Project_Plans.pdf

PDF 7 MB Posted

Attached to
HCWC Barracks Renovation Federal contract opportunity
Solicitation number
129AC718Q0051
Issued by
Department of Agriculture Forest Service R5-Pacific Southwest Region

About this file

Plans

View the file

Other files for this federal contract opportunity

Other files attached to HCWC Barracks Renovation, newest first.
File Type Posted
129AC718Q0051-0002.pdf PDF
Site_Visit_Attendees.pdf PDF
129AC718Q0051-0001.pdf PDF
Q&A_Version_1_-_073018.docx DOCX document
WD_CA180021_dtd_010518,_Modification_0.pdf PDF
129AC718Q0051.pdf PDF
Project_Specifications.pdf PDF
Experience_Questionaire.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F

W W

26.3'

58.4'

26'

16.2'

EXISTING CONDITIONS

16.2'

16'

No Scale

N

= Open Interior Wall Area (Studs exposed)

All Ceiling Areas Removed

AC Condeser Unit

Propane Furnace In

Place; Not Installed

Electric Hot Water

Heaters Removed

All Plumbing Removed From Attic

All Electrical Wiring Removed From Attic

Service Entrance also removed

Old Electrical Load Center

Rm. 1

Rm. 2

Rm. 3

Rm. 4

Rm. 5

Bath 1

Bath 2

Lounge/Living

Rm.

Laundry

Kitchen

Porch

Entrance

Storm Damaged

Door

Storm Damaged Door.

Door Header is Missing

Trusses are 24" on center except at 17, 18, 19, and 20.

Distance between truss 17 and 18 = 14"

Distance between truss 18 and 19 = 32"

Distance between truss 19 and 20 = 25"

Spacing allows for installation of

HVAC distribution box and ductwork, see sheet 21.

5 ton A/C Fan Coil removed from top of furnace stored in Rm. 3 with 6 lb. bottle of R-22 refrigerant to become contractor property and removed from the site to be reused/reinstalled elsewhere along with the existing AC Condenser Unit.

Light fixtures and fluorescent bulbs removed from ceiling areas to become contractor property and removed from the site to be reused/reinstalled elsewhere, stored in Room 3.

GROUND LEVEL -PLAN VIEW

No Scale

TRUSS LAYOUT AND NUMBERING SCHEMATIC AT CEILING LEVEL -PLAN VIEW

Trusses are numbered and marked on site.

No Scale

AutoCAD SHX Text

AutoCAD SHX Text

NONE

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Existing Conditions

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

AutoCAD SHX Text Repair Lower Barracks Phase II

EXISTING CONDITIONS

No Scale

NORTH WALL

WEST WALL

SOUTH WALLS AND EAST WALLS AT KITCHEN

AutoCAD SHX Text

AutoCAD SHX Text

NONE

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Existing Conditions

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

EXISTING CONDITIONS

NORTH KITCHEN WALL AND EAST WALL MAIN BUILDING

NOTE: There is a 4" wide strip of unfinished wall area around the building perimeter at the top of the wall where the truss tails extend out into the soffits. Soffit vents are not currently installed. Soffit areas are not yet painted.

AutoCAD SHX Text

AutoCAD SHX Text

NONE

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Existing Conditions

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

INSTALL NEW EVE

VENT BATTERIES

THESE LOCATIONS

INSTALL NEW EVE

VENT BATTERIES

THESE LOCATIONS

INSTALL NEW EVE

VENT BATTERIES

THESE LOCATIONS

4 ea. 2" Diameter Holes

24" ± Typical

EVE VENT BATTERY

No Scale

Galvanized Steel Hardware

Cloth, " Mesh, Install over Holes.

BLOCK AND SEAL EXISTING

EVE VENTS BATTERIES

THESE LOCATION ONLY

EXISTING

VENTS

EXISTING

VENTS

EXISTING

VENTS

EXISTING

VENTS

EXISTING EVE

VENT BATTERY

EXISTING

VENTS

ATTIC VENTILATION AT EVES

No Scale

N

NOTE: AN AIRSPACE OF NOT LESS THAN ONE INCH SHALL BE PROVIDED BETWEEN

THE INSULATION AND THE ROOF SHEATHING. MAINTAIN AREA IN FRONT OF

VENTS CLEAR OF INSULATION.

4.5"

Galvanized Steel Hardware

Cloth, " Mesh

1.5" Nominal

LOUVERED SOFFIT VENT

No Scale

16"

8"

16 in. x 8 in. Aluminum Louvered

Soffit Vent in Mill Finish

Provide/Install 17 each new in addition to the existing Eve Vent Batteries at locations shown.

Provide/Install 7 each new soffit vents on underside of soffit at locations shown.

INSTALL SOFFIT VENT

INSTALL SOFFIT VENT

INSTALL 16" X 14" GALVANIZED STEEL

LOUVERED ATTIC VENT OVER WINDOW ON PORCH AT

THIS LOCATION. MATCH EXISTING VENTS AT GABLE ENDS.

SEE SHEET 6 FOR DETAIL.

INSTALL SOFFIT VENTS

INSTALL SOFFIT VENT

INSTALL SOFFIT VENTS

AutoCAD SHX Text

AutoCAD SHX Text

NONE

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

ATTIC VENTS

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

AutoCAD SHX Text Repair Lower Barracks Phase II

AutoCAD SHX Text

AutoCAD SHX Text

NONE

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

ATTIC VENTS

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

C:\Users\tracytotten\Pictures\2018\01.26.18\IMG_3150.JPG

EXISTING PORCH ELEVATION

EXISTING

FRAMING

14"

16"

16" x 14" ALUMINUM LOUVERED

ATTIC VENT IN MILL FINISH

REMOVE/ MODIFY

EXISTING FRAMING

MEMBER TO PROVIDE

FOR INSTALLATION

INSTALL VENT AT THIS

LOCATION JUST BELOW

PLYWOOD

MODIFIED PORCH ELEVATION

MAINTAIN TYVEX

HOUSEWRAP ON WALL

AS IS EXSITING

ENCLOSE UNDERSIDE OF PORCH.

USE

" CDX PYWOOD TO

COVER BOTTOM OF JOISTS.

PREP AND PAINT TO MATCH EXTERIOR

WALL AREAS.

