2-Site Civil Improvements and Building Safety Upgrades Project Drawings 4644.029.pdf
PDF 11 MB Posted
- Solicitation number
- Not on record
- Issued by
- Berks County, South Pottstown CDP, Pennsylvania
About this file
Project Drawings and Specifications Summary
This document comprises a comprehensive set of construction drawings and specifications for the Site Civil Improvements and Building Safety Upgrades project at the Township of Spring Police Department in Berks County, Pennsylvania, prepared by Entech Engineering (Project No. 4644.029). The project encompasses water infiltration remediation, ballistic security improvements including doors, windows, and glazing panels, exterior foundation waterproofing around the building perimeter, epoxy injection for groundwater infiltration mitigation in foundation soils and the elevator pit, drainage piping upgrades including an underground roof drain system and foundation drain improvements, new concrete sidewalks and site surface restoration with mulch and grass areas, erosion and sedimentation control measures, parking lot pavement mill and overlay with restriping, electrical demolition and new work, a new security camera system with associated infrastructure, and miscellaneous architectural repairs including exterior brick repointing and chimney work. The project is divided into two contracts: Contract No. 1 for General Construction and Contract No. 2 for Mechanical Construction. Sealed electronic proposals are due by 2:00 p.m. on Wednesday, June 10, 2026, via the PennBid Program, with contract award anticipated thereafter. The drawings specify detailed civil site plans, foundation drain and roof drain system layouts, concrete construction details, erosion and sediment control plans with multiple best management practices, and restoration specifications with unit prices and allowances for unforeseen conditions including additional wood framing and concrete.
The project specifications include three quantity allowances: up to 75 linear feet of non-structural pressure-treated wood framing, 50 linear feet of structural pressure-treated wood framing, and 4 cubic yards of additional concrete, all necessary due to unforeseen site conditions. Four bid alternates are identified: additional parking lot mill and overlay, brick chimney repair and capping, repointing of remaining facade brick not included in the base bid, and new downspouts with associated components. The project is subject to the Pennsylvania Prevailing Wage Act with specified wage rates for carpenters, laborers, operators, and painters effective through various dates in 2027. Bidders must submit proposals with bid bonds or certified checks equal to 10 percent of the total base bid, along with non-collusion affidavits; upon contract award, performance and payment bonds each equal to 100 percent of the contract price are required. The project receives funding support from the Department of Conservation and Natural Resources Bureau of Recreation and Conservation Growing Greener Bond Fund. All bids remain effective for 60 calendar days from the opening date, and the Township of Spring reserves the right to accept or reject any or all bids, re-advertise the contract, or waive any informality in bids received.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
2 3
C
D
1 2 3
4 5 6
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
Entech Engineering - Printed: May. 11, 2026 H:\0004644.029\04-CAD\SheetFiles\New Work\G-001.dwgLa st
E di te d by : p m cc ar ty
/1
1/
BI
D
D
IN
G C
AD
TO
W
N
SH
IP
O
F
SP
R
IN
G
TO
W N
SH
IP
O F
SP
R
IN
G
, B
ER
KS
C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
SI
TE
C
IV
IL
IM
PR
O
VE
M
EN
TS
A N
D B
U
IL
D
IN
G S
AF
ET
Y U
PG
R
AD
ES
G-001
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
DRAWING NO.
4644.029
CAD
KJL
MAH
AS NOTED
/1
1/
D
R
AW
IN
G
IN
D
EX
, G
EN
ER
AL
P
R O
JE
C
T N
O
TE
S, D
R
AW
IN
G
C O
N
VE
N
TI
O N
S
AN
D M
AP
S
G
EN
ER
AL
00 1000' 2000'
SCALE:1 1" = 1000'
LOCATION / TOPOGRAPHICAL MAP
REFERENCE: USGS 7.5 MINUTE SERIES (TOPOGRAPHIC MAP) SINKING SPRING, PENNSYLVANIA
MAILING ADDRESS:
2850 WINDMILL ROAD
SINKING SPRING, PA. 19608
TOWNSHIP OF SPRING
POLICE BUILDING
LAT: 40° 19' 4.0"N
LONG: -76° 00' 18.3"W
GENERAL PROJECT NOTES
MAY 11, 2026
DRAWING CONVENTIONS
SECTION INDICATOR
DETAIL INDICATOR
A X-301
A X-301
X-501
SCALE:1 1" = 1'-0"
DRAWING TITLE
DRAWING NUMBER
SECTION LETTER
IDENTIFICATION NUMBER/LETTER
DRAWING TITLE
A
SHEET KEYNOTE SYMBOL
DEMOLITION KEYNOTE
SYMBOL
PHOTOGRAPH INDICATOR
PHOTOGRAPH
IDENTIFICATION
DRAWING NUMBER
DETAIL NUMBER
A
TEXT
INDICATES EXIST
CONDITIONS/FEATURES
INDICATES NEW
WORK/FEATURES
DENOTES REFERENCE TO ENLARGED
PLANS WITH DRAWING NUMBER
INDICATED
X
XXX
TOWNSHIP OF SPRING
TOWNSHIP OF SPRING POLICE BUILDING RENOVATION
TOWNSHIP OF SPRING, BERKS COUNTY, PENNSYLVANIA
1. THE LOCATION AND DIMENSIONS OF ALL SITE FEATURES SHOWN ARE
APPROXIMATE AND MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR
PRIOR TO BIDDING.
2. CONTRACTOR SHALL USE, MAINTAIN AND PROVIDE ADEQUATE, PROPER
SHORING DEVICES ON SITE AT ALL TIMES. CONTRACTOR SHALL CONFORM
TO ALL LOCAL, STATE AND FEDERAL REGULATIONS.
SCALE:2 NONE
VICINITY MAP
CODE SUMMARY
ISSUED FOR
BIDDING
2018 (IBC) INTERNATIONAL BUILDING CODE
2018 (IEBC) INTERNATIONAL EXISTING BUILDING CODE
2018 (IMC) INTERNATIONAL MECHANICAL CODE
2018 (IPC) INTERNATIONAL PLUMBING CODE
2018 (IECC) INTERNATIONAL ENERGY CONSERVATION CODE
2018 (IFC) INTERNATIONAL FIRE CODE
2017 (NEC) NATIONAL ELECTRICAL CODE (NFPA-70)
2017 (ICC) INTERNATIONAL CODE COUNCIL
(ANSI A117.1, CHAPTER 11, IBC 2021 ACCESSIBILITY REQUIREMENTS)
IEBC CHAPTER 4: REPAIRS
BUILDING COMPONENTS BEING REPAIRED:
- DRYWALL
- COLUMNS (EXTERIOR)
- FRONT PORCH
IEBC CHAPTER 7: ALTERATION - LEVEL 1
IBC CHAPTER 3: USE AND OCCUPANCY CLASSIFICATION
SECTION 302 - CLASSIFICATION
SECTION 304.1 - BUSINESS GROUP B
CONSTRUCTION CLASSIFICATION: IIB - FULLY SPINKLERED
IBC CHAPTER 5: GENERAL BUILDING HEIGHTS AND AREAS
SECTION 503 – GENERAL BUILDING HEIGHTS AND AREAS
SECTION 504 – BUILDING HEIGHT AND NUMBER OF STORIES
TABLE 504.3 - ALLOWABLE BUILDING HEIGHT: 75'
TABLE 504.4 - ALLOWABLE NUMBER OF STORIES: 4
SECTION 506 – BUILDING AREAS
TABLE 506.2 - ALLOWABLE AREA: 23,000 SF PER FLOOR
PERMITTED FOR TYPE IIB CONSTRUCTION:
B OCCUPANCIES: 2 STORIES, 30' HIGH, 23,000 SF
ACTUAL: (2) STORY ABOVE GRADE, W/ BASEMENT 19,010 SF,
6,200 SF (BASEMENT)
6,467 SF (FIRSTFLOOR)
6,343 SF (SECOND FLOOR)
FULLY SPRINKLERED
IBC CHAPTER 6: TYPES OF CONSTRUCTION
EXISTING SPRINKLER SYSTEM (FULL)
SECTION 601 - GENERAL
TABLE 601: TYPE IIB (PERMITTED FOR TYPE V-B CONSTRUCTION)
TABLE 601 - FIRE RESISTANCE RATING REQUIRED FOR BUILDING
ELEMENTS CONSTRUCTION TYPE V-B – “0” HOURS FOR ALL BUILDING
ELEMENTS
SECTION 602 - CONSTRUCTION CLASSIFICATION
SECTION 602.5 - TYPE II CONSTRUCTION IS THAT TYPE OF
CONSTRUCTION IN WHICH THE STRUCTURAL ELEMENTS, EXTERIOR
WALLS, AND INTERIOR WALLS ARE OF ANY MATERIALS PERMITTED BY
THIS CODE.
IBC CHAPTER 8: INTERIOR WALL AND CEILING FINISHES
SECTION 803, TABLE 803.13
CLASS C FINISHES: ROOMS AND ENCLOSED SPACES
IBC CHAPTER 9: FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 903 - AUTOMATIC SPRINKLER SYSTEMS
SECTION 903.2.1 – WHERE REQUIRED:
SPRINKLER SYSTEM IS NOT REQUIRED IN USE GROUP B.
SECTION 906 - PORTABLE FIRE EXTINGUISHERS
SECTION 906.1 - REQUIRED FOR B OCCUPANCIES
TABLE 906.3 (1)
MIN. 2-A EXTINGUISHER RATINGS
MIN. 1-A PER 3000 SF OF FLOOR
MAXIMUM 75' TRAVEL DISTANCE TO EXTINGUISHER
OR
TABLE 906.3 (2)
MIN. 5-B EXTINGUISHER RATINGS W/ 30' MAX TRAVEL
MIN. 10-B EXTINGUISHER RATINGS W/ 50' MAX TRAVEL
IECC CHAPTER 3: GENERAL REQUIREMENTS
SECTION 301 - CLIMATE ZONES
TABLE C301.1 – BERKS COUNTY, PENNSYLVANIA - ZONE 5A
IECC CHAPTER 4: COMMERCIAL ENERGY EFFICIENCY
SECTION 402 - BUILDING ENVELOPE REQUIREMENTS
TABLE R402.1.3 -OPAQUE THERMAL ENVELOPE INSULATION
COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD:
1. WALLS, MASS, ZONE 5A: R-13+R-3.8CI OR R-20, PROVIDED.
2. ATTIC AND OTHER, ZONE 5A: R-38, PROVIDED.
3. JOIST/FRAMING BELOW GRADE: R-30.
4. SLAB-ON-GRADE FLOORS, ZONE 5A: R-10, 24IN. BELOW
PROJECT NAME: POLICE BUILDING REHABILITATION
BUILDING: THE TOWNSHIP OF SPRING POLICE DEPARTMENT
PROJECT LOCATION: 2800 SHILLINGTON ROAD, READING, PA 19608
OWNER: SPRING TOWNSHIP
DESIGN PROFES: ENTECH ENGINEERING, INC.
