USDA South Building - Room 0410 Data Center Conversion Solicitation # 12314218B0010 DRAWINGS
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 12314218B0010_Amendment___0003_dated_August_15,_2018.pdf | ||
| 12314218B0010_Amendment___0002_dated_August_08,_2018.pdf | ||
| 12314218B0010_Amendment___0001_dated_July_31,_2018.pdf | ||
| USDA_SB_Room_0410_Data_Center_Conversion_â_Sol___12314218B0010_-_SPECS.pdf | ||
| USDA_SB_Room_0410_Data_Center_Conversion_â_Sol___12314218B0010_07.13.2018.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA OF WORK
KEY PLAN
BASEMENT
SOUTH BUILDING ROOM 0410 DATA
CENTER CONVERSION
Addendum #1
DRAWING SHEET INDEX
50% 95% 100%
GENERAL
G 0 01 COVER SHEET X X X
G 0 02 BASEMENT - LIFE SAFETY PLAN - NEW WORK X X X
G 0 03 SUB-BASEMENT PHOTOS X
STRUCTURAL
S 0 01 STRUCTURAL NOTES AND DETAILS X X X
ARCHITECTURAL
A 0 01 ARCHITECTURAL NOTES AND ABBREVIATIONS X X X
AD 1 01 BASEMENT DEMOLITION PLAN X X X
A 1 01 BASEMENT NEW WORK PLAN X X X
A 1 10 BASEMENT REFLECTED CEILING PLAN X X X
A 3 01 SECTIONS X X X
A 4 01 DETAILS X X X
A 7 01 SCHEDULES & TYPICAL DETAILS X X X
FIRE SUPPRESSION
F 0 01
FIRE SUPPRESSION GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS
X X X
FD 1 01 FIRE SUPPRESSION BASEMENT DEMO WORK PLAN X X X
F 1 01 FIRE SUPPRESSION BASEMENT NEW WORK PLAN X X X
F 5 01 FIRE SUPPRESSION FLOW DIAGRAM X X
FIRE ALARM
FA 0 01
FIRE ALARM GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS
X X X
FA 1 01 FIRE ALARM SUB-BASEMENT NEW WORK PLAN X X X
FA 1 02 FIRE ALARM BASEMENT NEW WORK PLAN X X X
FA 5 01 FIRE ALARM RISER DIAGRAM X X
FA 5 02 FIRE ALARM INPUT OUTPUT MATRIX X X
MECHANICAL
M 0 01
LEGEND, ABBREVIATIONS, AND GENERAL NOTES
X X X
M 1 01 SUB-BASEMENT NEW WORK PLAN X X X
M 1 02 BASEMENT NEW WORK PLAN X X X
M 5 01 MECHANICAL DETAILS X X X
M 6 01 MECHANICAL SCHEDULES X X X
M 7 01 MECHANICAL RISER DIAGRAM X X
M 8 01 MECHANICAL CONTROLS X X
M 8 02 MECHANICAL CONTROLS X X
PLUMBING
P 0 01
LEGEND, ABBREVIATIONS, AND GENERAL NOTES
X X X
P 1 02 PLUMBING PLAN - SUBBASEMENT - NEW WORK X X X
P 1 02 PLUMBING PLAN - BASEMENT - NEW WORK X X X
ELECTRICAL
E 0 01
ELECTRICAL NOTES, SYMBOL, AND LEGEND
X X X
E 1 00 ELECTRICAL DEMOLITION PLAN X X
E 1 01 ELECTRICAL NEW WORK LIGHTING PLAN X X X
E 1 02 ELECTRICAL NEW WORK POWER PLAN X X X
E 1 03 ELECTRICAL SUB-BASEMENT NEW WORK POWER PLAN X X X
E 1 04 ELECTRICAL GENERATOR PLAN X X X
E 5 01 ELECTRICAL DETAILS X X X
E 5 02 ELECTRICAL DETAILS X X
E 6 01 ONE LINE DIAGRAM DEMO X X X
E 6 02 ELECTRICAL ONE-LINE DIAGRAM NEW WORK X X X
E 6 03 ELECTRICAL PANEL SCHEDULES X X
AS DM
COVER SHEET
GENERAL
G 0 01
DATE: September 12, 2017
AutoCAD SHX Text
.DWG
AutoCAD SHX Text
CADD FILE
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
NAME
AutoCAD SHX Text
STREET: 14TH & INDEPENDENCE AVE. S.W.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CKD. BY
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SERIES
AutoCAD SHX Text A-E
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
SOLICITATION
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SEQUENCE
AutoCAD SHX Text
CITY: WASHINGTON , DISTRICT OF COLUMBIA
AutoCAD SHX Text
PROGRESS DATE
AutoCAD SHX Text
USDA NUMBER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
SOUTH BUILDING
AutoCAD SHX Text
ROOM 0410
AutoCAD SHX Text
DC0005ZZ
AutoCAD SHX Text
THE DEPARTMENT OF AGRICULTURE
AutoCAD SHX Text
AG-3412-C-16-0008
AutoCAD SHX Text
2017-EB-1
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
ABATEMENT
AutoCAD SHX Text
PLANNING
AutoCAD SHX Text
DATA CENTER CONVERSION
AutoCAD SHX Text
USDA FIRE
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
TELECOM
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
CONTRACTING
AutoCAD SHX Text
OFFICER
AutoCAD SHX Text Ken was here
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AECOM#60535380
AutoCAD SHX Text
HISTORIC
AutoCAD SHX Text
PRESERVATION
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
AECOM TECHNICAL SERVICES, INC.
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
COVER SHT. APPROVALS
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
GSA FIRE
AutoCAD SHX Text
CONCESSIONS
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text 8/08/2017
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 7/21/2017
AutoCAD SHX Text
ADDENDUM 1
AutoCAD SHX Text 9/12/2017
AutoCAD SHX Text
S E
R V
R
R
O O
M
U P
S
R
O O
M
A
E L E
C T
R I C
A L
R
O O
M
A-101
AD-101
T R
A V
L
D
I S
T A
N C
E
ROOM
F E
C
F E
C
F E
C
1 - HR FIRE RESISTANCE RATED FIRE BARRIER WALLS
FEC FIRE EXTINGUISHER IN CABINET LOCATION (CARBON DIOXIDE TYPE
UL-RATED 10-B:C, 15LB, UNLESS NOTED OTHERWISE)
FACP
FIRE ALARM CONTROL PANEL LOCATION
TRAVEL DISTANCE
(FEET)
COMMON PATH OF TRAVEL
(FEET)
APPROVED EXIT / ACCESSIBLE EXIT
DEAD END CORRIDOR
(FEET)
STORAGE USE; # = OCCUPANT LOAD
BUSINESS USE; # = OCCUPANT LOAD
APPLICABLE CODES/STANDARDS
GOVERNMENTAL REGULATIONS:
ADAAG, AMERICAN WITH DISABILITIES ACCESSIBILITIES GUIDELINES (2010)
UFAS, UNIFORM FEDERAL ACCESSIBILITY STANDARDS (2010)
OSHA REGULATION
EPA REGULATIONS
GSA P-100 FACILITIES STANDARDS, 2016
NON-GOVERNMENTAL REGULATIONS:
IBC 2015 (EXCEPT CHAPTER 10, MEANS OF EGRESS)
LIFE SAFETY (EGRESS REQUIREMENTS): LIFE SAFETY CODE (ANSI/NFPA 101, 2015 EDITION)
INTERNATIONAL MECHANICAL CODE, 2009 EDITION
NFPA STANDARDS:
NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2013 EDITION
NFPA 13, STANDARD FOR INSTALLATION OF SPRINKLER SYSTEM, 2016 EDITION
NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2016 EDITION
NFPA 75, STANDARD FOR THE FIRE PROTECTION OF INFORMATION TECHNOLOGY EQUIPMENT, 2017
EDITION
NFPA 101, LIFE SAFETY CODE, 2015 EDITION
OCCUPANCY CLASSIFICATION
THE USDA BUILDING IS A MIXED OCCUPANCY/USE FACILITY CONSISTING OF STORAGE (GROUP S1), ASSEMBLY (GROUP A3), AND BUSINESS (GROUP B) USE GROUPS/OCCUPANCIES PER THE IBC. THE USDA
BUILDING IS CLASSIFIED AS A HIGH-RISE BUILDING PER IBC 403.1 AND NFPA 101 11.8. THE PROJECT AREA
BEING RENOVATED IS CLASSIFIED AS A BUSINESS OCCUPANCY PER IBC.
CONSTRUCTION TYPE
THE EXISTING BUILDING CONSTRUCTION TYPE MOST CLOSELY RESEMBLES TYPE IB PER IBC. NO WORK IN
THIS PROJECT WILL RESULT IN A CHANGE IN THE TYPE OF CONSTRUCTION.
FIRE BARRIER OPENING PROTECTION REQUIREMENTS
IN ACCORDANCE WITH NFPA 75, SECTION 6.1.3.2, THE DATA CENTER SHALL HAVE A FIRE RESISTANCE
RATING OF NOT LESS THAN 1 HOUR. THE UPS ROOM SHALL ALSO HAVE A 1-HOUR FIRE RESISTANCE
RATING IN ACCORDANCE WITH TABLE 509 OF IBC.
