22-12_Attachment C_Drawings.pdf
PDF 2 MB Posted
- Attached to
- 22-12 Tech Tower Elevator Modernization
- Solicitation number
- BD-22-1064-1064-02481-73393
- Issued by
- Norfolk County, Massachusetts
About this file
This document contains attachments and drawings for a state and local contract opportunity for the Tech Tower Elevator Modernization project for the Massachusetts Bay Community College in Wellesley, Massachusetts. The project scope includes the modernization of the elevators in the Tech Tower building, including new elevator cabs, control systems, and supporting mechanical, electrical, and fire alarm work. The project drawings and specifications provide detailed requirements for the elevator work, as well as supporting building systems. The project is being bid as a 100% bid set, with a due date to be determined. The contract term is not specified, but it is presumed to be for the duration of the elevator modernization project.
The pricing terms and funding sources are not detailed in this document. There are no indications of any set-asides or incumbent contractors. The overall project appears to be funded by the Commonwealth of Massachusetts and Massachusetts Bay Community College. Additional salient information, such as bonding requirements, prevailing wage compliance, or small business participation, is not included in this set of attachments.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Commonwealth_StandardContract2019.pdf | ||
| Commonwealth_TermsConditions2019.pdf | ||
| eft-form.pdf | ||
| 22-12 BID TAB.xlsx | XLSX spreadsheet | |
| 22-12_Attachment B_Specifications.pdf | ||
| Vendor_W9.pdf | ||
| 22-12_Attachment A_Prevailing Wage.pdf | ||
| 22-12_IFB_TechTowerElevatorModernization~1.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G0-00 COVER SHEET
G0-01 ABBREVIATIONS, SYMBOLS & MOUNTING HEIGHTS
A1-00 ATTIC & 5TH FLOOR ROOF PLAN
A1-01 TYPICAL ELEVATOR PLAN & ELEVATIONS
A1-02 ELEVATOR MACHINE ROOM PLANS & ELEVATIONS
A2-01 MACHINE ROOM STAIR DETAILS
A2-02 DOOR & HARDWARE SCHEDULE, MISC. DETAILS
H0-01 LEGEND AND SPECIFICATIONS
H0-02 MECHANICAL SCHEDULES, DETAILS & SEQUENCE OF CONTROLS
H1-01 MECHANICAL PLANS
E0-01 ELECTRICAL LEGEND AND SPECIFICATIONS
E0-02 ELECTRICAL DETAILS
E1-01 ELECTRICAL PLANS
FA0-01 FIRE ALARM LEGEND AND SPECIFIFCATIONS
FA1-01 FIRE ALARM PLANS
SHEET LIST
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
ARCHITECT: MEP ENGINEER:
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
BLW ENGINEERS INC.
G0-00 11/29/2021
100% BID SET
MASSBAY COMMUNITY COLLEGE TECH TOWER 1919 ELEVATOR MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
THE COMMONWEALTH OF MASSACHUSETTS
MASSACHUSETTS BAY COMMUNITY COLLEGE
WELLESLY HILLS, MASSACHUSETTS
LOCUS PLAN
1/32" = 1'-0"1 PROJECT SCOPE PLAN
KEYNOTE
BUILDING ELEVATION
INTERIOR ELEVATIONS
BUILDING SECTION
WALL SECTION CALLOUT
DETAIL CALLOUT
DOOR TAG
SPOT ELEVATION
WALL/PARTITION TAG
WINDOW TAG
ROOM TAG
LEVEL IDENTIFICATION
VIEW TITLE
STRUCT. GRID REFERENCE
A0.00
00 VIEW TITLE
SCALE: 1/2" = 1'-0"
0.00
A0.00
A0.00
101A
A0.00
NAME
ELEVATION
A0.00
PLAN DETAIL CALLOUT
A0.00
A
ROOM NAME
ROOM NO.
FLR FINISH
AREA
A
MATERIAL/FINISH TAG
BREAK LINE
CL CENTERLINE
REVISION CLOUD
FLOOR
ROOM #
A-Z FOR NUMBER OF
DOORS IN A ROOM
EARTH
GRANULAR FILL
BRICK OR C.S.M.U.
CONCRETE
CONCRETE MASONRY UNITS
GYPSUM WALL BOARD OR GROUT
NOM. LUMBER
FINISH WOOD
PLYWOOD
RIGID INSULATION
BATT INSULATION & MINERAL WOOL
STEEL
STONE (CUT OR CAST)
EPOXY RESIN
SPRAY FOAM INSULATION
SOLID SURFACE
BLOCKING/SHIM
AVB MEMBRANE
WATER PROOFING
FLASHING
ALUMINUM
ACCESSIBLE FIXTURES & ACCESSORIES
FEMININE NAPKIN DISPOSAL
(WOMENS TOILET ROOM STALLS, TYP.)
TOILET TISSUE DISPENSER
STANDARD TOILET STALL FIXTURES & ACCESSORIES
CL
" A
FF
CL
CL
RECESSED TOILET TISSUE
DISPENSER
1-1/2" DIA. GRAB BAR, 1-1/2"
FROM WALL
ACCESSIBLE TOILET STALL FIXTURES & ACCESSORIES
32"
CL
CL
" M
AX
FO
RW
AR
D R
EA
CH
FIRE ANNUNCIATOR
ANNUNCIATOR, THERMOSTAT, INTERCOM & CLOCK
CL
CL CL
EXIT SIGNCUSTODIAL CLOSET
SERVICE SINK W/ VINYL
RIMGUARD
" M
IN.
AF
F.
" M
AX
CL
PAPER TOWEL DISPENSER
SOAP DISPENSER
TO
CO
NT
RO
LS
" M
IN.
" M
AX
CL
CL
34"
" M
IN.
CL
" M
AX
12" MIN.24" MIN.
CL
FLUSH CONTROL (ON
WIDE SIDE OF TOILET
AREA)
18"
" M
AX
" M
AX
" 30
PHONE JACK, ELEC. OUTLET, SWITCH, FIRE ALARM HORN
& PULL STATION
" M
IN.TELEPHONE/ DATA
CONNECTION
ELEC. OUTLET
LIGHT SWITCH
PULL STATION
FIRE ALARM
AUDIO/ VISUAL DEVICE
SID
E R
EA
CH
THERMOSTAT
INTERCOM
CLOCK
ALIGN W/ DOOR
HEAD
EQ EQ
3"
4"
3"
EXIT EXIT
TACTILE EXIT SIGN
CEILING MOUNT RECESSED OR WALL
MOUNTED
NOTE: PROVIDE TACTILE EXIT SIGNAGE WHERE ILLUMINATED EXIT SIGNS ARE REQUIRED OR
WHERE REQUIRED BY CBC 1011.3
EQ EQ
CL
EXIT
4"
6" -8
EXIT
FLOOR LEVEL EXIT SIGN
BACKSPLASH, TYP.
5, 3'-0"x10" x3/4" ADJT. SHELVES ON 3 RECESSED
METAL STANDARDS. PROVIDE BLOCKING BEHIND
STANDARDS.
8"
36" MIN.
PROVIDE TWO DUPLEX OUTLETS, MIN.
" M
IN.
36" MAX.
12" MAX.
42" MIN.
54" MIN.
36" GRAB BAR
" 54
SE
E E
LE
C D
WG
S
18"
C.L. OF SINK TO WALL, MIN.
1-1/2" DIA. GRAB BAR,
1-1/2" FROM WALL
LA
TC
H S
IDE
ROOM SIGNAGE
WALL MTD. SIGNAGE
CL
3"
ACCESSIBLE DRINKING FOUNTAIN/BOTTLE FILLER
MI
N.27
" MA
X.
12" MAX
PROVIDE EQUIPMENT SHOWN
SEE SCHEDULES FOR FIXTURES AND ACCESSORES MAKE/MODEL SEE SCHEDULES FOR FIXTURES AND ACCESSORES MAKE/MODEL
OF BRAIL
SEE SCHEDULES FOR FIXTURES AND ACCESSORES MAKE/MODEL
ACCESSIBLE SHOWER STALL
FOLDING SEAT
30" X 60" STALL
CL
CL
SINGLE LEVER
CONTROL
FLEX HAND SPRAYER UNIT
CL27" MAX.
FLOOR SLOPE 2%
MAX.
RECESSED SOAP DISH
TO
TO
P O F M
NT
BR
AC
KE
T
27"
MAX.
19" MIN.