201 PENN STREET
PO BOX 32
READING, PENNSYLVANIA 19603
PHONE: 610.373.6667 / FAX: 610.373.7537
PROJECT TYPE: RENOVATION
PROJECT SITE
SITE CIVIL IMPROVEMENTS AND BUILDING SAFETY UPGRADES
DESIGN PA ONE CALL
UTILITY RESPONSE ADDRESS CONTACT INFORMATION CONTACT PERSON
TOWNSHIP OF SPRING 2850 WINDMILL RD
READING, PA. 19608 610-678-5393 OFFICE PERSONNEL
PENNSYLVANIA ELECTRIC CO 341 WHITE POND DRIVE
AKRON, OH. 44320
madams@firstenergycorp.com
330-252-4013 MELLYSSA ADAMS
PPL ELECTRIC UTILITIES CORPORATION 4810 LYCOMING MALL
MONTOURSVILLE, PA. 17754
pdseitzer@pplweb.com
570-368-5394 PAMELA SEITZER
PENNSYLVANIA AMERICAN WATER 171 W JOHNSON HWY
NORRISTOWN, PA. 19401
siti.yearwood@amwater.com
610-292-3575 SITI YEARWOOD
UGI UTILITIES INC 225 MORGANTOWN RD
READING, PA. 19611
kzielaskowski@ugi.com
610-736-5571 KURT ZIELASKOWSKI
VERIZON PENNSYLVANIA LLC N/A 1call-verizon-pade@verizon.com OFFICE PERSONNEL
1-800-242-1776
(TOLL FREE)
"Pa. Law requires advance notification"
PA ONE CALL FOR FINAL DESIGN
COORDINATE PA ID# 13274328
SERIAL NUMBERS ISSUED:
1-800-242-1776
PE
NN
SY
LV
ANIA ONE CALL SYSTEM
, INC
STOP -CALL BEFORE YOU D
IG
20260542195 (FINAL DESIGN)
DRAWING INDEX CONTRACT NO. 01
DWG. NO. DRAWING DESCRIPTION/TITLE
GENERAL
G-001 DRAWING INDEX, GENERAL PROJECT NOTES,
DRAWING CONVENTIONS AND MAPS
G-002 DRAWING LEGENDS, SYMBOLS, AND ABBREVIATIONS
G-101 AERIAL SITE PLAN - EXISTING CONDITIONS
DEMOLITION
GD-401 SITE DEMOLITION PLAN
EROSION AND SEDIMENTATION
ES-101 CONTROL PLAN
ES-501 CONTROL NOTES
ES-502 CONTROL DETAILS
CIVIL
C-101 SITE PLAN
C-401 ENLARGED SITE PIPING PLAN
C-402 ENLARGED SIDEWALK PLAN
C-403 BACKFILL PLAN, DETAILS AND NOTES
C-501 CONSTRUCTION DETAILS
C-502 RESTORATION DETAILS
C-701 SPECIFICATIONS
ARCHITECTURAL
A-101 FIRST AND SECOND FLOOR - BALLISTIC PLAN
A-102 FIRST FLOOR DEMOLITION AND NEW WORK - BALLISTIC PLAN
A-103 BALLISTIC DOOR AND WINDOW DETAILS AND NOTES
A-104 BALLISTIC GLASS AND PANEL DETAILS AND NOTES
A-105 ELECTRICAL BILLBOARD PLAN AND DETAILS
A-106 FLOOR PLAN, WATERPROOFING SECTIONS, DETAILS AND NOTES
A-701 SPECIFICATIONS - 1
A-702 SPECIFICATIONS - 2
A-703 SPECIFICATIONS - 3
ELECTRICAL
ED-101 DEMOLITION FLOOR PLANS
E-101 FLOOR PLANS - NEW WORK
E-701 LEGEND, NOTES, AND SPECIFICATIONS
DRAWING INDEX CONTRACT NO. 02
DWG. NO. DRAWING DESCRIPTION/TITLE
GENERAL
G-001 DRAWING INDEX, GENERAL PROJECT NOTES,
DRAWING CONVENTIONS AND MAPS
G-002 DRAWING LEGENDS, SYMBOLS, AND ABBREVIATIONS
G-101 AERIAL SITE PLAN - EXISTING CONDITIONS
MECHANICAL
MD-101 DEMOLITION FLOOR PLANS
M-101 FLOOR PLANS
M-701 SCHEDULES, NOTES, AND SPECIFICATIONS
CONTRACT NO. 1 - GENERAL CONSTRUCTION
CONTRACT NO. 2 - MECHANICAL CONSTRUCTION
356.00
360 PROPOSED GRADE (MAJOR)
PROPOSED STORM DRAIN
PROPOSED PAVED SURFACE
ROCK CONSTRUCTION ENTRANCE
PROPOSED INLET
PROPOSED STORM DRAIN MANHOLE
PROPOSED YARD HYDRANT
PROPOSED GATE VALVE
PROPOSED PLUG VALVE
PROPOSED MECHANICAL JOINT FITTING
LIMIT OF DISTURBANCE
Bh SwD
B-5
EXISTING FACILITY TO BE REMOVED
EXISTING FACILITY TO BE MODIFIED
NEW BUILDING FACILITIES
PROPOSED MACADAM ACCESS
ROAD/ STONE DRIVEWAY
EROSION CONTROL BLANKET STEEP SLOPES
PROPOSED HYDRANT
RIP RAP OUTLET PROTECTION
FILTER BAG INLET PROTECTION
PROPOSED CURB STOP
PROPOSED WATER METER & METER BOXWMB
CS
PROPOSED SANITARY MANHOLE
356 PROPOSED GRADE (MINOR)
EROSION CONTROL SWALE MATTING
CB
YH
D
S
TEXT PROPOSED TEXT
MATCHLINE
MATCH LINE REFER TO DWG C-101
TRENCH PLUG
PROPOSED CLEAN OUTCO
A
B
2 3
C
D
1 2 3
4 5 6
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
Entech Engineering - Printed: May. 11, 2026 H:\0004644.029\04-CAD\SheetFiles\New Work\G-002.dwgLa st
E di te d by : m hi es te r
/1
1/
BI
D
D
IN
G C
AD
TO
W
N
SH
IP
O
F
SP
R
IN
G
TO
W N
SH
IP
O F
SP
R
IN
G
, B
ER
KS
C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
SI
TE
C
IV
IL
IM
PR
O
VE
M
EN
TS
A N
D B
U
IL
D
IN
G S
AF
ET
Y U
PG
R
AD
ES
G-002
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
DRAWING NO.
4644.029
CAD
KJL
MAH
AS NOTED
/1
1/
D
R
AW
IN
G
L
EG
EN
D
S, S
YM
BO
LS
A
N D
A
BB
R
EV
IA
TI
O N
S G
EN
ER
AL
CIVIL LEGEND ABBREVIATIONS LEGEND
REFRIGERATOR
RESILIENT BASE
REINFORCE(D), REINFORCING
RISER, RADIUS
PAPER TOWEL DISPENSER
POINT, PRESSURE TREATED
PAPER TOWEL RECEPTACLE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PLUMBING CONTRACTOR
SOLID SURFACE MATERIAL
SPECIAL WALL COVERING
RAIN WATER CONDUCTOR
ROUGH OPENING, ROOF OPENING
SOLID POLYMER FABRICATIONS
SQUARE FOOT
SPECIFICATION
TOILET PARTITION
VENT THROUGH ROOF
VINYL COMPOSITION TILE
VINYL COVE BASE
VENEER PLASTER, VAPOR PROOF
UNLESS NOTED OTHERWISE
TOILET PAPER DISPENSER
TOP OF SLAB
TOP OF STEEL
TOP OF WALL
TOP OF MASONRY
FINISHED
ABOVE
PLUMBING
MOUNTING
ESTIMATE
EQUIPMENT
EXHAUST
EXISTING
EQUAL
EACH WAY
FIRE ALARM
FLOOR DRAIN
EXTERIOR
EXPANSION
ELECTRIC WATER COOLER
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FINISHED BY OTHERS
FINISH FLOOR ELEVATION
FIRE HOSE CABINET
CONTRACTOR INSTALLED
NON-FUSED DISCONNECT SWITCH
OPPOSITE
NUMBER / NORMALLY OPEN
NOMINAL
NOT IN CONTRACT
NOT TO SCALE
NOT APPLICABLE
OPENING
OVERHEAD
OVERALL / OUTSIDE AIR
OUTSIDE DIAMETER
OWNER FURNISHED
ON CENTER
WITHOUT
WOOD
WITH
UNDERCUT
VERTICAL
TYPICAL
AMERICAN STANDARD TESTING MATERIAL
CEILING
CLOSET
COLUMN
CONCRETE
CONSTRUCTION
CORRIDOR
COURSE(S)
CURB STOP, CORPORATION STOP
CARPET
CONTRACTOR
CONTINUOUS
CLEAN ROOM WALL PANEL
CONCRETE MASONRY UNIT
DOWN SPOUT
DRAWING
DOOR, DRAIN
DIAMETER
DIMENSION
EMERGENCY
ELECTRIC(AL)
ELEVATION
EACH
DRINKING FOUNTAIN
EXPANSION JOINT
EXPANSION JOINT
ELECTRICAL CONTRACTOR
DETAIL
ADJUSTABLE
ALTERNATE
ACOUSTIC
ABANDON
ASPHALT
APPROXIMATE
ALUMINUM
ACOUSTIC TILE CEILING
ABOVE FINISHED FLOOR
ARCHITECTURAL WOOD INSTITUTE
BOTTOM FOUNDATION ELEVATION
ARCHITECTURAL
BEAM
BRICK
BASEMENT
BOTTOM
BUILDING
BLOCKING
BITUMINOUS
BUILT UP ROOF
CENTERLINE
CATCH BASIN
CONTROL JOINT
CABINET
CENTER TO CENTER
AIR CONDITIONING
MECHANICAL/ELECTRICAL/PLUMBING
LOW POINT, LIGHTING PANEL
MEDIUM DENSITY OVERLAY
JANITOR, JANITOR'S CLOSET
LOUVER
MAXIMUM
METAL
MECHANICAL
MINIMUM
MECHANICAL JOINT
MOUNT(ED)
MISCELLANEOUS
MANUFACTURER
MANUFACTURING
INTERIOR
INSIDE DIAMETER
INFORMATION
ISOLATION JOINT
JOINT
LENGTH, LONG
LAMINATE(D)
LINEAR FOOT
HVAC CONTRACTOR
INSULATE, INSULATION
SUSPENDED
SYSTEM
TREAD, TOP
THICK(NESS)
TERRAZZO
TELEPHONE
TEMPERED
STEEL
STANDARD
STRUCTURAL
SHEET VINYL
STORAGE
SECTION
SIMILAR
SQUARE
SHOWER
ROOM
RUBBER TILE
SANITARY
SCHEDULE
GROUND
HEADER
HANDICAP(PED)
HOLLOW METAL
HARDWARE
HIGH
HEIGHT
HIGH POINT / HORSEPOWER
HANDRAIL
HORIZONTAL
GYPSUM WALLBOARD
HEATING, VENTILATING &
FLOOR
FIXTURE
FACE OF FINISH
FOUNDATION
FOOTING
GAUGE
FIREPROOF(ING)
GALVANIZED
GRAB BAR
FACE OF STUDS
GENERAL CONTRACTOR
FACE OF CONCRETE
FACE OF MASONRY
RETURN
REFERENCE
REQUIRED
REVISION
RESILIENT
RADIUS
QUANTITY
QUARRY TILE
RETURN AIR
ROOF DRAIN
PAIR
PARTITION
PAINTED
PLATE
PLASTER
PLACES
CLEAN-OUT
PREMOLDED JOINT FILLER
LEVEL / LAMINATED VENEER LUMBER
DEPARTMENT
BALANCING VALVE
CUBIC FEET PER MINUTE
AIR CONDITIONING CONDENSATE
CHLORINATED PVC PIPE
DOMESTIC COLD WATER
DOWN
ENTERING AIR TEMPERATURE
ENTERING DRY BULB
EXTERNAL STATIC PRESSURE
ENTERING WET BULB
ENTERING WATER TEMPERATURE
INVERT
JUNCTION BOX
KILOWATT
LEAVING AIR TEMPERATURE
MECHANICAL CONTRACTOR
NORMALLY CLOSED
PANEL
PRESSURE REGULATING VALVE
POLYVINYL CHLORIDE
REVOLUTIONS PER MINUTE
SUPPLY AIR
UNIT HEATER
VARIABLE SPEED DRIVE
VARIABLE FREQUENCY DRIVE
AIR HANDLING UNIT
ACCESS PANEL
FLEXIBLE CONNECTOR
FIN
PLBG
ABV
MTG
TOM
EST
FHC
FEE
FEC
FBO
EXP
FE
FD
FA
EXT
EQUIP
EXIST
EWC
EXH
EQ
EW
OPP
OFCI
OPNG
OC
OD
OA
OH
NFDS
NA
NO
NOM
NTS
NIC
W/O
WD
W/
TOW, TW
TYP
TOS
TPTN
VERT
VTR
UNO
VCT
VCB
UC
VP
TSL
TP
CLG
DET
EA
EMER
ELEC
EJ
EC
EL/ELEV
EXP JT
DIA,Ø
DWG
DR
DS
DIM
DF
CONT
CORR
CRWP
CPT
CRS
CS
CONTR
CONC
COL
CLO
CMU
CONST
CAB
BUR
CJ
LC
CC
CB
BRK
BSMT
BLDG
BLKG
BOT, BTM
BM
BIT
ALUM
ARCH
ASPH
ASTM
BFE
AWI
APPROX
ACT
ADJ
AFF
ALT
ATC
ABDN
LVR
MFG
MISC
MT(D)
MJ
MIN
MANUF.