THE REQUIREMENTS FOR THE PROTECTION OF FIRE BARRIER OPENINGS ARE BASED UPON APPLICABLE
IBC CRITERIA. IBC CHAPTER 7 GOVERNS THE MATERIALS AND ASSEMBLIES USED FOR STRUCTURAL FIRE
RESISTANCE AND FIRE-RESISTANCE-RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES TO
SAFEGUARD AGAINST THE SPREAD OF FIRE AND SMOKE WITHIN A BUILDING AND THE SPREAD OF FIRE TO
OR FROM BUILDINGS.
GENERAL BUILDING HEIGHTS AND AREAS
THIS PROJECT DOES NOT INVOLVE THE INCREASE OR REDUCTION OF BUILDING
HEIGHTS OR AREAS.
HAZARD CLASSIFICATIONS
SERVER ROOM = B
CORRIDORS = B
UPS AND ATS ROOM = S1
INTERIOR FINISH RATINGS
STORAGE OCCUPANCIES:
- INTERIOR WALL AND CEILING FINISHES: CLASS C MINIMUM (IBC, TABLE 803.11)
- INTERIOR FLOOR FINISHES: NO REQUIREMENT (NFPA 101, 42.3.3.3.2)
BUSINESS OCCUPANCIES:
- INTERIOR WALL AND CEILING FINISHES: CLASS C MINIMUM (IBC, TABLE 803.11)
- INTERIOR FLOOR FINISHES: NO REQUIREMENT (NFPA 101, 39.3.3.3)
MEANS OF EGRESS
EGRESS REQUIREMENTS SHALL BE PER NFPA 101.
OCCUPANT LOAD FACTORS
- BUSINESS: 100 SQFT/PERSON (NFPA 101, TABLE 7.3.1.2)
- STORAGE: 300 SQFT/PERSON
EGRESS CAPACITIES:
- DOORS/CORRIDORS: CLEAR WIDTH / 0.2 INCHES PER PERSON
EXIT ACCESS TRAVEL DISTANCE LIMITS:
- BUSINESS: 200 FT (NFPA 101, SECTION 39.2.6.2)
- STORAGE: 400 FT (NFPA 101, TABLE 42.2.6)
COMMON PATH OF TRAVEL LIMITS:
- BUSINESS: 75 FT (NFPA 101, SECTION 39.2.5.3.3)
- STORAGE: 100 FT (NFPA 101, TABLE 42.2.5)
DEAD END LIMITS:
- BUSINESS: 50 FT (NFPA 101, SECTION 39.2.5.2)
- STORAGE: 100 FT (NFPA 101, TABLE 42.2.5)
ARRANGEMENT OF MEANS OF EGRESS:
EXITS ARE SEPARATED BY AT LEAST ONE-THIRD THE LENGTH OF THE MAXIMUM
DIAGONAL DIMENSION OF THE AREA SERVED PER NFPA 101, 7.5.1.3.3. SEE LIFE SAFETY
PLAN FOR MAXIMUM DIAGONAL AND EXIT SEPARATION MEASUREMENTS.
EXIT ILLUMINATION:
MEANS OF EGRESS WILL BE ILLUMINATED WITH AT LEAST 1 FT-CANDLE MEASURED AT
THE FLOOR IN ACCORDANCE WITH NFPA 101, 7.8.
EMERGENCY LIGHTING AND EXIT SIGNS:
EXIT SIGNS WILL BE PROVIDED TO MARK EXITS AND DIRECT OCCUPANTS TOWARDS
EXITS PER NFPA 101, 7.10. EMERGENCY LIGHTING WILL BE PROVIDED FOR ALL MEANS
OF EGRESS PER NFPA 101, 7.9.
FIRE DEPARTMENT ACCESS
EXISTING FIRE DEPARTMENT ACCESS TO THE BUILDING WILL NOT BE MODIFIED BY THIS PROJECT.
FIRE SUPPRESSION
THIS BUILDING IS NOT FULLY SPRINKLERED; ONLY MODERNIZED AREAS AND A FEW OTHER AREAS
ARE SPRINKLERED. THE AREA OF WORK CONTAINS SPRINKLERS THAT WILL BE MODIFIED TO PROVIDE
COMPLETE PROTECTION OF THE SPACE. THE WET PIPE SYSTEM OUTSIDE OF THE AREA OF WORK
WILL BE MAINTAINED ACTIVE AT ALL TIMES.
CONTRACTOR SHALL COORDINATE WITH GSA FOR APPROVAL OF SHOP DRAWINGS.
FIRE ALARM
THERE ARE CURRENTLY NO FIRE ALARM DEVICES IN THE SPACE. THIS PROJECT INVOLVES THE
ADDITION OF A NEW COMPUTER FIRE ALARM SUB-PANEL, SMOKE DETECTORS, DUCT DETECTORS, AND NOTIFICATION DEVICES. ADDRESSABLE SMOKE DETECTORS UTILIZING EARLY WARNING SMOKE
DETECTION TECHNOLOGY WILL BE USED THROUGHOUT THE SPACE AS WELL AS IN THE RAISED
FLOORS AND ABOVE CEILING SPACE. THE ACTIVATION OF ONE SMOKE DETECTOR SHALL ACTIVATE A
PRE-ALARM SIGNAL AND LOCAL NOTIFICATION APPLIANCES. THE ACTIVATION OF A SECOND SMOKE
DETECTOR SHALL ACTIVATE BUILDING NOTIFICATION APPLIANCES AND DISCONNECT POWER TO THE
INFORMATION TECHNOLOGY EQUIPMENT AND HVAC EQUIPMENT AFTER A PRESET TIME DELAY.
ACTIVATION OF THE WATERFLOW SWITCH ACTIVATE BUILDING NOTIFICATION APPLIANCES,
DISCONNECT POWER TO THE INFORMATION TECHNOLOGY EQUIPMENT AND HVAC EQUIPMENT WITH
NO TIME DELAY, AND CLOSE DAMPERS.
THE NEW COMPUTER FIRE ALARM CONTROL PANEL SHALL BE TIED INTO THE EXISTING W4 CENTRAL
BUILDING FIRE ALARM CONTROL PANEL LOCATED IN ROOM 1041.CONTRACTOR SHALL COORDINATE
WITH GSA FOR TIE-IN TO W4 CENTRAL FIRE ALARM PANEL, APPROVAL OF SHOP DRAWINGS, AND FINAL
AND ACCEPTANCE TESTING.
A-101
AD-101
AREA OF WORK
KEY PLAN
BASEMENT
N
AS DM
LIFE SAFETY PLAN
GENERAL
G 0 02
LIFE SAFETY LEGEND:
SCALE: 3/32"
BASEMENT - LIFE SAFETY PLAN - NEW WORK
00 8' 16'
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
FHC
AutoCAD SHX Text
.DWG
AutoCAD SHX Text
CADD FILE
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
NAME
AutoCAD SHX Text
STREET: 14TH & INDEPENDENCE AVE. S.W.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CKD. BY
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SERIES
AutoCAD SHX Text A-E
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
SOLICITATION
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SEQUENCE
AutoCAD SHX Text
CITY: WASHINGTON , DISTRICT OF COLUMBIA
AutoCAD SHX Text
PROGRESS DATE
AutoCAD SHX Text
USDA NUMBER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
SOUTH BUILDING
AutoCAD SHX Text
ROOM 0410
AutoCAD SHX Text
DC0005ZZ
AutoCAD SHX Text
THE DEPARTMENT OF AGRICULTURE
AutoCAD SHX Text
AG-3412-C-16-0008
AutoCAD SHX Text
2017-EB-1
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
ABATEMENT
AutoCAD SHX Text
PLANNING
AutoCAD SHX Text
DATA CENTER CONVERSION
AutoCAD SHX Text
USDA FIRE
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
TELECOM
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
CONTRACTING
AutoCAD SHX Text
OFFICER
AutoCAD SHX Text Ken was here
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AECOM#60535380
AutoCAD SHX Text
HISTORIC
AutoCAD SHX Text
PRESERVATION
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
AECOM TECHNICAL SERVICES, INC.
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
COVER SHT. APPROVALS
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
GSA FIRE
AutoCAD SHX Text
CONCESSIONS
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text 8/08/2017
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 7/21/2017
AutoCAD SHX Text
ADDENDUM 1
AutoCAD SHX Text 9/12/2017
AutoCAD SHX Text
FIRE AND LIFE SAFETY CODE INFORMATION
N
AS DM
SUB-BASEMENT PHOTOS
GENERAL
G 0 03
GENERAL NOTES:
1. PHOTOS ON THIS SHEET ARE FOR REFERENCE ONLY
TO AID CONTRACTOR IN UNDERSTANDING SPACE
CONSTRAINTS.
