORY SCHEDULE
AutoCAD SHX Text
FIXTURE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
APPROVED MANUFACTURERS
AutoCAD SHX Text
STAINLESS STEEL ACCESS COVER
AutoCAD SHX Text
CLEANOUT
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WALL
AutoCAD SHX Text
WALL CLEANOUT:
AutoCAD SHX Text
PVC BODY, GAS AND WATERTIGHT
AutoCAD SHX Text THREAD PLUG, 7"%%c SMOOTH
AutoCAD SHX Text
WITH SECURING SCREW
AutoCAD SHX Text
NO. CO2411-PV4 (BODY)
AutoCAD SHX Text
NO. CO2530-SS7 (COVER)
AutoCAD SHX Text
ZURN-LC
AutoCAD SHX Text
NO. CO44
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
COLD WATER PIPING
AutoCAD SHX Text
HOT WATER PIPING
AutoCAD SHX Text
WALL CLEAN OUT
AutoCAD SHX Text
VENT PIPING
AutoCAD SHX Text
SANITARY PIPING
AutoCAD SHX Text
WCO
AutoCAD SHX Text
PLUMBING LEGEND
AutoCAD SHX Text V
AutoCAD SHX Text
HW
AutoCAD SHX Text
CW
AutoCAD SHX Text
ABBREV.
AutoCAD SHX Text
SS
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
FLOOR SINK
AutoCAD SHX Text
FS
AutoCAD SHX Text
1. CONTRACTOR SHALL PROVIDE COMPLETE PLUMBING SYSTEMS AS DETAILED. CONTRACTOR SHALL PROVIDE COMPLETE PLUMBING SYSTEMS AS DETAILED. WORK CONSISTS OF FURNISHING ALL MATERIALS, EQUIPMENT, AND SERVICES REQUIRED FOR COMPLETE SYSTEMS. 2. CONTRACTOR SHALL COORDINATE ALL PIPING LOCATIONS AND INVERT CONTRACTOR SHALL COORDINATE ALL PIPING LOCATIONS AND INVERT ELEVATIONS WITH FOOTINGS AND FOUNDATIONS BEFORE INSTALLING AND ADJUST AS REQUIRED. 3. ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER PLUMBING DRAWINGS ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER PLUMBING DRAWINGS WITH REFERENCE TO BUILDING CONSTRUCTION. PLUMBING DRAWINGS (PLANS, DIAGRAMS, ETC.) ARE DIAGRAMMATIC AND SHOULD NOT BE SCALED. THE CONTRACTOR SHALL COORDINATE ALL WORK UNDER THIS CONTRACT. 4. IF ANY DISCREPANCIES SHOULD EXIST THE CONTRACTOR SHALL NOTIFY THE IF ANY DISCREPANCIES SHOULD EXIST THE CONTRACTOR SHALL NOTIFY THE ARCHITECT PRIOR TO BIDDING. 5. COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICTS. COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICTS. 6. NECESSARY REQUIRED PLUMBING ITEMS THAT ARE NOT SHOWN ON THE NECESSARY REQUIRED PLUMBING ITEMS THAT ARE NOT SHOWN ON THE DRAWINGS DOES NOT RELIEVE THE CONTRACTOR FROM HIS RESPONSIBILITY TO INSTALL A COMPLETE OPERATING PLUMBING SYSTEM. 7. ALL NEW PLUMBING EQUIPMENT, MATERIALS, AND WORKMANSHIP SHALL BE ALL NEW PLUMBING EQUIPMENT, MATERIALS, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 8. DOMESTIC WATER PIPING SHALL BE: TYPE "K" COPPER BELOW GRADE, WITH DOMESTIC WATER PIPING SHALL BE: TYPE "K" COPPER BELOW GRADE, WITH VINYL SLEEVE FOR ANTI-CORROSION, AND TYPE "L" ABOVE GROUND WITH WROUGHT COPPER FITTINGS (ASTM B16.22-89) AND SOLDER JOINTS. 9. COPPER PIPING INSTALLED WITHIN BLOCK WALLS OR IN CONTACT WITH COPPER PIPING INSTALLED WITHIN BLOCK WALLS OR IN CONTACT WITH CONCRETE SHALL BE INSTALLED WITH 4 MIL POLYETHYLENE PIPE GUARD. BLUE FOR COLD WATER AND RED FOR HOT WATER. 10. UNLESS OTHERWISE NOTED ALL PIPING SHALL BE RUN IN CONCEALED UNLESS OTHERWISE NOTED ALL PIPING SHALL BE RUN IN CONCEALED SPACES. 