1767002_TC-001.00_Ver00-36X48.pdf

PDF 248 KB Posted

Attached to
METEOROLOGICAL EQUIPMENT AND INSTALLATION Federal contract opportunity
Solicitation number
18-284-SOL-0004
Issued by
Department of Health and Human Services Program Support Center

About this file

DRAWING 3

View the file

Other files for this federal contract opportunity

Other files attached to METEOROLOGICAL EQUIPMENT AND INSTALLATION, newest first.
File Type Posted
Attachment_B_-_Meteorological_Station__Installation_Requirements.docx DOCX document
Copy_of_Attachment_A_-_Meteorological_Stations_-_Wind_Speed_and_Direction_(2D).xlsx XLSX spreadsheet
1767002_TC-100.00_Ver00-36X48.pdf PDF
1767002_TC-400.00_Ver00-36X48.pdf PDF
Met_Stations_RFP_FINAL.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABOVE FINISHED FLOOR

1. SEE TELECOMMUNICATIONS CABLING SPECIFICATIONS (SECTIONS: 270000, 271000, 271100, 272000, 272100, 27500, 275100, AND 275200) FOR ADDITIONAL

INSTALLATION INFORMATION.

2. ALL HORIZONTAL UTP CABLES SHALL BE HOMERUN FROM THE IDF CLOSET TO THE OUTLET LOCATION.

3. CABLES SHALL BE TERMINATED ON RACK MOUNTED CAT 6 PATCH PANELS UON. ALL CABLES SHALL BE TERMINATED ON CAT 6 8-PIN MODULAR JACKS AT

THE OUTLET LOCATION UON.

4. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND MOUNTING HEIGHTS FOR ALL OUTLETS. ALL CONDUITS, BACK BOXES AND STUB-UPS ARE BY

OTHERS.

5. DO NOT DEVIATE FROM NUMBERING SCHEME DENOTED ON DRAWINGS UNLESS APPROVED IN WRITING BY OWNER/ENGINEER.

1. PROVIDE ALL CONDUITS, SLEEVES, STUB-UPS AND OUTLET BOXES INDICATED ON THE DRAWINGS.

2. ALL CONDUITS, STUB-UPS AND CONDUIT SLEEVES SHALL BE EMT U.O.N.

3. PROVIDE (1) CONDUIT WATERFALL AT EACH END OF EMT CONDUIT (PANDUIT # CWF400 OR EQUAL)

4. ALL CONDUIT RUNS SHALL BE FULLY COORDINATED WITH OTHER TRADES PRIOR TO INSTALLATION.

5. ALL CONDUITS SHALL BE INSTALLED WITH A MAXIMUM OF TWO (2) 90-DEGREE BENDS, OR THEIR FUNCTIONAL EQUIVALENT, BETWEEN PULL BOXES. PULL

BOXES SHALL BE SIZED AS INDICATED ON THE DRAWINGS.

6. THERE SHALL BE NO MORE THAN 100 LINEAR FEET OF CONDUIT BETWEEN PULL BOX LOCATIONS.

7. CONDUITS SHALL EXIT PULL BOXES ON THE SIDE OPPOSITE FROM WHICH THEY ENTER. PULL BOXES SHALL NEVER BE USED IN LIEU OF A BEND.

8. PROVIDE NON-METALLIC BUSHINGS ON THE ENDS OF ALL CONDUITS. ALL CONDUITS SHALL BE PROVIDED WITH DRAG LINES AND TRUE TAPE.

9. ALL CONDUITS SHALL BE GROUNDED FOR CODE 4 PER TIA/EIA 607. ADDITIONALLY, ALL CONDUITS ENTERING EQUIPMENT ROOMS SHALL BE BONDED TO THE TELECOMMUNICATIONS GROUND BAR IN THE ROOM WITH CONTINUOUS #6 AWG GROUND CONDUCTOR.