PHOTO 1
PHOTO 2
PHOTO 3
PHOTO 4
PHOTO 5A
PHOTO 5B
PHOTO 5CPHOTO 8
PHOTO 7
PHOTO 6
PHOTO 5D
5A
5C
5B
5D
PHOTO LOCATION - SUB-BASEMENT PLAN
SUB-BASEMENT PLAN
AutoCAD SHX Text
RAMP UP
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
MATCH LINE
AutoCAD SHX Text
.DWG
AutoCAD SHX Text
CADD FILE
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
NAME
AutoCAD SHX Text
STREET: 14TH & INDEPENDENCE AVE. S.W.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CKD. BY
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SERIES
AutoCAD SHX Text A-E
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
SOLICITATION
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SEQUENCE
AutoCAD SHX Text
CITY: WASHINGTON , DISTRICT OF COLUMBIA
AutoCAD SHX Text
PROGRESS DATE
AutoCAD SHX Text
USDA NUMBER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
SOUTH BUILDING
AutoCAD SHX Text
ROOM 0410
AutoCAD SHX Text
DC0005ZZ
AutoCAD SHX Text
THE DEPARTMENT OF AGRICULTURE
AutoCAD SHX Text
AG-3412-C-16-0008
AutoCAD SHX Text
2017-EB-1
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
ABATEMENT
AutoCAD SHX Text
PLANNING
AutoCAD SHX Text
DATA CENTER CONVERSION
AutoCAD SHX Text
USDA FIRE
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
TELECOM
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
CONTRACTING
AutoCAD SHX Text
OFFICER
AutoCAD SHX Text Ken was here
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AECOM#60535380
AutoCAD SHX Text
HISTORIC
AutoCAD SHX Text
PRESERVATION
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
AECOM TECHNICAL SERVICES, INC.
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
COVER SHT. APPROVALS
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
GSA FIRE
AutoCAD SHX Text
CONCESSIONS
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text 8/08/2017
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 7/21/2017
AutoCAD SHX Text
ADDENDUM 1
AutoCAD SHX Text 9/12/2017
GENERAL NOTES
CODES AND STANDARDS
1. STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE FOLLOWING CODES:
INTERNATIONAL BUILDING CODE, 2015 EDITION
ACI 318-14
ANSI/AISC 360-10 LRFD, FOURTEENTH EDITION
ASCE 7-10
ACI 530-13
GSA PBS - P100, 2016
DESIGN LOADS AND CRITERIA
1. DESIGN LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
OFFICES (INCLUDING PARTITIONS) 70 PSF
MECHANICAL* 150 PSF
DATA CENTER 150 PSF
CORRIDORS 100 PSF
AREAS NOT OTHERWISE SPECIFIED 100 PSF
*OR EQUIPMENT WEIGHT IF GREATER
2. DESIGN DEAD LOADS:
MEP / CEILING 10 PSF
CMU PARTITIONS ACTUAL WEIGHT
GENERAL
1. THE CONTRACTOR SHALL MEASURE AND PROVIDE ALL EXISTING FIELD DIMENSIONS, ELEVATIONS AND CONDITIONS AT THE JOB SITE PRIOR TO CONSTRUCTION
AND THE SUBMISSION OF SHOP DRAWINGS, AND SHALL NOTIFY THE CONTRACTING OFFICER AND ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES.
VERIFICATION AND NOTIFICATION SHALL PROCEED PRIOR TO THE START OF WORK SO THAT ANY NECESSARY CHANGES CAN BE MADE WITHOUT DELAYING THE
PROJECT SCHEDULE.
2. THE CONTRACTOR SHALL REVIEW AND COORDINATE DIMENSIONS PROVIDED IN THE CONTRACT DOCUMENTS. LAYOUT OF BUILDING FOUNDATIONS AND OTHER
STRUCTURAL MEMBERS SHALL BE BASED ON THE FULL SET OF CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO THE ARCHITECTURAL, CIVIL AND
STRUCTURAL DRAWINGS AND PROJECT SPECIFICATIONS. INCONSISTENCIES OR OMISSIONS IN DIMENSIONS SHALL BE FORWARDED TO THE CONTRACTING
OFFICER FOR REVIEW AND RESOLUTION PRIOR TO PROCEEDING.
3. THE STRUCTURAL DESIGN IS BASED ON THE STRUCTURE IN ITS COMPLETED STATE. THE CONTRACTOR AND HIS SUBS SHALL BE RESPONSIBLE FOR PROVIDING
TEMPORARY BRACING AND SHORING, AS REQUIRED, TO ENSURE VERTICAL AND LATERAL STABILITY OF THE ENTIRE STRUCTURE OR PORTION THEREOF DURING
CONSTRUCTION.
4. DETAILS, SECTIONS, AND NOTES SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR CONDITIONS ELSEWHERE UNLESS
OTHERWISE SHOWN OR NOTED.
5. ANY REQUIRED TEMPORARY SHEETING AND SHORING SHALL BE IN CONFORMANCE WITH OSHA REGULATIONS. UNBRACED EXCAVATIONS SHALL BE SLOPED NO
GREATER THAN (1.5) HORIZONTAL TO (1) VERTICAL.
6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO RETAIN THE SERVICES OF A REGISTERED STRUCTURAL ENGINEER TO DETERMINE THE ALLOWABLE TEMPORARY
CONSTRUCTION LOADS AND TO PROVIDE A DESIGN FOR ALL FORMWORK, FORMWORK, STAGING, BRACING, SHEETING AND SHORING WHENEVER THE LOADING
FROM THE CONTRACTOR'S WORK EXCEEDS THE ALLOWABLE LIVE LOAD CAPACITIES OF THE EXISTING STRUCTURE.
7. CONTRACTOR SHALL LOCATE ALL UNDERGROUND UTILITIES IN VICINITY OF FOUNDATIONS AND DETERMINE IF A CONFLICT EXISTS. CONTRACTOR SHALL ALSO
PROVIDE INFORMATION ON LOCATION SIZE AND ELEVATION OF UTILITIES PRIOR TO START OF WORK SO THAT ANY NECESSARY CHANGES CAN BE MADE WITHOUT
DELAYING THE PROJECT SCHEDULE.
8. THE DEVELOPMENT AND IMPLEMENTATION OF JOB SITE SAFETY AND CONSTRUCTION PROCEDURES ARE SOLELY THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR.
9. WHERE CONFLICTS EXISTS AMONG THE VARIOUS PARTS OF THE STRUCTURAL CONTRACT DOCUMENTS, STRUCTURAL DRAWINGS, GENERAL NOTES, AND
SPECIFICATION, THE STRICTEST REQUIREMENT, AS INDICATED BY THE ENGINEER, SHALL GOVERN.
CONCRETE
1. ALL CONCRETE SHALL BE NORMAL WEIGHT 145 PCF WET CONCRETE DENSITY (UNLESS OTHERWISE NOTED) AND SHALL BE SUBMITTED TO THE ENGINEER FOR
APPROVAL BEFORE USE, WITH COMPRESSIVE STRENGTH AS FOLLOWS:
STRUCTURAL SLABS f'c = 4000 PSI (AIR ENTRAINED @ EXTERIOR SLABS)
ALL OTHER CONCRETE NOT OTHERWISE INDICATED f'c = 4000 PSI
2. CURING COMPOUND MUST BE APPLIED IMMEDIATELY FOLLOWING FINAL FINISHING.
3. CALCIUM CHLORIDE SHALL NOT BE PERMITTED IN CONCRETE.
4. PROVIDE CONTROL JOINTS AT [25] FEET O.C. MAX. LOCATE CONTROL JOINTS TO FORM APPROXIMATE SQUARE PANELS WITH THE LENGTH OF ONE SIDE NOT
EXCEEDING THE ADJACENT SIDE BY A FACTOR OF 1.5. CONTROL JOINTS MAY BE CONTRACTION JOINTS, CONSTRUCTION JOINTS, OR EXPANSION JOINTS.
5. CHAMFER EDGES OF PERMANENTLY EXPOSED CONCRETE SURFACES 3/4-INCH, UNO.
6. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR LOCATIONS OF OPENINGS AND SLEEVES IN CONCRETE WALLS AND SUPPORTED FLOORS. SPREAD
REINFORCEMENT AT OPENINGS AND SLEEVES UNLESS OTHERWISE SHOWN. DO NOT CUT REINFORCEMENT. SEE TYPICAL REINFORCEMENT DETAILS FOR
OPENINGS IN SLABS AND WALLS FOR ADDITIONAL REQUIREMENTS.
7. ALL PLUMBING SLOTS AROUND SLEEVES SHALL BE FILLED WITH FIRE RATED MATERIAL WITH AN EQUIVALENT RATING OF THE ADJACENT FLOOR CONSTRUCTION.
8. CONDUITS IN CONCRETE SLABS SHALL BE SPACED SUCH THAT THE CENTER TO CENTER DISTANCE BETWEEN CONDUITS IS A MINIMUM OF THREE TIMES THE
OUTSIDE DIAMETER OF THE LARGEST CONDUIT.
9. CONDUIT HAVING OUTSIDE DIAMETER LARGER THAN ONE THIRD OF THE SLAB THICKNESS SHALL NOT BE PERMITTED. CONDUITS THAT CROSS EACH OTHER IN
SLAB SHALL NOT CONSUME AT POINT OF INTERSECTION MORE THAN ONE THIRD OF THE SLAB THICKNESS.
10. ALL PIPE SLEEVES THROUGH WALLS AND SLABS SHALL BE SCHEDULE 40 STEEL PIPE.
11. ALUMINUM CONDUITS ARE NOT PERMITTED IN CONCRETE ELEMENTS.
12. ALL MAINTENANCE OF CONCRETE WORK SHALL BE IN ACCORDANCE WITH SECTION 030130 "MAINTENANCE OF CAST-IN-PLACE CONCRETE".
13. THE FOLLOWING ALLOWANCES ARE ESTIMATED QUANTITIES FOR EACH REPAIR ITEM:
A) REMOVAL OF DETERIORATED CONCERTE AND SUBSEQUENT REPLACEMENT AND PATCHING - 100 SQUARE FEET.
B) FLOOR JOINT REPAIR - 40 LINEAR FEET.
C) EPOXY CRACK INJECTION - 200 LINEAR FEET.
