22 - Atch E - Drawing - PHASE 1 - 100 Percent WAPA-FP.pdf

PDF 3 MB Posted

Attached to
DSW Fire Suppression System Upgrade
Solicitation number
89503121BWA000030
Issued by

About this file

This document contains details for a federal contract solicitation and related opportunity. The solicitation is for a competitive 100% Small Business Set-aside Invitation for Bid to upgrade an existing fire suppression system at a Department of Energy facility in Phoenix, Arizona, with an estimated value between $250,000 and $500,000. The scope of work includes removing and replacing all sprinkler heads, furnishing and installing an intelligent, microprocessor controlled, analog addressable fire alarm system, and an option to provide an engineered high-pressure Carbon Dioxide fire suppression system. Responses are due under Solicitation Number 89503121BWA000030. The North American Industry Classification code is 238220 and the size standard is $16.5 million. A firm-fixed price contract will be awarded.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PH

O

EN

IX

O

M C

EN

TE

R

PH

AS

E

I F

IR

E

SP

RI

NK

LE

R

SY

ST

EM

S

UP

GR

AD

E

S.

3r d

A

VE

. P H

O

EN

IX

, A

R

IZ

O N

A W es te rn A re a

Po w er A dm in is tr at io n

D

IS

PA

TC

H A

N D

O

PE

R A

TI

O

N S

B

LD

G

PHOENIX O & M CENTER

PHASE I FIRE SPRINKLER SYSTEMS UPGRADE

615 S. 43rd AVE. PHOENIX, ARIZONAWestern Area Power Administration

DISPATCH AND OPERATIONS BLDG

PROJECT SCOPE

CONTRACT REQUIREMENTS

DEFINITIONS

CONFERENCE

CONFERENCE

CONFERENCE

CONFERENCE

PRINTER

MAINTENANCE

ELECTRICAL

SUPPRESSION

STORAGE

UPS

BATTERY

OFFICE

1124OFFICE

LOBBY

2100OFFICE

OFFICE

OFFICE

OFFICE

1122A

OFFICE

OFFICE

COMMUNICATIONS

SCADA

CARRIER

SHOP

DISPATCH

1108A

OFFICE

1114A

OFFICE

1103 OFFICE

1104 1104A RADIO

SHOP

VEHICLE

1117A

TELEPHONE

STORAGE

WOMEN

MEN

COFFEE

1114B

JANITOR

1112ELECTRICAL

CORRIDOR

CORRIDOR

CORRIDOR

UNIT

SUBSTATION

MATCH LINE FP2.1

MATCH LINE FP2.2

MATCH LINE FP2.1

MATCH LINE FP2.4

FP2.2 - MAIN LEVEL

FP2.1

FP2.3 - LEVEL BELOW

FP2.4

FP2.5 - MAIN LEVEL

FP2.5 - LEVEL ABOVE

SITE KEY/ SHEET INDEX

C

A-B

E

D

Junction box

TBA & TBB

Release Control Panel

Release Solenoid Disconnect Switch

Air Compressor Isolating Switch

Air Compressor (behind Control Panel)

Riser Check Valve

Straight through Deluge Valve

Water Supply Control Valve

Riser Outlet to Sprinklers Network

Cable Entry

Drain Outlet (either side)

Water Inlet (either side)

Test Valve

PH

AS

E I F

IR

E

SP

RI

NK

LE

R

SY

ST

EM

S

UP

GR

AD

E

LOBBY

2100OFFICE

OFFICE

OFFICE

CORRIDOR

OFFICE

2108B

OFFICE

2108A

OFFICE

2107 OFFICE

JANITOR

ELEC

2112WOMEN'S

MECHANICAL

OFFICE

OFFICE

CORRIDOR

OFFICE

OFFICE

OFFICE

ELEC

MEN'S

IDF

MECHANICAL

CORRIDOR

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

2130C

OFFICE

OFFICE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

OFFICE

2130B

OFFICE

2130A

CONFERENCE ROOM

MATCH LINE FP2.1

MATCH LINE FP2.2

M A

T C

H L

IN

E

F P

2.

M A

T C

H L

IN

E

F P

2.