9"

TOP PLATE

TO REMAIN

23"

No Scale

No Scale

AutoCAD SHX Text

AutoCAD SHX Text

NONE

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

ATTIC VENT AT PORCH

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

EXTERIOR ELEVATION WEST

4"

21'- 4"

22'

21'

23'- 8"

31'- 2"

58'- 6"

16"

16"

16"

SEWER CLEANOUT

LPG SERVICE

ENTRANCE

3" WIDE TRIM

INSTALL NEW SIDING

AREAS READY TO INSTALL

REMOVE AND DISPOSE

ALL REMAINING EXISTING SIDING

INSTALL NEW SIDING WEST ELEVATION

INSTALL NEW SIDING

USE PPG PREFINISHED LP SMARTSIDE

LAP SIDING TO MATCH EXISTING LAP SIDING

16" X 16 ' TRIPLE LAP PANELS

COLOR: "PRAIRIE WHEAT"

WINDOWS TO REMAIN

REPLACE EXISTING SCREENS

WITH NEW.

8'

44 1/2" (Typical)

41" (Typical)

8'-5"

8'-5" 41.5"

41.5"

PAINT TRIM TO MATCH

SIDING COLOR

"PRAIRIE WHEAT"

EXISTING WINDOW TRIM.

PAINT NEW TRIM DARK BROWN TO MATCH

EXISTING COLOR (Typical).

WHEN SIDING IS REMOVED IT IS EXPECTED THAT A CELLULOSE

FIBERBOARD WILL BE UNDERNEATH THE HOUSE WRAP TO REMAIN.

WOODPECKERS HAVE PENETRATED THESE MATERIALS AND A

SMALL AMOUNT OF BIRD/BAT GUANO

IS EXPECTED TO BE ENCOUNTERED AT THIS LOCATION

WITHIN THE WALL. REMOVE AND DISPOSE ANY GUANO PRESENT

IN A WETTED CONDITION. WEAR APPROPRIATE PERSONAL

PROTECTIVE EQUIPMENT FOR ABATEMENT.

PAINT TRIM TO MATCH

SIDING COLOR

"PRAIRIE WHEAT"

3" WIDE TRIM

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

EXTERIOR ELEVATION NORTH

EXISTING HOSE

BIB TO REMAIN

3" x 3" x 4' TELEPHONE

SERVICE; PEDESTAL TO

REMAIN.

WALL CAVITY WHERE ELECTRICAL

SERVICE PANEL WAS INSTALLED.

INSTALL FRAMING AND HOUSEWRAP

COVER WITH NEW ELECTRICAL

SERVICE PANEL ON EXTERIOR OF

WALL.

REMOVE AND DISPOSE

ALL REMAINING EXISTING SIDING.

INSTALL NEW SIDING NORTH

ELEVATION

3" WIDE TRIM

PAINT EXPOSED FACE OF

BARGE RAFTER DARK BROWN

EXISTING 6" X 6" X 12"

GUTTER BUS ELECTRICAL

SERVICE FOR A/C CONDENSER

UNIT.

INSTALL NEW SIDING:

AREA IS READY FOR NEW

SIDING TO BE INSTALLED.

USE PPG PREFINISHED LP SMARTSIDE

LAP SIDING TO MATCH EXISTING LAP SIDING

16" X 16 ' TRIPLE LAP PANELS

COLOR: "PRAIRIE WHEAT"

EXISTING SAFETY SWITCH

DISCONNECT FOR ELECTRICAL

SERVICE FOR A/C CONDENSER UNIT.

EXISTING EXTERIOR AREA LIGHTS

REPLACE WITH SAME STYLE FIXTURES; USE LED

LIGHTS THIS LOCATION.

8"

26'- 4"

5'

7' - 8"

REMOVE AND REPLACE WITH NEW

ELECTRICAL SAFETY SWITCH, CONDUIT

AND GUTTER BUSS; NEW ELECTRICAL

SERVICE FOR A/C CONDENSER UNIT.

1/4" TUBING WITH CONTROL

VALVE INSIDE OF WALL.

ACCESSIBLE FROM BEDROOM

CLOSET. SEE DETAIL SHEET 10.

14"

16"

PAINT SIDING TRIM TO MATCH

SIDING COLOR, "PRAIRIE

WHEAT" (Typical)

3" WIDE TRIM AT

ATTIC VENT, PAINT

DARK BROWN

3" WIDE TRIM

INSTALL NEW

120VAC GFCI

DUPLEX ELECTRICAL

SERVICE OUTLET.

USE NEMA 3R

ENCLOSURE WITH

HINGED COVER DOOR.

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

EXTERIOR ELEVATION SOUTH

16"

14"

6"

5'- 3"

26'- 4"

7' - 7"

8"

EXISTING NEW SIDING

NO INSTALLATION WORK

THIS AREA SOUTH ELEVATION.

PAINT TRIM AT BARGE

RAFTER AND WINDOWS

DARK BROWN (Typical)

REMOVE AND DISPOSE OF

EXISTING DOOR AND FRAME.

REPLACE WITH NEW DOOR AND

FRAME, MATCH EXISTING DOOR.

EXISTING STRUCTURAL

FRAMING FOR DOOR IS

NON STANDARD AND SHALL

BE REPLACED, SEE DETAIL

SHEET 10.

USE PPG PREFINISHED LP SMARTSIDE

LAP SIDING TO MATCH EXISTING LAP SIDING

16" X 16 ' TRIPLE LAP PANELS

COLOR: "PRAIRIE WHEAT"

45"

42"

42"

44"

6' - 5

" 6' - 5

WINDOWS TO REMAIN

REPLACE EXISTING SCREENS WITH NEW

PAINT SIDING TRIM TO MATCH

SIDING COLOR, "PRAIRIE

WHEAT" (Typical)

3" WIDE TRIM AT

ATTIC VENT, PAINT

DARK BROWN

3" WIDE TRIM

3" WIDE TRIM

No Scale

INSTALL NEW SIDING:

AREA IS READY FOR NEW

SIDING TO BE INSTALLED.

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

VALVE IN NORTH WALL

Wall cavity where electrical service panel was installed.

Existing safety switch disconnect for electrical service for A/C condenser unit.

Approximate location of valve in north wall see sheet 8.

7.5"

7"

Recessed wall enclosure with tubing and valve on back wall of closet in bedroom.

When exterior siding is removed, determine if piping and valve are in service, remove if no longer needed.

If piping and valve are to remain, install nameplate describing what the valve is used for and also provide and install cover plate for access.

If piping and valve are removed, fill space with insulation and cover with drywall, prep. paint and texture to match existing wall area.