MAX
MECH
MDO
MEP
MET
JAN
L
LAM
LF
LP
JT
INSUL
IJ
INFO
HC
INT
ID
SSM
STOR
SWC
STR
STD
TMPD
THK
TER
SYS
SUSP
T
TEL
STL
SV
SAN
SCH
RWC
SPEC
SHR
SPF
SECT
SIM
SQ
SF
RO
RT
RM
HORIZ
HVAC
HR
HT
H
HP
GWB
HDWR
GND
H/C
HM
HDR
FOS
GALV
FTG
FP
GC
GB
GA
FIXT
FOF
FOM
FOC
FDN
FLR
QTY
RAD
REFR.
REQD
REINF
REF
REV
RET
RES
RB
RD
QT
RA
R
PNT(D)
PLCS
PTR
PTN
PTD
PSF
PR
PT
PSI
P
PL
PC
CO
PMJF
LVL
DEPT
AHU
AP
FLEX
BV
CFM
COND
CPVC
CW
DN
EAT
DB
ESP
EWT
EWB
INV
JB
KW
LAT
MC
NC
PNL
PRV
PVC
RPM
SA
UH
VSD
VFD
MACADAMMAC
WASTE WATERWW
GALLONGAL
PLYWOODPLY
LEVEL SENSORLS
LEVEL ELEMENTLE
LEVEL TRANSDUCER / TRANSMITERLT
MASONRY OPENINGMO
DUCTILE IRON PIPEDI, DIP
CAST IRON PIPECI, CIP
UNNAMED TRIBUTARYUNT
MOTOR CONTROL PANELMCP
MICRO SCREEN CONTROL PANELMSCP
HAND SWITCHHS
FLOW INDICATING TRANSMITTERFIT
ANALYSIS INDICATING TRANSMITTERAIT
PLUG VALVEPV
STOP GATESG
OL
G
HP
J
NEW EXPOSED WIRING IN RACEWAY
NEW WIRING CONCEALED IN CEILING, WALL OR
UNDERGROUND
BRANCH CIRCUIT HOMERUN TO PANEL, NUMBER OF
ARROWS = NUMBER OF RACEWAYS. ALPHA-NUMERIC
DESIGNATION = PANEL - CIRCUIT #
CONDUIT TURNING DOWN
CONDUIT TURNING UP
DUPLEX RECEPT. MOUNTED AT ABOVE COUNTER
(COORDINATE WITH FURNITURE PROVIDER), NUMBER =
CIRCUIT # IN LOCAL 120/208V PANEL
RECEPTACLE W/ INTEGRAL GROUND FAULT CIRCUIT
INTERRUPTER MOUNTED AT 18" A.F.F., NUMBER =
CIRCUIT # IN LOCAL 120/208V PANEL
RECEPTACLE W/ INTEGRAL GROUND FAULT CIRCUIT
INTERRUPTER, AND WEATHERPROOF-WHILE-IN-USE
COVERPLATE MOUNTED AT 18" A.F.F., NUMBER =
CIRCUIT # IN LOCAL 120/208V PANEL
JUNCTION BOX
MOTOR, HORSEPOWER AS INDICATED ON PLANS
EQUIPMENT DESIGNATION REFER TO GENERAL,
MECHANICAL & PLUMBING DRAWINGS FOR
SCHEDULES
FUSE
CIRCUIT BREAKER
FUSED DISCONNECT SWITCH
NON-FUSED DISCONNECT SWITCH
PULL OUT DISCONNECT
TRANSFORMER
GENERATOR
GROUND
NORMALLY OPEN CONTACT
NORMALLY CLOSED CONTACT
OVERLOAD RELAY
CONDUCTORS NOT CONNECTED
CONDUCTORS CONNECTED
DISTRIBUTION PANELBOARD, SWITCHBOARD OR
MOTOR CONTROL CENTER, SHOWN TO SCALE ON
PLANS
DISCONNECT SWITCH, TYPE AND SIZE AS INDICATED
ON DRAWINGS
HEAT TRACE POWER CONNECTION KIT
CONTROL STATION (TYPE AS SHOWN)
PHOTO CELL
GFI,14
ELECTRICAL SYMBOL LEGEND
LP1-14
WP,GFI,14
A,13,b
AC,14
EXISTING EXPOSED WIRING IN RACEWAY
EXPLOSION PROOFXP
P
PC
PLUMBING / HVAC SYMBOL LEGEND
MANUAL MOTOR STARTER
OS CEILING MOUNTED WIRELESS MOTION SENSOR
OS CORNER MOUNTED WALL WIRELESS MOTION SENSOR
LUMINAIRE, TYPE AS INDICATED ON LUMINAIRE
SCHEDULE ON SHEET E-501. LETTER = LUMINAIRE TYPE,
NUMBER = CIRCUIT IN LOCAL 120/208V PANEL, lower case letter = SWITCH DESIGNATION
DUPLEX RECEPT. MOUNTED AT 18" A.F.F. UNLESS
OTHERWISE NOTED, NUMBER = CIRCUIT # IN LOCAL
120/208V PANEL
S3b LIGHTING SWITCH - NUMBER (WHERE USED) INDICATES SWITCH TYPE (3 = 3-WAY, ETC...), lower case letter
MATCHES CONTROLLED FIXTURES
A,13,b
SM
BTUH BRITISH THERMAL UNITS PER HOUR
CFU COLD WATER FIXTURE UNITS
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
DTW DOMESTIC TEMPERED WATER
DTWR DOMESTIC TEMPERED WATER RETURN
DN DOWN
EAT ENTERING AIR TEMPERATURE
EXH EXHAUST
EF EXHAUST FAN
ESP EXTERNAL STATIC PRESSURE
EXIST EXISTING
GPM GALLONS PER MINUTE
HFU HOT WATER FIXTURE UNITS
MAU MAKE-UP AIR UNIT
MBH 1000 BTUH
OA OUTSIDE AIR
RA RETURN AIR
SA SUPPLY AIR
SAN SANITARY
SQFT SQUARE FEET
UNION
REDUCER
PIPING UP
PIPING DOWN
THERMOSTAT
ITEM TO DEMOLISH
T
VALVE
DIRECTION OF FLOW
DUCT SECTION, SUPPLY AIR
DUCT SIZE, FIRST FIGURE IS SHOWN
DUCT SECTION, RETURN AIR
BALANCING DAMPER
24x12
DUCT SECTION, EXHAUST AIR
SANITARY SEWER
NATURAL GAS
EQUIPMENT DESIGNATION
CONNECTION TO EXISTING
SAN
G
POINT OF DISCONNECTION
AIR FLOW
CD
DOMESTIC HOT WATER PIPING
DOMESTIC COLD WATER PIPING
CONDENSATE DRAIN PIPING
HOSE BIBB
UHW UTILITY HOT WATER
RAIN LEADERRL
PROPOSED MULCH AREA
PROPOSED GRASS AREA
PROPOSED SIDEWALK AREA
PROPOSED UNDERGROUND
ROOF DRAIN SYSTEM
PROPOSED FOUNDATION DRAIN (PERFORATED)
PROPOSED FOUNDATION DRAIN (SOLID)
B
2 3
C
D
1 2 3
4 5 6
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
Entech Engineering - Printed: May. 11, 2026 H:\0004644.029\04-CAD\SheetFiles\New Work\G-101.dwgLa st
E di te d by : m hi es te r
/1
1/
BI
D
D
IN
G C
AD
TO
W
N
SH
IP
O
F
SP
R
IN
G
TO
W N
SH
IP
O F
SP
R
IN
G
, B
ER
KS
C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
SI
TE
C
IV
IL
IM
PR
O
VE
M
EN
TS
A N
D B
U
IL
D
IN
G S
AF
ET
Y U
PG
R
AD
ES
G-101
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
DRAWING NO.
4644.029
CAD
KJL
MAH
AS NOTED
/1
1/
G
EN
ER
AL
AE
R
IA
L
SI
TE
P
LA
N
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
GENERAL NOTES
SCALE:1 1" = 20'
AERIAL SITE PLAN - EXISTING CONDITIONS
00 20' 40'
1. REFER TO DRAWING G-001 FOR DRAWING INDEX, GENERAL PROJECT
NOTES, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-002 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
3. EXISTING AERIAL SITE PLAN INDICATES EXISTING CONDITIONS ONLY.
B
2 3
C
D
1 2 3
4 5 6
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
Entech Engineering - Printed: May. 11, 2026 H:\0004644.029\04-CAD\SheetFiles\New Work\GD-401.dwgLa st
E di te d by : m hi es te r
/1
1/
BI
D
D
IN
G C
AD
TO
W
N
SH
IP
O
F
SP
R
IN
G
TO
W N
SH
IP
O F
SP
R
IN
G
, B
ER
KS
C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
SI
TE
C
IV
IL
IM
PR
O
VE
M
EN
TS
A N
D B
U
IL
D
IN
G S
AF
ET
Y U
PG
R
AD
ES
GD-401
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
DRAWING NO.