11. INSULATE ALL HOT WATER, HOT WATER RETURN AND TEMPERED WATER INSULATE ALL HOT WATER, HOT WATER RETURN AND TEMPERED WATER PIPING WITH 1" THICK HIGH DENSITY FIBERGLASS INSULATION WITH, FACTORY APPLIED VAPOR BARRIER ALL SERVICE JACKET. 12. ALL WATER PIPING UNDERGROUND SHALL BE A MINIMUM OF 3 FEET BELOW ALL WATER PIPING UNDERGROUND SHALL BE A MINIMUM OF 3 FEET BELOW GRADE UNLESS OTHERWISE NOTED. 13. FINAL WATER PIPING ROUTING SHALL BE COORDINATED WITH THE GENERAL FINAL WATER PIPING ROUTING SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR. 14. ALL SOIL, WASTE, AND VENT PIPING SHALL BE SCHEDULE 40 PVC. ALL SOIL, WASTE, AND VENT PIPING SHALL BE SCHEDULE 40 PVC. 15. ALL HORIZONTAL SOIL AND WASTE PIPING 2 1/2" IN DIAMETER AND LESS ALL HORIZONTAL SOIL AND WASTE PIPING 2 1/2" IN DIAMETER AND LESS SHALL HAVE A MINIMUM SLOPE OF 1/4" PER ONE FOOT LENGTH OF PIPE. ALL PIPING 3" IN DIAMETER AND LARGER SHALL HAVE A MINIMUM SLOPE OF 1/8" PER ONE FOOT LENGTH OF PIPE. 16. CHROME PLATED ESCUTCHEONS AND NIPPLES ARE REQUIRED AT ALL FLOOR CHROME PLATED ESCUTCHEONS AND NIPPLES ARE REQUIRED AT ALL FLOOR AND WALL PENETRATIONS. 17. PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES SHALL BE SEALED IN AN PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES SHALL BE SEALED IN AN APPROVED MANNER WHICH MAINTAINS THE REQUIRED FIRE RATING OF THE ASSEMBLY. A. WHERE HOLES ARE CIRCULAR, THE PENETRATION SHALL BE PROTECTED WITH FIRE-SEAL SMOKE AND FIRE STOP FITTINGS MANUFACTURED BY O.Z. GEDNEY, LINK SEAL BY THUNDER LINE OR APPROVED EQUAL. B. WHERE HOLES ARE RECTANGULAR, THE PENETRATION SHALL BE PROTECTED WITH DOW CORNING 3-6548, SILICONE RTV FOAM, 3M FIRE BARRIER PENETRATION SEAL SYSTEM, OR APPROVED EQUAL. 18. ALL FIXTURES AND EQUIPMENT SHALL HAVE SHUT-OFF VALVES AT OR ALL FIXTURES AND EQUIPMENT SHALL HAVE SHUT-OFF VALVES AT OR NEAR EQUIPMENT. 19. GATE VALVES SHALL BE #125 BRONZE WITH UNION BONNET. GATE VALVES SHALL BE #125 BRONZE WITH UNION BONNET. 20. PROVIDE AND INSTALL HAMMER ARRESTORS AT FIXTURE GROUPS. INSTALL PROVIDE AND INSTALL HAMMER ARRESTORS AT FIXTURE GROUPS. INSTALL AIR CHAMBERS AT INDIVIDUAL FIXTURES. 21. PROVIDE TRAP PRIMERS AS INDICATED ON DRAWINGS AND WHERE REQUIRED PROVIDE TRAP PRIMERS AS INDICATED ON DRAWINGS AND WHERE REQUIRED BY CODE. 22. MAINTAIN AS-BUILT DRAWINGS, DAILY. SUBMIT TO ARCHITECT/OWNER MAINTAIN AS-BUILT DRAWINGS, DAILY. SUBMIT TO ARCHITECT/OWNER AFTER COMPLETION OF ALL WORK. 23. ALL WORK SHALL COMPLY WITH ALL LOCAL AND STATE CODES, INCLUDING ALL WORK SHALL COMPLY WITH ALL LOCAL AND STATE CODES, INCLUDING THE FLORIDA BUILDING CODE 2023, 8TH EDITION. 24. TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE MINIMUM BUILDING CODES. 25. INSULATE FIRST 20' OF SANITARY PIPING AND P-TRAP WHICH RECEIVE INSULATE FIRST 20' OF SANITARY PIPING AND P-TRAP WHICH RECEIVE WASTE FROM ICE MACHINES. INSULATE WITH ARMAFLEX INSULATION.
AutoCAD SHX Text
%%UPLUMBING GENERAL NOTES:
AutoCAD SHX Text
SIZE 100
AutoCAD SHX Text
APPROVED EQUALS SHALL BE J.R. SMITH & WADE.