DOOR FRAMING SOUTH WALL

PLAN VIEW - EXISTING DOOR FRAMING

Rough Opening

Trimmer Stud

Full Stud

4"x 6" Header

Cripple Studs

Double Top Plate

Sole Plate

Concrete Slab

2" x 4" Framing (Typical)

NEW FRAMING - SOUTH DOOR

Existing interior partition wall frames.

Remove/replace enough to allow for new framing at south doorway.

Remove existing door and framing. Install new framing as shown prior to installing replacement door. Replacement door to match the existing door to be removed and disposed of by the Contractor.

Existing door in south wall

No Scale

No Scale

No Scale

No Scale

Bedroom #1

Bedroom #2

Hallway

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

INSTALL AT NEW SIDING AT

PORCH AREA READY TO BE

INSTALLED

5"

16"

4' - 5"

2.5'

14"

16"

6.5'

4.5'

EXTERIOR ELEVATION SOUTHEAST

Porch area

INSTALL VENT AT PORCH

SEE SHEET 6

EXISTING SINGLE PANEL OF NEW SIDING

IN PLACE NOT FULLY ATTACHED

REMOVE EXISTING HOSE BIB

IN WALL AND ANY REMAINING

INTERIOR PIPING

REMOVE AND REPLACE BOTTOM

PANEL WITH NEW SIDING

EXISTING NEW SIDING

NO INSTALLATION WORK

THIS AREA SOUTHWEST

ELEVATION.

INSTALL NEW SIDING AT 5" STRIP

READY TO BE INSTALLED

USE PPG PREFINISHED LP SMARTSIDE

LAP SIDING TO MATCH EXISTING LAP SIDING

16" X 16 ' TRIPLE LAP PANELS

COLOR: "PRAIRIE WHEAT"

WINDOW TO REMAIN

REPLACE EXISTING SCREEN WITH NEW

7' - 7"

10' - 2" 7' - 11"

3.5"

10' - 9"

3" Wide trim

3" Wide Trim

Wide post

PAINT TRIM TO MATCH

SIDING COLOR,

"PRAIRIE WHEAT"

PAINT WINDOW TRIM DARK

BROWN

PAINT SIDING TRIM TO MATCH

SIDING COLOR, "PRAIRIE

WHEAT"

3" Wide trim at attic vent, cut and fit as is necessary to fit under porch ceiling, paint dark brown

3" Wide trim

PAINT SIDING TRIM TO MATCH

SIDING COLOR, "PRAIRIE

WHEAT"

No Scale

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

10' - 9"

SOUTH KITCHEN ELEVATION

10 2 3

54 6

87 9

PAINT WINDOW TRIM DARK

BROWN

USE PPG PREFINISHED LP SMARTSIDE

LAP SIDING TO MATCH EXISTING LAP SIDING

16" X 16 ' TRIPLE LAP PANELS

COLOR: "PRAIRIE WHEAT"

WINDOW TO REMAIN

REPLACE EXISTING SCREEN WITH NEW

PAINT SIDING TRIM TO MATCH

SIDING COLOR, "PRAIRIE

WHEAT"

REMOVE AND DISPOSE OF

EXISTING DOOR AND FRAME.

REPLACE WITH NEW DOOR AND

FRAME, MATCH EXISTING DOOR.

REUSE EXISTING CIPHER LATCH

MECHANISM.

16'

46"

35 1/2"

6' - 6"

PORCH AREA

40"

INSTALL NEW SIDING:

AREA IS READY FOR NEW

SIDING TO BE INSTALLED.

3" WIDE TRIM

No Scale

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

EAST KITCHEN ELEVATION

16"

14"

5'- 3"

26'

7' - 9"

44"

17'- 11"

12"

6"

6"

12"

12"

3" WIDE TRIM AT

ATTIC VENT, PAINT

DARK BROWN

OVEN EXHAUST VENTS

TO BE RETAINED

PAINT EXPOSED PORTION OF BARGE

RAFTER DARK BROWN

EXISTING WASTEWATER

DRAIN, TO BE RETAINED

REMOVE AND DISPOSE

ALL REMAINING EXISTING SIDING.

INSTALL NEW SIDING EAST KITCHEN

ELEVATION

PAINT SIDING TRIM TO MATCH

SIDING COLOR, "PRAIRIE

WHEAT" (Typical)

WHEN SIDING IS REMOVED, REMOVE EXISTING

PLUMBING AND WIRING. INSTALL PLUMBING

AND ELECTRICAL FOR EXISTING STOVES AND

SINKS IN WALL AREA DO NOT DISTURB

INTERIOR SIDE TO REPLACE UTILITIES IN WALL.

NOTE:

PAINT PORCH POSTS, BEAMS,

CEILING AND HANDRAILS AS

TRIM TO MATCH SIDING

COLOR, "PRAIRIE WHEAT"

(Typical)

INSTALL NEW HOSE BIB

IN EXTERIOR WALL

No Scale

3" WIDE TRIM

INSTALL NEW SIDING:

AREA IS READY FOR NEW

SIDING TO BE INSTALLED.

3" WIDE TRIM

RETAIN AND REINSTALL

EXISTING BLDG. PLACARD

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

NORTH KITCHEN ELEVATION

7' - 8"

PAINT WINDOW TRIM DARK

BROWN

WINDOWS TO REMAIN

REPLACE EXISTING SCREENS WITH NEW

PREPARE AND PAINT SIDING

TRIM TO MATCH SIDING

COLOR, "PRAIRIE WHEAT"

(Typical)

16'

8'

INSTALL NEW SIDING 4"

STRIP AT TOP OF WALL

PREPARE AND PAINT EXISTING SIDING

AND TRIM TO MATCH NEW SIDING

COLOR, "PRAIRIE WHEAT" (Typical)

No Scale

3" WIDE TRIM

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

EXTERIOR ELEVATION NORTHEAST

7' - 8"

PAINT WINDOW TRIM DARK

BROWN

WINDOW TO REMAIN

REPLACE EXISTING SCREENS WITH NEW

PREPARE AND PAINT SIDING

TRIM TO MATCH SIDING

COLOR, "PRAIRIE WHEAT"

(Typical)

16'

8'

INSTALL NEW SIDING 4"

STRIP AT TOP OF WALL

PREPARE AND PAINT EXISTING SIDING

AND TRIM TO MATCH NEW SIDING

COLOR, "PRAIRIE WHEAT" (Typical)

No Scale

3" WIDE TRIM

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

ENCLOSED SOFFITS - PLAN VIEW

PREPARE AND PAINT PORCH CEILING,

SOFFITS AND ASSOCIATED TRIM TO

MATCH SIDING COLOR, "PRAIRIE WHEAT"

(Typical).

