Exhibit8_BradshawRD_OptionComm.pdf

PDF 668 KB Posted

Attached to
Prescott NF Office Consolidation
Solicitation number
12837119R0012
Issued by

About this file

EXHIBIT 8 - BRADSHAW COMM OPTION

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/1 1/1

9 1 3:

R

IC

HA

RD

RP

OL

AN

CO

C

:\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R

P\

PR

ES

CO

TT

D

ET

AI

L\

PR

OJ

EC

TS

\12

R0

2 O

FF

IC

E

CO

NS

OL

ID

AT

IO

N\

1_

PR

ES

OL

IC

IT

AT

IO

N\

RE

VI

SE

D

DR

AW

IN

GS

\P

NF

-C

ON

SO

LI

DA

TI

ON

CO

MM

.D W

G; R3

SOUTHWESTERN REGION

OFFICE

CONSOLIDATION

PRESCOTT

NATIONAL FOREST

BRADSHAW AND CHINO

VALLEY RANGER DISTRICTS

BRADSHAW

COMMUNICATIONS

06/12/2019

R. POLANCO

R. POLANCO

COM-01

001001

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text 1/16"=1'

AutoCAD SHX Text

BRADSHAW BASEMENT PROPOSED FLOORPLAN

AutoCAD SHX Text

AutoCAD SHX Text 1/16"=1'

AutoCAD SHX Text

BRADSHAW MAIN LEVEL PROPOSED FLOORPLAN

AutoCAD SHX Text

SYMBOLS

AutoCAD SHX Text

SHEET NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text SINGLE VOICE/DATA WORKSTATION JACK WITH TWO (2) 4-PAIR CAT 6 CABLES IN A SINGLE GANG ELECTRICAL BOX.

AutoCAD SHX Text DOUBLE VOICE/DATA WORKSTATION JACK WITH FOUR (4) 4-PAIR CAT 6 CABLES IN A SINGLE GANG ELECTRICAL BOX.

AutoCAD SHX Text QUADRUPLE VOICE/DATA WORKSTATION JACK WITH EIGHT (8) 4-PAIR CAT 6 CABLES IN A SINGLE GANG ELECTRICAL BOX.

AutoCAD SHX Text

AutoCAD SHX Text

TELEPHONE JACK, FOR FAX MACHINE

AutoCAD SHX Text

AutoCAD SHX Text

TR

AutoCAD SHX Text

TELECOMMUNICATIONS ROOM

AutoCAD SHX Text

TR

AutoCAD SHX Text

1. LOCATIONS ARE APPROXIMATE. FIELD VERIFY AND MARK FINAL LOCATIONS WITH THE CONTRACTING OFFICE. LOCATIONS MAY VARY LOCATIONS ARE APPROXIMATE. FIELD VERIFY AND MARK FINAL LOCATIONS WITH THE CONTRACTING OFFICE. LOCATIONS MAY VARY SLIGHTLY TO ACCOMMODATE EXISTING LOCATIONS. 2. REMOVE ALL EXISTING CAT CABLING FROM ALL OUTLET LOCATIONS TO THE PANEL IN THE TELECOMMUNICATIONS ROOM. REMOVE ALL EXISTING CAT CABLING FROM ALL OUTLET LOCATIONS TO THE PANEL IN THE TELECOMMUNICATIONS ROOM. 3. REUSE RACEWAYS AND BOXES IF THEY MEET THE REQUIREMENTS IN THE SPECIFICATIONS FOR ADEQUATE SUPPORT DISTRIBUTION OF REUSE RACEWAYS AND BOXES IF THEY MEET THE REQUIREMENTS IN THE SPECIFICATIONS FOR ADEQUATE SUPPORT DISTRIBUTION OF CABLING. 4. REMOVE AND REPLACE ALL EXISTING FACEPLATES WITH NEW, AND RE-LABEL NEW CABLE RUNS AT THE FACEPLATE AND THE PANEL IN REMOVE AND REPLACE ALL EXISTING FACEPLATES WITH NEW, AND RE-LABEL NEW CABLE RUNS AT THE FACEPLATE AND THE PANEL IN THE TELECOMMUNICATIONS ROOM. 5. RUN CAT6 CABLING FROM THE PANEL TO LOCATIONS AS SHOWN IN THE DRAWINGS. RUN CAT6 CABLING FROM THE PANEL TO LOCATIONS AS SHOWN IN THE DRAWINGS. 6. DO NOT REMOVE THE EXISTING TELEPHONE JACK AND WIRING FOR THE FAX MACHINE ON THE FIRST FLOOR. REPLACE FACEPLATE AND DO NOT REMOVE THE EXISTING TELEPHONE JACK AND WIRING FOR THE FAX MACHINE ON THE FIRST FLOOR. REPLACE FACEPLATE AND LABEL ACCORDINGLY.