AutoCAD SHX Text
HAMMER ARRESTOR SCHEDULE
AutoCAD SHX Text
* CLASSIFICATIONS ESTABLISHED BY THE PLUMBING AND DRAINAGE INSTITUTE "STANDARD P.D.I.-WH201"
AutoCAD SHX Text
ZURN SHOKTROL Z-1700 SERIES
AutoCAD SHX Text
FIXTURE-UNIT RATING
AutoCAD SHX Text
P.D.I. SYMBOLS*
AutoCAD SHX Text 1-11
AutoCAD SHX Text A
AutoCAD SHX Text
SIZE 500
AutoCAD SHX Text 114-154
AutoCAD SHX Text 33-60
AutoCAD SHX Text
SIZE 300
AutoCAD SHX Text 12-32
AutoCAD SHX Text B
AutoCAD SHX Text
SIZE 200
AutoCAD SHX Text 61-113
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
SIZE 400
AutoCAD SHX Text E
AutoCAD SHX Text 155-330
AutoCAD SHX Text F
AutoCAD SHX Text
SIZE 600
AutoCAD SHX Text
FS
AutoCAD SHX Text
NO. FD2370-PV3-H-Y
AutoCAD SHX Text
ZURN-LC
AutoCAD SHX Text
NO. FS56-3-PVC-2G-B
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
FLOOR SINK
AutoCAD SHX Text FLOOR SINK: PVC BODY, 12x12x6 DEEP, COMPLETE WITH SEDIMENT BUCKET, DEEP SEAL TRAP; CONTRACTOR TO COORDINATE HALF GRATE WITH DRAIN FROM EQUIPMENT FURNISHED
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
BACKFLOW PREVENTER SCHEDULE
AutoCAD SHX Text
SERVES
AutoCAD SHX Text
ASSE LISTING
AutoCAD SHX Text
ICE MAKER FILTER
AutoCAD SHX Text
AutoCAD SHX Text
WILKINS
AutoCAD SHX Text
375XL-AG
AutoCAD SHX Text
*APPROVED EQUALS SHALL BE WATTS AND APOLLO
AutoCAD SHX Text
TEE UP
AutoCAD SHX Text
TEE DOWN
AutoCAD SHX Text 90%%d UP
AutoCAD SHX Text 90%%d DOWN
AutoCAD SHX Text
FIXTURE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
INLET
AutoCAD SHX Text
OUTLET
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
GREASE INTERCEPTOR
AutoCAD SHX Text
SCHIER NO. GB-50GB-50
AutoCAD SHX Text GREASE INTERCEPTOR: SEAMLESS, MOLDED POLYETHYLENE WITH MINIMUM 3/8" UNIFORM WALL THICKNESS. INTERCEPTOR SHALL BE FURNISHED FOR ABOVE OR BELOW-GRADE INSTALLATION WITH ADJUSTABLE COVER ADAPTER, SAFETY STAR ACCESS RESTRICTOR ACCESS RESTRICTOR BUILT INTO EACH COVER ADAPTER, AND THREE OUTLET OPTIONS. THIS UNIT IS CERTIFIED FOR HYDROMECHANICAL PERFORMANCE TO ASME A112.14.3 (TYPE D) AND CSA B481.1. INTERCEPTOR FLOW RATE SHALL BE 50 GPM OR 75 GPM. INTERCEPTOR GREASE CAPACITY SHALL BE 439 LBS. PROVIDE WITH GREASE SAMPLING POINT
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text
GREASE INTERCEPTOR
AutoCAD SHX Text
GI
AutoCAD SHX Text
*APPROVED EQUALS SHALL BE WATTS AND APOLLO
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL SERIES
AutoCAD SHX Text
MIXING VALVE SCHEDULE
AutoCAD SHX Text
SERVES
AutoCAD SHX Text
ASSE LISTING
AutoCAD SHX Text
TEMP. SETTING
AutoCAD SHX Text
KITCHEN SINK (LOCATE BELOW SINK WITH ACCESS PANEL)
AutoCAD SHX Text 120°F
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
LFMMV
AutoCAD SHX Text
AutoCAD SHX Text
*APPROVED EQUALS SHALL BE ZURN, SYMMONS AND BRADLEY
AutoCAD SHX Text 104°F
AutoCAD SHX Text
ZURN
AutoCAD SHX Text
ZW1070XL
AutoCAD SHX Text
AutoCAD SHX Text
NEW CONNECTION
AutoCAD SHX Text