ENCLOSE PORCH CEILING AFTER

ELECTRICAL CONDUIT AND HARDWARE

IS INSTALLED. DO NOT CUT RAFTERS

TO INSTALL ELECTRICAL FOR PORCH

LIGHTS. USE 1/2 " CDX PLYWOOD FOR

CEILING.

GABLE END YET TO BE ENCLOSED

GABLE END YET TO BE ENCLOSED

GABLE END YET TO BE ENCLOSED

SOFFIT AREAS ENCLOSED NOT YET

FINISHED

SOFFIT AREAS ENCLOSED NOT YET

FINISHED

SOFFIT AREA ENCLOSED NOT YET

FINISHED

PREPARE, SEAL AND PAINT FACE OF

BARGE RAFTER, DARK BROWN

PREPARE, SEAL AND PAINT FACE OF

BARGE RAFTER, DARK BROWN

PREPARE, SEAL AND PAINT FACE OF

BARGE RAFTER, DARK BROWN

PREPARE, SEAL AND PAINT FASCIA

BOARD, DARK BROWN TO MATCH

WINDOW TRIM, ALL THE WAY AROUND

BUILDING (REDWOOD)

FASCIA BOARD

FASCIA BOARD

FASCIA BOARD

FASCIA BOARD

FASCIA BOARD

NOTE:

No Scale

DO NOT PAINT OVER NEW GALVANIZED

STEEL SOFFIT VENTS, SEE SHEET 5 FOR

SOFFIT VENT INSTALLATION LOCATIONS

AND DETAIL.

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Structural Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

EXISTING PROPANE SERVICE LINE

TO FURNACE

EXISTING PLUMBING PLAN VIEW

NO SCALE

EXISTING HOSE BIB AND

WATER LINE

PROVIDE AND INSTALL PIPE HANGERS

WITHIN 12 INCHES OF BOTH SIDES OF

UNION IN EXISTING PROPANE LINE

A/C CONDENSER UNIT

EXISTING WATER LINES ABOVE

CEILING AT WALL.

WATER SUPPLY CONTROL

VALVE

EXISTING WATER SUPPLY RISER

3/4" COPPER LINE

EXISTING 3/4" COPPER WATER SUPPLY

TO HOSE BIB, RECONNECT TO REMAIN

EXISTING HOSE BIB, TO REMAIN

EXISTING WATER SERVICE

TO BATHROOMS.

EXISTING WATER LINES;

SERVICE TO SHOWER

STALLS

EXISTING WATER LINES IN WALLS:

1) NORTHEAST BEDROOM CLOSET WATER SUPPLY LINE TO

EXTERIOR HOSE BIB. COLD WATER; PRESSURE CHECK FOR

LEAKS, IF PASSES PRESSURE TEST RECONNECT TO COLD

WATER ELSE REINSTALL PIPING IN CLOSET WALL.

2) NORTH BATHROOM SHOWERS. PRESSURE CHECK FOR LEAKS,

IF PASSES PRESSURE TEST DETERMINE WHICH ONE IS THE HOT

WATER LINE AND RECONNECT. IF EXISTING PIPING FAILS THE

PRESSURE TEST REINSTALL PIPING. HOT IS LAST TO SUPPLY WHEN

WATER VALVE IN SHOWER STALL IS OPENED.

3) WALL BETWEEN BATHROOMS. THE EXISTING PIPE ON EAST SIDE

IS WHERE WATER IS DELIVERED WHEN THE EXTERIOR SUPPLY

VALVE IS OPENED. IT IS ASSUMED THAT THE WATER LINE ON THE

WEST SIDE IS FOR HOT WATER. PRESSURE CHECK FOR LEAKS IN

EXISTING PIPING IN WALLS. VERIFY WHICH IS THE ACTUAL COLD

WATER SUPPLY AND WHICH IS FOR HOT WATER AND RECONNECT.

4) WALL BETWEEN HOT WATER CLOSET AND UTILITY ROOM.

THE EXISTING 1/2" DIAMETER PIPING ON THE NORTH SIDE IS

ASSUMED TO BE THE HOT WATER SUPPLY FOR THE UTILITY SINK.

THE TWO PIPES ON THE WEST SIDE ARE ASSUMED TO BE THE HOT

WATER SUPPLY TO THE CLOTHES WASHER AND THE COLD WATER

SUPPLY TO BOTH THE CLOTHES WASHER AND THE UTILITY SINK.

PRESSURE TEST THE EXISTING PIPING FOR LEAKS. IF PASSES

PRESSURE CHECK, VERIFY WHICH ONES ARE HOT AND COLD WATER

SUPPLIES AND RECONNECT. IF NOT REINSTALL PIPING IN WALL.

5) PIPING FOR HOT WATER HEATERS IN BACK WALL OF HOT WATER

CLOSET. REMOVE ALL EXISTING PIPING AND VALVES FOR

HOT WATER HEATERS AND INSTALL NEW. EXPAND PIPE CHASE IN

ADJACENT BEDROOM ON NORTH SIDE TO ALLOW FOR BLOWDOWN

PIPING TO BE EXTENDED THROUGH THE WALL FROM THE HOT

WATER HEATER CLOSET TO THE EXTERIOR OF THE BUILDING,

ALL PIPING TO BE INSTALLED SHALL BE 3/4" DIAMETER.

N

REPLACE CONDENSATE PUMP ON FURNACE AND

INSTALL PVC DRAIN PIPING TO EXTERIOR OF BUILDING

VIA EXPANDED PIPE CHASE IN NORTHEAST BEDROOM.

COVER PIPE END WITH MINIMUM

" MESH GALVANIZED

STEEL HARDWARE CLOTH. REPLACE DRYWALL

REMOVED FROM MOLD ABATEMENT. TAPE AND SEAL

JOINTS AND PREPARE FOR PAINTING. CLEAN UP MOLD

STAINED WALLS AND FLOOR AND PAINT/SEAL

CONCRETE WITH GRAY EPOXY FLOOR PAINT TO FINISH

MOLD CLEANUP. WHEN FINISHED AREA PRESENTS AS

"CLEAN AND SERVICEABLE".

EXISTING CONDENSATE PUMP REMOVED

FROM FURNACE AND STORED IN SHOWER

STALL IN BATHROOM #1. EXISTING PVC

VENT PIPING REMOVED FROM FURNACE

AND STORED IN ROOM #3.