4644.029
CAD
KJL
MAH
AS NOTED
/1
1/
SI
TE
D
EM
O
LI
TI
O N
P
LA
N D
EM
O
LI
TI
O N
GENERAL NOTES
A. REMOVE EXISTING CONCRETE SIDEWALK TO FACILITATE INSTALLATION
OF PROPOSED CONCRETE SIDEWALK.
B. EXISTING PAVEMENT TO BE REMOVED TO FACILITATE INSTALLATION OF
PROPOSED DRAINAGE LINES.
C. REMOVE EXISTING PORTION OF FOUNDATION DRAIN PIPING TO
FACILITATE INSTALLATION OF PROPOSED FOUNDATION DRAIN.
D. EXISTING FOUNDATION DRAIN AND ROOF LEADER PIPING TO BE CAPPED
AND ABANDONED IN PLACE.
E. REMOVE EXISTING RAILING, TEMPORARY STORE, FOR REINSTALLATION.
PROTECT RAILING FROM DAMAGE DURING REMOVAL. CONTRACTOR IS
RESPONSIBLE FOR ANY DAMAGE TO EXISTING RAILING.
- DEMOLITION KEYNOTES
1. REFER TO DRAWING G-001 FOR DRAWING INDEX, GENERAL PROJECT
NOTES, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-002 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
SCALE:1 1" = 20'
SITE DEMOLITION PLAN
00 20' 40'
D
B
B
A
A
A
C
D
D
D
C
C
C C
C
D
CC
B
B
A
B
ALTERNATE No. 1
1-1/2" PAVEMENT MILL
AND OVERLAY
GENERAL NOTES
1. THE FOLLOWING DEFINITIONS APPLY TO THE WORK:
A. REMOVE: REMOVE AND LEGALLY DISPOSE OF ITEMS EXCEPT
THOSE INDICATED TO BE REINSTALLED, SALVAGED, OR TO REMAIN
THE OWNER'S PROPERTY.
B. REMOVE AND SALVAGE: ITEMS INDICATED TO BE REMOVED AND
SALVAGED REMAIN THE OWNER'S PROPERTY. REMOVE, CLEAN,
PACK OR CRATE ITEMS TO PROTECT AGAINST DAMAGE. IDENTIFY
CONTENTS OF CONTAINERS AND DELIVER TO OWNER'S
DESIGNATED STORAGE AREA.
C. REMOVE FOR REINSTALLATION: REMOVE ITEMS INDICATED; CLEAN,
SERVICE, AND OTHERWISE PREPARE THEM FOR REUSE AND
PROTECT THEM AGAINST DAMAGE. REINSTALL ITEMS IN THE SAME
LOCATIONS OR IN LOCATIONS INDICATED ON NEW WORK
DRAWINGS.
D. EXISTING TO REMAIN: PROTECT CONSTRUCTION INDICATED TO
REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE
DEMOLITION. WHEN PERMITTED BY THE OWNER'S
REPRESENTATIVE, ITEMS MAY BE REMOVED TO A SUITABLE
PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION
AND THEN CLEANED AND REINSTALLED IN THEIR ORIGINAL
LOCATIONS.
2. THE OWNER RESERVES THE RIGHT TO SALVAGE ANY ITEMS
IDENTIFIED TO BE REMOVED. AT THE BEGINNING OF DEMOLITION
WORK THE OWNER'S REPRESENTATIVE SHALL IDENTIFY ALL ITEMS TO
BE SALVAGED.
3. DEMOLITION SHALL BE PERFORMED IN AN ORDERLY FASHION. ALL
NECESSARY PRECAUTIONS SHALL BE TAKEN TO PROTECT EXISTING
FACILITIES FROM DAMAGE DURING CONSTRUCTION.
E
GENERAL CONTRACTOR
RESPONSIBILITIES
1. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION LISTED
WITHIN THE CONSTRUCTION DOCUMENTS (PLANS, SPECIFICATIONS,
ETC.). SEQUENCE DEMOLITION WORK AS REQUIRED TO MAINTAIN
BUILDING INTEGRITY.
384384
DbB
DbB
DbB
UmB
UmB
DbB
DbB
DbB
INV IN 6" HDPE=378.7'
INV IN 6" HDPE=378.7'
INV IN 6" HDPE=378.6'
INV IN 6" HDPE=378.6'
INV IN 12" HDPE=382.7'
GRATE=391.76'
INV IN 6" HDPE=383.50' (FD)
INV IN 6" HDPE=386.10' (RD)
INV IN 6" HDPE=388.00' (RD)
INV OUT 12" HDPE=383.44' (FD)
INV IN 6" HPDE=382.8' (RD)
INV IN 6" HDPE=382.8 (FD)
C S-12
C S-12
C S-12
C S-12
C S-12
C S-12
C S-12
C S-12
C S-12
C S-12
CS-12 CS-12 CS-12 CS-12 CS-12 CS-12 CS-12 CS-12 CS-12 CS-12 CS-12
C S-12
C S-12
FILTER BAG INLET PROTECTION
TOPSOIL STOCKPILE
Bh SwD
PROPOSED GRADE (MAJOR)
12" COMPOST FILTER SOCK
PROPOSED GRADE (MINOR)
LIMIT OF DISTURBANCE
CS-12 CS-12
A
B
2 3
C
D
1 2 3
4 5 6
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
Entech Engineering - Printed: May. 11, 2026 H:\0004644.029\04-CAD\SheetFiles\New Work\ES-101.dwgLa st
E di te d by : m hi es te r
/1
1/
BI
D
D
IN
G C
AD
TO
W
N
SH
IP
O
F
SP
R
IN
G
TO
W N
SH
IP
O F
SP
R
IN
G
, B
ER
KS
C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
SI
TE
C
IV
IL
IM
PR
O
VE
M
EN
TS
A N
D B
U
IL
D
IN
G S
AF
ET
Y U
PG
R
AD
ES
ES-101
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
DRAWING NO.
4644.029
CAD
KJL
MAH
AS NOTED
/1
1/
GENERAL NOTES
SCALE:1 1" = 20'
EROSION AND SEDIMENTATION CONTROL PLAN
00 20' 40'
ER
O
SI
O
N A
N D
S
ED
IM
EN
TA
TI
O N
C O
N
TR
O L
PL
AN
SOIL TYPES
DbB DUFFIELD SILT LOAM, 3 TO 8 PERCENT SLOPES UmB URBAN LAND-DUFFIELD COMPLEX, 0 TO 8 PERCENT SLOPES
E&S LEGEND
1. REFER TO DRAWING G-001 FOR DRAWING INDEX, GENERAL PROJECT
NOTES, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-002 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
LIMIT OF DISTURBANCE
(0.42 ACRES)
TOPSOIL
STOCK PILE
CONCRETE
WASHOUT
TYPE-C FILTER BAG
INLET PROTECTION
12" COMPOST
FILTER SOCK (TYP)
ES-502
ALTERNATE No. 1
1-1/2" PAVEMENT MILL
AND OVERLAY
ES-502
ES-502
ES-502
EROSION CONTROL
BLANKET (NAG S-75)
TRENCH
RESTORATION (TYP.)
C-502
TRENCH
RESTORATION (TYP.)
C-502
TYPE-M FILTER BAG
INLET PROTECTION
ES-502
ES-502
TYPE-C FILTER BAG
INLET PROTECTION
ES-502
TYPE-C FILTER BAG
INLET PROTECTION
ES-502
TYPE-M FILTER BAG
INLET PROTECTION
ES-502
TYPE-M FILTER BAG
INLET PROTECTION
ES-502
TYPE-M FILTER BAG
INLET PROTECTION5
ES-502
TYPE-M FILTER BAG
INLET PROTECTION
ES-502
TYPE-M FILTER BAG
INLET PROTECTION
ES-502
TYPE-M FILTER BAG
INLET PROTECTION
ES-502
ER
O
SI
O
N A
N D
S
ED
IM
EN
TA
TI
O N
C O
N
TR
O L
N O
TE
S
A
B
2 3
C
D
1 2 3
4 5 6
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
Entech Engineering - Printed: May. 11, 2026 H:\0004644.029\04-CAD\SheetFiles\New Work\ES-501.dwgLa st
E di te d by : m hi es te r
/1
1/
BI
D
D
IN
G C
AD
TO
W
N
SH
IP
O
F
SP
R
IN
G
TO
W N
SH
IP
O F
SP
R
IN
G
, B
ER
KS
C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
SI
TE
C
IV
IL
IM
PR
O
VE
M
EN
TS
A N
D B
U
IL
D
IN
G S
AF
ET
Y U
PG
R
AD
ES
ES-501
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
DRAWING NO.
4644.029
CAD
KJL
MAH
AS NOTED
/1
1/
1. REFER TO DRAWING G-001 FOR DRAWING INDEX, GENERAL PROJECT
NOTES, LEGEND AND DRAWING CONVENTIONS.
GENERAL SHEET NOTESSTANDARD E&S PLAN NOTES
1. ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS WELL AS CUTS
AND FILLS SHALL BE DONE IN ACCORDANCE WITH THE APPROVED EROSION AND
SEDIMENT (E&S) A COPY OF THE APPROVED DRAWINGS (STAMPED, SIGNED AND DATED
BY THE BERKS COUNTY CONSERVATION DISTRICT) MUST BE AVAILABLE AT THE
PROJECT SITE AT ALL TIMES. THE CONSERVATION DISTRICT SHALL BE NOTIFIED OF
ANY CHANGES TO THE APPROVED PLAN PRIOR TO IMPLEMENTATION OF THOSE
CHANGES. THE DISTRICT MAY REQUIRE A WRITTEN SUBMITTAL OF THOSE CHANGES
FOR REVIEW AND APPROVAL AT ITS DISCRETION.
2. AREAS TO BE FILLED ARE TO BE CLEARED, GRUBBED, AND STRIPPED OF TOPSOIL TO
REMOVE TREES, VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL.
3. CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED TO THOSE AREAS
DESCRIBED IN EACH STAGE OF THE CONSTRUCTION SEQUENCE. GENERAL SITE
CLEARING, GRUBBING AND TOPSOIL STRIPPING MAY NOT COMMENCE IN ANY STAGE
OR PHASE OF THE PROJECT UNTIL THE E&S BEST MANAGEMENT PRACTICES (BMPS)
SPECIFIED BY THE CONSTRUCTION SEQUENCE FOR THAT STAGE OR PHASE HAVE
BEEN INSTALLED AND ARE FUNCTIONING AS DESCRIBED IN THIS E&S PLAN.
4. AT NO TIME SHALL CONSTRUCTION VEHICLES BE ALLOWED TO ENTER AREAS OUTSIDE
THE LIMIT OF DISTURBANCE BOUNDARIES SHOWN ON THE PLAN MAPS. THESE AREAS
MUST BE CLEARLY MARKED AND FENCED OFF BEFORE CLEARING AND GRUBBING
OPERATIONS BEGIN.
5. IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE
POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT POLLUTION, THE
OPERATOR SHALL IMPLEMENT APPROPRIATE BMPS TO MINIMIZE THE POTENTIAL FOR
EROSION AND SEDIMENT POLLUTION AND NOTIFY THE BERKS COUNTY CONSERVATION
DISTRICT AND/OR THE SOUTH-CENTRAL REGIONAL OFFICE OF DEP.
