12805B23Q0671 Specifications.pdf
PDF 119 KB Posted
- Solicitation number
- 12805B23Q0671
About this file
This document outlines specifications for a replacement liner for the North Section Reservoir in Bushland, Texas. The solicitation calls for a woven polypropylene liner between 36 to 40 mil thickness sized to fit the reservoir dimensions of approximately 240 by 210 feet. The liner must include two pipe boots of the same material to connect the liner without leakage to the reservoir's 10.75-inch PVC pipe and 14-inch concrete pipe. The related federal contract opportunity is solicitation number 12805B23Q0671 from the Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Plains Area for the replacement liner project located in Bushland, Texas.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attach 02 Schedule of Items 12805B23Q0671.xlsx | XLSX spreadsheet | |
| 12805B23Q0671.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
12805B23Q0671 - Replacement Liner for North Sec�on Reservoir
SPECIFICATIONS:
The total liner dimensions should be sized to fit the reservoir, which is 7 feet deep and measures 227 feet from top of berm to top of berm in one direc�on and 197 feet from top of berm to top of berm in the orthogonal direc�on. This would require a liner size of approximately 240 � by 210 �. This includes an extra foot for the inside slopes (7 � rise and 25 � run), the 6 � width of the top berm, and an extra 5.5 � beyond the outer edge of the top berm to be buried in the ditch around the top of the berm. The two pipe boots should be made of same materials and be sized to fit the two pipes, one of which is 10.75-inch outer diameter PVC and the other of which is approximately 14-inch outside diameter concrete.
Specific Product Specifica�on:
The liner material is to be woven polypropylene of 36 to 40 mil thickness.
In addi�on to the liner material itself, the purchase must include two pipe boots of the same material for connec�ng the liner without leakage to the pipes that connect the reservoir to the irriga�on and pumping systems. One boot should be sized to fit a 10.75-inch outside diameter PVC pipe. The other boot should be sized to fit a 14-inch outside diameter concrete pipe.