Room 1

Room 2

Room 3

Bath 1

Bath 2

Room 5

Room 4

Laundry

Lounge

Kitchen

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Mechanical-Plumbing

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

WATER PIPING PLAN VIEW

NO SCALE

N

EXISTING HOSE BIB AND

WATER LINE TO BE REMOVED

EXISTING WATER LINES ABOVE

CEILING AT WALL.

EXISTING WATER SUPPLY RISER

3/4" COPPER LINE

REMOVE AND REPLACE EXISTING WATER LINES. PROVIDE NEW HOSE BIB AT

EXTERIOR OF WALL. REMOVE EXTERIOR SIDING TO ACCESS AND INSTALL PLUMBING

AND ELECTRICAL FROM ATTIC TO SERVICE LOCATIONS.

INSTALL TWO NEW GOVERNMENT

FURNISHED WATER HEATERS IN EXISTING

ENCLOSURE, SEE DETAILS SHEET 19

EXISTING 3/4" COPPER WATER SUPPLY

TO HOSE BIB, RECONNECT TO REMAIN

EXISTING HOSE BIB, TO REMAIN

EXISTING WATER SERVICE

TO BATHROOMS.

EXISTING WATER LINES;

SERVICE TO SHOWER

STALLS

CW

HW

EXISTING VENT

UTILITY SINK CLOTHES WASHER

EXTEND EXISTING PIPE CHASE

TO WEST BEDROOM WALL, RELOCATE

DUPLEX ELECTRICAL OUTLET TO AREA

ABOVE TOP OF CHASE TO BE EXTENDED.

MATCH FINISH ELEVATION EXISTING CHASE.

EXTEND HOT WATER HEATER BLOWDOWN AND

DRAIN LINES TO EXTERIOR OF BUILDING.

COVER DRAINS SECURELY WITH 1/8" MESH

GALVANIZED STEEL HARDWARE CLOTH FOR

PEST CONTROL

HW CW

WATER SUPPLY CONTROL

VALVE

INSTALL NEW 3/4" COPPER

PIPING, RESTORE SERVICE

INSTALL NEW 3/4" COPPER

PIPING, RESTORE SERVICE

INSTALL NEW 3/4" COPPER

PIPING, RESTORE SERVICE

NOTE: UNHEATED ATTIC SPACE

ALL WATER PIPING INSTALLED AT

LOWEST LEVEL. INTERSECTING

PIPING TO GO ABOVE WATER LINES

AT ALL LOCATIONS.

INSULATE ALL WATER PIPING.

USE FROST KING FOAM PLUMBING

TUBULAR PIPE INSULATION,

R -VALUE 7.1 OR EQUAL.

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Mechanical-Plumbing

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

PIPING AT WATER HEATERS ELEVATION

COLD WATER

HOT WATER

HIGH PRESSURE RELIEF

"BLOWDOWN" DRAIN LINE

3/4" GATE VALVES

GRAVITY DRAIN VALVES

ALL PIPING 3/4" DIAMETER

CW

HW

EXISTING VENT

UTILITY SINK CLOTHES WASHER

3/4 " DIAMETER HIGH PRESSURE RELIEF

"BLOWDOWN" DRAIN LINE. EXTEND TO EXTERIOR

VIA EXTENDED PIPE CHASE IN RM. 4.

COVER OUTLET WITH 1/8" MESH GALVANIZED

STEEL HARDWARE CLOTH TO CONTROL

PESTS ENTERING PIPE.

COLD WATERHOT WATER

WATER SUPPLY

TO KITCHEN

HW

HOT WATER

COLD WATER

HOT WATER

COLD WATER

(WATER SOURCE)

RECONNECT HOT WATER ON LEFT

SIDE AS FACING APPLIANCE/SINK

HOT WATER HEATER ENCLOSURE, REINSTALL

DOOR AND FRAME STORED IN SOUTH HALLWAY

FURNACE

TO NORTH SHOWER STALLS

TO/FROM BATHROOMS

PIPING AT WATER HEATERS PLAN VIEW

NO SCALE

NOTE: UNHEATED ATTIC SPACE

ALL WATER PIPING INSTALLED AT

LOWEST LEVEL. INTERSECTING

PIPING TO GO ABOVE WATER LINES

AT ALL LOCATIONS.

REPAINT WALL AREAS IN WATER HEATER CLOSET

WITH WHITE SEMI-GLOSS INTERIOR HOUSEHOLD

PAINT. SEAL AND PAINT CONCRETE FLOOR WITH

GRAY EPOXY FLOOR PAINT TO FINISH MOLD CLEAN UP.

WHEN FINISHED AREA PRESENTS AS "CLEAN AND

SERVICEABLE".

SEE SHEET 17, "EXISTING WATER

LINES IN WALLS"

HVAC CONDENSATE DRAIN.

EXTEND TO EXTERIOR VIA

EXTENDED PIPE CHASE IN

RM. 4. COVER OUTLET WITH

1/8" MESH GALVANIZED STEEL

HARDWARE CLOTH TO CONTROL

PESTS ENTERING PIPE.

HVAC CONDENSATE PUMP AND

CONDENSATE DRAIN

PVC HVAC CONDENSATE DRAIN

SLOPE TO DRAIN

INSULATE ALL WATER PIPING.

USE FROST KING FOAM PLUMBING

TUBULAR PIPE INSULATION,

R -VALUE 7.1 OR EQUAL.

INSTALL TWO NEW GOVERNMENT FURNISHED

ELECTRIC WATER HEATERS STORED IN THE

KITCHEN IN EXISTING ENCLOSURE.

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Mechanical-Plumbing

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

AIR CONDITIONING EQUIPMENT

EXISTING PROPANE SERVICE LINE

TO FURNACE

REMOVE AND REPLACE

EXISTING CONDENSER UNIT AND

ANY ASSOCIATED REFRIGERANT

PIPING AND ELECTRICAL EQUIPMENT.

A/C CONDENSER UNIT TO BECOME

CONTRACTOR PROPERTY AND

REMOVED FROM GOVERNMENT PROPERTY.

PROVIDE AND INSTALL

NEW 5 TON A/C CONDENSER UNIT

PROVIDE AND INSTALL NEW

5 TON A/C FAN COIL AT TOP

OF FURNACE

INSTALL NEW INSULATED

REFRIGERANT PIPING TO

A/C FAN COIL. USE R-410A

REFRIGERANT FOR NEW

A/C SYSTEM. SUPPORT PIPING,

USE MANUFACTURED

PIPE HANGERS.