D) CORROSION-INHIBITING TREATMENT - 1300 SQUARE FEET.
E ) POLYMER SEALERS - 500 SQUARE FEET.
14. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE GOVERNMENT'S REPRESENTATIVE IF ANY EXISTING CONDITIONS IN THE FIELD CAUSE THE ESTIMATED
ALLOWANCES PROVIDED FOR EACH ITEM TO BE EXCEEDED.
REINFORCING STEEL
1. REINFORCING BARS
ASTM A 615 GRADE 60 (NEW BILLET STEEL), DEFORMED Fy = 60 KSI
2. REINFORCEMENT SHALL BE DETAILED, FABRICATED, AND PLACED IN ACCORDANCE WITH SP-66 (LATEST EDITION).
3. CONTINUOUS REINFORCING IN WALLS AND SLABS MAY BE SPLICED, AS REQUIRED, PROVIDING BARS ARE OF THE LONGEST PRACTICABLE LENGTH AND SPLICES
ARE SHOWN ON REINFORCING SHOP DRAWINGS. WHEREVER POSSIBLE, SPLICES SHALL BE STAGGERED. FIELD CUTTING OF REINFORCEMENT WILL NOT BE
PERMITTED
4. UNLESS OTHERWISE SHOWN, BARS AT WALL AND CONTINUOUS FOOTING CORNERS AND INTERSECTIONS SHALL BE DETAILED AS SHOWN IN SP-66. CORNER BARS
SHALL BE DETAILED AS SHOWN FOR OUTSIDE LOADED CORNERS. INTERSECTIONS SHALL BE DETAILED WITHOUT DIAGONAL BARS.
5. PROVIDE CONCRETE COVER FOR REINFORCING AS SPECIFIED IN SP-66 AND AS LISTED BELOW, UNLESS OTHERWISE INDICATED ON THE STRUCTURAL DRAWINGS.
SECURELY PLACE REINFORCEMENT TO PREVENT DISPLACEMENT DURING CONCRETE PLACEMENT.
CAST AGAINST EARTH 3"
EXPOSED TO EARTH OR WEATHER:
#5 AND SMALLER BARS AND WWF 1-1/2" (U.N.O.)
#6 AND LARGER BARS 2"
CAST AGAINST EARTH 3"
EXPOSED TO EARTH OR WEATHER:
#5 AND SMALLER BARS AND WWF 1-1/2" (U.N.O.)
#6 AND LARGER BARS 2"
NOT EXPOSED TO EARTH OR WEATHER:
SLABS AND WALLS:
#11 AND SMALLER AND WWF 3/4"
#14 AND LARGER BARS 1-1/2"
BEAMS AND COLUMNS 1-1/2"
SLAB SUBJECT TO VEHICULAR TRAFFIC:
FRAMED SLABS TOP COVER 2"
BOTTOM COVER 3/4"
1. PROVIDE DOWELS TO MATCH REINFORCEMENT SIZE AND SPACING INDICATED FOR ALL STRUCTURAL ELEMENTS, UNLESS OTHERWISE INDICATED.
2. REINFORCE FLOOR SLABS ON GRADE IN ACCORDANCE WITH THE FOLLOWING SCHEDULE, UNLESS OTHERWISE NOTED. PLACE REINFORCEMENT 2 INCHES BELOW
TOP OF SLAB UNLESS OTHERWISE NOTED.
SLAB THICKNESS REINFORCEMENT
4" 6X6_W2.0XW2.0 WWR
5" 6X6_W2.9XW2.9 WWR
6" 6X6_W2.9XW2.9 WWR
8" #3@12 EW, TOP
3. IN SLABS-ON-GRADE, PROVIDE 2- #4X4'-0" DIAGONAL BARS IN THE MIDDLE OF THE SLAB AT EACH CORNER OF OPENINGS OVER 1'-0" SQUARE AND AT RE-ENTRANT
CORNERS.
4. WHERE CONSTRUCTION JOINTS ARE PROVIDED, THE REINFORCEMENT SHALL PASS CONTINUOUSLY THROUGH THE JOINT.
5. WELDED-WIRE REINFORCEMENT SHALL HAVE ENDS LAPPED ONE FULL PANEL.
6. ANY MECHANICAL SPLICES USED MUST BE "TENSION-COMPRESSION" TYPE AND SHALL COMPLY WITH ACI-318 12.14.3 UNLESS OTHERWISE SPECIFICALLY
APPROVED BY THE STRUCTURAL ENGINEER. SHOP DRAWINGS SUBMITTED FOR ENGINEERS APPROVAL MUST INDICATE THE USE AND TYPE OF ANY MECHANICAL
SPLICES USED. SPLICE MUST DEVELOP 125% OF THE STRENGTH OF BAR IN TENSION.
7. DEVELOPMENT AND SPLICE LENGTHS ARE IN TENSION UNLESS OTHERWISE INDICATED. DEVELOPMENT AND LAP SPLICE LENGTH SHALL BE CALCULATED
ACCORDING TO ACI-318 CHAPTER 12 OR USE BELOW:
A. DEVELOPMENT LENGTH FOR DEFORMED BARS IN COMPRESSION: ℓdc = 22d
B. DEVELOPMENT LENGTH FOR DEFORMED BARS IN TENSION:
INCREASE LENGTH 30% FOR LIGHT WEIGHT CONCRETE
INCREASE LENGTH 50% FOR EPOXY COATED REINF
LAP SPLICE LENGTHS FOR CLASS A SPLICES = 1.0 ℓd
LAP SPLICE LENGTHS FOR CLASS B SPLICES = 1.3 ℓd
POST-INSTALLED EXPANSION AND EPOXY ANCHORS
1. ALL MECHANICAL AND EPOXY ANCHORS SHOWN IN THE STRUCTURAL DOCUMENTS SHALL BE MANUFACTURED BY HILTI, POWERS, OR AN APPROVED EQUIVALENT.
ANCHOR TECHNICAL INFORMATION SHALL BE SUBMITTED TO THE CONTRACTING OFFICER AND THE STRUCTURAL ENGINEER OF RECORD FOR REVIEW.
SUBMITTAL SHALL CONTAIN ALL APPLICABLE TECHNICAL INFORMATION INCLUDING ALLOWABLE LOAD VALUES, MANUFACTURER RECOMMENDED INSTALLATION
PROCEDURES, ETC. ANCHORS WERE ASSUMED TO HAVE THE FOLLOWING PROPERTIES U.N.O. ON THE DRAWINGS:
A. EPOXY ANCHORS - HILTI-RE 500-SD W/ THREADED ROD
MIN. EMBEDMENT DEPTH = 3-1/2"
MIN. EDGE DISTANCE = 4"
B. EXPANSION ANCHORS - HILTI KWIK BOLT TZ
MIN. EMBEDMENT DEPTH = 4"
MIN. EDGE DISTANCE = 6"
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ANCHOR LOCATIONS AT ALL PERIMETER MASONRY WALLS. MASONRY WALL CELLS SHALL BE
GROUTED SOLID AT ALL ANCHOR LOCATIONS FOR A MINIMUM 12" IN ALL DIRECTIONS FROM ANCHOR PENETRATION POINT.
3. ALL ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
4. MECHANICAL ANCHOR TYPE HAS BEEN SELECTED TO CONFORM TO THE REQUIREMENTS OF APPENDIX D OF ACI 318-[05]. EQUIVALENT ANCHORS SUBMITTED BY
THE CONTRACTOR SHALL MEET THE QUALIFICATION REQUIREMENTS OF ACI 355.2-04 "QUALIFICATION OF POST-INSTALLED MECHANICAL ANCHORS IN CONCRETE."
RENOVATION AND EXISTING STRUCTURES
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, ETC., NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW PORTIONS
OF THE STRUCTURE TO THE EXISTING STRUCTURE. THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS NECESSARY FOR PROPER FABRICATION AND
ERECTION OF ALL STRUCTURAL MEMBERS.
2. BEFORE PROCEEDING WITH ANY WORK WITHIN OR ADJACENT TO THE EXISTING STRUCTURE, THE CONTRACTOR SHALL BECOME FAMILIAR WITH EXISTING
CONDITIONS. DURING THE PROCESS OF CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE INTEGRITY OF THE EXISTING
STRUCTURE WHERE THE EXISTING STRUCTURE IS MODIFIED TO ACCOMMODATE NEW CONSTRUCTION AND TO PROTECT FROM DAMAGE THOSE PORTIONS OF THE
EXISTING STRUCTURE, WHICH ARE TO REMAIN.
3. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE (COR) OF ANY EXISTING CONDITIONS THAT DIFFER FROM THOSE INDICATED
ON THE DRAWINGS.
4. IF CONCRETE DETERIORATION SUCH AS SPALLING OR EXPOSED REBAR IS OBSERVED, THEN REPAIR PER SPECIFICATIONS AND TYPICAL DETAILS PRIOR TO
INSTALLING NEW WORK, NOTE IS APPLICABLE TO ALL AREAS WITHIN LIMITS OF WORK.
5. PRIOR TO ANY CORING OF CONCRETE SLABS, USE NON-DESTRUCTIVE METHODS, SUCH AS GPR, TO LOCATE REBAR IN EXISTING SLAB. AVOID CUTTING OR
DAMAGING EXISTING REBAR.