SEE SCHEDULES FOR FIXTURES AND ACCESSORES MAKE/MODEL
CENTERLINE
DEMOLISHED
HIDDEN
OVERHEAD/BEYOND
GRID LINE
PROPERTY LINE / PROJECT SCOPE
MATCH LINE
SUPPLY DIFFUSER
EXHAUST DIFFUSER
RECESSED LIGHT FIXTURE
SURFACE MOUNTED LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE
DUPLEX
DUPLEX WITH GROUND FAULT
QUADPLEX
QUADPLEX WITH GROUND FAULT
TEL/DATA OUTLET
LINEAR DIFFUSER
PROJ SCR PROJECTION SCREEN
PROP PROPOSED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT(ED)
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER & RECEPTOR
PTN PARTITION
PTR PAPER TOWEL RECEPTOR
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PWD PLYWOOD
QT QUARRY TILE
QTY QUANTITY
R RISER
RA RETURN AIR
RAD RADIUS
RB RUBBER BASE
RBH ROBE HOOK
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REINFORCE(D), (ING)
REF REFERENCE
REFR REFRIGERATOR
REM REMOVE
REQD REQUIRED
RES RESILIENT
REV REVISION
RFL REFLECT(ED), (IVE), (OR)
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
RSF RESILIENT SHEET FLOORING
RT RESILIENT TILE
RWL RAINWATER LEADER
S SOUTH
SA SPRAY ACOUSTIC
SB SINK BASE
SC SEALED CONCRETE
SCH SCHEDULE
SD SOAP DISPENSER
SEC SECTION
SH SHELF, SHEVLING
SHT SHEET
SHTH SHEATHING
SHWR SHOWER
SIM SIMILAR
SJT SEISMIC EXPANSION JOINT
SM SHEET METAL
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTOR
SNT SEALANT
SOG SLAB ON GRADE
SPEC SPECIFICATION(s)
SQ SQUARE
SST STAINLESS STEEL
ST STAIR
STA STATION
STC SOUND TAMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STR STRUCTUR(E), (AL)
SUSP SUSPENDED
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TB TOWEL BAR
TC TERRA COTTA
TC TOP OF CONCRETE
TEL TELEPHONE
TEMP TEMPORARY
TF TOP OF FOOTING
THK THICK(NESS)
TJ TOP OF JOIST
TKBD TACKBOARD
TPD TOILET PAPER DISPENSER
TSL TOP OF SLAB
TST TOP OF STEEL
TW TOP OF WALL
TYP TYPICAL
TZ TERRAZZO
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF, V.I.F. VERIFY IN FIELD
VIN VINYL
VP VENEER PLASTER
VPWD VENEER PLYWOOD
VWC VINYL WALL COVERING
W WEST, WIDE, WIDTH
W/ WITH
WC WATER CLOSET
WD WOOD
WH WATER HEATER
WI WROUGHT IRON
WIN WINDOW
WM WIRE MESH
WO WITHOUT
WP WORK POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
ZTC ZINC-TIN COATED
ZTCC ZINC-TIN COATED COPPER
FF FINISHED FLOOR
FFE FURNITURE, FIXTURES & EQUIPMENT
FFO FLUSH FLOOR OUTLET
FHC FIRE HOSE CABINET
FHWS FLATHEAD WOOD SCREW
FIN FINISH(ED)
FIXT FIXTURE
FLG FLASHING
FLR FLOOR(ING)
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FPRF FIREPROOF
FR FIRE RATING, FRAME
FS FULL SIZE
FSS FOLDING SHOWER SEAT
FT FIRE TREATED
FTG FOOTING
FUR FURRED(ING)
GA GAGE, GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GRADE, GRADING
GF GROUND FACE
GL GLASS, GLAZING
GLB GLASS BLOCK
GMU GLASS MASONRY UNIT
GR GRILLE
GT GROUT
GWB GYPSUM WALLBOARD
HB HOSE BIB
HC HOLLOW CORE
HD HAND DRYER
HDB HARDBOARD
HDW HARDWARE
HM HOLLOW METAL
HORZ HORIZONTAL
HP HIGH PERFORMANCE
HPT HIGH PAINT
HR HOUR
HT HEIGHT
HVAC HEATING/VENTILATING/AIR CONDITIONING
ID INSIDE DIAMETER
IDF INTERMEDIATE DISTRIBUTION FACILITY
IN INCH
INCL INCLUDE(D), (ING)
INSUL INSULATE(D), (ION)
INT INTERIOR
INV INVERT
J JOIST
JAN JANITOR
JT JOINT
KIT KITCHEN
LAM LAMINATE(D)
LAV LAVATORY
LCC LEAD-COATED COPPER
LCKR LOCKER
LH LEFT HAND
LNDG LANDING
LPT LOW POINT
LS LIGHT SWITCH
LT LIGHT
LTWT LIGHT WEIGHT
LVR LOUVER
M MIRROR
M.A.S. MASONRY ANCHORING SYSTEM
MACH MACHINE
MAS MASONRY
MAT MATERIAL(S)
MAX MAXIMUM
MBH MOP & BROOM HOLDER
MBRD MACHINE BOARD
MBRD MARKER BOARD
MC MEDICINE CABINET
MECH MECHANICAL
MFR MANUFACTURE(R)
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOLDING, MOULDING
MN MANUAL
MO MASONRY OPENING
MOD MODULAR
MR MOISTURE RESISTANT
MTD MOUNTED
MTL METAL
MWRK MILLWORK
N NORTH
NA NOT APPLICABLE
NC NONCORROSIVE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPS NOMINAL PIPE SIZE
NTS NOT TO SCALE
OA OVERALL
OC, O.C. ON CENTER(S)
OD OUTSIDE DIAMTER
OFOI OWNER FURNISHED, OWNER INSTALLED
OH OVERHEAD
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OTA OPEN TO ABOVE
OTB OPEN TO BELOW
OZ OUNCE
P.L. E.L. PRECAST LINTEL ELEVATION
PBD PARTICLE BOARD
PERF PERFORATE(D)
PFB PREFABRICATE(D)
PL PLASTER
PLAM PLASTIC LAMINATE
PLN PLAN
PM PRESSED METAL
PNL PANEL
PR PAIR
PRL PICTURE RAIL
A/C AIR CONDITIONING
AB ANCHOR BOLT
ABV ABOVE
ACOUS ACOUSTICAL
ACT ACOUSTICAL TILE
ADA AMERICANS W/ DISABILITIES ACT
ADD ADDENDUM
ADH ADHESIVE
ADJ ADJACENT
ADJT ADJUSTABLE
AESS ARCHITECTURALLY EXPOSED STRUCTURAL
STEEL
AF ATHLETIC FLOOR(ING)
AFF ABOVE FINISHED FLOOR
AGG AGGREGATE
AL ALUMINUM
ALRM ALARM
ALT ALTERNATE
AMT AMOUNT
ANC ANCHOR, ANCHORAGE
ANOD ANODIZED
AP ACCESS PANEL, ACOUSTIC PANEL
APPROX APPROXIMATE
ARCH ARCHITECT(URAL)
AUTO AUTOMATIC
AVG AVERAGE
AWP ACOUSTIC WALL PANEL
BBRD BULLETIN BOARD
BD BOARD
BD BODY DRYER
BDF BLDG DISTRIBUTION FACILITY
BEL BELOW
BIT BITUMINOUS
BKT BRACKET
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRG BEARING
BRK BRICK
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
BW BOTTOM OF WALL
CAB CABINET
CB CEMENT BOARD
CBRD CHALK BOARD
CD COMBINATION DISPENSER
CEM CEMENT
CG CORNER GUARD
CI CAST IRON
CJT CONTROL JOINT
CLNG CEILING
CLO CLOSET
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
COMP COMPRESS(ED), (ION), (IBLE)
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUE(D)
CONTR CONTRACTOR
CORR CORRIDOR
CPT CARPET(ED)
CRS COURSE
CSFH COUNTERSUNK FLAT HEAD
CT CERAMIC TILE
CTR CENTER
CTSK COUNTERSINK
CUH CABINET UNIT HEATER
DA DOUBLE ACTING
DBL DOUBLE
DCS DIAPER CHANGING STATION
DEMO DEMOLISH, DEMOLITION
DEPR DEPRESS(ED), (ION)
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIAM DIAMETER
DIM DIMENSION
DISP DISPOSAL
DN DOWN
DO DOOR OPENING
DP DISABLED PERSONS
DPR DISPENSER
DR DOOR
DTL DETAIL
DW DISHWASHER
DWG DRAWING
DWR DRAWER
E EAST
EA EACH
EJT EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EM ENTRY MAT
EMER EMERGENCY
ENC ENCLOSE(URE)
EQ EQUAL
EQP EQUIPMENT
ERA EXTERIOR ROOF ASSEMBLY
ETR EXISTING TO REMAIN
EWA EXTERIOR WALL ASSEMBLY
EWC ELECTRIC WATER COOLER
EXG EXISTING
EXH EXHAUST
EXP EXPANSION, EXPOSED
EXP EXPOSED
EXT EXTERIOR
EXTD EXTRUDED
FA FIRE ALARM, FLOOR ASSEMBLY
FAB FABRICATED
FB FIBER BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS
MATERIAL PATTERNS
STANDARD MOUNTING HEIGHTS
ARCHITECT
MECHANICAL ELECTRICAL
PLUMBING ENGINEERING
STAMP
REVISIONS
NUMBER DATE DESCRIPTION
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
BLW ENGINEERS INC.
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
KEY PLAN
ABBREVIATIONS,
SYMBOLS &
MOUNTING HEIGHTS
03/21/2022
MASSBAY
COMMUNITY COLLEGE
TECH TOWER 1919
ELEVATOR
MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
G0-01
100% BID SET
0 42
NORTHMEP COORDINATION
LINETYPES
ARCHITECT
MECHANICAL ELECTRICAL
PLUMBING ENGINEERING
STAMP
REVISIONS
NUMBER DATE DESCRIPTION
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
BLW ENGINEERS INC.
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
KEY PLAN
ATTIC & 5TH FLOOR
ROOF PLAN
03/21/2022
MASSBAY
COMMUNITY COLLEGE
TECH TOWER 1919
ELEVATOR
MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
A1-00
100% BID SET
1/16" = 1'-0"1 ATTIC LEVEL PLAN
NEW HEAT PUMP, SEE ELECTRICAL &
MECHANICAL DRAWINGS FOR DETAILS
ETR ROOFTOP UNITS
ELEVATOR
MACHINE
ROOM
SHAFT V.I.F.
5'-7 1/2"
2'- 1 1
/2" 3'-
4" 2'-
1 1 /2"
SH
AF
T V .I.F
8'-
6 1 /4"
PL
AT
F O
RM
6'- 3"
CA
B
5'-
SHAFT
5'-7 1/2"
V.I .F.
2'- 1 1
/2" V.I
.F.
3'-
4" V.I
.F.
2'-
1 1 /2"
V.I .F.
8'- 6 1
/4" A1-01 6
A1-01 9
PL
AT
F O
RM
6'- 3"
EL
EV
AT
OR
SH
AF
T 7'-
7"
PLATFORM
4'-11 1/2"
EQEQ
8" 2'-
6" 4"
EQ EQ EQ
V.I .F.
3'- 6"
3'- 2"
4"
EQ EQ
V.I.F.
4'-1 1/2"
A1-01
4" 2'-
6" 8"
V.I.F.
5'-11"
2'- 2"
4"
CL
3'- 6"
3'- 6"
A1-01 6
CA
B
5'-
CAB
4'-1 1/2"
A1-01
EQ
EQ
EQ
EQ EQ
PLAM PLAM
#4 SATIN SS
A1-01
1" 1/8"
1" 1/8
1/8" 1/4" 1/8"
1/4
ARCHITECT
MECHANICAL ELECTRICAL
PLUMBING ENGINEERING
STAMP
REVISIONS
NUMBER DATE DESCRIPTION
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
BLW ENGINEERS INC.
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
KEY PLAN
TYPICAL ELEVATOR
PLAN & ELEVATIONS
03/21/2022
MASSBAY
COMMUNITY COLLEGE
TECH TOWER 1919
ELEVATOR
MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
A1-01
100% BID SET
1/2" = 1'-0"1 EXISTING TYPICAL ELEVATOR FLOOR PLAN
1/2" = 1'-0"2 TYPICAL ELEVATOR FLOOR CONSTRUCTION PLAN
1/2" = 1'-0"5 INTERIOR ELEVATION - ELEVATOR CAB - NORTH
1/2" = 1'-0"6 INTERIOR ELEVATION - ELEVATOR CAB - EAST
1/2" = 1'-0"7 INTERIOR ELEVATION - ELEVATOR CAB - SOUTH
1/2" = 1'-0"8 INTERIOR ELEVATION - ELEVATOR CAB - WEST
1/2" = 1'-0"9 INTERIOR ELEVATION - TYPICAL ELEVATOR ENTRY (APPLY TO ALL 5 FLOORS)
1/2" = 1'-0"3 ELEVATOR CAB PLAN
1/2" = 1'-0"4 ELEVATOR CAB REFLECTED CEILING PLAN
HIGH IMPACT PLASTIC LAMINATE
1/2" STAINLESS STEEL TRIM
BETWEEN PLASTIC LAMINATE
PANELS
#4 SATIN STAINLESS STEEL PANEL
#4 SATIN STAINLESS STEEL BASE
#4 SATIN STAINLESS STEEL BASE
HIGH IMPACT PLASTIC LAMINATE
1" STAINLESS STEEL TRIM AROUND
ELEVATOR DOOR, VERIFY EXACT DOOR
LOCATION WITH EXISTING OPENING
#4 SATIN STAINLESS STEEL PANELS
1/2" STAINLESS STEEL TRIM
BETWEEN PLASTIC LAMINATE &
STAINLESS STEEL PANELS
SATIN STAINLESS STEEL CEILING
LED DOWNLIGHT, TYP.
