1240LT23Q0013.0001 - BRD.CLRD HVAC REPLACEMENT PROJECT.pdf
PDF 1017 KB Posted
- Attached to
- BRD/CLRD HVAC Project Federal contract opportunity
- Solicitation number
- 1240LT23Q0013
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 1240LT23Q0013.0002 - BRD.CLRD HVAC REPLACEMENT.pdf | ||
| J.4 DEFINITION OF BID ITEMS (10 PAGES).pdf | ||
| J.5 SITE MAPS (4 PAGES).pdf | ||
| J.2 WAGE DETERMINATIONS (BOULDER COUNTY) (CO20230017) (02.24.2023) (8 PAGES).pdf | ||
| J.6 EXPERIENCE QUESTIONNAIRE (3 PAGES).pdf | ||
| J.3 STATEMENT OF WORK (6 PAGES).pdf | ||
| J.1 WAGE DETERMINATIONS (LARIMER COUNTY) (CO20230024) (02.24.2023) (7 PAGES).pdf | ||
| 1240LT23Q0013 - BRD.CLRD HVAC Replacement.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(x)
1240LT23Q0013
x x
1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR
OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
40LT
OGDEN UT 84401-2310
324 25TH ST
USDA-FS CSA INTERMOUNTAIN 8
03/14/20230001
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
03/14/2023
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PROJECT TITLE: BRD / CLRD HVAC REPLACEMENT (ARAPAHO-ROOSEVELT NATIONAL FORESTS)
THE PURPOSE OF THIS AMENDMENT IS TO PROVIDE QUESTIONS AND ANSWERS FROM THE SITE VISIT HELD
ON 04/03/2023. DUE DATE REMAINS THE SAME, ALL OTHER TERMS AND CONDITIONS REMAIN.
Period of Performance: 05/15/2023 to 07/17/2023
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
WESTLEY M. BISSON
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
1240LT23Q0013 - BRD / CLRD HVAC Replacement - RFI 002
1. Base Bid / Option A / Option B - Please provide approx. square footage for each building.
Base Bid: North and South Bunkhouses: ~2,500 sq. ft total (or, ~1,250 sq. ft per HVAC unit) Option A: Hot Shot Office: ~1700 sq. ft Option B: Boulder Ranger District Office: ~6,000 sq ft total (or, ~1350 sq. ft for area replacement furnace will service)
2. Scope of work Option B – Can the Owner / USDA-FS confirm the building layout / access to the existing gas furnace is similar to the Ft Collins location?
• Any documentation of the Building Layout / Existing Photos would be appreciated.
Please see attachments for building layout / HVAC location.
• ‘BRO Space’ is an outline of the Boulder Ranger Office, laying out square footage. (Page 3)
• ‘BRO HVAC’ shows what offices/rooms are serviced by what HVAC components. The furnace to be replaced services the offices adjacent to the ‘North Hallway’, comprising of ~1350 sq ft. (Page 4)
• ‘HVACFurnaceReplacementLocation’ shows where the furnace to be replaced is located (in the upstairs storage area, behind locked closet (contractors will have access to this closet)) (Page 5)
3. Is there basement access in bunkhouses to replace copper refrigerant line?
Yes, there is basement access in bunkhouses for any HVAC replacement needs.
4. Is there attic access in the Hot Shot Office for duct work (if awarded)?
Yes, there is attic access in the Hot Shot Office.
3 BRO (BOULDER RANGER OFFICE) HVAC
BRO (BOULDER RANGER OFFICE)SPACE
HVAC FURNACE REPLACEMENT LOCATION5
| 1240LT23Q0013 (11).pdf |
| Binder3.pdf |
| 1240LT23Q0013.0001 - BRD.CLRD HVAC REPLACEMENT PROJECT.pdf |
| Binder1.pdf |
| 1240LT23Q0013 - CLRD_BRD_HVAC Replacement RFI's 002.pdf |
| BRO HVAC |
| BRO space |
HVACFurnaceREplacementLocation.pdf
File details come from the government source that posted it. Updated .