TYPICAL EQUIPMENT PAD MODIFICATION
AutoCAD SHX Text
SLAB THK
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text NOTE: COORD SIZE, QTY, & LOC OF EQUIP BOLTS AND PAD WITH EQUIP SUPPLIER'S CERT DWG. SEE ARCH, MECH, AND ELEC DWG FOR LOCATION AND SIZE OF EQUIP PADS.
AutoCAD SHX Text
(E) 6 " CONC PAD12" CONC PAD
AutoCAD SHX Text
T/ EXISTING TOPPING SLAB
AutoCAD SHX Text
(N) 3" RIGID INSULATION, MATCH EXISTING INSULATION
AutoCAD SHX Text
(E) WEARING SURFACE TOPPING SLAB
AutoCAD SHX Text
(N) 6x6-W2.9x2.9WWR
AutoCAD SHX Text
3" (E) INSULATION
AutoCAD SHX Text
EXISTING CONC PAD
AutoCAD SHX Text
(N) CONC PAD, MATCH EXISTING THICKNESS
AutoCAD SHX Text
(N) 2 #4
AutoCAD SHX Text
(N) #4 @ 12" O.C. DOWELS, DRILL AND GROUT INTO EXISTING CONC
AutoCAD SHX Text
T/ EXISTING SLAB
AutoCAD SHX Text
.DWG
AutoCAD SHX Text
CADD FILE
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
NAME
AutoCAD SHX Text
STREET: 14TH & INDEPENDENCE AVE. S.W.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CKD. BY
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SERIES
AutoCAD SHX Text A-E
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
SOLICITATION
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SEQUENCE
AutoCAD SHX Text
CITY: WASHINGTON , DISTRICT OF COLUMBIA
AutoCAD SHX Text
PROGRESS DATE
AutoCAD SHX Text
USDA NUMBER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
SOUTH BUILDING
AutoCAD SHX Text
ROOM 0410
AutoCAD SHX Text
DC0005ZZ
AutoCAD SHX Text
THE DEPARTMENT OF AGRICULTURE
AutoCAD SHX Text
AG-3412-C-16-0008
AutoCAD SHX Text
2017-EB-1
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
ABATEMENT
AutoCAD SHX Text
PLANNING
AutoCAD SHX Text
DATA CENTER CONVERSION
AutoCAD SHX Text
USDA FIRE
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
TELECOM
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
CONTRACTING
AutoCAD SHX Text
OFFICER
AutoCAD SHX Text Ken was here
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AECOM#60535380
AutoCAD SHX Text
HISTORIC
AutoCAD SHX Text
PRESERVATION
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
AECOM TECHNICAL SERVICES, INC.
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
COVER SHT. APPROVALS
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
GSA FIRE
AutoCAD SHX Text
CONCESSIONS
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text 8/08/2017
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 7/21/2017
AutoCAD SHX Text
ADDENDUM 1
AutoCAD SHX Text 9/12/2017
AutoCAD SHX Text
AutoCAD SHX Text
STRUCTURAL NOTES AND DETAILS
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
BASEMENT
AS DM
ARCHITECTURAL NOTES &
ABBREVIATIONS
ARCHITECTURE
A 0 01
DETAIL
SCALE
A-301
6'-2 1/4"
1'-2 3/16"
7'-3 1/2" 6'-2 1/4"
10 1/2"
9'-11"
EXISTING CONCRETE PAD TO REMAIN
TEMPORARILY REMOVE
EXISTING BOLLARDS (TYP)
REMOVE EXISTING GENERATOR
SAW CUT AND REMOVE PORTION OF EXISTING
TOPPING SLAB
25'-0" 25'-0"
50'-0"
A-401
AREA OF WORK
KEY PLAN
BASEMENT
N
1/4" = 1'-0
4' 8'
GENERAL DEMO NOTES
1. REFER TO DRAWING A-001 FOR GENERAL NOTES.
2. WALLS AND OTHER ITEMS TO BE REMOVED ARE SHOWN
DASHED ON THE DEMO PLANS.
3. SEE SPECIFIC DEMOLITION NOTES FOR DEMOLITION INFORMATION
THAT PERTAINS TO SPECIFICALLY DESIGNED AREAS.
(DENOTED AS THUS: ON THE DEMOLITION PLANS).
4. WHERE EXISTING DOORS ARE SCHEDULED TO BE REMOVED,
REMOVE DOOR, FRAME AND HARDWARE. COORDINATE
THE SALVAGE OF THESE ITEMS WITH THE OWNER.
5. ALL REQUIRED DEMOLITION WORK FOR MECHANICAL (HVAC &
PLUMBING) AND ELECTRICAL SERVICES ARE NOT SPECIFICALLY
SHOWN ON THE DEMOLITION DRAWINGS. THESE ITEMS ARE TO BE
IDENTIFIED AND COORDINATED WITH THE APPLICABLE TRADE(S).
6. CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS
IN THE FIELD PRIOR TO UNDERTAKING ANY DEMOLITION
WORK. ANY DISCREPANCIES SHOULD BE BROUGHT TO THE
OWNER'S ATTENTION IMMEDIATELY. ASBESTOS INSULATION ON
ABANDONED PIPING RISERS MAY BE FOUND INSIDE CHASE. PROVIDE
ASBESTOS ABATEMENT AS REQUIRED.
7. WHERE EXISTING WALL, CEILING, OR FLOOR ARE TO REMAIN
AND ARE DISTURBED BY DEMOLITION AND/OR
CONSTRUCTION, THEY SHALL BE REPAIRED AS REQUIRED
TO MATCH ORIGINAL INTEGRITY AND ADJACENT
CONSTRUCTION.
8. PROVIDE TEMPORARY DUST PARTITION AND PROTECTED
ACCESS ENCLOSURES WHERE NOTED OR DIRECTED BY
OWNER AROUND ALL AREAS OF WORK TO PREVENT THE
SPREAD OF CONSTRUCTION DEBRIS OR DUST.
9. REMOVE ALL EXISTING FLOOR FINISHES (INCLUDING
MASTICS AND ADHESIVES) IN AREAS WHERE NEW FLOOR FINISHES
ARE SCHEDULED OR DETAILED. CONTRACTOR SHALL PREPARE
SURFACES AS REQUIRED FOR NEW FLOOR FINISHES AS
SCHEDULED. SEE FINISH SCHEDULE FOR NEW FLOOR FINISHES.
10. REMOVE ALL EXISTING BASE MATERIAL IN AREAS WHERE
NEW BASE MATERIAL IS SCHEDULED. SEE FINISH SCHEDULE
FOR NEW BASE MATERIALS.
11. REMOVE ALL EXISTING WALL FINISHES (INCLUDING MASTICS
AND ADHESIVES) IN AREAS WHERE NEW WALL FINISHES ARE
SCHEDULED OR DETAILED. PREPARE SURFACES AS REQUIRED
FOR NEW WALL FINISHES AS SCHEDULED. SEE FINISH
SCHEDULE FOR NEW WALL FINISHES.
12. ALL EXISTING WALLS, CEILING, FLOORING, ETC. WHICH ARE
DAMAGED DUE TO DEMOLITION WORK SHALL BE PATCHED
(REGARDLESS OF SIZE) TO MATCH EXISTING AND/OR NEW
FINISHES SCHEDULED.
13. ALL FLOOR, WALL, AND CEILING MOUNTED EQUIPMENT WITHIN
THE CONTRACT DEMOLITION AREAS IS TO BE REMOVED. U.N.O.
COORDINATE SALVAGE OF EXISTING EQUIPMENT WITH THE
OWNER BEFORE REMOVAL FROM THE SITE. SEE EQUIPMENT
LIST FOR FURTHER INFORMATION.
14. ANY DEMOLITION WORK NECESSARY ON FLOOR BELOW OR
BELOW (DEMO OR REQUIRED TO INSTALL NEW WORK) SHALL BE
SCHEDULED WITH THE OWNER. ANY FINISHES DISTURBED
OR DAMAGED SHOULD BE PATCHED OR REPLACED TO
MATCH EXISTING.
15. THE REQUIRED DEMOLITION SHALL NOT BE LIMITED TO
THAT PORTION SHOWN ON THE PLANS ALONE. WORK
COINCIDENTAL THERE TO WHICH IS NECESSARY TO
ACCOMPLISH THE INTENT OF THE CONTRACT DOCUMENTS
IS ALSO PART OF WORK.
16. THE CONTRACTOR SHALL SCHEDULE ALL WORK, INCLUDING
ANY INTERRUPTION OF UTILITIES PRIOR TO STARTING
WORK. THE BUILDING SHALL BE OCCUPIED AND IN USE
DURING THE TIME THE WORK IS BEING PERFORMED.
CONTRACTOR MUST NOTIFY/SCHEDULE INTERRUPTIONS
WITH OWNER'S APPROVAL.
17. PRIOR TO STARTING DEMOLITION WORK THE CONTRACTOR
SHALL MEET WITH THE OWNER TO COORDINATE ALL ITEMS
TO BE SALVAGED AND/OR RELOCATED. ALL SALVAGED
ITEMS MUST BE REMOVED TO AVOID DAMAGE, PROTECTED
AND STORED IN A LOCATION DIRECTED BY THE OWNER.
18. REFER TO OTHER DISCIPLINE (MECHANICAL, ELECTRICAL,
PLUMBING) DEMOLITION PLANS FOR ADDITIONAL ITEMS TO BE
REMOVED. PATCH AND REPAIR ALL FINISHES AND DEVICES
DISTURBED BY DEMOLITION WORK.