NEW 12" TILE, FINISH SELECTION
WILL
BE MADE IN THE SUBMITTAL
PROCESS
TILE SETTING OUT POINT
NEW CALL BUTTION W/ LANTERN
TO MATCH EXISTING
EXISTING OPENING
NEW 2" STAINLESS STEEL WRAP
OVER ETR METAL FRAME
#4 SATIN STAINLESS STEEL
ELEVATOR DOOR
ELEVATOR CONTROL PANEL
ACCESS HATCH LOCATION
2"x1/4" SATIN STAINLESS
STEEL HANDRAIL
HIGH IMPACT PLASTIC
LAMINATE
1/2" STAINLESS STEEL TRIM
BETWEEN PLASTIC LAMINATE
PANELS
#4 SATIN STAINLESS
STEEL PANEL
#4 SATIN STAINLESS
STEEL BASE
#4 SATIN STAINLESS STEEL
PANELS
HIGH IMPACT PLASTIC LAMINATE
1/2" STAINLESS STEEL TRIM
BETWEEN PLASTIC LAMINATE
PANELS
#4 SATIN STAINLESS
STEEL PANELS
#4 SATIN STAINLESS STEEL BASE
HANDRAIL MOUNT (3)
CENTERED ON EACH PANEL
3" = 1'-0"10 ELEVATION DETAIL - ELEVATOR PANEL TRIM
3" = 1'-0"11 PLAN DETAIL - ELEVATOR CORNER TRIM
3" = 1'-0"12 PLAN DETAIL - ELEVATOR PANEL TRIM
1/8" STAINLESS
STEEL TRIM
1/8" STAINLESS
STEEL TRIM
2"x1/4" SATIN STAINLESS
STEEL HANDRAIL
1/8" STAINLESS
STEEL TRIM
NEW STAINLESS STEEL CORNER
GUARDS
ALUMINUM PAD BUTTONS,
TYP.
ALUMINUM PAD BUTTONS,
TYP.
ALUMINUM PAD BUTTONS,
TYP.
1/4" REVEAL, PAINTED. PAINT
COLOR SELECTION TO BE MADE IN
SUBMITTAL PROCESS
HANDRAIL MOUNT (2)
CENTERED ON EACH PLAM
PANEL
2"x1/4" SATIN STAINLESS
STEEL HANDRAIL
HANDRAIL MOUNT (2) CENTERED
ON EACH PLAM PANEL
2"x1/4" SATIN STAINLESS
STEEL HANDRAIL
HANDRAIL MOUNT (2)
CENTERED ON EACH PLAM
PANEL ABOVE
2"x1/4" SATIN STAINLESS
STEEL HANDRAIL
HANDRAIL MOUNT (2)
CENTERED ON EACH PLAM
PANEL ABOVE
UP
V.I.F.
8'-0"
V.I .F.
9'-
9"EXISTING
POWER
UNIT TO BE
REMOVED
V.I.F.
8'-0"
V.I .F.
9'- 9"A1-02 4
A1-02
A1-02
7 A1-029
NEW
POWER
UNIT
A2-01
NEW POWER UNIT
NEW POWER UNIT
NEW POWER UNIT
ARCHITECT
MECHANICAL ELECTRICAL
PLUMBING ENGINEERING
STAMP
REVISIONS
NUMBER DATE DESCRIPTION
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
BLW ENGINEERS INC.
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
KEY PLAN
ELEVATOR MACHINE
ROOM PLANS &
ELEVATIONS
03/21/2022
MASSBAY
COMMUNITY COLLEGE
TECH TOWER 1919
ELEVATOR
MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
A1-02
100% BID SET
1/2" = 1'-0"1 ELEVATOR MACHINE ROOM DEMOLITION PLAN
1/2" = 1'-0"2 ELEVATOR MACHINE ROOM CONSTRUCTION PLAN
1/2" = 1'-0"3 INTERIOR ELEVATION - ELEVATOR MACHINE ROOM - NORTH
1/2" = 1'-0"4 INTERIOR ELEVATION - ELEVATOR MACHINE ROOM - EAST
1/2" = 1'-0"5 INTERIOR ELEVATION - ELEVATOR MACHINE ROOM - SOUTH
1/2" = 1'-0"7 INTERIOR ELEVATION - OUTSIDE ELEVATOR MACHINE ROOM - WEST
1/2" = 1'-0"8 INTERIOR ELEVATION - OUTSIDE ELEVATOR MACHINE ROOM - SOUTH
1/2" = 1'-0"9 INTERIOR ELEVATION - OUTSIDE ELEVATOR MACHINE ROOM - EAST
DEMO 12"x12" (1sf)
FLOOR GRILLE
ETR 24"x24" LOUVER
EXTENT OF ELEVATOR
SHAFT BELOW
EXISTING OIL LINE
NEW 12"x36" (3sf)
FLOOR GRILLE
1/2" = 1'-0"6 INTERIOR ELEVATION - ELEVATOR MACHINE ROOM - WEST
ETR 24"X24" LOUVER
EXTENT OF ELEVATOR
SHAFT BELOW
ETR OIL LINE
DEMO STAIRS
DEMO DOOR
ETR 24"x24" LOUVER
ETR UNDERSIDE OF ROOF
NEW 1 1/2-HR RATED
DOOR IN EXISTING
MASONRY OPENING,
VERIFY EXISTING
OPENING IN FIELD
NEW OPEN METAL
GRATE STAIR
DEMO STAIR, LANDING
& RAILINGS
ETR 24"X24" LOUVER
NEW OPEN METAL
GRATE STAIR, REFER
TO A2-01 FOR DETAILS
NEW OPEN METAL
GRATE STAIR, REFER
TO A2-01 FOR DETAILS
A2-01
A2-01
A2-01
ELEVATOR MACHINE ROOM
1 1 /2"
2'- 2"
2'- 2"
2 1 /2"
A2-02
A2-02
6R @ 11"EA
5'-6" 3'-8 3/8" 3"
3/4" 2'-9" 2'-9"
4' -8
A2-01
C12X20.7 STRINGER
HS
S 4
X4 X1
/4
1'- 6"
1'- 6"
3'-
2'-2" 2'-2"
A2-01
A2-01
A2-01
7-
RIS
ER
V.I
.F.
1'-
6" 1'-
6"
2'-9"2'-9"1'-11 3/8"1'-11 3/8"
C12X20.7 STRINGER
HS
S 4
X4 X1
/4
1'-0"
9'-4 3/4"
A2-01
A2-01
4" 1/4" 1'-2" 1/4" 4 3/4" 1/8"
1'-1 1/2" 1/4"
6"
4"
1'-0"
1'- 6"
1'- 6"
7-
RIS
ER
S
" V
.I.F
A2-022'-9"2'-9"
2 1 /2"
4" 1/2
2"
2"
6"
6"
ARCHITECT
MECHANICAL ELECTRICAL
PLUMBING ENGINEERING
STAMP
REVISIONS
NUMBER DATE DESCRIPTION
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
BLW ENGINEERS INC.
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
KEY PLAN
MACHINE ROOM
STAIR DETAILS
03/21/2022
MASSBAY
COMMUNITY COLLEGE
TECH TOWER 1919
ELEVATOR
MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
A2-01
100% BID SET
1" = 1'-0"1 ENLARGED PLAN - MACHINE ROOM STAIR
1" = 1'-0"3 CROSS SECTION - ELEVATOR MACHINE ROOM STAIR - EAST
1" = 1'-0"2 CROSS SECTION - ELEVATOR MACHINE ROOM STAIR - SOUTH
GALVINIZED HANDRAIL @ 18"
& 36", 1 1/2" DIA.
SCHEDULE 40 STEEL TUBE
C12X20.7 STRINGER
HSS4X4X1/4 CORNER POST,
WELDED TO C12 STRINGERS
HSS4"x4"x1/4" CORNER
POST, WELDED TO C12
STRINGERS
C12X20.7 STRINGER
1" = 1'-0"4 CROSS SECTION - ELEVATOR MACHINE ROOM STAIR - NORTH
2"x3/16"x1 1/2"D GALVI
GRATING STAIR TREAD W/
CHECKER PLATED GALVI NOSING
GALVINIZED STEEL BALUSTER,
WELD TO C12 STRINGER
GALVINIZED HANDRAIL @ 18"
& 36", 1 1/2" DIA.
SCHEDULE 40 STEEL TUBE
GALVINIZED HANDRAIL @ 18"
& 36", 1 1/2" DIA.
SCHEDULE 40 STEEL TUBE
2X2 GALVI STEEL ANGLE TREAD
SUPPORT SHOP WELDED TO
STRINGER
2"x2"x1/4" GALVI STEEL ANGLE SHOP WELDED TO STRINGER W/ 1/2"x 4 1/2"
EPOXY INJECTED GALVI ANCHOR BOLTS
INTO EXISTING CONCRETE SLAB
CONTINUOUS 2X2 GALVI STL SUPPORT
ANGLE, SHOP WELD ANGLES ONTO
STRINGER PRIOR TO DELIVERING ON SITE
CONTINUOUS 2"x2"x1/4" GALVI STL
SUPPORT ANGLE, SHOP WELD ANGLES
ONTO STRINGER PRIOR TO DELIVERING
ON SITE
2X2 GALVI STEEL ANGLE TREAD
SUPPORT SHOP WELDED TO TO
STRINGER
2"x 3/16" x1 1/2" GALVI
GRATING STAIR TREAD W/
CHECKER PLATED GALVI NOSING
HSS4X4X1/4 CORNER POST,
WELDED TO C12 STRINGERS
3" = 1'-0"5 METAL GRATE WALKWAY - ANCHOR DETAIL
2"X1/4" GALVI GRATING
2"x2"x1/4" GALVI STL SUPPORT ANGLE, SHOP WELD ANGLES ONTO STRINGER
PRIOR TO DELIVERING ON SITE
GALVI STL GRATING CLIP FASTENED TO
STL SUPPORT ANGLE
STL GRATE CLIP FASTENER
3" = 1'-0"6 TYPICAL METAL GRATE STAIR TREAD
2X2 GALVI STEEL ANGLE TREAD
SUPPORT SHOP WELDED TO
STRINGER
2"L x 3/16"W x 1 1/2"D GALVI
GRATING STAIR TREAD W/
CHECKER PLATED GALVI NOSING
GALVI STL GRATING CLIP
FASTENED TO STL
SUPPORT ANGLE
STL GRATE CLIP FASTENER
C12X20.7 STRINGER
3" = 1'-0"7 STAIR CONNECTION DETAIL
2"x3/16"x1 1/2"D GALVI
GRATING
2"L x 3/16"W x 1 1/2"D GALVI
GRATING
ETR STEEL CHANNEL, VERIFY
EXACT SIZE OF CHANNEL IN
FIELD PRIOR TO FABRICATING
STEEL ATTACHMENTS
2X2 GALVI STL SUPPORT ANGLE, SHOP
WELD ANGLES ONTO STRINGER PRIOR TO
DELIVERING ON SITE
CHECKER PLATED GALVI
STEEL NOSING
2"L x 3/16"W x 1 1/2"D GALVI
GRATING
C9X20 INTERMEDIATE
STEEL CHANNEL SUPPORT
L6"x6"x1/4" THICK STEEL ANGLE SHOP
WELDED TO C12 STRINGER PRIOR TO
BEING DELIVERED ON SITE ON ONE SIDE.