6. ALL PUMPING OF WATER FROM ANY WORK AREA SHALL BE DONE ACCORDING TO THE
PROCEDURE DESCRIBED IN THIS PLAN, OVER UNDISTURBED VEGETATED AREAS.
DISCHARGE POINTS SHOULD BE ESTABLISHED TO PROVIDE FOR MAXIMUM DISTANCE
TO ACTIVE WATERWAYS.
7. UNTIL THE SITE IS STABILIZED, ALL E&S BMPS MUST BE MAINTAINED PROPERLY.
MAINTENANCE SHALL INCLUDE INSPECTIONS OF ALL E&S BMPS AFTER EACH RUNOFF
EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND REMEDIAL MAINTENANCE
WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT, REGRADING, RESEEDING,
REMULCHING AND RENETTING MUST BE PERFORMED IMMEDIATELY. IF E&S BMPS FAIL
TO PERFORM AS EXPECTED, REPLACEMENT BMPS, OR MODIFICATIONS OF THOSE
INSTALLED WILL BE REQUIRED.
8. A LOG SHOWING DATES THAT E&S BMPS WERE INSPECTED AS WELL AS ANY
DEFICIENCIES FOUND AND THE DATE THEY WERE CORRECTED SHALL BE MAINTAINED
ON THE SITE AND BE MADE AVAILABLE TO REGULATORY AGENCY OFFICIALS AT THE
TIME OF INSPECTION.
9. SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL BE RETURNED
TO THE CONSTRUCTION SITE BY THE END OF EACH WORK DAY AND DISPOSED IN THE
MANNER DESCRIBED IN THIS PLAN. IN NO CASE SHALL THE SEDIMENT BE WASHED,
SHOVELED, OR SWEPT INTO ANY ROADSIDE DITCH, STORM SEWER, OR SURFACE
WATER.
10. ALL SEDIMENT REMOVED FROM BMPS SHALL BE DISPOSED OF IN THE MANNER
DESCRIBED ON THE PLAN DRAWINGS.
11. ALL EXCAVATION FOR UTILITY LINE INSTALLATION SHALL BE LIMITED TO THE AMOUNT
THAT CAN BE EXCAVATED, INSTALLED, BACKFILLED AND STABILIZED WITHIN ONE
WORKING DAY. ALL EXCAVATED MATERIAL SHALL BE DEPOSITED ON THE UPSLOPE
SIDE OF THE TRENCH.
12. CONCRETE WASH WATER SHALL BE HANDLED IN THE MANNER DESCRIBED ON THE
PLAN DRAWINGS. IN NO CASE SHALL IT BE ALLOWED TO ENTER ANY SURFACE WATERS
OR GROUNDWATER SYSTEMS.
13. SEEPS OR SPRINGS ENCOUNTERED DURING CONSTRUCTION SHALL BE HANDLED IN
ACCORDANCE WITH THE STANDARD AND SPECIFICATION FOR SUBSURFACE DRAIN OR
OTHER APPROVED METHOD.
14. FAILURE TO CORRECTLY INSTALL E&S BMPS, FAILURE TO PREVENT SEDIMENT-LADEN
RUNOFF FROM LEAVING THE CONSTRUCTION SITE, OR FAILURE TO TAKE IMMEDIATE
CORRECTIVE ACTION TO RESOLVE FAILURE OF E&S BMPS MAY RESULT IN
ADMINISTRATIVE, CIVIL, AND/OR CRIMINAL PENALTIES BEING INSTITUTED BY THE
PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION AS DEFINED IN
SECTION 602 OF THE PENNSYLVANIA CLEAN STREAMS LAW. THE CLEAN STREAMS LAW
PROVIDES FOR UP TO $10,000 PER DAY IN CIVIL PENALTIES, UP TO $10,000 IN SUMMARY
CRIMINAL PENALTIES, AND UP TO $25,000 IN MISDEMEANOR CRIMINAL PENALTIES FOR
EACH VIOLATION.
CONSTRUCTION SEQUENCE
1. PRIOR TO CONSTRUCTION, THE PROPOSED LIMIT OF DISTURBANCE (LOD) SHALL BE
DELINEATED AND STAKED IN THE FIELD.
2. THE EXISTING STREETS WILL BE UTILIZED FOR ACCESS TO THE WORK AREAS.
3. INSTALL PERIMETER EROSION AND SEDIMENT CONTROL BMPS, INCLUDING SILT SOCKS
AND INLET FILTER BAGS, IN ACCORDANCE WITH THE APPROVED PLANS.
4. INSTALL A DESIGNATED CONCRETE WASHOUT AREA IN ACCORDANCE WITH THE
APPROVED EROSION AND SEDIMENT CONTROL PLAN PRIOR TO ANY CONCRETE WORK.
5. STORAGE AND LAYDOWN AREAS WILL BE LOCATED IN EXISTING PAVED OR GRAVEL
AREAS. IF ADDITIONAL STORAGE AREAS ARE REQUIRED, OBTAIN APPROVAL FROM THE
APPROPRIATE AUTHORITY PRIOR TO USE.
6. PERFORM DEMOLITION AND REMOVAL OPERATIONS IN PROPOSED WORK AREAS,
INCLUDING SAWCUTTING/REMOVAL OF EXISTING PAVEMENT AND SIDEWALK,
TRENCHING AS REQUIRED TO ACCESS/REMOVE EXISTING FOUNDATION DRAINS AND
ROOF DRAINS, AND CUTTING AND CAPPING ALL LINES CALLED OUT TO BE CUT AND
CAPPED IN PLACE.
7. EXCAVATE, BACKFILL, AND COMPACT FOR THE INSTALLATION OF NEW PIPING,
INCLUDING TRENCHING FOR NEW FOUNDATION DRAINS AND ROOF DRAINS.
8. INSTALL NEW FOUNDATION DRAINS AND ROOF DRAINS AND CONNECT/TIE-IN TO INLETS
AND/OR OTHER APPROVED STORM SYSTEM CONNECTION POINTS AS INDICATED ON
THE DRAWINGS.
9. RESTORE SUBGRADES AND COMPLETE FINAL GRADING IN PROPOSED WORK AREAS IN
ACCORDANCE WITH THE DRAWINGS.
10. PLACE FINAL PAVEMENT AND CONCRETE SIDEWALK IN ACCORDANCE WITH THE
APPROVED GRADING AND PROJECT DRAWINGS.
11. TRENCHING WORK FOR NEW PIPES SHALL BE LIMITED TO THE AMOUNT THAT CAN BE
EXCAVATED, INSTALLED, BACKFILLED, AND STABILIZED WITHIN ONE WORKDAY.
TRENCHING SHALL CONFORM TO THE FOLLOWING BMP PROCEDURES:
· STOCKPILE EXCAVATED SOIL IN A CONTROLLED LOCATION TO PREVENT SEDIMENT
TRANSPORT.
· BACKFILL WITH SELECT MATERIAL WHERE SPECIFIED.
· DEWATER EXCAVATIONS, IF NECESSARY, TO A FILTER BAG OR APPROVED
DEWATERING DEVICE IN A STABLE VEGETATED AREA AND PROVIDE ADDITIONAL
CONTROLS AROUND THE DISCHARGE AS REQUIRED.
11. ON STEEP SLOPES, INSTALL EROSION CONTROL BLANKETS ON AREAS WITH SLOPES
3H:1V OR STEEPER, OR AS SPECIFIED.
12. IF CONSTRUCTION IS TERMINATED OR SUSPENDED PRIOR TO COMPLETION, ALL
EXPOSED SOIL AREAS SHALL BE SEEDED WITH TEMPORARY SEEDING AND MULCHED
IMMEDIATELY.
13. THE CONTRACTOR SHALL INSPECT EROSION AND SEDIMENT CONTROL BMPS WEEKLY
AND AFTER EACH RAINFALL EVENT. POST-STORM INSPECTIONS SHALL BE CONDUCTED
WITHIN 24 HOURS AFTER EACH MEASURABLE STORM EVENT (0.25 INCH OR GREATER)
OR THE OCCURRENCE OF SNOWMELT SUFFICIENT TO CAUSE A DISCHARGE.
14. THE CONTRACTOR SHALL REPAIR ANY DAMAGED BMPS IMMEDIATELY. REMOVED
SEDIMENT SHALL BE PLACED IN DESIGNATED UPLAND AREAS AND STABILIZED.
15. MAINTAIN ALL EROSION AND SEDIMENT CONTROL BMPS IN EFFECTIVE WORKING
ORDER UNTIL ALL DISTURBED AREAS ARE PERMANENTLY STABILIZED.
16. STABILIZATION SHALL BE DEFINED AS:
· VEGETATED AREAS: 70% UNIFORM PERENNIAL COVER.
· PAVED AREAS: APPLICATION OF THE BASE COURSE LAYER (OR FINAL SURFACE
WHERE APPLICABLE).
17. REMOVED SEDIMENT SHALL BE INCORPORATED INTO FINAL GRADING OPERATIONS OR
DISPOSED OF OFF-SITE IN ACCORDANCE WITH APPLICABLE SOLID WASTE
MANAGEMENT REGULATIONS.
18. AFTER FINAL STABILIZATION HAS BEEN ACHIEVED, REMOVE TEMPORARY BMPS.
IMMEDIATELY STABILIZE ANY AREAS DISTURBED DURING BMP REMOVAL.
NOTE: A COPY OF THE SEDIMENT AND EROSION CONTROL PLAN MUST BE
AVAILABLE AT THE PROJECT SITE DURING CONSTRUCTION UNTIL
STABILIZATION IS ACHIEVED.
MATERIAL NOTES
1. ALL BUILDING MATERIALS AND WASTES MUST BE REMOVED FROM THE SITE AND
RECYCLED OR DISPOSED OF IN ACCORDANCE WITH THE DEPARTMENT’S SOLID WASTE
MANAGEMENT REGULATIONS AT 25 PA. CODE CHAPTER 260, §§260.1 ET SEQ., 271.1,
AND 287.1 ET. NO BUILDING MATERIALS OR WASTES OR UNUSED BUILDING MATERIALS
SHALL BE BURNED, BURIED, DUMPED, OR DISCHARGED AT THE SITE.
2. ALL OFF-SITE WASTE AND BORROW AREAS MUST HAVE AN E&S PLAN APPROVED BY A
COUNTY CONSERVATION DISTRICT OR DEP FULLY IMPLEMENTED PRIOR TO BEING
ACTIVATED.
3. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL BROUGHT ON
SITE IS CLEAN FILL. FORM FP-001 MUST BE RETAINED BY THE PROPERTY OWNER FOR
ANY FILL MATERIAL AFFECTED BY A SPILL OR RELEASE OF A REGULATED SUBSTANCE
BUT QUALIFYING AS CLEAN FILL DUE TO ANALYTICAL TESTING. ALL FILLS SHALL BE
COMPACTED AS REQUIRED TO REDUCE EROSION, SLIPPAGE, SETTLEMENT,
SUBSIDENCE OR OTHER RELATED PROBLEMS. FILL INTENDED TO SUPPORT BUILDINGS,
STRUCTURES AND CONDUITS, ETC. SHALL BE COMPACTED IN ACCORDANCE WITH
LOCAL REQUIREMENTS OR CODES.
4. ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO EXCEED 9
INCHES IN THICKNESS.
5. FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS, SOD, OR
OTHER FOREIGN OR OBJECTIONABLE MATERIALS THAT WOULD INTERFERE WITH OR
PREVENT CONSTRUCTION OF SATISFACTORY FILLS.
6. FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY COMPRESSIBLE MATERIALS SHALL
NOT BE INCORPORATED INTO FILLS.
7. FILL SHALL NOT BE PLACED ON SATURATED OR FROZEN SURFACES.
STABILIZATION NOTES
1. TOPSOIL REQUIRED FOR THE ESTABLISHMENT OF VEGETATION SHALL BE STOCKPILED
AT THE LOCATION(S) SHOWN ON THE PLAN MAPS(S) IN THE AMOUNT NECESSARY TO
COMPLETE THE FINISH GRADING OF ALL EXPOSED AREAS THAT ARE TO BE STABILIZED
BY VEGETATION. EACH STOCKPILE SHALL BE PROTECTED IN THE MANNER SHOWN ON
THE PLAN DRAWINGS. STOCKPILE HEIGHTS SHALL NOT EXCEED 35 FEET. STOCKPILE
SLOPES SHALL BE 2H:1V OR FLATTER.
2. AREAS WHICH ARE TO BE TOPSOILED SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 3
TO 5 INCHES, OR 6 TO 12 INCHES ON COMPACTED SOILS, PRIOR TO PLACEMENT OF
TOPSOIL. AREAS TO BE VEGETATED SHALL HAVE A MINIMUM 4 INCHES OF TOPSOIL IN
PLACE PRIOR TO SEEDING AND MULCHING. FILL OUTSLOPES SHALL HAVE A MINIMUM
OF 2 INCHES OF TOPSOIL.
3. UPON TEMPORARY CESSATION OF AN EARTH DISTURBANCE, THE SITE SHALL BE
IMMEDIATELY SEEDED, MULCHED OR OTHERWISE PROTECTED FROM ACCELERATED
EROSION AND SEDIMENTATION PENDING FUTURE EARTH DISTURBANCE ACTIVITIES.”
4. STRAW MULCH MUST BE APPLIED AT RATES OF AT LEAST 3.0 TONS PER ACRE. STRAW
MULCH SHOULD BE ANCHORED IMMEDIATELY AFTER APPLICATION TO PREVENT BEING
WINDBLOWN.
5. ALL GRADED AREAS SHALL BE PERMANENTLY STABILIZED IMMEDIATELY UPON
REACHING FINISHED GRADE. CUT SLOPES IN COMPETENT BEDROCK AND ROCK FILLS
NEED NOT BE VEGETATED.
6. EROSION CONTROL BLANKETING SHALL BE INSTALLED ON ALL SLOPES 3H:1V OR
STEEPER, WITHIN 50 FEET OF A SURFACE WATER AND ON ALL OTHER DISTURBED
AREAS ACCORDING TO THE STANDARDS OF THIS PLAN.
7. IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE IN ANY AREA OR
SUBAREA OF THE PROJECT, THE OPERATOR SHALL STABILIZE ALL DISTURBED AREAS.
DURING NON-GERMINATING MONTHS, MULCH OR PROTECTIVE BLANKETING SHALL BE
APPLIED AS DESCRIBED IN THE PLAN. AREAS NOT AT FINISHED GRADE, WHICH WILL BE
REACTIVATED WITHIN 1 YEAR, MAY BE STABILIZED IN ACCORDANCE WITH THE
TEMPORARY STABILIZATION SPECIFICATIONS. THOSE AREAS WHICH WILL NOT BE
REACTIVATED WITHIN 1 YEAR SHALL BE STABILIZED IN ACCORDANCE WITH THE
PERMANENT STABILIZATION SPECIFICATIONS.
8. PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70%
VEGETATIVE COVER OR OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY
SUFFICIENT TO RESIST ACCELERATED EROSION. CUT AND FILL SLOPES SHALL BE
CAPABLE OF RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.
9. E&S BMPS SHALL REMAIN FUNCTIONAL AS SUCH UNTIL ALL AREAS TRIBUTARY TO
THEM ARE PERMANENTLY STABILIZED OR UNTIL THEY ARE REPLACED BY ANOTHER
BMP APPROVED BY THE BERKS COUNTY CONSERVATION DISTRICT OR DEP.
RECOMMENDED MULCHING SPECIFICATIONS
1. MULCHING SHALL BE PROVIDED AS REQUIRED IN AREAS DIFFICULT TO VEGETATE, AND
DURING OFF-SEASON OPERATIONS. MULCHING METHODS AND MATERIALS SHALL
CONFORM TO THE FOLLOWING:
a. MULCH MATERIALS SHALL BE UNROTTED SALT HAY, HAY OR SMALL GRAIN STRAW
APPLIED AT THE RATE OF 3 TONS PER ACRE. MULCH BLOWER SHALL NOT GRIND
OR CHOP THE MATERIAL. WOODCHIPS, FREE OF INSECTS AND DISEASE ARE
PERMITTED AT A RATE OF 4-6 TONS PER ACRE.
b. MULCH SHALL BE SPREAD UNIFORMLY BY HAND OR MECHANICALLY SO THAT
APPROXIMATELY 85% TO 95% OF THE SOIL SURFACE WILL BE COVERED. MULCH
ANCHORING SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PLACEMENT TO
MINIMIZE LOSS BY WIND OR WATER. THIS MAY BE DONE BY ONE OF THE
FOLLOWING METHODS, DEPENDING UPON THE SIZE OF THE SLOPE.
i. PEG AND TWINE – DRIVE 8” TO 10” PEGS TO WITHIN 2” TO 3” OF THE SOIL
SURFACE EVERY 4’ IN ALL DIRECTIONS. TAKES MAY BE DRIVEN BEFORE OR
AFTER APPLYING MULCH. SECURE THE MULCH TO THE SOIL SURFACE BY
STRETCHING TWINE BETWEEN PEGS IN A CRISSCROSS OR SQUARE
PATTERN, AND SECURE THE TWIN AROUND EACH PEG WITH TWO OR MORE
ROUND
ii. MULCH NETTING – STAPLE PAPER, JUTE, COTTON OR PLASTIC NETTINGS TO
THE SOIL SURFACE. USE DEGRADABLE NETTING IN AREAS TO BE MOWED.
iii. MULCH MATERIALS AND BINDERS SHALL BE ROLLED IN PLACE BY TRACKED
VEHICLE OR OTHER SUITABLE EQUIPMENT.
c. APPLICATIONS SHOULD BE HEAVIER AT EDGES WHERE WIND CATCHES THE
MULCH. IN VALLEYS AND AT CRESTS OF BANKS. REMAINDER OF AREA SHOULD BE
UNIFORM IN APPEARANCE.
d. WOOD-FIBER OR PAPER-FIBER MULCH AT THE RATE OF 1,500 LBS PER ACRE, OR
PER MANUFACTURER RECOMMENDATION, MAY BE APPLIED BY A HYDROSEEDER.
USE IS LIMITED TO FLATTER SLOPES AND DURING OPTIMUM SEEDING PERIODS IN
SPRING AND OTHER:
f. WHERE EXCESSIVE SOIL EROSION, TRACKING OR FLOWING OF SEDIMENT IS
EVIDENT OR ANTICIPATED, A MINIMUM OF 4” OF CRUSHED STONE SHALL BE
PLACED WITHIN THE AFFECTED AREA AND MAINTAINED UNTIL PERMANENT
STABILIZATION IS PROVIDED. ADDITIONAL STONE SHALL BE PLACED AS REQUIRED
UNTIL STABILIZATION IS ACHIEVED. CRUSHED STONE SHALL CONFORM TO AASTO
DESIGNATION M43. SIZE NO. 2 (2-1/2” TO 1-1/2”).
CHANNEL NOTES (APPLICABLE TO E&S PLANS WITH PROPOSED CHANNELS)
1. ALL CHANNELS SHALL BE KEPT FREE OF OBSTRUCTIONS INCLUDING BUT NOT LIMITED
TO FILL, ROCKS, LEAVES, WOODY DEBRIS, ACCUMULATED SEDIMENT, EXCESS
VEGETATION, AND CONSTRUCTION MATERIAL/WASTES.
2. UNDERGROUND UTILITIES CUTTING THROUGH ANY ACTIVE CHANNEL SHALL BE
IMMEDIATELY BACKFILLED AND THE CHANNEL RESTORED TO ITS ORIGINAL
CROSS-SECTION AND PROTECTIVE ANY BASE FLOW WITHIN THE CHANNEL SHALL BE
CONVEYED PAST THE WORK AREA IN THE MANNER DESCRIBED IN THIS PLAN UNTIL
SUCH RESTORATION IS COMPLETE.
3. CHANNELS HAVING RIPRAP, RENO MATTRESS, OR GABION LININGS MUST BE
SUFFICIENTLY OVER-EXCAVATED SO THAT THE DESIGN DIMENSIONS WILL BE
PROVIDED AFTER PLACEMENT OF THE PROTECTIVE LINING.
RECYCLING AND DISPOSAL METHODS
CONSTRUCTION MATERIALS AND OTHER CONSTRUCTION SITE WASTES MUST BE
PROPERLY MANAGED AND DISPOSED OF TO REDUCE POTENTIAL FOR POLLUTION TO
SURFACE AND GROUND WATERS AS PER 25 PA. CODE § 102.4(B)(5)(XI). PROPER TRASH
DISPOSAL, RECYCLING OF MATERIALS, PROPER MATERIALS HANDLING, AND SPILL
PREVENTION AND CLEAN-UP REDUCE THE POTENTIAL FOR CONSTRUCTION SITE WASTES
TO BE MOBILIZED BY STORMWATER RUNOFF AND CONVEYED TO SURFACE WATERS.
· COLLECTED SEDIMENT WILL BE PLACED ON FILL SLOPES AND GRADED, SEEDED AND
MULCHED AS NEEDED TO ATTAIN STABILIZATION.
· THE CONTRACTOR SHALL REMOVE FROM THE SITES, RECYCLE OR DISPOSE OF ALL
MATERIALS AND WASTES IN ACCORDANCE WITH THE DEPARTMENT'S SOLID WASTE
MANAGEMENT REGULATIONS AT 25 PA CODE 260.1 ET SEQ., 271.1 E. SEQ. AND 287.1 ET
SEQ.
· ANTICIPATED CONSTRUCTION WASTES FOR THIS PROJECT MAY INCLUDE PAVEMENT,
SOIL, CONCRETE AND SOME EXISTING PIPE.
GROUND COVER
AFTER THE EARTH DISTURBANCE ACTIVITY IS COMPLETED, THE DISTURBED AREA MUST BE
REVEGETATED. THE VEGETATIVE COVER MUST BE A UNIFORM 70% PERENNIAL VEGETATIVE
COVER, WITH A DENSITY CAPABLE OF RESISTING ACCELERATED EROSION AND
SEDIMENTATION. ANOTHER OPTION IS TO USE AN ACCEPTABLE BMP, WHICH PERMANENTLY
MINIMIZES ACCELERATED EROSION AND SEDIMENTATION.