N

RM. 1

RM. 2

RM. 3

RM. 4

RM. 5

APPROX. 6 LB OF R-22 REFRIGERANT

RECOVERED FROM EXISTING SYSTEM

IS STORED IN BOTTLE IN RM. 3 IS TO

BECOME CONTRACTOR'S PROPERTY FOR

REUSE IN OTHER LOCATIONS.

EXISTING R-22 5-TON FAN COIL IS REMOVED

FROM THE TOP OF THE FURNACE AND IS

STORED IN RM. 3. FAN COIL TO BECOME

CONTRACTOR PROPERTY TO BE REUSED.

INSTALL PREFABRICATED

PIPE HANGERS 12" EACH SIDE

OF UNION ON EXISTING FUEL

GAS PIPING IN ATTIC OVER

BATHROOM #2. SUPPORT

EXISTING FUEL GAS PIPING.

HVAC = HEATING, VENTILATION, AIR CONDITIONING

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Mechanical-HVAC

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

PROPANE FURNACE: GOODMAN

MODEL #GMH950905DXAB

OUTPUT: 92,000 BTU/HR

MAXIMUM FLOW: 2000 CFM (Nominal)

SPACE WHERE DISTRIBUTION BOX IS TO BE INSTALLED

GALVANIZED STEEL HVAC DUCTWORK RISER,

30" X 20" X 32", CURRENTLY STORED IN RM. 3.

R-22 SYSTEM 5 TON FAN COIL TO BE REPLACED

WITH R-410A SYSTEM, NEW 5 TON FAN COIL.

CONTRACTOR TO SUPPLY ALL MATERIALS, LABOR

AND EQUIPMENT TO MAKE REPAIRS NECESSARY TO

COMMISSION FURNACE/AIR CONDITIONER BACK

INTO SERVICE FULLY FUNCTIONAL

CONTRACTOR TO FABRICATE AND INSTALL NEW

GALVANIZED STEEL DISTRIBUTION BOX (PLENUM) ON TOP

OF EXISTING DUCTWORK RISER. VERIFY MEASUREMENTS

AND ADJUST AS NECESSARY TO CLEAR EXISTING

STRUCTURAL MEMBERS.

DISTRIBUTION BOX -PLENUM

NO SCALE

GALVANIZED STEEL (HVAC)

DUCTWORK RISER, EXISTING.

DUCTWORK RISER IS REMOVED

FROM THE FURNACE AND STORED

IN ROOM 4.

32"

30"

20"

38"

NOTE: ALL MEASUREMENTS SHOWN

ARE NOMINAL. FIELD VERIFY ALL

MEASUREMENTS AND CLEARANCES

FOR FABRICATION AND ASSEMBLY

OF HVAC COMPONENTS.

DISTRIBUTION BOX -PLAN VIEW

NO SCALE

14" DIAMETER

10" DIAMETER

20"

30"

20"

9"

8.5"

19.5"

FABRICATE AND INSTALL

GALVANIZED STEEL (HVAC)

DISTRIBUTION BOX (PLENUM)

FULL DEPTH BAFFLE

2"

10"

8"

2" 14" 14"

2"

2"

EXISTING PROPANE FURNACE

NO SCALE

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Mechanical-HVAC

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

HVAC DUCTWORK LAYOUT

N

Room 1

Room 2Room 3

Room 4

Room 5

Bath 1

Bath 2

Laundry

Lounge

Kitchen

10 " DIAMETER FLEXIBLE DUCT

FROM DISTRIBUTION BOX TO

12" X 12" CEILING OUTLET

REGISTERS IN KITCHEN AS SHOWN

T

12 " DIAMETER FLEXIBLE DUCTS FROM 14"

DIAMETER HALLWAY DUCT INTO 14" X 8"

OUTLET CEILING REGISTERS IN LOUNGE

AREA

12 " DIAMETER FLEXIBLE DUCTS FROM

14" DIAMETER HALLWAY DUCT INTO 12"

X 12" CEILING OUTLET REGISTERS IN

BEDROOMS AND BATHROOMS AS

SHOWN, TYPICAL EXCEPT FOR LOUNGE

AREA.

14 " DIAMETER FLEXIBLE DUCT

FROM DISTRIBUTION BOX OUT TO

HALLWAY TO INDIVIDUAL ROOMS

T = THERMOSTAT LOCATION (EXISTING)

CONTRACTOR TO PROVIDE ALL LABOR,

MATERIAL AND EQUIPMENT TO INSTALL

HVAC DUCTWORK AND CEILING

REGISTERS COMPLETE. SYSTEM SHALL

BE TESTED AND BALANCED PRIOR TO

OCCUPANCY. ALL CEILING REGISTERS

SHALL BE MADE OF STEEL. ALL CEILING

REGISTERS SHALL BE EQUIPPED WITH

ADJUSTABLE DAMPERS.

CUT BACK ROOF DECKING AT EDGE OF LOWER ROOF

TO MAKE ROOM FOR HVAC DUCTWORK

TO PASS THROUGH. DO NOT CUT OR NOTCH TRUSSES.

DUCTWORK IS TO BE INSTALLED ABOVE THE FINISHED CEILING

BETWEEN THE TRUSSES. DO NOT CUT OR MODIFY TRUSSES FOR

INSTALLATION OF DUCTWORK AND

ASSOCIATED HVAC EQUIPMENT.

NEW THERMOSTAT AT SAME LOCATION

14 " DIAMETER IN LINE BALANCING

DAMPER.

T-BRANCH 14-14-14,

14" GALVANIZED STEEL.

14" X 12" X12" WYE

10" X 10" X10" WYE

USE HARD GALVANIZED STEEL

ROUND ADJUSTABLE ELBOWS

FOR 90 DEGREE TURNS, TYPICAL.

14" X 12" X12" WYE

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Mechanical-HVAC

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

N

ELECTRICAL SERVICE

NO SCALE

EXISTING ELECTRICAL

PANEL, TO BE REPLACED

WITH NEW 16 SPACE, 100 AMP

LOAD CENTER FLUSH MOUNTED

IN WALL.

EXISTING ELECTRICAL PANEL IN LAUNDRY ROOM

ELECTRICAL SERVICE

ENTRANCE

CONTRACTOR TO PROVIDE AND INSTALL A NEW METER

BASE AND SERVICE ENTRANCE; (SURFACE MOUNTED).

