A-3_DETAILS_0002.pdf

PDF 228 KB Posted

Attached to
MFB-ROOF REPLACEMENT Federal contract opportunity
Solicitation number
140G0221R0013
Issued by
Department of the Interior US Geological Survey Office of Acquisitions and Grants

About this file

This document contains AutoCAD drawings detailing roofing system specifications for a project at the National Wildlife Health Laboratory in Madison, Wisconsin. The drawings specify an EPDM roofing membrane with insulation and metal decking. Details include roof drains, pipe boots, expansion joints, walkways, and other components.

The related federal contract opportunity is a solicitation issued by the Department of the Interior US Geological Survey Office of Acquisitions and Grants for an MFB-Roof Replacement project. The solicitation number is 140G0221R0013 and the opportunity type is listed as a solicitation. No further details are provided on pricing terms, response dates, or other requirements in the solicitation.

View the file

Other files for this federal contract opportunity

Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text Waterstop

AutoCAD SHX Text Clamping Ring

AutoCAD SHX Text Insulation

AutoCAD SHX Text Approved

AutoCAD SHX Text Existing

AutoCAD SHX Text Metal Deck

AutoCAD SHX Text 0.060" EPDM Roof

AutoCAD SHX Text Membrane

AutoCAD SHX Text Rib

AutoCAD SHX Text Prefabricated Pipe

AutoCAD SHX Text High Profile

AutoCAD SHX Text Edge Caulk

AutoCAD SHX Text Boot W/Pre-Applied Tape

AutoCAD SHX Text Cut Above Rib To Fit Desired Pipe Size.

AutoCAD SHX Text Pre-Applied

AutoCAD SHX Text Tape

AutoCAD SHX Text Primer

AutoCAD SHX Text %%UNOTE%%U: Termination Ring Is Required

AutoCAD SHX Text e802.dxf

AutoCAD SHX Text Treated Wood Nailer

AutoCAD SHX Text Approved

AutoCAD SHX Text Insulation

AutoCAD SHX Text Barrier

AutoCAD SHX Text New Vapor

AutoCAD SHX Text Approved Fastener

AutoCAD SHX Text Membrane

AutoCAD SHX Text Seam Adhesive

AutoCAD SHX Text Bar Cover Tape

AutoCAD SHX Text

EPDM

AutoCAD SHX Text High Profile

AutoCAD SHX Text Edge Caulk

AutoCAD SHX Text Each 12" o.c.

AutoCAD SHX Text Approved

AutoCAD SHX Text Existing

AutoCAD SHX Text Filler

AutoCAD SHX Text 24"o.c.

AutoCAD SHX Text

EPDM

AutoCAD SHX Text Edge Caulk

AutoCAD SHX Text Foam Tube

AutoCAD SHX Text Approved Fastener

AutoCAD SHX Text Bar Anchor

AutoCAD SHX Text

EPDM

AutoCAD SHX Text High Profile

AutoCAD SHX Text Seam Adhesive

AutoCAD SHX Text Treated Wood Nailer

AutoCAD SHX Text Approved Fastener

AutoCAD SHX Text 2" Max.

AutoCAD SHX Text 3"

AutoCAD SHX Text 0.060"

AutoCAD SHX Text Insulation

AutoCAD SHX Text Metal Deck

AutoCAD SHX Text Metal

AutoCAD SHX Text min. Typ.

AutoCAD SHX Text

OPTIONAL CONC. WALKWAY DETAIL

AutoCAD SHX Text EPDM Membrane

AutoCAD SHX Text EPDM Membrane

AutoCAD SHX Text Approved Insulation

AutoCAD SHX Text Existing Metal Deck

AutoCAD SHX Text Precast Concrete Pavers

AutoCAD SHX Text Per Specifications

AutoCAD SHX Text 3" Min.