OTHER SIDE BOLTED TO ETR STEEL
CHANNEL
FASTEN STEEL PLATE TO EXISTING STEEL
CHANNEL. DRILL HOLES INTO EXISTING
CHANNEL
1/2"Dx4 1/2"L GALVI ANCHOR
BOLT EPOXY INJECTED INTO
ETR CONCRETE SLAB
2X2 GALVI STL SUPPORT ANGLE
BOLTED TO ETR STEEL CHANNEL
2"x3/16"x1 1/2"D GALVI
GRATING STAIR TREAD W/
CHECKER PLATED GALVI NOSING
4"x2"x1/4" GALVI STL SUPPORT ANGLE, SHOP WELD ANGLES ONTO STRINGER
PRIOR TO DELIVERING ON SITE
C9X20 INTERMEDIATE STEEL CHANNEL
SUPPORT
C9X20 STEEL CHANNEL
SUPPORTS
4"x2"x1/4" GALVI STL SUPPORT
ANGLE, SHOP WELD ANGLES ONTO
STRINGER PRIOR TO DELIVERING
ON SITE
1/2"Dx4 1/2"L GALVI ANCHOR
BOLT FASTENED TO ETR STEEL
CHANNEL
6"x6"x1/4" GALVI STEEL PLATE W/ 1/2"x 4 1/2" EPOXY INJECTED GALVI ANCHOR
BOLTS INTO EXISTING CONCRETE SLAB
2"x2"x1/4" GALVI STEEL ANGLE SHOP WELDED TO STRINGER W/ 1/2"x 4 1/2"
EPOXY INJECTED GALVI ANCHOR BOLTS
INTO EXISTING CONCRETE SLAB
ITEM DESCRIPTION / FUNCTION HARDWARE SET
BUTTS AND HINGES / PIVOT SET01
DOOR STOP: FLOOR OR WALL AS NEEDED
CLOSER (ANSI A156.4)
KICK PROTECTION PLATE (34" WIDE X 8" HIGH, BOTH SIDES OF DOOR)
DOOR HARDWARE SCHEDULE
KICK-DOWN HOLD OPEN
LOCATIONS:
NEW
DOOR
NOTE: SEE SPEC SECTION 087100 DOOR HARDWARE
ALL FINISHES SHALL BE US32D SATIN STAINLESS STEEL UNLESS NOTED OTHERWISE
PERIMETER FIRE + SMOKE SEAL (NFPA 80 + 285, UL10B, UL10C)
MORTISE LOCKSET (ANSI A156.13, F07 STOREROOM)
DOOR SWEEP (UL10B, UL10C)
HMF = HOLLOW METAL FRAME
DOOR + HW NOMENCLATURE
SSFP = STEEL SHEET, FACTORY PRIME, FIELD PAINT
SF = SINGLE FLUSH
SIC = STEEL INSULATED CORE
6 1/8" 1 3/4" 2 5/8" 1 3/4"
1/4"
A2-02
1 3/4" 3'-0" 2"
V.I.F.
3'-4" MASONRY OPENING
ARCHITECT
MECHANICAL ELECTRICAL
PLUMBING ENGINEERING
STAMP
REVISIONS
NUMBER DATE DESCRIPTION
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
BLW ENGINEERS INC.
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
KEY PLAN
DOOR & HARDWARE
SCHEDULE, MISC.
DETAILS
03/21/2022
MASSBAY
COMMUNITY COLLEGE
TECH TOWER 1919
ELEVATOR
MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
A2-02
100% BID SET
DOOR SCHEDULE
Ty pe
M ar k
W idt h
He igh t
Fr am e T yp e
Ha rd wa re
Fir e R at ing
Comments
1 3'-0" 7'-0" HMF 1 1 1/2-HR SF, SIC, SSFP
3" = 1'-0"1 SECTION DETAIL - ELEVATOR MACHINE ROOM DOOR
3" = 1'-0"2 PLAN DETAIL - ELEVATOR MACHINE ROOM DOOR
ETR 6" CMU
NEW MASONRY ANCHORS
NEW HOLLOW METAL FRAME
NEW HOLLOW METAL FRAME
CONCRETE BEAM OVER
MASONRY OPENING
SEALANT W/ BACKER ROD
SINGLE FLUSH, STEEL
INSULATED CORE, 1 1/2 HR-
RATED
SINGLE FLUSH, STEEL
INSULATED CORE, 1 1/2 HR-
RATED
NEW MASONRY ANCHORS
ETR CONCRETE SLAB
ETR STEEL CHANNEL
THRESHOLD, FASTENED INTO
ETR CONCRETE SLAB
*VERIFY EXISTING OPENING IN FIELD PRIOR TO ORDERING NEW DOOR
1. MECHANICAL WORK INDICATED (PIPING, DUCT, ETC.) IS DIAGRAMMATIC. EXACT LOCATIONS OF ALL COMPONENTS ARE TO BE DETERMINED IN THE FIELD (SPACING SUBJECT TO ARCHITECT'S REVIEW AND APPROVAL) TO AVOID CONFLICT WITH OTHER TRADES
AND EXISTING SITE CONDITIONS.
2. THE CONTRACTOR SHALL VISIT AND CAREFULLY EXAMINE THE SITE TO IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT THE WORK OF THIS SECTION. REPORT IN WRITING (THROUGH THE GENERAL CONTRACTOR) TO THE OWNER AND ARCHITECT ANY CONDITIONS WHICH MIGHT ADVERSELY AFFECT WORK. NO EXTRA PAYMENT WILL BE PROVIDED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY AN EXPERIENCED OBSERVER.
3. WORK REQUIRING INTERRUPTION OF BUILDING SERVICES SHALL BE CAREFULLY REVIEWED AND COORDINATED WITH THE OWNER TO
MINIMIZE FREQUENCY AND DURATION OF SERVICE INTERRUPTIONS.
4. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF CEILING GRID, DIFFUSERS, AND GRILLES.
5. ALL INSTALLATIONS SHALL PERMIT AND PROVIDE ACCESSIBILITY FOR SERVICE AND REPLACEMENT OF ALL NEW EQUIPMENT AND
EXISTING EQUIPMENT IMPACTED BY THIS WORK.
6. COORDINATE ALL OPENINGS IN FLOORS WITH STRUCTURAL DRAWINGS AND GENERAL CONTRACTOR.
7. COORDINATE ALL ROOF OPENINGS WITH ARCHITECT AND STRUCTURAL ENGINEER.
8. REFER TO STRUCTURAL FRAMING PLANS FOR EXACT LOCATION OF ALL ROOF MOUNTED EQUIPMENT.
9. ALL MECHANICAL EQUIPMENT, PIPING, AND DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF GOVERNING LOCAL, STATE, AND FEDERAL SEISMIC CODES. PARTICULAR ATTENTION SHALL BE MADE TO VIBRATION ISOLATION, ANCHORING, AND BALANCING REQUIREMENTS.
10. ALL DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH CODES AND STANDARDS SET FORTH IN NFPA, SMACNA, AND ASHRAE
FOR MEDIUM AND LOW PRESSURE DUCTWORK SYSTEMS.
11. ALL EXPOSED DUCTWORK SHALL BE PAINTED TO MATCH CEILING. REFER TO ARCHITECTURAL DRAWINGS.
12. PROVIDE MANUAL VOLUME DAMPERS AT ALL BRANCH DUCTS FOR AIR BALANCING. ALL VOLUME DAMPERS LOCATED ABOVE INACCESSIBLE CEILING OR BEHIND INACCESSIBLE WALL SHALL BE PROVIDED WITH REMOTE WIRE DAMPER AT THE AIR OUTLETS.
13. ALL SHEET METAL PLENUMS AT OUTSIDE AIR LOUVERS SHALL BE INSULATED WITH RIGID INSULATION, AS PER SPECIFICATION.
14. RUN-OUTS TO RETURN AND EXHAUST REGISTERS, OR GRILLES ABOVE GYP BOARD CEILINGS, SHALL BE RIGID DUCTED. NO FLEXIBLE
DUCT WORK SHALL BE ALLOWED ON RETURN OR EXHAUST REGISTERS.
15. ALL DUCTS, PIPES, AND EQUIPMENT SHALL BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE WITH PROPER
ALLOWANCES FOR CONTRACTION, EXPANSION, AND VIBRATION ELIMINATION.
16. PROVIDE COPPER 1" RUN-OUTS TO HOT WATER REHEAT COILS, CABINET HEATERS AND UNIT HEATERS UNLESS NOTED OTHERWISE.
17. PROVIDE SWING JOINTS AT ALL BRANCH CONNECTIONS TO HYDRONIC EQUIPMENT.
18. ROOM THERMOSTATS SHALL BE MOUNTED 4'-0" ABOVE FINISHED FLOOR UNLESS OTHERWISE SHOWN OR DIRECTED.
19. COORDINATE EXACT LOCATION OF UNIT HEATERS WITHIN ELECTRIC ROOMS WITH ELECTRICAL CONTRACTOR.
20. REFER TO SPECIFICATIONS FOR TYPE OF VALVE TO BE USED. VALVES ARE SHOWN ON PLANS FOR PLACEMENT ONLY.
21. ALL DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR FREE AREA REQUIRED.
22. ALL DIFFUSER, REGISTER, AND GRILLE SIZES INDICATED ON FLOOR PLANS ARE NECK SIZE REQUIRED.
23. ALL PIPING IS TO BE SLOPED A MINIMUM OF 1/4" PER HUNDRED FEET IN THE DIRECTION OF DRAINAGE.
24. NOT ALL SYMBOLS OR ABBREVIATIONS ARE USED ON THIS PROJECT.
25. COORDINATE ENTIRE INSTALLATION WITH THE WORK OF ALL OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATIONS.
26. OBTAIN ALL REQUIRED PERMITS AND PAY ALL FEES RELATED TO SAME.
27. REVIEW ALL ARCHITECTURAL, STRUCTURAL, PLUMBING, ELECTRICAL, FIRE PROTECTION AND SITE DRAWINGS BEFORE STARTING ANY WORK TO BECOME FAMILIAR WITH THE DETAILS OF CONSTRUCTION, AND COORDINATE WITH OTHER TRADES.