FP2.2 - MAIN LEVEL

FP2.1

FP2.3 - LEVEL BELOW

FP2.4

FP2.5 - MAIN LEVEL

FP2.5 - LEVEL ABOVE

SITE KEY/ SHEET INDEX

C

A-B

E

D

PH

AS

E I F

IR

E

SP

RI

NK

LE

R

SY

ST

EM

S

UP

GR

DRAWING

STORAGE

REPRODUCTION

OFFICE

CAD

OFFICE

CORRIDOR

OFFICE

CONFERENCE

ROOM

LIBRARY

OFFICE

OFFICE

OFFICE

CLOSET

2018A

OFFICE

OFFICE

OFFICE

2022A

OFFICE

CONFERENCE

OFFICE

CORRIDOR

STORAGE

OFFICE

OFFICE

OFFICE

COFFEE

MEN

ELEC

CORRIDOR

IDF

WOMEN

LOBBY

OFFICE

OFFICE

OFFICE

2004C

OFFICE

2004BOFFICE

2004A

OFFICE

OFFICE

OFFICE

2005A

OFFICE

JAN

M A

T C

H L

IN

E

F P

2.

M A

T C

H L

IN

E

F P

2.

FP2.2 - MAIN LEVEL

FP2.1

FP2.3 - LEVEL BELOW

FP2.4

FP2.5 - MAIN LEVEL

FP2.5 - LEVEL ABOVE

SITE KEY/ SHEET INDEX

C

A-B

E

D

PH

AS

E I F

IR

E

SP

RI

NK

LE

R

SY

ST

EM

S

UP

GR

MECHANICAL

LUNCH

CORRIDOR

CORRIDOR

OFFICE

OFFICE

EXERCISE

OFFICE

OFFICE

CORRIDOR

WOMENS

RESTROOM

2156 MENS

RESTROOM

LOCKERS

SHOWER ROOM

CORRIDOR

OFFICE

2151 2150B

2150D

LINE

CREW

OFFICE

2150A

CORRIDOR

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

IDF

WOMEN

MEN

JANITOR

CORRIDOR

OFFICE

OFFICE

AGAVE

CONFERENCE ROOM

2160A

LOCKERS

SHOWER ROOM

MATCH LINE FP2.1

MATCH LINE FP2.4

M A

T C

H L

IN

E

F P

2.

M A

T C

H L

IN

E

F P

2.

M A

T C

H L

IN

E

F P

2.

M A

T C

H L

IN

E

F P

2.

OFFICE

OFFICE

LUNCH

OFFICE

1118A

OFFICE

OFFICE

1118B

DISPATCH

VIDEO/

AUDIO

SMOKE

1111A

MEN

WOMEN

CORRIDOR

1120A

RTU

LAB

1105A

VEHICLE

STORAGE

DRAWING

STORAGE

REPRODUCTION

OFFICE

CAD

OFFICE

CORRIDOR

OFFICE

CONFERENCE

ROOM

LIBRARY

OFFICE

OFFICE

OFFICE

CLOSET

2018A

OFFICE

OFFICE

OFFICE

FP2.2 - MAIN LEVEL

FP2.1

FP2.3 - LEVEL BELOW

FP2.4

FP2.5 - MAIN LEVEL

FP2.5 - LEVEL ABOVE

SITE KEY/ SHEET INDEX

C

A-B

E

D

PH

AS

E I F

IR

E

SP

RI

NK

LE

R

SY

ST

EM

S

UP

GR

LINE

CREW

CORRIDOR

YARD

STORAGE

OFFICE

2169B 2169C 2169D

I.T.

OFFICE

STORAGE

VEHICLE

BAYS

2169AOFFICE

OFFICE

OFFICE

CORRIDOR

OFFICE

OFFICE

ELEC

SHOP

CENTRAL FILES &

MAILROOM

REST

ROOM

UPPER

BAYS

UPPER

PART

MEZZ/ MECH

ELECTRICAL

UPPER

PART OF

UPPER

PART OF

UPPER

PART OF

UPPER

PART OF

MEZZ/ MECH

ELECTRICAL

CONFERENCE

ROOM

CENTRAL FILES

ARCHIVES

M A

T C

H L

IN

E

F P

2.

M A

T C

H L

IN

E

F P

2.

FP2.2 - MAIN LEVEL

FP2.1

FP2.3 - LEVEL BELOW

FP2.4

FP2.5 - MAIN LEVEL

FP2.5 - LEVEL ABOVE

SITE KEY/ SHEET INDEX

C

A-B

E

D

PH

AS

E I F

IR

E

SP

RI

NK

LE

R

SY

ST

EM

S

UP

GR

Sheets and Views
PHASE 1 - 100% WAPA-FP-COV.
PHASE 1 - 100% WAPA-FP-FP1.0
PHASE 1 - 100% WAPA-FP-FP1.1
PHASE 1 - 100% WAPA-FP-FP1.2
PHASE 1 - 100% WAPA-FP-FP1.3
PHASE 1 - 100% WAPA-FP-FP1.4
PHASE 1 - 100% WAPA-FP-Spec. Cover

File details come from the government source that posted it. Updated .