1. MOUNTING HEIGHT AS SCHEDULED OR DETAILED. MOUNTING HEIGHT AS SCHEDULED OR DETAILED. 2. TRAPS, SUPPLIES AND ALL OTHER EXPOSED PIPING SHALL BE CAST BRASS TRAPS, SUPPLIES AND ALL OTHER EXPOSED PIPING SHALL BE CAST BRASS WITH A POLISHED CHROME FINISH. ACCEPTABLE MANUFACTURERS INCLUDE McGUIRE OR APPROVED EQUAL. 3. ELECTRIC WATER COOLERS SHALL BE INSTALLED WITH FLOOR MOUNTED ELECTRIC WATER COOLERS SHALL BE INSTALLED WITH FLOOR MOUNTED CARRIERS AT ALL LOCATIONS. 4. ALL FIXTURES SHALL BE SUBMITTED TO OWNER AND ARCHITECT FOR REVIEW ALL FIXTURES SHALL BE SUBMITTED TO OWNER AND ARCHITECT FOR REVIEW AND APPROVAL BEFORE PURCHASING. 5. ALL INDIRECT DRAINS (ID) THAT EXCEED 4'-0" IN TOTAL DEVELOPED LENGTH ALL INDIRECT DRAINS (ID) THAT EXCEED 4'-0" IN TOTAL DEVELOPED LENGTH SHALL BE TRAPPED. ALL INDIRECT WASTE PIPING SHALL DISCHARGE WITH AIR GAP. 6. COORDINATE INSTALLATION OF COUNTER MOUNTED SINKS WITH GENERAL COORDINATE INSTALLATION OF COUNTER MOUNTED SINKS WITH GENERAL CONTRACTOR. DO NOT CUT CABINET SUPPORT ELEMENTS WITHOUT APPROVAL OF THE ARCHITECT. 7. PLUMBING CONTRACTOR SHALL USE ONE MANUFACTURER FOR EACH FIXTURE PLUMBING CONTRACTOR SHALL USE ONE MANUFACTURER FOR EACH FIXTURE TYPE. 8. COLD WATER SUPPLY TO ELECTRIC WATER COOLERS SHALL NOT BE INSTALLED COLD WATER SUPPLY TO ELECTRIC WATER COOLERS SHALL NOT BE INSTALLED NOT BE INSTALLED BE INSTALLED ABOVE RECESSED ELECTRICAL UTILITY BOX.
AutoCAD SHX Text
PLUMBING FIXTURE NOTES:
AutoCAD SHX Text *MANUFACTURER AND MODEL NUMBERS ARE SHOWN AS BASIS OF DESIGN. ANY OTHER ALTERNATES SUBMITTED SHALL BE SIMILAR IN QUALITY AND DESIGN AND WILL BE SUBJECT TO APPROVAL BY THE ARCHITECT AND ENGINEER.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
HOT
AutoCAD SHX Text
COLD
AutoCAD SHX Text
VENT
AutoCAD SHX Text
TRAP
AutoCAD SHX Text
FIXTURE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
APPROVED MANUFACTURERS
AutoCAD SHX Text
PLUMBING FIXTURE AND PIPE SIZING SCHEDULE
AutoCAD SHX Text
AS SHOWN ON PLANS
AutoCAD SHX Text P-1
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text SINGLE COMPARTMENT SINK: LUSTERTONE CLASSIC STAINLESS CLASSIC STAINLESS STEEL, 30-1/2" X 18-1/2" X 7-1/2" SINGLE BOWL UNDERMOUNT SINK WITH PERFECT DRAIN, 18 18 GAUGE 304 STAINLESS STEEL WITH A LUSTROUS SATIN FINISH, REAR CENTER DRAIN PLACEMENT, AND SIDES AND BOTTOM PADS
AutoCAD SHX Text TRIM: SINK FAUCET, 8" SWIVEL SPOUT W/AERATOR, METAL LEVER HANDLE, INSTALL STAINLESS STEEL DRAIN WITH REMOVABLE CRUMB CUP STRAINER. PROVIDE STOPS, SUPPLIES, TRAP, ETC. TO MAKE A COMPLETE INSTALLATION.
AutoCAD SHX Text
DELTA NO. 100LF-HDF100LF-HDF
AutoCAD SHX Text
T&S BRASS NO. B-2731B-2731
AutoCAD SHX Text
SINGLE COMPARTMENT SINK, UNDERMOUNT
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
DISPOSER: PROVIDE WASTE DISPOSER, 120 VOLT, 1/2 HP MOTOR, AND S.S. GRIND CHAMBER
AutoCAD SHX Text
IN-SINK ERATOR NO. 79883, BADGER #579883, BADGER #5
AutoCAD SHX Text P-5
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DISHWASHER: PROVIDED BY OWNER, INSTALLED BY CONTRACTOR
AutoCAD SHX Text
AutoCAD SHX Text
D…