10. CONTRACTOR SHALL FIRESTOP ALL CONDUITS SLEEVES, CABLE TRAY OPENINGS AND WALL PENETRATIONS. WALL PENETRATIONS SHALL BE INTERNALLY

FRAMED WITH METAL FRAMING STUDS TO FACILITATE FIRE STOPPING.

11. ALL CONDUITS SHALL BE LABELED WITH TO/FROM DESIGNATIONS.

12. SUBMIT CONDUIT ROUTING SHOP DRAWINGS FOR APPROVAL PRIOR TO INSTALLATION AND PROVIDE AS-BUILT DRAWINGS SHOWING EXACT CONDUIT

ROUTES AT THE COMPLETION OF THE WORK.

CONDUIT

CLOSET

ALL THREADED ROD

AMERICAN WIRE GAUGE

AFF

ATR

C

CL

AWG

CEILING

DRAWING

COMMUNICATIONS

EXTENDED FREQUENCY

EMPTY CONDUIT

GROUND

EQUIPMENT ROOM

FIRE RATED

FURNISHED BY OTHERS

HUNG CEILING

CLG

COMMS

EC

EF

DWG

ER

FR

FBO

G

HC

MOUNTED

MAIN DISTRIBUTION FRAME

LOCAL AREA NETWORK

INTERMEDIATE DISTRIBUTION FRAME

NOT TO SCALE

PRIVATE BRANCH EXCHANGE

NOT IN CONTRACT

NOT BEING ISSUED

MULTIPAIR SHIELDED CABLE

MOUNTING

IDF

LAN

MDF

MTD

MSC

NBI

NIC

NTS

MTG

INTERCOMI

PANEL

ROOM

TURRET

TELECOMMUNICATIONS

SHIELDED TWISTED PAIR

TYPICAL

TELEVISION

UNSHIELDED TWISTED PAIR

TELECOM SERVICE ENTRANCE ROOM

UNLESS OTHERWISE NOTED

PNL

RM

STP

T

TSER

TV

TYP

UTP

UON

TELECOM

VOICE

VOICE RECORDER

WALL CABINET

WATERPROOF

WIDE AREA NETWORK

V

VR

WC

WP

WAN

PBX

INTERMEDIATE DISTRIBUTION ROOMIDR

MAIN DISTRIBUTION ROOMMDR

POINT OF ENTRYPOE

WIRELESS ACCESS POINTWAP

ABBREVIATIONS

GENERAL NOTES

CONDUIT INSTALLATION NOTES:

TC-001.00

TC-100.00

DRAWING #

200 PARK AVE TELECOM ABBREVIATIONS, SYMBOLS LIST, DRAWING LIST AND GENERAL NOTES

DETAIL REFERENCE IDENTIFIERDETAIL No.

REFERENCE LEGEND

DETAIL DWG No.

NOTE REFERENCE

DETAIL REFERENCE IDENTIFIER

ELEVATION REFERENCE IDENTIFIER

DRAWING REFERENCE IDENTIFIER

DETAIL No.

DETAIL ID

DETAIL No.

ELEVATION ID

REFERENCE ID

DETAIL No.

DWG FROM WHICH DETAIL IS CUT

ANTENNA ELEVATIONS

ROOF TELECOMMUNICATIONS FLOOR PLAN

DESCRIPTION

TC-400.00

X scale drawing no.

initiated bydescriptiondaterev. no.

project name job no.

drawing drawn by date

AV SecurityTelecom

"THIS PLAN IS APPROVED ONLY FOR WORK INDICATED ON

THE APPLICATION SPECIFICATION SHEET.

ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON,

OR TO BE CONSIDERED AS EITHER BEING APPROVED

OR IN ACCORDANCE WITH APPLICABLE CODES."

TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL

JUDGMENT, THESE PLANS AND SPECIFICATIONS ARE IN

COMPLIANCE WITH THE NEW YORK CITY ENERGY CONSERVATION

CODE

1 182206 ISSUED FOR REVIEW