TEMPORARY SEEDING
TEMPORARY SEEDING WILL BE PERFORMED DURING THE GERMINATION SEASON (APRIL TO
OCTOBER) FOR THE ESTABLISHMENT OF GRASS SEED ON DISTURBED AREAS BEFORE THE
START OF THE DORMANT SEASON. DURING THE NON-GERMINATION SEASON, MULCH SHALL
BE APPLIED TO THE DISTURBED SURFACES AND THE SEED MIXTURE WILL BE ADDED AT THE
START OF THE GERMINATION PERIOD.
· ALL GRASS AREAS DISTURBED BY THE WORK OF THIS PROJECT SHALL BE
SEEDED AS FOLLOWS:
O APPLY AGRICULTURAL LIME AND FERTILIZER AS FOLLOWS FOR TEMPORARY
SEEDING:
¨ AGRICULTURAL LIME - 40 POUNDS PER 1,000 SQUARE FEET
¨ FERTILIZER - 12.5 POUNDS PER 1,000 SQUARE FEET
O FERTILIZER SHALL BE A COMMERCIAL TYPE 10-10-10.
O TEMPORARY SEED MIXTURE ANNUAL RYEGRASS -- 1 POUND PER 1,000
SQUARE FEET.
· ALL TEMPORARY SEEDING SHALL BE MULCHED. TEMPORARY SEEDING SHALL BE
WATERED AS REQUIRED TO DEVELOP COVER. NON-POTABLE UTILITY WATER
SHALL BE PROVIDED BY THE CONTRACTOR.
· MULCH SHALL BE STRAW, SHALL BE CLEAN AND FREE FROM NOXIOUS WEEDS,
AND SHALL BE APPLIED AT THE RATE OF 140 POUNDS PER 1,000 SQUARE FEET
(3.0 TONS PER ACRE).
O APPLICATION OF MULCH SHALL BE USED IN CONJUNCTION WITH CRIMPING, A
TACKIFIER OR A SIMILAR METHOD IN ORDER TO PREVENT MULCH FROM
BEING WINDBLOWN.
PERMANENT SEEDING
PERMANENT SEEDING SHALL TAKE PLACE IN ALL DISTURBED AREAS AS FOLLOWS:
· UPON COMPLETION OF EARTH DISTURBANCE ACTIVITIES, THE SITE SHALL BE
IMMEDIATELY STABILIZED.
· THE FOLLOWING SHALL BE SPREAD AND WORKED INTO THE TOPSOIL TO A DEPTH
OF 2 TO 4 INCHES.
O AGRICULTURAL LIME - 240 POUNDS PER 1,000 SQUARE FEET
O FERTILIZER - 25 POUNDS PER 1,000 SQUARE FEET
· THE FERTILIZER SHALL BE A COMMERCIAL TYPE 10-20-20.
· NOTE - IF AGRICULTURAL LIME AND FERTILIZER HAVE BEEN APPLIED PREVIOUSLY
TO THE GROUND WHERE THE PERMANENT SEED IS TO BE APPLIED, THE LIME AND
FERTILIZER RATES SHALL BE REDUCED BY THE AMOUNT BY WHAT HAS BEEN
APPLIED PREVIOUSLY.
· PERMANENT SEED MIXTURE: THE FOLLOWING SEED MIXTURES SHALL BE
APPLIED AS FOLLOWS:
O APPLY MULCH TO ALL PERMANENTLY SEEDED AREAS.
O MATERIALS: STRAW, AIR-DRIED AND FREE FROM UNDESIRABLE SEEDS AND COURSE
MATERIALS. APPLICATION: 140 POUNDS PER 1,000 SQUARE FEET.
· APPLICATION OF MULCH SHALL BE USED IN CONJUNCTION WITH CRIMPING, A
TACKIFIER OR A SIMILAR METHOD IN ORDER TO PREVENT MULCH FROM BEING
WINDBLOWN.
· EROSION CONTROL BLANKETS SHALL BE USED ON SLOPES 3:1 (H:V) OR GREATER.
B
2 3
C
D
1 2 3
4 5 6
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
Entech Engineering - Printed: May. 11, 2026 H:\0004644.029\04-CAD\SheetFiles\New Work\ES-502.dwgLa st
E di te d by : m hi es te r
/1
1/
BI
D
D
IN
G C
AD
TO
W
N
SH
IP
O
F
SP
R
IN
G
TO
W N
SH
IP
O F
SP
R
IN
G
, B
ER
KS
C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
SI
TE
C
IV
IL
IM
PR
O
VE
M
EN
TS
A N
D B
U
IL
D
IN
G S
AF
ET
Y U
PG
R
AD
ES
ES-502
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
DRAWING NO.
4644.029
CAD
KJL
MAH
AS NOTED
/1
1/
C
O N
TR
O
L D
ET
AI
LS
ER
O
SI
O N
A N
D S
ED
IM
EN
TA
TI
O
N
NOTES:
1. COMPOST FILTER SOCK SHALL BE PLACED AT EXISTING LEVEL GRADE. BOTH ENDS OF
THE SOCK SHALL BE EXTENDED AT LEAST 8 FEET UPSLOPE AT 45 DEGREES TO THE
MAIN SOCK ALIGNMENT. MAXIMUM SLOPE LENGTH ABOVE ANY 12" AND 18" DIAMETER
SOCK SHALL NOT EXCEED THE SLOPE LENGTH THAT IS ALLOWED FOR 18" AND 30"
REINFORCED SILT FENCE. MAXIMUM SLOPE LENGTH FOR 24" DIAMETER SOCK SHALL
NOT EXCEED THAT FOR SUPER SILT FENCE.
2. TRAFFIC SHALL NOT BE PERMITTED TO CROSS FILTER SOCKS..
3. ACCUMULATED SEDIMENT SHALL BE REMOVED WHEN IT REACHES HALF THE ABOVE
GROUND HEIGHT OF THE SOCKS AND DISPOSED IN THE MANNER DESCRIBED
ELSEWHERE IN THE PLAN.
4. SOCKS SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT. DAMAGED
SOCKS SHALL BE REPAIRED ACCORDING TO MANUFACTURER'S SPECIFICATIONS OR
REPLACED WITHIN 24 HOURS OF INSPECTION.
5. BIODEGRADABLE FILTER SOCK SHALL BE REPLACED AFTER 6 MONTHS;
PHOTODEGRADABLE SOCKS AFTER ONE YEAR. POLYPROPYLENE SOCKS SHALL BE
REPLACED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
6. UPON STABILIZATION OF THE AREA TRIBUTARY TO THE SOCK, STAKES SHALL BE
REMOVED. THE SOCK MAY BE LEFT IN PLACE AND VEGETATED OR REMOVED. IN THE
LATTER CASE, THE MESH SHALL BE CUT OPEN AND THE MULCH SPREAD AS A SOIL
SUPPLEMENT.
' M
IN
SCALE:2 NONE
COMPOST FILTER SOCK
STANDARD CONSTRUCTION DETAIL #4-1
FL
O
W FLO
W
DISTURBED
AREA
UNDISTURBED AREA
2" x 2" WOODEN STAKES
PLACED 10' O.C.
2" x 2" WOODEN STAKES
PLACED 10' O.C.
COMPOST FILTER SOCK
UNDISTURBED AREA
BLOWN PLACED
FILTER MEDIA
DISTURBED AREA
PLAN VIEW
SECTION VIEW
NOTE:
STOCKPILE HEIGHTS MUST NOT EXCEED 35 FEET.
STOCKPILE SLOPES MUST BE 3:1 OR FLATTER.
SCALE:3 NONE
TYPICAL STOCKPILE DETAIL
STOCKPILE
MATERIAL
FILTER FABRIC OR
EQUIVALENT COMPOST
FILTER SOCK
FILTER FABRIC OR
EQUIVALENT COMPOST
FILTER SOCK
PLAN VIEW (TYPICAL)
STOCKPILE
MATERIAL
SLOPE
SLOPE
2 MIN. (TYP.)
INSTALLATION DETAIL
ISOMETRIC VIEW
PLAN VIEW
SCALE:5 NONE
FILTER BAG INLET PROTECTION - TYPE M INLET
STANDARD CONSTRUCTION DETAIL #4-16
2'
4'
3'
WIDTH LENGTH
FLOW
ELEVATION VIEW FLOW
NOTES:
1. MAXIMUM DRAINAGE AREA= 1/2 ACRE
2. INLET PROTECTION SHALL NOT BE REQUIRED FOR INLET TRIBUTARY TO SEDIMENT BASIN OR TRAP.
BERMS SHALL BE REQUIRED FOR ALL INSTALLATIONS.
3. ROLLED EARTHEN BERM SHALL BE PROVIDED AND MAINTAINED IMMEDIATELY DOWN GRADIENT OF THE PROTECTED INLET UNTIL ROADWAY IS STONED. ROAD SUB-BASE BERM SHALL BE MAINTAINED UNTIL ROADWAY IS PAVED. SIX INCH MINIMUM HEIGHT ASPHALT BERM SHALL BE MAINTAINED UNTIL
ROADWAY SURFACE RECEIVES FINAL COAT.
4. AT A MINIMUM, THE FABRIC SHALL HAVE A MINIMUM GRAB TENSILE STRENGTH OF 120 LBS, A MINIMUM BURST STRENGTH OF 200 PSI, AND A MINIMUM TRAPEZOIDAL TEAR STRENGTH OF 50 LBS. FILTER
BAGS SHALL BE CAPABLE OF TRAPPING ALL PARTICLES NOT PASSING A NO. 40 SIEVE.
5. INLET FILTER BAGS SHALL BE INSPECTED ON A WEEKLY BASIS AND AFTER EACH RUNOFF EVENT.
BAGS SHALL BE EMPTIED AND RINSED OR REPLACED WHEN HALF FULL OR WHEN FLOW CAPACITY
HAS BEEN REDUCED SO AS TO CAUSE FLOODING OR BYPASSING OF THE INLET. DAMAGED OR
CLOGGED BAGS SHALL BE REPLACED. A SUPPLY SHALL BE MAINTAINED ON SITE FOR REPLACEMENT OF BAGS. ALL NEEDED REPAIRS SHALL BE INITIATED IMMEDIATELY AFTER THE INSPECTION. DISPOSE
OF ACCUMULATED SEDIMENT AS WELL AS ALL USE BAGS ACCORDING TO THE PLAN NOTES
6. DO NOT USE ON MAJOR PAVED ROADWAYS WHERE PONDING MAY CAUSE TRAFFIC HAZARDS.
EXPANSION RESTRAINT
(1/4" NYLON ROPE)
2" x 2" x 3/4"
RUBBER BLOCK
1" REBAR FOR
BAG REMOVAL
FROM INLET
REMOVAL
FROM INLET
6" MIN. HEIGHT
BERM
3:1
EARTHEN BERM TO BE STABILIZED
W/ TEMPORARY OR PERMANENT
VEGETATION
2 MIN. : 1STORM
INLET
EXTEND BERM OVER CURB
IF RUN-OFF IS BYPASSING
INLET ON LANDWARD SIDE
SCALE:1 NONE
PUMPED WATER FILTER BAG
STANDARD CONSTRUCTION DETAIL #3-16
LOW VOLUME FILTER BAGS SHALL BE MADE FROM NON-WOVEN GEOTEXTILE MATERIAL
SEWN WITH HIGH STRENGTH, DOUBLE STICHED "J" TYPE SEAMS. THEY SHALL BE
CAPABLE OF TRAPPING PARTICLES LARGER THAN 151 MICRONS. HIGH VOLUME FILTER
BAGS SHALL BE MADE FROM WOVEN GEOTEXTILES THAT MEET THE FOLLOWING
STANDARDS:
PROPERTY TEST METHOD MINIMUM STANDARD
AVG. WIDE WIDTH STRENGTH ASTM D-4884 60 lb/in
GRAB TENSILE ASTM D-4632 205 lb
PUNCTURE ASTM D-4833 110 lb
MULLEN BURST ASTM D-3786 350 psi
UV RESISTENCE ASTM D-4355 70%
AOS % RETAINED ASTM D-4751 80 Sieve
NOTES:
1. A SUITABLE MEANS OF ACCESSING THE BAG WITH MACHINERY REQUIRED FOR DISPOSAL PURPOSES SHALL BE PROVIDED. FILTER BAGS SHALL BE REPLACED WHEN THEY BECOME 1/2 FULL OF SEDIMENT.