AutoCAD SHX Text

1. WORK SHALL INCLUDE REPLACING ALL REFERENCES TO CAT5E CABLES AND CONNECTORS ON SHEET WORK SHALL INCLUDE REPLACING ALL REFERENCES TO CAT5E CABLES AND CONNECTORS ON SHEET A-10 WITH CAT6 CABLING, CONNECTORS, AND PORTS FOR THE POP UP POWER DATA STATIONS AND CONFERENCE ROOM COMMUNICATION WORK. IF THIS OPTION IS NOT AWARDED, SHEET A-10 REMAINS AS PART OF THE BASE CONTRACT AND UNCHANGED.

AutoCAD SHX Text

AutoCAD SHX Text SINGLE VOICE/DATA WORKSTATION CONNECTION ONE (1) 4-PAIR CAT 6 CABLE IN A SINGLE GANG ELECTRICAL BOX. CONNECT TO CEILING-MOUNTED PROJECTOR.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text SINGLE VOICE/DATA WORKSTATION CONNECTION ONE (1) 4-PAIR CAT 6 CABLE IN A SINGLE GANG ELECTRICAL BOX, CEILING MOUNTED, FOR WIRELESS ACCESS POINT.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Requirements for CAT6 Installation

Bradshaw Ranger District

06/12/2019

1. Abbreviations

a. TR = Telecommunications Room

b. WAO = Work Area Outlets

2. Raceways

a. General Requirements

i. All conduit installations shall meet NEC and the additional requirements in the BICSI TDM manual;

ii. Be bonded and grounded according to ANSI-J-STD-607-A;

iii. Contain sweeping bends or pull boxes with changes in direction;

iv. And be maximum 100 feet between pull boxes where installed above ground.

b. Conduit

i. EMT conduit, and used for connections from WAO to basket trays.

c. Cable Trays

i. Provided in TR above equipment racks and “T” cross sections to all walls for support of cables to work stations and all external connections.

ii. Extend to perimeter of room and connect to “T” section going to main equipment racks.

iii. Required when main wire distribution system through hallways and large office corridors above suspended ceilings or crawl spaces.

3. Cable Support Hardware

a. Type and interval to protect the cable from damage due to weight of wiring bundles during or after installation, and at minimum:

i. Maximum distance of supports for cables is 18 inches.

ii. Cables form workstations through walls up to wire basket trays shall be in steel raceways.

iii. Supports may include conduits, wire baskets, cable hooks, wire ties and mounting bases, brackets, clips, or other similar devices to provide support or bundling for cables.

iv. J-hooks and D-rings shall be used only for branch runs from main spine cable tray or wire baskets.

v. Supports shall be permanently mounted by screws or other mechanical means. Glue mounted devices are not permitted.

4. Horizontal Cabling

a. Two (2) continuous (no splicing allowed) horizontal cables shall be installed from the Telecommunications Room (TR) to the WAO.

5. Work Area Outlets (WAO)

a. Each WAO shall consist of a minimum two RJ-45 CAT 6, 8-pin modular T 568 A connectors with home run cabling to the Telecommunications Room.

b. Located WAO’s within 3 feet of an electrical outlet and installed at the same height, if possible, as the nearby electrical outlets.

c. Telecommunications box and outlets shall be recessed so that faceplate covers can be flush mounted to the surface

6. Copper Cable Connectors – WAO

a. RJ-45 modular jack color shall be consistent with other plate colors. Icon colors shall be coded to represent the following applications:

i. Voice/data – white, blue

ii. Spare – gray

b. WAO connectors shall be wired to ANSI/EIA/TIA 568 A as shown in Figure 7.1 – Eight Position T568 A Jack Pin/Pair Assignments and per Table 7.2 – T 568 A Color Codes.

7. Copper Cable Terminations

a. Provide minimum 3.3 feet slack for maintenance or re-termination purposes at the TR.

b. Provide minimum 1 foot slack at each telecomm outlet box.

i. Do not coil or stuff in the outlet box or conduit. Leave loose in cavity above or below the wall, freely accessible by gentle pulling from the outlet box.

8. Outlet Box – WAO

a. Wall outlet boxes shall be no smaller than 4-inches wide, 4-inches height, and 3-

1/2 inches deep, and have the capability to accommodate one or more 1-inch conduits.

9. Faceplate Covers – WAO

a. Wall faceplates shall fit the installed outlet box. All cover plates shall have 6 ports, flush mountable, unused ports plugged, flush mountable, with label designations and covers, icons, and dust covers for unused ports.

Sheets and Views
BRD-COMM
PNF-CONSOLIDATION - COMM - 20190610-BRD-COMM.pdf
Sheets and Views
BRD-COMM
PNF-CONSOLIDATION - COMM - 20190610-BRD-COMM.pdf
Sheets and Views
BRD-COMM

File details come from the government source that posted it.