AutoCAD SHX Text %%UNote:%%U Do Not Install Over Field Seams, Bar Covers, or Flashing Splice Joints

AutoCAD SHX Text

ROOF DRAIN DETAIL

AutoCAD SHX Text

PIPE BOOT DETAIL

AutoCAD SHX Text

EXPANSION JOINT DETAIL

AutoCAD SHX Text

GRAVEL STOP & ROOF EDGE DETAIL

AutoCAD SHX Text EPDM Membrane

AutoCAD SHX Text Approved Insulation

AutoCAD SHX Text Existing Metal Deck

AutoCAD SHX Text Walkway Pad By Roof Manufacturer

AutoCAD SHX Text (Applied With Seam Tape)

AutoCAD SHX Text

WALKWAY DETAIL

AutoCAD SHX Text 6" Thk.

AutoCAD SHX Text 0.060"

AutoCAD SHX Text 6"

AutoCAD SHX Text Existing

AutoCAD SHX Text Construction

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 0.060"

AutoCAD SHX Text A-3

AutoCAD SHX Text

AutoCAD SHX Text A-3

AutoCAD SHX Text

AutoCAD SHX Text A-3

AutoCAD SHX Text

AutoCAD SHX Text A-3

AutoCAD SHX Text

AutoCAD SHX Text A-3

AutoCAD SHX Text 4A

AutoCAD SHX Text New Vapor

AutoCAD SHX Text Barrier

AutoCAD SHX Text New Vapor

AutoCAD SHX Text Barrier

AutoCAD SHX Text 4" min.

AutoCAD SHX Text 3" min.

AutoCAD SHX Text Edge Caulk

AutoCAD SHX Text Continuous

AutoCAD SHX Text 3" min.

AutoCAD SHX Text Pipe Boot

AutoCAD SHX Text Flange

AutoCAD SHX Text Field Seam

AutoCAD SHX Text

FIELD SPLICES MUST BE LOCATED AT

AutoCAD SHX Text

LEAST 6 INCHES OUTSIDE THE DRAIN SUMP

AutoCAD SHX Text

INSULATION

AutoCAD SHX Text

CUT-OFF MASTIC

AutoCAD SHX Text

WATER

AutoCAD SHX Text

EPDM MEMBRANE

AutoCAD SHX Text

2" MIN.

AutoCAD SHX Text

SHOWN

AutoCAD SHX Text

SEALANT AS

AutoCAD SHX Text

APPLY LAP

AutoCAD SHX Text NOTES: 1. FOR EXPANSION JOINT INTERSECTIONS AND INTERSECTIONS BETWEEN EXPANSION JOINTS TO WALL OR EDGING, USE 3 LAYERS OF UNCURED ELASTOFORM FLASHING WITH EACH LAYER 3 INCHES (8 cm) LARGER THAN PREVIOUS LAYER IN ALL DIRECTIONS. 2. WIDTH OF JOINT SHALL BE A MINIMUM OF 3/4 INCHES (19 mm) AND SHALL NOT EXCEED 3 INCHES (8 cm). 3. HP LOCKING SEAM PLATES OR POLYMER SEAM PLATES ARE REQUIRED IN LIEU OF SEAM FASTENING PLATES FOR MECHANICALLY-FASTENED ROOFING SYSTEMS OVER STEEL DECKS. 4. SURE-SEAL PRIMER MUST BE APPLIED TO MEMBRANE SURFACE PRIOR TO APPLYING PRESSURE-SENSITIVE FLASHING OR SECURTAPE. 5. LAP SEALANT MUST BE APPLIED ALONG PRESSURE-SENSITIVE FLASHING AND SECURTAPE AT INTERSECTIONS WITH FIELD SPLICES AND FLASHING OVERLAPS AS SHOWN ABOVE.

AutoCAD SHX Text SecurTAPE

AutoCAD SHX Text

2" MIN.

AutoCAD SHX Text

FLASHING

AutoCAD SHX Text

2" MIN.

AutoCAD SHX Text

LAP SEALANT

AutoCAD SHX Text

PRESSURE-SENSITIVE

AutoCAD SHX Text

(NOTE 5)

AutoCAD SHX Text

OVERLAP AT

AutoCAD SHX Text

2" MIN.