SPARE BAGS SHALL BE KEPT AVAILABLE FOR REPLACEMENT OF THOSE THAT HAVE FAILED OR ARE FILLED. BAGS SHALL BE PLACED ON STRAPS TO FACILITATE REMOVAL UNLESS BAGS COME WITH
LIFTING STRAPS ALREADY ATTACHED.
2. BAGS SHALL BE LOCATED IN WELL-VEGETATED (GRASSY) AREA, AND DISCHARGE ONTO STABLE, EROSION RESISTANT AREAS. WHERE THIS IS NOT POSSIBLE, A GEOTEXTILE UNDERLAYMENT AND FLOW
PATH SHALL BE PROVIDED. BAGS MAY BE PLACED ON FILTER STONE TO INCREASE DISCHARGE
CAPACITY. BAGS SHALL NOT BE PLACED ON SLOPES GREATER THAN 5%. FOR SLOPES EXCEEDING 5%, CLEAN ROCK OR OTHER NON-ERODIBLE AND NON-POLLUTING MATERIAL MAY BE PLACED UNDER THE
BAG TO REDUCE SLOPE STEEPNESS.
3. NO DOWNSLOPE SEDIMENT BARRIER IS REQUIRED FOR MOST INSTALLATIONS. COMPOST BERM OR COMPOST FILTER SOCK SHALL BE INSTALLED BELOW BAGS LOCATED IN HQ OR EV WATERSHEDS, WITHIN 50 FT. OF ANY RECEIVING SURFACE WATER OR WHERE GRASSY AREA IS NOT AVAILABLE.
4. THE PUMP DISCHARGE HOSE SHALL BE INSERTED INTO BAGS IN THE MANNER SPECIFIED BY THE
MANUFACTURER AND SECURELY CLAMPED. A PIECE OF PVC PIPE IS RECOMMENDED FOR THIS
PURPOSE.
5. THE PUMPING RATE SHALL BE NO GREATER THAN 750 GPM OR 1/2 THE MAXIMUM SPECIFIED BY THE
MANUFACTURER, WHICHEVER IS LESS. PUMP INTAKES SHALL BE FLOATING AND SCREENED.
6. FILTER BAGS SHALL BE INSPECTED DAILY. IF ANY PROBLEM IS DETECTED, PUMPING SHALL CEASE
IMMEDIATELY AND NOT RESUME UNTIL THE PROBLEM IS CORRECTED.
FILTER BAG
FILTER BAG
WELL VEGETATED, GRASSY AREA
PUMP
INTAKE HOSE
CLAMPS
DISCHARGE HOSE
HEAVY DUTY LIFTING STRAPS
(RECOMMENDED)
INTAKE HOSE
CLAMPS
DISCHARGE HOSE
PUMP
WELL VEGETATED, GRASSY AREA
ELEVATION VIEW
PLAN VIEW
COMPOST FILTER
SOCK RING REQUIRED
FOR THIS INSTALLATION
NOTE:
FOR SPECIAL PROTECTION WATERSHED, COMPOST BERM OR COMPOST FILTER SOCK SHALL
BE INSTALLED BELOW BAGS LOCATED IN HQ OR EV WATERSHEDS, WITHIN 50 FT. OF ANY
RECEIVING SURFACE WATER OR WHERE GRASSY AREA IS NOT AVAILABLE.
SCALE:4 NONE
CONCRETE WASHOUT DETAIL
SCALE:7 NONE
EROSION CONTROL BLANKET INSTALLATION
STANDARD CONSTRUCTION DETAIL #11-1
BLANKET EDGES
STAPLED AND
OVERLAPPED
(4 IN. MIN.)
INSTALL BEGINNING OF ROLL IN 6 IN.
x 6 IN. ANCHOR TRENCH, STAPLE, BACKFILL AND COMPACT SOIL
STARTING AT TOP OF SLOPE,
ROLL BLANKETS IN DIRECTION
OF WATER FLOW
REFER TO MANUF.
RECOMMENDED STAPLING
PATTERN FOR STEEPNESS AND
LENGTH OF SLOPE BEING
BLANKETED
NOTES:
1. SEED AND SOIL AMENDMENTS SHALL BE APPLIED ACCORDING TO THE RATES IN THE PLAN DRAWINGS
PRIOR TO INSTALLING THE BLANKET.
2. PROVIDE ANCHOR TRENCH AT TOE OF SLOPE IN SIMILAR FASHION AS AT TOP OF SLOPE.
3. SLOPE SURFACE SHALL BE FREE OF ROCKS, CLODS, STICKS, AND GRASS.
4. BLANKET SHALL HAVE GOOD CONTINUOUS CONTACT WITH UNDERLYING SOIL THROUGHOUT ENTIRE
LENGTH. LAY BLANKET LOOSELY AND STAKE OR STAPLE TO MAINTAIN DIRECT CONTACT WITH SOIL. DO
NOT STRETCH BLANKET.
5. THE BLANKET SHALL BE STAPLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
6. BLANKETED AREAS SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT UNTIL PERENNIAL
VEGETATION IS ESTABLISHED TO A MINIMUM UNIFORM 70% COVERAGE THROUGHOUT THE BLANKETED AREA. DAMAGED OR DISPLACED BLANKETS SHALL BE RESTORED OR REPLACED WITHIN 4 CALENDAR
DAYS.
PREPARE SEED BED
(INCLUDING APPLICATION OF
LIME, FERTILIZER AND SEED)
PRIOR TO BLANKET
INSTALLATION
OVERLAP BLANKET ENDS 6" MIN.
W/ THE UPSLOPE BLANKET
OVERLAYING THE DOWNSLOPE
BLANKET (SHINGLE STYLE).
STAPLE SECURELY
THE BLANKET SHOULD
NOT BE STRETCHED; IT
MUST MAINTAIN GOOD
SOIL CONTACT
STAPLE PATTERN "B"
*LOCATION OF SEAM STITCH WILL VARY DEPENDING
ON NORTH AMERICAN GREEN PRODUCT TYPE:
FOR BLANKETS WITH THE OPTIONAL NORTH AMERICAN
GREEN DOT SYSTEM PLACE STAPLES/STAKES
THROUGH EACH OF THE RED COLORED DOTS.
*2"-5"
3.3'
1.15 STAPLES PER SQ. YD.
TM
*2"-5"
SEAM STITCH
3.3'
3'
6'
1.6'
B
TM
2 MIN.(TYP.)
1' MIN.
CURB
INSTALLATION DETAIL
ISOMETRIC VIEW
PLAN VIEW
SCALE:6 NONE
FILTER BAG INLET PROTECTION - TYPE C INLET
STANDARD CONSTRUCTION DETAIL #4-15
2'
4'
3'
WIDTH LENGTH
TOP OF CURB
FLOW
ELEVATION VIEW
EXTEND BERM OVER CURB
IF RUNOFF IS BYPASSING
INLET ON LANDWARD SIDE
NOTES:
1. MAXIMUM DRAINAGE AREA= 1/2 ACRE
2. INLET PROTECTION SHALL NOT BE REQUIRED FOR INLET TRIBUTARY TO SEDIMENT BASIN OR
TRAP. BERMS SHALL BE REQUIRED FOR ALL INSTALLATIONS.
3. ROLLED EARTHEN BERM SHALL BE PROVIDED AND MAINTAINED IMMEDIATELY DOWN GRADIENT
OF THE PROTECTED INLET UNTIL ROADWAY IS STONED. ROAD SUB-BASE BERM SHALL BE
MAINTAINED UNTIL ROADWAY IS PAVED. SIX INCH MINIMUM HEIGHT ASPHALT BERM SHALL BE
MAINTAINED UNTIL ROADWAY SURFACE RECEIVES FINAL COAT.
4. AT A MINIMUM, THE FABRIC SHALL HAVE A MINIMUM GRAB TENSILE STRENGTH OF 120 LBS, A
MINIMUM BURST STRENGTH OF 200 PSI, AND A MINIMUM TRAPEZOIDAL TEAR STRENGTH OF 50
LBS. FILTER BAGS SHALL BE CAPABLE OF TRAPPING ALL PARTICLES NOT PASSING A NO. 40
SIEVE.
5. INLET FILTER BAGS SHALL BE INSPECTED ON A WEEKLY BASIS AND AFTER EACH RUNOFF EVENT.
BAGS SHALL BE EMPTIED AND RINSED OR REPLACED WHEN HALF FULL OR WHEN FLOW
CAPACITY HAS BEEN REDUCED SO AS TO CAUSE FLOODING OR BYPASSING OF THE INLET.
DAMAGED OR CLOGGED BAGS SHALL BE REPLACED. A SUPPLY SHALL BE MAINTAINED ON SITE
FOR REPLACEMENT OF BAGS. ALL NEEDED REPAIRS SHALL BE INITIATED IMMEDIATELY AFTER
THE INSPECTION. DISPOSE OF ACCUMULATED SEDIMENT AS WELL AS ALL USE BAGS ACCORDING
TO THE PLAN NOTES
6. DO NOT USE ON MAJOR PAVED ROADWAYS WHERE PONDING MAY CAUSE TRAFFIC HAZARDS.
SANDBAG, FILTER LOG,
COMPOST SOCK OR
FILTER TUBE
EXPANSION RESTRAINT
(1/4" NYLON ROPE)
2" x 2" x 3/4"
RUBBER BLOCK
1" REBAR FOR BAG REMOVAL FROM
INLET REMOVAL FROM INLET
BERM
BERM
STORM
INLET
384384
INV IN 6" HDPE=378.7'
INV IN 6" HDPE=378.7'
INV IN 6" HDPE=378.6'
INV IN 6" HDPE=378.6'
INV IN 12" HDPE=382.7'
GRATE=391.76'
INV IN 6" HDPE=383.50' (FD)
INV IN 6" HDPE=386.10' (RD)
INV IN 6" HDPE=388.00' (RD)
INV OUT 12" HDPE=383.44' (FD)
INV IN 6" HPDE=382.8' (RD)
INV IN 6" HDPE=382.8 (FD)
A
B
2 3
C
D
1 2 3
4 5 6
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
Entech Engineering - Printed: May. 11, 2026 H:\0004644.029\04-CAD\SheetFiles\New Work\C-101.dwgLa st
E di te d by : m hi es te r
/1
1/
BI
D
D
IN
G C
AD
TO
W
N
SH
IP
O
F
SP
R
IN
G
TO
W N
SH
I…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .