B09_Questions_and_Answers_01_0001.pdf

PDF 173 KB Posted

Attached to
Water Source Test Well Drilling, Independence, Cal Federal contract opportunity
Solicitation number
140P8122R0002
Issued by
Department of the Interior National Park Service Pacific West Region

About this file

This document contains questions and answers regarding solicitation number 140P8122R0002 for water source test well drilling at Manzanar National Historic Site. The questions and answers provide specifications for cement and grout materials to conform to Inyo County requirements, note the site elevation is 4018 feet, and clarify that the contractor has discretion over the diameter and use of a temporary conductor casing. No additional details are provided on the requirements for the federal contract opportunity.

View the file

Other files for this federal contract opportunity

Other files attached to Water Source Test Well Drilling, Independence, Cal, newest first.
File Type Posted
Sol_140P8122R0002_Amd_0001.pdf PDF
B08_Invoice_Payment_Request.docx DOCX document
B08_Release_of_Claims.pdf PDF
A04_Construction_Specifications.pdf PDF
B08_Transmittal.pdf PDF
B08_Contract_Price_Schedule.pdf PDF
B03_General_Decision_CA20220020.pdf PDF
Sol_140P8122R0002.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

140P8122R0002 Questions and Answers

May 16, 2022

What is the elevation of the site for this job?

4018 feet

What type of Cement should be used?

The cement for the Grout Surface Seal must conform specification 33 11 11 Test Wells subparts 1.7.A and 2.1.C. Note that Inyo County's requirements, per 1.7.A, take precedence as they are the AHJ issuing the Well Drilling Permit.

Standard Cement/Sand Slurry/Bentonite?

For Sand-Cement Grout for the Grout Surface Seal the materials must conform to specification 33 11 11 Test Wells subparts 1.7.A and 2.1.C. Note that Inyo County's requirements, per 1.7.A, take precedence as they are the AHJ issuing the Well Drilling Permit. Prospective bidders are recommended to check with Inyo County regarding if they will allow the use of bentonite for the Grout Surface Seal for this test well as they have restricted the use of bentonite in certain locations in Inyo County.

For Line item #2, can you provide any additional information on what size conductor casing is to be used? 10"? 12"? It is unclear based on the Scope of Work

The use of a temporary conductor casing is at the discretion of the Contractor and likewise the diameter of the temporary conductor casing is at the discretion of the Contractor. Please refer to specification 33 11 11 Test Wells subpart 3.3.A for additional information on the temporary conductor casing.