NEW EQUIPMENT SHALL PROVIDE SERVICE TO TWO NEW

100 AMP RATED LOAD CENTERS (SUBPANELS) AND ONE 50 AMP

AIR CONDITIONING COMPRESSOR UNIT VIA A NEW SAFETY

SWITCH MOUNTED ON EXTERIOR WALL. FOLLOW PG&E

REQUIREMENTS FOR INSTALLING NEW METER BASE AND

SERVICE ENTRANCE.

NEW 16 SPACE, 100 AMP LOAD CENTER

FLUSH MOUNTED IN WALL.

Room 1

Room 2Room 3

Bathroom 1

Bathroom 2

Room 4

Room 5

Lounge

Laundry

Kitchen

EXISTING ELECTRICAL SERVICE ENTRANCE

Porch

ELECTRICAL WIRE

RUNS TO BE CONCEALED

IN ATTIC OR INTERNAL TO

WALLS.

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Electrical Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

Room 1

Room 2

Room 3

Bathroom 1

Bathroom 2

Room 5

Room 4

Laundry

Kitchen

Lounge

N

NEW ELECTRICAL SERVICE

NO SCALE

CONTRACTOR TO PROVIDE AND

INSTALL NEW SURFACE MOUNTED

METER BASE AND SERVICE ENTRANCE.

LOAD CENTER BREAKER SCHEDULE:

MAIN BREAKER

1 & 3) 2 Pole, 100 AMP: Laundry Rm. Load Ctr.

2 & 4) 2 Pole, 100 AMP: Lounge Load Center

5 & 7) 2 Pole, 50 AMP: AC Condenser Unit

CONTRACTOR TO FINISH DEMOLITION OF OLD PANEL AND

ASSOCIATED FEEDER CONDUIT/WIRING AND BRANCH CIRCUIT

WIRING. PROVIDE AND INSTALL NEW CIRCUIT AND NEW 100 AMP

SUB-PANEL TO REPLACE THE EXISTING ELECTRICAL

PANEL IN THE LAUNDRY ROOM.

NEW LOAD CENTER BREAKER SCHEDULE:

LOAD CENTER MAIN CIRCUIT BREAKER

1) 20 AMP: LAUNDRY ROOM (GFCI)

2) 20 AMP: WASHING MACHINE (GFCI)

3) 20 AMP: BATHROOMS (GFCI)

4) 20 AMP: RM. 3 AND OUTLETS

5) 20 AMP: BATHROOMS (GFCI)

6) 20 AMP: LAUNDRY RM. OUTLETS & FURNACE (GFCI)

7) 20 AMP: RM. 4

8) 20 AMP: RM. 4

9 & 11) 2 POLE, 30 AMP: WATER HEATER

10 & 12) 2 POLE, 30 AMP: CLOTHES DRYER

13 & 15) 2 POLE, 30 AMP: WATER HEATER

16) 20 AMP: RM. 5 OUTLETS

CONTRACTOR TO PROVIDE AND INSTALL NEW CIRCUIT

AND NEW 100 AMP SUB-PANEL IN THE LAUNDRY LOUNGE

AREA AT THE LOCATION SHOWN. PROVIDE LOAD CENTER MAIN

CIRCUIT BREAKER.

LOAD SCHEDULE FOR NEW SUB-PANEL:

ROOM / AREA ELECTRICAL LOAD

1 2 Each, 4' LED ceiling lamps

4 Each, duplex outlets, 1 in each wall

1 Each, duplex outlet at rear of T.V. Cabinet

1 Each, duplex outlet in closet at floor level

2 2 Each, 4' LED ceiling lamps

4 Each, duplex outlets, 1 in each wall

1 Each, duplex outlet in closet at floor level

Kitchen 2 Each, 240 VAC service for kitchen ranges

2 Each, Range Ventilation Hoods and Lights

3 Each, 4' LED ceiling lamps

3 Each, LED overhead porch lights

13 Each, duplex outlets - restore existing outlets

(GFCI) protected outlets over countertops

Lounge 3 Each, duplex outlets, 2 in East wall, 1 in South wall

2 Each, 4' LED ceiling lamps

1 Each, Round ceiling LED lamp at kitchen doorway

Hallway 2 Each, duplex outlets, 1 in each wall (So. Hallway)

4 Each, Round ceiling LED lamps.

UTILIZE STRANDED #3 COPPER

CONDUCTORS FOR SUB-PANEL FEEDER

CIRCUITS IN 1.25" EMT.

240V BRANCH CIRCUIT CONDUCTORS

SHALL BE A MINIMUM OF STRANDED #8

COPPER CABLE WITH #6 GROUND.

120V BRANCH CIRCUIT CONDUCTORS

SHALL BE THAT OF ROMEX CABLE, #12/2

WITH GROUND.

3/0 CONDUCTOR FOR SERVICE

CONDUCTOR IN 2" RIGID CONDUIT,

FOLLOW PG&E REQUIREMENTS.

PROVIDE AND INSTALL NEW

GROUNDING ELECTRODE. USE #4

BARE COPPER FOR GROUNDING

CONDUCTOR TO SERVICE PANEL

NEW ELECTRICAL CIRCUIT TO AND

SAFTEY SWITCH FOR AIR

CONDITIONER COMPRESSOR UNIT

CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT AND MATERIALS TO REMOVE AND DISPOSE

OF REMAINING INSTALLED ELECTRICAL WIRING/HARDWARE AND TO INSTALL THE NEW ELECTRIC

SERVICE COMPLETE, REWIRE THE ENTIRE BUILDING. ALL WIRING SHALL BE CONCEALED, EXCEPT

SERVICE ENTRANCE, EITHER IN THE WALLS OR IN THE ATTIC SPACE.

NOTE: GFCI = Ground Fault Circuit Interrupter Equipped Circuit

CONTRACTOR SHALL INSTALL WIRING AND LAMPS WITHOUT CUTTING OR NOTCHING TRUSSES.