28. PROVIDE ALL NECESSARY PIPING, EQUIPMENT AND SUPPORTS AS WELL AS ANY ADDITIONAL EQUIPMENT, ETC. NOT SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS BUT NECESSARY TO PROVIDE COMPLETE AND WORKABLE SYSTEMS.
29. PROVIDE ACCESS TO ALL EQUIPMENT REQUIRING PERIODIC SERVICE AND MAINTENANCE.
30. DO NOT SCALE THESE DRAWINGS. TAKE ALL MEASUREMENTS IN THE FIELD IN COORDINATION WITH ALL EQUIPMENT AS APPROVED
AND WITH ALL OTHER TRADES.
31. FOR EQUIPMENT SCHEDULES, SEE DRAWING H0.2
32. ALL DUCTWORK SHALL BE INSTALLED ON ACCORDANCE WITH THE LATEST EDITION OF SMACNA
33. ALL HOT WATER, REFRIGERANT AND CONDENSATE PIPING SHALL BE INSULATED IN ACCORDANCE WITH THE MASSACHUSETTS STATE
BUILDING CODE.
34. ALL PIPING HIGH POINTS SHALL HAVE 3/4 INCH VENTS AND LOW POINTS SHALL HAVE 3/4" DRAINS.
35. ALL ROTATING EQUIPMENT SHALL HAVE FLEXIBLE PIPE ON DUCT CONNECTIONS AND APPROVED VIBRATION ISOLATORS.
36. DETAILS SHOWN ON SHEET H0.3 AND H0.4 ARE APPLICABLE TO ALL EQUIPMENT, EXCEPT WHERE INDICATED.
37. PROVIDE AIRTIGHT ACCESS DOOR FOR INSPECTION OF FIRE DAMPERS, FILTERS, AND COILS.
38. CONTRACTOR SHALL VERIFY DUCT, PIPING AND EQUIPMENT LOCATIONS FOR INTERFERENCES BEFORE INSTALLATION.
39. PROVIDE VERTICAL SUPPORTS FOR HOT WATER, REFRIGERANT AND CONDENSATE PIPING AT THE FOLLOWING MAXIMUM INTERVALS;
15' FOR 6"& 5" DIAMETER PIPE; 12' FOR 4" DIAMETER PIPE; 10' FOR 3" & 2-1/2" DIAMETER PIPE; 8' FOR 2" DIAMETER PIPE; 7' FOR 1-1/2 &
1-1/4" DIAMETER PIPE; 5' FOR 1" & 3/4" DIAMETER PIPE.
40. REFERENCE DRAWING H0.5 & H0.6 FOR SEQUENCE OF OPERATION OF NEW EQUIPMENT.
41. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS.
GENERAL NOTES
DEMOLITION NOTES
1. PRIOR TO COMMENCING WORK OF THIS SECTION, EXAMINE SITE AND CONDITIONS UNDER WHICH WORK WILL BE PERFORMED.
DETERMINE EXACT LOCATIONS OF EXISTING EQUIPMENT, PIPING AND CONTROLS. REPORT TO OWNER ANY CONDITIONS THAT MIGHT ADVERSELY AFFECT WORK. COMMENCEMENT OF WORK SHALL BE CONSTRUED AS COMPLETE ACCEPTANCE OF EXISTING CONDITIONS
AND PREPARATORY WORK.
2. ABANDONING OF DUCTWORK, PIPING OR EQUIPMENT IN PLACE SHALL NOT BE ALLOWED. COMPLETE REMOVAL REQUIRED UNLESS NOTED
OTHERWISE.
3. DUCTS TO BE REMOVED: REMOVE PORTION OF DUCTS INDICATED TO BE REMOVED & CAP REMAINING DUCTS WITH SAME OR
COMPATIBLE DUCTWORK MATERIAL.
4. EQUIPMENT TO BE REMOVED: DISCONNECT AND CAP SERVICES AND REMOVE EQUIPMENT.
5. EQUIPMENT TO BE SALVAGED: DISCONNECT, CAP SERVICES, REMOVE EQUIPMENT, DELIVER TO OWNER.
6. COMPLY WITH ALL STATE & LOCAL CODES AS TO REMOVAL & DISPOSAL OF EQUIPMENT FROM SITE.
7. COMPLY WITH GOVERNING EPA NOTIFICATION REGULATIONS BEFORE BEGINNING SELECTIVE DEMOLITION.
8. REMOVE PREVIOUSLY ABANDONED WORK IN THE WAY OF EXISTING CONSTRUCTION, OR AS NOTED.
9. COMPLY WITH HAULING AND DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
10. PERMITS: GIVE ALL REQUIRED NOTICES, FILE ALL REQUIRED PLANS AND SPECIFICATIONS RELATING TO THE WORK OF THIS SECTION
WITH THE PROPER AUTHORITIES AND PAY FOR ANY REQUIRED PERMITS.
11. ALL AIR-CONDITIONING EQUIPMENT AND SYSTEMS SHALL BE REMOVED OR DEMOLISHED WITHOUT RELEASING REFRIGERANTS.
REFRIGERANT RECOVERY IS TO BE PERFORMED BY A REFRIGERANT RECOVERY TECHNICAL CERTIFIED BY AN EPA-APPROVED
CERTIFICATION PROGRAM.
12. ALL EQUIPMENT AND SYSTEMS TO BE REMOVED OR DEMOLISHED UNDER THIS SECTION AND NOT DESIRED BY OWNER SHALL BECOME THE PROPERTY OF THE CONTRACTOR. THE CONTRACTOR SHALL REMOVE ALL SUCH EQUIPMENT FROM THE SITE PROMPTLY AFTER
DETACHMENT FROM BUILDING STRUCTURE.
13. EXISTING PIPING SHOWN ON DRAWINGS DOES NOT INDICATE FULL EXTENT OF PIPING DEMOLITION. FIELD VERIFICATIONS REQUIRED.
REVISION CLOUD
CAP EXISTING
CONNECT TO EXISTING
DRAWING REVISION NOTE
NEW WORK NOTE
EQUIPMENT DESIGNATIONACCU-1
DRAWING NOTES
LIMIT OF DEMOLITION
QUANTITY
NECK SIZE OR LENGTH IF LINEAR DIFFUSER
AIR VOLUME (CFM)
SUPPLY/RETURN/EXHAUST REGISTER OR GRILLE
QUANTITY
NECK SIZE OR LENGTH IF LINEAR DIFFUSER
AIR VOLUME (CFM)
SUPPLY DIFFUSER DESIGNATION
DEMOLITION SCOPE
DEMOLITION WORK NOTE
CONTROL SCHEMATIC LEGEND
DUCT SMOKE DETECTOR
TEMPERATURE SENSOR
HUMIDITY SENSOR
TIME CLOCK CONTROLLER
SWITCH CONTROLLER
HEAT/COOL THERMOSTAT
CONTROL LINE
REVERSE ACTING THERMOSTAT
FILTER GAUGE
VARIABLE FREQUENCY DRIVE
AIR FLOW MEASURING STATION
ENTHALPY CONTROL
FLOW RATE SENSOR
DIFFERENTIAL PRESSURE SENSOR
FREEZESTAT
CAPILLARY TUBE
CO SENSOR
CO2 SENSOR
FLOW SWITCH
HIGH LIMIT THERMOSTAT
STATIC PRESSURE SENSOR
NORMALLY OPEN CONTACT
NORMALLY CLOSED CONTACT
COIL
DIFFERENTIAL PRESSURE SENSOR
PIPING LEGEND
VV
STUB UP TO TERMINAL
PIPE DOWN
PIPE UP
BRANCH CONNECTION
RUN-OUT OFF BOTTOM
RUN-OUT OFF TOP
PIPE OFF TOP
PIPE OFF BOTTOM
DIRECTION OF FLOW
PIPING TO BE REMOVED
EXISTING PIPING TO REMAIN
PIPE BREAK
PC PUMPED CONDENSATE
VENT
LPS LOW PRESSURE STEAMLPS
LPC LPC LOW PRESSURE STEAM CONDENSATE
HWS HWS HOT WATER SUPPLY
MUW MAKE UP WATER
D CD A.C. CONDENSATE DRAIN
RHG RHG REFRIGERANT HOT GAS
RL RL REFRIGERANT LIQUID
RS RS REFRIGERANT SUCTION
CWR CWR CONDENSER WATER RETURN
CWS CWS CONDENSER WATER SUPPLY
CHR CHR CHILLED WATER RETURN
CHS CHS CHILLED WATER SUPPLY
HWR HWR HOT WATER RETURN
DRAIN PIPE PITCH AND FLOW
(DIRECTION TO BE FIELD DETERMINED)
GV GATE VALVE
GLV GLOBE VALVE
BLV BALL VALVE
BFV BUTTERFLY VALVE
DV DRAIN VALVE
SCV SWING CHECK VALVE
LCV LIFT CHECK VALVE
BALANCE COCKBC
BV BALANCE VALVE
PRV PRESSURE REDUCING VALVE
TWO WAY AUTOMATIC CONTROL VALVEACV
ACV THREE WAY AUTOMATIC CONTROL VALVE
SC SELF CONTAINED CONTROL VALVE
UNION
FLG FLANGE
PLS PIPE LINE STRAINER
BASKET STRAINERBKS
CONCENTRIC REDUCER (ENLARGER)CRD
ECCENTRIC REDUCER (ENLARGER)ERD
PRESSURE GAUGEPG
FLOW SWITCHFSW
AUTOMATIC AIR VENTAAV
MANUAL AIR VENTMAV
FLOW MEASURE STATIONFMS
PIPE ANCHORAN
PIPE GUIDEGD
EXPANSION COMPENSATOREC
PIPE FLEXIBLE CONNECTIONPFC
RV RELIEF VALVE
TRM THERMOMETER
VALVE LEGEND
PRESSURE/TEMPERATURE PLUGPT
PIPE CAP
STRAINER WITH DRAIN VALVE AND CAP
IS ISOLATION VALVE REFER TO DETAILS AND SPEC.
