Copy_of_Attachment_A_-_Meteorological_Stations_-_Wind_Speed_and_Direction_(2D).xlsx
XLSX spreadsheet 12 KB Posted
- Attached to
- METEOROLOGICAL EQUIPMENT AND INSTALLATION Federal contract opportunity
- Solicitation number
- 18-284-SOL-0004
About this file
PART NUMBERS, QTY
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Met_Stations_RFP_FINAL.docx | DOCX document | |
| Attachment_B_-_Meteorological_Station__Installation_Requirements.docx | DOCX document | |
| 1767002_TC-001.00_Ver00-36X48.pdf | ||
| 1767002_TC-100.00_Ver00-36X48.pdf | ||
| 1767002_TC-400.00_Ver00-36X48.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Equipment List
| Meteorological Stations - Wind Speed and Direction (2D) | |||||||
| Suggested | Approximate | ||||||
| Quantity | Equipment | Manufacturer | Model | cost (ea) | sub-total | ||
| 6 | Heated, 2D Sonic Anemometer | R.M. Young | 86004 | 2 spare for calibration change outs | 2000 | 12000 | |
| 6 | Data loggers (with extended temperature calibration) | Campbell Scientific | CR-6 or CR-1000 | 2 spare for calibration change outs | ($1700 to $2000) | 2000 | 12000 |
| 6 | Barometric pressure sensors | R.M. Young | 61302V | 2 spare for calibration change outs | 700 | 4200 | |
| 4 | Pressure port with offset bracket | R.M. Young | 61002 | 175 | 700 | ||
| 4 | Network adapters (if CR1000 used) | Campbell Scientific | NL-121 | ($300 to $525) | 525 | 2100 | |
| 4 | DC-DC converters (to stabilize 12VDC to sensors and loggers) | XP Power | DTE40 | 70 | 280 | ||
| 4 | Lead acid backup batteries (10 Ahr each) | ||||||
| 4 | 24 VDC, 3.5A power supplies (wall warts OK) | ||||||
| 2 | 2 Stainless Steel enclosures, NEMA Type 4x, 16" x 14" with back panels | Hoffman Enclosures Inc. | A1614CHNFSS | 750 | 1500 | ||
| 4 | Weather proof, through enclosure connectors for power | 10 | 40 | ||||
| 4 | Weather proof, through enclosure connectors for sonics | 10 | 40 | ||||
| 4 | Weather proof, through enclosure connectors for modems | 10 | 40 | ||||
| 2 | Lightning protection | ||||||
| 2 | Folding or telescoping poles or mounting booms | Site specific | To mount met stations on | ||||
| 2 | Aluminum Cross arm (1.5 to 2 meters) with two 1" uprights at opposing ends | To mount sonics on | |||||
| 2 | Computer/servers (1 TB hard drive, windows 7 or windows 10 operating system) | For data collection, data archiving and web hosting | ($1000 to $1500) | 1500 | 3000 | ||
| 2 | UPS for computer | 350 | 700 | ||||
| 2 | LoggerNet software | Campbell Scientific | Version 4.4.2 | 600 | 1200 | ||
| 2 | LNDB LoggerNet Database software | Campbell Scientific | Version 1.2 | 300 | 600 | ||
| 2 | Data plans for networking loggers and LNDB | ||||||
| Misc | cabling, wiring, U-bolts, etc. | Site specific | |||||
| Total | 38400 | ||||||
| Out years | |||||||
| 4 | Annual calibration of sonics | R.M. Young | NIST traceable | ($250 to $500) | 500 | 2000 | |
| 4 | Bi-annual calibration of data loggers | Campbell Scientific | with XT | 365 | 1460 | ||
| 2 | Annual inspection of Met stations and mounting hardware | ($1500 to $2500) | $1,500 | $3,000 | |||
| Total | 6460 |
File details come from the government source that posted it.