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Electrical Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

LIGHTING PLAN

ALL NEW LIGHTING TO BE INSTALLED

SHALL BE LED TYPE LIGHTS AS

SHOWN

Room 1

Room 2

Room 3

Lounge

Laundry

Bathroom 1

Bathroom 2

Room 5

Room 4

Kitchen

Porch

2-LIGHT DUSK TO DAWN

SECURITY LIGHT "BRONZE"

9" DIAMETER OUTDOOR CEILING

LIGHT "BRONZE" ON PORCH AREA

12 " DIAMETER ROUND

FLUSH MOUNT CEILING LIGHT

2 EACH 12 " DIAMETER ROUND

FLUSH MOUNT CEILING LIGHTS

IN LAUNDRY ROOM

16 " DIAMETER ROUND

FLUSH MOUNT CEILING LIGHT

16 " DIAMETER ROUND

FLUSH MOUNT CEILING LIGHTS

16 " DIAMETER ROUND

FLUSH MOUNT CEILING LIGHT

1' LONG VANITY LIGHT

OVER SINK

2' LONG VANITY LIGHT

OVER SINK

4' FLUSH MOUNT CEILING

WHITE WRAPAROUND LIGHTS

4' FLUSH MOUNT CEILING

WHITE WRAPAROUND LIGHTS

4' FLUSH MOUNT CEILING

WHITE WRAPAROUND LIGHTS

4' FLUSH MOUNT CEILING

WHITE WRAPAROUND LIGHTS

4' FLUSH MOUNT CEILING

WHITE WRAPAROUND LIGHTS

4' FLUSH MOUNT CEILING

WHITE WRAPAROUND LIGHTS

4' FLUSH MOUNT CEILING

WHITE WRAPAROUND LIGHTS

SEE SHEETS 26, 27 AND 28 FOR LAMP DETAILS,

SWITCHING LAYOUT AND LIGHTING SCHEDULE

27" LONG "LINAIR" LED 120V BAR LIGHT

OR EQUAL OVER SINK

CONTRACTOR SHALL INSTALL WIRING AND LAMPS WITHOUT CUTTING OR NOTCHING TRUSSES.

REPLACE EXISTING LIGHT BULBS IN RANGE

HOODS WITH LED TYPE BULBS.

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Electrical Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

4' FLUSH MOUNT CEILING WRAPAROUND LIGHT

12" ROUND FLUSH MOUNT CEILING LIGHT

16" ROUND FLUSH MOUNT CEILING LIGHT

2 LIGHT DUSK TO DAWN SECURITY LIGHT BRONZE

VANITY LIGHT OVER SINK

9" ROUND FLUSH MOUNT CEILING PORCH LIGHT

Note: All lights to be installed are Light Emitting Diode (LED) technology.

27" LONG BAR LIGHT OVER KITCHEN SINK

LAMP DETAILS

NO SCALE

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Electrical Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

ELECTRICAL OUTLETS AND LIGHT SWITCHES

S

S

S

= Duplex electrical outlet

= Oven/Dryer electrical outlets

= Single Light Switch

= Double Light Switch

= Triple Light Switch

= Open wall on interior.

(Currently has exposed studs)

S

S

S

Room 1

Room 2

S

S

S

S

S

S

S

S

S

S

S

NEW SWITCH FOR "LINAIR" LED 120V

BAR LIGHT OR EQUAL OVER SINK

REPLACE EXISTING (GFCI) DUPLEX

OUTLETS WITH NEW (GFCI) DUPLEX

OUTLETS IN BOTH BATHROOMS

EXISTING OUTLET UNDER WINDOW

SEE NOTE

EXISTING OUTLET UNDER WINDOW

SEE NOTE.

EXISTING OUTLET UNDER WINDOW

SEE NOTE.

Kitchen

Room 4

Room 5

Laundry

Bathroom 2

Bathroom 1

Room 3

Lounge

Porch

NOTE:

THE THREE LOCATIONS WHERE OUTLETS ARE

UNDER WINDOWS IN FINISHED WALLS. THE

WALLS ARE FINISHED WITH WOOD PANELING

OVER ASSUMED DRYWALL. IF CONTRACTOR

FINDS IT IS NECESSARY TO REMOVE PANELING

AND DRYWALL TO REPLACE WIRING TO

OUTLETS, THAT IS TO SAY THE EXISTING

CONDUCTOR WILL NOT SERVE AS A PULL ROPE

TO INSTALL THE NEW CONDUCTORS TO THE

OUTLETS AS IS THE METHOD EXPECTED TO

REMOVE AND REPLACE THE EXISTING WIRING

IN WALLS THAT ARE FINISHED, THEN THE

WALLS SHALL BE RESTORED BY THE

CONTRACTOR AS IS EXISTING TO INCLUDE

CAREFULLY REMOVING AND REUSING THE

EXISTING WOOD PANELING WITHOUT

DAMAGING THE FINISHED SURFACE OR EDGES

DURING REMOVAL AND RE-INSTALLATION.

ALL SWITCH LOCATIONS ARE EXISTING

EXCEPT BAR LIGHT OVER SINK IN KITCHEN.

OUTLET AND SWITCH BOX COVER PLATES

BROKEN OFF IN AREAS WHERE WALL BOARD

IS REMOVED. REPLACE ALL OUTLET AND

SWITCH COVER PLATES WITH NEW, USE BEIGE

COLOR COVER PLATES FOR OUTLETS

INTERIOR TO THE BUILDING.

SEE LIGHTING SCHEDULE ON SHEET 28

TO DETERMINE WHICH LIGHT SWITCHES

ARE ASSOCIATED TO SPECIFIC LIGHTS

FOR DETERMINING WIRING LAYOUT FOR

BRANCH CIRCUIT INSTALLATIONS.

CONTRACTOR SHALL INSTALL WIRING

SWITCHES, AND LAMPS WITHOUT

NOTCHING OR CUTTING THE

TRUSSES.

INSTALL NEW 120VAC GFCI DUPLEX

OUTLET ON EXTERIOR WALL, USE

EXTERIOR TYPE COVER PLATE THAT

PROTECTS OUTLETS FROM WATER

ENTERING.

EXISTING PIPE CHASE

EXTEND ALL THE WAY

TO WEST WALL

ELEVATE, MOVE, EXISTING OUTLET

ABOVE EXTENDED PIPE CHASE

TO RETAIN OUTLET FOR OCCUPANT

AutoCAD SHX Text

AutoCAD SHX Text As Shown

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text R-5

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Sheet

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text

PACIFIC SOUTHWEST REGION

AutoCAD SHX Text Scale

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text Electrical Repairs

AutoCAD SHX Text Project Name

AutoCAD SHX Text Forest (District-Site)

AutoCAD SHX Text Lassen National Forest

LIGHTING SCHEDULE

ROOM / AREA

SWITCH

ASSOCIATED LIGHTING

KITCHEN

ON RANGE

HOOD #1

PROVIDE NEW POWER SUPPLY, RE-ENERGIZE EXISTING RANGE HOOD,

PROVIDE AND INSTALL LED REPLACEMENT BULB

O…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.