MANUAL AIR VENT
MULTI-PURPOSE VALVE
FD FIRE DAMPER
S
M
SMOKE DAMPER
MOTORIZED OR AUTOMATIC CONTROL DAMPER
BACK DRAFT DAMPER
VOLUME DAMPER
DAMPER LEGEND
ACD
SD
BD
VD
FD
BD
FS FIRE & SMOKE DAMPERFS
ZONE DAMPERZD
RADIATION DAMPERRD
VB VACUUM BREAKER
UNIT VENTILATORUV
UH UNIT HEATER (WATER OR STEAM)
VI VIBRATION ISOLATION
PUMPP
LOUVERLU
HEAT EXCHANGERHX
H HUMIDIFIER
FIN TUBE RADIATIONFTR
FCU FAN COIL UNIT
EB ELECTRIC BASEBOARD
BOILER
AIR HANDLING UNITAHU
B
CONVECTORCV
CUH CABINET UNIT HEATER
AIR FLOW STATION
AIR COOLED CONDENSING UNITACCU
AFS
EQUIPMENT TAGS
AIR CONDITIONING UNITAC
CP CONDENSATE PUMP
EXHAUST GRILLEEG
RG RETURN GRILLE
SD SUPPLY DIFFUSER
SR SUPPLY REGISTER
EXHAUST REGISTERER
RR RETURN REGISTER
SG SUPPLY GRILLE
EXHAUST FANEF
SF SUPPLY FAN
RF RETURN FAN
EDH ELECTRIC DUCT HEATER
AIR SEPARATORAS
EXPANSION TANKET
ELECTRIC UNIT HEATEREUH
TRANSFER AIR GRILLETG
TOILET EXHAUST FANTF
HOT WATER PUMPHWP
KITCHEN EXHAUST FANKF
HEAT PUMPHP
HYDRAULIC SEPARATORHS
COMBUSTION AIRCA
CAP CAPACITY
BRITISH THERMAL UNIT PER HOUR
BRITISH THERMAL UNIT
BOTTOM OF DUCTBOD
BTUH
BTU
C CLOSED
AUTOMATIC TEMPERATURE CONTROLATC
AP
ARCH.
AFF
AD ACCESS DOOR
ABOVE FINISHED FLOOR
ACCESS PANEL
ARCHITECT
AAV AUTOMATIC AIR VENT
VARIABLE FREQUENCY DRIVEVFD
WB WET BULB TEMPERATURE (°F)
TA
TD
SST SATURATED SUCTION TEMPERATURE
TRANSFER AIR
TRANSFER AIR DUCT
UC UNDERCUT DOOR
ETBR
ETR
EXISTING TO BE REMOVED
EXISTING TO REMAIN
FINS PER INCHFPI
FULL LOAD AMPSFLA
FA
EXH
EX. EXISTING
EXHAUST
FREE AREA
GALLONS PER MINUTE
GENERAL EXHAUST
GENERAL CONTRACTORGC
GE
GPM
HP HORSE POWER
KILOWATTSKW
ID
KF
IN
HVAC HEATING, VENTILATION AND AIR CONDITIONING
INCHES
INSIDE DIAMETER
KITCHEN EXHAUST FAN
MECHANICALMECH
LD
MBH
LWT
LAT LEAVING AIR TEMPERATURE
LEAVING WATER TEMPERATURE
LOUVERED DOOR
THOUSANDS OF BRITISH THERMAL UNITS PER HOUR
FEET
COMBINATION FIRE AND SMOKE DAMPER
FEET PER MINUTEFPM
FT
FSD
GAL GALLONS
POUNDS PER SQUARE INCH
PRESSURE DROP
PSI
PD
RA RETURN AIR
RM ROOM
PLUMBING CONTRACTOR
OUTSIDE DIAMETER
OPPOSED BLADE DAMPEROBD
OD
PC
NC NORMALLY CLOSED
OUTSIDE AIR TEMPERATUREOAT
NTS
OAI
NO
NIC NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR INTAKE
STATIC PRESSURE
STAND ALONE DIGITAL CONTROLLERSDC
SP
SPD SPEED
SS STAINLESS STEEL
SUPPLY AIRSA
SAT SUPPLY AIR TEMPERATURE
EACHEA.
DRAWINGDWG
ENERGY MANAGEMENT SYSTEMEMS
ENTERING AIR TEMPERATURE
EXHAUST AIREA
EAT
DIGITAL OUTPUTDO
DIA.
DN
DDC
DB DRY BULB TEMPERATURE (°F)
DIRECT DIGITAL CONTROL
DIAMETER
DOWN
CONTROL VALVE
CURRENT TRANSFORMERCT
CV
CONTR CONTRACTOR
CONNECTCONN.
ABBREVIATIONS
DRAINDR
FLOOR DRAINFLD
ELECTRICAL CONTRACTOREC
EXTERNAL STATIC PRESSUREESP
ENTERING WATER TEMPERATUREEWT
HEATING COILHC
SQUARE FEETSF
WMS WIRE MESH SCREEN
EL EXPANSION LOOP
THERMOSTAT
TYPICALTYP
TSTAT
OA OUTSIDE AIR
EXHAUST FANEF
OPEN END DUCTOED
TF TOILET EXHAUST FAN
CLEAN OUT
CUBIC FEET PER MINUTECFM
CO
CAS
CAR COMBUSTION AIR RELIEF
COMBUSTION AIR SUPPLY
COOLING COILCC
CONDENSATE DRAINCD
ABBREVIATIONS
ARCHITECT
MECHANICAL ELECTRICAL
PLUMBING ENGINEERING
STAMP
REVISIONS
NUMBER DATE DESCRIPTION
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
BLW ENGINEERS INC.
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
KEY PLAN
3/21/2022
MASSBAY
COMMUNITY COLLEGE
TECH TOWER 1919
ELEVATOR
MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
100% BID SET
MECHANICAL
LEGEND
H0-01
AutoCAD SHX Text 10"%%C, 12"x12" SG-A, RG-A or EG-A
AutoCAD SHX Text
200 CFM
AutoCAD SHX Text
(TYP. OF 3)
AutoCAD SHX Text 12"x12", SD
AutoCAD SHX Text
200 CFM
AutoCAD SHX Text
(TYP. OF 3)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TS
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text
DSD
AutoCAD SHX Text E1
AutoCAD SHX Text F
AutoCAD SHX Text
DPS
AutoCAD SHX Text
VFD
AutoCAD SHX Text
%%UAFS-
AutoCAD SHX Text
FZ
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO2
AutoCAD SHX Text
FS1
AutoCAD SHX Text
HLT
AutoCAD SHX Text
SP1
AutoCAD SHX Text
DPS
AutoCAD SHX Text
AV
TAG NO.
MANUFACTURER
(AS STANDARD)
MODEL NO.
(AS STANDARD) TYPE
WALL MOUNTED
FAN DATA
MAX ESP
(CFM) (IN.WC.)
FANS
MIN
(CFM)
ELECTRICAL DATA
PHASE HZ
MCA
(A)
VOLTS
MOCP
(A)
REMARKS
NOTES:
1) PROVIDE WIRED THERMOSTAT MOUNTED TO WALL.
FCU-1 MITSUBISHI PKA-A30KA7 775 570 - - 208 1 60 1 -
SPLIT DX FAN COIL UNIT SCHEDULE
PROVIDE UNIT WITH DISCONNECT SWITCH, CONDENSATE PUMP (LITTLE GIANT MODEL VCC-20ULS or
SIMILAR), CONDENSATE OVERFLOW SENSOR, THERMOSTAT AND ALL CONTROLS
OA
(CFM)
MOTOR
(W)
COOLING HTG-NOM
(MBH) (MBH)
DX COIL DATA
HTG-AUX
(KW)
EER
30 34 21 - 9.5
HTG-17°F
(MBH)
TAG NO.
MANUFACTURER
(AS STANDARD)
MODEL NO.
(AS STANDARD) TYPE
SINGLE ZONE
COOLING HTG-NOM
(MBH) (MBH)
CAPACITY DATA
REFRIG. EER
FAN DATA
ESP
(IN.WC.)
FANS
MAX
(CFM)
ELECTRICAL DATA
PHASE HZ
MCA
(A)
VOLTS
MOCP
(A)
REMARKS
NOTES:
1) UNIT SHALL BE CAPABLE OF INDICATED HEATING CAPACITY AT 17°F AND OF OPERATION IN HEATING MODE WITH AMBIENT TEMPERATURES AT OR BELOW 17°F.
HP-1 MITSUBISHI PUZ-A30NHA7 30 34 21 R-410A 9.5 1940 xx xx 208 1 60 19 26
AIR SOURCE HEAT PUMP UNIT SCHEDULE
PROVIDE WITH BREAKER, DISCONNECT SWITCH, LOW AMBIENT OPERATION, EQUIPMENT PAD AND/OR 24"
(MIN) EQUIPMENT STAND AS REQUIRED.
MOTOR
(FLA)
HTG-17°F
(MBH)
xx
WEIGHT
(LBS)
153-
MOD
(NO.)
LOCATION
SERVED
ELEV. MACH. RM
LOCATION
SERVED
ELEV. MACH. RM
TAG NO.
MANUFACTURER
(AS STANDARD)
MODEL NO.
(AS STANDARD) FINISH REMARKS
TR TITUS 33RL
REGISTER, GRILLE & DIFFUSER SCHEDULE
SYSTEM
SERVED
NOTES:
1) COORDINATE FINISH & COLOR WITH ARCHITECT.
2) PROVIDE FRAME SUITABLE FOR SURFACE MOUNTING ON FLOOR.
3) REFER TO DRAWINGS FOR CFM UNLESS NOTED ABOVE.
4) PROVIDE OPPOSED BLADE DAMPER.
[1][2][3][4]TBD
DAMPER
NO
MATERIAL
ST
MAX
NC LEVEL
MAX
VELOCITY
(FPM)
~500
CFM RANGE
FRAME
TYPE
RECTANG.
MOUNTING
FLOOR
NECK
SIZE
--ELEV. SHAFT
HVAC SCHEDULES
HVAC DETAILS
HVAC SEQUENCE OF CONTROLS
THE INDIVIDUAL FAN COIL UNITS SHALL BE CONTROLLED THROUGH THE CORRESPONDING SPACE THERMOSTAT AND THE MASTER CONTROL UNIT. THE SEQUENCE LISTED BELOW IS REVERSIBLE UNLESS NOTED OTHERWISE.
THE SYSTEM SHALL BE IN HEATING MODE WHEN THE OUTDOOR AIR TEMP IS BELOW 60° (ADJ.) THE SYSTEM SHALL BE IN
COOLING MODE WHEN THE OUTDOOR AIR TEMPERATURE IS ABOVE 70° (ADJ.)
THE HEAT PUMP UNIT SHALL ENERGIZE AND OPERATE PER THE MANUFACTURE'S SEQUENCES. THE FAN COIL UNIT
SUPPLY FAN SHALL ENERGIZE TO LOW SPEED AND OPERATE CONTINUOUSLY.
DURING HEATING MODE. UPON A CALL FOR HEAT FROM THE SPACE THERMOSTAT, THE FAN COIL UNIT SHALL OPERATE PER MANUFACTURE'S SEQUENCES TO MAINTAIN THE SPACE TEMPERATURE SETPOINT (ADJ.) UPON A FURTHER CALL FOR HEAT, THE UNIT'S FAN SPEED SHALL BE INCREASED FROM LOW TO MEDIUM AND MEDIUM TO HIGH, AS REQUIRED TO
MAINTAIN THE SPACE TEMPERATURE SETPOINT.
DURING THE COOLING MODE, UPON A CALL FOR COOLING FROM THE SPACE THERMOSTAT, THE FAN COIL UNIT SHALL OPERATE PER THE MANUFACTURES SEQUENCES TO MAINTAIN THE SPACE TEMPERATURE SETPOINT (ADJ.). UPON A FURTHER CALL FOR COOLING, THE UNITS FAN SPEED SHALL BE INCREASED FROM LOW TO MEDIUM AND MEDIUM TO
HIGH, AS REQUIRED TO MAINTAIN THE SPACE TEMPERATURE SETPOINT.
UPON LOSS OF POWER TO THE UNIT OR FAN STATUS FAILURE, THE APPROPRIATE ALARM SIGNAL SHALL BE
TRANSMITTED TO THE MAIN SYSTEM CONTROLLER
SPACE
THERMOSTAT
COIL
FILTER
HEAT PUMP & FAN COIL UNITS
APPLICATION TABLE
TYPICAL OF ALL FCU'S AND HP
HP
FAN SPEED
SUPPLY AIR
H-C
DX
RETURN AIR
FCU S
T
N.T.S.1 ROOF PIPE SUPPORT DETAIL
ROOF
GALVANIZED
CHANNEL
7/8" Ø RODS
(TYPICAL)
CONTINUOUS VAPOR
BARRIER (TYPICAL)
LOCK NUT (TYPICAL)
FREE TO SLIDE
ON ROD
LOCK NUT (TYP)
INSULATE PER
SPECS
PIPE GUIDE (TYP)
1" SPACE EACH SIDE
FOR PIPE
EXPANSION.
(TYP)
PREFABRICATED
EQUIPMENT
SUPPORT REFER TO
DETAIL
1/2 SECTION X 10"L
LOAD BEARING.
INSULATE PER SPEC
(TYPICAL)
120°, 14 GA, 8"L
SHEETMETAL.
SADDLE (TYP)
10" MIN.
18" MIN.
N.T.S.2 VARIABLE REFRIGERANT FLOW PIPING DETAIL
THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR POWER WIRING TO THE FCU AND HP UNITS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE POWER FEED TO THE HP UNIT, FUSED DISCONNECT AND WIRING TO THE HP UNIT. THE ELECTRICAL CONTRACTOR SHALL PROVIDE POWER FEED TO THE FCU, NON-FUSED DISCONNECT AND WIRING TO FCU. THE CONTROL WIRING BETWEEN FCU AND HP UNIT SHALL BE PROVIDED BY THE ATC CONTRACTOR.
THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR POWER WIRING TO THE HP UNIT, FUSED DISCONNECT AND WIRING TO THE HP UNIT. THE LOW OR LINE VOLTAGE CONTROL/FAN POWER WIRING BETWEEN THE HP UNIT AND
THE FCU SHALL BE PROVIDED BY THE ATC CONTRACTOR.
1. SIZE PIPING PER EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.
2. ALL INTERIOR PIPING SHALL BE CONCEALED IN CEILINGS AND WALLS..
3. FURNISH AND INSTALL ALL REFRIGERANT VALVES AND SPECIALTIES REQUIRED BY MANUFACTURER.
4. PROVIDE WEATHERTIGHT SEAL AT ALL PIPING PENETRATIONS. COORDINATE PENETRATIONS WITH G.C. AND
ALL ASSOCIATED TRADES AS REQUIRED.
5. SPLIT SYSTEM MANUFACTURERS UTILIZE DIFFERENT WIRING CONFIGURATIONS. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THE WIRING REQUIREMENTS OF THE SHOP DRAWING
APPROVED EQUIPMENT WITH THE ELECTRICAL CONTRACTOR.
6" CONTRETE PAD BY G.C.
(FOR GROUND INSTALLATION)
FLEX
CONN. (TYP)
REFER TO PIPING
PENETRATION DETAIL
WHERE APPLICABLE
A.C. CONDENSATE DRAIN
WITH P-TRAP. PIPE TO DRAIN.
PROVIDE A.C. CONDENSATE PUMP
AS REQUIRED.
THERMAL EXPANSION VALVE AND
DISTRIBUTOR BY COIL MANUFACTURER
RUN REFRIG. PIPING THROUGH
WALL SLEEVE WHERE APPLICABLE
FILTER/DRIER
REFRIGERANT
VALVE (TYPICAL)
NOTES:
A. SINGLE FEED SYSTEM
B. DUAL FEED SYSTEM
FCU
(INDOOR UNIT)
RLL
RGL
HP
(OUTDOOR UNIT)
SEE NOTE 5
POWER WIRING TO ACCU
BY E.C SEE NOTE 5.
SEE NOTE 5
N.T.S.3 TYPICAL REFRIGERANT PIPING INSULATION DETAIL
REFRIGERANT PIPE
SCALE: N.T.S.1 Tech Tower Key Plan
ARCHITECT
MECHANICAL ELECTRICAL
PLUMBING ENGINEERING
STAMP
REVISIONS
NUMBER DATE DESCRIPTION
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
BLW ENGINEERS INC.
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
KEY PLAN
3/21/2022
MASSBAY
COMMUNITY COLLEGE
TECH TOWER 1919
ELEVATOR
MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
100% BID SET
MECHANICAL
SCHEDULES, DETAILS
& SEQUENCE OF
CONTROLS
H0-02
AREA OF NEW WORK
AutoCAD SHX Text ONE- PIECE CLOSED CELL, ELASTOMERIC OR PVC PIPE INSULATION (OVERLAP ALL JOINTS AND SEALS PER INSULATION MANUFACTURER'S RECOMMENDATIONS)
AutoCAD SHX Text
REFRIGERANT PIPE
AutoCAD SHX Text PROVIDE UV RESISTANT JACKET OR PIPE GUARD WHERE EXPOSED TO ATMOSPHERE (OVERLAP AND SEAL ALL JOINTS)
ELEVATOR
MACHINE
SCALE: 1/4"=1'-0"1 Elevator Machine Room Demo Plan
WALL MOUNT FAN COIL
E.T.B.R.
CD
HEAT PUMP
E.T.B.R.
MOTORIZED
FIRE/SMOKE
DAMPER
E.T.R.
PIPE
E.T.R.
FS
UP
ELEVATOR
MACHINE
SCALE: 1/4"=1'-0"2 Elevator Machine Room Plan
CD
FCU-1
TR-36x12
1 2
MOTORIZED
FIRE/SMOKE
DAMPER
E.T.R.
EXISTING PIPE
T
FS
HVAC DEMO NOTES
1. REPAIR AND PATCH WALL AS NEEDED AFTER UNIT REMOVAL.
2. REPAIR AND PATCH FLOOR AS NEEDED AFTER GRILLE REMOVAL.
3. REPAIR EXISTING PENETRATIONS FOR REFRIG. PIPING.
HVAC NEW WORK NOTES
1. PROVIDE 1' SEPARATION FROM EXISTING PIPE AND NEW FCU-1.
2. USE EXISTING WALL PENETRATIONS FOR NEW REFRIG. PIPING.
3. EXTEND PIPE TO EXTERIOR WALL AND APPROX. 40'-0" DOWN TO LOWER TECH
TOWER ROOF.
4. NEW 1" CONDENSATE PIPING SHALL BE PLACED IN EXISTING CONDENSATE
PENETRATION AND DRAIN LOCATION.
5. HP-1 TO BE MOUNTED TO 24" BIG-FOOT STAND, OR MANUFACTURER'S
EQUIVALENT.
6. HP-1 AND MOUNT TO BE SECURED TO TECH TOWER LOWER ROOF.
7. PROVIDE APPROX. 120'-0" TOTAL REFRIGERANT PIPING FROM HP-1 TO FCU-1.
HP-1
EXISTING ACCUs
TO REMAIN
APPROX. 40'-0" VERTICAL RISE
TO NEW WALL PENETRATION.
SCALE: 1/4"=1'-0"3 Tech Tower Lower Roof Plan
ARCHITECT
MECHANICAL ELECTRICAL
PLUMBING ENGINEERING
STAMP
REVISIONS
NUMBER DATE DESCRIPTION
58 WINTER STREET
BOSTON, MA 02108
Phone: 617-357-5335 Fax: 617-354-5654 www.TaylorBurns.com
BLW ENGINEERS INC.
311 GREAT ROAD
LITTLETON, MA 01460
Phone:978-486-4301 Fax:978-428-0067 www.blwengineers.com
KEY PLAN
3/21/2022
MASSBAY
COMMUNITY COLLEGE
TECH TOWER 1919
ELEVATOR
MODERNIZATION
MASSBAY COMMUNITY COLLEGE
50 OAKLAND STREET
WELLESLEY MA 02481
100% BID SET
MECHANICAL
PLANS
H1-01
GENERAL NOTES
1. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR MOUNTING HEIGHTS AND EXACT LOCATIONS OF ALL DEVICES.
2. PERFORM WORK AND PROVIDE MATERIALS AND EQUIPMENT TO MAKE INSTALLATION COMPLETE IN EVERY DETAIL UNDER THIS CONTRACT
WHETHER OR NOT SPECIFICALLY SHOWN ON DRAWINGS.
3. ALL CONDUIT, WIRING AND ELECTRICAL EQUIPMENT SHALL BE INSTALLED AND GROUNDED IN ACCORDANCE WITH THE LATEST STANDARDS
OF THE NATIONAL & STATE ELECTRICAL CODES AND ANY APPLICABLE LOCAL REGULATIONS.
4. ALL FLOOR, MASONRY WALLS AND STRUCTURAL CEILING PENETRATIONS SHALL BE SLEEVED.
5. PROVIDE FIRE/MOISTURE SEAL FOR WALL, FLOOR OR CEILING PENETRATIONS.
6. DO NOT LAY CABLES OR RACEWAY ON, OR SUPPORT FROM SUSPENDED CEILING OR PIPING AND DUCTWORK.
7. OUTLET BOXES SHALL BE MOUNTED FLUSH. CONDUIT SHALL BE RUN CONCEALED. WHERE WALLS ARE BLOCK, DEVICES AND WIRING SHALL BE SURFACE MOUNTED. PROVIDE WIREMOLD OR EQUAL TO SURFACE MOUNTED RACEWAY WITH FINISHED BOXES.
8. NO CONDUIT SMALLER THAN 3/4 INCH ELECTRICAL TRADE SIZE SHALL BE USED, UNLESS SPECIFICALLY CALLED FOR ON THE DRAWINGS.
9. ALL WIRING WITHIN UTILITY CLOSETS MAY BE IN SURFACE MOUNTED CONDUIT. EMT MAY BE UTILIZED.
10. FLEXIBLE CONDUIT CONNECTIONS SHALL BE A MAXIMUM OF 6'-0".
11. MC TYPE CONDUCTOR WITH INTEGRAL GROUND WIRE MAY BE UTILIZED FOR POWER AND LIGHTING CIRCUITS. MC CABLE SHALL BE
UTILIZED ONLY WHERE COMPLETELY CONCEALED AND INSTALLED IN ACCORDANCE WITH CODE.
12.
STEEL OR FIRE-RATED ELECTRICAL BOXES (SWITCHES, OUTLETS, JUNCTION BOXES, ETC.) SHALL BE PROVIDED AND INSTALLED IN ALL FIRE RATED ASSEMBLIES AS IN ACCORDANCE WITH BUILDING AND ELECTRICAL CODES. UL LISTED MOLDABLE PUTTY PADS OR FIREBLOCK/SPRAY FOAM INSULATE SHALL BE USED TO SEAL ALL ANNULAR SPACES/PENETRATIONS AROUND OUTLET BOXES. FIRE RATED ASSEMBLIES INCLUDE EXTERIOR WALLS, FIRE-RATED WALLS, FLOOR/CEILING ASSEMBLIES AND ROOF/CEILING ASSEMBLIES.
13.
RECESSED ELECTRICAL ENCLOSURES SUCH AS BUT NOT LIMITED TO; PANELBOARDS, LOW VOLTAGE MEDIA CENTERS, ETC. SHALL BE PROVIDED WITH FIRE-RATED BOXES WHERE INSTALLED IN FIRE-RESISTANCE-RATED ASSEMBLIES. REFER TO ARCHITECTURAL PLANS FOR
LOCATIONS OF FIRE-RATED ASSEMBLIES.
14.
ALL EQUIPMENT AND WIRING ON DWGS IS SHOWN DIAGRAMMATICALLY. EXACT LOCATION AND METHOD OF SUPPORT SHALL BE DETERMINED IN THE FIELD, EXCEPT WHERE SPECIFIC DIMENSIONS AND DETAILS ARE SHOWN. ALL CONDUIT RUNS SHALL BE RIGIDLY
SUPPORTED.
15.
COORDINATE WITH ARCHITECTURAL FURNITURE LAYOUTS FOR EXACT LOCATION OF WALL MOUNTED POWER AND COMMUNICATIONS DEVICES. COORDINATE ALL LIGHTING FIXTURES, UNDER CABINET LIGHTING FIXTURES AND SWITCH LOCATIONS WITH ARCHITECTURAL
REFLECTED CEILING PLANS AND ELEVATIONS.
LIGHTING NOTES
1. ALL CONDUIT, FIXTURES AND OUTLETS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION AND METHOD OF SUPPORT SHALL BE
DETERMINED IN THE FIELD, EXCEPT WHERE SPECIFIC DIMENSIONS AND DETAILS ARE SHOWN.
2. ALL LIGHTING FIXTURE SPACING DIMENSIONS AND MOUNTING HEIGHTS ARE RECOMMENDED LOCATIONS. SLIGHT VARIATIONS WHERE
NECESSARY TO AVOID INTERFERENCE SHALL BE DETERMINED IN THE FIELD.
3. WHERE REQUIRED, ADDITIONAL SUPPORT STEEL FOR THE LIGHTING INSTALLATION SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL
CONTRACTOR. SEISMIC RESTRAINTS SHALL BE INCLUDED AS PER STATE BUILDING CODE.
4. PROVIDE SEPARATE UN-SWITCHED NEUTRAL TO ALL EXIT SIGNS, EMERGENCY BATTERY UNITS AND EMERGENCY LIGHT FIXTURES
CONTAINING EMERGENCY BALLASTS.
5.
FIRE-RATED BOXES/ENCLOSURES FOR RECESSED LIGHTING FIXTURES SHALL BE PROVIDED AND INSTALLED IN FIRE-RATED ASSEMBLIES AS IN ACCORDANCE WITH BUILDING AND ELECTRICAL CODES. FIRE-RATED ASSEMBLIES INCLUDE; FIRE-RATED WALLS, FLOOR/CEILING ASSEMBLIES AND ROOF/CEILING ASSEMBLIES. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE-RATED ASSEMBLIES.
POWER NOTES
1. ALL CONDUITS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION AND METHOD OF SUPPORT SHALL BE DETERMINED IN THE FIELD, EXCEPT WHERE SPECIFIC DIMENSIONS AND DETAILS ARE SHOWN. ALL CONDUIT RUNS SHALL BE RIGIDLY SUPPORTED.
2. NEC - 406.12 TAMPER-RESISTANT RECEPTACLES - IN ALL AREAS SPECIFIED IN 406.12 PARAGRAPHS (1-7) AND ASSEMBLY SUBSETS LISTED IN NEC 518.2, ALL NONLOCKING-TYPE, 125 VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED TAMPER RESISTANT RECEPTACLES.
3.
CONDUCTORS AND CABLE SHALL BE MINIMUM #12 AWG, 600 VOLT, COPPER WITH TYPE THHN/THWN INSULATION. PROVIDE SEPARATE GREEN GROUND IN ALL FEEDERS. WIRE SIZE #8 AWG AND LARGER SHALL BE STRANDED, #10 AWG AND SMALLER SHALL BE SOLID. COLOR CODE CONDUCTORS BLACK, RED, BLUE, WITH WHITE NEUTRAL AND GREEN GROUND EXCEPT AS NOTED FOR 120 VOLT.
4. ELECTRICAL CONTRACTOR SHALL CONFIRM ALL NEMA CONFIGURATIONS AND REQUIRED ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT
SPECIFICATIONS PRIOR TO ROUGH-IN.
DEMOLITION NOTES
1.
REFER TO THE ARCHITECTURAL DRAWINGS FOR THE FULL EXTENT OF THE SCOPE OF DEMOLITION. DISCONNECT AND MAKE SAFE ALL ELECTRICAL EQUIPMENT IDENTIFIED FOR REMOVAL ON THE HVAC, PLUMBING AND FIRE PROTECTION PLANS. THE ELECTRICAL SCOPE MAY EXTEND BEYOND THE AREA DEFINED BY THE ARCHITECTURAL DEMOLITION LIMITS TO FULLY COMPLY WITH VARIOUS REQUIREMENTS
DEFINED BY THESE NOTES.
2.
THE ELECTRICAL DEMOLITION PLANS AND DETAILS INDICATE THE GENERAL INTENT AND ARE NOT INTENDED TO SHOW ALL ITEMS TO BE REMOVED OR RETAINED. THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO THE SUBMISSION OF BIDS TO BECOME FAMILIAR WITH THE ACTUAL CONDITIONS AND EXTENT OF WORK. DEVICES AND EQUIPMENT LOCATED ON WALLS AND/OR CEILINGS TO BE REMOVED SHALL BE DISCONNECTED AND MADE SAFE. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE OF ANY
UNANTICIPATED HIDDEN CONDITIONS ENCOUNTERED DURING DEMOLITION.
3.
THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ALL SYSTEMS OR BUILDING COMPONENTS DAMAGED DURING THE EXECUTION OF THE WORK. DAMAGE SHALL INCLUDE BUT NOT BE LIMITED TO DESTRUCTION OR DISPOSAL OF ITEMS INTENDED TO
REMAIN OR TO BE SALVAGED.
4.
THE ELECTRICAL CONTRACTOR SHALL CIRCUIT TRACE AND LABEL ALL EXISTING BRANCH CIRCUITS AND FEEDERS WITHIN THE AREA OF DEMOLITION SCOPE PRIOR TO DE-ENERGIZING AND DISCONNECTION. ALL CIRCUITS WITHIN PANELBOARDS IDENTIFIED FOR REMOVAL SHALL BE TRACED AND LABELED TO ENSURE THAT NO AREA OUTSIDE THE DEMOLITION SCOPE LIMIT IS AFFECTED.
5.
THE ELECTRICAL CONTRACTOR SHALL IDENTIFY ALL BRANCH CIRCUITS, FEEDERS AND SYSTEM COMPONENTS, WHICH ARE TO REMAIN WITHIN THE AREA OF DEMOLITION SCOPE. THERE SHALL BE NO INTERRUPTION OF SERVICE TO ANY AREA OUTSIDE THE SCOPE LIMITS WITHOUT APPROVAL FROM THE OWNER'S REPRESENTATIVE. EXISTING EQUIPMENT TO REMAIN SHALL BE LEFT IN A CODE COMPLIANT
MANNER.
6.
THE ELECTRICAL CONTRACTOR SHALL DE-ENERGIZE AND REMOVE ALL CONDUCTORS AND RACEWAYS TO THEIR POINTS OF ORIGIN WITHIN THE AREA OF DEMOLITION SCOPE. ITEMS IDENTIFIED FOR DEMOLITION SHALL NOT BE ABANDONED IN PLACE. RACEWAYS THAT ENTER MASONRY WALLS AND FLOORS SHALL BE CUT FLUSH AT THE SURFACE FOR PATCHING BY OTHERS. ALL CIRCUIT BREAKERS ASSOCIATED
WITH THE DEMOLITION SCOPE SHALL BE DE-ENERGIZED AND LABELED SPARE.
7.
THE ELECTRICAL CONTRACTOR SHALL TEMPORARILY SUPPORT ALL ITEMS TO REMAIN THAT ARE AFFECTED BY THE DEMOLITION OF BUILDING STRUCTURAL COMPONENTS (WALLS, CEILINGS, ETC.). TEMPORARILY SUPPORTED ITEMS SHALL BE PERMANENTLY SUPPORTED
AND INSTALLED WHEN FINALIZED STRUCTURES ARE IN PLACE.
8. ALL REMOVED ITEMS SHALL BE LEGALLY DISPOSED OF UNLESS IDENTIFIED FOR REUSE. THE OWNER'S REPRESENTATIVE SHALL INSPECT ALL RETAINED ITEMS PRIOR TO PLACEMENT IN THE IDENTIFIED STORAGE LOCATION BY THE ELECTRICAL CONTRACTOR.
9.
THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN FULLY FUNCTIONAL DURING THE ENTIRE DEMOLITION AND CONSTRUCTION PERIOD.
REUSE OF EXISTING FIRE ALARM SYSTEM RACEWAYS SHALL NOT BE ALLOWED. ALL REQUIRED SYSTEM SHUTDOWNS SHALL BE COORDINATED WITH AND APPROVED BY THE OWNER'S…
This is the start of the file's text. The full file is on GovTribe.