AutoCAD SHX Text

2" MIN.

AutoCAD SHX Text

2" MIN.

AutoCAD SHX Text

SPLICE

AutoCAD SHX Text

FIELD

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

1. REMOVE ALL LEAD AND OTHER FLASHING.

AutoCAD SHX Text

2. ALL BOLTS OR CLAMPS MUST BE IN PLACE TO PROVIDE

AutoCAD SHX Text

CONSTANT COMPRESSION ON WATER CUT-OFF MASTIC.

AutoCAD SHX Text

3. CUT THE MEMBRANE SO IT EXTENDS A MINIMUM OF 1/2"

AutoCAD SHX Text (13 mm) FROM THE ATTACHMENT POINTS OF THE DRAIN

AutoCAD SHX Text

CLAMPING RING.

AutoCAD SHX Text

4. HOLE IN MEMBRANE MUST EXCEED SIZE OF DRAIN PIPE.

AutoCAD SHX Text

5. INSULATION TAPER SHALL NOT BE STEEPER THAN 6"

AutoCAD SHX Text

VERTICAL) IN 12" ( (HORIZONTAL).

AutoCAD SHX Text

6. ROOF DRAIN SIZE AND NUMBER OF DRAINS SHALL BE IN

AutoCAD SHX Text

ACCORDANCE WITH LOCAL CODES.

AutoCAD SHX Text

PEDESTAL AND CHIMNEY CAP DETAIL

AutoCAD SHX Text

AutoCAD SHX Text A-3

AutoCAD SHX Text Metal Fascia

AutoCAD SHX Text Clip

AutoCAD SHX Text Approved Fastener

AutoCAD SHX Text Each 12"o.c.

AutoCAD SHX Text Metal Fascia

AutoCAD SHX Text Each 24" o.c.

AutoCAD SHX Text (See Note)

AutoCAD SHX Text EPDM Membrane

AutoCAD SHX Text 1/2"

AutoCAD SHX Text A-3

AutoCAD SHX Text

AutoCAD SHX Text

EXPANSION JOINT DETAIL

AutoCAD SHX Text

STAINLESS STEEL CLAMP

AutoCAD SHX Text

CAULK IN FIELD W/ HI-TEMP CAULKING

AutoCAD SHX Text

THYCURB MODEL TP-S CUSTOM DIMENSIONS TO FIT OVER EXISTING INCINERATOR TOP.

AutoCAD SHX Text

STATUS

AutoCAD SHX Text

NATIONAL WILDLIFE HEALTH LABORATORY

AutoCAD SHX Text

MADISON, WI

AutoCAD SHX Text 07-20-2000

AutoCAD SHX Text

CENTREVILLE, VA 20120

AutoCAD SHX Text

ENGINEERING DESIGN AND CONSULTING

AutoCAD SHX Text

NETWORK PROFESSIONAL ENGINEERING

AutoCAD SHX Text

15422 MARTINS HUNDRED DRIVE

AutoCAD SHX Text

PH: 703.502.1061 FX: 703.502.0953

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

REVISION

AutoCAD SHX Text A-3

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DRAWING NO:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DATE

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

NPE200035A-3

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text

BY

AutoCAD SHX Text

CLAMPING RING

AutoCAD SHX Text NOTE: DO NOT SECURE/FASTEN WALKWAY EPDM MEMBRANE. ALLOW PRECAST CONC. PAVERS TO HOLD IN PLACE.

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text All wood nailers to be

AutoCAD SHX Text approved treated material.

AutoCAD SHX Text Attachment of wood nailer

AutoCAD SHX Text to be accomplished by

AutoCAD SHX Text using fasteners providing

AutoCAD SHX Text no less than 125 lbs of

AutoCAD SHX Text pullout strength and

AutoCAD SHX Text fasteners shall be spaced

AutoCAD SHX Text no greater than 24" o.c.

AutoCAD SHX Text Metal coping cap, expansion joint, and edge detail are typical only. All metal work shall be installed to sheet metal codes (SMACNA). Clean all metal prior to installation of roofing materials.