19. PATCH HOLES AND VOIDS (REGARDLESS OF SIZE) IN EXISTING
CONCRETE FLOORS OCCURRING AS A RESULT OF DEMOLITION OR
CONSTRUCTION. MATCH THICKNESS OF EXISTING CONCRETE.
20. PROTECT ALL FINISHES SCHEDULED TO REMAIN AS REQUIRED TO
MAINTAIN THEIR INTEGRITY.
21. REMOVE ALL MISCELLANEOUS STEEL SUPPORTS FOR EXISTING
CEILING OR WALL MOUNTED EQUIPMENT TO BE REMOVED OR
RELOCATED.
22. COORDINATE REMOVAL OF DEBRIS FROM PROJECT SITE WITH
OWNER.
23. EXISTING PARTITIONS THAT ARE INDICATED TO BE REMOVED
SHALL BE REMOVED TO THEIR FULLEST HEIGHT U.N.O.
24. COORDINATE ALL DEMOLITION WITH ABATEMENT WORK PRIOR TO
STARTING DEMOLITION.
25. REMOVE ALL MISCELLANEOUS WALL MOUNTED CLIPS & BRACKETS.
26. CUT & CAP ALL EXISTING ABANDONED IN PLACE PIPES EXTENDING
THROUGH WALL TO ALLOW FOR NEW WALL CONSTRUCTION.
27. REMOVE ALL LOOSE OR DETERIORATING PLASTER & LATH TO
ALLOW FOR NEW WALL CONSTRUCTION.
DEMO SYMBOLS
EXISTING
PARTITION
TO BE REMOVED
EXISTING
PARTITION TO
REMAIN
EXISTING DOOR
TO REMAIN
EXISTING DOOR
TO BE REMOVED
SCOPE OF WORK
REMOVE EXISTING DOOR & FRAME.
DEMOLISH PORTION OF EXISTING WALL, EXTENTS
TO PROVIDE FOR NEW PARTITIONS & DOORS AS
SHOWN ON THE NEW WORK PLAN.
WINDOWS ABOVE TO REMAIN, REMOVE EXISTING
SILL AND METAL BRACKETS BELOW SILL.
REMOVE EXISTING CEILING, LIGHTS, AND CARPET.
REMOVE EXISTING HEATING UNIT BELOW WINDOW
SILL. REMOVE 5" AIR DUCT (2)
" COPPER PIPES,
AND COPPER AIRLINE TO RISERS INSIDE THE
ADJACENT CHASE. CAP ALL ASSOCIATED
OPENINGS AT RISERS.
DEMOLISH WALL TO 2" BELOW EXISTING FINISHED
CORRIDOR FLOOR.
REMOVE PEELING PAINT, IF ANY, AT CEILING SLAB.
DEMO CODED NOTES
AS DM
BASEMENT DEMO PLAN
ARCHITECTURE
AD 1 01
SCALE: 1/4" SCALE
BASEMENT DEMO PLAN
SCALE: 1/4" SCALE
EXTERIOR GENERATOR PAD DEMO PLAN
50'-0"
8'-6" 8'-6" 8'-6" 8'-6" 8'-6"
1'-7"
7"
EXISTING CONCRETE EQUIPMENT PAD
NEW CONCRETE
EQUIPMENT PAD
NEW BOLLARDS TO
MATCH EXISTING (TYP)
A-401
0410A.10410.10410.20418.1
0418.3
0418.2
0410.3 0410.4
A-301
A-301
E Q
E Q
A-411
3'-7 5/8" 2'-2 1/2" 3'-6 5/8" 2'-3 1/8"
EQ
EQ
4'-6 3/8" 4'-4"
8"
2'-6 1/2" 2'-0" 3'-4"
1'-5 5/16"
4" 6'-4" 4" 4'-11 1/4" 3'-4"
4"
ALIGN WITH EXISTING
CONC. FLOOR EDGE
1'-1 5/8"
4"
2'-0"
TYP.
PATCH, REPAIR, & PAINT TO MATCH EXISTING CORRIDOR FINISH
A-401
2'-0 5/8"
78'-6 1/4"
14'-0" 10'-4" 9'-7" 9'-8" 9'-7" 10'-4" 14'-0" 13'-0"
2'-0"
FEC
FEC
FEC
AREA OF WORK
KEY PLAN
BASEMENT
N
1/4" = 1'-0
4' 8'
GENERAL NOTES:
1. SEE SHEET A-001 FOR ABBREVIATIONS, INDICATION
OF MATERIALS, SYMBOLS, GENERAL NOTES, LEGEND,
CODE DATA & PROJECT INFORMATION.
2. PROVIDE BLOCKING FOR ALL WALL MOUNTED
EQUIPMENT.
3. TYPICAL PLACEMENT OF PARTITION TYPE S1 SHALL BE
LOCATED
" OFF OF EXISTING WALL SURFACE UNLESS
NOTED OTHERWISE.
4. SEE FINISH SCHEDULE FOR WALL FINISH COLORS.
5. REFER TO MECHANICAL DRAWINGS FOR ALL
MECHANICAL WORK.
6. REFER TO ELECTRICAL DRAWINGS FOR ALL
ELECTRICAL WORK.
7. REFER TO PLUMBING DRAWINGS FOR ALL PLUMBING
WORK.
NEW WORK CODED NOTES:
INFILL PARTITION BELOW TO MATCH AND ALIGN
EXISTING PARTITION.
EXISTING WINDOWS ABOVE TO REMAIN, INSTALL
BAR-GRILLE AT INSIDE FACE.
SERVER RACKS TO ALIGN WITH OUTERMOST FULL
FLOOR TILE AS SHOWN ON PLAN. SERVER RACKS
TO BE FURNISHED AND INSTALLED BY OTHERS.
AISLE END DOOR SYSTEM (AEDS). INSTALLER OF
RACK SHALL REMOVE 2'-0" RETURN PANEL
SUPPORTS AND SECURE DOORS TO RACK WITH
SAME ATTACHMENTS.
2' x 2' - 1 HOUR RATED ACCESS PANEL BELOW RAF, TO ACCESS ELEC. PANEL IN CRAWL SPACE BELOW
ADJACENT ROOM. COORD. W/ RAF SUPPORTS AND
EQUIP. SUPPORTS TO ACCOMMODATE 120 DEGREE
SWING. LOCATE PANEL 3" ABOVE CONCRETE
FLOOR.
(2) 34" x 20" OPENINGS W/ FIRE DAMPER CURTAIN.
LOCATE (1) BELOW RAF & (1) ABOVE ACT.
CORNER GUARD @ OUTSIDE CORNERS, TYP.
CONCRETE LEVELING SLAB, SEE 5/A-401 AND
10/A-401
NEW WORK SYMBOLS:
ALL NEW EQUIPMENT AND FURNITURE
INDICATED ON PLANS WITH DASHED
LINES FOR REFERENCE & INFORMATION
ONLY. THESE ARE OWNER FURNISHED
OWNER INSTALLED (O/O)
SCOPE OF WORK
EXISTING PARTITION TO REMAIN
EXISTING DOOR TO REMAIN
NEW DOOR
NEW PARTITION
AS DM
BASEMENT NEW WORK PLAN
ARCHITECTURE
A 1 01
2' - 0" X 2' - 0" RAISED ACCESS FLOOR
SCALE: 1/8" SCALE
BASEMENT NEW WORK PLAN
SCALE: 1/4" SCALE
EXTERIOR GENERATOR PAD - NEW WORK PLAN
FLOOR GRATE SUPPLY AIR
1' - 0" X 1' - 0" VCT FLOOR
FIRE EXTINGUISHER CABINET
FEC
A-301
A-301
16' - VIF
V I F
M A
T C
H
R
A F
PAINTED CONCRETE
A-401
AREA OF WORK
KEY PLAN
BASEMENT
AS DM
BASEMENT REFLECTED
CEILING PLAN
ARCHITECTURE
A 1 10
GENERAL RCP NOTES
CEILING PLAN LEGEND
NEW WORK CODED NOTES
R-1 GRILLES
NEW GYPSUM BOARD
EXISTING WINDOWS TO REMAIN, INSTALL
BAR-GRILLE AT INSIDE FACE
NEW 2' X 2' ACOUSTICAL CEILING
(ACT)
RETURN AIR REGISTER/GRILLE
TRANSFER AIR REGISTER/GRILLE
EXHAUST AIR REGISTER
1. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR
FIXTURE TYPES, SYMBOLS AND SCHEDULES.
2. PROVIDE SPRINKLERS AS SPECIFIED. ALL SPRINKLER
HEADS SHALL BE CENTERED IN CEILING TILE.
3. COMMUNICATION DEVICES AND CEILING MOUNTED
EQUIPMENT SHALL BE CENTERED IN CEILING TILE,
UNO.
4. SEE SHEET A-401 FOR TYPICAL CEILING TRANSITION
DETAILS
5. CEILING GRID ALIGNMENT SHALL MATCH RAF.
6. SEE ROOM FINISH SCHEDULE FOR CEILING TYPE AND
FINISH.
7. CEILING HEIGHTS ARE 8'-6" AFF, U.N.O.
2' X 2' LIGHT FIXTURE
N
1/4" = 1'-0
4' 8'
SCALE: 1/4" SCALE
BASEMENT REFLECTED CEILING PLAN
HOT AISLE CONTAINMENT SYSTEM (HACS)
ATTACHED TO ACT METAL SUSPENSION SYSTEM
LOCATED BETWEEN TOP OF RACK & BOTTOM OF
CEILING. VINYL CURTAIN SHALL BE INSTALLED
FULL HEIGHT FROM CEILING TO FLOOR TO ALLOW
FOR SYSTEM TESTING PRIOR TO INSTALLATION
OF SERVER RACKS. OWNER PERSONNEL TO CUT
CURTAIN TO FIT RACK PER MANUFACTURER'S
PROCEDURES UPON COMPLETION OF RACK
INSTALLATION.
COORDINATE BULKHEAD TO CONCEAL EXISTING
PIPE. VERIFY DIMS. IN FIELD
SCOPE OF WORK
PENDANT LIGHT
(2) 34" x 20" OPENINGS W/ FIRE DAMPER CURTAIN.
LOCATE (1) BELOW RAF & (1) ABOVE ACT.
PENDANT LIGHT
COURTYARD
MAIL ROOM
CORRIDOR
AISLE END DOOR
SYSTEM (AEDS)
SERVER RACK
EXISTING WINDOW
COLUMN BEYOND
RAISED ACCESS FLOOR
NEW CONDENSING UNIT ON
PRE-MANUFACTURED
CURB, SEE MECH.
SEAL CONCRETE
FLOOR BELOW RAF
SUB-BASEMENT
HOT AISLE CONTAINMENT
SYSTEM (HACS)
EXISTING PIPE TO REMAIN
A-401
A-401
A-401
A-401
A-401
RAISED ACCESS FLOOR
EXISTING WINDOWS
VERTICAL BAR-GRILLE
ACCESS PANEL
AREA OF WORK
KEY PLAN
BASEMENT
N
00 2' 4'
3/8" = 1'-0
SECTION 1
SCALE: 3/8" SCALE
AS DM
SECTIONS
ARCHITECTURE
A 3 01
SECTION 2
SCALE: 3/8" SCALE
5/8" GYP. BD ON METAL STUD
EXISTING WINDOW
VERTICAL BAR GRILLE,
REFER TO SPECIFICATION
055963 DETENTION ENCLOSURE
EXISTING WALL ASSEMBLY
SEE PARTITION SCHEDULE
EXISTING WINDOW
NEW SHAFT WALL ASSEMBLY SEE
PARTITION SCHEDULE
VERTICAL BAR GRILLE
MDF SILL, PAINTED
SHIM
FRT BLOCKING
EXISTING WALL ASSEMBLY
5/8" 2 1/2"
1/2"
WOOD TRIM, PAINTED
ACOUSTIC CEILING
2-1/2" METAL STUD
FRAME
COLUMN BEYOND
5/8" GWB RETURN 6" MIN.
NEW WALL ASSEMBLY,
SEE PARTITION SCHEDULE
CUT PANEL TO WITHIN
1/16" OF WALL
PERIMETER PEDESTAL
SHALL PROVIDE
SUPPORT FOR PANELS
AROUND COLUMNS, AT
WALLS AND IN
CORNERS.
SCHEDULED WALL BASE
CONTINUOUS VINYL
CURTAIN FOR HACS
ALUMINUM CEILING
CONNECTION FOR HACS
CEILING SUSPENSION
SYSTEM
ACOUSTIC CEILING PANEL
EXISTING CONC. PAD
EXISTING 3" INSULATION
EXISTING TOPPING SLAB
EXISTING WATERPROOFING
EXISTING CONC. STRUCT.
NEW CONC. PAD, MATCH
EXIST. THICKNESS
3" POLYSTYRENE
INSULATION TO MATCH
EXISTING
COMPRESSIBLE FILL
EXIST. CONC. DRIVING
SURFACE
SEE ARCH.
PLANS FOR EXTENTS
NOTE:
REFER TO STRUCTURAL DRAWINGS FOR REINFORCING
NEW PARTITION BEYOND
CONCRETE LEVELING SLAB
RUBBER TRANSITION STRIP,
ADHERE TO CONCRETE
FLOOR
RAISED ACCESS FLOOR
FLOOR FINISH TO MATCH RAF
2" x 2" x 1/4" CONTINUOUS
STL. ANGLE AT DOOR
OPENINGS
1/2" EXP. BOLT @ 6" O.C.
SCHEDULED DOOR FRAME
MTL THRESHOLD
EXISTING FLOOR &
STRUCTURE
3" x 3" x 1/4" CONTINUOUS
STL. ANGLE
A-701
A-401
METAL COPING
CONTINUOUS METAL CLEAT
NEW ROOFING
COMPATIBLE W/ EXISTING
ROOF MEMBRANE.
CONTRACTOR TO SUBMIT
CONFIRMATION OF
COMPATIBILITY BY ROOF
INSTALLER.
REMOVE PORTION OF
EXIST. INSULATION TO
ALLOW PREFABRICATED
CURB TO ATTACH TO
STRUCT.
TEMPORARILY REMOVE
INSULATION TO ALLOW FOR
NEW ROOFING - OVERLAP
EXISTING 1'-0" MIN. ALL SIDES
EXISTING INSULATION
EXISTING ROOF STRUCT.
PRE-FABRICATED METAL
EQUIPMENT CURB, REFER
TO MECH. SPECIFICATION
FOR MORE INFORMATION
NOTE:
EQUIPMENT TO BE SEISMICALLY BRACED
STL. PL. CAP W/
ATTACHED PIPE INSERT
IN BOLLARD
CONCRETE FILL
8 1/2" DIAMETER PIPE
BOLLARD
STL. BASE PLATE
ANCHOR BOLTS
NOTE:
NEW PIPE BOLLARD TO MATCH EXISTING
S.S. CORNER GUARD
METAL STUD FRAMING
NEW DRAIN PIPE
SCHEDULED PARTITION
CONCRETE LEVELING SLAB
RUBBER TRANSITION STRIP,
ADHERE TO CONCRETE
FLOOR
FLOOR FINISH TO MATCH RAF
2" x 2" x 1/4" CONTINUOUS
STL. ANGLE AT DOOR
OPENINGS
1/2" EXP. BOLT @ 6" O.C.
3" x 3" x 1/4" CONTINUOUS
STL. ANGLE
NEW PARTITION BEYOND
AREA OF WORK
KEY PLAN
BASEMENT
N
00 2' 4'
3/8" = 1'-0
WINDOW HEAD DETAIL
SCALE: 3" SCALE
AS DM
DETAILS
ARCHITECTURE
A 4 01
WINDOW SILL DETAIL
SCALE: 3" SCALE
DETAIL @ BULKHEAD
SCALE: 3" SCALE
RAF DETAIL
SCALE: 3" SCALE
VINYL CURTAIN CONNECTION DETAIL
SCALE: 6" SCALE
EXTERIOR EQUIPMENT PAD MODIFICATION
SCALE: 3" SCALE
DOOR TRANSITION DETAIL @ CORRIDOR
SCALE: 1-1/2" SCALE
EXTERIOR EQUIPMENT PAD MODIFICATION
SCALE: 3" SCALE
DETAIL @ EXISTING PIPE FURRING
SCALE: 3" SCALE
BOLLARD SECTION DETAIL
SCALE: 1-1/2" SCALE
RAF TRANSITION DETAIL
SCALE: 3" SCALE
1 1/2"=1'-0"
CHASE WALL ASSEMBLY
S
TYPICAL PARTITION
A
1 1/2"=1'-0"
TYPE STUD TOTAL WIDTH SAFB RATING UL STC NOTESTYPE STUD TOTAL WIDTH SAFB RATING UL STC NOTES
HEAD
PLAN
BASE
5/8" TYPE "X" GWB
CONT. ACOUSTICAL SEALANT
SCHEDULED WALL BASE
2 1/2" C-H STUD
CEILING WHERE APPLICABLE
UNDERSIDE OF STRUCTURE
CONT. SEALANT
METAL J TRACK
HEAD
PLAN
BASE
5/8" TYPE "X" GWB EACH SIDE
CONT. ACOUSTICAL SEALANT
SCHEDULED WALL BASE
3 5/8" METAL STUD
CEILING WHERE APPLICABLE
UNDERSIDE OF STRUCTURE
CONT. SEALANT
S1 2 1/2"
3 1/8" - 1 HR U415 - EXT. GWB TO UNDERSIDE OF DECK
1 LAYER 5/8" TYPE "X" GWB
A1 3 5/8" 4 7/8" - 1 HR U419 - EXT. GWB TO UNDERSIDE OF DECK
1" LINER PANEL
RAISED ACCESS FLOOR
RAISED ACCESS FLOOR
CONT. DEFLECTION TRACK
CONT. DEFLECTION TRACK
CONT. BOTTOM RUNNER
FURRING WALL
F
1 1/2"=1'-0"
TYPE STUD TOTAL WIDTH SAFB RATING UL STC NOTES
HEAD
PLAN
BASE
5/8" TYPE "X" GWB
CONT. ACOUSTICAL SEALANT
SCHEDULED WALL BASE
2 1/2" METAL STUD
CEILING WHERE APPLICABLE
UNDERSIDE OF STRUCTURE
METAL J TRACK
F1 2 1/2"
3 1/8" - - - - -
1 LAYER 5/8" GWB
CONT. DEFLECTION TRACK
RAISED ACCESS FLOOR
DOOR SCHEDULE
DOOR NO. ROOM NAME
DOOR
TYPE MATERIAL WIDTH HEIGHT
0410A.1
UPS ROOM
0410.3 SERVER RACKS
0418.2 ELECTRICAL ROOM
THICKNESS
FRAME
TYPE MATERIAL JAMB HEAD THRESHOLD
MISC.
FIRE SIGN TYPE
0410.2 SERVER ROOM
HARDWARE
1-1/2"
0418.3 ELECTRICAL ROOM
SUPPLIED BY HOT AISLE CONTAINMENT MANUF.
0410.4 SERVER RACKS
D1
D3
3'-0" (PAIR)
3'-0"
2'-0" (PAIR)
D1
3'-0" 7'-0" 1-3/4"
STEEL
HM
HM
HM 7'-0"
7'-0"
7'-0"
REMARKS
F1 HM
J1
H1 T2
F1 HM J1
H1 T3
1-3/4"
1-3/4"
45 MIN.
45 MIN.
0418.1 ELECTRICAL ROOM D1 1-3/4"
NOTES:
1. ALL ACS DEVICES BY OWNER. GC TO COORDINATE CONDUIT AND BACKBOXES - SEE ELECTRICAL.
2. SIGNAGE TO BE GFCI.
F1
J1 H1
MATCH EXIST.
MATCH EXIST.
MATCH EXIST.
MATCH EXIST.
MATCH EXIST.
HM
SS
SS
HM
HM J1
J1
H1
H1
T1
T1
T2 45 MIN.
45 MIN.
45 MIN.
F1
1-1/2"
1-3/4"
4'-0"
HM 7'-0"
D3
D1 HM
STEEL
3'-0"
2-0" (PAIR)
7'-0"
7'-0"
D2
SERVER ROOM0410.1
D2 HM 3'-0" (PAIR)
1-3/4"
7'-0" F1 J1
HM H1
45 MIN.T1
MATCH EXIST.
3'-0"
PT-4 EXTERIOR, PT-3 INTERIOR
PT-4 EXTERIOR, PT-3 INTERIOR
PT-4 EXTERIOR, PT-3 INTERIOR
PT-4 EXTERIOR, PT-3 INTERIOR
PT-4 EXTERIOR, PT3 INTERIOR
PT-3, BOTH SIDES
7'-0" F1
SUPPLIED BY HOT AISLE CONTAINMENT MANUF.
FLUSH
SINGLE
FLUSH
DOUBLE
D2D1
FRAME TYPES
F1
2" 2"
HOT AISLE
CONTAINMENT
SLIDING DOORS
D3
DOOR TYPES
ROOM FINISH SCHEDULE
DOOR NO. ROOM NAME
0410 SERVER ROOM
ELECTRICAL ROOM
0410A UPS ROOM
FLOOR BASE NORTH SOUTH EAST WEST TYPE FINISH REMARKS
WALLS CEILING
RAF-1
RAF-1
VCT-1
RB-1
RB-1
RB-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
ACT-1
ACT-1
EXPOSED
PT-2
PT-2 AT BULKHEADS
PT-2 AT BULKHEADS
MATERIALS SCHEDULE
RAF-1 TATE INC.
COLOR
RAISED ACCESS FLOOR TO MATCH VCT
ACT-1
ARMSTRONG
PT-1 SHERWIN WILLIAMS
ULTIMA SQUARE LAY-IN
DESCRIPTION
24" X 24" TO MATCH TILE SIZE INTEGRAL W/ RAF PANEL
RB-1 ARMSTRONG
FLATPT-2 SHERWIN WILLIAMS
SW7004 SNOWBOUND
12 SHADOW GRAYSTRAIGHT
PAINT
RUBBER WALL BASE
PT-3 SHERWIN WILLIAMS SEMI-GLOSS
NOTES:
1. PRODUCT MANUFACTURERS REFERENCED ARE INTENDED TO ESTABLISH COLOR AND FINISH ONLY AND ARE NOT INTENDED TO LIMIT SELECTIONS FROM
OTHER MANUFACTURERS.
24" X 24" X 3/4"
EGGSHELL
ULTIMA SQUARE LAY-IN
SW7004 SNOWBOUNDPAINT
ACOUSTIC CEILING TILE
PAINT
1910 WHITE
SW7004 SNOWBOUND
ARMSTRONGVCT-1
VINYL COMPOSITE TILE WHITE OUT 57518
STANDARD EXELON IMPERIAL TEXTURE
12" X 12" X 1/8"
MAT. CODE MFGR.MATERIAL
STLYE/FINISH
SEMI-GLOSS
PT-4 SHERWIN WILLIAMS BEIGE TO MATCH EXIST.PAINT
SCHEDULED DOOR
MTL THRESHOLD
AUTO DOOR BOTTOM SCHEDULED DOOR
FLOOR FINISH AS SCHEDULED
RUBBER THRESHOLD
SEALANT BOTH SIDES -
SEE PARTITION
REQUIREMENTS
SEE PTN. SCHED.
1/2"
DOUBLE METAL STUD
ANCHOR CLIPS
SEALANT - BOTH SIDES
S E
E
P
T N
S
C H
E D
2"
SCHEDULED DOOR
MTL THRESHOLD
AREA OF WORK
KEY PLAN
BASEMENT
1/4" = 1'-0
4' 8'
AS DM
SCHEDULES & TYPICAL
DETAILS
ARCHITECTURE
A 7 01
THRESHOLD DETAIL
SCALE: 3" SCALE
THRESHOLD DETAIL
SCALE: 3" SCALE
T2T1 HEAD DETAIL
SCALE: 3" SCALE
JAMB DETAIL
SCALE: 3" SCALE
J1 H1
THRESHOLD DETAIL
SCALE: 3" SCALE
T3
AutoCAD SHX Text
.DWG
AutoCAD SHX Text
CADD FILE
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
NAME
AutoCAD SHX Text
STREET: 14TH & INDEPENDENCE AVE. S.W.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CKD. BY
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
SERIES
AutoCAD SHX Text A-E
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
SOLICITATION
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SEQUENCE
AutoCAD SHX Text
CITY: WASHINGTON , DISTRICT OF COLUMBIA
AutoCAD SHX Text
PROGRESS DATE
AutoCAD SHX Text
USDA NUMBER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
SOUTH BUILDING
AutoCAD SHX Text
ROOM 0410
AutoCAD SHX Text
DC0005ZZ
AutoCAD SHX Text
THE DEPARTMENT OF AGRICULTURE
AutoCAD SHX Text
AG-3412-C-16-0008
AutoCAD SHX Text
2017-EB-1
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
ABATEMENT
AutoCAD SHX Text
PLANNING
AutoCAD SHX Text
DATA CENTER CONVERSION
AutoCAD SHX Text
USDA FIRE
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
TELECOM
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
CONTRACTING
AutoCAD SHX Text
OFFICER
AutoCAD SHX Text Ken was here
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AECOM#60535380
AutoCAD SHX Text
HISTORIC
AutoCAD SHX Text
PRESERVATION
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
AECOM TECHNICAL SERVICES, INC.
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
COVER SHT. APPROVALS
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
GSA FIRE
AutoCAD SHX Text
CONCESSIONS
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
MANAGEMENT
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text
2020 K ST NW, WASHINGTON DC
AutoCAD SHX Text
AECOM TECHNICAL SERVICES
AutoCAD SHX Text 8/08/2017
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 7/21/2017
AutoCAD SHX Text
ADDENDUM 1
AutoCAD SHX Text 9/12/2017
EXISTING PIPE
EXISTING PIPE AND SPRINKLER TO BE REMOVED
NEW PIPE
PIPE DOWN
PIPE UP / PIPE UP & DOWN
PIPE CONTINUATION
PIPE END CAP
UPRIGHT SPRINKLER
CONCEALED TYPE SPRINKLER
PENDENT SPRINKLER
INDICATING CONTROL VALVE WITH TAMPER SWITCH
CHECK VALVE
WATER FLOW SWITCH
DRAIN CONNECTION
LIMIT OF DEMOLITION
LIMIT OF NEW WORK
SYMBOLS
SPRINKLER FLOOR CONTROL ASSEMBLY
FIRE DEPARTMENT CONNECTION
GALLONS PER MINUTE
HAZARD CATEGORY 1
HAZARD CATEGORY 2
POUNDS PER SQUARE INCH
SPRINKLER
FIRE HYDRANT
NOT TO SCALE
ABBREVIATIONS
FCA
FDC
GPM
HC-1
HC-2
PSI
SP
FH
NTS
PROVIDE ALL NECESSARY PARTS, ACCESSORIES AND LABOR TO
INSTALL A NEW AND COMPLETE SPRINKLER SYSTEM, AS REQUIRED.
CONTRACTOR SHALL PROVIDE SPRINKLER SYSTEM SHOP
DRAWINGS IN ACCORDANCE WITH NFPA 13 SIGNED AND SEALED
BY A PROFESSIONAL ENGINEER. PROVIDE PRODUCT DATA FOR
MATERIALS AND EQUIPMENT, PRELIMINARY TEST FORMS, FINAL
ACCEPTANCE TEST FORMS, FIRE PROTECTION SPECIALIST
QUALIFICATIONS, SPRINKLER SYSTEM INSTALLER QUALIFICATIONS,
AND INSTALLATION DETAILS OF SPECIAL CONDITIONS, AND SUBMIT
TO THE AUTHORITY HAVING JURISDICTION FOR REVIEW. NO WORK
SHALL…
This is the start of the file's text. The full file is on GovTribe.